Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC MIRRORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

The Mees CCD imaging spectrograph

The Mees CCD (MCCD0 instrument is an imaging spectroscopy device which uses the 25-cm coronagraph telescope and the 3.0-m Coude spectrograph at Mees Solar Observatory on Haleakala, Maui. The instrument works with resolving power up to about 200,000 with significant throughput from 3934 A (Ca II K) to about 10,000 A. A fast guiding active mirror stabilizes the image during observations. A rapidly writing magnetic tape storage system allows observations to be recorded at 256 kbytes/s. Currently, the MCCD is used for imaging spectroscopy of solar flares at 6563 A (H-alpha), and velocity measurements of umbral oscillations; future plans include emission line studies of active region coronae, and photospheric studies of solar oscillations.

Penn, Matthew J.↗

Investigation on the Practicality of Developing Reduced Thermal Models

Throughout the spacecraft design and development process, detailed instrument thermal models are created to simulate their on-orbit behavior and to ensure that they do not exceed any thermal limits. These detailed models, while generating highly accurate predictions, can sometimes lead to long simulation run times, especially when integrated with a spacecraft observatory model. Therefore, reduced models containing less detail are typically produced in tandem with the detailed models so that results may be more readily available, albeit less accurate. In the current study, both reduced and detailed instrument models are integrated with their associated spacecraft bus models to examine the impact of instrument model reduction on run time and accuracy. Preexisting instrument bus thermal model pairs from several projects were used to determine trends between detailed and reduced thermal models; namely, the Mirror Optical Bench (MOB) on the Gravity and Extreme Magnetism Small Explorer (GEMS) spacecraft, Advanced Topography Laser Altimeter System (ATLAS) on the Ice, Cloud, and Elevation Satellite 2 (ICESat-2), and the Neutral Mass Spectrometer (NMS) on the Lunar Atmosphere and Dust Environment Explorer (LADEE). Hot and cold cases were run for each model to capture the behavior of the models at both thermal extremes. It was found that, though decreasing the number of nodes from a detailed to reduced model brought about a reduction in the run-time, a large time savings was not observed, nor was it a linear relationship between the percentage of nodes reduced and time saved. However, significant losses in accuracy were observed with greater model reduction. It was found that while reduced models are useful in decreasing run time, there exists a threshold of reduction where, once exceeded, the loss in accuracy outweighs the benefit from reduced model runtime.

0000↗

Method for separating FEL output beams from long wavelength radiation

A method for improving the output beam quality of a free electron laser (FEL) by reducing the amount of emission at wavelengths longer than the electron pulse length and reducing the amount of edge radiation. A mirror constructed of thermally conductive material and having an aperture therein is placed at an oblique angle with respect to the beam downstream of the bending magnet but before any sensitive use of the FEL beam. The aperture in the mirror is sized to deflect emission longer than the wavelength of the FEL output while having a minor impact on the FEL output beam. A properly sized aperture will enable the FEL radiation, which is coherent and generally at a much shorter wavelength than the bending radiations, to pass through the aperture mirror. The much higher divergence bending radiations will subsequently strike the aperture mirror and be reflected safely out of the way.

42 ENGINEERING↗

Absence of magnetic trapping on closed field lines at Neptune

The large offset of Neptune's magnetic field in an offset tilted dipole (OTD) approximation allows some fraction of magnetospheric field lines to have monotonically increasing field magnitude over their entire length in the magnetosphere. The usual magnetic trapping is impossible on such field lines, meaning that all charged particles on these field lines will precipitate after mirroring at most once. These field lines can be thought of as the part of the global magnetic anomaly where no particles on the corresponding drift shells remain trapped for an entire rotation of the planet. In this paper we examine both the morphology and size of the affected surface area in the OTD2 and O8 magnetic field models. For regions where there are indications that part of the aurora could be due to monotonic field line precipitation we analyze whether these field lines could be sufficiently populated to produce auroral signatures by considering photoelectron production rates and radial diffusion. We conclude that monotonic field line precipitation may contribute to the observed Neptune aurora but does not explain the global phenomenon.

Paranicas, C.↗

Performance Optimization of the Gasdynamic Mirror Propulsion System

Nuclear fusion appears to be a most promising concept for producing extremely high specific impulse rocket engines. Engines such as these would effectively open up the solar system to human exploration and would virtually eliminate launch window restrictions. A preliminary vehicle sizing and mission study was performed based on the conceptual design of a Gasdynamic Mirror (GDM) fusion propulsion system. This study indicated that the potential specific impulse for this engine is approximately 142,000 sec. with about 22,100 N of thrust using a deuterium-tritium fuel cycle. The engine weight inclusive of the power conversion system was optimized around an allowable engine mass of 1500 Mg assuming advanced superconducting magnets and a Field Reversed Configuration (FRC) end plug at the mirrors. The vehicle habitat, lander, and structural weights are based on a NASA Mars mission study which assumes the use of nuclear thermal propulsion' Several manned missions to various planets were analyzed to determine fuel requirements and launch windows. For all fusion propulsion cases studied, the fuel weight remained a minor component of the total system weight regardless of when the missions commenced. In other words, the use of fusion propulsion virtually eliminates all mission window constraints and effectively allows unlimited manned exploration of the entire solar system. It also mitigates the need to have a large space infrastructure which would be required to support the transfer of massive amounts of fuel and supplies to lower a performing spacecraft.

Emrich, William J., Jr.↗

Spinning Hall Probe magnetic compass

In a large range of physics and space experiments, the direction of the magnetic field needs to be determined with an accuracy on the level of one milli radian or better. We have proposed a new type of magnetic compass - a rotation-based one, which provides an alternating signal from the Hall probe proportional to the value of the magnetic field transverse to the axis of rotation. The spinning Hall probe device has been realized. Alignment of the spinning axis for a minimum (zero) value of the signal allows us to find the direction of the magnetic field. The device does not require calibration and is free of any drift problems. The measurement of the rotation axis direction was accomplished by means of a laser and a flat mirror attached to the rotor. The constructed prototype achieved an accuracy for the magnetic field direction in the experiment with the polarized He-3 target on the level of one milli radian.

Wojtsekhowski, Bogdan↗

Supersymmetric defect models and mirror symmetry

We study supersymmetric field theories in three space-time dimensions doped by various configurations of electric charges or magnetic fluxes. These are supersymmetric avatars of impurity models. In the presence of additional sources such configurations are shown to preserve half of the supersymmetries. Mirror symmetry relates the two sets of configurations. We discuss the implications for impurity models in 3d NN = 4 QED with a single charged hypermultiplet (and its mirror, the theory of a free hypermultiplet) as well as 3d NN = 2 QED with one flavor and its dual, a supersymmetric Wilson-Fisher fixed point. Mirror symmetry allows us to find backreacted solutions for arbitrary arrays of defects in the IR limit of NN = 4 QED. Our analysis, complemented with appropriate string theory brane constructions, sheds light on various aspects of mirror symmetry, the map between particles and vortices and the emergence of ground state entropy in QED at finite density.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tunable symmetry breaking in a hexagonal-stacked moiré magnet

Symmetry plays a central role in defining magnetic phases, making tunable symmetry breaking across magnetic transitions highly desirable for discovering non-trivial magnetism. Magnetic moiré superlattices, formed by twisting two-dimensional magnetic crystals, have been theoretically proposed and experimentally explored as platforms for unconventional magnetic states. However, despite recent advances, the ability to tune symmetry breaking in moiré magnetism remains limited, as twisted two-dimensional magnets predominantly inherit the magnetic properties and symmetries of their constituent layers. Here, in this work, we demonstrate a clear evolution of symmetry in hexagonal-stacked twisted double-bilayer CrI 3 as the twist angle increases from 180° to 190°. Although the net magnetization remains zero across this twist-angle range, the magnetic phase breaks only the threefold rotational symmetry at 180°, but it breaks all the rotational, mirror and time-reversal symmetries at intermediate twist angles between 181° and 185°, and all broken symmetries are recovered at 190°. This pronounced symmetry breaking at intermediate twist angles is accompanied by metamagnetic behaviour, evidenced by symmetric double hysteresis loops around zero magnetic field. Together, these results reveal that hexagonal-stacked twisted double-bilayer CrI3 at intermediate twist angles hosts a distinct moiré magnetic phase, featuring periodic in-plane spin textures with broken rotational, mirror and time-reversal symmetries.

Sun, Zeliang (ORCID:0009000770748064)↗

Mirror monochromator

In this SBIR project, Electron Optica, Inc. (EOI) is developing a mirror electron monochromator (MirrorChrom) attachment to new and retrofitted electron microscopes (EMs) for improving the energy resolution of the EM from the characteristic range of 0.2-0.5 eV to the range of 10-50 meV. This improvement will enhance the characterization of materials by imaging and spectroscopy. In particular, the monochromator will refine the energy spectra characterizing materials, as obtained from transmission EMs [TEMs] fitted with electron spectrometers, and it will increase the spatial resolution of the images of materials taken with scanning EMs (SEMs) operated at low voltages. EOI’s MirrorChrom technology utilizes a magnetic prism to simultaneously deflect the electron beam off the axis of the microscope column by 90° and disperse the electrons in proportional to their energies into a module with an electron mirror and a knife-edge. The knife-edge cuts off the tails of the energy distribution to reduce the energy spread of the electrons that are reflected, and subsequently deflected, back into the microscope column. The knife-edge is less prone to contamination, and thereby charging, than the conventional slits used in existing monochromators, which improves the reliability and stability of the module. The overall design of the MirrorChrom exploits the symmetry inherent in reversing the electron trajectory in order to maintain the beam brightness – a parameter that impacts how well the electron beam can be focused downstream onto a sample. During phase I, EOI drafted a set of candidate monochromator architectures and evaluated the trade-offs between energy resolution and beam current to achieve the optimum design for three particular applications with market potential: increasing the spatial resolution of low voltage SEMs, increasing the energy resolution of low voltage TEMs (beam energy of 5-20 keV), and increasing the energy resolution of conventional TEMs (beam energy of 80-120 keV). Specialized software packages that have been developed by MEBS, Ltd. were used to calculate the electron optical properties of the key monochromator components: namely, the magnetic prism, the electron mirror, and the electron lenses. In the final step, these results were folded into a model describing the key electron-optical parameters of the complete monochromator. The simulations reveal that the mirror monochromator can reduce the energy spread of a Schottky electron source, an established electron emitter used widely in EMs, to 10 meV for practical beam current values and that further reduction of the energy spread down to 3 meV is possible for low current applications with a Cold Field Emitter (an electron source with 10x the brightness of a Schottky source). MirrorChroms can be designed and built to attach to different types of TEMs and SEMs, thus making them suitable for enhancing the study of the structure, composition, and bonding states of new materials at the nanoscale to advance material science research in the field of nanotechnology as well as biomedical research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of applications using diaboloid mirrors

The diaboloid is a reflecting surface that converts a spherical wave to a cylindrical wave. This complex surface may find application in new Advanced Light Source bending-magnet beamlines or in other beamlines that now use toroidal optics for astigmatic focusing. Here, the numerical implementation of diaboloid mirrors is described, and the benefit of this mirror in beamlines exploiting diffraction-limited storage rings is studied by ray tracing. The use of diaboloids becomes especially interesting for the new low-emittance storage rings because the reduction of aberration becomes essential for such small sources. Here, the validity of the toroidal and other mirror surfaces approximating the diaboloid, and the effect of the mirror magnification, are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fully Kinetic Large-scale Simulations of the Collisionless Magnetorotational Instability

We present two-dimensional particle-in-cell simulations of the fully kinetic collisionless magnetorotational instability (MRI) in weakly magnetized (high β) pair plasma. The central result of this numerical analysis is the emergence of a self-induced turbulent regime in the saturation state of the collisionless MRI, which can only be captured for large enough simulation domains. One of the underlying mechanisms for the development of this turbulent state is the drift-kink instability (DKI) of the current sheets resulting from the nonlinear evolution of the channel modes. The onset of the DKI can only be observed for simulation domain sizes exceeding several linear MRI wavelengths. The DKI and ensuing magnetic reconnection activate the turbulent motion of the plasma in the late stage of the nonlinear evolution of the MRI. At steady-state, the magnetic energy has an MHD-like spectrum with a slope of k –5/3 for kρ < 1 and k –3 for sub-Larmor scale (kρ > 1). We also examine the role of the collisionless MRI and associated magnetic reconnection in the development of pressure anisotropy. We study the stability of the system due to this pressure anisotropy, observing the development of mirror instability during the early-stage of the MRI. We further discuss the importance of magnetic reconnection for particle acceleration during the turbulence regime. Furthermore, consistent with reconnection studies, we show that at late times the kinetic energy presents a characteristic slope of ϵ –2 in the high-energy region.

79 ASTRONOMY AND ASTROPHYSICS↗

Intercalation-Engineered Out-of-Plane Polarized van der Waals Ferromagnetic Superlattice with Room-Temperature Néel-Type Skyrmions

Superlattices (SLs) based on two-dimensional (2D) van der Waals (vdW) materials, abbreviated as 2D-SLs, have garnered significant attention due to their customizable properties. 2D-SLs can be engineered by mechanical stacking or chemical intercalation to achieve diverse forms of symmetry breaking, resulting in exotic phenomena like the quantum anomalous Hall effect and topological magnetism. Hitherto, broken symmetries in 2D-SLs have been widely produced within lateral planes or three dimensions. However, symmetry breaking along the vertical direction, specifically as an out-of-plane one-dimensional (1D) polarized superlattice, has not yet been achieved. Here, in this paper, we report a so far unseen out-of-plane 1D polarized vdW ferromagnetic superlattice achieved through an approach of two-step intercalation and de-embedding of chromium (Cr)-based 2D vdW magnets. The off-centering polarization of both intrinsic and intercalated Cr atoms in this (1 × 1 × 2) superstructure breaks the mirror symmetry vertically, yielding a Dzyaloshinskii–Moriya interaction (DMI). This results in high-density Néel-type magnetic skyrmions over a broad temperature range. Notably, sub-100 nm Néel-type skyrmions at room temperature (RT) can be achieved by tuning the Cr intercalation ratio, marking the first binary compound RT Néel-type skyrmionic vdW magnet. Our work expands the 2D-SL family with a class of out-of-plane 1D polarized ferromagnetic superlattice with tunable topological magnetism.

1D polarized superlattice↗

Final Technical Report

The nonlinear physics of electron magnetohydrodynamics (EMHD) in plasmas. Time-varying wave magnetic field exceeding the background magnetic field produces highly nonlinear whistler mode since the wave dispersion depends on the total magnetic field. There exists no theory for such whistler modes. The present experimental work is the first one to explore this regime of nonlinear whistlers. A field-reversed configuration has been found which has the same vortex topology as an MHD spheromak, termed a whistler spheromak. Whistler mirrors have compressed and twisted field lines propagating in the whistler mode. Their helicity properties have been studied. Whistler spheromaks and mirrors have different propagation and damping characteristics. Wave collisions have been studied. Head-on collisions of two whistler spheromaks form a stationary field-reversed configuration (FRC) without helicity. When whistler spheromaks are excited the toroidal current flows mainly in the toroidal null line. It is only carried by electrons since ion currents and displacement currents are negligible. A change in the poloidal (axial) magnetic field induces a toroidal electric field which drives the current. Magnetic energy is dissipated and converted into electron kinetic energy. This process is called magnetic reconnection in 2D geometries, which are simplifications for theoretical convenience but rarely occur in nature. A crucial aspect of reconnection is its rate, determined by the electron collisionality. Regular Coulomb collisions can rarely account for the observed reconnection rates. In the present experiments we have also observed fast reconnection and explained it by electron transit time damping in the finite-size null layer. Electrons move faster than a whistler spheromak, hence transit through the toroidal null line where they are freely accelerated. The transit time is essentially the collision time but no particle collisions are required. Strong electron heating and visible light emissions are only observed in whistler spheromaks and FRCs but not in mirrors or asymmetric configurations lacking magnetic null lines. The collisionless electron energization in a toroidal null line usually produces non-Maxwellian distributions. Off the null axis electrons gain more perpendicular than parallel energy. Distributions with T{sub {perpendicular}} > T{sub {parallel}} lead to whistler instabilities which have been observed. A whistler spheromak is a source of high-frequency whistler emissions. These are usually small amplitude whistlers propagating in a complicated background magnetic field. The waves are emitted from a moving source. High frequency whistlers propagate faster than the spheromak, thus partly move ahead of it and partly in the reverse direction. In test wave experiments wave growth opposite to the direction of the hot electron flow has been observed, confirming that Doppler-shifted cyclotron resonance instabilities account for the emission process. Propagating whistler mirrors produce no significant instabilities except when they interact with other fields which exhibit null lines. For example, a whistler mirror has been launched against a stationary FRC, resulting in strong FRC heating and whistler instabilities. In the whistler mirror configuration the antenna near-zone field produces a toroidal null line outside the coil which can also become a source for whistler emissions. Finally, nonlinear EMHD research has been extended to initially unmagnetized plasmas where a new nonlinear skin depth has been discovered. When a small-amplitude oscillating magnetic field is applied to a plasma the field penetration is governed by the skin depth, collisional or collisionless depending on frequency, collision frequency and plasma frequency. However, when the magnetic field increases the electrons become magnetized and the field penetration occurs in the whistler mode if the cyclotron frequency exceeds the oscillating frequency. This phenomenon has been observed. A loop antenna creates a dipole field which is frozen into the plasma for a half cycle and becomes the background field for the wave launched by the next half cycle. The field topology consists of field-reversed dipoles of decreasing strength with distance. The propagation region depends on field amplitude but not on the skin depth. Our research has been published in 13 scientific papers.

43 PARTICLE ACCELERATORS↗

Hofstadter Topology: Noncrystalline Topological Materials at High Flux

he Hofstadter problem is the lattice analog of the quantum Hall effect and is the paradigmatic example of topology induced by an applied magnetic field. Conventionally, the Hofstadter problem involves adding ~10 4 T magnetic fields to a trivial band structure. In this work, we show that when a magnetic field is added to an initially topological band structure, a wealth of possible phases emerges. Remarkably, we find topological phases that cannot be realized in any crystalline insulators. We prove that threading magnetic flux through a Hamiltonian with a nonzero Chern number or mirror Chern number enforces a phase transition at fixed filling and that a 2D Hamiltonian with a nontrivial Kane–Mele invariant can be classified as a 3D topological insulator (TI) or 3D weak TI phase in periodic flux. We then study fragile topology protected by the product of twofold rotation and time reversal and show that there exists a higher order TI phase where corner modes are pumped by flux. We show that a model of twisted bilayer graphene realizes this phase. Our results rely primarily on the magnetic translation group that exists at rational values of the flux. The advent of Moiré lattices renders our work relevant experimentally. Due to the enlarged Moiré unit cell, it is possible for laboratory-strength fields to reach one flux per plaquette and allow access to our proposed Hofstadter topological phase.

36 MATERIALS SCIENCE↗

The use of high temperature superconductors to levitate lunar telescope

The objective of this paper was to assist in the construction of a lunar telescope mirror model by conducting research on composite materials and other lightweight, rigid materials, and by determining how much weight can be levitated by available superconductors. It is believed that with the construction of four magnets suspended over four bulk superconductors (or vice versa), there should be no problems lifting a model mirror and stabilizing it at different positions. It may be necessary to increase the size and quality of the superconductors and/or magnets in order to achieve this.

Brown, Beth A.↗

A contoured gap coaxial plasma gun with injected plasma armature

A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 {mu}g of plasma with density above 10{sup 17} cm{sup -3} to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 {mu}g has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nb$_{3}$Sn 11 T Dipole for the High Luminosity LHC (FNAL). Chapter 8

This chapter describes the design and parameters of the 11 T dipole developed at the Fermi National Accelerator Laboratory (FNAL) in collaboration with the European Organization for Nuclear Research (CERN) for the High Luminosity LHC project, and presents details of the single-aperture and twin-aperture dipole models that were constructed and tested. Magnet test results including magnet quench performance, magnetic measurements, and quench protection studies performed using the dipole mirror and single-aperture and twin-aperture dipole models are summarized and discussed.

43 PARTICLE ACCELERATORS↗