Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inlet diffusers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Computational framework for modeling membrane processes without process and solution property simplifications

Accurately modeling membrane processes is critical to evaluating novel process configurations, designing scalable membrane systems, informing process cost estimates, and directing future research. Most membrane process models trade accuracy for computational efficiency by employing simplified approximations of the process (i.e. no salt flux, no pressure drop) and solution properties (i.e. ideal solution, and constant density, viscosity, and diffusivity). Our report introduces a detailed one-dimensional finite difference model for evaluating membrane processes that avoids these common simplifications. We apply this model to quantify the error introduced by these simplifications for case studies of reverse osmosis, osmotically assisted reverse osmosis, forward osmosis, and pressure retarded osmosis. While the magnitude of error introduced by these simplifications is reliant on the case study parameters and specifications, we find that existing model formulations can underestimate or overestimate average water flux by nearly 50% for some membrane processes operating under standard conditions. Lastly we investigate the error introduced by simplified inlet-outlet models that do not solve the governing system of differential equations, and we assess the accuracy of novel inlet-outlet formulations that use a log and geometric mean, instead of the typical arithmetic mean, to represent non-linear water flux profiles.

42 ENGINEERING↗

Flame propagation under partially-premixed conditions

This study concentrates on developing a better understanding of triple flames. We relax the assumption of zero heat release, address the issue of stabilization, and, in order to investigate the role that heat release plays in flame propagation in partially premixed combustion, we return to a simple flow field and investigate the behavior of flames in a laminar environment. We solve the compressible Navier-Stokes equations in a two-dimensional domain. At the boundaries, we use an inflow boundary condition on the left and nearly-perfect reflective boundary conditions, required to avoid pressure drift, at the outflow and sides. After the flow and flame are initialized, the mixture fraction is varied at the inlet from its uniform stoichiometric value to a tanh profile varying from zero to one. As the mixture fraction gradient reaches the flame surface only the centerline is exposed to the stoichionetric mixture fraction and locally maintains the planar flame speed and reaction rate. Above this point the mixture is fuel rich, and below fuel lean. As a result, these regions of non-unity equivalence ratio burn less, the reaction rate drops, and the local flame speed is reduced. The excess fuel and oxidizer then combine behind the premixed flame along the stoichiometric surface and burn in a trailing diffusion flame. Thus the 'triple' flame refers to the fuel-rich premixed flame, the fuel-lean premixed flame, and the trailing diffusion flame. Due to heat release, the normal velocity across the flame is increased, whereas the tangential component remains unchanged. Far-field flame speed, local flame speed, and their differences are shown as a function of the local mixing thickness. It was also determined that the lateral position of the flame affects stabilization, and the distribution of the reaction rate along the premixed wings of triple flames affects flame propagation.

Ruetsch, Gregory R.↗

Combined Experimental and Modeling Study of the Interactions of Acid Gas with Common Spacecraft Surfaces for Fire Safety Applications

A fire in a spacecraft poses detrimental consequences and risks mission success in addition to crew safety. This is compounded during long-duration missions when the crew has limited options to recover from a fire. A common spacecraft fire concern is the smoldering of wire insulation, typically made from Polyvinyl chloride (PVC) or Polytetrafluoroethylene (PTFE). This creates acid gases such as Hydrogen Chloride (HCl), Hydrogen Fluoride (HF) and Hydrogen Cyanide (HCN). These poisonous gases are hazardous to the crew. They also interact with common surfaces within the spacecraft more than dominant combustion products such as CO2 and H2O. This makes them more difficult to track for potential fire detection techniques, or for postfire clean-up. It is imperative to be able to understand and predict the fate of these poisonous species in a microgravity environment in order to design a safe vehicle. HCl interacts with a number of materials inside a spacecraft. Primary among these materials is aluminum, which is abundantly used due to its strong and light weight nature. Aluminum has a natural oxide layer that protects it from corrosion but is typically treated to enhance this oxide layer. Among these treatments is a chromate conversion coating (CCC), which provides a thin enough protective oxide layer to still conduct electricity, and a traditional anodized material that has a thicker oxide layer that does not conduct electricity. Nomex is another common material found inside a spacecraft. It is a flame-resistant woven polymer that is related to nylon. This commercially available material is used for cargo storage bags and as a fire barrier. Physics-based models were developed to predict the uptake of HCl by these materials. The ultimate objective of these models is to predict the fate of HCl within the spacecraft so that sensors can be placed in meaningful locations in future missions based on the model predictions. To support these modeling efforts, experiments were performed in a cast acrylic test cell that measured the difference between the inlet and outlet concentration of HCl after inserting a sample rod of the test material. Different uptake capacities were realized for each type of sample tested. A computational fluid dynamics model (CFD) model of the reactor was then constructed that used a one-step global reaction rate with calibratable reaction (or kinetic) constants. These constants were calibrated to match the HCl uptake on the CCC aluminum samples, and the same kinetic constants were then tested for the stock and anodized aluminum samples. Model predictions matched the experimental data for the stock aluminum, and to a much lesser extent, the anodized aluminum. The model was additionally validated at different flow rates, sample surface areas, and inlet concentrations, and showed good agreement for all stock and CCC samples. The model did not accurately predict the HCl uptake in the anodized samples compared to the other two types of aluminum. Adjusting the kinetic constants and transport properties did little to improve the prediction. X-Ray Photoelectron Spectroscopy (XPS) was used to determine that the oxide layer thickness of anodized aluminum is approximately 5,000 nm, compared to 250 nm for CCC and 50 nm for stock. XPS also revealed presence of chlorine further down in the aluminum oxide layer in anodized samples than CCC and stock samples after the samples were saturated with HCl, indicating that accounting for diffusion of HCl into the oxide layer is important for accurate prediction of HCl uptake onto anodized aluminum. Consequently, a multi-scale model was developed and tested. First, a single pore inside the anodized aluminum oxide layer was modeled and is referred to as the pore-scale model. In this model, HCl diffused through the pore and reacted with the aluminum oxide pore wall to create aluminum chloride. The sample was then saturated when the mass transfer resistance through the growing aluminum chloride layer became too large for the HCl to reach the aluminum oxide wall and continue the reaction. This pore-scale model was coupled to the reactor-scale model using a concentration-dependent diffusion coefficient, resulting in much more accurate predictions (approximately half the sum square error of the aforementioned reactor-scale model that produced good agreement for stock and CCC) for a variety of operating conditions. The amount of water vapor or relative humidity (RH) in the flow during a reactor experiment was determined to influence HCl uptake. Experiments were performed to understand the interaction of gaseous HCl with aluminum surfaces in the presence of water vapor. The results show that increasing levels of RH increased the capacity of aluminum to adsorb HCl but decreased the capacity of Nomex to uptake HCl. A series of tests were performed on individual aluminum samples after they had been saturated with a fixed concentration of HCl in dry air conditions with the goal of determining how their HCl uptake capacity changes after various treatments with water relative to the original saturation tests. HCl-saturated aluminum samples subjected to a second dry air flow at the same HCl concentration as the original test had an uptake of 23.5% of the original sample with no treatment in between. Saturated aluminum samples subjected to an air flow with a RH of 90% in between tests had an uptake of 35.6% of the original. Saturated aluminum samples submerged in distilled water for 12 hours in between tests had an uptake of 82.2% of the original sample. Previously saturated aluminum tested with HCl and a 50% RH air flow resulted in similar uptake characteristics in multiple repeated tests. The experiments show the profound effect water vapor has on HCl uptake onto aluminum surfaces. In the samples subjected to water vapor or liquid water, capillary condensation and capillary diffusion alters the transport of HCl significantly. A model was proposed that developed a relationship between RH and the coefficient of HCl diffusion in aluminum chloride. This produced an “S-shaped” curve with diffusion coefficient as a function of RH, with 45% RH represented as the point where the diffusion coefficient is halfway between no water saturation and 100% water saturation in the aluminum chloride product layer. No difference in uptake characteristics for the experiment or model were realized between 50% and 62% RH. The results from the large-scale microgravity experiment, Saffire, are discussed as they pertain to the fate of HCl throughout a spacecraft. HCl was released, both as a standalone event, and in concurrence with the burning of a structured cloth. These events only produced a small response in the far field HCl sensor, while a PMMA burn that did not produce HCl had a significantly greater response. A ground-based large-scale facility was constructed to flow acid gas at the scale and configuration realized in the Saffire experiments. A CFD model of this duct was constructed to test kinetic parameters developed in this work at a larger scale and different geometric configuration and to predict the results of the large-scale facility. The models developed in this work were used to interpret the results of the microgravity tests and lead the discussion on what further experiments and models are needed in order to predict the fate of acid gas in a spacecraft environment. To summarize, the major contributions of this work are as follows: the capacity to uptake HCl, with and without the presence of water vapor, was measured for a variety of real spacecraft surfaces. Several different models (single reactor-scale, multiscale, spacecraft-scale) were developed and with the aid of modeling, the rate of uptake for those surfaces was also predicted and validated. The kinetic parameters determined from the small-scale reactor experiments and models were used to predict large-scale and microgravity tests. Conclusions from this research will be used in the design of spacecraft vehicles and large-scale microgravity fire safety experiments. The models built by this work will aid designers in sensor placement and could be used to predict acid gas transport from fires in partial gravity, as would be seen in Lunar and Martian habitats.

fire safety↗

Pore‐Scale Modeling of Reactive Transport with Coupled Mineral Dissolution and Precipitation

Abstract We present a new pore‐scale model for multicomponent advective‐diffusive transport with coupled mineral dissolution and precipitation. Both dissolution and precipitation are captured simultaneously by introducing a phase transformation vector field representing the direction and magnitude of the overall phase change. An effective viscosity model is adopted in simulating fluid flow during mineral dissolution‐precipitation that can accurately capture the velocity field without introducing any empirical parameters. The proposed approach is validated against analytical solutions and interface tracking simulations in simplified structures. After validation, the proposed approach is employed in modeling realistic rocks where mineral dissolution and precipitation are dominant at different locations. We have identified three regimes for mineral dissolution‐precipitation coupling: (a) compact dissolution‐precipitation where dissolution is dominant near the inlet and precipitation is dominant near the outlet, (b) wormhole dissolution with clustered precipitation where dissolution generates wormholes in the main flow paths and precipitation clogs the secondary flow paths, and (c) dissolution dominant where all solid grains are gradually dissolved. In the three regimes, the proposed approach provides reliable porosity‐permeability relationships that cannot be described well by traditional macroscale models. We find that the permeability can increase while the overall porosity decreases when the main flow paths are expanded by dissolution and adjacent pore spaces are clogged by precipitation.

58 GEOSCIENCES↗

Synthesis and Characterization of Mixed-Conducting Corrosion Resistant Oxide Supports

An extensive search and evaluation of electrochemically stable catalyst supports (including metal oxides like RuO2-SiO2, RuO2-TiO2, and ITO was perfomed during the 4 years of the project. The suports were also catalyzed by deposition of Pt and tested for its performance and electrochemical stability in RDE and fuel cell experiments. For testing the electrochemical stability and fuel cell performance of the catalysts and supports, we have employed the protocols in use at the Department of Energy and Nissan Technological Center North America (NTCNA). The use of such procedures allows a precise and reproducible estimation of the performance and stability of the materials and permits comparisons among laboratories and DOE funded projects. RuO2-SiO2 catalyst supports showed no loss in surface area during start-stop stability tests that were performed by cycling the electrode potential between 0 V to 1.8 V for 1000 cycles. Catalyzed support (40% Pt/RuO2-SiO2; 1:1 mole ratio) were tested in a PEFC, resulting in a current density of 750 mA/cm2 at 0.6 Volts, and a maximum power density of 570 mW/cm2. Measurements were conducted at 80 ºC with 75% relative humidity of the inlet gases (H2/O2); Pt loadings were 0.4 mg/cm2 at the cathode and 0.2 mg/cm2 at the anode. Start-stop stability tests for support and catalyzed support performed in RDE and PEFC set-ups have confirmed RuO2-TiO2 support stability. The beginning of life performance was exactly equal to end of life performance (in an MEA that has been subjected to severe start-stop cycling for 10,000 start/stop cycles between 1 V to 1.5 V). This result was in sharp contrast to baseline Pt/C catalyst that showed significant performance deterioration after accelerated stability tests. The Pt/TRO showed minimal loss in performance upon exposure to start-stop cycles. The loss in cell voltage at 1 A/cm2 at 100% RH was almost 700 mV for Pt/C whereas it was only ca. 15 mV for Pt/TRO. 40% RH data (of inlet gases) revealed a similar trend in terms of stability – exceptional stability for Pt/TRO as opposed to very poor stability for Pt/HSAC. These observations were attributed to the much higher stability of the TRO support compared to Carbon. The carbon dioxide concentration in the cathode exit stream during the accelerated degradation test with Pt/TRO (start-stop protocol) was extremely low (between 3 to 10 ppm of CO2). In contrast, the CO2 emission levels from a conventional Pt/C catalyst were found to be approx. 200 ppm. This observation was a clear indicator that the main source of carbon being oxidized to carbon dioxide in an MEA was the carbon catalyst support, and not the gas diffusion layer or the graphite flow fields. Indium tin oxide (ITO) was also evaluated as a catalyst support for PEFCs. Pt/ITO was very stable under start-up/shutdown accelerated degradation protocol (RDE tests in perchloric acid). The ECSA change was less than 4% over 10,000 cycles. The load cycling accelerated protocol (from 0.6 to 0.95 V vs. RHE) resulted in a loss of approximately 34% of the initial ECSA after 10,000 cycles. However, fuel cell testing resulted in a very low performing catalyst. XPS spectroscopy was employed to investigate the changes in the catalysts occuring during fuel cell operation. It was observed a shift of In 3d5/2 and In 3d3/2 peaks towards higher binding energies. This can be explained by the formation of hydroxides or oxy-hydroxides in the surface of the catalyst. O1s spectrum for Pt/ITO catalyst after being operated in the fuel cell, also confirmed the formation of significant amounts of surface hydroxides (12 to 16%). The presence of surface hydroxides in the catalyst increased the electrode resistivity affecting fuel cell performance. NTCNA performed a detailed analysis of transport phenomena (reactants and products to/from the Pt active sites) in both commercial catalyst and Pt/RTO (in order to have a better understanding at the basic level). The proton resistance (Rionomer) in Pt/C and Pt/RTO cathode catalyst layers were 150 and 12 mΩ-cm2, respectively. Pt/RTO catalyst layer has about an order or magnitude lower proton transfer resistance than Pt/C catalyst layer. Since the ionomer/support ratio that was used in formulating the ink for both catalysts was the same (0.9), it is expected that the volumetric coverage of ionomer of both catalysts will be significantly different due to the disparity in the surface areas (Pt/C had ~ 800 m2/g, while Pt/RTO had ~ 50 m2/g). The differences in the ionomer volumetric coverage and the ionomer film thickness may explain the significantly higher proton conductivity in the Pt/RTO catalyst layer when compared to Pt/HSAC. It is therefore very important to optimize the ionomer loadings when synthesizing new catalyst supports (and never rely on values for carbon-based commercial catalysts). Finally, NTCNA has elaborated a cost model for non-carbon support materials considering their durability benefits. Material costs for production of Pt/ RuO2-TiO2 electrodes were compared to Pt/C. RuO2-TiO2 support was more expensive than carbon but the total material cost was still dominated by platinum cost. Though ruthenium is considered a precious metal, its cost is far less than platinum. It should also be noted that ruthenium only makes up 38% of the mass of the support, while the rest is inexpensive TiO2. After considering the durability advantages of Pt/RTO, cost model showed that even with almost double the Pt loading (0.35 vs 0.18 mgPt/cm2), Pt/RTO ($22.7/kWnet) is only slightly more expensive than Pt/C ($21.9/kWnet).

08 HYDROGEN↗

Hydrodynamic behavior of wrapped coil water heater tank

In this work, a numerical investigation using computational fluid dynamics (CFD) has been carried out to analyze the thermal behavior of a water tank integrated to a heat pump water heating system (HPWH). The heat pump condenser is a long coil wrapped around the water tank and insulated from outside from which heat is transferred from the heat pump cycle into the water stored inside the tank. The simulated water tank has a capacity of about 170 L with the charging inlet located at the bottom segment of the tank and the discharging outlet located at the top segment of the tank like commercially available water heaters. The tank was simulated during charging/discharging process with isothermal boundary condition at the tank wall to represent the majority of the process for refrigerant condensation inside the heat pump condenser (excluding superheated and sub-cooled section). Three flow rates were selected to represent low, medium and high flow pattern. Both mean and turbulent flow properties were calculated and analyzed. Heat transfer mechanisms inside the tank are quantified by calculating Richardson and Péclet numbers to show the relative contribution of driving forces. The calculations show that advection is dominant over diffusion. Mixing factor is calculated and presented. It is found that the rate of increase of mixing is nonlinear with the increase in flow rate. Mixing increased by a factor of four when the flow rate increased by a factor of two.

stratification↗

Electromagnetic wave attenuation measurements in a ring-shaped inductively coupled air plasma

An aerocraft with the surface, inlet and radome covered large-area inductive coupled plasma (ICP) can attenuate its radar echo effectively. The shape, thickness, and electron density (N{sub e}) distribution of ICP are critical to electromagnetic wave attenuation. In the paper, an air all-quartz ICP generator in size of 20 × 20 × 7 cm{sup 3} without magnetic confinement is designed. The discharge results show that the ICP is amorphous in E-mode and ring-shaped in H-mode. The structure of ICP stratifies into core region and edge halo in H-mode, and its width and thickness changes from power and pressure. Such phenomena are explained by the distribution of RF magnetic field, the diffusion of negative ions plasma and the variation of skin depth. In addition, the theoretical analysis shows that the N{sub e} achieves nearly uniform within the electronegative core and sharply steepens in the edge. The N{sub e} of core region is diagnosed by microwave interferometer under varied conditions (pressure in range of 10–50 Pa, power in 300–700 W). Furthermore, the electromagnetic wave attenuation measurements were carried out with the air ICP in the frequencies of 4–5 GHz. The results show that the interspaced ICP is still effective to wave attenuation, and the wave attenuation increases with the power and pressure. The measured attenuation is approximately in accordance with the calculation data of finite-different time-domain simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space Laboratory on a Table Top: A Next Generative ECLSS design and diagnostic tool

This paper describes the development plan for a comprehensive research and diagnostic tool for aspects of advanced life support systems in space-based laboratories. Specifically it aims to build a high fidelity tabletop model that can be used for the purpose of risk mitigation, failure mode analysis, contamination tracking, and testing reliability. We envision a comprehensive approach involving experimental work coupled with numerical simulation to develop this diagnostic tool. It envisions a 10% scale transparent model of a space platform such as the International Space Station that operates with water or a specific matched index of refraction liquid as the working fluid. This allows the scaling of a 10 ft x 10 ft x 10 ft room with air flow to 1 ft x 1 ft x 1 ft tabletop model with water/liquid flow. Dynamic similitude for this length scale dictates model velocities to be 67% of full-scale and thereby the time scale of the model to represent 15% of the full- scale system; meaning identical processes in the model are completed in 15% of the full- scale-time. The use of an index matching fluid (fluid that matches the refractive index of cast acrylic, the model material) allows making the entire model (with complex internal geometry) transparent and hence conducive to non-intrusive optical diagnostics. So using such a system one can test environment control parameters such as core flows (axial flows), cross flows (from registers and diffusers), potential problem areas such as flow short circuits, inadequate oxygen content, build up of other gases beyond desirable levels, test mixing processes within the system at local nodes or compartments and assess the overall system performance. The system allows quantitative measurements of contaminants introduced in the system and allows testing and optimizing the tracking process and removal of contaminants. The envisaged system will be modular and hence flexible for quick configuration change and subsequent testing. The data and inferences from the tests will allow for improvements in the development and design of next generation life support systems and configurations. Preliminary experimental and modeling work in this area will be presented. This involves testing of a single inlet-exit model with detailed 3-D flow visualization and quantitative diagnostics and computational modeling of the system.

Ramachandran, N.↗

Grain detachment and transport clogging during mineral dissolution in carbonate rocks with permeable grain boundaries

In this paper, we explore the effect of permeable grain boundaries on carbonate rock dissolution in order to improve our understanding of grain detachment and migration during reactive flow. To do so we investigated the effects of grain size and enhanced reactivity along grain boundaries on global dissolution kinetics. Variations of permeability and porosity were calculated, and exponential relationships were observed in fractured rocks. Our model employed a reactive transport framework based on the Darcy-Brinkman equation to simulate calcite dissolution in carbonate rocks composed of microporous grains and, included fluid transport along grain boundaries. The model includes fluid flow, solute transport by advection–diffusion, heterogeneous reaction between fluid and minerals and grain detachment with subsequent grain transport in macropores. The migration of solid particles due to dissolution was based on cluster analysis and local movement, and the results show that grain detachment can lead to significant decreases in permeability due to the clogging of transport pathways. Microporous media with smaller grain sizes (fine grains in this study) showed a higher average reaction rate than those with coarser grains. In addition, as the overall rates of geochemical processes are commonly affected by the presence of texture heterogeneities such as fractures, a single fracture (macropore) introduced into a microporous matrix composed of permeable grains and grain boundaries was modelled as a large channel connecting the inlet and outlet of the simulation domain. It was found that macropore clogging by grain detachment temporary decreased permeability, lowering the long-term global reaction rates. Lastly, we observed that increases in flow rate can reduce detachment and fracture clogging by reducing local dissolution along grain boundaries.

58 GEOSCIENCES↗

Insights Gained from Testing Alternate Cell Designs

The Idaho National Laboratory (INL) has been researching the application of solid-oxide electrolysis cell for large-scale hydrogen production from steam over a temperature range of 800 to 900ºC. The INL has been testing various solid oxide cell designs to characterize their electrolytic performance operating in the electrolysis mode for hydrogen production. Some results presented in this report were obtained from cells, initially developed by the Forschungszentrum Jülich and now manufactured by the French ceramics firm St. Gobain. These cells have an active area of 16 cm2 per cell. They were initially developed as fuel cells, but are being tested as electrolytic cells in the INL test stands. The electrolysis cells are electrode-supported, with ~10 µm thick yttria-stabilized zirconia (YSZ) electrolytes, ~1400 µm thick nickel-YSZ steam-hydrogen electrodes, and manganite (LSM) air-oxygen electrodes. The experiments were performed over a range of steam inlet mole fractions (0.1 to 0.6), gas flow rates, and current densities (0 to 0.6 A/cm2). Steam consumption rates associated with electrolysis were measured directly using inlet and outlet dewpoint instrumentation. On a molar basis, the steam consumption rate is equal to the hydrogen production rate. Cell performance was evaluated by performing DC potential sweeps at 800, 850, and 900°C. The voltage-current characteristics are presented, along with values of area-specific resistance as a function of current density. Long-term cell performance is also assessed to evaluate cell degradation. Details of the custom single-cell test apparatus developed for these experiments are also presented. NASA, in conjunction with the University of Toledo, has developed another fuel cell concept with the goals of reduced weight and high power density. The NASA cell is structurally symmetrical, with both electrodes supporting the thin electrolyte and containing micro-channels for gas diffusion. This configuration is called a bi-electrode supported cell or BSC. The electrodes are made by freeze-casting, a modified tape casting technique which creates the many micro-channels in the YSZ electrode green tape. This report presents results of the INL’s testing of this new solid oxide cell design as an electrolyzer. Gas composition, operating voltage, and other parameters were varied during testing. Results to date show the NASA cell to be a promising design for both high power-to-weight fuel cell and electrolyzer applications.

08 HYDROGEN↗

Mixing and unmixedness in plasma jets 1: Near-field analysis

The flow characteristics in the near-field of a plasma jet are simulated with a two-fluid model. This model accounts for both gradient-diffusion mixing and uni-directional sifting motion resulting from pressure-gradient-body-force imbalance. This latter mechanism is believed to be responsible for the umixedness observed in plasma jets. The unmixedness is considered to be essentially a Rayleigh-Taylor kind instability. Transport equations are solved for the individual plasma and ambient gas velocities, temperatures and volume fractions. Empirical relations are employed for the interface transfers of mass, momentum and heat. The empirical coefficients are first established by comparison of predictions with available experimental data for shear flows. The model is then applied to an Argon plasma jet ejecting into stagnant air. The predicted results show the significant build-up of unmixed air within the plasma gas, even relatively far downstream of the torch. By adjusting the inlet condition, the model adequately reproduces the experimental data.

Ilegbusi, Olusegun J.↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Kinetic Model for the Reduction of Cu II Sites by NO + NH 3 and Reoxidation of NH 3 -Solvated Cu I Sites by O 2 and NO in Cu-SSZ-13

In this work, a kinetic model is developed for the reduction of Cu II sites by NO + NH 3 and the reoxidation of NH 3 -solvated Cu I sites by O 2 and NO in Cu-SSZ-13. Fourier transform infrared (FTIR) spectroscopy and spatially resolved capillary inlet mass spectrometry (SpaciMS) measurements during transient reactor experiments are utilized to identify the rate parameters associated with NO + NH 3 RHC (reduction half-cycle), proposed to occur via two distinct pathways involving adsorbed NH 3 and gas-phase NH 3 . The resulting NO + NH 3 RHC model is validated using spatiotemporal N 2 measurements covering a wide range of temperatures (200–450 °C) and space velocities (53,000–640,000 h –1 ). N 2 O formation is observed and modeled during NO + NH 3 RHC, with quantitative validation under standard selective catalytic reduction (SCR) conditions. Experimentally measured enthalpic and entropic changes associated with O 2 adsorption on NH 3 -solvated Cu I (ZCu(NH 3 ) 2 ) complexes [ Kamasamudram, K. Catal. Today 2010 , 151 (3–4), 212-222], along with activation energies estimated computationally for the intercage diffusion of ZCu(NH 3 ) 2 complexes [ Paolucci, C. Science 2017 , 357 (6 354), 898-903], are incorporated into a mean field kinetic model for the low-temperature oxidation half-cycle (OHC). Significant NH 3 release is observed during the isothermal oxidation of Cu I sites, attributed to desorption of NH 3 ligands from NH 3 -solvated Cu II dimers (Z 2 Cu 2 (NH 3 ) 4 O 2 ). Reduction of these dimeric complexes leads to the consumption of one NO/Cu II , contradicting the expected reduction stoichiometry. Inclusion of a global Arrhenius rate for the NO titration of Z 2 Cu 2 (NH 3 ) 4 O 2 complexes provides accurate representations of standard SCR on reduced and oxidized catalysts, predicting transient NO and NH 3 consumption between 150 and 250 °C as a function of hydrothermal aging. Deactivation of low-temperature standard SCR by NH 3 is observed at high NH 3 pressures, modeled via the formation of superoxo amino (ZCu(NH 3 ) 3 OO*) complexes during NH 3 titration of Z 2 Cu 2 (NH 3 ) 4 O 2 complexes [ Negri, C. J. Am. Chem. Soc. 2020 , 142 (37), 15884-15896]. The redox kinetic model presented here provides a foundational description of active site redox during low-temperature standard SCR, combining the recent kinetic, spectroscopic, and computational findings on the mechanism of standard SCR over Cu-SSZ-13.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Density Effects on Lock Exchange Flow During a DCC

The High Temperature Test Facility (HTTF) is a scaled, electric model at Oregon State University (OSU) of the Modular High Temperature Gas Reactor (MHTGR) by General Atomics. There are a few major differences between the design and the OSU facility. In the HTTF the reactor pressure vessel and the reactor cavity are in two separate tanks connected by a crossover duct similar to the crossover duct that would be seen between the reactor core and the steam generator in the MHTGR. This feature allows for the facility to open two main break valves simulating a Double-Ended Guillotine Break (DEGB) of the cross over duct, synonymous to a crossover duct break in the MHTGR. The density gradient driven flow phenomena in the HTTF duct can then be studied further. This break would cause a depressurization of the reactor and a loss of flow. It is called the Depressurized Loss of Forced Convection Accident (D-LOFC), also known as the Depressurized Conduction Cool-Down Event for High Temperature Gas Reactors (HTGRs) because heat removal is by conduction through the core and radiation out of the vessel. The HTTF was built and scaled to maintain the highest accuracy for the DCC. Prototypical temperatures with an inlet temperature of 259 deg. C and an outlet temperature of 687 deg. C are maintained in the HTTF. The temperature profile is also maintained in the smaller volume by using a ceramic core. The HTTF uses graphite heaters because the resistive heat produced does not change significantly with temperature . In order to produce a facility of similar temperatures within the allotted budget, sacrifices had to be made in other areas. The HTTF is scaled one-fourth in diameter, one-fourth in height and one-eighth in pressure of the MHTGR. There are also a few limitations for the HTTF. While in the MHTGR, the cavity is filled with air, the HTTF uses highly pure Nitrogen and does not have the ability to simulate a full depressurization. The DCC event is traditionally comprised of multiple stages: depressurization, molecular diffusion and natural circulation. However, this traditional interpretation ignores lock exchange flow which will occur immediately following depressurization and could have significant consequences in the reactor. It was found that the traditional model underestimates the amount of air ingress by at least 660 times according to Oh and Kim in their theoretical research of air ingress. Molecular diffusion also decreases with stratification. Any model that specifies the gases are stratified has further underestimated the air ingress of the DCC event. In addition, molecular diffusion is a much slower process, allowing the reactor to shut down and cool off considerably from operating temperatures. Thus, understanding lock exchange flow, the air ingress concentrations and the time scale is critical to MHTGR research and licensing. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scaling of thermal stratification in outlet plena of SFRs with gallium as a surrogate fluid

Due to its high thermal diffusivity, liquid sodium can develop thermally stratified regions in the hot and cold pools of SFRs under certain off normal operating conditions. The temperature gradients in the fluid give rise to mixed convection flow in which flow velocities result both from pressure gradients and from volume forces induced by density gradients. High thermal diffusivity and low momentum diffusivity leads to reduced thermal mixing and enhanced stratification. Thermal stratification, if not looked carefully in the design, can lead to severe consequences in normal operation with forced coolant circulation and during off-normal natural circulation. The resulting hydraulic and thermal loads can cause the failure modes in structures and components critical for reactor safety. Thermal stratification in the SFR pools can lead to thermal fatigue, which can lead to structural and material failure, or pose serious concerns for the reactor safety. In addition to thermo-structural issues, the reactivity changes are significantly impacted due to density or temperature driven movement of liquid sodium. Temperature changes or gradients in the Upper Instrumentation Structures (UIS) of SFRs can lead to thermal contraction, a case that can lead to positive reactivity insertion after core shut-down. The motivation of this work is to design a scaled down experimental facility which can generate high fidelity data for thermal stratification physics to validate 3-dimensional (3D) Computational Fluid Dynamics (CFD) models. These validated CFD codes can be used to improve the 1-dimensional (1D) system level codes such as SAS4A/SASSYS-1 which are currently not capable of simulating thermal stratification accurately. These improvements in 1D system level SAS4A/SASSYS-1 codes can significantly improve the safety analyses and design of SFRs. The GaTE facility outlet plenum model is designed based on physics based similarities. Thermal stratification physics is governed primarily by the Richardson numbers (Ri). The expected low flow rates during off-normal conditions can lead to a high degree of thermal stratification in the outlet plenum with a corresponding Ri = 530. Therefore, the inlet flow velocities and inlet hydraulic diameter for the gallium coolant entering the test vessel are required to achieve same Ri. The design of test vessel in GaTE facility is finalized to a 1/20. scale outlet plenum height of the ABTR. This design of the test facility will allow the decoupling of the thermal stratification physics at low flow rates with the transient natural circulation. In other words, it will enable effective control to study thermal stratification at very low flow rates. Numerical studies are conducted with a 3D CFD code to examine the thermal behavior of the selected test design. Simulation results show that thermal gradients are present only in the vertical or axial direction which are similar to the behavior reported in previous studies on full scale SFR models. Future work will involve the experimental studies using the GaTE facility with the high fidelity instrumentation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Water Flow Performance of a Superscale Model of the Fastrac Liquid Oxygen Pump

As part of the National Aeronautics and Space Administration's ongoing effort to lower the cost of access to space, the Marshall Space Flight Center has developed a rocket engine with 60,000 pounds of thrust for use on the Reusable Launch Vehicle technology demonstrator slated for launch in 2000. This gas generator cycle engine, known as the Fastrac engine, uses liquid oxygen and RP-1 for propellants and includes single stage liquid oxygen and RP-1 pumps and a single stage supersonic turbine on a common shaft. The turbopump design effort included the first use and application of new suction capability prediction codes and three-dimensional blade generation codes in an attempt to reduce the turbomachinery design and certification costs typically associated with rocket engine development. To verify the pump's predicted cavitation performance, a water flow test of a superscale model of the Fastrac liquid oxygen pump was conducted to experimentally evaluate the liquid oxygen pump's performance at and around the design point. The water flow test article replicated the flow path of the Fastrac liquid oxygen pump in a 1.582x scale model, including scaled seal clearances for correct leakage flow at a model operating speed of 5000 revolutions per minute. Flow entered the 3-blade axial-flow inducer, transitioned to a shrouded, 6- blade radial impeller, and discharged into a vaneless radial diffuser and collection volute. The test article included approximately 50 total and static pressure measurement locations as well as flush-mounted, high frequency pressure transducers for complete mapping of the pressure environment. The primary objectives of the water flow test were to measure the steady-state and dynamic pressure environment of the liquid oxygen pump versus flow coefficient, suction specific speed, and back face leakage flow rate. Initial results showed acceptable correlation between the predicted and experimentally measured pump head rise at low suction specific speeds. Likewise, only small circumferential variations in steady-state were observed from 80% to 120% of the design flow coefficient, matching the computational predictions and confirming that the integrated design approach has minimized any exit volute-induced distortions. The test article exhibited suction performance trends typically observed in inducer designs with virtually constant head rise with decreasing inlet pressure until complete pump head breakdown. Unfortunately, the net positive suction head at 3% head fall-off occurred far below that predicted at all tested flow coefficients, resulting in a negative net positive suction head margin at the design point in water. Additional testing to map the unsteady pressure environment was conducted and cavitation-induced flow disturbances at the inducer inlet were observed. Two distinct disturbances were identified, one rotating and one stationary relative to the fixed frame of reference, while the transition from one regime to the next produced significant effects on the steady state pump performance. The impact of the unsteady phenomena and the corresponding energy losses on the unexpectedly poor pump performance is also discussed.

Skelley, Stephen↗

Effect of Angle of Attack and Exit Nozzle Design on the Performance of a 16-inch Ram Jet at Mach Numbers from 1.5 to 2.0

An investigation of the performance of a 16-inch ram jet engine having a single oblique-shock all-external compression inlet designed for a flight Mach number of 1.8, was conducted in the NACA Lewis 8-by 6-foot supersonic wind tunnel. Data were obtained at Mach numbers from 1.5 to 2.0 and angles of attack from 0 degrees to 10 degrees. Three exit nozzles were used; a cylindrical extension of the combustion chamber, a 4 degrees half-angle converging nozzle with a 0.71 contraction ratio, and a graphite converging-diverging nozzle having a 0.71 contraction ratio plus reexpansion to essentially major body diameter.

EXITS↗

Stability of Enclosed Laminar Flames Studied in Microgravity

In practical combustion systems, the flame is often anchored at the inlet where the fuel is injected into an air duct. This type of system is found in powerplant combustors, gas turbine combustors, and the jet engine afterburner. Despite its successful use, this configuration is vulnerable to adverse flow conditions that can cause the flame to literally lift off from the inlet or even blowout. Poor flame stability is, of course, unwanted, especially where safety has a high priority. Our understanding of the mechanisms that control flame stability is incomplete in part because the interaction of buoyant (i.e., gravity-induced) convection makes it difficult to interpret normal-gravity results. However, a comparison of normal-gravity and microgravity results can provide a clear indication of the influence of forced and buoyant flows on flame stability. Therefore, a joint microgravity study on the stability of Enclosed Laminar Flames (ELF) was carried out by researchers at The University of Iowa and the NASA Lewis Research Center. The microgravity tests were conducted in the Microgravity Glovebox (MGBX), during the STS-87 space shuttle mission in late 1997, using hardware designed and produced at Lewis. The primary objective of the ELF investigation was to determine the mechanisms controlling the stability of round, laminar, gas-jet diffusion flames in a coflow air duct. The study specifically focused on the effect of buoyancy on the flame characteristics and velocities at the lift-off, reattachment, and blowout of the flame. When the fuel or air velocity is increased to a critical value, the flame base abruptly jumps downstream, and the flame is said to have reached its lift-off condition. Flow conditions are such that the flame cannot be maintained at the burner rim despite the presence of both fuel and oxygen. When the velocity is further increased, the flame eventually extinguishes at its blowout condition. In contrast, if the velocity is reduced, the flame base eventually returns to anchor at the burner rim, at a velocity lower than that of lift-off, indicating a hysteresis effect.

Stocker, Dennis P.↗