Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Specifications of Legacy U(Pu)Zr Metallography Data

The DOE Nuclear Energy Advanced Reactor Technologies (ART) Program has supported the creation of several databases with information describing the safety performance of fast reactors, components, and fuels. This growing collection of legacy experimental data, operating data, and analysis is available online to registered users. Metallography data is one of the most important types of PIE data being collected, organized and stored in several ART Fast Reactor Databases (https://frdb.ne.anl.gov), including the Fuels Irradiation & Physics Database (FIPD), Out-of-Pile Transient Database (OPTD), and TREAT (the Transient Reactor Test Facility) Experimental Relational Database (TREXR). These databases contain three main sets of metallography data. The first set is the metallography data from Experimental Breeder Reactor-II (EBR-II) and Fast Flux Test Facility (FFTF) irradiated fuel pins measured in the Hot Fuel Examination Facility (HFEF); the second set is the metallography data from EBR-II irradiated fuel pins measured in the Alpha-Gamma Hot Cell Facility (AGHCF); the third set is the metallography data from transient tested fuel pins (the transients tests include the out-of-pile tests and TREAT tests) measured in AGHCF. Since both the second and third sets of data were measured in AGHCF, they are governed by the same specification. The metallography data in the databases are digital images scanned from either positive or negative photos. The quality of the images, including their resolution and contrast, relies on the preserved quality of the pictures and the scanning conditions. To analyze the microstructure of a fuel pin, a series of preparatory steps must be undertaken. These include sectioning, epoxy mounting, mechanical grinding and polishing, and often etching. The resulting samples were then transferred to a secondary hot cell, or glovebox (depending the strength of radiation field) for microscopy examination. The specifications provided herein focus on the metallography examinations. The sample grinding, polishing and etching processes are also discussed. The procedures involving sectioning and epoxy mounting are out of the scope of the current specification; details can be found in the corresponding operation manuals. If more data are collected and added to the ART Fast Reactor Databases, this specification will be updated to accommodate the additional data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

GIOVE, a shallow laboratory Ge-spectrometer with 100 μBq/kg sensitivity

A new germanium gamma spectrometer called GIOVE (Germanium spectrometer with Inner and Outer Veto) has been set up at the underground/shallow laboratory (15 m w.e.) of MPI-K. Its double plastic scintillator veto system and neutron moderation interlayer lower the background by more than one order of magnitude compared to the other existing spectrometer at this facility. The integral (40-2700 keV) background rate of about 290 counts (day kg){sup −1} is just a factor 4 to 8 above that of the GeMPI spectrometers operated at LNGS (3800 m w.e.) and thus proves that even under shallow overburden sub mBq/kg sensitivities are achievable. Extended material screening and neutron attenuation studies preceded the final design of the spectrometer. The technical realization of the spectrometer is described in detail with special emphasis on the inner veto system. For its optimisation a simulation model was developed for light collection on small low activity PMT’s under various geometrical conditions. Radon suppression is accomplished by employing a gas tight sample container and a nitrogen flushed glove-box system with an airlock. The active volume of the crystal was modelled by absorption scanning measurements and Monte Carlo simulations. The complete shield is implemented in a Geant4 based simulation framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-Dimensional Dose Addition of External Beam Radiotherapy and Brachytherapy for Oropharyngeal Patients Using Nonrigid Registration

Purpose: To develop and evaluate a method for adding dose distributions of combined external beam radiotherapy (EBRT) and brachytherapy (BT) for oropharyngeal patients. Methods and Materials: Two computed tomography (CT) scans were used for 5 patients: the EBRT CT, used for EBRT planning, and the BT CT, acquired after catheter implantation. For each scan, the salivary glands and the chewing and swallowing muscles were contoured, and a dose distribution was calculated. A nonrigid transformation was obtained by registering the organs' surfaces. Then the BT dose distribution was mapped onto the EBRT dose distribution by applying the transformation obtained. To account for differences in fractionation, the physical doses were converted to equivalent dose in 2 Gy (EQD{sub 2}), and the total dose was found by adding dose voxel by voxel. The robustness of the dose addition was investigated by varying delineations and input parameters of the registration method and by varying the {alpha}/{beta} parameter for EQD{sub 2}. The effect of the perturbations was quantified using dose-volume histograms (DVH) and gamma analyses (distance-to-agreement/dose-difference = 1 mm/1 Gy). Results: The variations in input parameters and delineations caused only small perturbations in the DVH of the added dose distributions. For most organs the gamma index was low, and it was moderately elevated for organs lying in areas with a steep gradient (median gamma index {<=}2.3 for constrictor muscles, {<=}0.7 for all other organs). Conclusions: The presented method allows adding dose distributions of combined EBRT and BT for oropharyngeal patients. In general, the method is reliable and robust with respect to uncertainties in organ delineation, perturbations in input parameters of the method, and {alpha}/{beta} values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differential dose volume histograms of Gamma Knife in the presence of inhomogeneities using MRI-polymer gel dosimetry and MC simulation

Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose volume histograms (DVHs) for single-shot irradiations of the Gamma Knife (GK) unit were used to investigate the effects of the presence of inhomogeneities on 3D dose distribution. The head phantom was a custom-built 16 cm diameter Plexiglas sphere. Inside the phantom, there is a cubic cutout for inserting the gel vials and another cutout for inserting the inhomogeneities. Following irradiation with the GK unit, the polymer gel phantoms were scanned with a 1.5 T MRI scanner. Comparing the results of measurement in homogeneous and heterogeneous phantoms revealed that inserting inhomogeneities inside the homogeneous phantom did not cause considerable disturbances on dose distribution in irradiation with 8 mm collimator within low isodose levels (<50%), which is essential for the dose sparing of sensitive structures. The results of simulation for homogeneous and inhomogeneous phantoms in irradiation with 18 mm collimator of the GK unit showed 23.24% difference in DVH within 90%-100% relative isodose level and also revealed that a significant part of the target (28.56%) received relative doses higher than the maximum dose, which exceeds the acceptance criterion (5%). Based on these results it is concluded that the presence of inhomogeneities inside the phantom can cause considerable errors in dose calculation within high isodose levels with respect to LGP prediction which assumes that the target is a homogeneous material. Moreover, it is demonstrated that the applied MC code is an accurate and stand-alone tool for 3D evaluation of dose distribution in irradiation with the GK unit, which can provide important, 3D plan evaluation criteria used in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray tomographic in-service inspection of girth welds - The European project TomoWELD

The new standard 'ISO 17636-2:2013: Non-destructive testing of welds - Radiographic testing - Part 2: X- and gamma-ray techniques with digital detectors', defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined.

36 MATERIALS SCIENCE↗

Adsorption properties of carbonized polyacrylonitrile deposited on {gamma}-alumina and silica gel by precipitation polymerization

The precipitation polymerization method was used for the deposition of various contents of polyacrylonitrile on two oxide-type supports ({gamma}-alumina and silica gel). The synthesized materials were characterized by thermal analysis performed in inert and oxidizing atmospheres. The mechanism of polyacrylonitrile decomposition was proposed. In order to gain effective adsorbents of volatile organic compounds the polyacrylonitrile/support composites were carbonized at elevated temperatures. The texture and morphology of the calcined materials were examined by low-temperature sorption of N{sub 2} and scanning electron microscopy, respectively. An influence of thermal treatment conditions and carbonaceous species loading on adsorption capacity of methyl-ethyl ketone vapour was also determined. Attenuated total reflection Fourier transform infrared spectroscopy measurements revealed that the ladder-type polyacrylonitrile species formed above 250 {sup o}C and stable up to about 350-400 {sup o}C are the most effective sites for methyl-ethyl ketone sorption. The carbonaceous species dispersion was found to be an additional factor influencing the adsorption capacity of the carbonized polyacrylonitrile/support composites.

36 MATERIALS SCIENCE↗

Targeting accuracy of single-isocenter intensity-modulated radiosurgery for multiple lesions

To investigate the targeting accuracy of intensity-modulated SRS (IMRS) plans designed to simultaneously treat multiple brain metastases with a single isocenter. A home-made acrylic phantom able to support a film (EBT3) in its coronal plane was used. The phantom was CT scanned and three coplanar small targets (a central and two peripheral) were outlined in the Eclipse system. Peripheral targets were 6 cm apart from the central one. A reference IMRS plan was designed to simultaneously treat the three targets, but only a single isocenter located at the center of the central target was used. After positioning the phantom on the linac using the room lasers, a CBCT scan was acquired and the reference plan were mapped on it, by placing the planned isocenter at the intersection of the landmarks used in the film showing the linac isocenter. The mapped plan was then recalculated and delivered. The film dose distribution was derived using a cloud computing application ( (www.radiochromic.com)) that uses a triple-channel dosimetry algorithm. Comparison of dose distributions using the gamma index (5%/1 mm) were performed over a 5 × 5 cm{sup 2} region centered over each target. 2D shifts required to get the best gamma passing rates on the peripheral target regions were compared with the reported ones for the central target. The experiment was repeated ten times in different sessions. Average 2D shifts required to achieve optimal gamma passing rates (99%, 97%, 99%) were 0.7 mm (SD: 0.3 mm), 0.8 mm (SD: 0.4 mm) and 0.8 mm (SD: 0.3 mm), for the central and the two peripheral targets, respectively. No statistical differences (p > 0.05) were found for targeting accuracy between the central and the two peripheral targets. The study revealed a targeting accuracy within 1 mm for off-isocenter targets within 6 cm of the linac isocenter, when a single-isocenter IMRS plan is designed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiparameter linear least-squares fitting to Poisson data one count at a time

A standard problem in gamma-ray astronomy data analysis is the decomposition of a set of observed counts, described by Poisson statistics, according to a given multicomponent linear model, with underlying physical count rates or fluxes which are to be estimated from the data. Despite its conceptual simplicity, the linear least-squares (LLSQ) method for solving this problem has generally been limited to situations in which the number n(sub i) of counts in each bin i is not too small, conventionally more than 5-30. It seems to be widely believed that the failure of the LLSQ method for small counts is due to the failure of the Poisson distribution to be even approximately normal for small numbers. The cause is more accurately the strong anticorrelation between the data and the wieghts w(sub i) in the weighted LLSQ method when square root of n(sub i) instead of square root of bar-n(sub i) is used to approximate the uncertainties, sigma(sub i), in the data, where bar-n(sub i) = E(n(sub i)), the expected value of N(sub i). We show in an appendix that, avoiding this approximation, the correct equations for the Poisson LLSQ (PLLSQ) problems are actually identical to those for the maximum likelihood estimate using the exact Poisson distribution. We apply the method to solve a problem in high-resolution gamma-ray spectroscopy for the JPL High-Resolution Gamma-Ray Spectrometer flown on HEAO 3. Systematic error in subtracting the strong, highly variable background encountered in the low-energy gamma-ray region can be significantly reduced by closely pairing source and background data in short segments. Significant results can be built up by weighted averaging of the net fluxes obtained from the subtraction of many individual source/background pairs. Extension of the approach to complex situations, with multiple cosmic sources and realistic background parameterizations, requires a means of efficiently fitting to data from single scans in the narrow (approximately = 1.2 keV, HEAO 3) energy channels of a Ge spectrometer, where the expected number of counts obtained per scan may be very low. Such an analysis system is discussed and compared to the method previously used.

Wheaton, Wm. A.↗

Automated planning of breast radiotherapy using cone beam CT imaging

Purpose: Develop and clinically validate a methodology for using cone beam computed tomography (CBCT) imaging in an automated treatment planning framework for breast IMRT. Methods: A technique for intensity correction of CBCT images was developed and evaluated. The technique is based on histogram matching of CBCT image sets, using information from “similar” planning CT image sets from a database of paired CBCT and CT image sets (n = 38). Automated treatment plans were generated for a testing subset (n = 15) on the planning CT and the corrected CBCT. The plans generated on the corrected CBCT were compared to the CT-based plans in terms of beam parameters, dosimetric indices, and dose distributions. Results: The corrected CBCT images showed considerable similarity to their corresponding planning CTs (average mutual information 1.0±0.1, average sum of absolute differences 185 ± 38). The automated CBCT-based plans were clinically acceptable, as well as equivalent to the CT-based plans with average gantry angle difference of 0.99°±1.1°, target volume overlap index (Dice) of 0.89±0.04 although with slightly higher maximum target doses (4482±90 vs 4560±84, P < 0.05). Gamma index analysis (3%, 3 mm) showed that the CBCT-based plans had the same dose distribution as plans calculated with the same beams on the registered planning CTs (average gamma index 0.12±0.04, gamma <1 in 99.4%±0.3%). Conclusions: The proposed method demonstrates the potential for a clinically feasible and efficient online adaptive breast IMRT planning method based on CBCT imaging, integrating automation.

60 APPLIED LIFE SCIENCES↗

Assessment of a mechanistic model in U-Pu-Zr metallic alloy fuel fission-gas behavior simulations

A mechanistic kinetic rate theory model originally developed for the prediction of fission gas behavior in oxide nuclear fuels under steady-state and transient conditions has been assessed to look at its applicability to model fission gas behavior in U-Pu-Zr metallic alloy fuel. In order to capture and validate the underlying physics for irradiated U-Pu-Zr fuels, the mechanistic model was applied to the simulation of fission gas release, fission gas and fission product induced swelling, and the evolution of the gas bubble size distribution in three different fuel zones: the outer {alpha}-U, the intermediate, and the inner {gamma}-U zones. Due to its special microstructural features, the {alpha}-U zone in U-Pu-Zr fuels is believed to contribute the largest fraction of fission gas release among the different fuel zones. It is shown that with the use of small effective grain sizes, the mechanistic model can predict fission gas release that is consistent with (though slightly lower than) experimentally measured data. These simulation results are comparable to the experimentally measured fission gas release since the mechanism of fission gas transport through the densely distributed laminar porosity in the {alpha}-U zone is analogous to the mechanism of fission gas transport through the interconnected gas bubble porosity utilized in the mechanistic model. Detailed gas bubble size distributions predicted with the mechanistic model in both the intermediate zone and the high temperature {gamma}-U zone of U-Pu-Zr fuel are also compared to experimental measurements from available SEM micrographs. These comparisons show good agreements between the simulation results and experimental measurements, and therefore provide crucial guidelines for the selection of key physical parameters required for modeling these two zones. In addition, the results of parametric studies for several key parameters are presented for both the intermediate zone and the {gamma}-U zone simulations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A method of dose reconstruction for moving targets compatible with dynamic treatments

Purpose: To develop a method that allows a commercial treatment planning system (TPS) to perform accurate dose reconstruction for rigidly moving targets and to validate the method in phantom measurements for a range of treatments including intensity modulated radiation therapy (IMRT), volumetric arc therapy (VMAT), and dynamic multileaf collimator (DMLC) tracking. Methods: An in-house computer program was developed to manipulate Dicom treatment plans exported from a TPS (Eclipse, Varian Medical Systems) such that target motion during treatment delivery was incorporated into the plans. For each treatment, a motion including plan was generated by dividing the intratreatment target motion into 1 mm position bins and construct sub-beams that represented the parts of the treatment that were delivered, while the target was located within each position bin. For each sub-beam, the target shift was modeled by a corresponding isocenter shift. The motion incorporating Dicom plans were reimported into the TPS, where dose calculation resulted in motion including target dose distributions. For experimental validation of the dose reconstruction a thorax phantom with a moveable lung equivalent rod with a tumor insert of solid water was first CT scanned. The tumor insert was delineated as a gross tumor volume (GTV), and a planning target volume (PTV) was formed by adding margins. A conformal plan, two IMRT plans (step-and-shoot and sliding windows), and a VMAT plan were generated giving minimum target doses of 95% (GTV) and 67% (PTV) of the prescription dose (3 Gy). Two conformal fields with MLC leaves perpendicular and parallel to the tumor motion, respectively, were generated for DMLC tracking. All treatment plans were delivered to the thorax phantom without tumor motion and with a sinusoidal tumor motion. The two conformal fields were delivered with and without portal image guided DMLC tracking based on an embedded gold marker. The target dose distribution was measured with a radiochromic film in the moving rod and compared with the reconstructed doses using gamma tests. Results: Considerable interplay effects between machine motion and target motion were observed for the treatments without tracking. For nontracking experiments, the mean 2 mm/2% gamma pass rate over all investigated scenarios was 99.6% between calculated and measured doses. For tracking experiments, the mean gamma pass rate was 99.4%. Conclusions: A method for accurate dose reconstruction for moving targets with dynamic treatments was developed and experimentally validated in a variety of delivery scenarios. The method is suitable for integration into TPSs, e.g., for reconstruction of the dose delivered to moving tumors or calculation of target doses delivered with DMLC tracking.

60 APPLIED LIFE SCIENCES↗

Effects of deformation on microstructure and mechanical properties of a Cu-Al-Ni shape memory alloy

In Cu-11.92 wt.%Al-3.78 wt.%Ni shape memory alloy, the influence of deformation and thermal treatments on the microstructure and mechanical properties under the compression test were studied by means of scanning electron microscopy (SEM), transmission electron microscopy (TEM), and differential scanning calorimetry (DSC). Experiments show that the mechanical properties of the alloy can be enhanced by convenient heat treatments. The alloy exhibits good mechanical properties with high ultimate compression strength and ductility after annealing at high temperature. However, it exhibits brittle fracture and dramatic strain hardening, with linear stress-strain behavior after annealing at low temperature. The changes in the mechanical properties have been linked to the evolution of the degree of order, occurrence of precipitation, and variation of the grain size. From microstructural observations, it is seen that the {beta}{sub 1}' (18R) and {gamma}{sub 1}' (2H) martensite phases coexist at different fractions in the undeformed and deformed states. Deformation induces the changes between the {beta}{sub 1}' and {gamma}{sub 1}' martensites and deformation-induced martensites form at preferred orientations as mechanical twins. The {beta}{sub 1}' martensite variants are twin-related with respect to the (1-bar 2-bar 8){sub 18R} mirror plane and a new orientation relationship for these twin variants is derived as (1-bar 2-bar 8){sub A}-parallel (1-bar 2-bar 8){sub C}: [4-bar 61] {sub A}-parallel [4-bar 61]{sub C}. Additionally, an increase in the amount of deformation causes martensite reorientation, de-twinning, and dislocation generation; also, the martensite plates are seen to have rearranged in the same orientation to be parallel with each other.

36 MATERIALS SCIENCE↗

SU-F-T-161: The Effect of Pencil Beam Scanning Gantry Angle Dependent Spot Size Variations On Plan Quality

Purpose: To investigate the effect of spot size variation as function of gantry angle on the quality of treatment plans for pencil beam scanning proton plans. Method: Three homogeneous 26×26×7cm dose volumes with different ranges and SOBPs were delivered on the matrixxPT 2D array at gantry angles of 0 and 270 degrees. The spot size sigma varies by 1.8, 7.8, and 1.4%, for nominal energies of 215, 183, and 103 MeV (Range 29, 22, and 8cm, respectively). The resulting dose planes are compared and evaluated with the gamma index for 2%/2mm and 1%/1mm criteria. Results: Patient specific QA is performed at a gantry angle of 0 degrees. However, beam sigmas vary as function of gantry angle because of the beam optics for each gantry. This will cause differences between the delivered and planned treatment plans. Delivered plans were compared and a gamma pass rate of 96.5% for criteria of 2%/2mm and 91.4% for 1%/1mm were seen for plans with a nominal energy of 183 MeV. For plans with a nominal energy of 103 MeV, gamma pass rates of 97.3% for 2%/2mm and 91.5% for 1%/1mm were seen. For plans with a nominal energy of 215 MeV the pass rate was 99.8% for 1%/1mm between the two gantry angles. Conclusion: Differences in beam sigma of up to 7.8% do not cause significant differences in the dose distribution of different spot size gammas.

60 APPLIED LIFE SCIENCES↗

Multipole error data analysis for RHIC low-energy operations

In FY10, RHIC operated with gold beams at three different energies below its regular injection energy, namely at $\sqrt{s}$ = 5 GeV, 7.7 GeV, and 11.5 GeV. While beam lifetimes of about 10 minutes were achieved at 11.5 GeV and 7.7 GeV, leading to stable collider operation, beam lifetimes during tests at $\sqrt{s}$ = 5 GeV were only of the order of several seconds. Though space charge effects are a major concern in low energy operations due to the $1/\gamma^2$ scaling of the space charge force, these can effectively be ruled out as the main cause of this abysmal performance because of the tiny bunch intensities of approximately $10^8$ Au/bunch, compared to $10^9$ Au/bunch at the two higher energies. During these 5 GeV tests, large betatron tune spreads were observed, but the extremely short beam lifetime prevented chromaticity measurements. Instead, chromaticities were scanned over a range of 40 units, but to no effect. It was therefore suspected at that time that the large tune spread was caused by higher-order multipole errors in the RHIC magnets.

43 PARTICLE ACCELERATORS↗

Rare Earth Elements (REE) and Critical Minerals (CM) in Middle Pennsylvanian-Age Coals and Associated Sediments in the Central Appalachian Basin, Eastern U.S.A.

The Central Appalachian Basin (CAB) of Kentucky, Tennessee, West Virginia and Virginia has a long history of coal mining and oil and gas extraction that has empowered the regional and national economies, the development of infrastructure, and a highly trained energy resources work force. As our societal demands for advanced technologies have rapidly increased in recent years, coal-related materials are viewed as an important new unconventional domestic source of critical minerals (CM) that are required for telecommunications, aerospace and transportation industries, electronics, the transition to low-carbon emissions energy production, and many consumer products. Coal-related materials encompass coal, associated sediments, coal mining waste materials, produced waters, and ash residues from coal-fired power plants. An important objective of the Evolve Central Appalachia Project (Evolve CAPP), sponsored by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) is to assess the quantity and distribution of CM resources in the CAB region. The rare earth elements (REE) are considered highest priority, although other important CM such as niobium, gallium, and zirconium are known to occur in the Middle Pennsylvanian-age coals and sediments. Working with coal industry partners who provided access to drill cores, coal-related sediments and waste materials, over 600 samples have been collected for laboratory analysis, and over 730 materials have been scanned using portable x-ray fluorescence (pXRF) equipment. The application of pXRF provides the means for real-time semiquantitative analysis of CM content at very close spacings (typically 2-3 inch intervals) along drill core and in-situ channel samples that span the roof, coal seam, and floor rock. The comparison of pXRF geochemical data with laboratory results, geologic data, and downhole spectral gamma logs can provide high resolution input to lithologic and depositional models for future CM resource evaluations. The preliminary findings show that pXRF is capable of accurately measuring low concentrations of many of the CM with a high level of confidence (Ba, Cr, Ga, K, Nb, Rb, Sr, Th, Y), whereas for others (La, Ce, Co, Mn, Nd, Ni, Sc, Ti, V) the detection limits are very high or spectral interferences increase the uncertainty. Notably, the mean abundances of Y (34 ppm), La (86 ppm), Ga (40 ppm), and V (146 ppm) in coal underclays in the CAB region are up to 7X enriched compared with the overlying coal. These values also exceed the reported concentrations in published reference materials for upper continental crustal rocks (Rudnick and Gao, 2003), North American Shale Composite (Gromet et al., 1984), and North American coal (Finkelman, 1993). The pXRF data are in part verified by laboratory results that indicate the mean Y abundance (36 ppm) is highly correlated (R2 = 0.807) with total REE (ΣREE). The correlation is even higher (R2 = 0.957) with heavy REE (ΣHREE). Applying these correlations to the pXRF data for the coal underclays, the mean estimated values for ΣREE+Y and ΣHREE+Y are 270 ppm and 58 ppm, respectively. Although these average values are not considered high, the range of Y measured by pXRF in the coal underclays extended as high as 114 ppm, which would suggest ΣREE+Y equal to 847 ppm. The mean abundances of Zr (192 ppm) and Th (21 ppm) in coal underclays are also enriched compared with the overlying coal and these results likely reflect the presence of resistant detrital heavy minerals such as monazite, xenotime, and zircon in the underclay matrix. Several of the profiled coal seams and associated wall rocks contained thin volcanic ash layers up to 4-5 inches in thickness. The extent to which these ash fall layers provided a source for CM under the paleoenvironmental conditions that resulted in coal deposits in the CAB remains to be fully studied. Continuing investigations in the Evolve CAPP study area will include laboratory determinations of mineralogic and clay compositions, and evaluations of CM geochemical mobility in the coal and coal underclays.

Lassetter, Billy↗

Preparation and characterization of a siloxane containing bismaleimide

A novel siloxane containing bismaleimide has been prepared by reacting maleic anhydride, benzophenonetetracarboxylic dianhydride and bis(gamma-aminopropyl)tetramethyldisiloxane. Characterization of this monomer was done by comparing its nuclear magnetic resonance spectrum (NMR) to those of model compounds. Solubility of the prepolymer was tested in amide, chlorinated and ether solvents. Films were cast from solution as well as by melt processing and a cure cycle was determined. Infrared spectrum (IR) of the resulting film was obtained. Thermal polymerization was investigated by differential scanning calorimetry (DSC). Thermal properties of the cured resin were followed by means of thermogravimetric analysis (TGA), torsional braid analysis (TBA) and dynamic mechanical analysis (DMA). Thermomechanical analysis (TMA) was used to study the effect of postcure on the glass transition temperature (Tg) of the resin. Adhesive strength of the resin was obtained at ambient temperature.

Maudgal, S.↗

IMAGING ANALYSIS OF THE HARD X-RAY TELESCOPE ProtoEXIST2 AND NEW TECHNIQUES FOR HIGH-RESOLUTION CODED-APERTURE TELESCOPES

Wide-field (≳100 deg{sup 2}) hard X-ray coded-aperture telescopes with high angular resolution (≲2′) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

79 ASTRONOMY AND ASTROPHYSICS↗

Microstructural evolution during transient liquid phase bonding of Inconel 738LC using AMS 4777 filler alloy

IN-738LC nickel-based superalloy was joined by transient liquid phase diffusion bonding using AMS 4777 filler alloy. The bonding process was carried out at 1050 Degree-Sign C under vacuum atmosphere for various hold times. Microstructures of the joints were studied by optical and scanning electron microscopy. Continuous centerline eutectic phases, characterized as nickel-rich boride, chromium-rich boride and nickel-rich silicide were observed at the bonds with incomplete isothermal solidification. In addition to the centerline eutectic products, precipitation of boron-rich particles was observed in the diffusion affected zone. The results showed that, as the bonding time was increased to 75 min, the width of the eutectic zone was completely removed and the joint was isothermally solidified. Homogenization of isothermally solidified joints at 1120 Degree-Sign C for 300 min resulted in the elimination of intermetallic phases formed at the diffusion affected zone and the formation of significant {gamma} Prime precipitates in the joint region. - Highlights: Black-Right-Pointing-Pointer TLP bonding of IN-738LC superalloy was performed using AMS 4777 filler alloy. Black-Right-Pointing-Pointer Insufficient diffusion time resulted in the formation of eutectic product. Black-Right-Pointing-Pointer Precipitation of B-rich particles was observed within the DAZ. Black-Right-Pointing-Pointer The extent of isothermal solidification increased with increasing holding time. Black-Right-Pointing-Pointer Homogenizing of joints resulted in the dissolution of DAZ intermetallics.

36 MATERIALS SCIENCE↗