Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Giant terahertz polarization rotation in ultrathin films of aligned carbon nanotubes

For easy manipulation of polarization states of light for applications in communications, imaging, and information processing, an efficient mechanism is desired for rotating light polarization with a minimum interaction length. Here, we report giant polarization rotations for terahertz (THz) electromagnetic waves in ultrathin ( ∼ <#comment/> 45 n m ), high-density films of aligned carbon nanotubes. We observed polarization rotations of up to ∼ <#comment/> 20 ∘ <#comment/> and ∼ <#comment/> 110 ∘ <#comment/> for transmitted and reflected THz pulses, respectively. The amount of polarization rotation was a sensitive function of the angle between the incident THz polarization and the nanotube alignment direction, exhibiting a “magic” angle at which the total rotation through transmission and reflection becomes exactly 90°. Our model quantitatively explains these giant rotations as a result of extremely anisotropic optical constants, demonstrating that aligned carbon nanotubes promise ultrathin, broadband, and tunable THz polarization devices.

Baydin, Andrey (ORCID:0000000225673506)↗

An imaging vector magnetograph for the next solar maximum

Measurements of the vector magnetic field in the solar atmosphere with high spatial and temporal resolution over a large field of view are critical to understanding the nature and evolution of currents in active regions. Such measurements, when combined with the thermal and nonthermal X-ray images from the upcoming Solar-A mission, will reveal the large-scale relationship between these currents and sites of heating and particle acceleration in flaring coronal magnetic flux tubes. The conceptual design of an imaging vector magnetograph that combines a modest solar telescope with a rotating quarter-wave plate, an acousto-optical tunable prefilter as a blocker for a servo-controlled Fabry-Perot etalon, CCD cameras, and a rapid digital tape recorder are described. Its high spatial resolution (1/2 arcsec pixel size) over a large field of view (4 x 5 arcmin) will be sufficient to significantly measure, for the first time, the magnetic energy dissipated in major solar flares. Its millisecond tunability and wide spectra range (5000 to 8000 A) enable nearly simultaneous vector magnetic field measurements in the gas-pressure-dominated photosphere and magnetically dominated chromosphere, as well as effective co-alignment with Solar-A's X-ray images.

Canfield, Richard C.↗

Controlled epitaxial graphene growth within removable amorphous carbon corrals

We address the question of control of the silicon carbide (SiC) steps and terraces under epitaxial graphene on SiC and demonstrate amorphous carbon (aC) corrals as an ideal method to pin SiC surface steps. aC is compatible with graphene growth, structurally stable at high temperatures, and can be removed after graphene growth. For this, aC is first evaporated and patterned on SiC, then annealed in the graphene growth furnace. There at temperatures above 1200 °C, mobile SiC steps accumulate at the aC corral that provide effective step flow barriers. Aligned step free regions are thereby formed for subsequent graphene growth at temperatures above 1330 °C. Atomic force microscopy imaging supports the formation of step-free terraces on SiC with the step morphology aligned to the aC corrals. Raman spectroscopy indicates the presence of good graphene sheets on the step-free terraces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The geometry of signal space: a case study of direct mapping between seismic signals and event distribution

SUMMARY Under favourable circumstances, seismic waveforms corresponding to an ensemble of events related by a common, spatially distributed process collectively exhibit a regular, signal-space geometry. When events in the ensemble have a common, or nearly common, source mechanism, this geometry is a distorted image of the distribution of events in the source region. The signal-space image can be visualized using a relatively simple waveform alignment and projection operation. Ensemble waveform correlation measurements can be inverted to estimate the distribution of the events in the source region, up to an arbitrary rotation, reflection and scaling, with residual distortion. We demonstrate these concepts with synthetic waveforms and with observations of long-wall mining induced seismicity for which substantial ground truth information is available. Our experience with these data has implications for location, correlation detection and machine learning and possible application to studies of repeating events in induced, volcanic and glacial seismicity. Our results place limits on the widely held assumption that waveform correlation is a useful measure of event separation. We suggest that the constraints on event separation need to be evaluated in the context of a population of related events, whose waveforms sample the signal space image of the source region. A better indicator of event separation is the length of the shortest path in signal space along the image.

58 GEOSCIENCES↗

LL18-Signal Analysis-NDD2Ad (Final Report)

Under favorable circumstances, seismic waveforms corresponding to an ensemble of events related by a common, spatially-distributed process collectively exhibit a regular, signal-space geometry. When events in the ensemble have a common, or nearly common, source mechanism, this geometry is a distorted image of the distribution of events in the source region. The signal space image can be visualized using a relatively simple waveform alignment and projection operation. Ensemble waveform correlation measurements can be inverted to estimate the distribution of the events in the source region, up to an arbitrary rotation, reflection, and scaling with residual distortion. We demonstrate these concepts with synthetic waveforms and with observations of long-wall mining induced seismicity for which substantial ground truth information is available. Our experience with these data has implications for location, correlation detection and machine learning, and possible application to studies of repeating events in induced, volcanic, and glacial seismicity. Our results place limits on the widely-held assumption that waveform correlation is a useful measure of event separation. We suggest that the constraints on event separation need to be evaluated in the context of a population of related events, whose waveforms sample the signal space image of the source region. A better indicator of event separation is the length of the shortest path in signal space along the image.

58 GEOSCIENCES↗

Femtosecond X-ray coherent diffraction of aligned amyloid fibrils on low background graphene

Here we present a new approach to diffraction imaging of amyloid fibrils, combining a free-standing graphene support and single nanofocused X-ray pulses of femtosecond duration from an X-ray free-electron laser. Due to the very low background scattering from the graphene support and mutual alignment of filaments, diffraction from tobacco mosaic virus (TMV) filaments and amyloid protofibrils is obtained to 2.7 Å and 2.4 Å resolution in single diffraction patterns, respectively. Some TMV diffraction patterns exhibit asymmetry that indicates the presence of a limited number of axial rotations in the XFEL focus. Signal-to-noise levels from individual diffraction patterns are enhanced using computational alignment and merging, giving patterns that are superior to those obtainable from synchrotron radiation sources. In conclusion, we anticipate that our approach will be a starting point for further investigations into unsolved structures of filaments and other weakly scattering objects.

47 OTHER INSTRUMENTATION↗

Joint high temperature observation of a small C6.5 solar flare with IRIS/EIS/AIA

We present the observation of a C6.5 class flare on 2014 February 3, obtained with the Interface Region Imaging Spectrograph (IRIS) and the EUV Imaging Spectrometer (EIS) on board HINODE. We follow the details of the impulsive phase with IRIS and the gradual decay phase with both IRIS and EIS. The IRIS Slit-Jaw Imager and Atmospheric Imaging Assembly (AIA) are used to precisely co-align the two sets of spectroscopic observations. Of particular interest is the Fe xxi 1354.08 Å spectral line, which is the highest temperature emission (∼10 MK) observed in the IRIS wavelength range. We show the evolution of the Fe xxi profiles during the impulsive phase of the flare at the same ribbon location with a 75 s temporal cadence. Totally blueshifted (∼82 km s{sup −1}) profiles are found at the very early phase of the flare and gradually decrease in about 6 minutes. This result is consistent with 1D model predictions during chromospheric evaporation in flares. The blueshifted components also exhibit large non-thermal broadening, which decreases simultaneously with the blueshifted velocity. After the evaporation first occurs, the Fe xxi intensity progressively moves from the footpoints to the top of the hot flare loops seen in the AIA 131 Å images, where the emission is observed to be at rest and thermal. Emission measure estimates from IRIS/EIS/AIA observations during the gradual phase show isothermal loop top structures cooling from about 13.5 to 12 MK with electron densities of the order of ∼5−6×10{sup 10} cm{sup −3}.

79 ASTRONOMY AND ASTROPHYSICS↗

Photodetector Arrays for Multicolor Visible/Infrared Imaging

Monolithic focal-plane arrays of photodetectors capable of imaging the same scenes simultaneously in multiple wavelength bands in the visible and infrared spectral regions have been proposed. In prior visible/infrared imaging systems, it has been standard practice to use separate optical trains to form images in visible and infrared wavelength bands on separate visibleand infrared-photodetector arrays. Because the proposal would enable the detection of images in multiple wavelength bands on the same focal plane, the proposal would make it unnecessary to use multiple optical trains. Hence, multispectral imaging systems could be made more compact and the difficulties of aligning multiple optical trains would be eliminated. Each pixel in an array according to the proposal would contain stacks of several photodetectors. The proposal is a logical extension of prior concepts of arrays of stacked photodetectors for imaging in two or three wavelength bands. For example, such an array was described in Three-Color Focal-Plane Array of Infrared QWIPs (NPO-20683), NASA Tech Briefs, Vol. 24, No. 5 (May 2000), page 26a. In one proposed design, (see figure), each pixel would be divided into four subpixels, one being dedicated to a visible- and-near-infrared (V) band, one to a combination of the V band and a verylong- wavelength infrared (VLWIR) band, one to a combination of the V band and a long-wavelength infrared (LWIR) band, and one to a combination of the V band and a medium-wavelength infrared (MWIR) band. For this purpose, each subpixel would include a GaAs-based positive/intrinsic/negative (PIN) photodiode for detection in the V band stacked with three quantum-well infrared photodetectors (QWIPs), each optimized for one of the aforementioned infrared bands. The stacks of photodetectors in all the subpixels would be identical except for the electrical connections, which would be configured to activate the various wavelengthband combinations.

Gunapala, Sarath↗

EVOLUTION OF THE 1919 EJECTA OF V605 AQUILAE

New imaging of V605 Aql, was obtained in 2009 with HST/WFPC2, which had a nova-like outburst in 1919, and is located at the center of the planetary nebula (PN), A58. This event has long been ascribed to a final helium shell flash, but it has been suggested recently that it may instead have been an ONe nova. The new images provide an 18 yr baseline for the expansion of the ejecta from the 1919 event. In addition, the central star has been directly detected in the visible for the first time since 1923, when it faded from sight due to obscuration by dust. The expansion of the ejecta has a velocity of {approx}200 km s{sup -1}, and an angular expansion rate of {approx}10 mas yr{sup -1}, consistent with a 1919 ejection. This implies a geometric distance of 4.6 kpc for V605 Aql, consistent with previous estimates. The gas mass in the central knot of ejecta was previously estimated to be 5 Multiplication-Sign 10{sup -5} M{sub Sun }. It is estimated that warm dust associated with this gas has a mass of {approx}10{sup -5} M{sub Sun }. There is also evidence for a significant amount, 10{sup -3} M{sub Sun }, of cold (75 K) dust, which may be associated with its PN. The knot ejected in 1919 is asymmetrical and is approximately aligned with the asymmetry of the surrounding PN. Polarimetric imaging was obtained to investigate whether the 2001 spectrum of V605 Aql was obtained primarily in scattered light from dust in the central knot, but the signal-to-noise in the data was insufficient to measure the level of polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of X-ray imaging techniques to auroral monitoring

The precipitation of energetic particles into the ionosphere produces bremsstrahlung X-rays and K-alpha line emission from excited oxygen and nitrogen. If viewed from a spacecraft in a highly elliptical polar orbit, this soft (0.3 - 3.0 keV) X-radiation will provide an almost uninterrupted record of dayside and nightside auroras. A grazing incidence X-ray telescope especially designed for such auroral monitoring is described. High photon collection efficiency will permit exposure times of approximately 100 seconds during substorms. Spectrophotometry will allow users to derive the energy spectrum of the precipitating particles. If placed in a 15 earth-radius orbit, the telescope can produce auroral X-ray images with 30 km resolution. Absolute position of X-ray auroras can be established with a small optical telescope co-aligned with the X-ray telescope. Comparison of X-ray and optical images will establish the height and global distribution of X-ray aurorae, relative to well-known optical auroras, thus melding the new X-ray results with knowledge of optical auroras.

Rust, D. M.↗

Wavefront Sensing for WFIRST with a Linear Optical Model

In this paper we develop methods to use a linear optical model to capture the field dependence of wavefront aberrations in a nonlinear optimization-based phase retrieval algorithm for image-based wavefront sensing. The linear optical model is generated from a ray trace model of the system and allows the system state to be described in terms of mechanical alignment parameters rather than wavefront coefficients. This approach allows joint optimization over images taken at different field points and does not require separate convergence of phase retrieval at individual field points. Because the algorithm exploits field diversity, multiple defocused images per field point are not required for robustness. Furthermore, because it is possible to simultaneously fit images of many stars over the field, it is not necessary to use a fixed defocus to achieve adequate signal-to-noise ratio despite having images with high dynamic range. This allows high performance wavefront sensing using in-focus science data. We applied this technique in a simulation model based on the Wide Field Infrared Survey Telescope (WFIRST) Intermediate Design Reference Mission (IDRM) imager using a linear optical model with 25 field points. We demonstrate sub-thousandth-wave wavefront sensing accuracy in the presence of noise and moderate undersampling for both monochromatic and polychromatic images using 25 high-SNR target stars. Using these high-quality wavefront sensing results, we are able to generate upsampled point-spread functions (PSFs) and use them to determine PSF ellipticity to high accuracy in order to reduce the systematic impact of aberrations on the accuracy of galactic ellipticity determination for weak-lensing science.

Jurling, Alden S.↗

Data clustering for the high-resolution alignment of microstructure and strain fields

The emergence of small-scale deformation mapping by a combination of scanning electron microscopy and digital image correlation (SEM-DIC) has enabled full-field investigations into the complex roles of microstructure on microscale deformation mechanisms. However, these investigations are hindered by errors in alignment between the microstructure data, generally acquired by electron backscatter diffraction (EBSD), and the microscale strain data obtained by SEM-DIC. Distortions, stitching artifacts, and spatial resolution differences between microstructure and strain fields can lead to misalignments on the order of μms. This alignment uncertainty introduces error into microstructure-strain localization analyses and precludes the examination of deformation mechanisms near grain boundaries. To improve alignment between EBSD-obtained grain boundaries and SEM-DIC strain data, an approach was created wherein a mantle was first established around the EBSD-acquired grain boundaries. Strain data was then clustered within this mantle using a k-means algorithm to identify grain boundary strain localization, and these boundary points were fit to obtain a continuous curve for each individual boundary. Clustered point outliers, such as those due to grain boundary-local dislocation slip, were statistically identified by using an absolute error threshold and removed from the grain boundary fit. The ending identification of grain boundaries in the microscale strain data is significantly improved from EBSD-identified boundaries.

36 MATERIALS SCIENCE↗

Multi-Scale Dynamics, Control, and Simulation of Granular Spacecraft

In this paper, we present some ideas regarding the modeling, dynamics and control aspects of granular spacecraft. Granular spacecraft are complex multibody systems composed of a spatially disordered distribution of a large number of elements, for instance a cloud of grains in orbit. An example of application is a spaceborne observatory for exoplanet imaging, where the primary aperture is a cloud instead of a monolithic aperture. A model is proposed of a multi-scale dynamics of the grains and cloud in orbit, as well as a control approach for cloud shape maintenance and alignment, and preliminary simulation studies are carried out for the representative imaging system.

granular media↗

Dynamics and Control of a Disordered System in Space

In this paper, we present some ideas regarding the modeling, dynamics and control aspects of granular spacecraft. Granular spacecraft are complex multibody systems composed of a spatially disordered distribution of a large number of elements, for instance a cloud of grains in orbit. An example of application is a spaceborne observatory for exoplanet imaging, where the primary aperture is a cloud instead of a monolithic aperture. A model is proposed of the multi-scale dynamics of the grains and cloud in orbit, as well as a control approach for cloud shape maintenance and alignment, and preliminary simulation studies are carried out for the representative imaging system.

granular matter↗

Dynamics and Control of Granular Imaging Systems

In this paper, we present some ideas regarding the modeling, dynamics and control aspects of granular spacecraft. Granular spacecraft are complex multibody systems composed of a spatially disordered distribution of a large number of elements, for instance a cloud of grains in orbit. An example of application is a spaceborne observatory for exoplanet imaging, where the primary aperture is a cloud instead of a monolithic aperture. A model is proposed of the multi-scale dynamics of the grains and cloud in orbit, as well as a control approach for cloud shape maintenance and alignment, and preliminary simulation studies are carried out for the representative imaging system.

optical trapping↗

Hexagonal Pixels and Indexing Scheme for Binary Images

A scheme for resampling binaryimage data from a rectangular grid to a regular hexagonal grid and an associated tree-structured pixel-indexing scheme keyed to the level of resolution have been devised. This scheme could be utilized in conjunction with appropriate image-data-processing algorithms to enable automated retrieval and/or recognition of images. For some purposes, this scheme is superior to a prior scheme that relies on rectangular pixels: one example of such a purpose is recognition of fingerprints, which can be approximated more closely by use of line segments along hexagonal axes than by line segments along rectangular axes. This scheme could also be combined with algorithms for query-image-based retrieval of images via the Internet. A binary image on a rectangular grid is generated by raster scanning or by sampling on a stationary grid of rectangular pixels. In either case, each pixel (each cell in the rectangular grid) is denoted as either bright or dark, depending on whether the light level in the pixel is above or below a prescribed threshold. The binary data on such an image are stored in a matrix form that lends itself readily to searches of line segments aligned with either or both of the perpendicular coordinate axes. The first step in resampling onto a regular hexagonal grid is to make the resolution of the hexagonal grid fine enough to capture all the binaryimage detail from the rectangular grid. In practice, this amounts to choosing a hexagonal-cell width equal to or less than a third of the rectangular- cell width. Once the data have been resampled onto the hexagonal grid, the image can readily be checked for line segments aligned with the hexagonal coordinate axes, which typically lie at angles of 30deg, 90deg, and 150deg with respect to say, the horizontal rectangular coordinate axis. Optionally, one can then rotate the rectangular image by 90deg, then again sample onto the hexagonal grid and check for line segments at angles of 0deg, 60deg, and 120deg to the original horizontal coordinate axis. The net result is that one has checked for line segments at angular intervals of 30deg. For even finer angular resolution, one could, for example, then rotate the rectangular-grid image +/-45deg before sampling to perform checking for line segments at angular intervals of 15deg.

Johnson, Gordon G.↗

Nitrogen-induced reconstructions on the Cr(001) surface

Here, we use spin-polarized density functional theory to describe the surface reconstructions formed when the Cr(001) surface is exposed to nitrogen. Our primary goal is to clarify the atomic structure of the N induced c(2x2) Cr(001) reconstruction and to study its properties. After analyzing the relative stability of several models with a ½ monolayer of N atoms on the surface, it was found that only two models were stable for different growth conditions. The first stable model shows two N atoms (per cell) adsorbed on hollow sites following a diagonal pattern. In the second, N atoms replace Cr atoms of the first monolayer, and after optimization, they end up in almost second layer positions. To compare with scanning tunneling microscopy experiments, simulated STM images, using the Tersoff-Hamann approximation, were obtained. Our two models can explain the two different c(2x2) Cr(001) reconstructions observed experimentally. The magnetic properties, such as magnetic moments and alignments, are discussed compared with experimental values.

36 MATERIALS SCIENCE↗

SU-E-J-263: Dosimetric Analysis On Breast Brachytherapy Based On Deformable Image Registration

Purpose: To quantitatively compare and evaluate the dosimetry difference between breast brachytherapy protocols with different fractionation using deformable image registration. Methods: The accumulative dose distribution for multiple breast brachytherapy patients using four different applicators: Contura, Mammosite, Savi, and interstitial catheters, under two treatment protocols: 340cGy by 10 fractions in 5 days and 825cGy by 3 fractions in 2days has been reconstructed using a two stage deformable image registration approach. For all patients, daily CT was acquired with the same slice thickness (2.5mm). In the first stage, the daily CT images were rigidly registered to the initial planning CT using the registration module in Eclipse (Varian) to align the applicators. In the second stage, the tissues surrounding the applicator in the rigidly registered daily CT image were non-rigidly registered to the initial CT using a combination of image force and the local constraint that enforce zero normal motion on the surface of the applicator, using a software developed in house. We calculated the dose distribution in the daily CTs and deformed them using the final registration to convert into the image domain of the initial planning CT. The accumulative dose distributions were evaluated by dosimetry parameters including D90, V150 and V200, as well as DVH. Results: Dose reconstruction results showed that the two day treatment has a significant dosimetry improvement over the five day protocols. An average daily drop of D90 at 1.3% of the prescription dose has been observed on multiple brachytherapy patients. There is no significant difference on V150 and V200 between those two protocols. Conclusion: Brachytherapy with higher fractional dose and less fractions has an improved performance on being conformal to the dose distribution in the initial plan. Elongated brachytherapy treatments need to consider the dose uncertainty caused by the temporal changes of the soft tissue.

60 APPLIED LIFE SCIENCES↗