Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

Gamma-Ray Focusing Optics for Small Animal Imaging

There is a well-established need for high-resolution radionuclide imaging techniques that provide non-invasive measurement of physiological function in small animals. We, therefore, have begun developing a small animal radionuclide imaging system using grazing incidence mirrors to focus low-energy gamma-rays emitted by I-125, and other radionuclides. Our initial prototype optic, fabricated from thermally-formed glass, demonstrated a resolution of 1500 microns, consistent with the performance predicted by detailed simulations. More recently, we have begun constructing mirrors using a replication technique that reduces low spatial frequency errors in the mirror surface, greatly improving the resolution. Each technique offers particular advantages: e.g., multilayer coatings are easily deposited on glass, while superior resolution is possible with replicated optics. Scaling the results from our prototype optics, which only have a few nested shells, to system where the lens has a full complement of several tens of nested shells, a sensitivity of approx. 1 cps/micro Ci is possible, with the exact number dependent on system magnification and radionuclide species. (Higher levels of efficiency can be obtained with multi-optic imaging systems.) The gamma-ray lens will achieve a resolution as good as 100 microns, independent of the final sensitivity. The combination of high spatial resolution and modest sensitivity will enable in vivo single photon emission imaging studies in small animals.

Pivovaroff, M. J.↗

Advanced Real-Time Optical Imaging: Part I

Materials research is significantly assisted by information gathered from imaging. Images may be macroscopic or microscopic; different imaging techniques ranging from conventional microscopes to synchrotron tomography are selected for various research purposes and goals. While most materials imaging is performed in static environments at room temperature because of its appropriateness (or due to device limitations), simple optical imaging may transform into a powerful tool if it is dynamically captured during materials treatments, processing, or physical/chemical exposures. Real-time observations this way provide researchers with vital information on materials behaviors under controlled but various conditions. In the field of energy materials, it is not uncommon to require materials studies under high-temperature, high-pressure, and/or corrosive conditions. In gasifiers, for example, investigations of sensor alloy degradation, slag-refractory reactions, and coal agglomeration require samples to undergo severe environments where direct imaging would be difficult using conventional experimental methods. Finally, while post mortem analysis often provides critical information, interpretation may sometimes be complicated without confirming such occurrences under those conditions.

36 MATERIALS SCIENCE↗

MRI of Acute Abdominal and Pelvic Non-obstetric Conditions in Pregnancy

Purpose of Review: The evaluation of abdominal and pelvic pain in the pregnant patient presents unique challenges due to altered physiology and implications of radiation exposure on the fetus. In many instances, a radiologist must consider the potential risk of fetal injury from ionizing radiation and maintaining diagnostic quality imaging. This article will focus on the role of MR imaging and its applications in a variety of acute abdomen and pelvic non-obstetric conditions potentially affecting the pregnant patient. Recent Findings: Non-contrast MR imaging is routinely employed in the presence of an initial equivocal ultrasound. However, MR is playing an increasingly more important role in the imaging of the pregnant patient, potentially surpassing the utility of conventional imaging techniques. Summary: As radiologists become more comfortable interpretating abdominal and pelvic MRI, MR will play a bigger role in imaging the pregnant patient in the emergency room, in the years to come.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlative single-cell hard X-ray computed tomography and X-ray fluorescence imaging

Abstract X-ray computed tomography (XCT) and X-ray fluorescence (XRF) imaging are two non-invasive imaging techniques to study cellular structures and chemical element distributions, respectively. However, correlative X-ray computed tomography and fluorescence imaging for the same cell have yet to be routinely realized due to challenges in sample preparation and X-ray radiation damage. Here we report an integrated experimental and computational workflow for achieving correlative multi-modality X-ray imaging of a single cell. The method consists of the preparation of radiation-resistant single-cell samples using live-cell imaging-assisted chemical fixation and freeze-drying procedures, targeting and labeling cells for correlative XCT and XRF measurement, and computational reconstruction of the correlative and multi-modality images. With XCT, cellular structures including the overall structure and intracellular organelles are visualized, while XRF imaging reveals the distribution of multiple chemical elements within the same cell. Our correlative method demonstrates the feasibility and broad applicability of using X-rays to understand cellular structures and the roles of chemical elements and related proteins in signaling and other biological processes.

59 BASIC BIOLOGICAL SCIENCES↗

Development of electron source feedback for enhanced X-ray beam stability at NSLS-II

Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.

36 MATERIALS SCIENCE↗

Correlations of Cu(In, Ga)Se2 Imaging with Device Performance, Defects, and Microstructural Properties

Camera imaging techniques have been used for the characterization of Cu(In,Ga)Se{sub 2} (CIGS) solar cells. Photoluminescence (PL) imaging shows brightness variations after the deposition of the CIGS layer that persist through CdS deposition and subsequent processing steps to finish the devices. PL and electroluminescence imaging on finished cells show a correlation to the devices corresponding efficiency and open-circuit voltage (V{sub OC}), and dark defect-related spots correspond to bright spots on images from illuminated lock-in thermography (LIT) and forward-bias dark LIT. These image-detected defect areas are weak diodes and shunts. Imaging provides locations of defects detrimental to solar cell performance. Some of these defects are analyzed in more detail by scanning electron microscopy using cross-sectional views.

14 SOLAR ENERGY↗

Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved landmark-only registration provided the noise in the surface points is not excessively high. Increased variability on the landmark fiducials resulted in increased registration errors; however, refinement of the initial landmark registration by the surface-based algorithm can compensate for small initial misalignments. The surface-based registration algorithm is quite robust to noise on the surface points and continues to improve landmark registration even at high levels of noise on the surface points. Both the canine and patient studies also demonstrate that combined landmark and surface registration has lower errors than landmark registration alone. Conclusions: In this work, we describe a model for evaluating the impact of noise variability on the input parameters of a registration algorithm in the context of cardiac ablation therapy. The model can be used to predict both registration error as well as assess which inputs have the largest effect on registration accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-18C-03: Evaluation of Deformable Image Registration for Lung Motion Estimation Using Hyperpolarized Gas Tagging MRI

Purpose: Hyperpolarized gas (HP) tagging MRI is a novel imaging technique for direct measurement of lung motion during breathing. This study aims to quantitatively evaluate the accuracy of deformable image registration (DIR) in lung motion estimation using HP tagging MRI as references. Methods: Three healthy subjects were imaged using the HP MR tagging, as well as a high-resolution 3D proton MR sequence (TrueFISP) at the end-of-inhalation (EOI) and the end-of-exhalation (EOE). Ground truth of lung motion and corresponding displacement vector field (tDVF) was derived from HP tagging MRI by manually tracking the displacement of tagging grids between EOI and EOE. Seven different DIR methods were applied to the high-resolution TrueFISP MR images (EOI and EOE) to generate the DIR-based DVFs (dDVF). The DIR methods include Velocity (VEL), MIM, Mirada, multi-grid B-spline from Elastix (MGB) and 3 other algorithms from DIRART toolbox (Double Force Demons (DFD), Improved Lucas-Kanade (ILK), and Iterative Optical Flow (IOF)). All registrations were performed by independent experts. Target registration error (TRE) was calculated as tDVF – dDVF. Analysis was performed for the entire lungs, and separately for the upper and lower lungs. Results: Significant differences between tDVF and dDVF were observed. Besides the DFD and IOF algorithms, all other dDVFs showed similarity in deformation magnitude distribution but away from the ground truth. The average TRE for entire lung ranged 2.5−23.7mm (mean=8.8mm), depending on the DIR method and subject's breathing amplitude. Larger TRE (13.3–23.7mm) was found in subject with larger breathing amplitude of 45.6mm. TRE was greater in lower lung (2.5−33.9 mm, mean=12.4mm) than that in upper lung (2.5−11.9 mm, mean=5.8mm). Conclusion: Significant differences were observed in lung motion estimation between the HP gas tagging MRI method and the DIR methods, especially when lung motion is large. Large variation among different DIR methods was also observed.

60 APPLIED LIFE SCIENCES↗

NASA/ASEE Summer Faculty Fellowship Program, 1990, Volume 1

The 1990 Johnson Space Center (JSC) NASA/American Society for Engineering Education (ASEE) Summer Faculty Fellowship Program was conducted by the University of Houston-University Park and JSC. A compilation of the final reports on the research projects are presented. The topics covered include: the Space Station; the Space Shuttle; exobiology; cell biology; culture techniques; control systems design; laser induced fluorescence; spacecraft reliability analysis; reduced gravity; biotechnology; microgravity applications; regenerative life support systems; imaging techniques; cardiovascular system; physiological effects; extravehicular mobility units; mathematical models; bioreactors; computerized simulation; microgravity simulation; and dynamic structural analysis.

Bannerot, Richard B.↗

Carbon Fiber Strand Tensile Failure Dynamic Event Characterization

There are few if any clear, visual, and detailed images of carbon fiber strand failures under tension useful for determining mechanisms, sequences of events, different types of failure modes, etc. available to researchers. This makes discussion of physics of failure difficult. It was also desired to find out whether the test article-to-test rig interface (grip) played a part in some failures. These failures have nothing to do with stress rupture failure, thus representing a source of waste for the larger 13-00912 investigation into that specific failure type. Being able to identify or mitigate any competing failure modes would improve the value of the 13-00912 test data. The beginnings of the solution to these problems lay in obtaining images of strand failures useful for understanding physics of failure and the events leading up to failure. Necessary steps include identifying imaging techniques that result in useful data, using those techniques to home in on where in a strand and when in the sequence of events one should obtain imaging data.

Johnson, Kenneth L.↗

Quality Characterization of Silicon Bricks using Photoluminescence Imaging and Photoconductive Decay: Preprint

Imaging techniques can be applied to multicrystalline silicon solar cells throughout the production process, which includes as early as when the bricks are cut from the cast ingot. Photoluminescence (PL) imaging of the band-to-band radiative recombination is used to characterize silicon quality and defects regions within the brick. PL images of the brick surfaces are compared to minority-carrierlifetimes measured by resonant-coupled photoconductive decay (RCPCD). Photoluminescence images on silicon bricks can be correlated to lifetime measured by photoconductive decay and could be used for high-resolution characterization of material before wafers are cut. The RCPCD technique has shown the longest lifetimes of any of the lifetime measurement techniques we have applied to the bricks.RCPCD benefits from the low-frequency and long-excitation wavelengths used. In addition, RCPCD is a transient technique that directly monitors the decay rate of photoconductivity and does not rely on models or calculations for lifetime. The measured lifetimes over brick surfaces have shown strong correlations to the PL image intensities; therefore, this correlation could then be used totransform the PL image into a high-resolution lifetime map.

14 SOLAR ENERGY↗

Initial results and designs of dual-filter and plenoptic imaging for high-temperature plasmas

Mass injection has found new applications in magnetic fusion including edge-localized-mode control. Better understanding of injected-mass-plasma interactions requires spatially and temporally resolved diagnostics that can characterize the dynamics of the mass interactions with plasmas. Fast imaging can be used to characterize the ionization dynamics such as the propagation of the ionization front, which moves at the thermal sound or higher speed, and mixing of the neutral atoms with the ambient plasma. Multi-wavelength spectral imaging is promising since different parts of the plasma give different spectral signatures. Here in this paper we describe a dual-spectral imaging technique based on a monochromatic camera sensor and filters with two passing optical wavelengths. The method is shown to improve image contrast, and it compares favorably with alternatives such as color cameras and methods using a filter wheel. Further improvements through relative filter area ratios and plenoptic imaging are possible. Finally, the initial results from EAST and plenoptic imaging are also included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing nanoparticle substrate interactions with synchrotron infrared nanospectroscopy: Coupling gold nanorod Fabry-Pérot resonances with SiO 2 and $h$-BN phonons

Spectroscopic interrogation of materials in the midinfrared with nanometer spatial resolution is inherently difficult due to the long wavelengths involved, reduced detector efficiencies, and limited availability of spectrally bright, coherent light sources. Technological advances are driving techniques that overcome these challenges, enabling material characterization in this relatively unexplored spectral regime. Synchrotron infrared nanospectroscopy (SINS) is an imaging technique that provides local sample information of nanoscale target specimens in an experimental energy window between 330 and 5000 cm -1 . Here, using SINS, we analyzed a series of individual gold nanorods patterned on a SiO 2 substrate and on a flake of hexagonal boron nitride. The SINS spectra reveal interactions between the nanorod photonic Fabry-Pérot resonances and the surface phonon polaritons of each substrate, which are characterized as avoided crossings. A coupled oscillator model of the hybrid system provides a deeper understanding of the coupling and provides a theoretical framework for future exploration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tailored approach to study Legionella infection using a lattice light sheet microscope (LLSM)

Legionella is a genus of ubiquitous environmental pathogens found in freshwater systems, moist soil, and composted materials. More than four decades of Legionella research has provided important insights into Legionella pathogenesis. Although standard commercial microscopes have led to significant advances in understanding Legionella pathogenesis, great potential exists in the deployment of more advanced imaging techniques to provide additional insights. The lattice light sheet microscope (LLSM) is a recently developed microscope for 4D live cell imaging with high resolution and minimum photo-damage. We built a LLSM with an improved version for the optical layout with two path-stretching mirror sets and a novel reconfigurable galvanometer scanner ( RGS ) module to improve the reproducibility and reliability of the alignment and maintenance of the LLSM. We commissioned this LLSM to study Legionella pneumophila infection with a tailored workflow designed over instrumentation, experiments, and data processing methods. Our results indicate that Legionella pneumophila infection is correlated with a series of morphological signatures such as smoothness, migration pattern and polarity both statistically and dynamically. Our work demonstrates the benefits of using LLSM for studying long-term questions in bacterial infection. Our free-for-use modifications and workflow designs on the use of LLSM system contributes to the adoption and promotion of the state-of-the-art LLSM technology for both academic and commercial applications.

59 BASIC BIOLOGICAL SCIENCES↗

Kelvin Probe Force Microscopy for High-Resolution Imaging of Hydrogen in Steel and Aluminum Alloys (Q3 Progress Report)

SRNL is working with Sandia NL, Pacific Northwest NL and Oak Ridge NL in the H-Mat consortium with the objective of developing materials with a higher resistance to hydrogen attack. Understanding the mechanism of hydrogen interactions in metal alloys is continually a topic of interest for applications which involve the long-term storage of hydrogen. Atomic hydrogen segregates to regions of extended defects, such as grain and phase boundaries, and can cause stress and premature cracking through a process known as hydrogen embrittlement. Advanced microstructural imaging techniques, with minimal sample preparation needs, that are capable of resolving hydrogen segregation at the nanometer scale is needed. Current imaging technologies to aid in understanding the effects of hydrogen in metals involve primarily fractography after mechanical testing. Hydrogen segregated at the surface and particularly at surface defect sites changes the local work function of the material. This can be measured by Kelvin Probe Force Microscopy, KPFM, a variant of atomic force microscopy (AFM). KPFM produces surface potential images and is capable of measuring the local change in work function of surfaces with very high spatial resolution. The spatial resolution of KPFM is optimally ~5 nm, yielding very high hydrogen concentration/microstructure coloration capabilities. By locating the presence of hydrogen and its relationship with extended defects, it may be possible to develop microstructures less susceptible to hydrogen embrittlement. The objective of this effort is to assess the utility of KPFM to determine the H 2 concentration profiles surrounding complex microstructural features in high strength steel and aluminum alloys subjected to high pressure hydrogen exposure.

08 HYDROGEN↗

Kelvin Probe Force Microscopy for High-Resolution Imaging of Hydrogen in Steel and Aluminum Alloys

SRNL is working with Sandia NL, Pacific Northwest NL and Oak Ridge NL in the H-Mat consortium with the objective of developing materials with a higher resistance to hydrogen attack. Understanding the mechanism of hydrogen interactions in metal alloys is continually a topic of interest for applications which involve the long-term storage of hydrogen. Atomic hydrogen segregates to regions of extended defects, such as grain and phase boundaries, and can cause stress and premature cracking through a process known as hydrogen embrittlement. Advanced microstructural imaging techniques, with minimal sample preparation needs, that are capable of resolving hydrogen segregation at the nanometer scale is needed. Current imaging technologies to aid in understanding the effects of hydrogen in metals involve primarily fractography after mechanical testing. Hydrogen segregated at the surface and particularly at surface defect sites changes the local work function of the material. This can be measured by Kelvin Probe Force Microscopy, KPFM, a variant of atomic force microscopy (AFM). KPFM produces surface potential images and is capable of measuring the local change in work function of surfaces with very high spatial resolution. The spatial resolution of KPFM is optimally ~5 nm, yielding very high hydrogen concentration/microstructure coloration capabilities. By locating the presence of hydrogen and its relationship with extended defects, it may be possible to develop microstructures less susceptible to hydrogen embrittlement. The objective of this effort is to assess the utility of KPFM to determine the H 2 concentration profiles surrounding complex microstructural features in high strength steel and aluminum alloys subjected to high pressure hydrogen exposure.

08 HYDROGEN↗

The application of infrared speckle interferometry to the imaging of remote galaxies and AGN

A 1.5 meter reflector, used for both infrared and optical astronomy, is also being used for infrared speckle interferometry and CCD imaging. The application of these imaging techniques to remote galaxies and active galactic nuclei are discussed. A simple model for the origin of speckle in coherent imaging systems is presented. Very careful photometry of the continuum of the galaxy M31 is underway using CCD images. It involves extremely intensive data reduction because the object itself is very large and has low surface brightness.

Olivares, Robert O.↗