Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRONIC GUIDANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

The Evolution of Airport Terminal Wayfinding Technologies

This work was presented during the Transportation Research Board (TRB) and Airport Cooperative Research Program (ACRP) webinar "Enhancing the Airport Experience with Wayfinding" on May 23, 2024. The process of navigating within airports has evolved over the years, with various technologies emerging to complement static signage. Historically, wayfinding began with static signage and airport staff members providing personal guidance, before progressing into digital signs, interactive kiosks, and displays. In recent years, wayfinding has continued along its digital path using mobile applications, indoor positioning technology, and even robot guides. With ever- larger airport facilities and a growing number of travelers, the future of wayfinding will likely be heavily linked to further digital developments such as facial recognition, augmented-reality technology, and autonomous vehicle navigation. This presentation delves into the history of interior wayfinding in airports, its present state, and the anticipated future. Key wayfinding technologies are discussed with an emphasis on emerging smartphone applications. Other considerations such as legal issues, language barriers, and human-technology interactions are included. A wayfinding framework is proposed, with static wayfinding technologies serving as the base upon which dynamic and personalized digital technologies are built. In this framework, electronic wayfinding technologies do not replace - but rather augment - traditional methods. These technologies can be integrated into existing wayfinding systems for a seamless traveler experience.

airport↗

Probing Oxidation-Driven Amorphized Surfaces in a Ta(110) Film for Superconducting Qubit

Recent advances in superconducting qubit technology have led to significant progress in quantum computing, but the challenge of achieving a long coherence time remains. Despite the excellent lifetime performance that tantalum (Ta) based qubits have demonstrated to date, the majority of superconducting qubit systems, including Ta-based qubits, are generally believed to have uncontrolled surface oxidation as the primary source of the two-level system loss in two-dimensional transmon qubits. Therefore, atomic-scale insight into the surface oxidation process is needed to make progress toward a practical quantum processor. Here, in this study, the surface oxidation mechanism of native Ta films and its potential impact on the lifetime of superconducting qubits were investigated using advanced scanning transmission electron microscopy (STEM) techniques combined with density functional theory calculations. The results suggest an atomistic model of the oxidized Ta(110) surface, showing that oxygen atoms tend to penetrate the Ta surface and accumulate between the two outermost Ta atomic planes; oxygen accumulation at the level exceeding a 1:1 O/Ta ratio drives disordering and, eventually, the formation of an amorphous Ta 2 O 5 phase. In addition, we discuss how the formation of a noninsulating ordered TaO 1–δ (δ < 0.1) suboxide layer could further contribute to the losses of superconducting qubits. Subsurface oxidation leads to charge redistribution and electric polarization, potentially causing quasiparticle loss and decreased current-carrying capacity, thus affecting superconducting qubit coherence. The findings enhance the comprehension of the realistic factors that might influence the performance of superconducting qubits, thus providing valuable guidance for the development of future quantum computing hardware.

36 MATERIALS SCIENCE↗

TH-B-BRC-03: Measurement and Calibration Discrepancy: Advanced Warning Guidance

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

Are Current SEE Test Procedures Adequate for Modern Devices and Electronics Technologies?

Believe it or not, this has been a simplistic look at starting a checklist for SEE testing. Given a memory that has 68 operating modes, when a SEU occurs that changes the mode, just how do you determine what's going on? Laser and microbeam tests can help, but not easily for modern packaged devices. Expanding this approach to other more complex devices such as ADCs or processors as well as analog devices should be considered. The recommendation is to use the existing text standards as the starting point. Just make your own checklist for the device/technology/issues being considered. At HEART 2007, we presented some of the burgeoning challenges associated with single event effect(SEE) testing of modern commercial memories: a) Package, device complexity, test fixture, and data analysis issues were discussed; b) "Complete" SEE Characterization would take 15 years; c) Qualification test costs have a greater than 4 times increase over the last decade. In this talk, we continue to explore the roles of technology with an emphasis on the existing SEE Test Procedures and some of the concerns related to modern devices. The primary objective of the briefing is to provide some overarching guidance concerning the many considerations involved in the formulation of a SEE test plan provided in a " Checklist" format.we note that there is no such thing as a complete check list and that the best approach is to develop a flexible test plan that takes into account the device type and functions, the device technology, circuit and package design, and, of course, test facility and beam characteristics.

LaBel, Kenneth A.↗

The Interventional Radiology (IR) Gender Gap: A Prospective Online Survey by the Cardiovascular and Interventional Radiological Society of Europe (CIRSE)

AimA prospective online survey was conducted by the Cardiovascular Interventional Radiological Society of Europe (CIRSE) to evaluate the gender gap within interventional radiology (IR) and the barriers facing women in IR.Materials and MethodsA questionnaire (“Appendix”) was devised by the authors and the CIRSE communication and publication team and sent electronically to 750 identifiable female members of CIRSE. Responses were collected from 7 August to 24 August 2017.ResultsThe response rate was 19.9% (n = 149) with highest responses from UK (18%), Italy (11%), Germany (11%), Spain (7%), Netherlands (5%), France (5%), Sweden (4%), USA (4%). 91% of the respondents were between 31 and 46 years, 83% work full time, 62% spend > 50% of their working time in IR, and 67% practice in a university or tertiary referral institution. 85% were in the minority in their department. 52% had no leadership role in their department, but 67% expressed willingness to consider a leadership position. Their main concerns were work/family life balance, the risks of radiation exposure, the effect of pregnancy on training and practice and the male-dominated work environment.ConclusionThis survey highlights issues experienced by women in IR. Clear guidance on concerns regarding radiation exposure particularly during pregnancy is needed. Structured and supportive training is required for female IRs who may wish to train or work flexibly. The male-dominated environment is discouraging, and a scheme to promote female IRs would encourage women to take on senior leadership positions and attract more women into the specialty.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Evolution of Wayfinding Within Airports

The process of navigating within airports has evolved over the years, with various technologies emerging to complement static signage. Historically, wayfinding began with static signage and airport staff members providing personal guidance, before progressing into digital signs, interactive kiosks, and displays. In recent years, wayfinding has continued along its digital path using mobile applications, indoor positioning technology, and even robot guides. With ever- larger airport facilities and a growing number of travelers, the future of wayfinding will likely be heavily linked to further digital developments such as facial recognition, augmented-reality technology, and autonomous vehicle navigation. This report delves into the history of interior wayfinding in airports, its present state, and the anticipated future. Key wayfinding technologies are discussed in detail, with an emphasis on emerging smartphone applications. Other considerations such as traveler stress, legal issues, pandemic safety, and language barriers are included. A wayfinding framework is proposed, with static wayfinding technologies serving as the base upon which dynamic and personalized digital technologies are built. In this framework, electronic wayfinding technologies do not replace - but rather augment - traditional methods. These technologies can be integrated into existing wayfinding systems for a seamless traveler experience.

ADVANCED PROPULSION SYSTEMS↗

FEFF analysis of americium oxides

The Am N 4,5 (4d 3/2 and 4d 5/2 ) and Am O 4,5 (5d 3/2 and 5d 5/2 ) x-ray absorption spectroscopy (XAS) of americium sesquioxide (Am 2 O 3 ) and americium dioxide (AmO 2 ) has been evaluated with FEFF, a Green's function–based, multiple scattering code. Taking guidance from the intermediate coupling model (ICM), applicable to local and nonmagnetized samples, it is possible to completely reconstruct the experimental results for the N 4,5 spectra, including the observed differences between the Am 2 O 3 and the AmO 2 cases. Although complicated by a more asymmetric line shape and difficult background variations, the FEFF analysis confirms the absence of core hole angular momentum coupling in Am O 4,5 spectroscopy.

36 MATERIALS SCIENCE↗

Understanding the origin of high-rate intercalation pseudocapacitance in Nb 2 O 5 crystals

Pseudocapacitors aim to maintain the high power density of supercapacitors while increasing the energy density towards those of energy dense storage systems such as lithium ion batteries. Recently discovered intercalation pseudocapacitors (e.g. Nb 2 O 5 ) are particularly interesting because their performance is seemingly not limited by surface reactions or structures, but instead determined by the bulk crystalline structure of the material. We study ordered polymorphs of Nb 2 O 5 and detail the mechanism for the intrinsic high rates and energy density observed for this class of materials. We find that the intercalating atom (lithium) forms a solid solution adsorbing at specific sites in a network of quasi-2D NbO x faces with x {1.3, 1.67, or 2}, donating electrons locally to its neighboring atoms, reducing niobium. Open channels in the structure have low diffusion barriers for ions to migrate between these sites (Eb 0.28 0.44 eV) comparable to high-performance solid electrolytes. Using a combination of complementary theoretical methods we rationalize this effect in Li x Nb 2 O 5 for a wide range of compositions (x) and at finite temperatures. Multiple adsorption sites per unit-cell with similar adsorption energies and local charge transfer result in high capacity and energy density, while the interconnected open channels lead to low cost diffusion pathways between these sites, resulting in high power density. The nano-porous structure exhibiting local chemistry in a crystalline framework is the origin of high-rate pseudocapacitance in this new class of intercalation pseudocapacitor materials. As a result, this new insight provides guidance for improving the performance of this family of materials.

36 MATERIALS SCIENCE↗

Understanding the role of NH 4 F and Al 2 O 3 surface co-modification on lithium-excess layered oxide Li 1.2 Ni 0.2 Mn 0.6 O 2

In this work we prepared Li 1.2 Ni 0.2 Mn 0.6 O 2 (LNMO) using a hydroxide co-precipitation method and investigated the effect of co-modification with NH 4 F and Al 2 O 3 . After surface co-modification, the first cycle Coulombic efficiency of Li 1.2 Ni 0.2 Mn 0.6 O 2 improved from 82.7% to 87.5%, and the reversible discharge capacity improved from 253 to 287 mAh g –1 at C/20. Moreover, the rate capability also increased significantly. A combination of neutron diffraction (ND), high-resolution transmission electron microscopy (HRTEM), aberration-corrected scanning transmission electron microscopy (a-STEM)/electron energy loss spectroscopy (EELS), and X-ray photoelectron spectroscopy (XPS) revealed the changes of surface structure and chemistry after NH 4 F and Al 2 O 3 surface co-modification while the bulk properties showed relatively no changes. These complex changes on the material s surface include the formation of an amorphous Al 2 O 3 coating, the transformation of layered material to a spinel-like phase on the surface, the formation of nanoislands of active material, and the partial chemical reduction of surface Mn 4+ . Such enhanced discharge capacity of the modified material can be primarily assigned to three aspects: decreased irreversible oxygen loss, the activation of cathode material facilitated with preactivated Mn 3+ on the surface, and stabilization of the Ni-redox pair. In conclusion, these insights will provide guidance for the surface modification in high-voltage-cathode battery materials of the future.

36 MATERIALS SCIENCE↗

Bubble explosion induced melt pool instabilities in electron beam melting of aluminum alloy

Electron beam melting (EBM) is an additive manufacturing technology that can process materials and manufacture components otherwise impossible or uneconomical. However, defects, including porosity and surface irregularities, are widely reported in EBM-built components, and their formation mechanisms are not fully understood. Here, using in-situ high-speed synchrotron X-ray imaging, we reveal that bubble explosions in Al6061 during EBM induce melt pool instabilities contributing to defect formation. The melt pool and keyhole evolve through three stages: (1) initial formation of a melt pool, (2) subsurface bubble formation and explosion, and (3) periodic keyhole oscillation. During scanning, periodic bubble explosions can eject molten liquid as spatters and disturb the vapor depression and melt pool, contributing to surface humping, that may trigger lack-of-fusion defects in subsequent layers. The physical insights we report could provide guidance for EBM machine development, process innovation, alloy design and model development.

36 MATERIALS SCIENCE↗

SU-F-T-324: Experimental Measurement of Optically Stimulated Luminescence Detectors in a MR-IGRT Environment Toward Assessing Magnetic Field Effects On These Devices and Their Use as An In-Vivo Dosimeter

Purpose: To characterize magnetic field effects on Optically Stimulated Luminescence Detectors (OSLDs) for use as an in-vivo dosimeter in an MRIGRT machine. Methods: Landauer OSLD nano-dots and the MicroStar II reader were used to measure and record OSLDs exposed in and on a solid water phantom in a 10.5 × 10.5 cm{sup 2} field, Co-60, 0.32-Tesla MR-IGRT machine - with and without the presence of the magnetic field. Two orthogonal gantry angles were considered to assess orientation effects on the OSLDs with respect to the incident angle of the radiation beam and magnetic field. The same OSLDs were then used (after readout and bleaching) when the magnetic field was restored. Results: The measured surface dose decreased by 14.1 ± 1.8% when magnetic field was ’on’ due to contamination electrons being swept away by the field. Doses at both 0.5 cm and 5 cm depth increased by 6.5 ± 0.9% and 8.8 ± 0.5% respectively when the magnetic field was present and the OSLDs oriented with their long axis parallel with the incident beam. This contrasts with an increased dose of 2.7 ± 1.1% when the magnetic field was present and the OSLDs were oriented with their long axis perpendicular to the incident beam. Conclusion: Previous works have shown that OSLDs have a dependence on beam incidence angle. Our current work suggests an additional dependence on the presence of the magnetic field when the beam is not perpendicular to the plane of the detector and this effect needs to be considered. Furthermore, the use of an in-vivo dosimeter was shown to have no effect on image quality during the use of MR guidance. Future work will focus on the use of an electromagnet with a linear accelerator to further characterize these effects.

60 APPLIED LIFE SCIENCES↗

Simulation, Challenge Testing and Validation of Solutions for Residential and Commercial Occupancy Sensing/Counting and CO2 Sensing (Final Report)

Carbon dioxide sensors used for monitoring and control applications in buildings are known to be sensitive to long term drift and can be affected by variations in temperature, humidity, other gas interferents, pressure and other factors that cannot be corrected through the typical auto-calibration methods often embedded in the sensor electronics. This investigation was part of the Category D defined in the ARPA-E Saving Energy Nationwide in Structures With Occupancy Recognition (SENSOR) Financial Assistance Funding Opportunity Announcement No. DE-FOA-0001737, FFDA No. 81.135, January 18, 2017. The FOA defined target criteria for the evaluation of the Category C commercial CO2 sensors selected for review and development through the ARPA-E SENSOR program and charged the Iowa State Category D team with developing an evaluation methodology for Category C sensors in accordance with these criteria. As part of the work, the Iowa State team chose to engage the standards community in the development of the evaluation methodology. Standard development work in the D22.05 Indoor Air and D22.03 Ambient Atmospheres and Source Emissions subcommittees of ASTM International Committee D22 on Air Quality on the evaluation of low cost sensors and provision of guidance for using indoor carbon dioxide concentrations to evaluate indoor air quality and ventilation is of particular relevance to the Category D efforts. To date, three draft standards with specific input by the Iowa State Category D team have passed the subcommittee balloting stage and are being balloted in December 2022 and January 2023 in the main D22 committee. In addition to the aforementioned standards to which the PI was a contributing author, intellectual property developed in this project pertaining to “An Automated System for Evaluation of the Long Term Performance of Carbon Dioxide Sensors” and “An Automated Ground Truth System for Real-Time Reliability Assessment, Capture of Control Decisions and Energy Savings Measurements for Occupancy Recognition Systems and Other Applications” are the other major deliverables of the project. These standards and the developed intellectual property are expected to benefit the public in a number of ways stemming from their provision of means to benchmark the performance of carbon dioxide and other sensor systems. In particular, there is high interest in techniques to demonstrate the performance of low-cost carbon dioxide sensors which can be used for typical HVAC applications (e.g., demand controlled ventilation, outdoor and indoor air monitoring, estimation of occupancy, etc.).

42 ENGINEERING↗

Ensuring electromagnetic compatibility in grid-connected power converters: Challenges, standards, and compliance strategies

In today's rapidly advancing world, electronic devices and systems are fundamental to a wide range of industries, including renewable energy and global telecommunications infrastructure. However, as these devices become more complex and widespread, the risk of electromagnetic interference (EMI) also increases, underscoring the importance of stringent Electromagnetic Compatibility (EMC) requirements for maintaining system integrity. This paper addresses the specific challenges associated with grid-connected power converters (GCPCs), which are critical in integrating renewable energy into existing power grids. It explores the complexities of EMI in the context of GCPCs, particularly given the recent emergence of tailored EMC standards for these systems. The paper also highlights the shortcomings of applying generic or unrelated standards to GCPCs, often leading to inadequate compliance and testing protocols. Through a detailed analysis of existing standards and recent advancements in product-specific EMC requirements, this paper provides a comprehensive overview of the current landscape, offering guidance to stakeholders on navigating the intricate EMC compliance landscape, with a focus on methodologies, testing procedures, and the evolving regulatory environment for GCPCs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New Gear Transmission Error Measurement System Designed

The prime source of vibration and noise in a gear system is the transmission error between the meshing gears. Transmission error is caused by manufacturing inaccuracy, mounting errors, and elastic deflections under load. Gear designers often attempt to compensate for transmission error by modifying gear teeth. This is done traditionally by a rough "rule of thumb" or more recently under the guidance of an analytical code. In order for a designer to have confidence in a code, the code must be validated through experiment. NASA Glenn Research Center contracted with the Design Unit of the University of Newcastle in England for a system to measure the transmission error of spur and helical test gears in the NASA Gear Noise Rig. The new system measures transmission error optically by means of light beams directed by lenses and prisms through gratings mounted on the gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. A photodetector circuit converts the light to an analog electrical signal. To increase accuracy and reduce "noise" due to transverse vibration, there are parallel light paths at the top and bottom of the gears. The two signals are subtracted via differential amplifiers in the electronics package. The output of the system is 40 mV/mm, giving a resolution in the time domain of better than 0.1 mm, and discrimination in the frequency domain of better than 0.01 mm. The new system will be used to validate gear analytical codes and to investigate mechanisms that produce vibration and noise in parallel axis gears.

Oswald, Fred B.↗

Fluorination‐Enhanced Surface Stability of Disordered Rocksalt Cathodes

Abstract Cation‐disordered rocksalt (DRX) oxides are a promising new class of high‐energy‐density cathode materials for next‐generation Li‐ion batteries. However, their capacity fade presents a major challenge. Partial fluorine (F) substitution into the oxygen (O) lattice appears to be an effective strategy for improving the cycling stability, but the underlying atomistic mechanism remains elusive. Here, using a combination of advanced transmission electron microscopy based imaging and spectroscopy techniques, the structural and chemical evolution upon cycling of Mn‐based DRX cathodes with an increasing F content (Li–Mn–Nb–O–F x , x = 0, 0.05, 0.2) are probed. The atomic origin behind the beneficial effect of high‐level fluorination for enhancing the surface stability of the DRX is revealed. It is discovered that, due to the reduced O redox activity while with increasing F concentration, F in the DRX lattice mitigates the formation of an O‐deficient surface layer upon cycling. For low F‐substituted DRX, the O loss near the surface results in the formation of an amorphous cathode–electrolyte interphase layer and nanoscale voids after extended cycling. Increased F concentration in the DRX lattice minimizes both O loss and the interfacial reactions between DRX and the liquid electrolyte, enhancing the surface stability of DRX. These results provide guidance on the development of next‐generation cathode materials through anion substitution.

Li, Linze↗

Influence of surface chemistry on Li nucleation energetics on graphene-based surfaces

Lithium metal is a promising high-capacity anode material for solid-state batteries, but it typically suffers from poor cyclability. Carbon scaffold hosts have the potential to improve this performance due to their high electronic conductivity and large surface area, which facilitates lithium-ion adsorption and desorption. Scaffold surface chemistry is known to significantly influence performance outcomes, but the details of these interactions are not fully understood. Here, this study employs first-principles simulations to explore lithium transport and nucleation on graphene anodes with various surface chemistries. Using enhanced sampling techniques, ab initio molecular dynamics, and density functional theory calculations, we find that although surface chemistry has a minimal impact on lithium interfacial transport, it influences surface nucleation significantly. Both heteroatom dopants and intrinsic defects lower the nucleation barrier, creating a more favorable environment for lithium nucleation compared to pristine graphene. In addition, our results reveal a complex interplay between surface lithium concentration, lithium transport, and nucleation kinetics. These findings highlight the potential of surface modifications to precisely control nucleation processes on carbon-based anodes and provide design guidance for reducing dendrite formation and improving the cycle life of solid-state batteries.

36 MATERIALS SCIENCE↗

TH-C-204-00: Medical Physics Workshop: An Update On the Journal’s Improvement Activities and Guidance On Writing and Reviewing Papers

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

TH-C-204-01: Vision for Medical Physics and Status of Current Initiatives

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗