Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fermilab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Latest results of the Muon g-2 experiment at Fermilab

The muon magnetic anomaly, aμ = g - 2/ 2, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. The Muon g − 2 experiment at Fermilab aims to measure aμ with a final accuracy of 140 parts per billion (ppb). The experiment is based on the measurement of the muon spin anomalous precession frequency, ωa, in a magnetic field. The first result of the experiment, based on the 2018 data-taking campaign, was published in 2021 and it confirmed the previous result obtained at Brookhaven National Laboratory with a similar sensitivity of 460 ppb. In this proceeding, the result based on the 2019 and 2020 datasets is presented and the improvement in the accuracy with respect to the 2018 dataset are discussed.

Sorbara, Matteo [INFN, Rome2; Rome U., Tor Vergata↗

Cryogenic Infrastructure Upgrade of the Fermilab Magnet and Vertical Cavity Test Facilities

The Fermilab Magnet Test Facility (MTF) and the Vertical Cavity Test Facility (VCTF), both located in Industrial Building 1 and serviced by a shared cryogenic infrastructure, provide cryogenic testing of superconducting magnets and superconducting radio‐frequency cavities in support of programs such as the Tevatron, US‐LHC, LARP, HINS, Project X, and the ILC. While MTF must continue to support a robust magnet test program, VCTF is expected to increase its cavity test throughput by a factor of five, reaching 250 cavity test cycles per year as cavity production ramps up. A cryogenic infrastructure upgrade program has been undertaken in preparation for meeting the challenge of this additional cavity test throughput. The cryogenic infrastructure improvements include dedicated ambient temperature vacuum pumps, a helium compressor, purification skids, and additional helium gas storage. This paper will elaborate on the goals of the upgrade program, the selected equipment, and foreseen integration and operations plans and issues.

Rabehl, R.↗

High brightness gamma-ray production at Fermilab Accelerator Science and Technology (FAST) facility

Electron beams with energies of the order of a few 100's of MeV and low transverse emittance, in combination with powerful infrared lasers, allow for the production of high quality gamma rays through Inverse Compton Scattering (ICS). At Fermilab Accelerator Science and Technology (FAST) facility, a 300 MeV beam will be used to generate gamma rays with maximum photon energies of up to ~1.5 MeV and brightness of the order of 10 21 photons/[s-(mm-mrad) 2- 0.1%BW]. Due to the low electron-beam transverse emittance, the relative bandwidth of the scattered radiation is expected to be ≤ 1%. A key challenge toward the production of high radiation dose and brightness is to enhance the energy of the infrared 3 ps laser pulses to the joule level. Finally, in this contribution, we present the plans for the experimental setup, along with comprehensive numerical simulations of the ICS process.

43 PARTICLE ACCELERATORS↗

Record high-gradient SRF beam acceleration at Fermilab

Here, many modern and future particle accelerators employ high gradient superconducting RF (SRF) to generate beams of high energy, high intensity and high brightness for research in high energy and nuclear physics, basic energy sciences, etc. In this paper we report the record performance large-scale SRF system with average beam accelerating gradient matching the International Linear Collider (ILC) specification of 31.5 MV m –1 . Design of the eight cavity 1.3 GHz SRF cryomodule, its performance without the beam and results of the system commissioning with high intensity electron beam at Fermilab Accelerator Science and Technology (FAST) facility are presented. We also briefly discuss opportunities for further beam studies and tests at FAST including those on even higher gradient and more efficient SRF acceleration, as well as exploration of the system performance with full ILC-type beam specifications.

43 PARTICLE ACCELERATORS↗

Taking global scale data handling to the Fermilab intensity frontier

SAM is a comprehensive data management system used by the Tevatron Run II experiments with great success. The newest experiments at Fermilab, the Intensity Frontier experiments, are currently lacking such a system. In these proceedings, the advantages of using SAM for these experiments is discussed. Two improvements to SAM, namely SAMWeb and SAMfs are described. These improvements will make SAM much easier to integrate, deploy, maintain, and use.

Lyon, Adam L.↗

Synchronization of the 14 kTon NO$\nu$A neutrino detector with the Fermilab NuMI beam

The NOνA experiment is a neutrino oscillation experiment designed to measure parameters related to the neutrino mixing matrix, mass hierarchy and CP violation. The experiment measures neutrino and anti-neutrino interactions from the NuMI beam line at Fermilab in a Near Detector and a Far Detector located 810 kilometers away. Making these measurements requires precise synchronization of 344,064 channels in the Far Detector to an absolute wall time with a channel to channel variation of less then 10 ns. The experiment must correlate the presence of the relatively narrow neutrino beam in the detector with data readout. This paper will discuss the performance of the NOνA timing system during the first few months of operation at the Far Detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FIFE-Jobsub: a grid submission system for intensity frontier experiments at Fermilab

The Fermilab Intensity Frontier Experiments use an integrated submission system known as FIFE-jobsub, part of the FIFE (Fabric for Frontier Experiments) initiative, to submit batch jobs to the Open Science Grid. FIFE-jobsub eases the burden on experimenters by integrating data transfer and site selection details in an easy to use and well-documented format. FIFE-jobsub automates tedious details of maintaining grid proxies for the lifetime of the grid job. Data transfer is handled using the Intensity Frontier Data Handling Client (IFDHC) [1] tool suite, which facilitates selecting the appropriate data transfer method from many possibilities while protecting shared resources from overload. Chaining of job dependencies into Directed Acyclic Graphs (Condor DAGS) is well supported and made easier through the use of input flags and parameters.

Box, Dennis↗

The LArIAT experiment at Fermilab

The LArIAT experiment at Fermilab is part of the International Neutrino program recently approved in the US. LArIAT aims to measure the main features of charged particles interactions in argon in the energy range (0.2 - 2.0 GeV) corresponding to the energy spectrum of the same particles when produced in a neutrino-argon interaction (neutrino energies of few GeV) typical of the short- and long-baseline neutrino beams of the Neutrino Program. Data collected from the 1 st Run are being analyzed for both Physics studies and a technical characterization of the scintillation light collection system. Furthermore, two analysis topics are reported: the method developed for charged pion cross section measurement, based on the specific features of the LArTPC, and the development and test of the LArIAT custom-designed cold front-end electronics for SiPM devices to collect LAr scintillation light.

43 PARTICLE ACCELERATORS↗

The calorimeter of the Mu2e experiment at Fermilab

Here, the Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: a straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10 -4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Fermilab Muon g-2 experiment: laser calibration system

The anomalous muon dipole magnetic moment can be measured (and calculated) with great precision thus providing insight on the Standard Model and new physics. Currently an experiment is under construction at Fermilab (U.S.A.) which is expected to measure the anomalous muon dipole magnetic moment with unprecedented precision. One of the improvements with respect to the previous experiments is expected to come from the laser calibration system which has been designed and constructed by the Italian part of the collaboration (INFN). Furthermore, an emphasis of this paper will be on the calibration system that is in the final stages of construction as well as the experiment which is expected to start data taking this year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The laser control of the muon g -2 experiment at Fermilab

Here, we present that the Muon g-2 Experiment at Fermilab is expected to start data taking in 2017. It will measure the muon anomalous magnetic moment, a μ = (g μ -2)/2 to an unprecedented precision: the goal is 0.14 parts per million (ppm). The new experiment will require upgrades of detectors, electronics and data acquisition equipment to handle the much higher data volumes and slightly higher instantaneous rates. In particular, it will require a continuous monitoring and state-of-art calibration of the detectors, whose response may vary on both the millisecond and hour long timescale. The calibration system is composed of six laser sources and a light distribution system will provide short light pulses directly into each crystal (54) of the 24 calorimeters which measure energy and arrival time of the decay positrons. A Laser Control board will manage the interface between the experiment and the laser source, allowing the generation of light pulses according to specific needs including detector calibration, study of detector performance in running conditions, evaluation of DAQ performance. Here we present and discuss the main features of the Laser Control board.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near-infrared scintillation of liquid argon: recent results obtained with the NIR facility at Fermilab

After a short review of previous attempts to observe and measure the near-infrared scintillation in liquid argon, we present new results obtained with NIR, a dedicated cryostat at the Fermilab Proton Assembly Building (PAB). Lastly, the new results give confidence that the near-infrared light can be used as the much needed light signal in large liquid argon time projection chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The laser-based gain monitoring system of the calorimeters in the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04\% precision on the short-term ($\sim 1\,$ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calorimeter. The system is designed to monitor also long-term gain variations, mostly due to temperature effects, with a precision below the per mille level. This article reviews the design, the implementation and the performance of the Muon $g-2$ laser calibration system, showing how the experimental requirements have been met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculations of detuning with amplitude for the McMillan electron lens in the Fermilab Integrable Optics Test Accelerator (IOTA)

The McMillan electron lens will be one of the experimental implementations of nonlinear integrable lattices in the Fermilab Integrable Optics Test Accelerator (IOTA). We describe the physics of the nonlinear McMillan lens and calculate the tune dependence with amplitude from the experimental parameters. Some of the implications for the design of experiments in IOTA are discussed.

43 PARTICLE ACCELERATORS↗

Design of a compact, cryogen-free superconducting solenoid for the electron lens of the Fermilab Integrable Optics Test Accelerator (IOTA)

The proposed electron lens for Fermilab's Integrable Optics Test Accelerator (IOTA) will broaden its capabilities by enabling new research in nonlinear integrable optics, space-charge compensation, proton beam cooling, and more. The electron lens is based on a 5–10 keV, 1–2 A electron beam, shaped using a 0.7 m long, 0.8 T solenoidal magnetic field. A cryogen-free superconducting solenoid has been designed to provide this solenoidal field, taking into consideration the constraints on space, utilities, and infrastructure in the IOTA experimental hall. The solenoid is made of copper stabilized niobium-titanium conductor, conduction-cooled using 4 K closed-cycle cryocoolers. This paper describes the overall design of the solenoid encompassing its mechanical construction, current leads optimization, cryogenic thermal modeling that provides estimates of cooldown time and static/dynamic heat loads, and quench analysis.

43 PARTICLE ACCELERATORS↗

High-accuracy absolute magnetometry with application to the Fermilab Muon g-2 experiment

We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The B-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification as an absolute scalar magnetometer are described. The device was tested at B = 1.45 T but can be modified for a range exceeding 1–3 T. The magnetometer was used to calibrate other NMR magnetometers and measure absolute magnetic field magnitudes to an accuracy of 19 parts per billion as part of a measurement of the muon magnetic moment anomaly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The straw tracking detector for the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗