Search NASA⌕ Search

SEARCH · Search NASA

Results for “LASER SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Oceanographic applications of laser technology

Oceanographic activities with the Airborne Oceanographic Lidar (AOL) for the past several years have primarily been focussed on using active (laser induced pigment fluorescence) and concurrent passive ocean color spectra to improve existing ocean color algorithms for estimating primary production in the world's oceans. The most significant results were the development of a technique for selecting optimal passive wavelengths for recovering phytoplankton photopigment concentration and the application of this technique, termed active-passive correlation spectroscopy (APCS), to various forms of passive ocean color algorithms. Included in this activity is use of airborne laser and passive ocean color for development of advanced satellite ocean color sensors. Promising on-wavelength subsurface scattering layer measurements were recently obtained. A partial summary of these results are shown.

Hoge, F. E.↗

Difference-frequency-based tunable absorption spectrometer for detection of atmospheric formaldehyde

High-sensitivity detection of formaldehyde (CH2O) at 3.5315 micrometers (2831.64 cm-1) is reported with a diode-laser-pumped, fiber-coupled, periodically poled LiNbO3 spectroscopic source. This source replaced the Pb-salt diode laser Dewar assembly of an existing tunable diode-laser absorption spectrometer designed for ultrasensitive detection of CH2O. Spectra are recorded with 2f-modulation spectroscopy and zero-air rapid background subtraction. Initial measurements reported here, determined from multiple measurements of a flowing 7.7 parts per billion by volume (ppbv, parts in 10(9)) CH2O in air mixture, indicate replicate precisions as low as 0.24 ppbv.

Non-NASA Center↗

Optical and Probe Diagnostics Applied to Reacting Flows

We plan to explore three major threads during the fellowship period. The first interrogates the flame synthesis of carbon nanotubes using aerosol catalysts. Laser light scattering will reveal changes in particle size at various heights above the burner. Analysis of the flame gas by mass spectroscopy will reveal the chemical composition of the mixture. Finally, absorption measurements will map the nanotube concentration within the flow. The second thread explores soot oxidation kinetics. Cavity ring-down absorption measurements of the carbonaceous aerosol can provide a measure of the mass concentration with time and, hence, an oxidation rate. Spectroscopic and direct probe measurements will provide the temperature of the system needed for subsequent modeling. The third thread will explore the details of turbulent flame dynamics. Laser induced incandescence will be applied to measurements of soot volume fraction in a 2-d configuration. Analysis of seed tracer particles by planar laser light MIE scattering will reveal the elemental fuel mixture fraction in the flames. Cavity ring-down spectroscopy, a pulsed transient absorption method, will determine the instantaneous mass loading and its fluctuation. Finally, fluorescence measurements will investigate the formation of PAH's in these flames.

Ticich, Thomas M.↗

Spacecraft Cabin Atmospheric Major Constituent Monitoring Using Off-the-Shelf Techniques

Since the beginning of the crewed space exploration program, the National Aeronautics and Space Administration (NASA) recognized the need to monitor the composition of a spacecraft cabin atmosphere. Typically, major constituent monitoring has been limited to nitrogen, oxygen, carbon dioxide, and water vapor. For the International Space Station, mass spectroscopy was selected as the baseline technology for this task. Recently, new techniques for monitoring major atmospheric constituents have matured commercially making them viable for crewed spacecraft applications. These techniques have advantages over the mass spectroscopy and electrochemically-based instruments used on board the /SS and Shuttle. Fast laser diode oxygen analysis, solid-state infrared carbon dioxide detection, and thin-film capacitive humidity detection are among the emerging techniques. Representative instruments employing these techniques have been selected and tested to demonstrate their potential for crewed spacecraft applications. A summary of testing results is provided.

Perry, Jay L.↗

Pressure and Temperature Dependence of the Reaction of Vinyl Radical with Ethylene

This work reports measurements of absolute rate coefficients and Rice-Ramsperger-Kassel-Marcus (RRKM) master equation simulations of the C2H3 + C2H4 reaction. Direct kinetic studies were performed over a temperature range of 300-700 K and pressures of 20 and 133 mbar. Vinyl radicals (H2C=CH) were generated by laser photolysis of vinyl iodide (C2H31) at 266 nm, and time-resolved absorption spectroscopy was used to probe vinyl radicals through absorption at 423.2 nm. Measurements at 20 mbar are in good agreement with previous determinations at higher temperature. A weighted three-parameter Arrhenius fit to the experimental rate constant at 133 mbar, with the temperature exponent fixed, gives k = (7 +/- 1) x 10(exp -l4) cu cm/molecule/s (T/298 K)(exp 2) exp[-(1430 +/- 70) K/T]. RRKM master equation simulations, based on G3 calculations of stationary points on the C4H7 potential energy surface, were carried out to predict rate coefficients and product branching fractions. The predicted branching to 1-methylallyl product is relatively small under the conditions of the present experiments but increases as the pressure is lowered. Analysis of end products of 248 nm photolysis of vinyl iodide/ethylene mixtures at total pressures between 27 and 933 mbar provides no direct evidence for participation of I -methylallyl.

Ismail, Huzeifa↗

Towards the Development of Low Power Arcjet for Use with Green Propellant

Conventional arcjet propellants are hydrazine and ammonia. Both are toxic and environmentally unfriendly, requiring the use of complicated handling logistics and increased cost. If successfully demonstrated in arcjets, the use of green propellants would alleviate these issues. This paper details improvements made to the design of a low-power arcjet to be used in testing. Diagnostic tools to be used to assess thruster performance were also developed. These include emission spectroscopy for the detection of thruster insulator erosion and a two-cord heterodyne laser interferometer to measure electron number densities and estimate the exit velocity of the propellant.

Moeller, Trevor M.↗

Understanding the Space Weathering of Mercury Through Laboratory Experiments

Introduction: Airless surfaces across the solar system are continually modified by energetic particles from solar wind and micrometeoroid bombardment [1,2]. This process is known as space weathering, and it alters the chemical, microstructural, and optical properties of surface regoliths on airless bodies, including Mercury. On the Moon and S-type asteroids, the reflectance spectral signatures of space weathering include reddening (increasing reflectance with increasing wavelength), darkening (lowering of reflectance), and the attenuation of characteristic absorption bands [2]. Such spectral changes are driven by the production of Fe-bearing nanoparticles(npFe) through both solar wind irradiation and micrometeoroid bombardment. While our understanding of space weathering for the Moon and near-Earth S-types asteroids is advanced, insight into how these processes operate on other planetary bodies is limited. In particular, Mercury experiences a uniquely intense space weathering environment than planetary counterparts at 1 AU, including a moreintense solar wind flux and higher velocity micrometeoroid impacts [4]. Additionally, Mercury has a surface composition unique in the inner solar system, including regions of the surface with very low albedo known as the low reflectance material (LRM), which is enriched in carbon, likely graphite, up to 4wt.% [5].In addition, the concentration of Fe across Mercury’s surface islow (<2 wt.%) compared to the Moonor S-type asteroids asteroids[6]. Our understanding of the effects of space weathering on C-rich and Fe-poor phases is limited. Since Fe plays a critical role inthe development of space weathering characteristicson other airless surfaces(e.g., npFe), its limited availability may significantly affect the development of space weathering features in Mercury surface materials. We can simulate space weathering processes in the laboratory to explore their effects on the microstructural, chemical, and spectral characteristics of Mercury surface materials[7]. Here we used pulsed laser irradiation to simulate the short duration, high-temperature events associated with micrometeoroid impacts. We performed coordinated analyses including reflectance spectroscopy and electron microscopy to investigate the spectral, chemical, and microstructural changes in these mercurian analog samples. Methods: For these experiments, we usedforsteritic olivine with varying FeOcontents, a mineral phase proposed to be abundant on the surface of Mercury. We mixed each sample with graphite to simulate LRM regions of the surface. Wesynthesized the olivinesamplesat 1-bar at NASA’s Johnson Space Centerand prepared pressed powder pellets for laser irradiation [8].We prepared three samples, each with a base layer of olivineto maintain structural integrity and topped witha surface layer containing the graphite-olivine mixture: 1) Sample SC-001 San Carlos olivine(Fo90.91),2)Sample F-S-002 with0.05 wt.% FeO olivine, and 3) F-T-004 with 0.53 wt.% FeO olivine. Each sample was mixed with 5 wt.% powdered graphite and had grain sizes ranging from 45to 125μm. We irradiated each sample usinga pulsed Nd-YAG laser, (l=1064 nm, ~6 ns pulse duration, energy of 48 mJ/pulse) while undervacuumat Northern Arizona University. The laser was rastered1x and then 5x over the surfaceof each sample to simulate progressive space weathering. We collected in situreflectance spectra from the samples after each laser pulse witha Nicolet IS50 Fourier-Transform Infrared spectrometer (lfrom 0.65-2.5 μm). We used an FEI Nova NanoSEM200scanning electron microscope (SEM) and a Hitachi TM4000 Plus benchtop SEM at Purdue University to image the surface morphology and topography of the samples. We extracted thin sections for analysis in the transmission electron microscope(TEM)using the FEI Helios NanoLab 660 focused ion beam (FIB) SEM at the University of Arizona.We performed analysis of the microstructural and chemical characteristics of the samples using the 200 keV JEOL 2500 scanning TEM at Johnson Space Center. Reflectance Spectroscopy Results:Reflectance spectra for each sample are shown in Fig. 1.SC-001:The spectrum of the unirradiated sample exhibits a weak 1.0 μm absorption feature, associated with Fe2+in the olivine,and low overall reflectance (Fig. 1a). Thereflectance and the depth of the absorption band increases after 1x laser raster but are at their lowest after 5x laser rasters.F-T-004:The unirradiated sample has a blue-sloped spectrum with low reflectance without identifiable absorption features (Fig. 1b). With progressive laser irradiation, the sample reflectance increases and becomes strongly red-sloped.F-S-002:The unirradiated sample exhibits a dark, blue-slopedspectrum. The brightness of the sample increases significantly from <0.2average reflectance over >0.8 reflectance in the most irradiated sampleand thespectral slope also becomesslightly reddened (Fig. 1c). Microstructural and Chemical Analysis: Two primary alteration textures were observed in the samples exposed to simulated space weathering: 1) fluffy C-rich,and 2) vesiculated melt. The fluffy C-rich texture is composed oflow-densitydeposits distributed across the surface of the sample(Fig. 2A). Analysis of a FIB section extracted from a low-density C-rich region in sample SC-001 reveals multiple globule-type deposits, discrete from stacked graphite, likely produced via melting from the laser irradiation [9].The vesiculated melt textureis smooth and uniformly distributed across isolated regions of the sample surface. The vesicles measure up to 100s of nmin diameter. Analysis of a FIB section from this texture was extracted from sample F-T-004 reveals a layer of amorphous melt material, close to 100 nm thick and uniform across the FIB section (Fig. 2B). Isolated regions of this melt layer contain small nanoparticles, <5 nm in diameter. Chemical analysis through energy dispersive X-ray spectroscopy reveals the composition of this layer is enriched in Si and depleted in Mg and O compared to the underlying sample. Implications for Space Weathering on Mercury: Previous experiments simulating space weathering of Mercury have showndarkening and reddening of spectra[7,10].However, our use of low-Fe materials and graphite to create a sample set more analogous to the mercurian surface. Our results indicate that sample composition plays a significant and important role in the space weathering of Mercury. In particular, our spectral data demonstrates a strong correlation between spectral slope, Fe content, and simulated space weathering. While the variation in FeO content between samples F-S-002 and F-T-004 is <0.6 wt.%, the spectra deviate from flat to strongly red-sloped(F-T-004). This reddeningmay be linked to the presence of very small nanoparticles observed in the melt textures extracted from sample F-T-004. For the SC-001 sample, the fluffy C-rich textures may be developed by the amalgamation of small graphite particles into these unique morphologies. Such observations indicate that space weathering on Mercury may result in both familiar and new microstructural and chemical characteristics. References: [1]Hapke B. (2001) J. Geophys. Res.-Planet.,106,10039–10073. [2]Pieters C.M. and Noble S.K. (2016) J. Geophys. Res-Planet., 121, 1865–1884. [3] Lucey P.G., and Riner, M.A. (2011) Icarus,212, 451-462.[4]CintalaM.J.(1992)J. Geophys. Res.-Planet.,97,947–973.[5]Klima R.L.et al.(2018)Geophys.Res.Letters, 45, 2945–2953. [6]Nittler L.R., et al. (2011) Science 333, 1847-1850.[7]Sasaki S. and Kurahashi E. (2004) Space weathering on Mercury, Adv.Space Res., 33, 2152-2155.[8] Vander KaadenK.E., et al. (2018) LPSCXLIX, Abstract 1230. [9] McGlaun M.L. et al. (2019) LPSCL, Abstract 2019. [10] TrangD.et al. (2018)LPSCXLIX,Abstract2083

M S Thompson↗

Simultaneous Conoscopic Holography and Raman Spectroscopy

A new instrument was developed for chemical characterization of surfaces that combines the analytical power of Raman spectroscopy with the three-dimensional topographic information provided by conoscopic holography. The figure schematically depicts the proposed hybrid instrument. The output of the conoscopic holographic portion of the instrument is a topographical map of the surface; the output of the Raman portion of the instrument is hyperspectral Raman data, from which the chemical and/or biological composition of the surface would be deduced. By virtue of the basic principles of design and operation of the instrument, the hyperspectral image data would be inherently spatially registered with the topographical data. In conoscopic holography, the object and reference beams of classical holography are replaced by the ordinary and extraordinary components generated by a single beam traveling through a birefringent, uniaxial crystal. In the basic conoscopic configuration, a laser light is projected onto a specimen and the resulting illuminated spot becomes a point source of diffuse light that propagates in every direction. The laser beam is rasterscanned in two dimensions (x and y) perpendicular to the beam axis (z), and at each x,y location, the pattern of interference between the ordinary and extraordinary rays is recorded. The recorded interferogram constitutes the conoscopic hologram. Of particular significance for the proposed instrument is that the conoscopic hologram contains information on the z coordinate (height) of the illuminated surface spot. Hence, a topographical map of the specimen is constructed point-by-point by rastering the laser beam in the x and y directions and correlating the x and y coordinates with the z information obtained from the interferograms. Conoscopic imaging is an established method, and conoscopic laboratory instruments for surface metrology are commercially available. In Raman spectroscopy of a surface, one measures the spectrum of laser light scattered inelastically from a laser-illuminated spot on the surface. The wavelengths of the inelastically scattered light differ from that of the incident laser beam by amounts that correspond to the energies of molecular vibrations. The resulting vibrational spectrum can be used to identify the molecules. Raman spectroscopy is a standard laboratory technique for identifying mineralogical, biological, and other specific chemical compositions.

Schramm, Harry F.↗

A Compact, Tunable Near-UV Source for Quantitative Microgravity Combustion Diagnostics

There is a need for improved optical diagnostic methods for use in microgravity combustion research. Spectroscopic methods with fast time response that can provide absolute concentrations and concentration profiles of important chemical species in flames are needed to facilitate the understanding of combustion kinetics in microgravity. Although a variety of sophisticated laser-based diagnostics (such as planar laser induced fluorescence, degenerate four wave mixing and coherent Raman methods) have been applied to the study of combustion in laboratory flames, the instrumentation associated with these methods is not well suited to microgravity drop tower or space station platforms. Important attributes of diagnostic systems for such applications include compact size, low power consumption, ruggedness, and reliability. We describe a diode laser-based near-UV source designed with the constraints of microgravity research in mind. Coherent light near 420 nm is generated by frequency doubling in a nonlinear crystal. This light source is single mode with a very narrow bandwidth suitable for gas phase diagnostics, can be tuned over several 1/cm and can be wavelength modulated at up to MHz frequencies. We demonstrate the usefulness of this source for combustion diagnostics by measuring CH radical concentration profiles in an atmospheric pressure laboratory flame. The radical concentrations are measured using wavelength modulation spectroscopy (WMS) to obtain the line-of-sight integrated absorption for different paths through the flame. Laser induced fluorescence (LIF) measurements are also demonstrated with this instrument, showing the feasibility of simultaneous WMS absorption and LIF measurements with the same light source. LIF detection perpendicular to the laser beam can be used to map relative species densities along the line-of-sight while the integrated absorption available through WMS provides a mathematical constraint on the extraction of quantitative information from the LIF data. Combining absorption with LIF - especially if the measurements are made simultaneously with the same excitation beam - may allow elimination of geometrical factors and effects of intensity fluctuations (common difficulties with the analysis of LIF data) from the analysis.

Peterson, K. A.↗

Raman and Photoluminescence Spectroscopy of Er(3+) Doped Heavy Metal Oxide Glasses

The potential applications of rare-earth ion doped materials include fiber lasers which can be pumped conveniently by infrared semiconductor laser diodes. The host material systems most widely studied are fluoride crystals and glasses because fluorides have low nonradiative relaxation rates due to their lower phonon energies. However, the mechanical strength, chemical durability and temperature stability of the oxide glasses are generally much better than fluoride glasses. The objective of this research was to investigate the optical and spectroscopic properties of Er(3+)-doped lead-germanate and lead-tellurium-germanate glasses. The maximum vibrational energy of lead-tellurium-germanate glasses are in the range of 740-820/cm, intermediate between those of silicate (1150/cm) and fluoride (530/cm) glasses.

Dyer, Keith↗

Instrumental sensing of stationary source emissions

A variety of programs have been conducted within EPA to evaluate the capability of various ground-based remote-sensing techniques for measuring the SO2 concentration, velocity, and opacity of effluents from coal-burning power plants. The results of the remote measurements were compared with the results of instack measurements made using EPA reference methods. Attention is given to infrared gas-filter correlation radiometry for SO2 concentration, Fourier-transform infrared spectroscopy for SO2 concentration, ultraviolet matched-filter correlation spectroscopy for SO2 concentration, infrared and ultraviolet television for velocity and SO2 concentration, infrared laser-Doppler velocimetry for plume velocity, and visible laser radar for plume opacity.

Herget, W. F.↗

Pulsed-discharge carbon dioxide lasers

The purpose is to attempt a general introduction to pulsed carbon dioxide lasers of the kind used or proposed for laser radar applications. Laser physics is an excellent example of a cross-disciplinary topic, and the molecular spectroscopy, energy transfer, and plasma kinetics of the devices are explored. The concept of stimulated emission and population inversions is introduced, leading on to the molecular spectroscopy of the CO2 molecule. This is followed by a consideration of electron-impact pumping, and the pertinent energy transfer and relaxation processes which go on. Since the devices are plasma pumped, it is necessary to introduce a complex subject, but this is restricted to appropriate physics of glow discharges. Examples of representative devices are shown. The implications of the foregoing to plasma chemistry and gas life are discussed.

Willetts, David V.↗

H + O3 Fourier-transform infrared emission and laser absorption studies of OH(X2Pi) radical - An experimental dipole moment function and state-to-state Einstein A coefficients

FTIR emission/absorption spectroscopy is used to measure the relative intensities of 88 pairs of rovibrational transitions of OH(X2Pi) distributed over 16 vibrational bands. The experimental technique used to obtain the Einstein A ratios is discussed. The dipole moment function which follows from the intensity ratios along with Einstein A coefficients calculated from mu(r) is presented.

Nelson, David D., Jr.↗

Quantitative Species Measurements in Microgravity Combustion Flames using Near-Infrared Diode Lasers

Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as for characterizing dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Unfortunately, combustion is highly complicated by fluid mechanical and chemical kinetic processes, requiring the use of numerical modeling to compare with carefully designed experiments. More sophisticated diagnostic methods are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion as well as provide accurate feedback to improve the predictive capabilities of the models. Diode lasers are a natural choice for use under the severe conditions of low gravity experiments. Reliable, simple solid state operation at low power satisfies the operational restrictions imposed by drop towers, aircraft and space-based studies. Modulation wavelength absorption spectroscopy (WMS) provides a means to make highly sensitive and quantitative measurements of local gas concentration and, in certain cases, temperature. With near-infrared diode lasers, detection of virtually all major combustion species with extremely rapid response time is possible in an inexpensive package. Advancements in near-infrared diode laser fabrication technology and concurrent development of optical fibers for these lasers led to their use in drop towers. Since near-infrared absorption line strengths for overtone and combination vibrational transitions are weaker than the mid-infrared fundamental bands, WMS techniques are applied to increase detection sensitivity and allow measurement of the major combustion gases. In the first microgravity species measurement, Silver et al. mounted a fiber-coupled laser at the top of the NASA 2.2-sec drop tower and piped the light through a single-mode fiber to the drop rig. A fiber splitter divided the light into eight channels that directed the laser beam across a methane or propane diffusion jet flame. The light beams were recaptured by a set of gradient index lenses, coupled back into separate fiber optic lines, and transmitted back to detectors and electronics in the instrument package. In these experiments a 6-mm od fiber cable (containing the nine optical fibers) fell with the drop rig. Using separate detection and demodulation channels, spatial and temporal (up to 20 Hz) maps of water vapor and methane concentrations were obtained at differing heights in the flames. While this apparatus was useful from a demonstration standpoint, several drawbacks needed attention before useful scientific measurements could be obtained. First, eight lines of sight are somewhat insufficient for detailing the spatial profiles of the gas. Second, multiple detection channels operating in parallel are both expensive and present a challenge for accurate calibration. As a result, a newer scanning system was developed in our first contract under this program. The primary characteristic of this system is that it contains a single detection channel and achieves "continuous" spatial resolution by scanning the laser beam across the flame region, then directing this beam onto a single detector. Thus spatial measurements are converted to a temporal series of data. The true spatial resolution is limited only by the beam diameter and width of the sweep. In these experiments the beam is focused to about 1-mm diameter and scans across a region up to 4-cm wide.

Silver, Joel A.↗

Below Band-Gap Laser Ablation of Diamond for Transmission Electron Microscopy

A 248-nm excimer laser was used to thin naturally occurring type 1a diamond substrates at normal and glancing (22 deg) incidence. Perforation of a 250 micron thick substrate was achieved in about 15 minutes at normal incidence. Whilst the substrate thinned at glancing incidence was found to have large electron-transparent areas, that thinned at normal incidence required additional argon milling to achieve electron transparency. X-ray photoelectron spectroscopy of the back surface of the diamond failed to detect any graphite or glassy carbon, confirming that damage due to laser ablation occurs only at the incident surface. Samples prepared using this technique imaged in the transmission electron microscope were observed to have retained the nitrogen platelets

Posthill, J. B.↗

NASA Tech Briefs, June 2012

Topics covered include: iGlobe Interactive Visualization and Analysis of Spatial Data; Broad-Bandwidth FPGA-Based Digital Polyphase Spectrometer; Small Aircraft Data Distribution System; Earth Science Datacasting v2.0; Algorithm for Compressing Time-Series Data; Onboard Science and Applications Algorithm for Hyperspectral Data Reduction; Sampling Technique for Robust Odorant Detection Based on MIT RealNose Data; Security Data Warehouse Application; Integrated Laser Characterization, Data Acquisition, and Command and Control Test System; Radiation-Hard SpaceWire/Gigabit Ethernet-Compatible Transponder; Hardware Implementation of Lossless Adaptive Compression of Data From a Hyperspectral Imager; High-Voltage, Low-Power BNC Feedthrough Terminator; SpaceCube Mini; Dichroic Filter for Separating W-Band and Ka-Band; Active Mirror Predictive and Requirement Verification Software (AMP-ReVS); Navigation/Prop Software Suite; Personal Computer Transport Analysis Program; Pressure Ratio to Thermal Environments; Probabilistic Fatigue Damage Program (FATIG); ASCENT Program; JPL Genesis and Rapid Intensification Processes (GRIP) Portal; Data::Downloader; Fault Tolerance Middleware for a Multi-Core System; DspaceOgreTerrain 3D Terrain Visualization Tool; Trick Simulation Environment 07; Geometric Reasoning for Automated Planning; Water Detection Based on Color Variation; Single-Layer, All-Metal Patch Antenna Element with Wide Bandwidth; Scanning Laser Infrared Molecular Spectrometer (SLIMS); Next-Generation Microshutter Arrays for Large-Format Imaging and Spectroscopy; Detection of Carbon Monoxide Using Polymer-Composite Films with a Porphyrin-Functionalized Polypyrrole; Enhanced-Adhesion Multiwalled Carbon Nanotubes on Titanium Substrates for Stray Light Control; Three-Dimensional Porous Particles Composed of Curved, Two-Dimensional, Nano-Sized Layers for Li-Ion Batteries 23 Ultra-Lightweight; and Ultra-Lightweight Nanocomposite Foams and Sandwich Structures for Space Structure Applications.

Source record↗

Coordinated Analysis of Organic Matter in Primitive Meteorites

Carbonaceous chondrites (CC) preserve a diverse range of organic matter formed within cold interstellar environments, the solar nebula, and during subsequent parent body asteroidal processing. This organic matter maintains a unique geochemical and istopic record of organic evolution [1-4]. Bulk studies of organics within CC have revealed a complex array of organic species. However, bulk studies invariably involve solvent extraction, resulting in a loss of spatial context of the host mineral matrix [3, 5]. Correlated in situ chemical and isotopic studies suggest preservation of interstellar organics in the form of spherical, often hollow, micrometer sized organic nano-globules. Nanoglobules often exhibit significant delta 15N and delta D enrichments that imply formation through fractionation of ion-molecule reactions within cold molecular clouds and/or the outer protoplanetary disk [5]. In situ studies such as 6-8 are necessary to understand the organic evolutionary stages of nanoglobules and other components in the nebula and parent body [7]. We carried out coordinated in situ micrometer-scale chemical, mineralogical and isotopic studies of the Murchison (CM2), QUE 99177 (CR3), and Tagish Lake (C2 Ung) CC. These studies were performed using fluorescent microscopy, two-step laser mass spectrometry (microL2MS), NanoSIMS, and Scanning Electron Microscopy (SEM) with Energy Dispersive X-Ray Spectroscopy (EDX). Comparative analysis of three different meteorites will help reveal the effects of parent body processes on the chemistry and isotopic composition of organic matter.

meteorites↗

Advanced Laser Based Measurements in Porous Media Combustion

We present measurements using dual-pump dual-broadband coherent anti-Stokes Raman scattering spectroscopy (DP-DBB-CARS) inside a porous media burner. This work continues our previous measurements in such combustion systems. The existing setup was significantly modified with the aim of providing improved data quality and data rate, reduction of interferences and additional species information. These changes are presented and discussed in detail. The CARS technique was expanded to a dual-pump dual-broadband CARS system which in principle enables acquisition of temperatures together with relative H2/N2- and O2/N2- species concentrations. Experimental complexity was reduced by the use of a modified spectrometer enabling the detection of both signals, vibrational and rotational CARS, with only one detection system.

Tedder, Sarah A.↗