Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

CHARACTERIZATION OF THE INNER DISK AROUND HD 141569 A FROM KECK/NIRC2 L-BAND VORTEX CORONAGRAPHY

HD 141569 A is a pre-main sequence B9.5 Ve star surrounded by a prominent and complex circumstellar disk, likely still in a transition stage from protoplanetary to debris disk phase. Here, we present a new image of the third inner disk component of HD 141569 A made in the L ′ band (3.8 μ m) during the commissioning of the vector vortex coronagraph that has recently been installed in the near-infrared imager and spectrograph NIRC2 behind the W.M. Keck Observatory Keck II adaptive optics system. We used reference point-spread function subtraction, which reveals the innermost disk component from the inner working distance of ≃23 au and up to ≃70 au. The spatial scale of our detection roughly corresponds to the optical and near-infrared scattered light, thermal Q , N , and 8.6 μ m PAH emission reported earlier. We also see an outward progression in dust location from the L ′ band to the H band (Very Large Telescope/SPHERE image) to the visible ( Hubble Space Telescope ( HST )/STIS image), which is likely indicative of dust blowout. The warm disk component is nested deep inside the two outer belts imaged by HST-NICMOS in 1999 (at 406 and 245 au, respectively). We fit our new L ′-band image and spectral energy distribution of HD 141569 A with the radiative transfer code MCFOST. Our best-fit models favor pure olivine grains and are consistent with the composition of the outer belts. While our image shows a putative very faint point-like clump or source embedded in the inner disk, we did not detect any true companion within the gap between the inner disk and the first outer ring, at a sensitivity of a few Jupiter masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatiotemporal evolution of runaway electrons from synchrotron images in Alcator C-Mod

In the Alcator C-Mod tokamak, relativistic runaway electron (RE) generation can occur during the flattop current phase of low density, diverted plasma discharges. Due to the high toroidal magnetic field (B0 = 5.4 T), RE synchrotron radiation is measured by a wide-view camera in the visible wavelength range (~400-900 nm). In this paper, a statistical analysis of over one thousand camera images is performed to investigate the plasma conditions under which synchrotron emission is observed in C-Mod. In addition, the spatiotemporal evolution of REs during one particular discharge is explored in detail via a thorough analysis of the distortion-corrected synchrotron images. To accurately predict RE energies, the kinetic solver CODE [Landreman et al 2014 Comput. Phys. Commun. 185 847-855] is used to evolve the electron momentum-space distribution at six locations throughout the plasma: the magnetic axis and flux surfaces q = 1, 4/3, 3/2, 2, and 3. These results, along with the experimentally-measured magnetic topology and camera geometry, are input into the synthetic diagnostic SOFT [Hoppe et al 2018 Nucl. Fusion 58 026032] to simulate synchrotron emission and detection. Interesting spatial structure near the surface q = 2 is found to coincide with the onset of a locked mode and increased MHD activity. Furthermore, the RE density profile evolution is fit by comparing experimental to synthetic images, providing important insight into RE spatiotemporal dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BFSVBF (BatFinder Smart Video BioFilter) [SWR-22-87] and Multi-class BatFinder Smart Video BioFilter Keras

Bats are notoriously difficult to study, therefore, identifying specific behavioral trends and the precise environmental conditions at the time of collision requires a monitoring solution that can reliably collect relevant data. To date, thermal infrared video surveillance has been extensively applied to study bats and has proven to be a powerful yet cumbersome tool. Current analytical approaches are time consuming because data processing data has not been fully automated. In the past, steps have been taken to record avian and bat activity in conjunction with complicated image processing techniques that separate species from other moving objects within the field of view (i.e. clouds and portions of the wind turbine). Once the videos are collected, the post-processing does not allow real time monitoring and identification, leading to a delay in both studying the behavior of these species and determining the effectiveness of any impact reduction strategy being studied. Moreover, object identification capability is lacking, thus limiting the usefulness of video data. To resolve these issues, we are using open source computer vision and machine learning techniques allowing for automatic detection of objects in real-time with the ability to correlate these objects with environmental variables and recording the flight paths of each object. The code has gone through five rounds of development with images used to train the models. This advancement allows for automated real-time data collection, identification, and tracking, thereby eliminating the need for long and tedious post-analysis processing of the videos. We will discuss the two open source and publicly available machine learning models developed within this scope of this work: 1) a binary model with a 97.5% accuracy in identifying the difference between an object and an empty scene, including wind turbine and clouds; and 2) a multiple classification model with the capability of identifying the type of object detected: bats (90% accuracy), birds (83% accuracy), insects (69% accuracy) and non-biological (99% accuracy).

Yarbrough, John↗

PANCHROMATIC IMAGING OF A TRANSITIONAL DISK: THE DISK OF GM AUR IN OPTICAL AND FUV SCATTERED LIGHT

We have imaged GM Aurigae with the Hubble Space Telescope , detected its disk in scattered light at 1400 and 1650 Å, and compared these with observations at 3300 Å, 5550 Å, 1.1 μ m, and 1.6 μ m. The scattered light increases at shorter wavelengths. The radial surface brightness profile at 3300 Å shows no evidence of the 24 au radius cavity that has been previously observed in submillimeter observations. Comparison with dust grain opacity models indicates that the surface of the entire disk is populated with submicron grains. We have compiled a spectral energy distribution from 0.1 μ m to 1 mm and used it to constrain a model of the star + disk system that includes the submillimeter cavity using the Monte Carlo radiative transfer code by Barbara Whitney. The best-fit model image indicates that the cavity should be detectable in the F330W bandpass if the cavity has been cleared of both large and small dust grains, but we do not detect it. The lack of an observed cavity can be explained by the presence of submicron grains interior to the submillimeter cavity wall. We suggest one explanation for this that could be due to a planet of mass <9 M {sub J} interior to 24 au. A unique cylindrical structure is detected in the far-UV data from the Advanced Camera for Surveys/Solar Blind Channel. It is aligned along the system semiminor axis, but does not resemble an accretion-driven jet. The structure is limb brightened and extends 190 ± 35 au above the disk midplane. The inner radius of the limb brightening is 40 ± 10 au, just beyond the submillimeter cavity wall.

79 ASTRONOMY AND ASTROPHYSICS↗

HipGISAXS : a high-performance computing code for simulating grazing-incidence X-ray scattering data

This article describes the development of a flexible grazing-incidence small-angle X-ray scattering (GISAXS) simulation code in the framework of the distorted wave Born approximation that effectively utilizes the parallel processing power provided by graphics processors and multicore processors. The code, entitled High-Performance GISAXS , computes the GISAXS image for any given superposition of user-defined custom shapes or morphologies in a material and for various grazing-incidence angles and sample orientations. These capabilities permit treatment of a wide range of possible sample structures, including multilayered polymer films and nanoparticles on top of or embedded in a substrate or polymer film layers. In cases where the material displays regions of significant refractive index contrast, an algorithm has been implemented to perform a slicing of the sample and compute the averaged refractive index profile to be used as the reference geometry of the unperturbed system. A number of case studies are presented, which demonstrate good agreement with the experimental data for a variety of polymer and hybrid polymer/nanoparticle composite materials. The parallelized simulation code is well suited for addressing the analysis efforts required by the increasing amounts of GISAXS data being produced by high-speed detectors and ultrafast light sources.

Chemistry↗

SU-E-J-08: Comparison of Unintended Radiation Doses to Organs at Risk Resulting From the Out-Of-Field Therapeutic Beams and From Image-Guidance X-Ray Procedures

Purpose: The unintended radiation dose to organs at risk (OAR) can be contributed from imaging guidance procedures as well as from leakage and scatter of therapeutic beams. This study compares the imaging dose with the unintended out-of-field therapeutic dose to patient sensitive organs. Methods: The Monte Carlo EGSnrc user codes, BEAMnrc and DOSXYZnrc, were used to simulate kV X-ray sources from imaging devices as well as the therapeutic IMRT/VMAT beams and to calculate doses to target and OARs on patient treatment planning CT images. The accuracy of the Monte Carlo simulations was benchmarked against measurements in phantoms. The dose-volume histogram was utilized in analyzing the patient organ doses. Results: The dose resulting from Standard Head kV-CBCT scans to bone and soft tissues ranges from 0.7 to 1.1 cGy and from 0.03 to 0.3 cGy, respectively. The dose resulting from Thorax scans on the chest to bone and soft tissues ranges from 1.1 to 1.8 cGy and from 0.3 to 0.6 cGy, respectively. The dose resulting from Pelvis scans on the abdomen to bone and soft tissues range from 3.2 to 4.2 cGy and from 1.2 to 2.2 cGy, respectively. The out-of-field doses to OAR are sensitive to the distance between the treated target and the OAR. For a typical Head-and-Neck IMRT/VMAT treatment the out-of-field doses to eyes are 1–3% of the target dose, or 2–6 cGy per fraction. Conclusion: The imaging doses to OAR are predictable based on the imaging protocols used when OARs are within the imaged volume and can be estimated and accounted for by using tabulated values. The unintended out-of-field doses are proportional to the target dose, strongly depend on the distance between the treated target and OAR, and are generally higher comparing to the imaging dose. This work was partially supported by Varian research grant VUMC40590.

60 APPLIED LIFE SCIENCES↗

Image Fusion Guidance for In Situ Laser Fenestration of Aortic Stent graft for Endovascular Repair of Complex Aortic Aneurysm: Feasibility, Efficacy and Overall Functional Success

Objective: To evaluate feasibility, efficacy and overall functional success of image fusion guidance during laser-assisted in situ fenestration of aortic stent graft (LISFAS) for endovascular repair of complex aortic aneurysm (complex-EVAR) in a prospective study. Methods: Between September 2016 and July 2018, 20 patients were included and treated with LISFAS for complex-EVAR. Aortic aneurysms were either para-renal (n = 15) or thoraco-abdominal (n = 5) with 57 mm [first quartile: 54; third quartile: 68] median aneurysm diameter in 69 years [68;78] patients. All interventions were performed using the same angiographic system and 3D image fusion software for overlying pre-intervention CTA on per-intervention 2D fluoroscopy with cone-beam CT images to display target vessels ostia. Results: LISFAS for complex-EVAR with image fusion was performed in all patients, and no endovascular intervention required conversion to an open aortic repair. LISFAS of all target vessels was feasible in 18 patients (90%); 48 fenestrations out of 50 were performed successfully. Two fenestrations failed for renal arteries in two patients. Median ischemic times were as follows: 34 min [25;43] for superior mesenteric artery; 69 min [56;83] for left renal artery; 73 min [36;102] for right renal artery; and 93 min [89;96] for the celiac trunk. Median intervention and fluoroscopy times, iodinated contrast volume and X-ray exposure were 180 min [150;180], 74 min [64;87], 80 mL [59;113] and 338 Gy.cm{sup 2} [259;495], respectively. Efficacy was found in 17 patients (85%) on one-week follow-up CTA: Two patients had type 1 and 3 endoleaks, respectively, that were successfully embolized. Overall functional success was 90%. Median hospitalization stay was 9 days [8, 17]. The 30-day safety analysis was 90% (n = 2 deaths) owing to an undetermined cause and to bowel ischemia after low flow in intensive care unit. Conclusions: LISFAS using image fusion was feasible, efficient and overall functionally successful for complex-EVAR in this preliminary study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-16A-01: A Novel Method to Estimate Normal Tissue Dose for Radiotherapy Patients to Support Epidemiologic Studies of Second Cancer Risk

Purpose: Patient cohort of second cancer study often involves radiotherapy patients with no radiological images available: We developed methods to construct a realistic surrogate anatomy by using computational human phantoms. We tested this phantom images both in a commercial treatment planning system (Eclipse) and a custom Monte Carlo (MC) transport code. Methods: We used a reference adult male phantom defined by International Commission on Radiological Protection (ICRP). The hybrid phantom which was originally developed in Non-Uniform Rational B-Spline (NURBS) and polygon mesh format was converted into more common medical imaging format. Electron density was calculated from the material composition of the organs and tissues and then converted into DICOM format. The DICOM images were imported into the Eclipse system for treatment planning, and then the resulting DICOM-RT files were imported into the MC code for MC-based dose calculation. Normal tissue doses were calculation in Eclipse and MC code for an illustrative prostate treatment case and compared to each other. Results: DICOM images were generated from the adult male reference phantom. Densities and volumes of selected organs between the original phantom and ones represented within Eclipse showed good agreements, less than 0.6%. Mean dose from Eclipse and MC code match less than 7%, whereas maximum and minimum doses were different up to 45%. Conclusion: The methods established in this study will be useful for the reconstruction of organ dose to support epidemiological studies of second cancer in cancer survivors treated by radiotherapy. We also work on implementing body size-dependent computational phantoms to better represent patient's anatomy when the height and weight of patients are available.

60 APPLIED LIFE SCIENCES↗

SU-C-18A-02: Image-Based Camera Tracking: Towards Registration of Endoscopic Video to CT

Purpose: Endoscopic examinations are routinely performed on head and neck and esophageal cancer patients. However, these images are underutilized for radiation therapy because there is currently no way to register them to a CT of the patient. The purpose of this work is to develop a method to track the motion of an endoscope within a structure using images from standard clinical equipment. This method will be incorporated into a broader endoscopy/CT registration framework. Methods: We developed a software algorithm to track the motion of an endoscope within an arbitrary structure. We computed frame-to-frame rotation and translation of the camera by tracking surface points across the video sequence and utilizing two-camera epipolar geometry. The resulting 3D camera path was used to recover the surrounding structure via triangulation methods. We tested this algorithm on a rigid cylindrical phantom with a pattern spray-painted on the inside. We did not constrain the motion of the endoscope while recording, and we did not constrain our measurements using the known structure of the phantom. Results: Our software algorithm can successfully track the general motion of the endoscope as it moves through the phantom. However, our preliminary data do not show a high degree of accuracy in the triangulation of 3D point locations. More rigorous data will be presented at the annual meeting. Conclusion: Image-based camera tracking is a promising method for endoscopy/CT image registration, and it requires only standard clinical equipment. It is one of two major components needed to achieve endoscopy/CT registration, the second of which is tying the camera path to absolute patient geometry. In addition to this second component, future work will focus on validating our camera tracking algorithm in the presence of clinical imaging features such as patient motion, erratic camera motion, and dynamic scene illumination.

60 APPLIED LIFE SCIENCES↗

SU-E-J-96: Multi-Axis Dose Accumulation of Noninvasive Image-Guided Breast Brachytherapy Through Biomechanical Modeling of Tissue Deformation Using the Finite Element Method

Purpose: Noninvasive image-guided breast brachytherapy delivers conformal HDR Ir-192 brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sites. Given that, commercially-available software for deformable image registration cannot accurately co-register image sets obtained in these two states, a finite element analysis based on a biomechanical model was developed to deform dose distributions for each compression circumstance for dose summation. Methods: The model assumed the breast was under planar stress with values of 30 kPa for Young’s modulus and 0.3 for Poisson’s ratio. Dose distributions from round and skin-dose optimized applicators in cranial-caudal and medial-lateral compressions were deformed using 0.1 cm planar resolution. Dose distributions, skin doses, and dose-volume histograms were generated. Results were examined as a function of breast thickness, applicator size, target size, and offset distance from the center. Results: Over the range of examined thicknesses, target size increased several millimeters as compression thickness decreased. This trend increased with increasing offset distances. Applicator size minimally affected target coverage, until applicator size was less than the compressed target size. In all cases, with an applicator larger or equal to the compressed target size, > 90% of the target covered by > 90% of the prescription dose. In all cases, dose coverage became less uniform as offset distance increased and average dose increased. This effect was more pronounced for smaller target-applicator combinations. Conclusions: The model exhibited skin dose trends that matched MC-generated benchmarking results and clinical measurements within 2% over a similar range of breast thicknesses and target sizes. The model provided quantitative insight on dosimetric treatment variables over a range of clinical circumstances. These findings highlight the need for careful target localization and accurate identification of compression thickness and target offset. Prof. Rivard is a shareholder of Advanced Radiation Therapy, LLC, the manufacturer of the AccuBoost noninvasive image-guided breast brachytherapy system examined herein. None of the other authors have any conflicts-of-interest for this work.

60 APPLIED LIFE SCIENCES↗

SU-F-T-493: An Investigation Into the Feasibility of Using PipsPro Software with Film for Linac QA

Purpose: To determine the feasibility of using radiochromic and radiographic film with Pipspro software for quality assurance of linear accelerators with no on-board imaging. Methods: The linear accelerator being used is a Varian Clinac 21EX. All IGRT is performed using the BrainLab ExacTrac system. Because of the lack of on board imaging, certain monthly and annual TG-142 quality assurance tests are more difficult to perform and analyze to a high degree of accuracy. Pipspro was not designed to be used with hard film, and to our knowledge its use with film had not been investigated. The film used will be GafChromic EBT3 film and Kodak EDR2 film, scanned with an Epson V700 scanner. The following routine tests will be attempted: MLC picket fence, light vs. radiation field coincidence, starshots, and MLC transmission. Results: The only tests that gave accurate and reliable results were the couch, gantry, and collimator starshots. Typical MV and kV images are acquired with a much higher level of contrast between the irradiated and non-irradiated areas when compared to film. Pipspro relies on this level of contrast to be able to automatically detect the fiducial points from its phantom devices, leaf edges for picket fence and transmission tests, and jaw edges for light vs. radiation field tests. Because of this, certain tests gave erroneous results and others were not able to be performed in the software at all, with either type of film. The number of monitor units delivered to the film, the experimental setup, and the scan settings was not able to rectify the problem. Conclusion: For linear accelerators with no on-board imaging, it is not recommended to use hard film with PipsPro to perform TG-142 quality assurance tests. Other software or methods should instead be investigated.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 14: Improving Tissue Segmentation for Monte Carlo Dose Calculation using DECT

Purpose: To improve Monte Carlo dose calculation accuracy through a new tissue segmentation technique with dual energy CT (DECT). Methods: Electron density (ED) and effective atomic number (EAN) can be extracted directly from DECT data with a stoichiometric calibration method. Images are acquired with Monte Carlo CT projections using the user code egs-cbct and reconstructed using an FDK backprojection algorithm. Calibration is performed using projections of a numerical RMI phantom. A weighted parameter algorithm then uses both EAN and ED to assign materials to voxels from DECT simulated images. This new method is compared to a standard tissue characterization from single energy CT (SECT) data using a segmented calibrated Hounsfield unit (HU) to ED curve. Both methods are compared to the reference numerical head phantom. Monte Carlo simulations on uniform phantoms of different tissues using dosxyz-nrc show discrepancies in depth-dose distributions. Results: Both SECT and DECT segmentation methods show similar performance assigning soft tissues. Performance is however improved with DECT in regions with higher density, such as bones, where it assigns materials correctly 8% more often than segmentation with SECT, considering the same set of tissues and simulated clinical CT images, i.e. including noise and reconstruction artifacts. Furthermore, Monte Carlo results indicate that kV photon beam depth-dose distributions can double between two tissues of density higher than muscle. Conclusions: A direct acquisition of ED and the added information of EAN with DECT data improves tissue segmentation and increases the accuracy of Monte Carlo dose calculation in kV photon beams.

07 ISOTOPE AND RADIATION SOURCES↗

Finite element analyses of single particle crushing tests incorporating computed tomography imaging and damage mechanics

Fracture of individual grains within a granular assembly affect the strength and deformation behavior of granular materials under large stress states. Interparticle forces, leading to contact stresses and ultimately fracture initiation, are influenced by particle morphology. A numerical method that incorporates both particle fracture and morphology can provide a more accurate model of a granular material’s macro-scale response. This research investigates an approach to modeling fracture initiation and propagation within individual grains, utilizing high resolution X-ray computed tomography (CT) imaging to consider grain morphology and an explicit finite element code optimized for high performance computing which incorporates damage mechanics. Using precisely measured force-displacement curves from single particle crushing tests of manufactured quartz spheres, the method is validated, and the effects of fracture properties on grain fragmentation are determined. This approach is then used to simulate single particle crushing of Ottawa sand, with grain morphology incorporated through discretized CT images. Here the effect of grain orientation on the force and applied displacement at catastrophic splitting is also explored. The proposed discrete particle based finite element framework can be applied to modeling granular assemblies, considering the effect of individual particle shape and fracture on the assembly’s deformation response through well calibrated numerical simulations.

42 ENGINEERING↗

SU-E-J-30: Benchmark Image-Based TCP Calculation for Evaluation of PTV Margins for Lung SBRT Patients

Purpose: Tumor control probability (TCP) calculated with accumulated radiation doses may help design appropriate treatment margins. Image registration errors, however, may compromise the calculated TCP. The purpose of this study is to develop benchmark CT images to quantify registration-induced errors in the accumulated doses and their corresponding TCP. Methods: 4DCT images were registered from end-inhale (EI) to end-exhale (EE) using a “demons” algorithm. The demons DVFs were corrected by an FEM model to get realistic deformation fields. The FEM DVFs were used to warp the EI images to create the FEM-simulated images. The two images combined with the FEM DVF formed a benchmark model. Maximum intensity projection (MIP) images, created from the EI and simulated images, were used to develop IMRT plans. Two plans with 3 and 5 mm margins were developed for each patient. With these plans, radiation doses were recalculated on the simulated images and warped back to the EI images using the FEM DVFs to get the accumulated doses. The Elastix software was used to register the FEM-simulated images to the EI images. TCPs calculated with the Elastix-accumulated doses were compared with those generated by the FEM to get the TCP error of the Elastix registrations. Results: For six lung patients, the mean Elastix registration error ranged from 0.93 to 1.98 mm. Their relative dose errors in PTV were between 0.28% and 6.8% for 3mm margin plans, and between 0.29% and 6.3% for 5mm-margin plans. As the PTV margin reduced from 5 to 3 mm, the mean TCP error of the Elastix-reconstructed doses increased from 2.0% to 2.9%, and the mean NTCP errors decreased from 1.2% to 1.1%. Conclusion: Patient-specific benchmark images can be used to evaluate the impact of registration errors on the computed TCPs, and may help select appropriate PTV margins for lung SBRT patients.

60 APPLIED LIFE SCIENCES↗

A holey cavity for single-transducer 3D ultrasound imaging with physical optimization

Within the compressive sensing (CS) framework, one effective way to increase the likelihood of successful signal reconstruction is to employ random processes in the construction of the sensing matrix. This work presents a 3D holey cavity, with diverse frequency modes, to spectrally code, that is, randomize, the ultrasound wave fields. The simulated results show that the use of such a cavity enables imaging simple or complex targets, such as spheres or the letter E, by only a single transceiver—something that is not possible without the use of a coding structure like the cavity. The effect of noise on imaging results and the size of the targets on the first-order Born approximation (BA) are also investigated. Moreover, this study attempts to optimize the cavity, based on a single numerical metric, such as the sum of singular values (SSV) or mutual coherence (MC). Yet, it will be shown that neither of these metrics can consistently compare the norm-one imaging performance between two cavities of different materials or hole sizes. This leaves finding a quantitative metric for these kinds of optimizations an open problem.

42 ENGINEERING↗

Optimizing inference of segmentation on high-resolution images in MLExchange

MLExchange is a machine learning (ML) operations platform providing web user-interfaces (UIs) for data visualization and analysis pipelines at synchrotron facilities. Among these UIs is the segmentation app which helps synchrotron users utilize ML algorithms to automatically segment high-resolution scientific images with minimal manual annotation effort. In this work, we share code optimizations that significantly speed up the segmentation inference workflow of large data in short time. By optimizing the sequence of CPU-GPU data transfers and introducing CPU parallelization to key operations, we improve the per-device, per-image frame computational efficiency and observe close to 3×$$\times$$ speedup over the original segmentation inference workflow run time when utilizing a single GPU. Further adaptations enabling multi-GPU inference yield more than 40×$$\times$$ speedup with 100 GPUs compared to the optimized single GPU inference workflow. This acceleration of the segmentation inference workflow will provide MLExchange users with easy access to segmentation results with little wait time.

Lu, Shizhao↗

Effect of image quality on calcification detection in digital mammography

Purpose: This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. Methods: One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. Results: There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from 0.84 to 0.63 and the ROC area decreased from 0.91 to 0.79 (p < 0.0001). This corresponded to a 30% drop in lesion sensitivity at a NLF equal to 0.1. Detection was also sensitive to the dose used. There was no significant difference in detection between the two image processing algorithms used (p > 0.05). It was additionally found that lower threshold gold thickness from CDMAM analysis implied better cluster detection. The measured threshold gold thickness passed the acceptable limit set in the EU standards for all image qualities except half dose CR. However, calcification detection varied significantly between image qualities. This suggests that the current EU guidelines may need revising. Conclusions: Microcalcification detection was found to be sensitive to detector and dose used. Standard measurements of image quality were a good predictor of microcalcification cluster detection.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconstruction of recycling flux from synthetic camera images, evaluated for the Wendelstein 7-X startup limiter

The interpretation of spectroscopic measurements in the edge region of high-temperature plasmas can be guided by modeling with the EMC3-EIRENE code. A versatile synthetic diagnostic module, initially developed for the generation of synthetic camera images, has been extended for the evaluation of the inverse problem in which the observable photon flux is related back to the originating particle flux (recycling). An application of this synthetic diagnostic to the startup phase (inboard) limiter in Wendelstein 7-X (W7-X) is presented, and reconstruction of recycling from synthetic observation of H α emission is evaluated. Here it is shown that recycling—in terms of re-ionization within the view cone of the camera—is underestimated by a factor of about 3 at the peak location and overestimated in between, and that H α emission related to molecular dissociation can locally yield an additional factor of 2 for the ionization to photon conversion. Fitted conversion factors are extracted from the simulation results which include a dependence on the plasma density.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗