Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leak Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Advancement Of Tritium Powered Betavoltaic Battery Systems FY16 EOY Report

The goal of this work is to increase the power output of tritium-powered betavoltaic batteries and investigate the change in power output and film resistance in real-time during tritium loading of adsorbent films. To this end, several tritium-compatible test vessels with the capability of measuring both the resistivity of a tritium trapping film and the power output of a betavoltaic device in-situ have been designed and fabricated using four electrically insulated feedthroughs in tritium-compatible load cells. Energy conversion devices were received from Widetronix, a betavoltaic manufacturing firm based in Ithaca, NY. Thin films were deposited on the devices and capped with palladium to facilitate hydrogen loading. Gold contacts were then deposited on top of the films to allow resistivity measurements of the film during hydrogen loading. Finally, the chips were wire bonded and installed in the test cells. The cells were then baked-out under vacuum and leak checked at temperature to reduce the chances of tritium leaks during loading. Following the bake-out, IV curves were measured to verify no internal wires were compromised, and the cells were delivered to Tritium for loading. Tritium loading is anticipated in October, 2017.

07 ISOTOPE AND RADIATION SOURCES↗

OES CO 2 Pipeline FEED Project Design Basis Memorandum

The OES CO₂ Pipeline project will move captured carbon dioxide from two ethanol facilities near Gibson City, Illinois, roughly 7.8 miles southeast to three injection wells outside Anchor, where it will be permanently stored underground. The system is designed to handle up to 4.5 million metric tonnes per year of dense-phase CO₂ at pressures up to 2,500 psig, using 16-inch mainline pipe and 10.750-inch laterals made from API 5L X-60 and X-65 steel. Wall thicknesses vary depending on location, with thinner pipe in open country, heavier wall at road crossings, and the heaviest where the pipe passes under highways or railroads via horizontal directional drill. The pipe gets a fusion-bonded epoxy coating, with an added abrasion-resistant layer wherever it's bored or drilled. Major water crossings will use HDD rather than open trenching. The pipeline will be cathodically protected, equipped with SCADA-compatible pressure and temperature instrumentation, and monitored for leaks using a computational pipeline monitoring system per API RP 1130. Hydrostatic testing will be performed at 1.25 times design pressure, and an ILI caliper run will follow to catch any construction defects. Several items, including fracture toughness requirements, specific NDE methods, and ILI tool selection, are left for the detailed design phase. The whole system falls under 49 CFR Part 195 and ASME B31.4, and Gulf Interstate Engineering prepared this document as the FEED-level design basis under the CarbonSAFE Phase III program.

09 BIOMASS FUELS↗

NASA/ASEE Summer Faculty Fellowship Program. 1991 Research Reports

Reports from the NASA/ASEE Summer Faculty Fellowship Program are presented. The editors are responsible for selecting appropriately qualified faculty to address some of the many problems of current interest to NASA Kennedy. Some representative titles are as follows: Development of an Accelerated Test Method for the Determination of Susceptibility to Atmospheric Corrosion; Hazardous Gas Leak Analysis in the Space Shuttle; Modeling and Control of the Automated Radiator Inspection Device; Study of the Finite Element Software Packages at KSC; Multispectral Image Processing for Plants; Algorithms for Contours Depicting Static Electric Fields during Adverse Weather Conditions; Transient Study of a Cryogenic Hydrogen Filling System; and Precision Cleaning Verification of Nonvolatile Residues by using Water, Ultrasonics, and Turbidity Analyses.

Hosler, E. Ramon↗

Analytical Modeling of Variable Density Multilayer Insulation for Cryogenic Storage

A unique foam/Multilayer Insulation (MLI) combination concept for orbital cryogenic storage was experimentally evaluated at NASA Marshall Space Flight Center (MSFC) using the Multipurpose Hydrogen Test Bed (MHTB). The MLI was designed for an on-orbit storage period of 45 days and included several unique features such as: a variable layer density and larger but fewer perforations for venting during ascent to orbit. Test results with liquid hydrogen indicated that the MLI weight or heat leak is reduced by about half in comparison with standard MLI. The focus of this paper is on analytical modeling of the Variable Density MLI (VD-MLI) on-orbit performance (i.e. vacuum/low pressure environment). The foam/VD-MLI combination model is considered to have five segments. The first segment represents the optional foam layer. The second, third, and fourth segments represent three MLI segments with different layer densities. The last segment is considered to be a shroud that surrounds the last MLI layer. Two approaches are considered. In the first approach, the variable density MLI is modeled layer by layer while in the second approach, a semi-empirical model is applied. Both models account for thermal radiation between shields, gas conduction, and solid conduction through the layer separator materials.

Hedayat, A.↗

Effect of External Pressure Drop on Loop Heat Pipe Operating Temperature

This paper discusses the effect of the pressure drop on the operating temperature in a loop heat pipe (LHP). Because the evaporator and the compensation chamber (CC) both contain two-phase fluid, a thermodynamic constraint exists between the temperature difference and the pressure drop for these two components. As the pressure drop increases, so will the temperature difference. The temperature difference in turn causes an increase of the heat leak from the evaporator to the CC, resulting in a higher CC temperature. Furthermore, the heat leak strongly depends on the vapor void fraction inside the evaporator core. Tests were conducted by installing a valve on the vapor line so as to vary the pressure drop, and by charging the LHP with various amounts of fluid. Test results verify that the LHP operating temperature increases with an increasing differential pressure, and the temperature increase is a strong function of the fluid inventory in the loop.

Jentung, Ku↗

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗

NASA Engineering and Safety Center Technical Bulletin No. 20-07: Evaluating and Mitigating Liner Strain Spikes in COPV's

Unexpected cracking and leaking in bonded composite overwrapped pressure vessel (COPV) liners occurring in recent test programs have been attributed to liner strain spikes observed through measurement and predicted by analysis. Diminished load transfer between the liner and composite overwrap can lead to localized excessive liner yielding in the dome section. This diminished constraint can occur due to yielding of the adhesive or a manufacturing unbond defect. COPVs should be assessed for susceptibility to this new failure mode.

Evaluating↗

Energy 101: Home Energy Assessment

A home energy checkup helps owners determine where their house is losing energy and money - and how such problems can be corrected to make the home more energy efficient. A professional technician - often called an energy auditor - can give your home a checkup. You can also do some of the steps yourself. Items shown here include checking for leaks, examining insulation, inspecting the furnace and ductwork, performing a blower door test and using an infrared camera.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Statistical Analysis of CO 2 Exposed Wells to Predict Long Term Leakage through the Development of an Integrated Neural-Genetic Algorithm

The objective of this project is to develop a computerized statistical model with the Integrated Neural-Genetic Algorithm (INGA) for predicting the probability of long-term leak of wells in CO 2 sequestration operations. This object has been accomplished by conducting research in three phases: 1) data mining of CO 2 -explosed wells, 2) INGA computer model development, and 3) evaluation of the predictive performance of the computer model with data from field tests. Data mining was conducted for 510 wells in two CO 2 sequestration projects in the Texas Gulf Coast region. They are the Hasting West field and Oyster Bayou field in the Southern Texas. Missing wellbore integrity data were estimated using an analytical and Finite Element Method (FEM) model. The INGA was first tested for performances of convergence and computing efficiency with the obtained data set of high dimension. It was concluded that the INGA can handle the gathered data set with good accuracy and reasonable computing time after a reduction of dimension with a grouping mechanism. A computerized statistical model with the INGA was then developed based on data pre-processing and grouping. Comprehensive training and testing of the model were carried out to ensure that the model is accurate and efficient enough for predicting the probability of long-term leak of wells in CO 2 sequestration operations. The Cranfield in the southern Mississippi was select as the test site. Observation wells CFU31F2 and CFU31F3 were used for pressure-testing, formation-logging, and cement-sampling. Tools run in the wells include Isolation Scanner, Slim Cement Mapping Tool (SCMT), Cased Hole Formation Dynamics Tester (CHDT), and Mechanical Sidewall Coring Tool (MSCT). Analyses of the obtained data indicate no leak of CO 2 cross the cap zone while it is evident that the well cement sheath was invaded by the CO 2 from the storage zone. This observation is consistent with the result predicted by the INGA model which indicates the well has a CO 2 leak-safe probability of 72%. This comparison implies that the developed INGA model is valid for future use in predicting well leak probability.

97 MATHEMATICS AND COMPUTING↗

NASA’s Space Launch System Stands Ready on Doorstep of Maiden Voyage Launch and Progress Made to Future Missions

NASA and its partners made significant progress towards the Artemis I launch in 2022. The integrated Space Launch System (SLS)vehicleand Orion spacecraft were first rolled out of the Vehicle Assembly Building (VAB) at NASA’s Kennedy Space Center (KSC) in March. SLS is a super heavy-lift vehicle to send large, strategic payloads to the Moon, Mars, and beyond. It isthebackbone of the Artemis human lunar exploration program. Rollout transported the vehicle to Launch Pad 39B for a series of tests, including the wet dress rehearsal (WDR). Multiple attempts were required to complete WDR, each building on the one before. Following the WDR campaign, NASA teams refined hardware and launch procedures, and the vehicle was prepared for its first launch attempt scheduled for August 29. Challenges with the weather and hardware resulted in a scrub on the 29th, and the second attempt was set for Sept. 3. A hydrogen leak on the tail service mast umbilical forced a scrub. NASA teams completed repairs and testing on the vehicle on Launch Pad 39B to preserve a launch attempt at the end of September. Managers chose to return the vehicle to the VAB to protect it fromthe threat of Hurricane Ian. Within the VAB, NASA further inspected and prepared SLS for selected November windows. In addition to progress to the Artemis I mission, significant progress was made on the Artemis II and Artemis III rockets. Progress was also made towards on the Block 1B and Block 2 variants, beginning on the fourth and ninth flight, respectively. Both variants will provide significant improvements in both launch mass and mission flexibility to multiple destinations. This paper will discuss Artemis I vehicle integration, testing, and available results from the launch campaign to date.

Bruce Askins↗

Transportation Package Seal Performance in Beyond Design Basis Thermal Exposures - 12472

The Nuclear Regulatory Commission (NRC) technical report, NUREG/CR-6886, 'Spent Fuel Transportation Package Response to the Baltimore Tunnel Fire Scenario', describes, in detail, an evaluation of the potential for a theoretical release of radioactive material from three different spent nuclear fuel (SNF) transportation packages, had they been exposed to the Baltimore tunnel fire that occurred in July of 2001. This evaluation determined the temperatures of various components of the packages, including the seals, using temperatures resulting from models of the Baltimore tunnel fire (as boundary conditions) and finite element models of the SNF packages. For two of the packages evaluated, the analyses indicated that the seals used would have exceeded their continuous-use rated service temperatures, meaning the release of radioactive material could not be ruled out with available information; However, for both of the packages evaluated, the analysis determined, by a bounding calculation, that the maximum potential release was well below the regulatory requirements for releases from a SNF package during the hypothetical accident condition (HAC) sequence of events in 10CFR Part 71. The NRC is investigating the performance of seals in SNF transportation packages exposed to fires that could exceed the HAC fire described in 10CFR Part 71, such as the Baltimore Tunnel Fire that occurred in 2001. The performance of package seals is important for determining the potential release of radioactive material from a package during a beyond-design-basis accident. The seals have lower temperature limits than other package components and are the containment barrier between the environment and the cask contents. The NRC Office of Nuclear Regulatory Research contracted the National Institute of Standards and Technology (NIST) to conduct small-scale thermal testing to obtain experimental data of the performance of seals during extreme temperature exposures. The experimental testing consisted of several small-scale pressure vessels fabricated with a modified ASME flange design and tested metallic and elastomeric seals, similar to those that might be used on an actual SNF transportation package. The vessels were heated in an electrical oven to temperatures as high as 800 deg. C (1472 deg. F), exceeding the rated temperatures of the seals in question. This paper will provide a summary of the testing conducted and present test results and conclusions. Fifteen metallic and elastomeric seal performance tests including two shakedowns were performed under beyond-design-basis thermal exposure conditions; twelve tests used metallic seals, two used ethylene-propylene seals, and one used a Teflon seal. Of the five repeat metallic-seal tests (Tests No.2, 3, 4, 8, and 9), leakage (decreasing vessel pressure) was observed in three of the tests (Tests No.3, 4, and 8) during the 9 h 800 deg. C (1472 deg. F) exposure. The times when the leakage occurred (the vessel pressure started to decrease) varied in the three tests performed. The two shakedown tests were conducted using a 30 min and 4 h exposure to 800 deg. C (1472 deg. F), respectively, and the seal appeared to hold vessel pressure. No leakage (unchanged vessel pressure within the pressure measurement uncertainty) was also observed in the two metallic seal tests that used 100 deg. C incremental heating from 427 deg. C (800 deg. F) to 627 deg. C (1160 deg. F) and from 427 deg. C (800 deg. F) to 727 deg. C (1340 deg. F), respectively, with at least 9 h exposure to each temperature increment. Three repeat metallic seal tests were also conducted at the seal maximum operating temperature of 427 deg. C (800 deg. F) for 9 h. The seal maintained vessel pressure within the measurement of the pressure transducer in all three tests. No leakage was observed in one ethylene-propylene seal tested at 300 deg. C (572 deg. F) for more than 20 hours; however, leakage was found in another ethylene-propylene seal tested at 450 deg. C (842 deg. F) for more than 20 hours (Test No.15). Leakage was also observed in the test (Test No.12) that used a TFE seal subject to 300 deg. C (572 deg. F) exposure. In these fifteen tests the temperature and time exposure variables were changed to map the performance of the metallic and polymeric seals at elevated temperatures beyond the rated operating temperatures. Both the metallic and polymeric seals were able to hold pressure even after leaks were detected and no catastrophic seal failure (i.e., a rapid release of pressure to atmospheric) occurred. Further testing on the polymeric seals would need to be performed to confirm the results in these tests.(authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High temperature ceramic heat exchanger for solid oxide fuel cell

A ceramic heat exchanger with high effectiveness and low-pressure drop has been developed for application as a cathode air preheater for a Solid Oxide Fuel Cell (SOFC). At the operating conditions of SOFCs, typical metallic alloys as those used in commercial heat exchangers may undergo chromium volatilization, which is a known cathode degradation mechanism that reduces SOFC performance and life. Use of ceramics such as alumina or alumina-silicate instead of chromium-containing metal is one approach to eliminate the effects of chromium on the SOFC cathode. This project leverages the geometric design of a heat exchanger previously prototyped and tested [1] to fabricate a novel heat exchanger made from a ceramic material. All calculations of heat exchanger performance requirements are based on state of the art SOFC operating conditions. The alumina-silicate material selected to fabricate the modular prototype heat exchanger was made via a heat transfer based trade-off analysis that shows that for low pressure-drop devices, flow convection is the limiting heat transfer mechanism, and therefore wall conductivity becomes less relevant to heat transfer effectiveness. The modular design presented allows for incremental aggregation of modules to target a broad range of operating conditions typical of present and upcoming SOFC applications (e.g., 25 to 400 kWe). The completed prototype was subjected to a series of static leak/pressure tests, dynamic pressure drop tests both at ambient and realistic service temperature conditions, and finally to a matrix of heat transfer experiments to fully characterize its heat transfer effectiveness (including tests at hot gas temperatures up to 1033 K or 1400oF). The stand-alone system was demonstrated in the laboratory to successfully satisfy the design criteria at realistic operating conditions, showing a total pressure drop at the design flow of 8 g/sec of 6 kPa (vs. 3.45 kPa approximate requirement). It was also shown to have heat transfer effectiveness of 76% (with 73% being the design requirement). Moreover, the unit was shown to operate leak-free, and the ceramic elements and seals were capable of withstanding the thermal cycling resulting from the testing procedure. The heat exchanger was then integrated into a modified fuel cell test stand and tested at steady state operation. Unfortunately, the level of performance achieved was lower than expected based on laboratory performance tests. This appears to have been the result of an unforeseen loosening of a heat exchanger structural component, which resulted into a leak that prevented proper supply of hot gas to the heat exchanger. However, in general terms, the heat exchanger/fuel cell integration process provides confidence that a future application of the unit with a SOFC is feasible, assuming structural issues are addressed. It is considered that the difficulties encountered at the last stage of the program provided invaluable input in locating shortcomings of the mechanical design and integration approach. A portion of this work was presented at the ASME Power & Energy Conference, in Charlotte, NC, on June 28th 2016 in a paper entitled “Development of a Ceramic Heat Exchanger for Application as Solid Oxide Fuel Cell Cathode Air Preheater” and the corresponding paper was published in the Proceedings of the ASME 2016 Power & Energy Conference, Paper No.: PowerEnergy2016-59333 [8].

20 FOSSIL-FUELED POWER PLANTS↗

LLNL HEPA Filter Support of Nuclear Facility Safety R&D (FY12)

The ceramic HEPA filter project has been a successful and innovative project. This report contains information from the work from FY12 funding, as well as remaining FY11 funding. Of note, a total of 12 patents for the ceramic HEPA filter program have been filed, and an additional record of invention has been prepared with a provisional patent to follow. This project supports development of a ceramic HEPA filter technology to benefit DOE nuclear facilities by providing lower life-cycle costs and reducing or eliminating costs associated with Safety Class and Safety Significant systems in nuclear facilities. The satisfactory performance of ceramic filters in a fire could significantly reduce costs of support systems associated with mitigating a release, such as fire suppression, fire detection and alarm, and internal building structure. In nuclear safety, the best way to provide protection to public, workers and the environment is to provide a barrier between the hazard and the receptors. A passive engineered design feature is the best barrier for that purpose. Advanced ceramic HEPA filters provide an excellent barrier between radioactive material in a nuclear facility and everything downwind. Both university (Cal Poly) student teams did very well. As summarized in this report, they successfully added and upgraded instrumentation and controls to the High Temperature Test Unit (HTTU) for the ceramic filter project. They also succeeded in adding viewing ports, remotely controlled closed circuit television, a flame impingement system and a helium filter gasket leak detection system. Details can be found in Ref. 3 - 6. The HTTU has flexible capabilities and can also be used to test other types of filters or filter components in the future, if so desired. At LLNL, research to improve filter media coating (Fig. 1) is being conducted to maintain filtration efficiency while improving performance (reducing pressure drop). Improvements in the individual filter element are necessary to maintain filtration efficiency while decreasing pressure drop. The path forward for an optimal ceramic HEPA filter meeting DOE’s needs is to improve the filtration media. This task utilized the LLNL/DOE developed innovations along with progress in previous activities to prepare multiple ceramic filter elements and refine the technical details for depositing advanced filtration materials to the ceramic filter to meet desired filter performance. The ceramics filter elements were tested for pressure drop at the required air flow rate using an air flow test system. The filtration efficiency and pressure drop of the ceramic filter elements will be measured as part of the development process.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Three-Body Abrasion Testing Using Lunar Dust Simulants to Evaluate Surface System Materials

Numerous unexpected operational issues relating to the abrasive nature of lunar dust, such as scratched visors and spacesuit pressure seal leaks, were encountered during the Apollo missions. To avoid reoccurrence of these unexpected detrimental equipment problems on future missions to the Moon, a series of two- and three-body abrasion tests were developed and conducted in order to begin rigorously characterizing the effect of lunar dust abrasiveness on candidate surface system materials. Two-body scratch tests were initially performed to examine fundamental interactions of a single particle on a flat surface. These simple and robust tests were used to establish standardized measurement techniques for quantifying controlled volumetric wear. Subsequent efforts described in the paper involved three-body abrasion testing designed to be more representative of actual lunar interactions. For these tests, a new tribotester was developed to expose samples to a variety of industrial abrasives and lunar simulants. The work discussed in this paper describes the three-body hardware setup consisting of a rotating rubber wheel that applies a load on a specimen as a loose abrasive is fed into the system. The test methodology is based on ASTM International (ASTM) B611, except it does not mix water with the abrasive. All tests were run under identical conditions. Abraded material specimens included poly(methyl methacrylate) (PMMA), hardened 1045 steel, 6061-T6 aluminum (Al) and 1018 steel. Abrasives included lunar mare simulant JSC- 1A-F (nominal size distribution), sieved JSC-1A-F (<25 m particle diameter), lunar highland simulant NU-LHT-2M, alumina (average diameter of 50 m used per ASTM G76), and silica (50/70 mesh used per ASTM G65). The measured mass loss from each specimen was converted using standard densities to determine total wear volume in cm3. Abrasion was dominated by the alumina and the simulants were only similar to the silica (i.e., sand) on the softer materials of aluminum and PMMA. The nominal JSC- 1A-F consistently showed more abrasion wear than the sieved version of the simulant. The lunar dust displayed abrasivity to all of the test materials, which are likely to be used in lunar landing equipment. Based on this test experience and pilot results obtained, recommendations are made for systematic abrasion testing of candidate materials intended for use in lunar exploration systems and in other environments with similar dust challenges.

Kobrick, Ryan L.↗

Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches

The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Furthermore, surface event rejection capabilities were tested with two 210 Pb sources producing ~130 beta decays/hr. We found that in ~800 live hours, no events leaked into the 8–115 keV signal region, giving upper limit leakage fraction 1.7 x 10 -5 at 90% C.L., corresponding to<0.6 surface event background in the future 200-kg SuperCDMS SNOLAB experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Greenhouse Gas Laser Imaging Tomography Experiment (GreenLITE): Evaluation of a new method to look at high resolution spatial/temporal distributions of carbon over key sub km sites

Recently a new laser based approach for measuring area with potential for producing 2D estimates of the concentration spatial distribution has been developed through a cooperative agreement with the National Energy and Technology Laboratory of the Department of Energy, Exelis Inc. and AER Inc. The new approach is based on a pair of continuous wave intensity modulated laser absorption spectrometer transceivers, combined with a series of retro reflectors located around the perimeter of the area being monitored. The main goal of this cooperative agreement is monitoring, reporting and verification for ground carbon capture and storage projects. The system was recently tested at the Zero Emission Research and Technology site in Bozeman, MT, with underground leak rates ranging from 0.1 – 0.3 metric ton per day (T/d), as well as a 0.8 T/d surface release. Over 200 hours of data were collected over a rectangular grid 180m x 200m between August 18th and September 9th. In addition, multiple days of in situ data were acquired for the same site, using a Licor gas analyzer systems. Initial comparisons between the laser-based system and the in situ agree very well. The system is designed to operate remotely and transmit the data via a 3G/4G connection along with weather data for the site. An all web-based system ingests the data, populates a database, performs the inversion to ppm CO2 using the Line-by-Line Radiative Transfer Model (LBLRTM), and displays plots and statistics for the retrieved data. We will present an overview of the GreenLITE measurement system, outline the retrieval and reconstruction approach, and discuss results from extensive field testing.

Dobler, Jeremy↗

Testing of Alternative Materials for Advanced Suit Bladders

Several candidate advanced pressure bladder membrane materials have been developed for NASA Johnson Space Center by DSM Biomedical for selective permeability of carbon dioxide and water vapor. These materials were elasthane and two other formulations of thermoplastic polyether polyurethane. Each material was tested in two thicknesses for permeability to carbon dioxide, oxygen and water vapor. Although oxygen leaks through the suit bladder would amount to only about 60 cc/hr in a full size suit, significant amounts of carbon dioxide would not be rejected by the system to justify its use. While the ratio of carbon dioxide to oxygen permeability is about 48 to 1, this is offset by the small partial pressure of carbon dioxide in acceptable breathing atmospheres of the suit. Humidity management remains a possible use of the membranes depending on the degree to which the water permeability is inhibited by cations in the sweat. Tests are underway to explore cation fouling from sweat.

Bue, Grant↗