Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Laser photodetachment diagnostics of a 1/3-size negative hydrogen ion source for NBI

To investigate the flows of charged particles in front of the plasma grid (PG) in a negative hydrogen ion source, the information of the local densities of electrons and negative hydrogen ions (H-) are necessary. For this purpose, the laser photodetachment is applied for pure hydrogen plasmas and Cs-seeded plasma in a 1/3-size negative hydrogen ion source in NIFS-NBI test stand. The H- density obtained by photodetachment is calibrated by the results from cavity ring-down (CRD). The pressure dependence and PG bias dependence of the local H- density are presented and discussed. The results show that H- density increases significantly by seeding Cs into the plasma. In Cs-seeded plasma, relativity exists between the H- ion density and plasma potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extracted current saturation in negative ion sources

The extraction of negatively charged particles from a negative ion source is one of the crucial issues in the development of the neutral beam injector system for future experimental reactor ITER. Full 3D electrostatic particle-in-cell Monte Carlo collision code - ONIX [S. Mochalskyy et al., Nucl. Fusion 50, 105011 (2010)] - is used to simulate the hydrogen plasma behaviour and the extracted particle features in the vicinity of the plasma grid, both sides of the aperture. It is found that the contribution to the extracted negative ion current of ions born in the volume is small compared with that of ions created at the plasma grid walls. The parametric study with respect to the rate of negative ions released from the walls shows an optimum rate. Beyond this optimum, a double layer builds-up by the negative ion charge density close to the grid aperture surface reducing thus extraction probability, and therefore the extracted current. The effect of the extraction potential and magnetic field magnitudes on the extraction is also discussed. Results are in good agreement with available experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heavy-ion injector based on an electron cyclotron ion source for the superconducting linear accelerator of the Rare Isotope Science Project

The injector for the main driver linear accelerator of the Rare Isotope Science Project in Korea, has been developed to allow heavy ions up to uranium to be delivered to the inflight fragmentation system. The critical components of the injector are the superconducting electron cyclotron resonance (ECR) ion sources, the radio frequency quadrupole (RFQ), and matching systems for low and medium energy beams. We have built superconducting magnets for the ECR ion source, and a prototype with one segment of the RFQ structure, with the aim of developing a design that can satisfy our specifications, demonstrate stable operation, and prove results to compare the design simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities

Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space available for the optimization of high charge state ion currents. The most critical parameter in terms of plasma stability is the strength of the solenoid magnetic field. It is demonstrated that due to the instabilities the optimum B{sub min}-field in single frequency heating mode is often ≤0.8B{sub ECR}, which is the value suggested by the semiempirical scaling laws guiding the design of modern ECRISs. It is argued that the effect can be attributed not only to the absolute magnitude of the magnetic field but also to the variation of the average magnetic field gradient on the resonance surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A HIGH CURRENT DENSITY LI+ ALUMINO-SILICATE ION SOURCE FOR TARGET HEATING EXPERIMENTS

The NDCX-II accelerator for target heating experiments has been designed to use a large diameter ({approx_equal} 10.9 cm) Li{sup +} doped alumino-silicate source with a pulse duration of 0.5 {micro}s, and beam current of {approx_equal} 93 mA. Characterization of a prototype lithium alumino-silicate sources is presented. Using 6.35mm diameter prototype emitters (coated on a {approx_equal} 75% porous tungsten substrate), at a temperature of {approx_equal} 1275 C, a space-charge limited Li{sup +} beam current density of {approx_equal} 1 mA/cm{sup 2} was measured. At higher extraction voltage, the source is emission limited at around {approx_equal} 1.5 mA/cm{sup 2}, weakly dependent on the applied voltage. The lifetime of the ion source is {approx_equal} 50 hours while pulsing the extraction voltage at 2 to 3 times per minute. Measurements show that the life time of the ion source does not depend only on beam current extraction, and lithium loss may be dominated by neutral loss or by evaporation. The life time of a source is around {ge} 10 hours in a DC mode extraction, and the extracted charge is {approx_equal} 75% of the available Li in the sample. It is inferred that pulsed heating may increase the life time of a source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High voltage holding in the negative ion sources with cesium deposition

High voltage holding of the large surface-plasma negative ion source with cesium deposition was studied. It was found that heating of ion-optical system electrodes to temperature >100 °C facilitates the source conditioning by high voltage pulses in vacuum and by beam shots. The procedure of electrode conditioning and the data on high-voltage holding in the negative ion source with small cesium seed are described. The mechanism of high voltage holding improvement by depletion of cesium coverage is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Ion Source Development at HRIBF

This report describes the efforts made to develop a resonant-ionization laser ion source based on tunable Ti:Sapphire lasers for nuclear physics and astrophysics research at HRIBF. Three Ti:Sapphire lasers have been upgraded with individual pump lasers to eliminate laser power losses due to synchronization delays. Ionization schemes for 14 elements have been obtained. Off-line studies show that the overall efficiency of the laser ion source can be as high as 40%. TaC surface coatings have been investigated for minimizing surface and bulk trapping of the atoms of interest.

Liu, Yuan↗

A low energy ion source for electron capture spectroscopy

We report on the design of an ion source for the production of single and double charged Helium ions with kinetic energies in the range from 300 eV down to 5 eV. The construction is based on a commercial sputter ion gun equipped with a Wien-filter for mass/charge separation. Retardation of the ions from the ionizer potential (2 keV) takes place completely within the lens system of the sputter gun, without modification of original parts. For 15 eV He{sup +} ions, the design allows for beam currents up to 30 nA, limited by the space charge repulsion in the beam. For He{sup 2+} operation, we obtain a beam current of 320 pA at 30 eV, and 46 pA at 5 eV beam energy, respectively. In addition, operating parameters can be optimized for a significant contribution of metastable He*{sup +} (2s) ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of positive ions on the surface production of negative ions in a fusion plasma reactor type negative ion source—Insights from a three dimensional particle-in-cell Monte Carlo collisions model

Results from a 3D self-consistent Particle-In-Cell Monte Carlo Collisions (PIC MCC) model of a high power fusion-type negative ion source are presented for the first time. The model is used to calculate the plasma characteristics of the ITER prototype BATMAN ion source developed in Garching. Special emphasis is put on the production of negative ions on the plasma grid surface. The question of the relative roles of the impact of neutral hydrogen atoms and positive ions on the cesiated grid surface has attracted much attention recently and the 3D PIC MCC model is used to address this question. The results show that the production of negative ions by positive ion impact on the plasma grid is small with respect to the production by atomic hydrogen or deuterium bombardment (less than 10%)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion source and beam guiding studies for an API neutron generator

Recently developed neutron imaging methods require high neutron yields for fast imaging times and small beam widths for good imaging resolution. For ion sources with low current density to be viable for these types of imaging methods, large extraction apertures and beam focusing must be used. We present recent work on the optimization of a Penning-type ion source for neutron generator applications. Two multi-cusp magnet configurations have been tested and are shown to increase the extracted ion current density over operation without multi-cusp magnetic fields. The use of multi-cusp magnetic confinement and gold electrode surfaces have resulted in increased ion current density, up to 2.2 mA/cm{sup 2}. Passive beam focusing using tapered dielectric capillaries has been explored due to its potential for beam compression without the cost and complexity issues associated with active focusing elements. Initial results from first experiments indicate the possibility of beam compression. Further work is required to evaluate the viability of such focusing methods for associated particle imaging (API) systems.

43 PARTICLE ACCELERATORS↗

Negative ion production and beam extraction processes in a large ion source (invited)

Recent research results on negative-ion-rich plasmas in a large negative ion source have been reviewed. Spatial density and flow distributions of negative hydrogen ions (H{sup −}) and positive hydrogen ions together with those of electrons are investigated with a 4-pin probe and a photodetachment (PD) signal of a Langmuir probe. The PD signal is converted to local H{sup −} density from signal calibration to a scanning cavity ring down PD measurement. Introduction of Cs changes the slope of plasma potential local distribution depending upon the plasma grid bias. A higher electron density H{sub 2} plasma locally shields the bias potential and behaves like a metallic free electron gas. On the other hand, the bias and extraction electric fields penetrate in a Cs-seeded electronegative plasma even when the electron density is similar. Electrons are transported by the penetrated electric fields from the driver region along and across the filter and electron deflection magnetic fields. Plasma ions exhibited a completely different response against the penetration of electric fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long Pulse H{sup -} Beam Extraction With A RF Driven Ion Source With Low Fraction Of Co-Extracted Electrons

IPP Garching is developing H{sup -}/D{sup -} RF ion sources for the ITER neutral beam system. On the MANITU testbed the experiments are focussed on long pulse H{sup -}/D{sup -} beam extraction with a 100 kW prototype source. The negative ion production is based on surface conversion of atoms and positive ions on Caesium layers. In long pulses with H{sup -} beam extraction the ion currents were stable but with too high fraction of co-extracted electrons. The electron current could be lowered considerably by avoiding copper impurities from the Faraday screen in the plasma which was achieved by coating of the inner surfaces of the source with Molybdenum. A positive bias potential with respect to the source applied to the plasma grid, the bias plate or to a metal rod installed near the plasma grid enables regulation of the electron current during long pulses. In this way low values consistent with the ITER requirements can be achieved without significant loss of ion current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of a Structure for Assembly and Cooling the Magnet of the Next-Generation 45 GHz ECR Ion Source MARS-D

Here, the current Electron Cyclotron Resonance Ion Sources (ECRISs), constructed with Nb-Ti wires and the conventional racetrack-and-solenoid structure, have achieved operating frequencies up to 28 GHz and utilized about 90% of the critical current of the Nb-Ti wire. A Mixed Axial and Radial field System Demonstrator (MARS-D) is being developed at Lawrence Berkeley National Laboratory (LBNL). This system, which consists of an innovative hexagonal Closed-Loop Coil (CLC) and a set of solenoids, can generate higher magnetic fields (up to 150% ) while requiring only about 50% of the superconducting wire, enabling Nb-Ti wires to be used in the next-generation 45 GHz ECRIS. However, the assembly and cooling of such an efficient and compact magnet are particularly challenging due to the small radial gap between the CLC and solenoids, as well as the tight operating temperature margin. To address these challenges, a structure was developed that combines a three-section radially split solenoid mandrel with a series of shrink-fit reinforcement rings and cooling channels. This paper presents the detailed structure, manufacturing method, assembly procedure, impregnation method, mechanical Finite Element Analysis (FEA) comparison, and thermal FEA comparison.

ECR ion sources↗

Negative Hydrogen Ion Source with Inverse Gas Magnetron Geometry

The work is dedicated to the experimental investigation of the intense volume-plasma H{sup -} ion source. Formation of ions occurs in a volume of hydrogen plasma (without additives of cesium) due to two-step dissociative attachment of thermal electrons to vibrationally excited molecules H{sub 2}. Preliminary experimental researches of two parameters of the upgraded source--emission density of H{sup -} ions and gas flow are represented below. The advancing of electrode system of the emission chamber of a source has allowed receiving the value of an emission density of H{sup -} ions equal 440 mA/cm{sup 2}.

43 PARTICLE ACCELERATORS↗

Status of the new SNS injector and external antenna ion source

The U.S. Spallation Neutron Source (SNS) now operates with 1.2 MW of beam power on target with the near-term goal of delivering 1.4 MW and a longer-term goal of delivering >2 MW required by the planned Proton Power Upgrade (PPU) and Second Target Station (STS) projects. In early 2018 we plan to replace the entire 2.5 MeV injector configuration which includes the ion source, the Low Energy Beam Transport (LEBT) and the Radio Frequency Quadrupole accelerator (RFQ) with one which is currently being tested on a research accelerator called the Beam Test Facility (BTF) located at the SNS facility. This report first provides a description of the new injector: the ion source and the cage enclosure, the new LEBT support structure and the new RFQ. Since fall of 2016, this system has been tested extensively with regard to output beam current, beam persistence, emittance and energy. The results of these experiments employing both internal and external antenna ion sources will be summarized here showing the system to be capable of supporting SNS 1.4 MW operations with a significant margin as well as potentially meeting facility upgrade requirements. This represents a significant performance upgrade over the current SNS front end system with the compromised RFQ and will replace that system in early 2018.

Welton, Robert F.↗

Demagnetization analysis of an 18 GHz electron cyclotron resonance ion source permanent magnet hexapole

An upgrade of ECR2 at the Argonne Tandem Linac Accelerator System is under way, focusing on increasing the intensity capabilities of the facility. ECR2 is a room temperature electron cyclotron resonance ion source, and the upgrade has strict requirements to retain radial access to the plasma chamber and keep the ion source operating without the use of superconducting magnets. The upgrade design with respect to the magnet arrangement and magnetization vectors has recently been presented [R. C. Vondrasek, J. McLain, and R. H. Scott, J. Phys.: Conf. Ser. 2743 , 012044 (2024)] using the same magnetic material as the current ECR2 hexapole. A thorough exploration of the demagnetization potential of this hexapole was carried out, and the risk of demagnetization was deemed too high, despite the magnetic performance meeting the requirements for the upgrade. Additional permanent magnet materials are considered with their respective performance evaluated. Magnet strength and demagnetization resistance are investigated and optimized with the final room temperature design demonstrating a high temperature transient demagnetization resistance and a radial magnetic field of 1.18 T at the plasma chamber wall. Finally, the simulations of this hexapole suggest that it will be sufficient to optimize intensity with a 14.5 GHz driving frequency and will allow 18 GHz operation, while keeping a high safety margin for maintaining magnet performance.

Argonne Tandem Linac Accelerator System↗

Commissioning of Extended Electron Beam Ion Source at Brookhaven National Laboratory

Here, the Extended Electron Beam Ion Source (EEBIS) has been installed and commissioned at Brookhaven National Laboratory (BNL) hadron accelerator complex in the spring of 2023. EEBIS has replaced its predecessor, RhicEBIS, which provided ions for BNL hadron facilities for over a decade since 2009. The motivations for the source upgrade are to provide higher intensities of the Au 32+ ion beam for the Relativistic Heavy Ion Collider (RHIC) and to provide of an intense source of polarized 3 He 2+ ions for the future Electron Ion Collider (EIC) at BNL. EEBIS is and will continue to be the primary source for a variety of different ion species for the NASA Space Radiation Laboratory (NSRL) at BNL. EEBIS utilizes two identical, two-meter-long unshielded 5T warm bore superconducting solenoids, and it is operated with electron beam current up to 10 A, providing a high-capacity ion traps to fulfill the requirement for high intensity ion beams. The upstream solenoid contains a “short ion trap” with a length of 95 cm, while the “long ion trap” with a length of 178 cm is located inside the downstream solenoid bore. The main features of EEBIS are: * A Gas injection and ionization cell equipped with a Lorenz pulse valve * High-capacity ZAO non-evaporable getter (NEG) custom linear pumping units * In situ apparatus for pumping speed measurements to monitor NEG activation and saturation * “External drift tube” construction with differential pumping stages to provide space for Lorentz pulse valve and 3 He high-field polarization cell * A Ba oxide electron gun cathode. The design of EEBIS as well as the results of its commissioning and first-year operation are presented and discussed.

43 PARTICLE ACCELERATORS↗