Performance of a Low Activity Beta-Sensitive SR{sup 90} Water Monitor for Fukushima

There are large volumes of contaminated water from the stabilization efforts at the damaged Fukushima Nuclear Power Plants. This water is being processed to remove radioactivity for eventual release to the environment. An on-line continuously operating system to confirm that the clean-up system is working properly, and to provide prompt feedback of the results is required by the system operator. While gamma emitting nuclides allow for the straight forward approach of gamma spectroscopy to identify and quantify radioactivity in water, pure beta emitting nuclides such as Sr{sup 90} pose a challenging problem. The relatively short range of beta radiation in water requires optimization of the measurement geometry in terms of the source-detector distance and source-detector interface while retaining a background sensitivity low enough to meet the Minimum Detectable Concentration (MDC) of 10 Bq/kg in 180 minutes. This issue is complicated by the continuum nature of the beta spectrum which does not allow for simple nuclide identification. The use of the Monte-Carlo code MCNP to estimate system performance before prototyping vastly increases the success of the end product. Various parameters such as detector size and thickness, water chamber size, water chamber construction materials were evaluated to help choose the optimum geometry. The final design was a system consisting of two large-area (16 x 35 cm) and thin (0.15 mm) plastic scintillators placed very close to a sealed a water chamber. The size of the chamber was optimized to obtain the maximum efficiency for the nuclide being measured (Sr/Y{sup 90}) but to minimize the efficiency for possible interferences (Ru/Rh{sup 106}, Cs{sup 137}). A thin carbon fiber window was selected with adequate material and thickness to contain the water under pressure, but also thin enough (0.5 mm) to allow enough beta radiation to pass through to the active detector volume. The entire measurement geometry is then housed in a thick lead shield to reduce contributions from external sources to an acceptable level. Data acquisition is accomplished through customized application-specific software that allows for long counting times to attain a low MDC, but also simultaneously provides alarms on short averaging times to achieve a fast response to sudden changes in activity concentration. Multiple monitors are then linked to supervisory software where real time data and alarms are available for analysis in remote locations. The system also allows for remote operation of the unit; check sources, background checks, systems settings and more may be accessed remotely. Testing of the production devices has shown that we can achieve the 10 Bk/kg MDC requirement for Sr{sup 90} in equilibrium with Y{sup 90} with a count time of approximately 20 minutes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Spectral Band Adjustment Factors for Cross-Calibration of Visible Imagers

The CERES EBAF dataset provides TOA SW and LW fluxes for long-term monitoring of the Earth’s energy balance and to validate climate models. The EBAF products, based on the Terra and Aqua CERES instrument observed radiances, rely on coincident measurements from the onboard MODIS imagers to determine cloud properties that are used in the angular distribution model scene selection required to convert the CERES observed radiances into flux values. Once the Terra and Aqua orbits start drifting outside of their 15-minute window, the CERES project will rely solely on the NOAA-20 CERES observations. A seamless transition of fluxes and clouds can only occur if the analogous MODIS and VIIRS channels are properly inter-calibrated. The visible band (0.65 µm) in MODIS (band 1) and VIIRS (M5 or I1) is critical for retrieving the cloud mask and optical depth. The spectral response functions (SRF) of these bands differ noticeably and will require scene dependent spectral band adjustment factors (SBAF) for proper radiometric scaling between them. Fortunately, the VIIRS I1 and M5 bands are calibrated using the same solar diffuser as a reference, which implies that band reflectance differences must be due to the spectral disparity. The coincident I1 and M5 TOA reflectance measurements provide the optimal opportunity to validate SBAFs over many surface and cloud conditions. The CERES project maintains SCIAMACHY, GOME-2, Hyperion, and radiative transfer model-based scene-stratified hyper-spectral reflectance measurements that can be convolved with sensor pair SRFs to compute the corresponding SBAF. This study will evaluate the SCIAMACHY, GOME-2, Hyperion, and RTM based SBAFs over tropical ocean targets used in SNO inter-calibration of MODIS and VIIRS, including clear-sky ocean, deep convective clouds (DCC), and liquid cloud targets in terms of their applicability to absolute intercomparison of visible imagers. The large SCIAMACHY and GOME-2 footprints and the lack of Hyperion cloudy scenes will impact the resulting SBAFs and necessitates the need for future CLARREO hyper-spectral reflectances to decrease SBAF uncertainties Preliminary results indicate that the SCIAMACHY and GOME-2 based SBAFs for the VIIRS I1 and M5 band pairs may differ by 1.5% for some ATO scene types. Because most of the modern GEOs visible band SRFs encompass the VIIRS I1 band SRF, these evaluations are critical to ensure that the MODIS, VIIRS, and GEO clouds and fluxes are consistent. SBAFs for Libya-4, Dome-C and other Earth invariant target will also be evaluated.

D. R. Doelling↗

Measurement of the Branching Ratio of the charmless decay B s → φφ at CDFII

We present a study of the charmless B s → φφ decay performed with the CDFII detector at the Fermilab Tevatron Collider. Charmless B0 decays currently can be studied only at the Tevatron and represent a field still to be fully explored that offers additional ways to test our present theoretical understanding. The B s → φφ belongs to a particular class of these decays: the B s meson decays into a pair of vector particle and the fi al state is self- conjugate. It can be used to measure the B s decay width difference (ΓΔs), to improve our understanding about the Cabibbo Kobayashi Maskawa matrix, and to perform tests of decay polarization predictions. The B s → φφ decay proceeds through a b → sss transition and in the Standard Model the dominant process is the b → s “penguin” diagram. The same penguin amplitude is involved in several processes which have shown several discrepancies with the Standard Model predictions, raising considerable attention on the theoretical side and new physics interpretations have been considered to explain the experimental data. To shed light on this experimental and theoretical rather complex scenario, new and more precise measurements are clearly needed in as many interesting channels as possible. The study of B s → φφ channel is an important player in this experimental effort. The B s → φφ decay has been observed for the first time by CDF in 2005 [1] in a data sample of 180 pb -1 ; eight events have been seen and a first measurement of the Branching Ratio (BR) has been performed. In this thesis we present an update of this measurement with an integrated luminosity of 2.9fb -1 . An improvement of a factor 5 compared to the previous Branching Ratio measurement is achieved. In Chap.2 a short introduction on the Standard Model with special emphasis on the electroweak sector is presented. In Chap.3 the Fermilab accelerator complex and the CDFII detector is described. The trigger strategy to select events relevant to B physics is explained in some detail. In Chap.4 we present the data sample used for this analysis and some informations concerning the offline reconstruction program. In Chap.5 the Monte Carlo program and its validation procedure are explained. In Chap.6 the strategy of the Branching Ratio measurement and the optimization procedure used to define the analysis selection criteria both for the B s → φφ and the B s → J/ψφ decays are presented. In Chap.7 all the steps needed to perform the measurement of the BR are reported. Signal yields of the B s → φφ and the B s → J/ψφ decays are presented. The trigger and selection efficiencies and the muon efficiency are evaluated. The ratio of the BR(B s → φφ) to the BR(B s → J/ψφ) is measured and is used to compute the Branching Ratio of B s → φφ. The systematic errors on the BR are estimated. In Chap.8 we present the summary of our results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Air Conditioning Systems Fault Detection and Diagnosis-Based Sensing and Data-Driven Approaches

The air conditioning (AC) system is the primary building end-use contributor to the peak demand for energy. The energy consumed by this system has grown as fast as it has in the last few decades, not only in the residential section but also in the industry and transport sectors. Therefore, to combat energy crises, urgent actions on energy efficiency should be taken to support energy security. Consequently, the faults in AC system components increase energy consumption due to the degradation of the system’s performance and the losses in the energy conversion procedure. In this work, AC system fault detection and diagnosis (FDD) methods are investigated to propose analytic tools to identify faults and provide solutions to those problems. The analysis of existing work shows that data-driven approaches are more accurate for both soft and hard fault detection and diagnosis in AC systems. Therefore, the proposed methods are not accurate for simultaneous fault detection, while in some works, authors tested the method with several faults separately without investigating scenarios that combine more than one fault. Moreover, this study shows that integrating data-driven approaches requires deploying an optimal sensing and measurement architecture that can detect a maximum number of faults with minimally deployed sensors. The new sensing, information, and communication technologies are discussed for their integration in AC system monitoring in order to optimize system operation and detect faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WE-G-204-03: Photon-Counting Hexagonal Pixel Array CdTe Detector: Optimal Resampling to Square Pixels

Purpose: Detectors with hexagonal pixels require resampling to square pixels for distortion-free display of acquired images. In this work, the presampling modulation transfer function (MTF) of a hexagonal pixel array photon-counting CdTe detector for region-of-interest fluoroscopy was measured and the optimal square pixel size for resampling was determined. Methods: A 0.65mm thick CdTe Schottky sensor capable of concurrently acquiring up to 3 energy-windowed images was operated in a single energy-window mode to include ≥10 KeV photons. The detector had hexagonal pixels with apothem of 30 microns resulting in pixel spacing of 60 and 51.96 microns along the two orthogonal directions. Images of a tungsten edge test device acquired under IEC RQA5 conditions were double Hough transformed to identify the edge and numerically differentiated. The presampling MTF was determined from the finely sampled line spread function that accounted for the hexagonal sampling. The optimal square pixel size was determined in two ways; the square pixel size for which the aperture function evaluated at the Nyquist frequencies along the two orthogonal directions matched that from the hexagonal pixel aperture functions, and the square pixel size for which the mean absolute difference between the square and hexagonal aperture functions was minimized over all frequencies up to the Nyquist limit. Results: Evaluation of the aperture functions over the entire frequency range resulted in square pixel size of 53 microns with less than 2% difference from the hexagonal pixel. Evaluation of the aperture functions at Nyquist frequencies alone resulted in 54 microns square pixels. For the photon-counting CdTe detector and after resampling to 53 microns square pixels using quadratic interpolation, the presampling MTF at Nyquist frequency of 9.434 cycles/mm along the two directions were 0.501 and 0.507. Conclusion: Hexagonal pixel array photon-counting CdTe detector after resampling to square pixels provides high-resolution imaging suitable for fluoroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Measure Approximation for Distributionally Robust PDE-Constrained Optimization Problems

In numerous applications, scientists and engineers acquire varied forms of data that partially characterize the inputs to an underlying physical system. This data is then used to inform decisions such as controls and designs. Consequently, it is critical that the resulting control or design is robust to the inherent uncertainties associated with the unknown probabilistic characterization of the model inputs. Here in this work, we consider optimal control and design problems constrained by partial differential equations with uncertain inputs. We do not assume a known probabilistic model for the inputs, but rather we formulate the problem as a distributionally robust optimization problem where the outer minimization problem determines the control or design, while the inner maximization problem determines the worst-case probability measure that matches desired characteristics of the data. We analyze the inner maximization problem in the space of measures and introduce a novel measure approximation technique, based on the approximation of continuous functions, to discretize the unknown probability measure. Finally, we prove consistency of our approximated min-max problem and conclude with numerical results.

54 ENVIRONMENTAL SCIENCES↗

Measurement placement in electric power transmission and distribution grids: Review of concepts, methods, and research needs

Sensing and measurement systems are quintessential to the safe and reliable operation of electric power grids. Their strategic placement is of ultimate importance because it is not economically viable to install measurement systems on every node and branch of a power grid, though they need to be monitored. An overwhelming number of strategies have been developed to meet oftentimes multiple conflicting objectives. The prime challenge in formulating the problem lies in developing a heuristic or an optimisation model that, though mathematically tractable and constrained in cost, leads to trustworthy technical solutions. Further, large-scale, long-term deployments pose additional challenges because the boundary conditions change as technologies evolve. For instance, the advent of new technologies in sensing and measurement, as well as in communications and networking, might impact the cost and performance of available solutions and shift initially set conditions. Also, the placement strategies developed for transmission grids might not be suitable for distribution grids, and vice versa, because of unique characteristics; therefore, the strategies need to be flexible, to a certain extent, because no two power grids are alike. Despite the extensive literature on the present topic, the focus of published works tends to be on a specific subject, such as the optimal placement of measurements to ensure observability in transmission grids. There is a dearth of work providing a comprehensive picture for developing optimal placement strategies. Because of the ongoing efforts on the modernisation of electric power grids, there is a need to consolidate the status quo while exposing its limitations to inform policymakers, industry stakeholders, and researchers on the research-and-development needs to push the boundaries for innovation. Accordingly, this paper first reviews the state-of-the-art considering both transmission and distribution grids. Then, it consolidates the key factors to be considered in the problem formulation. Finally, it provides a set of perspectives on the measurement placement problem, and it concludes with future research directions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structure, Morphology, and Photovoltaic Implications of Halide Alloying in Lead-Free Cs 3 Sb 2 Cl x I 9-x 2D-Layered Perovskites

Compositional tuning has been a major driving force behind the excellent optoelectronic properties observed in typical Pb-based perovskites. For lead-free perovskite derivatives, a challenge to understanding the connection between compositional tuning and intrinsic optoelectronic properties, hence a barrier towards boosting their performance, comes from the fact that multiple crystalline substructures can form based on composition, film processing, or both. Especially with lower dimensional (0D, 1D, 2D) substructures, the particular polymorph present in the film can be a greater determinant of optoelectronic properties than the composition itself. Herein, we report a simple method to alloy the halide site in all-inorganic lead-free Cs 3 Sb 2 I 9 films while maintaining a consistent 2D-layered substructure, as a means to independently study the photovoltaic implications of halide substitution. We use a broad suite of spectroscopy and device measurements to identify an optimal stoichiometric substitution of chloride for iodide (~ 8 mol%, measured) that balances both intrinsic and bulk optoelectronic properties to achieve a top power conversion efficiency of 2.2%. This work underscores the importance of controlling substructure while investigating the impacts of compositional tuning for the development of lead-free perovskites, and more broadly validates the approach towards realizing lead-free alternative perovskite solar technologies.

14 SOLAR ENERGY↗

Agreement Between Local and Global Measurements of the London Penetration Depth

Recent measurements of the superconducting penetration depth in Ba(Fe{sub 1-x}Co{sub x}){sub 2}As{sub 2} appeared to disagree on the magnitude and curvature of {delta}{lambda}{sub ab}(T), even near optimal doping. These measurements were carried out on different samples grown by different groups. To understand the discrepancy, we use scanning SQUID susceptometry and a tunnel diode resonator to measure the penetration depth in a single sample. The penetration depth observed by the two techniques is identical with no adjustments. We conclude that any discrepancies arise from differences between samples, either in growth or crystal preparation.

99 GENERAL AND MISCELLANEOUS↗

In-Situ Spatial Mapping of Hydrogen in Yttrium Hydrides at LANSCE (FY23 Version, Rev. 1)

This report summarizes the development of neutron imaging capabilities and experimental activities performed at the Los Alamos Neutron Science Center (LANSCE) with the main goal of measuring temperature-driven hydrogen diffusion within bulk-yttrium hydride (YH x ) materials. Yttrium hydride is the leading candidate to serve as a solid neutron moderator in microreactor cores, owing to its high density of hydrogen atoms as well as its superior thermal stability compared to all other metal hydrides. The experimental results and technique developments reported herein support the U.S. Department of Energy Office of Nuclear Energy’s (DOE-NE) Microreactor Program under Technology Maturation. In particular, it addresses the critical need to experimentally validate and verify hydrogen-diffusion models of metal hydrides used in high-temperature microreactor designs by means of high-spatial-resolution neutron imaging. These capabilities were designed to apply large temperature gradients across centimeter-sized YH x pellets to simulate conditions faced in the microreactor environment. In principle, neutron imaging, combined with in-situ sample heating, enables near real-time tracking of hydrogen diffusion in YH x on the sub-millimeter scale. In this report, an overview of neutron imaging methodology and technologies are given in the context of recent spatial measures of hydrogen concentrations in similar metal hydrides. Additionally, the commissioning and operation of a custom-built compact dual-zone furnace is given along with details on three in-situ heating measurements of YH x performed over the 2020 to 2022 LANSCE operation cycles. The aims of these experiments ranged from furnace commissioning, determining sample quality, i.e., hydrogen uniformity via neutron computed tomography, and studying the effects of applied temperature-gradients on YH x pellets. Analyses and results from these neutron imaging measurements are given along with outlooks and guidelines for optimal future hydrogen diffusion measurements. Our conclusions are as follows. Image analyses indicate that centimeter-sized yttrium hydride cylindrical pellets exhibit uniform, whole-body hydrogen desorption and absorption without clear temperature dependence as reflected in the image attenuation at the opposing ends of each sample. This suggests that despite the large magnitude in temperature gradients applied by the furnace heating elements, the sample equilibrates to an unknown intermediate temperature. The origin of this result is likely the combination of short sample length (∼1cm) and use of a TZM can for containment where the latter created a thermal short across the sample. Nevertheless, the results from the most recent measurements indicate that neither significant concentration gradients of hydrogen were formed in centimeter-sized samples through the entire temperature range (25 °C to 950 °C) nor any formed due to temperature gradients on the order of 50 °C/cm up to 700 °C/cm. Furthermore, images from the FY2021 and FY2022 measurements indicate that samples of YH x , fabricated from either the direct hydride or powder metallurgy methods, are highly uniform in their hydrogen concentration to within the measurements’ spatial resolutions. The following questions arise from these latest results: 1) What is the intermediate temperature of the pellets in the TZM cans? 2) How quickly does the temperature equilibrate within the sample? and, 3) Do the observed changes in image attenuation follow known pressure-composition-temperature relations of yttrium hydride?

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High count rate thermal neutron detectors and electronics

Improved, high count rate thermal neutron counters and electronics enabling new, higher measurement capabilities are disclosed. Next generation 3He and 10B tubes may include an electronics package capable of operating at higher count rates and in higher gamma fields and providing more efficient use of 3He gas. Conventional detector systems may also be upgraded, providing a possible solution to measure spent nuclear fuel with high neutron efficiency previously not possible in 235U fission counter systems. Switching the number of tubes per amplifier allows use of the measured nuclear material for a calibration standard for dead time correction, increasing accuracy of neutron measurements systems. An optimized detector geometry and advanced electronics with double pulse filtering and a dual channel readout may be provided. A bipolar shaper may improve dead time, provide efficient detector use, reduce double pulsing, facilitate high count rate measurements, and allow remote threshold setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring Thermal Conductivity at LH2 Temperatures

For many years, the National Institute of Standards and Technology (NIST) produced reference materials for materials testing. One such reference material was intended for use with a guarded hot plate apparatus designed to meet the requirements of ASTM C177-97, "Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus." This apparatus can be used to test materials in various gaseous environments from atmospheric pressure to a vacuum. It allows the thermal transmission properties of insulating materials to be measured from just above ambient temperature down to temperatures below liquid hydrogen. However, NIST did not generate data below 77 K temperature for the reference material in question. This paper describes a test method used at NASA's Marshall Space Flight Center (MSFC) to optimize thermal conductivity measurements during the development of thermal protection systems. The test method extends the usability range of this reference material by generating data at temperatures lower than 77 K. Information provided by this test is discussed, as are the capabilities of the MSFC Hydrogen Test Facility, where advanced methods for materials testing are routinely developed and optimized in support of aerospace applications.

Selvidge, Shawn↗

A two-axis in-plane motion measurement system based on optical beam deflection

Measurement of in-plane motion with high resolution and large bandwidth enables model-identification and real-time control of motion-stages. This paper presents an optical beam deflection based system for measurement of in-plane motion of both macro- and micro-scale motion stages. A curved reflector is integrated with the motion stage to achieve sensitivity to in-plane translational motion along two axes. Under optimal settings, the measurement system is shown to theoretically achieve sub-angstrom measurement resolution over a bandwidth in excess of 1 kHz and negligible cross-sensitivity to linear motion. Subsequently, the proposed technique is experimentally demonstrated by measuring the in-plane motion of a piezo flexure stage and a scanning probe microcantilever. For the former case, reflective spherical balls of different radii are employed to measure the in-plane motion and the measured sensitivities are shown to agree with theoretical values, on average, to within 8.3%. For the latter case, a prototype polydimethylsiloxane micro-reflector is integrated with the microcantilever. The measured in-plane motion of the microcantilever probe is used to identify nonlinearities and the transient dynamics of the piezo-stage upon which the probe is mounted. These are subsequently compensated by means of feedback control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of Combinatorial Optimization Techniques for Automated Fiber Placement Through Thickness Defect Stack-Up Minimization

The Computer Aided Process Planning (CAPP) module was developed to facilitate and accelerate the process planning workflow for Automated Fiber Placement (AFP). CAPP assists process planners in identifying optimal starting point locations and layup strategies for each ply of a laminate. Ply optimization operates on measurement and scoring of geometry-based defects such as gaps, overlaps, angle deviation, and steering. This paper expands on the established framework for analyzing defect stack-up through thickness of a laminate. Four different combinatorial optimization algorithms are implemented and evaluated: (1) genetic algorithm, (2) differential evolution, (3) particle swarm, and (4) greedy search. The algorithms identify the optimal combination of ply-level layup strategies, by scoring potential laminates on defect stacking, using two different objective functions. A final optimization approach is also presented which trades some performance for a large gain in efficiency. These approaches are compared to a randomized combination using a complex tool surface in a virtual case study. The result is a streamlined methodology for comparing different laminate-level manufacturing strategies and minimizing the through thickness defect stack up.

CAPP↗

Decentralized Carrier Phase Shifting for Optimal Harmonic Minimization in Asymmetric Parallel-Connected Inverters

This paper presents a carrier phase shifting technique for minimizing the aggregate harmonics in networks of asymmetric parallel-connected inverters for distributed power generation system applications. The proposed technique is: 1) implemented in a decentralized manner, relying only on local voltage and current measurements, and 2) optimal in the sense that it minimizes a cost function representing the carrier-frequency current harmonics. The analysis indicates that the proposed optimal carrier phase shifting technique can enable order-of-magnitude reductions in harmonic power, and also universal improvements compared to symmetric carrier interleaving for asymmetric inverter networks. Moreover, compared to existing methods that require either centralized communication or information exchange between inverters to coordinate carriers, the proposed technique is completely decentralized, which provides important practical benefits for implementation, including improved robustness and reduced cost. The technique is experimentally validated on a network of three single-phase 2-kW inverters and demonstrates a 36.5% reduction in the weighted total harmonic distortion factor of the aggregate inverter current, and the ability to converge to the optimal carrier phase spacing dynamically in less than one line frequency cycle (16.7 ms) in steady state and transient operating conditions.

42 ENGINEERING↗

Demonstration of cathode emittance dominated high bunch charge beams in a DC gun-based photoinjector

We present the results of transverse emittance and longitudinal current profile measurements of high bunch charge (≥100 pC) beams produced in the DC gun-based Cornell energy recovery linac photoinjector. In particular, we show that the cathode thermal and core beam emittances dominate the final 95% and core emittances measured at 9–9.5 MeV. Additionally, we demonstrate excellent agreement between optimized 3D space charge simulations and measurement, and show that the quality of the transverse laser distribution limits the optimal simulated and measured emittances. These results, previously thought achievable only with RF guns, demonstrate that DC gun based photoinjectors are capable of delivering beams with sufficient single bunch charge and beam quality suitable for many current and next generation accelerator projects such as Energy Recovery Linacs and Free Electron Lasers.

43 PARTICLE ACCELERATORS↗

High Statistics Analysis using Anisotropic Clover Lattices: (I) Single Hadron Correlation Functions

We present the results of high-statistics calculations of correlation functions generated with single-baryon interpolating operators on an ensemble of dynamical anisotropic gauge-field configurations generated by the Hadron Spectrum Collaboration using a tadpole-improved clover fermion action and Symanzik-improved gauge action. A total of 292,500 sets of measurements are made using 1194 gauge configurations of size 20^3 x 128 with an anisotropy parameter \xi= b_s/b_t = 3.5, a spatial lattice spacing of b_s=0.1227\pm 0.0008 fm, and pion mass of m_\pi ~ 390 MeV. Ground state baryon masses are extracted with fully quantified uncertainties that are at or below the ~0.2%-level in lattice units. The lowest-lying negative-parity states are also extracted albeit with a somewhat lower level of precision. In the case of the nucleon, this negative-parity state is above the N\pi threshold and, therefore, the isospin-1/2 \pi N s-wave scattering phase-shift can be extracted using Luescher's method. The disconnected contributions to this process are included indirectly in the gauge-field configurations and do not require additional calculations. The signal-to-noise ratio in the various correlation functions is explored and is found to degrade exponentially faster than naive expectations on many time-slices. This is due to backward propagating states arising from the anti-periodic boundary conditions imposed on the quark-propagators in the time-direction. We explore how best to distribute computational resources between configuration generation and propagator measurements in order to optimize the extraction of single baryon observables.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A high transmission tender X-ray monochromator employing a matched pair of multilayer grating and mirror

It is now well established that multilayer coated gratings may offer high diffraction efficiencies over the tender X-ray range, from about 1 keV to 5 keV, covering the gap between single layer coated grating monochromators and crystal monochromators. Nevertheless, few beamlines in the world are using such gratings in their monochromator. The successful implementation of a multilayer grating monochromator requires producing a matched pair of a multilayer grating and a multilayer mirror, and this matching is not straightforward as it must account for different incidence angles and refraction effects on each element. Here we review the realization of the multilayer grating monochromator of the SIRIUS beamline which has been successfully in service for several years. We show how, by alternating computer simulation with our diffraction code and measurements, we could optimize the monochromator transmission on a very wide energy range. After the grating was coated, it was found that the angle of optimal efficiency versus photon energy was significantly different from what was predicted by a simple conformal model of binary layers. Layer interdiffusion and profile smoothing during the deposition process must be added to the multilayer model to reproduce the measured data. The critical adjustment of the mirror multilayer period is achieved by the lateral translation of the mirror, which was given a small transverse period gradient. The monochromator is thus providing high transmission efficiency in the 1 to 5 keV energy range, more than 30% over 2.5 keV and up to 46% at 4.6 keV.