Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Design and Development of Modules to Support Live Microscopic Imaging on Ground-Based Microgravity Simulators

In space, astronauts are exposed to environmental stressors that often result in physiological changes. One prominent stressor in spaceflight is microgravity, and research has shown that long term microgravity exposure causes muscle atrophy, bone loss, cardiovascular concerns, and vision impairment. It is critical to understand how altered gravity affects physiology on the cellular, molecular, and gene level in order to accurately assess health risks and to develop effective countermeasures. Ground-based microgravity simulators such as random positioning machines (RPMs) are used to produce some of the biological effects of altered gravity on different cell types and organisms. Real-time imaging during simulations are of particular interest as we can study how basic cell functions such as cell division, cell migration, and proliferation progress under microgravity conditions. However, design limitations of present microgravity simulators such as susceptibility to parasitic vibration and displacement of the sample from the center of rotation challenge the accuracy of experiment results and live images. We have developed a cell culture sample holder module suitable for live microscopic imaging on an RPM. CAD modeling and 3D printing technology were used to implement modifications to the sample holder and to install a digital microscope to perform live bright-field and fluorescent imaging. Vibration damping materials were also investigated to allow for stable imaging while the microgravity simulator was within a cell culture incubator. Novel methods and hardware modifications for improving live cell imaging on ground-based microgravity simulators were proposed and discussed.

3D printing↗

An improved method for simulating microcalcifications in digital mammograms

The assessment of the performance of a digital mammography system requires an observer study with a relatively large number of cases with known truth which is often difficult to assemble. Several investigators have developed methods for generating hybrid abnormal images containing simulated microcalcifications. This article addresses some of the limitations of earlier methods. The new method is based on digital images of needle biopsy specimens. Since the specimens are imaged separately from the breast, the microcalcification attenuation profile scan is deduced without the effects of over and underlying tissues. The resulting templates are normalized for image acquisition specific parameters and reprocessed to simulate microcalcifications appropriate to other imaging systems, with different x-ray, detector and image processing parameters than the original acquisition system. This capability is not shared by previous simulation methods that have relied on extracting microcalcifications from breast images. The method was validated by five experienced mammographers who compared 59 pairs of simulated and real microcalcifications in a two-alternative forced choice task designed to test if they could distinguish the real from the simulated lesions. They also classified the shapes of the microcalcifications according to a standardized clinical lexicon. The observed probability of correct choice was 0.415, 95% confidence interval (0.284, 0.546), showing that the radiologists were unable to distinguish the lesions. The shape classification revealed substantial agreement with the truth (mean kappa=0.70), showing that we were able to accurately simulate the lesion morphology. While currently limited to single microcalcifications, the method is extensible to more complex clusters of microcalcifications and to three-dimensional images. It can be used to objectively assess an imaging technology, especially with respect to its ability to adequately visualize the morphology of the lesions, which is a critical factor in the benign versus malignant classification of a lesion detected in screening mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Extended Catalog of Galaxy–Galaxy Strong Gravitational Lenses Discovered in DES Using Convolutional Neural Networks

We search Dark Energy Survey (DES) Year 3 imaging for galaxy–galaxy strong gravitational lenses using convolutional neural networks, extending previous work with new training sets and covering a wider range of redshifts and colors. We train two neural networks using images of simulated lenses, then use them to score postage-stamp images of 7.9 million sources from DES chosen to have plausible lens colors based on simulations. We examine 1175 of the highest-scored candidates and identify 152 probable or definite lenses. Examining an additional 20,000 images with lower scores, we identify a further 247 probable or definite candidates. After including 86 candidates discovered in earlier searches using neural networks and 26 candidates discovered through visual inspection of blue-near-red objects in the DES catalog, we present a catalog of 511 lens candidates.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy Minimization of Molecular Features Observed on the (110) Face of Lysozyme Crystals

Molecular dynamics and energy minimization have been carried out using the program XPLOR to check the plausibility of a model lysozyme crystal surface. The molecular features of the (110) face of lysozyme were observed using atomic force microscopy (AFM). A model of the crystal surface was constructed using the PDB file 193L, and was used to simulate an AFM image. Molecule translations, van der Waals radii, and assumed AFM tip shape were adjusted to maximize the correlation coefficient between the experimental and simulated images. The highest degree of 0 correlation (0.92) was obtained with the molecules displaced over 6 A from their positions within the bulk of the crystal. The quality of this starting model, the extent of energy minimization, and the correlation coefficient between the final model and the experimental data will be discussed.

Perozzo, Mary A.↗

Model-based cartilage thickness measurement in the submillimeter range

Current methods of image-based thickness measurement in thin sheet structures utilize second derivative zero crossings to locate the layer boundaries. It is generally acknowledged that the nonzero width of the point spread function (PSF) limits the accuracy of this measurement procedure. We propose a model-based method that strongly reduces PSF-induced bias by incorporating the PSF into the thickness estimation method. We estimated the bias in thickness measurements in simulated thin sheet images as obtained from second derivative zero crossings. To gain insight into the range of sheet thickness where our method is expected to yield improved results, sheet thickness was varied between 0.15 and 1.2 mm with an assumed PSF as present in the high-resolution modes of current computed tomography (CT) scanners [full width at half maximum (FWHM) 0.5-0.8 mm]. Our model-based method was evaluated in practice by measuring layer thickness from CT images of a phantom mimicking two parallel cartilage layers in an arthrography procedure. CT arthrography images of cadaver wrists were also evaluated, and thickness estimates were compared to those obtained from high-resolution anatomical sections that served as a reference. The thickness estimates from the simulated images reveal that the method based on second derivative zero crossings shows considerable bias for layers in the submillimeter range. This bias is negligible for sheet thickness larger than 1 mm, where the size of the sheet is more than twice the FWHM of the PSF but can be as large as 0.2 mm for a 0.5 mm sheet. The results of the phantom experiments show that the bias is effectively reduced by our method. The deviations from the true thickness, due to random fluctuations induced by quantum noise in the CT images, are of the order of 3% for a standard wrist imaging protocol. In the wrist the submillimeter thickness estimates from the CT arthrography images correspond within 10% to those estimated from the anatomical sections. We present a method that yields virtually unbiased thickness estimates of cartilage layers in the submillimeter range. The good agreement of thickness estimates from CT images with estimates from anatomical sections is promising for clinical application of the method in cartilage integrity staging of the wrist and the ankle.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End–to–End Metasurface Design for Temperature Imaging via Broadband Planck‐Radiation Regression

A theoretical framework is presented for temperature imaging from long-wavelength infrared (LWIR) thermal radiation (e.g., 8–12 µm) through the end-to-end design of a metasurface-optics frontend and a computational-reconstruction backend. A new nonlinear reconstruction algorithm, “Planck regression”, is introduced to reconstruct the temperature map from a gray scale sensor image, even in the presence of severe chromatic aberration, by exploiting black body and optical physics particular to thermal imaging. This algorithm is combined with an end-to-end approach that optimizes manufacturable, single-layer metasurfaces to yield the most accurate reconstruction. The designs demonstrate high-quality, noise-robust reconstructions of arbitrary temperature maps (including completely random images) in simulations of an ultra-compact thermal-imaging device. Here, it is also shown that Planck regression is much more generalizable to arbitrary images than a straightforward neural-network reconstruction, which requires a large training set of domain-specific images.

36 MATERIALS SCIENCE↗

Micro-CT Imaging and Fluid Flow Simulations of Fractures in MSEEL Shale

micro-CT scans of a naturally fractured MSEEL shale sample as a shear fracture is generated and displaced in the center, intact region of the sample. Steady State laminar fluid flow simulations were then performed on each individual fracture during each experimental segment as effective stress and shear displacement changed. Released under LA-UR-21-24335.

Fractures,Fracturing Initiation,Marcellus Shale↗

Remote detection of geobotanical anomalies associated with hydrocarbon microseepage using thematic mapper simulator (TMS) and airborne imaging spectrometer (AIS) data

An interpretation of TMS and AIS data sets collected from Lost River, West Virginia, are presented, along with a brief review of the supervised vegetation classification approach to vegetation mapping used at Lost River. A preliminary study of AIS data suggests that contiguous high-spectral resolution data from a very limited portion of the spectrum (1.2-1.5 micron) provide a greater discriminatory capability than do broad-band sensors such as the TMS covering of wider spectral range (0.45-2.35 microns).

Rock, B. N.↗

Data simulation for the Lightning Imaging Sensor (LIS)

This project aims to build a data analysis system that will utilize existing video tape scenes of lightning as viewed from space. The resultant data will be used for the design and development of the Lightning Imaging Sensor (LIS) software and algorithm analysis. The desire for statistically significant metrics implies that a large data set needs to be analyzed. Before 1990 the quality and quantity of video was insufficient to build a usable data set. At this point in time, there is usable data from missions STS-34, STS-32, STS-31, STS-41, STS-37, and STS-39. During the summer of 1990, a manual analysis system was developed to demonstrate that the video analysis is feasible and to identify techniques to deduce information that was not directly available. Because the closed circuit television system used on the space shuttle was intended for documentary TV, the current value of the camera focal length and pointing orientation, which are needed for photoanalysis, are not included in the system data. A large effort was needed to discover ancillary data sources as well as develop indirect methods to estimate the necessary parameters. Any data system coping with full motion video faces an enormous bottleneck produced by the large data production rate and the need to move and store the digitized images. The manual system bypassed the video digitizing bottleneck by using a genlock to superimpose pixel coordinates on full motion video. Because the data set had to be obtained point by point by a human operating a computer mouse, the data output rate was small. The loan and subsequent acquisition of a Abekas digital frame store with a real time digitizer moved the bottleneck from data acquisition to a problem of data transfer and storage. The semi-automated analysis procedure was developed using existing equipment and is described. A fully automated system is described in the hope that the components may come on the market at reasonable prices in the next few years.

Boeck, William L.↗

Simulation of TRMM Microwave Imager Brightness Temperature using Precipitation Radar Reflectivity for Convective and Stratiform Rain Areas over Land

Rain is highly variable in space and time. In order to measure rainfall over global land with satellites, we need observations with very high spatial resolution and frequency in time. On board the Tropical Rainfall Measuring Mission (TRMM) satellite, the Precipitation Radar (PR) and Microwave Imager (TMI) are flown together for the purpose of estimating rain rate. The basic method to estimate rain from PR has been developed over the past several decades. On the other hand, the TMI method of rain estimation is still in the state development, particularly over land. The objective of this technical memorandum is to develop a theoretical framework that helps relate the observations made by these two instruments. The principle result of this study is that in order to match the PR observations with the TMI observations in convective rain areas, a mixed layer of graupel and supercooled water drops above the freezing level is needed. On the other hand, to match these observations in the stratiform region, a layer of snowflakes with appropriate densities above the freezing level, and a melting layer below the freezing level, are needed. This understanding can lead to a robust rainfall estimation technique from the microwave radiometer observations.

Prabhakara, C.↗