Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOAD DISTRIBUTION - WINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Coordinated Inverter Control to Increase Dynamic PV Hosting Capacity: A Real-Time Optimal Power Flow Approach

High penetrations of distributed photovoltaics (PV) could cause adverse grid impacts, such as voltage violations. The recent development in inverter technologies provides the opportunity to develop control systems to realize effective PV governance and thus to improve dynamic PV hosting capacity for distribution grids. In this paper, a novel distributed energy resource management system (DERMS) solution is proposed by adopting the real-time optimal power flow (OPF) approach for coordinated control of the distributed PV inverters. The proposed approach eliminates the dependence on load knowledge via measurement feedback correction, and it can be implemented in real time. One challenge is that the technique is sensitive to the data availability and integrity of voltage measurements. Therefore, a decentralized DERMS approach is developed by leveraging the concepts of state estimation. The framework and the effectiveness of the solution approach are numerically demonstrated on a real distribution feeder in Southern California.

14 SOLAR ENERGY↗

Use of Operating Agreements and Energy Storage to Reduce Photovoltaic Interconnection Costs: Technical and Economic Analysis

This report presents an analytical methodology to identify alternative options to manage interconnection costs and streamline interconnection timelines for distribution system-connected photovoltaic (PV) systems not co-located with load. Specifically, the report details the methodology and results of an analysis that: 1. Identifies potential grid violations that would be induced by a PV system requesting interconnection to a distribution circuit; 2. Identifies multiple technically viable options for mitigating the potential violations, including infrastructure upgrades, downsizing the PV system size, curtailment of PV, and addition of battery energy storage; 3. Defines the required technical operating parameters of the system in order to mitigate all potential violations (the "Operating Envelope"); 4. Compares the economics of each option, from the PV developer's perspective. The analysis supports the ongoing evolution of interconnection standards for combined PV and energy storage systems by providing a methodology to define allowable maximum export limits during each hour. The methodology presented could be used by utilities as part of the interconnection study process, to inform negotiations with DER developers and the drafting of mutually acceptable interconnection agreements. The resulting technical operating parameters could be included as part of the interconnection service agreement (ISA) between the system owner and the utility company. The companion report to this analysis, Gill et al. (2022), details the envisioned framework for the implementation of the technical operating parameters.

14 SOLAR ENERGY↗

Probabilistic impact of electricity tariffs on distribution grids considering adoption of solar and storage technologies

This study models the role of electricity tariffs on the long-term adoption of photovoltaic and storage technologies as well as the consequent impact on the distribution grid. An adoption model that captures the economic rationality of tariff-driven investments and considers the stochastic nature of individual consumers’ decisions is proposed. This model is then combined with a probabilistic load flow to evaluate the long-term impacts of the adoption on the voltage profiles of the distribution grid. To illustrate the methodology, different components of the electricity tariffs, including solar compensation mechanisms and time differentiation of Time-of-Use (ToU) rates, are evaluated, using a case study involving a section of a medium-voltage network with 118 nodes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Designing the PR100 Study: Puerto Rico Grid Resilience and Transition to 100% Renewable Energy

Puerto Rico has committed to meeting its electricity needs with 100% renewable energy by 2050, along with realizing interim goals of 40% by 2025, 60% by 2040, the phaseout of coal-fired generation by 2028, and a 30% improvement in energy efficiency by 2040 as established in Act 17. [1] To meet these goals and support widespread end-use electrification, the territory must explore how renewable energy and other generation technologies can be developed with energy storage, distributed generation, distribution control, electric vehicles, and energy efficient and responsive loads in each of Puerto Rico's cities and communities. To support Puerto Rico in reaching its renewable energy goals; help ensure energy system resilience against future extreme weather events; improve energy justice; and provide inputs to LUMA Energy's walk, jog, and run approach in its coordinated planning roadmap, the U.S. Department of Energy, National Renewable Energy Laboratory, Argonne National Laboratory, Lawrence Berkeley National Laboratory, Oak Ridge National Laboratory, Pacific Northwest National Laboratory and Sandia National Laboratories propose to evaluate 100% renewable energy pathways through an integrated analysis process. This talk will present steps in designing a two-year study entitled Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy (PR100). [1] U.S. Energy Information Administration (EIA). 2020. Puerto Rico Territory Energy Profile.

100% renewable energy↗

Preparing Distribution Utilities for Utility-Scale Storage and Electric Vehicles: A Novel Analytical Framework

Emerging distributed energy resources (DERs)—such as solar photovoltaics (PV), battery energy storage systems (BESS), and electric vehicles (EVs)—are expected to increase substantially in India in the coming years following policy-driven targets of the Government of India to modernize its electricity system, reduce greenhouse gas emissions (GHGs), and improve air quality. These emerging technologies can pose challenges to distribution utilities, forcing overhauls in planning and operational practices. They can also create challenges in power system infrastructure planning and cause more frequent system operational violations (e.g., network voltage bounds and loading thresholds) if not properly integrated. The impacts on the localized power distribution grid from these emerging technologies manifest in increased infrastructure investments and erratic shifts in demand patterns. These impacts are not yet well understood, and analytic solutions are not readily available. To address these challenges, the National Renewable Energy Laboratory (NREL), in collaboration with BSES Rajdhani Power Ltd. (BRPL), developed an advanced power distribution system impact analysis framework of BRPL’s distribution system. This framework helps analyze the readiness of the power distribution network to accommodate emerging technologies and the potential opportunities they might introduce. The framework has been predominantly set up to evaluate distributed PV, BESS, and EVs. In this collaboration between NREL and BRPL, we developed and evaluated the framework on two distribution feeders in the BRPL territory for various scenarios of BESS and EVs. BESS are evaluated for their effectiveness on the grid to mitigate present and future feeder overloading scenarios, and they are subsequently analyzed for their costs compared to the costs of traditional upgradation measures. Scenarios include assessing the effects of EV density on grid infrastructure upgrades and interlinking EV management with BESS integration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emerging Technologies for Improved Plug Load Management Systems: Learning Behavior Algorithms and Automatic and Dynamic Load Detection

Plug loads are responsible for a significant portion of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them one of the most challenging building end uses to manage. Plug load management systems exist today that utilize smart plugs to meter and control devices at the outlet level, however, their uptake has been relatively slow in part due to the significant labor required for installation and maintenance. Learning behavior algorithms and automatic and dynamic load detection have been identified as two technology areas that could accelerate the adoption of plug load management systems by reducing these labor demands and providing additional energy efficiency and non-energy benefits. Learning behavior algorithms learn occupant behavior and adjust plug load management systems accordingly, allowing for the automatic creation of optimized control schedules. Automatic and dynamic load detection allows a plug load management system to identify devices as they are plugged in to a building and keeps the system up to date as devices are moved throughout a building. In this paper, we present our findings with respect to the current state of these two technologies based on a review of existing research and patents, as well as a series of interviews with companies working in the plug load space. We have found that, as of now, no commercialized solutions exist for these plug load technologies and that more work is needed to bring them to market. In addition, we summarize our findings related to the technology challenges, market barriers, drivers, and opportunities for these technologies moving forward.

30 DIRECT ENERGY CONVERSION↗

Mechanistic modeling of lifetime distribution of SiC/SiC composite claddings

Silicon carbide (SiC) fiber-reinforced SiC matrix (SiC/SiC) composites have emerged as a new material candidate for fuel claddings in light water reactors. Recent studies showed that the load capacity of SiC/SiC materials exhibits a considerable statistical variation. Therefore, reliability analysis plays a critical role in design of SiC/SiC composite claddings. Here, this paper presents a probabilistic model for the lifetime distribution of SiC/SiC composites. The model is anchored by a multiaxial stress-based failure criterion and subcritical damage accumulation mechanism. Based on the kinetics of subcritical damage growth, the lifetime distribution of a laboratory test specimen for any given loading history can be calculated. A finite weakest-link model is used to extrapolate the lifetime distribution of test specimens to full-length claddings. It is shown that the damage accumulation mechanism has a strong influence on the lifetime distribution of the cladding. This finding highlights the importance of understanding the static fatigue behavior of SiC/SiC composites. The present analysis also demonstrates an intricate length effect on the failure probability of the cladding, which is expected to play a crucial role in design extrapolation.

36 MATERIALS SCIENCE↗

EUREICA: Efficient UltRa Endpoint IoT-enabled Coordinated Architecture

The electricity grid has evolved from a physical system to a cyber-physical system with digital devices that perform measurement, control, communication, computation, and actuation. The increased penetration of distributed energy resources (DERs) that include renewable generation, flexible loads, and storage provides extraordinary opportunities for improvements in efficiency and sustainability. However, they can introduce new vulnerabilities in the form of cyberattacks, which can cause significant challenges in ensuring grid resilience. The purpose of this project was to develop a framework ((Efficient, Ultra-REsilient, IoT-Coordinated Assets, or EUREICA)for achieving grid resilience through suitably coordinated assets including a network of Internet of Things (IoT) devices, and a local electricity market (LEM) to identify trustable assets and carry out this coordination. Situational Awareness (SA) of locally available DERs with the ability to inject power or reduce consumption is enabled by the market, together with a monitoring procedure for their trustability and commitment. Experiments conducted during this project demonstrated that, with this SA, a variety of cyberattacks can be mitigated using local trustable resources without stressing the bulk grid. The demonstrations were carried out using a variety of high-fidelity co-simulation platforms, real-time hardware-in-the-loop validation, and a utility-friendly simulator.

14 SOLAR ENERGY↗

Traveling Wave Energy Analysis of Faults on Power Distribution Systems

This paper explores the most important factors that define the Traveling Wave (TW) propagation on distribution systems. The factors considered in this work are: the distance to the fault location, the fault type, and the crossing of system elements (such as regulators, capacitor banks, laterals, and extra loads within the protection zones). This work uses a realistic, yet simplified, distribution system composed of two protection zones, in which, several combinations of the previously mentioned factors are considered. The simulated fault measurements undergo a signal processing stage in which, first, they are decomposed into independent modes using the Karrenbauer transform. Second, a time–frequency representation is obtained using the Stationary Wavelet Transform (SWT), dividing the signal into several frequency bands. Finally, the Parseval’s Energy (PE) theorem is applied to calculate the signal energy in each frequency band. A qualitative analysis is performed based on the previously calculated energies to outline which are the factors that most affect the TW energy during propagation. The results show that distance, the presence of regulators, either in the propagation path or upstream, and the type of fault are the main factors that affect TW propagation across the system, and therefore they should be considered for TW-based protection schemes for distribution systems.

Jiménez-Aparicio, Miguel (ORCID:000000016864461X)↗

Scalable Hybrid Classification-Regression Solution for High-Frequency Nonintrusive Load Monitoring

Residential buildings with the ability to monitor and control their net-load (sum of load and generation) can provide valuable flexibility to power grid operators. We present a novel multiclass nonintrusive load monitoring (NILM) approach that enables effective net-load monitoring capabilities at high-frequency with minimal additional equipment and cost. The proposed machine learning based solution provides accurate multiclass state predictions while operating at a faster timescale (able to provide a prediction for each 60- Hz ac cycle used in US power grid) without relying on event-detection techniques. We also introduce an innovative hybrid classification-regression method that allows for the prediction of not only load on/off states but also individual load operating power levels. A test bed with eight residential appliances is used for validating the NILM approach. Results show that the overall method has high accuracy, good scaling and generalization properties.

feature extraction↗

Heavy-Duty Vehicle Activity Updates for MOVES Using NREL Fleet DNA and CE-CERT Data

The U.S. Environmental Protection Agency's (EPA's) Motor Vehicle Emission Simulator (MOVES) is a publicly available tool used by researchers and policymakers to help understand motor vehicle emission sources at a national, county, and project level. Estimates of heavy-duty activity in the most recent version of the model at the time this work was conducted, MOVES2014, was identified as an area in need of improvement. The start activity in MOVES2014 is based on a limited and dated data set. In addition, MOVES2014 relies on drive cycles that represent on-network activity but do not account for idling activity that occurs on off-network roads, such as at a distribution center, while the truck is queuing or during loading and unloading. As a result, MOVES2014 may currently underestimate the number of starts and idle and soak time for heavy-duty trucks in real-world operation. The National Renewable Energy Laboratory (NREL) has previously leveraged its expansive Fleet DNA database of heavy-duty vehicles to idle and start activity for six of the nine heavy-duty vehicle source types of classes in the MOVES model. The data available in Fleet DNA from 416 conventional, diesel-powered vehicles provided activity estimates from more than 120,000 hours of operation throughout 14,682 vehicle days between October 2006 and January 2016. NREL calculated start fraction, starts per day, soak fraction, and idle fraction by hour of the day for each vehicle type, state, and vocation, and provided results in .CSV files that can be translated to MOVES table inputs. The idle and start activity from this initial analysis of Fleet DNA data was used to develop default idle and start data for heavy-duty vehicles in MOVES3. Satisfied with the results from the Fleet DNA data used for MOVES3, the EPA asked NREL to extend this start/soak/idle analysis using additional data from a larger number of vehicles for a potential future update to the MOVES model. Such a data set was achieved from a project led by the University of California at Riverside, College of Engineering, Center for Environmental Research & Technology (CE-CERT) and funded by California Air Resources Board. Specifically, this data set consists of 90 heavy-duty vehicles operated mainly in California, which can be separated into five of the nine heavy-duty vehicle classes in the MOVES model. In addition, the heavy-duty activity database collected by CE-CERT provided activity estimates from more than 44,000 hours of operation throughout 4,724 vehicle days between November 2014 and September 2016. This report details the analysis of the heavy-duty activity database collected from the University of California at Riverside by providing graphical analysis and context for the start, soak, and idle distributions. The comparison of the related results from both the Fleet DNA and CE-CERT data sets are documented as well.

33 ADVANCED PROPULSION SYSTEMS↗

Power Quality and Stability in a Cluster of Microgrids with Coordinated Power and Energy Management

Distributed Energy Resources (DER) such as photovoltaic (PV) systems and battery energy storage systems (BESS) can be operated collectively as microgrids. Microgrids can be effective in meeting local load requirements as well as in improving the power quality and stability in a modern power distribution system. Multiple microgrids can also be operated in a coordinated manner as a cluster, to improve the resiliency of the power distribution system. In the event of an outage caused by a transmission system failure, the microgrids in a cluster can use their distributed generation capacity and energy storage resources to recover and extend power availability to the critical loads in the system. In this paper, an illustrative cluster of two microgrids based on the IEEE 13-bus model with DERs has been used, to demonstrate the operation of the concept using real-time simulations. Using real-time simulations, capabilities such as switching reconfiguration following faults, identification of optimal DER placement for effective power quality management, and power electronic controller validation have been demonstrated. For the two-microgrid cluster, this paper also presents improvements in load voltage quality and

Chowdhury, Prithwiraj Roy↗

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

Prediction for Pressure Differential Across HEPA Filter Media Based on Media Characteristics and Particle Size Distribution

A new method for predicting the pressure drop across High Efficiency Particulate Air (HEPA) filter media is proposed based upon mass deposited onto the filter and known physical characteristics of the filter media. Detailed are the methods used in conjunction with current filter loading models to predict the pressure drop, as well as tests conducted to validate the methods. The benefit of a prediction model for practical use lies in the manufacturing and service life of nuclear grade HEPA filters. HEPA filters for use in nuclear facilities have a prescribed expiration date and a maximum allowable operating pressure drop. Therefore, the ability to predict the pressure drop across a filter and relate it to an expected length of service time can enable a reduction in wasted filters. This will allow for more informed decisions to be made based upon the dictated life cycle of the filters. Also, understanding and predicting how the pressure drop of HEPA filter media behaves as a function of physical characteristics and loaded mass can assist in future design and manufacturing of filter media. Currently, most existing pressure drop models are either computationally based or analytical methods relying on data gathered during tests. Neither are practical for prediction; the computational methods are difficult to implement, and the current analytical methods are more useful as tools for analysis. The current analytical model developed by Bergman et al. is based upon the pressure drop from each media fiber and modeling the deposited particles as newly formed fibers. Using Bergman's model and the media properties, air properties, and known aerosol particle size distribution, a pressure drop curve as a function of loaded mass can be created. This curve implies initial loading in the depth of the filter media with a transition to pure surface loading on the filter face, and a sensitivity to an evolving particle size distribution as mass continues to load onto the filter. To implement the predictive model, knowledge of the mean filter fiber diameter and porosity of the filter media is required. Traditionally, the mean fiber diameter is calculated as an effective diameter from prior media testing, however, in this study a Scanning Electron Microscope (SEM) technique is used to acquire this variable. Validation of the predictive model is provided by flat sheet media tests under a controlled environment with a measured particle size distribution of the challenge aerosol and shows reasonable preliminary agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distributed fiber optic strain sensing of bending deformation of a well mockup in the laboratory

Well integrity is critical to the safety and success of subsurface energy exploration and management, as leakage of fluids from subsurface reservoirs is often induced by compromised wells. This study investigates bending deformation of a mockup of an oil/gas well that is subjected to loads expected in deviated wells under reservoir compaction and assesses the feasibility of utilizing distributed fiber optic strain sensing to monitor the deformation. Here, a well mockup, which consists of outer and inner steel pipes with a cemented annulus, is tested under three-point bending loading and its strain and curvature development is monitored by Brillouin optical time domain reflectometry/analysis (BOTDR/A) as well as optical frequency domain reflectometry (OFDR). The primary objective of this research is to assess the strain sensing performance of newly fabricated fiber optic cables and to identify key cable characteristics which could improve the quality of distributed strain measurements with BOTDR/A. Results show that the tight-buffered cable is best suited for strain sensing as its maximum errors in the strain measurement were -36% and -24% against conventional sensors at the maximum elastic and plastic bending loads, respectively, whereas those of the non-tight-buffered cable were -45% and -71%, respectively. Similar trends were obtained in the bending curvature measurement. The detailed design of the tight-buffered cable is presented to elucidate key characteristics of such a cable, which will facilitate accurate distributed strain sensing in oil and gas wells.

42 ENGINEERING↗

Simulation-Based Analysis of Feeder Operation with Different PV Smart Inverter Functions on an Actual Distribution System: Preprint

High penetration of photovoltaics (PV) in distribution feeders can cause problems, such as overvoltage, reverse power flow, and large net load changes. Traditional voltage regulation devices, such as capacitors and voltage regulators, can solve some of these problems but might have some delays. Today, smart inverters are gradually being used to provide voltage regulation and frequency support in distribution systems. Different smart inverter settings have been recommended in various rules and standards; however, the potential benefits and their impacts on distribution system operation are not well compared and studied. This paper presents a comparison of different smart inverter settings as applied to a distribution system. An actual feeder model from San Diego Gas & Electric Company is used to conduct the simulation. Additionally, a load disaggregation method is proposed to disaggregate the load and PV profile for each load location using advanced metering infrastructure net load measurements. Then, different smart inverter settings are applied to the PV systems in the feeder, and the simulation results are compared. The results show that the implementation of specific functions of smart inverters can reduce voltage exceedances, and the utility can determine the specific inverter setting based on its operational requirements.

distribution system↗

Optimal Storage Response to Utility Tariff Structures and Potential Use of Capacity Charges

Energy storage is increasingly being deployed in behind-the-meter use cases, partially in response to falling lithium-ion prices and new utility tariff structures. Utilities are grappling with new tariff design in the presence of distributed energy resources (DER), trying to motivate, fairly price the contribution of, and, in some cases, discourage, certain operation of DER. There are opportunities for energy storage under emerging tariff structures, but utility net load management objectives for storage remain unclear. Diverse tariff structures motivate the use of energy storage to provide one or a combination of: energy arbitrage, energy shifting, solar self-consumption, and import shaving. This paper formulates a linear optimization to demonstrate the optimal storage tariff response, examining customer net load metrics under diverse utility tariff structures, such as time-of-use, net metering, feed-in tariffs, zero export tariffs, and demand charges. A key contribution of this paper is the introduction and examination of a capacity charge as mechanism that can both motivate reductions in both peak import, and exports, along with greater load levelling.

behind-the-meter↗

The good, the bad, and the ugly: Data-driven load profile discord identification in a large building portfolio

Reducing the overall energy consumption and associated greenhouse gas emissions in the building sector is essential for meeting our future sustainability goals. Recently, smart energy metering facilities have been deployed to enable monitoring of energy consumption data with hourly or subhourly temporal resolution. This unprecedented data collection has created various opportunities for advanced data analytics involving load profiles (e.g., building energy benchmarking programs, building-to-grid integration, and calibration of urban-scale energy models). These applications often need preprocessing steps to detect daily load profile discords, such as: 1) outliers due to system malfunctions (the bad) and 2) irregular energy consumption patterns, such as those resulting from holidays (the ugly) compared to normal consumption patterns (the good). However, current preprocessing methods predominantly focus on filtering using statistical threshold values, which fail to capture the contextual discords of daily profiles. In addition, discord detection algorithms in building research are often aimed at finding individual building-level discords, which are not suitable at a large scale. Thus, here, we develop a method for automated load profile discord identification (ALDI) in a large portfolio of buildings (more than 100 buildings). Specifically, ALDI 1) uses the matrix profile (MP) method to quantify the similarities of daily subsequences in time series meter data, 2) compares daily MP values with typical-day MP distributions using the Kolmogorov-Smirnov test, and 3) identifies daily load profile discords in a large building portfolio. We evaluate ALDI using the metering data of both an academic campus and a residential neighborhood. Our results demonstrate that ALDI efficiently discovers measurement errors by system malfunctions and low energy consumption days in the academic campus portfolio, and it detects unique load shape patterns likely driven by occupant behavior and extreme weather conditions in the residential neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗