Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Addendum to the Survey Report for the Characterization of the Five Tanks Located Near the Old Salvage Yard at the Y-12 National Security Complex, Oak Ridge, Tennessee

The purpose if this addendum is to provide clarifying information related to two issues delaying disposal of Tank 2, located west of the Old Salvage Yard at the Y-12 National Security Complex. The two issues are as follows: 1. The discovery and documentation of apparent elevated results on the external rusty surface of Tank 2; 2. The proper interpretation and use of scan data. Oak Ridge Associated Universities (ORAU) health physics technicians (HPTs), operating under the Oak Ridge Institute for Science and Education contract, performed 100% scans over accessible interior and exterior surfaces of the five tanks located near the Old Salvage Yard, per the stakeholder-approved project-specific plan. Three types of measurements were collected, including gamma radiation measurements using a Ludlum model 44-10 gamma scintillation detector connected to a Ludlum model 2221 ratemeter/scaler; alpha radiation measurements using a Ludlum model 43-68 gas proportional detector connected to a 2221 ratemeter/scaler; and alpha-plus-beta radiation measurements also using a Ludlum model 43-68 connected to a 2221 ratermeter/scaler. The alpha-plus-beta characterization data is the primary subject of this addendum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment and Mitigation of Radiation, EMP, Debris & Shrapnel Impacts at Megajoule-Class Laser Facilities

The generation of neutron/gamma radiation, electromagnetic pulses (EMP), debris and shrapnel at mega-Joule class laser facilities (NIF and LMJ) impacts experiments conducted at these facilities. The complex 3D numerical codes used to assess these impacts range from an established code that required minor modifications (MCNP - calculates neutron and gamma radiation levels in complex geometries), through a code that required significant modifications to treat new phenomena (EMSolve - calculates EMP from electrons escaping from laser targets), to a new code, ALE-AMR, that is being developed through a joint collaboration between LLNL, CEA, and UC (UCSD, UCLA, and LBL) for debris and shrapnel modelling.

36 MATERIALS SCIENCE↗

Change in the observed half-life of an excited nuclear state under conditions of a resonance environment

A model description of the increase in the observed value of the half-life of isomeric nuclei {sup 119m1}Sn (E = 23.8 keV, T{sub 1/2} {approx} 18 ns) in a resonance environment created by stable nuclei of {sup 119}Sn is proposed. According to the model used, the observed effect is due to gamma radiation from isomeric nuclei {sup 119m1}Sn newly produced upon the resonance capture of gamma rays emitted in {sup 119m1}Sn decay by stable nuclei of {sup 119}Sn. On the basis of T{sub 1/2} values that were measured previously, the radiative shift of the position of an excited nuclear state (nuclear analog of the Lamb shift in an atom), {Delta}{omega}{sub 0}, was estimated at 1.5(2) x 10{sup 11} s{sup -1} for the isomer {sup 119m1}Sn.

74 ATOMIC AND MOLECULAR PHYSICS↗

Afterglow processes responsible for memory effect in nitrogen

The mechanisms responsible for memory effect in nitrogen at 6.6 mbars have been analysed based on experimental data of electrical breakdown time delay as a function of afterglow period. The analysis has shown that positive ions remaining from previous discharge, as well as metastable and highly vibrationally excited molecules, are responsible for memory effect in the early afterglow. These molecules lead to the formation of positive ions in mutual collisions in the afterglow. Positive ions initiate secondary electron emission from the cathode of a nitrogen-filled tube when voltage higher than static breakdown voltage is applied on the electrodes. On the other hand, N({sup 4}S) atoms have a large influence on memory effect in late afterglow. They recombine on the cathode surface forming metastable molecules, which release secondary electrons in collision with the cathode. The higher values of electrical breakdown time delay in the case of the tube with borosilicate glass walls than in the case of the tube with copper walls are a consequence of faster de-excitation of neutral active particles on the glass. Indirect confirmation of this assumption has been obtained when the tubes were irradiated with gamma radiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-E-BRF-01: The ESTRO-AAPM Joint Symposium On Imaging for Proton Treatment Planning and Guidance

In this first inaugural joint ESTRO-AAPM session we will attempt to provide some answers to the problems encountered in the clinical application of particle therapy. Indeed the main advantage is that the physical properties of ion beams offer high ballistic accuracy for tightly conformal irradiation of the tumour volume, with excellent sparing of surrounding healthy tissue and critical organs, This also its Achilles' heel calling for an increasing role of imaging to ensure safe application of the intended dose to the targeted area during the entire course of fractionated therapy. We have three distinguished speakers addressing possible solutions. Katia Parodi (Ludwig Maximilians University, Munich, Germany) To date, Positron Emission Tomography (PET) is the only technique which has been already clinically investigated for in-vivo visualization of the beam range during or shortly after ion beam delivery. The method exploits the transient amount of β{sup 2}-activity induced in nuclear interactions between the primary beam and the irradiated tissue, depending on the ion beam species, the tissue elemental composition and physiological properties (in terms of biological clearance), as well as the time course of irradiation and imaging. This contribution will review initial results, ongoing methodological developments and remaining challenges related to the clinical usage of viable but often suboptimal instrumentation and workflows of PET-based treatment verification. Moreover, it will present and discuss promising new detector developments towards next-generation dedicated PET scanners relying on full-ring or dual-head designs for in-beam quasi real-time imaging. Denis Dauvergne (Institut de Physique Nucleaire de Lyon, Lyon, France) Prompt gamma radiation monitoring of hadron therapy presents the advantage of real time capability to measure the ion range. Both simulations and experiments show that millimetric verification of the range can be achieved at the pencil beam scale for active proton beam delivery in homogenous targets. The development of gamma cameras, that has been studied by several groups worldwide over the last years, now reaches - for some of them - the stage of being applicable in clinical conditions, with real size prototypes and count rate capability matching the therapeutic beam intensities. We will review the different concepts of gamma cameras, the advantages and limitations of this method, and the main challenges that should still be overcome before the widespread of prompt gamma quality assurance for proton and hadrontherapy. Jon Kruse (Mayo Clinic, Rochester, MN, USA) Treatment simulation images for proton therapy are used to determine proton stopping power and range in the patient. This talk will discuss the careful control of CT numbers and conversion of CT number to stopping power required in proton therapy. Imaging for treatment guidance of proton therapy also presents unique challenges which will be addressed. Among them are the enhanced relationship between internal anatomy changes and dosimetry, the need for imaging to support adaptive planning protocols, and high operational efficiency. Learning Objectives: To learn about the possibilities of using activation products to determine the range of particle beams in a patient treatment setting To be informed on an alternative methodology using prompt gamma detectors To understand the impact of the accuracy of the knowledge of the patient information with respect to the delivered treatment.

60 APPLIED LIFE SCIENCES↗

Cosmic-ray induced gamma-ray emission from the starburst galaxy NGC 253

Cosmic rays in galaxies interact with the interstellar medium and give us a direct view of nuclear and particle interactions in the cosmos. For example, cosmic-ray proton interactions with interstellar hydrogen produce gamma rays via PcrPism→π{sup 0}→γγ. For a 'normal' star-forming galaxy like the Milky Way, most cosmic rays escape the Galaxy before such collisions, but in starburst galaxies with dense gas and huge star formation rate, most cosmic rays do suffer these interactions [1,2]. We construct a 'thick-target' model for starburst galaxies, in which cosmic rays are accelerated by supernovae, and escape is neglected. This model gives an upper limit to the gamma-ray emission. Only two free parameters are involved in the model: cosmic-ray proton acceleration energy rate from supernova and the proton injection spectral index. The pionic gamma-radiation is calculated from 10 MeV to 10 TeV for the starburst galaxy NGC 253, and compared to Fermi and HESS data. Our model fits NGC 253 well, suggesting that cosmic rays in this starburst are in the thick target limit, and that this galaxy is a gamma-ray calorimeter.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance Study of an aSi Flat Panel Detector for Fast Neutron Imaging of Nuclear Waste

Radioactive waste must be characterized to check its conformance for intermediate storage and final disposal according to national regulations. For the determination of radio-toxic and chemo-toxic contents of radioactive waste packages non-destructive analytical techniques are preferentially used. Fast neutron imaging is a promising technique to assay large and dense items providing, in complementarity to photon imaging, additional information on the presence of structures in radioactive waste packages. Therefore the feasibility of a compact Neutron Imaging System for Radioactive waste Analysis (NISRA) using 14 MeV neutrons is studied in a cooperation framework of Forschungszentrum Juelich GmbH, RWTH Aachen University and Siemens AG. However due to the low neutron emission of neutron generators in comparison to research reactors the challenging task resides in the development of an imaging detector with a high efficiency, a low sensitivity to gamma radiation and a resolution sufficient for the purpose. The setup is composed of a commercial D-T neutron generator (Genie16GT, Sodern) with a surrounding shielding made of polyethylene, which acts as a collimator and an amorphous silicon flat panel detector (aSi, 40 x 40 cm{sup 2}, XRD-1642, Perkin Elmer). Neutron detection is achieved using a general propose plastic scintillator (EJ-260, Eljen Technology) linked to the detector. The thermal noise of the photodiodes is reduced by employing an entrance window made of aluminium. Optimal gain and integration time for data acquisition are set by measuring the response of the detector to the radiation of a 500 MBq {sup 241}Am-source. Detector performance was studied by recording neutron radiography images of materials with various, but well known, chemical compositions, densities and dimensions (Al, C, Fe, Pb, W, concrete, polyethylene, 5 x 8 x 10 cm{sup 3}). To simulate gamma-ray emitting waste radiographs in presence of a gamma-ray sources ({sup 60}Co, {sup 137}Cs, {sup 241}Am) were performed. A homemade algorithm was developed to determine a value which is related to the neutron absorption of the sample with the analysis of the raw detector data. The detector was placed 42 cm away from the neutron source. Distance between detector and the samples was 0.5 cm. At the sample position the fast neutron flux was estimated to 9x10{sup 3} n cm{sup -2} s{sup -1} for a neutron emission of 10{sup 8} n s{sup -1}. The acquisition time was 15 minutes. First neutron radiographs were successfully recorded despite the low detector efficiency and low neutron emission. Analysis of the data shows a correlation between the measured signal and determined neutron absorption. Thus discrimination between different materials of same thicknesses may be achieved. The measurements and results will be presented and discussed in details.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alteration of cytokine profiles in mice exposed to chronic low-dose ionizing radiation

While a high-dose of ionizing radiation is generally harmful and causes damage to living organisms, a low-dose of radiation has been shown to be beneficial in a variety of animal models. To understand the basis for the effect of low-dose radiation in vivo, we examined the cellular and immunological changes evoked in mice exposed to low-dose radiation at very low (0.7 mGy/h) and low (3.95 mGy/h) dose rate for the total dose of 0.2 and 2 Gy, respectively. Mice exposed to low-dose radiation, either at very low- or low-dose rate, demonstrated normal range of body weight and complete blood counts. Likewise, the number and percentage of peripheral lymphocyte populations, CD4{sup +} T, CD8{sup +} T, B, or NK cells, stayed unchanged following irradiation. Nonetheless, the sera from these mice exhibited elevated levels of IL-3, IL-4, leptin, MCP-1, MCP-5, MIP-1{alpha}, thrombopoietin, and VEGF along with slight reduction of IL-12p70, IL-13, IL-17, and IFN-{gamma}. This pattern of cytokine release suggests the stimulation of innate immunity facilitating myeloid differentiation and activation while suppressing pro-inflammatory responses and promoting differentiation of naive T cells into T-helper 2, not T-helper 1, types. Collectively, our data highlight the subtle changes of cytokine milieu by chronic low-dose {gamma}-radiation, which may be associated with the functional benefits observed in various experimental models.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Prompt-gamma detection towards absorbed energy monitoring during hadrontherapy

Hadrontherapy is an emerging technique which exploits the fact that a large quantity of the energy of the incident particles is deposited at the end of their flight path. This allows a conformation of the applied dose to the tumor volume and a simultaneous sparing of surrounding healthy tissue. A real-time control of the ion range during the treatment is possible via the detection of prompt secondary radiation (gamma rays or charged particles). Besides a monitoring of the ion range, the knowledge of the total energy absorbed inside the patient is also of importance for an improvement of the treatment quality. It has been shown that the ambient dose in a treatment room is correlated to the monitoring units, i.e. the number of protons of the beam delivery system. The present study consists in applying time-of-flight (TOF) information to identify prompt gamma-rays generated by interactions inside the patient which provides a direct information on the energy imparted. Results from test measurements will be given, which show that events generated in the nozzle and the target phantom can be discriminated. Furthermore, a standalone detection system is being developed which will be read out by a standard PC. The status of the developments for the corresponding electronics will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermoluminescence and dielectric response of gamma irradiated muscovite mica

The effect of gamma radiation dose on the thermoluminescence (TL) and dielectric properties of muscovite mica was studied. TL glow curves exhibited a single peak around 141 {sup 0}C and its activation energy was estimated to be about 0.89 eV. Different dielectric parameters like dielectric constant, dielectric loss and ac conductivity have been calculated in both pristine and gamma irradiated samples. These dielectric parameters have been studied as a function of irradiation dose.

36 MATERIALS SCIENCE↗

Genotoxic effects of high-energy iron particles in human lymphoblasts differing in radiation sensitivity

The effects of (56)Fe particles and (137)Cs gamma radiation were compared in TK6 and WTK1 human lymphoblasts, two related cell lines which differ in TP53 status and in the ability to rejoin DNA double-strand breaks. Both cell lines were more sensitive to the cytotoxic and clastogenic effects of (56)Fe particles than to those of gamma rays. However, the mutagenicity of (56)Fe particles and gamma rays at the TK locus was the same per unit dose and was higher for gamma rays than for (56)Fe particles at isotoxic doses. The respective RBEs for TK6 and WTK1 cells were 1.5 and 1.9 for cytotoxicity and 2.5 and 1.9 for clastogenicity, but only 1 for mutagenicity. The results indicate that complex lesions induced by (56)Fe particles are repaired less efficiently than gamma-ray-induced lesions, leading to fewer colony-forming cells, a slightly higher proportion of aberrant cells at the first division, and a lower frequency of viable mutants at isotoxic doses. WTK1 cells (mutant TP53) were more resistant to the cytotoxic effects of both gamma rays and (56)Fe particles, but showed greater cytogenetic and mutagenic damage than TK6 cells (TP53(+)). A deficiency in the number of damaged TK6 cells (a) reaching the first mitosis after exposure and (b) forming viable mutants can explain these results.

Non-NASA Center↗

Materials Modeling for High-Performance Radiation Detectors

Limitations in the performance of room-temperature gamma radiation detectors are intimately related to the properties of the materials used to fabricate them. In particular, atomic-scale defects in the materials that can depend on crystal growth or device processing conditions often ultimately determine the performance of a given detector. Understanding the origins and consequences of these various defects is essential to optimizing the materials and achieving maximum device performance (e.g., energy resolution and sensitivity). This project aims to enable rational materials design for select high-payoff challenges in radiation detection materials by using state-of-the-art modeling techniques bridging multiple resolutions. Three specific high-impact challenges are addressed: (i) design and optimization of electrical contact stacks for thallium bromide (TlBr) detectors to stabilize temporal response at room-temperature; (ii) design of host glass for large-volume, low-cost, high-performance glass scintillators; and (iii) determination of the electrical impacts of dislocation networks in cadmium zinc telluride (CZT) that limit its performance and usable single-crystal volume.

36 MATERIALS SCIENCE↗

Observations of diffuse galactic gamma rays

The observations of galactic diffuse gamma radiation are reviewed. The connections of the gamma ray observations with galactic structure and cosmic rays are discussed. The high latitude galactic component and the low latitude emission from the galactic plane are examined. The observations in other regions of the gamma ray spectrum are discussed.

Simpson, G. A.↗

Prompt Gamma Neutron Activation Analysis of Niobium for Characterization of Light Interstitials

High purity niobium metal is used in the construction of superconducting radio frequency (SRF) cavities in superconducting particle accelerators. The Spallation Neutron Source at Oak Ridge National Laboratory is an example of an SRF linear accelerator (LINAC) that requires this high purity niobium material. For the SRF cavities to function well, it is necessary that the cavity wall have a high thermal conductivity so that the radio frequency (RF) power can be dissipated into the liquid helium coolant. For a high thermal conductivity of the niobium metal to be achieved, it is required to have extremely low levels of impurities. The current industry standard for determining the quality of the high purity niobium material is the residual resistivity ratio (RRR) technique. In this technique, the temperature dependency of a niobium metal sample is determined at temperatures near that of liquid helium in order to establish where the superconducting jump occurs. With this method, it is possible to find the general level of impurity of the metal sample, but not the specific elements that are contributing to the impurity. The impurities that are of particular interest to manufacturers of niobium for SRF use are tantalum and light interstitials, such as hydrogen, carbon, nitrogen, and oxygen. In this research, we focus on determining the analytical sensitivity of the detector system and characterizing the light interstitial content in high purity niobium metal through the use of Prompt Gamma Neutron Activation Analysis (PGNAA). PGNAA is an analytical technique that can be utilized to determine the concentration of elemental components in a wide variety of materials with high precision and reproducibility. In this process, neutrons bombard a sample material, causing the emission of gamma rays from the sample. Each element emits a unique spectrum of gamma radiation, which allows for identification of the elements present in the sample. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Durability of Containers for the Disposal of Radioactive Waste - Swiss and Belgian R and D Studies - 19392

In this paper, we present a summary of the results from research and development (R and D) studies associated with the durability of steel-based disposal canisters for high-level waste (HLW) and spent nuclear fuel (SNF), focusing on experimental studies carried out in support of the Swiss and Belgian disposal programmes. We present the results of laboratory studies carried out for periods of the order of ten to twenty years, and compare them with more recent observations from in situ experiments carried out at the Mont Terri and Grimsel underground laboratories. For the Belgian programme, which is currently envisaging relatively high gamma dose rates outside the steel overpack, we also show the results of studies focusing on gamma radiation at dose rates compatible with those expected in the disposal system. These studies show how, in bentonite systems, corrosion rates decrease to values lower than 1 μm year{sup -1} after an initial period. In the case of cement-based systems, corrosion rates lower than 0.1 μm year{sup -1} are typically observed, with modest effects of gamma irradiation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GammaPod-A new device dedicated for stereotactic radiotherapy of breast cancer

Purpose: This paper introduces a new external beam radiotherapy device named GammaPod that is dedicated for stereotactic radiotherapy of breast cancer. Methods: The design goal of the GammaPod as a dedicated system for treating breast cancer is the ability to deliver ablative doses with sharp gradients under stereotactic image guidance. Stereotactic localization of the breast is achieved by a vacuum-assisted breast immobilization cup with built-in stereotactic frame. Highly focused radiation is achieved at the isocenter due to the cross-firing from 36 radiation arcs generated by rotating 36 individual Cobalt-60 beams. The dedicated treatment planning system optimizes an optimal path of the focal spot using an optimization algorithm borrowed from computational geometry such that the target can be covered by 90%-95% of the prescription dose and the doses to surrounding tissues are minimized. The treatment plan is intended to be delivered with continuous motion of the treatment couch. In this paper the authors described in detail the gamma radiation unit, stereotactic localization of the breast, and the treatment planning system of the GammaPod system. Results: A prototype GammaPod system was installed at University of Maryland Medical Center and has gone through a thorough functional, geometric, and dosimetric testing. The mechanical and functional performances of the system all meet the functional specifications. Conclusions: An image-guided breast stereotactic radiotherapy device, named GammaPod, has been developed to deliver highly focused and localized doses to a target in the breast under stereotactic image guidance. It is envisioned that the GammaPod technology has the potential to significantly shorten radiation treatments and even eliminate surgery by ablating the tumor and sterilizing the tumor bed simultaneously.

60 APPLIED LIFE SCIENCES↗