Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low temperature plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Novel applications for TAZ-8A

Recent needs in the non-aerospace industrial sector have revitalized interest in high performance alloys. TAZ-8A has a combination of properties that makes it unique: a high temperature strength, oxidation resistance, abrasion resistance, and exceptional thermal shock resistance. The major drawback for the utilization of this alloy is the relatively high cost compared with the more common iron base alloys. Reduced material consumption and lower costs are possible by using coatings of TAZ-8A on a low cost substrate. Coatings were applied using plasma spray techniques developed by NASA as well as modified plasma vapor deposition (PVD) techniques.

Riddlebaugh, Stephen M.↗

Thermal barrier coating life and isothermal oxidation of low-pressure plasma-sprayed bond coat alloys

The paper investigates the isothermal oxidation kinetics of Ni-35Cr-6Al-0.95Y, Ni-18Cr-12Al-0.3Y, and Ni-16Cr-6Al-0.3Y low-pressure plasma-sprayed bond coat alloys and examines the effect of these alloys on the thermal barrier coating (TBC) cyclic life. TBC life was examined by cycling substrates coated with the different bond coats and a ZrO2-7 wt pct Y2O3 TBC in an air-rich burner rig flame between 1150 C and room temperature. The oxidation kinetics of the three bond coat alloys was examined by isothermal oxidation of monolithic NJiCrAlY coupons at 1083 C. The Ni-35Cr-6Al-0.95Y alloy exhibits comparatively high isothermal oxidation weight gains and provides the longest TBC life, whereas the Ni-16Cr-6Al-0.3Y alloy had the lowest weight gains and provided the shortest TBC life. The results show that, although bond coat oxidation is known to have a strong detrimental effect on TBC life, it is not the only bond coat factor that determines TBC life.

Brindley, W. J.↗

Ground Tests of High-Voltage Solar Arrays Immersed in a Low Density Plasma

Five different types of solar arrays have been tested in large vacuum chamber. Arc inception voltages, arc rates, and current collections are measured for samples with different coverglass materials and thickness, interconnect designs, and cell sizes. It is shown that the array with wrapthrough interconnects have the highest arc threshold and the lowest current collection. Coverglass design with overhang results in decrease of current collection and increase of arc threshold. Doubling coverglass thickness does not improve measured array parameters. Both arc inception voltage and current collection increase significantly with increasing a sample temperature to 80 C. Sustained discharges are initiated between adjacent cells with potential differences of 40 V for the sample with 300 pm coverglass thickness and 60 V for the sample with 150 urn coverglass thickness.

Vayner, Boris↗

Magnetospheric space plasma investigations

Topics and investigations covering this period of this semiannual report period (August 1994 - January 1995) are as follows: (1) Generalized SemiKinetic (GSK) modeling of the synergistic interaction of transverse heating of ionospheric ions and magnetospheric plasma-driven electric potentials on the auroral plasma transport. Also, presentations of GSK modeling of auroral electron precipitation effects on ionospheric plasma outflows, of ExB effects on such outflow, and on warm plasma thermalization and other effects during refilling with pre-existing warm plasmas; (2) Referees' reports received on the statistical study of the latitudinal distributions of core plasmas along the L = 4.6 field line using DE-1/RIMS data. Other work is concerned in the same field, field-aligned flows and trapped ion distributions; and (3) A short study has been carried out on heating processes in low density flux tubes in the outer plasmasphere. The purpose was to determine whether the high ion temperatures observed in these flux tubes were due to heat sources operating through the thermal electrons or directly to the ions. Other investigations center along the same area of plasmasphere-ionosphere coupling. The empirical techniques and model, the listing of hardware calibrated, and/or tested, and a description of notable meetings attended is included in this report, along with a list of all present publication in submission or accepted and those reference papers that have resulted from this work thus far.

Comfort, Richard H.↗

Quantitative X-ray - UV Line and Continuum Spectroscopy with Application to AGN: State-Specific Hydrogenic Recombination Cooling Coefficients for a Wide Range of Conditions

Recombination cooling, in which a free electron emits light while being captured to an ion, is an important cooling process in photoionized clouds that are optically thick or have low metallicity. State specific rather than total recombination cooling rates are needed since the hydrogen atom tends to become optically thick in high-density regimes such as Active Galactic Nuclei. This paper builds upon previous work to derive the cooling rate over the full temperature range where the process can be a significant contributor in a photoionized plasma. We exploit the fact that the recombination and cooling rates are given by intrinsically similar formulae to express the cooling rate in terms of the closely related radiative recombination rate. We give an especially simple but accurate approximation that works for any high hydrogenic level and can be conveniently employed in large-scale numerical simulations.

LaMothe, J.↗

An Innovative Method for Manufacturing Gamma-TiAl Foil

The manufacture and entrance into service of thin gage gamma-TiAl product has been hampered by the inherent low room temperature ductility of the material. In the present study a new approach was explored for the efficient manufacture of gamma-TiAl foil with improved ductility. The objective was to produce a very clean material (low interstitial content) with a highly refined, homogeneous microstructure placed in a fully lamellar condition. The processing route involved the use of RF plasma spray deposition of pre-alloyed powders, followed by consolidation via vacuum hot pressing and heat treatment. The approach took advantage of a deposition process which included no electrodes, no binders and high cooling rates. Results and discussion of the work performed to date are presented.

Hales, Stephen J.↗

The Abundance Pattern in the Hot ISM of NGC 4472: Insights and Anomalies

Important clues to the chemical and dynamical history of elliptical galaxies are encoded in the abundances of heavy elements in the X-ray emitting plasma. We derive the hot ISM abundance pattern in inner (0.2.3R(sub e)) and outer (2.3.4.6R(sub e)) regions of NGC 4472 from analysis of Suzaku spectra, supported by analysis of co- spatial XMM-Newton spectra. The low background and relatively sharp spectral resolution of the Suzaku XIS detectors, combined with the high luminosity and temperature in NGC 4472, enable us to derive a particularly extensive abundance pattern that encompasses O, Ne, Mg, Al, Si, S, Ar, Ca, Fe, and Ni in both regions. We apply simple chemical evolution models to these data, and conclude that the abundances are best explained by a combination of alpha-element enhanced stellar mass loss and direct injection of Type Ia supernova (SNIa) ejecta. We thus confirm the inference, based on optical data, that the stars in elliptical galaxies have supersolar [alpha/Fe] ratios, but find that that the present-day SNIa rate is approximately 4.6 times lower than the standard value. We find SNIa yield sets that reproduce Ca and Ar, or Ni, but not all three simultaneously. The low abundance of O relative to Ne and Mg implies that standard core collapse nucleosynthesis models overproduce O by approximately 2.

Loewenstein, Michael↗

An Overview of Scientific and Space Weather Results from the Communication/Navigation Outage Forecasting System (C/NOFS) Mission

The Communication/Navigation Outage Forecasting System (C/NOFS) Mission of the Air Force Research Laboratory is described. C/NOFS science objectives may be organized into three categories: (1) to understand physical processes active in the background ionosphere and thermosphere in which plasma instabilities grow; (2) to identify mechanisms that trigger or quench the plasma irregularities responsible for signal degradation; and (3) to determine how the plasma irregularities affect the propagation of electromagnetic waves. The satellite was launched in April, 2008 into a low inclination (13 deg), elliptical (400 x 850 km) orbit. The satellite sensors measure the following parameters in situ: ambient and fluctuating electron densities, AC and DC electric and magnetic fields, ion drifts and large scale ion composition, ion and electron temperatures, and neutral winds. C/NOFS is also equipped with a GPS occultation receiver and a radio beacon. In addition to the satellite sensors, complementary ground-based measurements, theory, and advanced modeling techniques are also important parts of the mission. We report scientific and space weather highlights of the mission after nearly four years in orbit

Pfaff, R.↗

A Bottom-Up Engineered Broadband Optical Nanoabsorber for Radiometry and Energy Harnessing Applications

Optical absorbers based on vertically aligned multi-walled carbon nanotubes (MWCNTs), synthesized using electric-field assisted growth, are described here that show an ultra-low reflectance, 100X lower compared to Au-black from wavelength lamba approximately 350 nm - 2.5 micron. A bi-metallic Co/Ti layer was shown to catalyze a high site density of MWCNTs on metallic substrates and the optical properties of the absorbers were engineered by controlling the bottom-up synthesis conditions using dc plasma-enhanced chemical vapor deposition (PECVD). Reflectance measurements on the MWCNT absorbers after heating them in air to 400deg showed negligible changes in reflectance which was still low, approximately 0.022 % at lamba approximately 2 micron. In contrast, the percolated structure of the reference Au-black samples collapsed completely after heating, causing the optical response to degrade at temperatures as low as 200deg. The high optical absorption efficiency of the MWCNT absorbers, synthesized on metallic substrates, over a broad spectral range, coupled with their thermal ruggedness, suggests they have promise in solar energy harnessing applications, as well as thermal detectors for radiometry.

optical absorbers↗

Radio constraints on coronal models for dMe stars

Radio data are used to test coronal models for dMe stars. Specifically, we show that photospheric magnetic field observations imply that the low corona of a dMe star should be saturated by magnetic fields with an average strength in excess of 1 kG. In such fields the hot component of the corona detected in X-ray observations (temperature of order 2 x 10(exp 7) K) would be optically thick at least up to 15 GHz due to thermal gyroresonance opacity. The resulting emission would easily be detectable by radio observations and should have a radio spectrum rising in the microwave range. We have carried out observations to test this prediction, and in the majority of cases find that the observed fluxes at 15 GHz are too low to be consistent with the assumptions. In the few cases where the stars were detected at 15 GHz, the evidence indicates that the observed emission is nonthermal. These results imply that the hot component of the X-ray-emitting plasma in the corona is not coincident with the strong magnetic fields in the lower corona. Because the hot plasma must still be confined by closed magnetic field lines, it is likely to be restricted to heights of the order of a stellar radius above the photosphere. The results seem to imply a different genesis for the two components of the X-ray-emitting corona of flare stars: the hot component may be cooling flare plasma, while the cooler component (temperature of order 3 x 10(exp 6) K) is associated with a more conventional coronal heating mechanism.

White, S. M.↗

Characterization of Additively Manufacture GRCop-42 and GRCop-84

GRCop-42 (Cu-4 at.% Cr-2 at.% Nb) is a copper-based alloy optimized for high temperature, high thermal conductivity applications such as regenerative cooled rocket engine liners. For this application, it is important to minimize contamination such as trace elements and ceramic inclusions. NASA initiated a series of ten builds by eight companies to assess the repeatability of GRCop-42 between vendors and machines. Utilizing inductively coupled plasma – atomic emission spectroscopy (ICP-AES) and energy dispersive spectroscopy (EDS) techniques allowed for identification of contaminants and quantification of their chemistry. In addition, additive manufacturing (AM) creates a unique microstructure that is often highly textured in the build (Z) direction. Electron backscattered diffraction (EBSD) was used to begin quantifying the degree of crystallographic texture in the copper matrix grains. It was also used to identify the crystallographic form of Cr2Nb, the main strengthening phase, present in the samples. Results showed the presence of ceramic inclusions, highly textured grains, and both the low and high temperature phases of Cr2Nb being present.

copper↗

Antenna admittance determination of electron density.

A circular-aperture flush-mounted antenna for which a theoretical description of the antenna-plasma interaction has been developed was used to obtain a comparison between theoretical and experimental antenna admittance in the presence of ionized boundary layers of low-collision frequency. The antenna was located in a flat-plate model which was in turn located in the expanding-flow environment of a reflected-shock tunnel. The electron-temperature and electron-density distributions in the plate boundary layer at the antenna location were independently measured using voltage-swept thin-wire Langmuir probes for one of the test conditions. The antenna admittance was measured using a four-probe microwave reflectometer and these measured values were found to be in good agreement with those predicted from the theory. Measurements were also performed with another type of circular-aperture antenna which did not satisfy all of the constraints of the theoretical model, although good agreement was obtained between the calculations and the experimental results.

Dunn, M. G.↗

Pioneer Venus Orbiter Electron Temperature Probe

The Orbiter Electron Temperature Probe (OETP) instrumentation and measurement technique has been designed to perform in-situ measurements of electron temperature and electron and ion density in the ionosphere of Venus. Adaptive sweep voltage circuitry continuously tracks the changing electron temperature and spacecraft potential while auto-ranging electrometers adjust their gain in response to the changing plasma density. Control signals used in the instrument to achieve this automatic tracking provide a continuous monitor of the ionospheric parameters without telemetering each volt-ampere curve. Internal data storage permits high data rate sampling of selected raw characteristic curves for low rate transmission to earth. These curves are used to verify or correct the inflight processed data. Sample in orbit measurements are presented to demonstrate instrument performance.

Krehbiel, J. P.↗

Erosion and modification of SO2 ice by ion bombardment of the surface of Io

New measurements on the effect of slow ion bombardment of SO2 ice using Ar(+) in the 15-45 keV range are presented. Total yields for loss of SO2 are given along with the energy spectra of the ejected molecules and molecular fragments and information on the chemical changes induced by the ion bombardment. These data are used to estimate that the direct sputter ejection rate of sulfur into the Jovian plasma is of the order of 10 billion atoms/sq cm/s, that the erosion rate of fresh SO2 deposits due to sputtering is of the order of 0.001 cm/yr, and that a significant and possibly observable column density of SO3 can be produced in an SO2 front only for penetrating ion bombardment. Chemical activity occurs even in rather low-temperature SO2 ice bombardment by ions in the nuclear stopping region, and this activity is likely to increase with increasing temperature.

Johnson, R. E.↗

Plasma-puff initiation of high Coulomb transfer switches

The plasma-puff triggering mechanism based on a hypocycloidal pinch geometry was investigated to determine the optimal operating conditions for an azimuthally uniform surface flashover which initiates plasma-puff under wide ranges of fill gas pressures of Ar, He and N2. The optimal fill gas pressures for the azimuthally uniform plasma-puff were about 120 mTorr less than P(opt) less than 450 Torr for He and N2. For Argon 120 mTorr less than P(opt) less than 5 Torr for argon. The inverse pinch switch was triggered with the plasma-puff and the switching capability under various electrical parameters and working gas pressures of Ar, He and N2 was determined. It was also shown that the azimuthally uniform switching discharges were dependent on the type of fill gas and its fill pressure. A new concept of plasma-focus driven plasma-puff was also discussed in comparison with hypocycloidal pinch plasma-puff triggering. The main discharge of the inverse pinch switch with the plasma-focus driven plasma-puff trigger is found to be more azimuthally uniform than that with the hypocycloidal pinch plasma-puff trigger in a gas pressure region between 80 mTorr and 1 Torr. In order to assess the effects of plasma current density on material erosion of electrodes, emissions from both an inverse-pinch plasma switch (INPIStron) and from a spark gap switch under test were studied with an optical multichannel analyzer (OMA). The color temperature of the argon plasma was approximately 4,000 K which corresponded with the peak continuum emission near 750 nm. There are the strong line emissions of argon in the 650 - 800 nm range and a lack of line emissions of copper and other solid material used in the switch. This indicates that the plasma current density during closing is low and the hot spot or hot filament in the switch is negligible. This result also indicates considerable reduction of line emission with the INPIStron switch over that of a spark-gap switch. However, a strong carbon line emission exists due to vaporization of the plastic insulator used. In order to reduce the vaporization of the insulator, the plexiglass insulating material of INPIStron was replaced with Z-9 material. A comparative study of the INPIStron and a spark gap also reveals that the INPIStron, with a low impedance of Z equals 9 ohms, can transfer a high voltage pulse with a superior pulse-shape fidelity over that of a spark gap with Z equals 100 ohms.

Venable, D. D.↗

Plasma-puff initiation of high Coulomb transfer switches

The plasma-puff triggering mechanism based on a hypocycloidal pinch geometry was investigated to determine the optimal operating conditions for an azimuthally uniform surface flashover which initiates plasma-puff under wide ranges of fill gas pressures of Ar, He and N2. The optimal fill gas pressures for the azimuthally uniform plasma-puff were about 120 mTorr less than P(sub opt) less than 450 Torr for He and N2. For Argon 20 mTorr is less than P(sub opt) is less than 5 Torr. The inverse pinch switch was triggered with the plasma-puff and the switching capability under various electrical parameters and working gas pressures of Ar, He and N2 was determined. It was also shown that the azimuthally uniform switching discharges were dependent on the type of fill gas and its fill pressure. A new concept of plasma-focus driven plasma-puff was also discussed in comparison with hypocycloidal pinch plasma-puff triggering. The main discharge of the inverse pinch switch with the plasma-focus driven plasma-puff trigger is found to be more azimuthally uniform than that with the hypocycloidal pinch plasma-puff trigger in a gas pressure region between 80 mTorr and 1 Torr. In order to assess the effects of plasma current density on material erosion of electrodes, emissions from both an inverse-pinch plasma switch (INPIStron) and from a spark gap switch under test were studied with an optical multichannel analyzer (OMA). The color temperature of the argon plasma was approximately 4,000 K which corresponded with the peak continuum emission near 750 nm. There are the strong line emissions of argon in the 650 - 800 nm range and a lack of line emissions of copper and other solid material used in the switch. This indicates that the plasma current density during closing is low and the hot spot or hot filament in the switch is negligible. This result also indicates considerable reduction of line emission with the INPIStron switch over that of a spark-gap switch. However, a strong carbon line emission exists due to vaporization of the plastic insulator used. In order to reduce the vaporization of the insulator, the plexiglass insulating material of INPIStron was replaced with Z-9 material. A comparative study of the INPIStron and a spark gap also reveals that the INPIStron, with a low impedance of Z = 9 ohms, can transfer a high voltage pulse with a superior pulse-shape fidelity over that of a spark gap with Z = 100 ohms.

Han, Kwang S.↗

A survey of bidirectional greater than or equal to MeV ion flows during the Helios 1 and Helios 2 mission: Observations from the Goddard Space Flight Center instruments

A survey is made of 1.1-2.1 MeV and 3-21 MeV bidirectional ion flows (BIFs) in the solar wind at 0.3-1.0 AU observed by the Goddard Space Flight Center instruments on the Helios 1 and Helios 2 spacecraft during the spacecraft mission in 1974-1984 and 1979-1980, respectively. Some 774 events have been identified Helios 1, and 223 at Helios 2, with mean durations of approximately 2.5 hr at each spacecraft. BIFs were observed for approximately 1%-3% of the observation time during solar minimum conditions in 1975-1977 and for approximately 10%-14% in 1980-1981 around solar maximum. These occurrence rates are similar to those of approximately 1 MeV BIFs observed at the Interplanetary Monitoring Platform 8 and International Sun Earth Explorers (ISEE) 3 spacecraft, and of bidirectional electron heat fluxes at ISEE 3. Solar wind plasma parameters during BIFs were similar to those found generally during the Helios missions, though BIFs have a greater tendency to be associated with cool, low-beta plasma, moderately enhanced and low-variance magnetic fields, both less than 300 km/s and greater than 750 km/s solar wind. Solar wind features associated with the greater than 4 hr duration BIFs include clear plasma shock-driver signatures: approximately 36% of the events; postshock plasma, not associated with shock-driver signatures: approximately 13%; noncompressive density enhancements: approximately 22% (half associated with plasma proton temperature depression); high-speed streams not associated with shocks: approximately 10%; corotating interaction regions: approximately 5%; immediately upstream of shocks: approximately 5%. Around 8% were associated with other solar wind structures, while approximately 4% showed no associated structure. BIFs were present in several of the shock drivers associated with coronal mass ejections (CMEs) observed by the Solwind coronagraph during intervals when Helios 1 was off the limbs of the Sun, showing directly the association of some BIFs with CMEs. some BIFs with CMEs.

Richardson, I. G.↗

Anisotropic shock jump conditions: Theory and observations

The MHD Rankine-Hugoniot (RH) relations for shock waves in a collisionless plasma with bi-Maxwellian distribution functions are considered. While by introducing the pressure anisotropy parameter xi in the RH relations, the number of unknowns -- B, V, n, p and xi (a total of 9) -- becomes one more than the total number of the conservation equations, it is possible to use the observed quantities on both sides of the shock to study the anisotropy changes across the shock. A simple relation for the anisotropy change across the shock is derived as a function of the ratio of magnetic fields m(= B'/B), the shock normal angle theta(sub Bn) and the plasma beta and beta' (primes are downstream values). Since m and theta(sub Bn) can be determined accurately in observation, the reliability of the anisotropy change deduced is mostly dependent on the accuracy of the measurements beta and beta'. We have applied the results to six low-beta quasi-perpendicular (Q perpendicular) laminar bow shock crossings with temperature anisotropy measured in the magnetosheath. In the six test cases, it is found that the predicted pressure anisotropies agree well with those observed in the magnetosheath.

Chao, J. K.↗