Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Suppression of Runaway Electrons by Resonant Magnetic Perturbations in TEXTOR Disruptions

The generation of runaway electrons in the international fusion experiment ITER disruptions can lead to severe damage at plasma facing components. Massive gas injection might inhibit the generation process, but the amount of gas needed can affect, e.g., vacuum systems. Alternatively, magnetic perturbations can suppress runaway generation by increasing the loss rate. In TEXTOR disruptions runaway losses were enhanced by the application of resonant magnetic perturbations with toroidal mode number n=1 and n=2. The disruptions are initiated by fast injection of about 3x10{sup 21} argon atoms, which leads to a reliable generation of runaway electrons. At sufficiently high perturbation levels a reduction of the runaway current, a shortening of the current plateau, and the suppression of high energetic runaways are observed. These findings indicate the suppression of the runaway avalanche during disruptions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theory of edge localized mode suppression by static resonant magnetic perturbations in the DIII-D tokamak

According to a recent paper [Hu et al ., Phys. Plasmas 26, 120702 (2019)], mode penetration at the top of the pedestal is a necessary and sufficient condition for the suppression of edge localized modes (ELMs) by a resonant magnetic perturbation (RMPs) in an H-mode tokamak discharge. This paper employs asymptotic matching theory to model a particular DIII-D discharge in which ELMs were suppressed by an externally generated, static, n ¼ 2, RMP whose amplitude was modulated at a frequency of 1 Hz. It is demonstrated that the response of the plasma to the applied RMP, in the immediate vicinities of the rational (i.e., resonant) surfaces, is governed by nonlinear, rather than by linear, physics. This is the case because the magnetic island widths associated with driven reconnection exceed the linear layer widths, even in cases where driven reconnection is strongly suppressed by plasma rotation. The natural frequency at a given rational surface (i.e., the helical frequency at which the locally resonant component of the RMP would need to propagate in order to maximize driven reconnection) is found to be offset from the local E B frame in the ion diamagnetic direction. The size of the offset is mostly determined by neoclassical poloidal rotation. Finally, the predictions of a fully nonlinear plasma response model are found to be broadly consistent with the DIII-D experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme terahertz magnon multiplication induced by resonant magnetic pulse pairs

Nonlinear interactions of spin-waves and their quanta, magnons, have emerged as prominent candidates for interference-based technology, ranging from quantum transduction to antiferromagnetic spintronics. Yet magnon multiplication in the terahertz (THz) spectral region represents a major challenge. Intense, resonant magnetic fields from THz pulse-pairs with controllable phases and amplitudes enable high order THz magnon multiplication, distinct from non-resonant nonlinearities such as the high harmonic generation by below-band gap electric fields. Here, we demonstrate exceptionally high-order THz nonlinear magnonics. It manifests as 7th-order spin-wave-mixing and 6th harmonic magnon generation in an antiferromagnetic orthoferrite. We use THz two-dimensional coherent spectroscopy to achieve high-sensitivity detection of nonlinear magnon interactions up to six-magnon quanta in strongly-driven many-magnon correlated states. The high-order magnon multiplication, supported by classical and quantum spin simulations, elucidates the significance of four-fold magnetic anisotropy and Dzyaloshinskii-Moriya symmetry breaking. Moreover, our results shed light on the potential quantum fluctuation properties inherent in nonlinear magnons.

36 MATERIALS SCIENCE↗

Determining hexavalent chromium transport properties in alkaline nuclear waste using nuclear magnetic resonance spectroscopy

This study focuses on the transport properties of hexavalent chromium, specifically the chromate anion, to improve predictive models and environmental remediation strategies for Cr(VI) migration. Using 53 Cr Nuclear Magnetic Resonance (NMR) spectroscopy, the research quantifies chromate in multicomponent electrolytes replicating nuclear waste conditions at the Hanford Site in Washington State. The consistency of the 53 Cr NMR signal integral with chromate concentration, despite varying matrix compositions, establishes it as a reliable concentration indicator. The transport properties of chromate in an alkaline solution were assessed using relaxation-based measurements via saturation recovery and Carr-Purcell-Meiboom-Gill experiments, determining spin-lattice and spin-spin relaxation times. These measurements, combined with the Bloembergen-Purcell-Pound equation, helped estimate the rotational correlation time and the 53 Cr self-diffusion coefficient using Stokes-Einstein-Debye and Stokes-Einstein equations. Direct measurements were obtained through pulsed field gradient stimulated echo 53 Cr NMR spectroscopy. Monte Carlo simulations further estimated uncertainty propagation. The results enhance comprehension of chromate transport and highlight prospects for identifying transport properties of NMR-active nuclei, traditionally considered unreachable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhancing the Optically Detected Magnetic Resonance Signal of Organic Molecular Qubits

In quantum information science and sensing, electron spins are often purified into a specific polarization through an optical-spin interface, a process known as optically detected magnetic resonance (ODMR). Diamond-NV centers and transition metals are both excellent platforms for these so-called color centers, while metal-free molecular analogues are also gaining popularity for their extended polarization lifetimes, milder environmental impacts, and reduced costs. In our earlier attempt at designing such organic high-spin π-diradicals, we proposed to spin-polarize by shelving triplet M S = ±1 populations as singlets. This was recently verified by experiments albeit with low ODMR contrasts of <1% at temperatures above 5 K. In this work, we propose to improve the ODMR signal by moving singlet populations back into the triplet M S = 0 sublevel, designing a true carbon-based molecular analogue to the NV center. Our proposal is based upon transition-orbital and group-theoretical analyses of beyond-nearest-neighbor spin–orbit couplings, which are further confirmed by ab initio calculations of a realistic trityl-based radical dimer. Microkinetic analyses point toward high ODMR contrasts of around 30% under experimentally feasible conditions, a stark improvement from previous works. Finally, in our quest toward ground-state optically addressable molecular spin qubits, we exemplify how our symmetry-based design avoids Zeeman-induced singlet–triplet mixings, setting the scene for realizing electron spin qubit gates.

Group theory↗

TU-AB-BRA-12: Quality Assurance of An Integrated Magnetic Resonance Image Guided Adaptive Radiotherapy Machine Using Cherenkov Imaging

Purpose: To investigate the viability of using Cherenkov imaging as a fast and robust method for quality assurance tests in the presence of a magnetic field, where other instruments can be limited. Methods: Water tank measurements were acquired from a clinically utilized adaptive magnetic resonance image guided radiation therapy (MR-IGRT) machine with three multileaf-collimator equipped 60Co sources. Cherenkov imaging used an intensified charge coupled device (ICCD) camera placed 3.5m from the treatment isocenter, looking down the bore of the 0.35T MRI into a water tank. Images were post-processed to make quantitative comparison between Cherenkov light intensity with both film and treatment planning system predictions, in terms of percent depth dose curves as well as lateral beam profile measurements. A TG-119 commissioning test plan (C4: C-Shape) was imaged in real-time at 6.33 frames per second to investigate the temporal and spatial resolution of the Cherenkov imaging technique. Results: A .33mm/pixel Cherenkov image resolution was achieved across 1024×1024 pixels in this setup. Analysis of the Cherenkov image of a 10.5×10.5cm treatment beam in the water tank successfully measured the beam width at the depth of maximum dose within 1.2% of the film measurement at the same point. The percent depth dose curve for the same beam was on average within 2% of ionization chamber measurements for corresponding depths between 3–100mm. Cherenkov video of the TG-119 test plan provided qualitative agreement with the treatment planning system dose predictions, and a novel temporal verification of the treatment. Conclusions: Cherenkov imaging was successfully used to make QA measurements of percent depth dose curves and cross beam profiles of MRI-IGRT radiotherapy machines after only several seconds of beam-on time and data capture; both curves were extracted from the same data set. Video-rate imaging of a dynamic treatment plan provided new information regarding temporal dose deposition. This study has been funded by NIH grants R21EB17559 and R01CA109558, as well as Norris Cotton Cancer Center Pilot funding.

60 APPLIED LIFE SCIENCES↗

Observing Charge Separation Distance in Organic Donor-Acceptors with Photoinduced Absorption Detected Magnetic Resonance Spectroscopy

The debatable role of charge transfer states in photoinduced charge separation to useful free carriers has been a long-standing controversy in the field of organic solar cells. In this work, varying charge-pair distances are measured in sensitized donor-acceptor thin films using a photoinduced absorption-detected magnetic resonance (PADMR) technique where nearest-neighbor charge transfer states are identified by their strong magnetic dipole-coupling relative to more distant charges. Correlation with the direct measurement of free carriers using time-resolved microwave conductivity has corroborated a distributed-range electron transfer model in which charges generated at longer distances become free carriers, while shorter transfer distances give only bound charge transfer states that cannot separate to generate photocurrent.

charge transfer↗

Defect Characterization of Monocrystalline Silicon Solar Cells with Polysilicon Passivated Contact Using Electrically-Detected Magnetic Resonance (EDMR) Spectroscopy

As the c-Si based solar cell efficiencies are approaching over 26%, it is becoming critical to characterize the low concentrations of the defects – as low as 10^10-10^11 cm-3 (for e.g., iron contamination in high-lifetime Ga-doped wafers3 and n-type wafers), and further reduce them. Also, atomistic level understanding of the mechanisms of the low concentration process-induced-defects and reliability limiting defects (such as light and elevated temperature induced degradation, surface passivation degradation) is needed to design the mitigation strategies. The conventional characterization techniques are limited due to their detection limitations. Some of the techniques based on lifetime spectroscopies can still be used for low concentration characterization however, they are based on estimations and theoretical models and hence, indirect and cannot fully reveal information about the microscopic mechanism of the defects. Thus, we present the application of an ultrasensitive magnetic resonance-based technique for the direct spectroscopic detection of the defects in Si PV - electrically detected magnetic resonance (EDMR). In this work, we aim to focus on establishing a process flow for fabrication of minicells with (miniature replica of the larger-area cells) and setting up the routine for EDMR measurements on them with the EDMR instrumentation capability at NREL. For the EDMR measurements, sample size is limited by the dimensions of sample holder tube (width less than 3.2 mm, active area - 20 mm). Thus, we have designed c-Si based minicells with polysilicon (poly-Si) passivated contacts same as the larger-area cells that we fabricate in our group at NREL. We also modified our minicell process flow for fabricating the textured minicells for preserving the texture during processing and taking care of the laser-ablation edge damage which can significantly affect the performance of such small devices. We have achieved comparable performance on these newly fabricated minicells as that of our 4 cm2 devices with same structure (comparable VOC, JSC, FF). We also conducted EDMR measurements on the minicells and observed a distinct EDMR signal at g-value ~2.005 at temperatures 30K and above, as shown in Fig. 2. We associate this signal to the presence of silicon dangling bonds based on the g-value. We also observed an EDMR signal at g-value ~1.998 at temperature ~5K. The origin of this signal is still being investigated. Thus, we show the proof of concept of minicells and EDMR measurements with which we now aim to study some of the unknown defects in silicon solar cell devices.

EDMR↗

Advanced Imaging of the Left Atrium with Cardiac Magnetic Resonance: A Review of Current and Emerging Methods and Clinical Applications

Purpose of Review: The thin wall of the left atrium (LA) is difficult to visualize. The high spatial and temporal resolution of cardiac magnetic resonance (CMR) allows for the most accurate assessment of left atrial structure, function, and tissue characterization. This review will describe emerging methods used to image the LA with CMR, and will discuss associated clinical applications. Recent Findings: LA function can now be described in a dynamic fashion with feature-tracking algorithms. Novel methods have been created to augment visualization of late gadolinium enhancement (LGE) in the LA, and left atrial fibrosis can be further quantified with T1 mapping algorithms. The advancement in how we image the LA with CMR has implications in atrial fibrillation (AF) and cardiomyopathic processes. Summary: A nuanced understanding of left atrial pathology is emerging with the rapid advancement of CMR technology, which has implications in the risk stratification and treatment of several cardiovascular disease states.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Susceptibility Contrast Magnetic Resonance Imaging Determination of Fractional Tumor Blood Volume: A Noninvasive Imaging Biomarker of Response to the Vascular Disrupting Agent ZD6126

Purpose: To assess tumor fractional blood volume ({xi}), determined in vivo by susceptibility contrast magnetic resonance imaging (MRI) as a noninvasive imaging biomarker of tumor response to the vascular disrupting agent ZD6126. Methods and Materials: The transverse MRI relaxation rate R{sub 2}* of rat GH3 prolactinomas was quantified prior to and following injection of 2.5 mgFe/kg feruglose, an ultrasmall superparamagnetic iron oxide intravascular contrast agent, and {xi} (%) was determined from the change in R{sub 2}*. The rats were then treated with either saline or 50 mg/kg ZD6126, and {xi} measured again 24 hours later. Following posttreatment MRI, Hoechst 33342 (15 mg/kg) was administered to the rats and histological correlates from composite images of tumor perfusion and necrosis sought. Results: Irrespective of treatment, tumor volume significantly increased over 24 hours. Saline-treated tumors showed no statistically significant change in {xi}, whereas a significant (p = 0.002) 70% reduction in {xi} of the ZD6126-treated cohort was determined. Hoechst 33342 uptake was associated with viable tumor tissue and was significantly (p = 0.004) reduced and restricted to the rim of the ZD6126-treated tumors. A significant positive correlation between posttreatment {xi} and Hoechst 33342 uptake was obtained (r = 0.83, p = 0.002), providing validation of the MRI-derived measurements of fractional tumor blood volume. Conclusions: These data clearly highlight the potential of susceptibility contrast MRI with ultrasmall superparamagnetic iron oxide contrast agents to provide quantitative imaging biomarkers of fractional tumor blood volume at high spatial resolution to assess tumor vascular status and response to vascular disrupting agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Bladder Motion for Clinical Radiotherapy Practice Using Cine-Magnetic Resonance Imaging

Purpose: Organ motion is recognized as the principal source of inaccuracy in bladder radiotherapy (RT), but there is currently little information on intrafraction bladder motion. Methods and Materials: We used cine-magnetic resonance imaging (cine-MRI) to study bladder motion relevant to intrafraction RT delivery. On two occasions, a 28 minute cine-MRI sequence was acquired from 10 bladder cancer patients and 5 control participants immediately after bladder emptying, after abstinence from drinking for the preceding hour. From the resulting cine sequences, bladder motion was subjectively assessed. To quantify bladder motion, the bladder was contoured in imaging volume sets at 0, 14, and 28 min to measure changes to bladder volumes, wall displacements, and center of gravity (COG) over time. Results: The dominant source of bladder motion during imaging was bladder filling (up to 101% volume increase); rectal and small bowel movements were transient, with minimal impact. Bladder volume changes were similar for all participants. However for bladder cancer patients, wall displacements were larger (up to 58 mm), less symmetrical, and more variable compared with nondiseased control bladders. Conclusions: Significant and individualized intrafraction bladder wall displacements may occur during bladder RT delivery. This important source of inaccuracy should be incorporated into treatment planning and verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Test of the ITER-like resonant magnetic perturbation configurations for edge-localized mode crash suppression on KSTAR

KSTAR has demonstrated divertor heat flux broadening during edge-localized-mode (ELM)-crash-suppression using ITER-like 3-row resonant magnetic perturbation (RMP) for the first time. To address a couple of critical issues in ITER RMP, robust ELM-crash-suppression methodology has been explored at low q95 and established in KSTAR using low-nRMPs. Taking full advantage of the ITER-like 3-row in-vessel control coils (IVCC) in KSTAR, a set of intentionally misaligned RMP configurations (IMC) was tested to investigate whether or not IMC could be compatible with ELM-crash-suppression, while minimizing electromagnetic loads on RMP coils. As a result, the ITER-like 3-row IMCs were found not only to have been compatible with the ELM-crash-suppression, but also to have broadened the divertor heat fluxesin the vicinity of the outer strike point. In comparison, the 2-row RMPs have rarely affected the near scrape-off-layer (SOL) heat flux despite slightly broadened profile change in the far-SOL. Since the divertor heat flux broadening reflects the dispersal of the peaked near-SOL heat flux, the experimental outcome is quite favorable to the ITER choice of 3-rows, instead of 2-rows. Nonetheless, since the IMC-driven broadening observed in the attached plasmas in KSTAR might appear substantially different in the partially detached plasmas in ITER, additional investigation has been conducted to see if RMP-driven, ELM-crash-suppression could be compatible with detached plasmas. Although no detached plasmas have been identified with ELM-crash-suppression yet, significantly reduced divertor heat flux was confirmed in high density, ELM-crash-suppressed plasmas at q 95 =3.4using n=2 RMPs. These new findings elevate the confidence level about the ITER RMP system, while the remaining uncertainties need to be further clarified using the 3-row IVCCs in KSTAR. As long as mode-locking percussion is minimized along with a quick recovery of wall conditions, the access to the targeted q95(~ 3) for ITER is foreseen to be feasible in KSTAR

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimation of Error in Maximal Intensity Projection-Based Internal Target Volume of Lung Tumors: A Simulation and Comparison Study Using Dynamic Magnetic Resonance Imaging

Purpose: To evaluate the error in four-dimensional computed tomography (4D-CT) maximal intensity projection (MIP)-based lung tumor internal target volume determination using a simulation method based on dynamic magnetic resonance imaging (dMRI). Methods and Materials: Eight healthy volunteers and six lung tumor patients underwent a 5-min MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to generate re-sorted dMRI using 4D-CT acquisition methods (RedCAM) by segmenting and rebinning the MRI scans. The maximal intensity projection images were generated from RedCAM and dMRI, and the errors in the MIP-based internal target area (ITA) from RedCAM ({epsilon}), compared with those from dMRI, were determined and correlated with the subjects' respiratory variability ({nu}). Results: Maximal intensity projection-based ITAs from RedCAM were comparatively smaller than those from dMRI in both phantom studies ({epsilon} = -21.64% {+-} 8.23%) and lung tumor patient studies ({epsilon} = -20.31% {+-} 11.36%). The errors in MIP-based ITA from RedCAM correlated linearly ({epsilon} = -5.13{nu} - 6.71, r{sup 2} = 0.76) with the subjects' respiratory variability. Conclusions: Because of the low temporal resolution and retrospective re-sorting, 4D-CT might not accurately depict the excursion of a moving tumor. Using a 4D-CT MIP image to define the internal target volume might therefore cause underdosing and an increased risk of subsequent treatment failure. Patient-specific respiratory variability might also be a useful predictor of the 4D-CT-induced error in MIP-based internal target volume determination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modes of magnetic resonance of S=1 dimer chain compound NTENP

The spin dynamics of a quasi-one-dimensional S = 1 bond alternating spin-gap antiferromagnet Ni(C{sub 9}H{sub 24}N{sub 4})NO{sub 2}(ClO{sub 4}) (abbreviated as NTENP) is studied by means of electron-spin-resonance (ESR) technique. Five modes of ESR transitions are observed and identified: transitions between singlet ground state and excited triplet states, three modes of transitions between spin sublevels of collective triplet states and antiferromagnetic resonance absorption in the field-induced antiferromagnetically ordered phase. Singlet-triplet and intratriplet modes demonstrate a doublet structure which is due to two maxima in the density of magnon states in the low-frequency range. A joint analysis of the observed spectra and other experimental results allows to test the applicability of the fermionic and bosonic models. We conclude that the fermionic approach is more appropriate for the particular case of NTENP.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic Field Sensing via Optically Detected Magnetic Resonance and Spin Relaxometry Using Nitrogen Vacancies in Nanodiamonds

Quantum sensing is broadly defined as the use of quantum materials, quantum coherence, and/or quantum entanglement to measure physical quantities and/or to enhance the sensitivity of classical analytical measurements. Certain materials exhibit interesting quantum properties that have the potential to be utilized in quantum sensing applications. One such quantum property is electronic spin, which is utilized in this work. Here, we built a custom apparatus capable of conducting both optically detected magnetic resonance (ODMR) and spin relaxometry. The quantum material investigated was an ensemble of nitrogen vacancies (NV) in nanodiamonds. We have characterized the system and measured ODMR spectra for different strengths of the applied DC magnetic field and clearly observed the expected splitting of the resonances due to Zeeman splitting. We also have measured the spin relaxation times for two different powers of the applied AC magnetic field. The lower power dataset exhibited expected exponential temporal dependence of the relaxation of a modified spin state, whereas the higher power dataset exhibited stretched exponential dependence of the evolution of the modified spin state, indicating the presence of high-power phenomena that emerge that retard the relaxation of the spin state.

Lander, Gary↗

Magnetic Field Sensing via Optically Detected Magnetic Resonance and Spin Relaxometry Using Nitrogen Vacancies in Nanodiamonds

Quantum sensing is broadly defined as the use of quantum materials, quantum coherence, and/or quantum entanglement to measure physical quantities and/or to enhance the sensitivity of classical analytical measurements. Certain materials exhibit interesting quantum properties that have the potential to be utilized in quantum sensing applications. One such quantum property is electronic spin, which is utilized in this work. Here, we built a custom apparatus capable of conducting both optically detected magnetic resonance (ODMR) and spin relaxometry. The quantum material investigated was an ensemble of nitrogen vacancies (NV) in nanodiamonds. We have characterized the system and measured ODMR spectra for different strengths of the applied DC magnetic field and clearly observed the expected splitting of the resonances due to Zeeman splitting. We also have measured the spin relaxation times for two different powers of the applied AC magnetic field. The lower power dataset exhibited expected exponential temporal dependence of the relaxation of a modified spin state, whereas the higher power dataset exhibited stretched exponential dependence of the modified spin state, indicating the presence of high-power phenomena that emerge that retard the relaxation of the spin state.

Lander, Gary↗

Predicting variation in subject thermal response during transcranial magnetic resonance guided focused ultrasound surgery: Comparison in seventeen subject datasets

Purpose: In transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) treatments, the acoustic and spatial heterogeneity of the skull cause reflection, absorption, and scattering of the acoustic beams. These effects depend on skull-specific parameters and can lead to patient-specific thermal responses to the same transducer power. In this work, the authors develop a simulation tool to help predict these different experimental responses using 3D heterogeneous tissue models based on the subject CT images. The authors then validate and compare the predicted skull efficiencies to an experimental metric based on the subject thermal responses during tcMRgFUS treatments in a dataset of seventeen human subjects. Methods: Seventeen human head CT scans were used to create tissue acoustic models, simulating the effects of reflection, absorption, and scattering of the acoustic beam as it propagates through a heterogeneous skull. The hybrid angular spectrum technique was used to model the acoustic beam propagation of the InSightec ExAblate 4000 head transducer for each subject, yielding maps of the specific absorption rate (SAR). The simulation assumed the transducer was geometrically focused to the thalamus of each subject, and the focal SAR at the target was used as a measure of the simulated skull efficiency. Experimental skull efficiency for each subject was calculated using the thermal temperature maps from the tcMRgFUS treatments. Axial temperature images (with no artifacts) were reconstructed with a single baseline, corrected using a referenceless algorithm. The experimental skull efficiency was calculated by dividing the reconstructed temperature rise 8.8 s after sonication by the applied acoustic power. Results: The simulated skull efficiency using individual-specific heterogeneous models predicts well (R{sup 2} = 0.84) the experimental energy efficiency. Conclusions: This paper presents a simulation model to predict the variation in thermal responses measured in clinical ctMRGFYS treatments while being computationally feasible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗