Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fixture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Characterization of the dynamic densification behavior of cerium dioxide powders as a function of green density

The uniaxial strain dynamic densification behavior of cerium dioxide powders as a function of powder compact green density is investigated in this work. Cerium dioxide powders of two particle morphologies (rod-like and equiaxed) and two green densities (55% and 62.5% TMD) are shock compressed using the gas gun with specifically designed fixtures and their particle and shock wave velocities are measured using VISAR and multiple PDV probes. The obtained data describe the Hugoniot of the shocked cerium dioxide powders. Finally, the method used to produce this high fidelity Hugoniot data for cerium dioxide powders is discussed and preliminary data are shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Inter-digital capacitive sensor for evaluating cable jacket and insulation aging

An inter-digital capacitive (TDC) sensor has previously been used to measure dielectric properties of cable insulation polymer material when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket. The dielectric properties of many cable jacket and insulation polymers are known to change due to thermal and radiation exposure-related damage. These dielectric properties frequently track with other measures of cable aging, such as tensile elongation-at-break and indenter modulus that have been broadly established as cable insulation polymer assessment methods. The external jacket of a cable is likely to have a different permittivity from the underlying insulation, and frequently the jacket material exhibits more severe damage than the insulation material due to environmental exposure. Because the jacket serves primarily to guard the cable during installation, as long as the underlying insulation condition is acceptable, the jacket condition is relatively unimportant in service. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, a set of tools has been developed including (1) a parallel-plate sensor to directly measure the permittivity spectrum of flat sheet material and (2) an TDC and fixture to measure the effect of cable polymer dielectric property change on the sensor response. The TDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. The electrodes are printed on one side of a flexible substrate that can be conformed to the surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad-frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. By finite element modeling (FEM) and experimentation, this study investigates the effect of tine spacing and other design parameters associated with the TDC on the voltage (potential) distribution and electric field depth of penetration. The TDC measurement of an unshielded ethylene-propylene rubber (EPR)-insulated cable is shown to track with the degree of aging and quantities obtained by established methods. For jacketed cable systems, the TDC response is dominated by the jacket but, by analyzing measurements from TDC sensors with different depths-of-field penetration into the cable under test, the influence of the chlorinated polyethylene (CPE) cable jacket material degradation can be separated from an assessment of the cable insulation thereby enabling assessment of the insulation beneath/through the jacket.

Cable NDE, Interdigital Capacitance, Cable test↗

Intrinsic quality factor extraction of multi-port cavity with arbitrary coupling

In this work, we derived S-parameter based expressions for the intrinsic quality factor of an arbitrary coupled multiport microwave cavity and a non-ideal test fixture. Practical accuracy limitations of the obtained expressions specifically for superconducting accelerator cavities were evaluated both analytically and with the simulation software. The resulting formulas can be used to extract the intrinsic quality factor of normal-conducting and superconducting cavities directly from the calibrated S-parameter measurements.

43 PARTICLE ACCELERATORS↗

Simultaneous determination of electrical conductivity and thickness of nonmagnetic metallic foils using two-sided multifrequency eddy current techniques

Here, in this paper, we describe a simple method for performing multifrequency eddy current characterization of free-standing uniform-thickness metallic foils using a forked inductive coil arrangement. The method involves measuring the mutual inductance between two coils when a foil is present between the coils, and when it is not present; the ratio of these mutual inductances is compared with an analytical solution, and foil conductivity, thickness, and sheet resistance are simultaneously estimated using numerical inversion and least-squares fitting. This method was used to characterize 34 non-ferrous metallic samples with thicknesses between 50 and 640 μm and with conductivities between 0.8 × 10 7 and 5.8 × 10 7 S/m. The estimated thicknesses from eddy current characterization agreed well with those measured using confocal optical techniques; the two approaches agreed to within 1 μm for samples that were thinner than 200 μm, and to within 0.5% for samples that had a thickness of 200 μm or greater. The estimated conductivities from eddy current characterization were in close agreement with expected values, given knowledge of the materials used. A particular strength of this approach is that the instrumentation needed is broadly available in research and development laboratories and the associated fixturing is easy to manufacture and assemble. A calibration procedure is described that can be used to reduce errors from geometric uncertainties. This calibration requires a sample that has only a known conductivity or thickness; both do not need to be known. The method described herein is likely extensible to conductivities and thickness well outside the ranges measured as part of this work.

47 OTHER INSTRUMENTATION↗

In-Canal Assay of High Specific Activity 60 Co at the Advanced Test Reactor

Production of high specific activity (HSA) 60 Co has recently resumed at the Advanced Test Reactor (ATR) at the Idaho National Laboratory. The technical steps of performing in-canal assay of HSA 60 Co targets at the ATR are described herein. The HSA targets are assayed on a regular basis, between cycles at the ATR, in order to assess the progress of activation. The targets are also assayed at the conclusion of the irradiation in order to provide activity estimates for the distributor and to be used for safety and shipping evaluations. These target assay activities must take place in the ATR canal to provide sufficient radiological shielding. Furthermore, a specialized assay fixture is used in conjunction with custom 60 Co radiation standards to assess the irradiated target. The specific activity of each irradiated target was determined by first measuring the 60 Co standards to determine a sensitivity factor. Then, each irradiated target was measured, and the integrated measurement was multiplied by the sensitivity factor to determine the total activity of the irradiated target. Finally, a correction factor was determined to adjust the reported activity, accounting for differences in the physical geometries of the standards and targets. These methods were used to accurately assay the gross activity of nine irradiated 60 Co targets, two of which were delivered to the distributor where confirmatory hot-cell assays were performed verifying the accuracy of the in-canal assay method.

07 ISOTOPE AND RADIATION SOURCES↗

High-precision vapor pressure measurement apparatus with facile and inexpensive construction

This study describes an apparatus for high-precision variable temperature measurement of liquid vapor pressure. The apparatus can be used to measure the vapor pressure using only 0.5 ml of the liquid sample. To evaluate the accuracy of the device measurement, water and 2-propanol are utilized as standard liquids, and their vapor pressure is measured with a maximum uncertainty of ~1%. This apparatus can be replicated using inexpensive and commonly used laboratory fittings and fixtures, making it an indispensable tool for synthetic chemists and chemical engineers involved in the iterative synthesis of compounds, targeting different vapor–liquid equilibrium regimes.

Engineering↗

Shielded magnetic small-angle neutron scattering for characterization of radioactive samples

The development of a Pb-shielded fixture for the execution of a small-angle neutron scattering (SANS)-based workflow for interrogation of highly irradiated nuclear materials has been explored. The Pb shielding was specially designed to reduce the detected radioactivity from the specimen during SANS experiments, and the overall configuration is termed shielded magnetic SANS (SM-SANS). Two FeCrAl-based alloys, C35M and 125YF, were examined with the SM-SANS technique using a free-form size distribution locally monodisperse model in both the as-received and irradiated states. Quantitative values derived from the free-form size distribution were compared with atom probe tomography experiments. Microstructural and compositional parameters determined using the two characterization techniques were complements of each other. The results demonstrate that the SM-SANS technique is an effective means of characterizing nanoscale clustering in irradiated material systems and provides new avenues for investigating radioactive material microstructures.

FeCrAl↗

PLC-based Impedance Measurement and Current Injection Response Analysis

Studying and mitigating the vulnerabilities of Programmable Logic Controllers (PLCs) to electromagnetic pulse is important for the reliability of the power system. In this paper, an effective impedance measurement scheme is proposed to estimate the susceptibility of PLCs to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulse Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of PLC.

Qiu, Wei↗

Voltage and Current Response Characteristics of PMU Device by PCI Simulation

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of power system will be affected directly and greatly. As new electronic devices in power system, their immunity to electromagnetic pulse (EMP) events needs to be studied. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. A non-uniform transmission line model is established to eliminate the impact of fixture in the de-embedding process. Then circuit of pulse current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) simulation. Results shows the characteristics of port impedance, voltage and current waveforms. The relation between port impedance and the waveforms is discussed.

Zhang, Liang↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of the power system will be affected directly and greatly. Therefore, it is urgent and necessary to study their immunity to electromagnetic pulse (EMP) events. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then circuit of pulsed current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as a load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) testing simulation. Results show that common-mode impedance is large and differential mode impedance is small. The critical condition will appear in the common mode for voltage and differential mode for current.

Zhang, Liang↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Mechanical Utility Structure for Testing High Field Superconducting Dipole Magnets

The U.S. Magnet Development Program (MDP) collaboration is designing a utility mechanical structure for testing various high-field superconducting dipole coils. The design uses a shell-based structure concept, which allows applying preload in two steps: During a room temperature assembly and during a cool down to a cryogenic temperature. The structure is designed to accommodate various coil designs - including Nb 3 Sn Cosine Theta (CT) and Canted CT magnets as well as hybrid magnets with high temperature superconductor cables. Superconducting coils, enclosed by bolted pads to form an octagonal coil pack, will be inserted into a reusable yoke-shell subassembly and precisely preloaded during the assembly using a bladder-and-key technology. Due to a differential thermal contraction between an external aluminum shell and the magnet core, the coil preload increases during the cool down up to level required for 17-T excitation. Such a reusable structure will serve as a testing fixture supporting goals of the MDP program, decreasing cost and simplifying coil performance testing at different preload levels. We present a finite-element analysis of the structure preloading various coil designs and examine the predicted coil stress at each step of the magnet assembly and excitation.

43 PARTICLE ACCELERATORS↗

Magnetic Field Measurements of First Pre-series Full -Length 4.2 m Quadrupole MQXFA03 Using PCB Rotating Coils for the Hi Hi-Lumi LHC Project

The U.S. Hi-Lumi LHC Accelerator Upgrade Project (AUP) and CERN have joined efforts to develop high field quad-rupoles for the Hi-Lumi LHC upgrade. The US national laborato-ries in the AUP project will deliver 10 magnets and each cryostat has two 4.2 m high gradient quadrupoles in it. These magnets are made of Nb3Sn conductors, with large aperture (150 mm) and in-tegrated gradient of 556.9 T. This paper reports on magnetic measurements performed during the vertical test at Brookhaven National Laboratory (BNL) in 2019-2020. A warm measurement Z-Scan (+/- 15 A) with 42 Z-positions before cool-down was per-formed at BNL. The results were directly compared to field data measured at LBNL during magnet assembly. Measured harmonics and magnetic center offsets (ΔX and ΔY) have provided timely and informative diagnostics on the magnet structure’s shape at both warm and cold temperatures. A new centering fixture was de-signed and added to better center the warm bore tube which con-tains the rotating coil probe. After the quench training to 16.47 kA was achieved, a complete set of cold measurements (Z-Scan at 16.47 kA and I-Scan from 960 A to 16.47 kA and back to 960 A) was made. Periodic axial variation of allowed and nonallowed harmonics was observed which is related to the coil radial and/or mid-plane variations along the magnet axis. Overall, the average harmonics in the straight section are within the required field boundaries.

43 PARTICLE ACCELERATORS↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗

In situ environmental scanning electron microscope observations of colloidal failure mechanisms using the Brazilian disk test

This paper presents data produced using a novel test fixture to study the crack initiation and fracture mechanisms in brittle colloidal systems, in situ in an Environmental Scanning Electron Microscope (ESEM), based on the Brazilian disk test. The test is based on diametral compression loading of a disk of material, which causes a tensile stress in the centre of the disk perpendicular to the loading direction. Key advantages over commercial tensile tests are simplicity of specimen preparation, especially important for fragile and brittle materials, which because of their nature in many cases cannot be microscopically characterised after testing. The test was successful in creating the desired perpendicular tensile stresses and yielded diametral cracks across the latex specimens. It was found that when end crushing was minimal, multiple cracks initiated at several points on the disk and a number of factors appeared to influence the propagation of cracks through the latex, these include: particle packing arrangements, surface defects, and the presence of other cracks. Following the onset of fracture, it was observed that the cracks connected to form a single failure route, here described as the path of least resistance. This, in essence, resulted in the crack taking a route around stronger, more ordered regions of the latex (be they “crystals” or surface defects). The experimental results presented and discussed here represent the first attempt to utilise this loading arrangement in the study of crack propagation in colloidal systems.

42 ENGINEERING↗

Experimental quantification of vent mechanism flow parameters in 18650 format lithium ion batteries

Lithium ion batteries have a well documented tendency to fail energetically under various abuse conditions. These conditions frequently result in decomposition of the electrochemical components within the battery resulting in gas generation and increased internal pressure which can lead to an explosive case rupture. The 18650 format cell incorporates a vent mechanism located within a crimped cap to relieve pressure and mitigate the risk of case rupture. Cell venting, however, introduces additional safety concerns associated with the flow of flammable gases and liquid electrolyte into the environment. Experiments to quantify key parameters are performed to elucidate the external dynamics of battery venting. A first experiment measures the vent burst pressure. Burst vent caps are then tested with a second experimental fixture to measure vent opening area and discharge coefficient during choked-flow venting, which occurs during battery failure. Vent opening area and discharge coefficient are calculated from stagnation temperature, stagnation pressure, and static pressure measurements along with compressible-isentropic flow equations and conservation of mass. Commercially-sourced vent caps are used with repeated tests run to quantify repeatability and variability. Validation experiments confirmed accuracy of opening area and discharge coefficient measurement. Moreover, trials conducted on vent caps from two sources demonstrate the potential for variation between manufacturers.

25 ENERGY STORAGE↗

Multiplanar Stiffness of Commercial Carbon Composite Ankle-Foot Orthoses

The mechanical properties of an ankle-foot orthosis (AFO) can impact how a user's movement is either restricted or augmented by the device. However, standardized methods for assessing stiffness properties of AFOs are lacking, posing a challenge for comparing between devices and across vendors. Therefore, the purpose of this study was to quantify the rotational stiffness of thirteen commercial, nonarticulated, carbon composite ankle-foot orthoses. A custom, instrumented test fixture, for evaluating mechanical properties in rotating exoskeletons (EMPIRE), deflected an AFO through 20 deg of plantar/dorsiflexion motion about a specified, but adjustable, ankle axis. Sagittal, frontal, and transverse plane rotational stiffness were calculated, and reliability was assessed between cycles, sessions, and testers. The EMPIRE demonstrated good-to-excellent reliability between testers, sessions, and cycles (intraclass correlation coefficients all ≥0.95 for sagittal plane stiffness measures). Sagittal plane AFO stiffness ranged from 0.58 N·m/deg to 3.66 N·m/deg. AFOs with a lateral strut demonstrated frontal plane stiffnesses up to 0.71 N·m/deg of eversion while those with a medial strut demonstrated frontal plane stiffnesses up to 0.53 N·m/deg of inversion. Transverse plane stiffnesses were less than 0.30 N·m/deg of internal or external rotation. These results directly compare AFOs of different models and from different manufacturers using consistent methodology and are intended as a resource for clinicians in identifying a device with stiffness properties for individual patients.

Biophysics↗

Production and characterization of thin film group IIIB, IVB and rare earth hydrides by reactive evaporation

A recent short history of reactive evaporation by D. M. Mattox [History Corner—A Short History of Reactive Evaporation, SVC Bulletin (Society of Vacuum Coaters, Spring 2014), p. 50–51] describes various methods for producing oxides, nitrides, carbides, and some compounds, but hydrides were not mentioned. A study was performed in the mid-1970s at the General Electric Company Neutron Devices Department in Largo, FL, by the author to study preparation of thin film hydrides using reactive evaporation and to determine their unique characteristics and properties. Films were produced of scandium (Sc), yttrium (Y), titanium (Ti), zirconium (Zr), and the rare earth praseodymium (Pr), neodymium (Nd), gadolinium (Gd), dysprosium (Dy), and erbium (Er) hydrides by hot crucible filament and electron beam evaporation in atmospheres of deuterium and tritium gases. All-metal vacuum systems were used and those used with tritium were dedicated for this processing. Thin film test samples 1000 nm thick were prepared on 1.27 cm diameter molybdenum disk substrates for each occluder (i.e., an element that can react with hydrogen to form a hydride) material. Loading characteristics as determined by gas-to-metal atomic ratios, oxidation characteristics as determined by argon–sputter Auger analysis, film structure as determined by scanning electron microscope analysis, and film stress properties as determined by a double resonator technique were used to define properties of interest. Results showed hydrogen-to-metal atomic ratios varied from 1.5 to 2.0 with near maximum loading for all but Pr and Nd occluders which correlated with the oxidation levels observed, with all occluder oxidation levels being variable due to vacuum system internal processing conditions and the materials used. Surface oxide levels varied from ∼80 Å to over 1000 Å. For most films studied, results showed that a maximum loading ratio of near 2.0 and a minimum surface oxide level of ∼80 Å could be obtained with a bulk film oxygen level of ∼0.54 oxygen as determined by microprobe analysis when an evaporation rate of ∼0.313 mg/cm{sup 2} min was used in an atmosphere of D{sub 2} or T{sub 2} gas at a system deposition pressure of 1 × 10{sup −3 }Torr (1.33 × 10{sup −1 }Pa) in an evaporation time of ∼2 min. Platelet type (i.e., a film microstructure showing an overlay of flat plates with large grain sizes) film structures were observed for most films with some film mechanical properties determined (i.e., grain size and Vickers μ-hardness), and reduced stress levels were seen with initial normalized differential (tensile) stress levels being (1.0–4.0) × 10{sup 8 }dyne/cm{sup 2} for tritium loaded samples and (1.5 ± 0.5) × 10{sup 9 }dyne/cm{sup 2} for deuterium loaded samples. Also, stress aging characteristics were determined for some hydride films prepared in a radioactive tritium gas atmosphere. Tritium loading, however, had the undesirable characteristic of having to dispose of the internal processing system fixtures, which can be minimized, but the reactive evaporation technique produced desirable thin films.

36 MATERIALS SCIENCE↗