Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Effect of Front-Side Silver Metallization on Underlying n+-p Junction in Multicrystalline Silicon Solar Cells: Preprint

We report on the effect of front-side Ag metallization on the underlying n+-p junction of multicrystalline Si solar cells. The junction quality beneath the contacts was investigated by characterizing the uniformities of the electrostatic potential and doping concentration across the junction, using scanning Kelvin probe force microscopy and scanning capacitance microscopy. We investigated cellswith a commercial Ag paste (DuPont PV159) and fired at furnace setting temperatures of 800 degrees, 840 degrees, and 930 degrees C, which results in actual cell temperatures100 degrees C lower than the setting temperature and the three cells being under-, optimal-, and over-fired. We found that the uniformity of the junction beneath the Ag contact was significantly degraded by the over-firing,whereas the junction retained good uniformity with the optimal- and under-fire temperatures. Further, Ag crystallites with widely distributed sizes from <100 nm to several ..mu..m were found at the Ag/Si interface of the over-fired cell. Large crystallites were imaged as protrusions into Si deeper than the junction depth. However, the junction was not broken down; instead, it was reformed on theentire front of the crystallite/Si interface. We propose a mechanism of the junction-quality degradation, based on emitter Si melting at the temperature around the Ag-Si eutectic point during firing, and subsequent recrystallization with incorporation of impurities in the Ag paste and with formation of crystallographic defects during quenching.

14 SOLAR ENERGY↗

Assessing the Thickness of Thin Films Based on Elemental Data Composition of Film Structures

Abstract—We demonstrate the possibility of a quantitative assessment of the thickness of thin films using to measurements of the cationic composition of film structures using the INCA Energy-350 energy dispersion spectrometer that is part of the JSM-6490 LV electron microscope (Japan). The use of this method is especially useful if it is impossible to provide sufficient contrast between the images of the film and substrate sections obtained with a scanning electron microscope on a transverse cleavage of the film structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Further investigation of the characteristics of nodular defects

To increase the understanding of the damage sensitivity of nodular defects and provide exact evidence for theoretical study, the structures and the damage behavior of nodular defects in electron-beam deposited mirrors of HfO2/SiO2 are systemically investigated with a double-beam microscope (focused ion beam, scanning electron microscope). Nodular defects are classified into two kinds. In one kind the boundaries between nodules and the surrounding layers have become continuous for the last deposited materials, and in the other there are discontinuous boundaries between nodules and the surrounding layers. Nodular defects of the first kind typically have low domes, and the second have high domes. Laser damage experiments show that nodular defects of the first kind usually have a high laser resistance, and the laser-induced damage thresholds are limited in the second class of nodules. The dominant parameter of nodular defects related to damage is the height of the nodular defect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of alloying elements on the formation of < c >-component loops in Zr alloy Excel under heavy ion irradiation.

We report here the microstructural changes occurring in the zirconium alloy Excel (Zr-3.5 wt% Sn-0.8Nb-0.8Mo-0.2Fe) during heavy ion irradiation. In situ irradiation experiments were conducted at reactor operating temperatures on two Zr Excel alloy microstructures with different states of alloying elements, with the states achieved by different solution heat treatments. In the first case, the alloying elements were mostly concentrated in the beta (beta) phase, whereas, in the second case, large Zr-3(Mo,Nb,Fe)(4) secondary phase precipitates (SPPs) were grown in the alpha (alpha) phase by long term aging. The heavy ion induced damage and resultant compositional changes were examined using transmission electron microscopy (TEM) in combination with scanning transmission electron microscope (STEM)-energy dispersive x-ray spectroscopy (EDS) mapping. Significant differences were seen in microstructural evolution between the two different microstructures that were irradiated under similar conditions. Nucleation and growth of < c >-component loops and their dependence on the alloying elements are a major focus of the current investigation. It was observed that the < c >-component loops nucleate readily at 100, 300, and 400 degrees C after a threshold incubation dose (TID), which varies with irradiation temperature and the state of alloying elements. It was found that the TID for the formation of < c >-component loops increases with decrease in irradiation temperature. Alloying elements that are present in the form of SPPs increase the TID compared to when they are in the beta phase solid solution. Dose and temperature dependence of loop size and density are presented. Radiation induced redistribution and clustering of alloying elements (Sn, Mo, and Fe) have been observed and related to the formation of < c >-component loops. It has been shown that at the higher temperature tests, irradiation induced dissolution of precipitates occurs whereas irradiation induced amorphization occurs at 100 degrees C. Furthermore, dose and temperature seem to be the main factors governing the dissolution of SPPs and redistribution of alloying elements, which in turn controls the nucleation and growth of < c >-component loops. The correlation between the microstructural evolution and microchemistry has been found by EDS and is discussed in detail.

Idrees, Yasir↗

Studies of Novel Quantum Phenomena in Ruthenates

Strongly correlated oxides have been the subject of intense study in contemporary condensed matter physics, and perovskite ruthenates (Sr,Ca)n+1RunO3n+1 have become a new focus in this field. One of important characteristics of ruthenates is that both lattice and orbital degrees of freedom are active and are strongly coupled to charge and spin degrees of freedom. Such a complex interplay of multiple degrees of freedom causes the properties of ruthenates to exhibit a gigantic response to external stimuli under certain circumstances. Magnetic field, pressure, and chemical composition all have been demonstrated to be effective in inducing electronic/magnetic phase transitions in ruthenates. Therefore, ruthenates are ideal candidates for searching for novel quantum phenomena through controlling external parameters. The objective of this project is to search for novel quantum phenomena in ruthenate materials using high-quality single crystals grown by the floating-zone technique, and investigate the underlying physics. The following summarizes our accomplishments. We have focused on trilayered Sr4Ru3O10 and bilayered (Ca1-xSrx)3Ru2O7. We have succeeded in growing high-quality single crystals of these materials using the floating-zone technique and performed systematic studies on their electronic and magnetic properties through a variety of measurements, including resistivity, Hall coefficient, angle-resolved magnetoresistivity, Hall probe microscopy, and specific heat. We have also studied microscopic magnetic properties for some of these materials using neutron scattering in collaboration with Los Alamos National Laboratory. We have observed a number of unusual exotic quantum phenomena through these studies, such as an orbital selective metamagnetic transition, bulk spin valve effect, and a heavy-mass nearly ferromagnetic state with a surprisingly large Wilson ratio. Our work has also revealed underlying physics of these exotic phenomena. Exotic phenomena of correlated electron has been among central topics of contempary condensed matter physics. Ultrfast phase transitions accompanied by switching of conductivity or magnetization in stronly correlated materials are believed to be promising in developing next generation of transistors. Our work on layered ruthenates has remarkably advanced our understanding of how the exotic phenomena of correlated electrons is governed by the complex interplay between charge, spin, lattice and orbital degrees of freedom. In addition to studies on ruthenates, we have also expanded our research to the emerging field of Fe-based superconductors, focusing on the iron chalcogenide Fe1+y(Te1-xSex) superconductor system. We first studied the superconductivity of this alloy system following the discovery of superconductivity in FeSe using polycrystalline samples. Later, we successfuly grew high-quality single crystals of these materials. Using these single crystals, we have determined the magnetic structure of the parent compound Fe1+yTe, observed spin resonance of superconducting state in optimally doped samples, and established a phase diagram. Our work has produced an important impact in this burgeoning field. The PI presented an invited talk on this topic at APS March meeting in 2010. We have published 19 papers in these two areas (one in Nature materials, five in Physical Review Letters, and nine in Physical Review B) and submitted two (see the list of publications attached below).

36 MATERIALS SCIENCE↗

From Modules to Atoms: Techniques and Characterization for Identifying and Understanding Device-Level Photovoltaic Degradation Mechanisms

This report documents how degraded modules are analyzed for the characterization of cell-level performance reduction. The primary degradation topics presented here are 1) potential-induced degradation, 2) defect metastability and impurity diffusion, and 3) partial-shading-induced reverse-bias breakdown. Imaging techniques, such as electroluminescence imaging, photoluminescence imaging, and lock-in thermography provide spatial information of full modules on the meter scale. Area of interest can then be imaged with higher spatial resolution by zooming in with fields of view near the mm scale. We document procedures for coring cell samples from selected regions of interest using mechanical drilling. The small samples are then of suitable size for various microscopic analyses using techniques such as scanning electron microscopy, time-of-flight secondary ion spectrometry, atomic force microscopy, electron beam induced current, transmission electron microscopy, and atom probe tomography, which can provide chemical, structural, and electrical characterization down to the atomic scale.

14 SOLAR ENERGY↗

The matrices of unequilibrated ordinary chondrites - Implications for the origin and history of chondrites

The matrices of 16 unequilibrated chondrites were examined by optical microscopy, an electron microprobe, and a scanning electron microscope. The fine-grained, opaque, silicate matrix of type 3 unequilibrated chondrites was compositionally, mineralogically, and texturally different from the chondrules and their fragments; it may be the low temperature condensate proposed by Larimer and Anders (1967, 1970). Each meteorite has been metamorphosed by a combination of processes including thermal metamorphism and the passage of shock waves; the appearance of each chondrite results from the temperature and pressure conditions which formed it, and subsequent metamorphic alterations.

Huss, G. R.↗

Nanomechanics and nanometallurgy of boundaries.

One of the tenets of nanotechnology is that the electrical/optical/chemical/biological properties of a material may be changed profoundly when the material is reduced to sufficiently small dimensions - and we can exploit these new properties to achieve novel or greatly improved material's performance. However, there may be mechanical or thermodynamic driving forces that hinder the synthesis of the structure, impair the stability of the structure, or reduce the intended performance of the structure. Examples of these phenomena include de-wetting of films due to high surface tension, thermally-driven instability of nano-grain structure, and defect-related internal dissipation. If we have fundamental knowledge of the mechanical processes at small length scales, we can exploit these new properties to achieve robust nanodevices. To state it simply, the goal of this program is the fundamental understanding of the mechanical properties of materials at small length scales. The research embodied by this program lies at the heart of modern materials science with a guiding focus on structure-property relationships. We have divided this program into three Tasks, which are summarized: (1) Mechanics of Nanostructured Materials (PI Blythe Clark). This task aims to develop a fundamental understanding of the mechanical properties and thermal stability of nanostructured metals, and of the relationship between nano/microstructure and bulk mechanical behavior through a combination of special materials synthesis methods, nanoindentation coupled with finite-element modeling, detailed electron microscopic characterization, and in-situ transmission electron microscopy experiments. (2) Theory of Microstructures and Ensemble Controlled Deformation (PI Elizabeth A. Holm). The goal of this Task is to combine experiment, modeling, and simulation to construct, analyze, and utilize three-dimensional (3D) polycrystalline nanostructures. These full 3D models are critical for elucidating the complete structural geometry, topology, and arrangements that control experimentally-observed phenomena, such as abnormal grain growth, grain rotation, and internal dissipation measured in nanocrystalline metal. (3) Mechanics and Dynamics of Nanostructured and Nanoscale Materials (PI John P. Sullivan). The objective of this Task is to develop atomic-scale understanding of dynamic processes including internal dissipation in nanoscale and nanostructured metals, and phonon transport and boundary scattering in nanoscale structures via internal friction measurements.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of Ce-type FeCrAl-ODS ferritic steel to accident tolerant fuel for BWRs

A Ce-type FeCrAl-ODS ferritic steel has been examined as a candidate Fe-Cr-Al alloy for the fuel cladding in BWRs. The properties examined in this study were the corrosion resistance to coolant water, the resistance to the high temperature steam and the interactions with neighboring materials (UO{sub 2} and B{sub 4}C). For the corrosion test, the specimens were corroded in an autoclave with circulating pure water at 633 K and a pressure of approximately 20 MPa. In addition to the Ce-ODS, MA956 and SS316L alloys were also corroded as reference materials. For the steam oxidation test, the specimens were oxidized in an electric furnace at 1473 K for 100 h and 1573 K for 25 h under wet Ar gas flow. The materials reaction test with B{sub 4}C was carried out at 1573 K and 1673 K for 1 h. The test with UO{sub 2} was performed in a high purity He gas at 1573 K and 1673 K for 1 h. A disk of UO{sub 2} pellet was set on the Ce-ODS specimen and the reaction couple was held in the pure Zr box to prevent a surface oxidation by residual oxidizing gases. The cross sections of reaction couples were observed by an optical microscope (OM) and a secondary electron microscope (SEM) with energy-dispersive spectroscope (EDS) after the materials interaction tests. The results show that the Ce-type FeCrAl-ODS steel has demonstrated a good corrosion resistance to coolant water and high accident tolerances in the oxidation with high temperature steam and in the interactions with neighboring materials. Those favorable properties would imply that the oxide dispersion strengthened (ODS) technology can be a candidate option for further development of accident-tolerant fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compact Microscope Imaging System Developed

The Compact Microscope Imaging System (CMIS) is a diagnostic tool with intelligent controls for use in space, industrial, medical, and security applications. The CMIS can be used in situ with a minimum amount of user intervention. This system, which was developed at the NASA Glenn Research Center, can scan, find areas of interest, focus, and acquire images automatically. Large numbers of multiple cell experiments require microscopy for in situ observations; this is only feasible with compact microscope systems. CMIS is a miniature machine vision system that combines intelligent image processing with remote control capabilities. The software also has a user-friendly interface that can be used independently of the hardware for post-experiment analysis. CMIS has potential commercial uses in the automated online inspection of precision parts, medical imaging, security industry (examination of currency in automated teller machines and fingerprint identification in secure entry locks), environmental industry (automated examination of soil/water samples), biomedical field (automated blood/cell analysis), and microscopy community. CMIS will improve research in several ways: It will expand the capabilities of MSD experiments utilizing microscope technology. It may be used in lunar and Martian experiments (Rover Robot). Because of its reduced size, it will enable experiments that were not feasible previously. It may be incorporated into existing shuttle orbiter and space station experiments, including glove-box-sized experiments as well as ground-based experiments.

McDowell, Mark↗

Structural and optical properties of ZnS/niobate composites synthesized by exfoliation/self-assembly processing

A new ZnS/niobate composite was first synthesized through two processes: (1) self-assembly of [Ca{sub 2}Nb{sub 3}O{sub 10}]{sub n}{sup n-} nanosheets in Zn(NH{sub 3}){sub 4}{sup 2+} solution; (2) formation of ZnS/niobate composite by adding Na{sub 2}S to the former reacting system. X-ray diffraction (XRD) result shows that the as-prepared ZnS/niobate composite can be indexed to tetrahedral symmetry with a=5.450(2) and c=16.904(7) A. The uniform distributions of Zn, Ca, Nb, S and O element in the particles were demonstrated by scanning electron microscope (SEM) and energy dispersive spectrometer (EDS). The optical property of the composite was characterized by photoluminescence spectra and UV-vis absorption spectra. - Graphical abstract: ZnS/niobate composites were first synthesized by exfoliation/self-assembly processing. The composites were characterized by X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), X-ray photoelectron spectroscopy (XPS), scanning electron microscope (SEM) and energy dispersive spectrometer (EDS), IR spectrum, UV-vis spectrum, and photoluminescent spectrum. The photoluminescence spectrum of the ZnS/niobate composite shows blue shift attributed to quantum sizes effects.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Influence of Time-of-Flight Chromatic Aberration on the Dynamics of Propagation of Pulsed Electron Beam in Ultrafast Electron Microscopy: A New Strategy for Better Temporal Resolution

A common strategy aimed at achieving a high temporal resolution in ultrafast electron microscopy and diffraction is based on the use of strong electrostatic fields in the accelerating gap to form fast electron pulses of ultrashort duration. In this work, the dynamics of the propagation of ultrashort photoelectron bunches is studied taking into account the time-of-flight chromatic aberration: the spread-out of electron pulses at the exit from the region of the accelerating electric field. The results of the calculation of the duration of photoelectron pulses taking into account Coulomb repulsion are presented. According to the analysis, the use of strong electrostatic fields in the accelerating gap for the formation of fast electron pulses of ultrashort duration is not a necessary condition for achieving the final high temporal resolution in the method of ultrafast electron microscopy. The modes of operation of ultrafast transmission electron microscope were found for which the temporal resolution increases with the growth of time-of-flight chromatic aberration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

KLASS: Kennedy Launch Academy Simulation System

Software provides access to many sophisticated scientific instrumentation (Scanning Electron Microscope (SEM), a Light Microscope, a Scanning Probe Microscope (covering Scanning Tunneling, Atomic Force, and Magnetic Force microscopy), and an Energy Dispersive Spectrometer for the SEM). Flash animation videos explain how each of the instruments work. Videos on how they are used at NASA and the sample preparation. Measuring and labeling tools provided with each instrument. Hands on experience of controlling the virtual instrument to conduct investigations, much like the real scientists at NASA do. Very open architecture. Open source on SourceForge. Extensive use of XML Target audience is high school and entry-level college students. "Many beginning students never get closer to an electron microscope than the photos in their textbooks. But anyone can get a sense of what the instrument can do by downloading this simulator from NASA's Kennedy Space Center." Science Magazine, April 8th, 2005

Garner, Lesley C.↗

The Art of Automation: Translating Electron Microscopy Workflows Into Automated Processes

Acquiring data using a scanning transmission electron microscope (STEM) is a complex, multi-step process. The intricacy of the process depends on the type of sample, composition of the material, desired results of the experiment, resolution requirement and other experimental factors. Each experiment presents unique complications, such as sample drift and contamination, that the microscopist must consider when acquiring data. All these challenges are handled fluidly and expertly by experienced microscopists, but to reach new levels of innovation in material development, including greater reproducibility, throughput, and precision, the automation of these workflows is essential. The initial phase of this work involved translating intuition-based workflows into discrete, programmable steps. Some common key stages in STEM workflows are the initial tuning, scanning the sample for areas of interest, and then acquiring the data. Each stage can be broken further into specific parameter adjustments, such as aberration correction and dwell time optimization, depending on the experiment. When deconstructing various experiments each step was assessed for automation feasibility based on the amount of real time operator decisions. There are steps that lend themselves to automation more readily than others, such as course focusing and sample screening, but there is potential for full automation of all stages with time. As an initial step, an automated montage routine was developed, allowing for the efficient acquisition of large portions of the sample without requiring continuous intervention from the operator. The automation of this small process of the procedure demonstrates the value of this capability. A major challenge in automation arises from discrepancies between commanded, reported and actual stage movements. Using systematic tests, stage movement was quantified. This error can be corrected algorithmically for more accurate workflows in the future. Expanding automation capabilities would result in larger, more efficient data acquisition which allows for more robust statistical analysis. Additionally, this work lays the groundwork for a closed loop system where machine learning algorithms would intake automatically acquired data and make real time decisions. By progressively automating this instrument, this work establishes the foundation for fully automated experimentation in transmission electron microscopy.

97 MATHEMATICS AND COMPUTING↗

The role of biomineralization in microbiologically influenced corrosion

Synthetic iron oxides (goethite, alpha-FeO.OH; hematite, Fe2O3; and ferrihydrite, Fe(OH)3) were used as model compounds to simulate the mineralogy of surface films on carbon steel. Dissolution of these oxides exposed to pure cultures of the metal-reducing bacterium, Shewanella putrefaciens, was followed by direct atomic absorption spectroscopy measurement of ferrous iron coupled with microscopic analyses using confocal laser scanning and environmental scanning electron microscopies. During an 8-day exposure the organism colonized mineral surfaces and reduced solid ferric oxides to soluble ferrous ions. Elemental composition, as monitored by energy dispersive x-ray spectroscopy, indicated mineral replacement reactions with both ferrihydrite and goethite as iron reduction occurred. When carbon steel electrodes were exposed to S. putrefaciens, microbiologically influenced corrosion was demonstrated electrochemically and microscopically.

Non-programmatic↗

Autopilot for frequency-modulation atomic force microscopy

One of the most challenging aspects of operating an atomic force microscope (AFM) is finding optimal feedback parameters. This statement applies particularly to frequency-modulation AFM (FM-AFM), which utilizes three feedback loops to control the cantilever excitation amplitude, cantilever excitation frequency, and z-piezo extension. These loops are regulated by a set of feedback parameters, tuned by the user to optimize stability, sensitivity, and noise in the imaging process. Optimization of these parameters is difficult due to the coupling between the frequency and z-piezo feedback loops by the non-linear tip-sample interaction. Four proportional-integral (PI) parameters and two lock-in parameters regulating these loops require simultaneous optimization in the presence of a varying unknown tip-sample coupling. Presently, this optimization is done manually in a tedious process of trial and error. Here, we report on the development and implementation of an algorithm that computes the control parameters automatically. The algorithm reads the unperturbed cantilever resonance frequency, its quality factor, and the z-piezo driving signal power spectral density. It analyzes the poles and zeros of the total closed loop transfer function, extracts the unknown tip-sample transfer function, and finds four PI parameters and two lock-in parameters for the frequency and z-piezo control loops that optimize the bandwidth and step response of the total system. Implementation of the algorithm in a home-built AFM shows that the calculated parameters are consistently excellent and rarely require further tweaking by the user. The new algorithm saves the precious time of experienced users, facilitates utilization of FM-AFM by casual users, and removes the main hurdle on the way to fully automated FM-AFM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanomechanical squeezing: Toward quantum imaging with atomic force microscopy

Leveraging quantum effects in mechanical oscillators promises major advancements in nanometrology, including sensing and imaging. Microscopic cantilevers serve as versatile force sensors with broad applications in nanoscience, nanotechnology, and, increasingly, quantum sensing. Here, we theoretically model and investigate the quantum mechanics of cantilever probes in atomic force microscopy under conditions of reduced thermal noise. Specifically, our model captures the cantilever interaction with a surface via long-range attractive van der Waals forces and short-range repulsive-adhesive interactions described by the Derjaguin-Muller-Toporov model. We find that when the probe resides within the attractive interaction regime, a coherent state emerges, whereas, in the repulsive regime, a squeezed state forms for the cantilever's deformation state. Our calculations explain the functional role of interaction potentials in the quantum dynamics of macroscopic mechanical systems, which are proving useful in quantum sensing and information processing. The presented calculations can be extended to investigate other interaction forces relevant to atomic force microscopy.

Al-Sawai, Wael M. [Lamar Univ., Beaumont, TX (Unit↗

Grain size determination in nano-scale polycrystalline aggregates by precession illumination-hollow cone dark field imaging in the transmission electron microscope

Precession illumination hollow cone dark field (PI-HCDF) transmission electron microscopy (TEM) provides high contrast multi-beam dark field images, which are suitable for effective and robust grain size measurements in nano-scale polycrystalline aggregates. Precession illumination with slightly converged electron beam probes and precession angles up to 3 Degree-Sign has been produced using a computer-controlled system using a JEOL JEM 2000FX TEM instrument. Theoretical and practical aspects of the experimental technique are discussed using example precession illumination hollow cone diffraction patterns from single crystalline NiAl and the importance of selecting the appropriate precession angle for PI-HCDF image formation and interpretation is described. Results obtained for precession illumination are compared with those of conventional parallel beam illumination experiments. Nanocrystalline Al has been used to evaluate the influence of the precession angle on PI-HCDF image contrast with a focus on grain size analysis. PI-HCDF imaging has been applied for grain size measurements in regions of a nanocrystalline Al thin film adjacent to the edge of a pulsed laser melted and rapidly solidified region and determined the dimensions of a heat-affected zone. - Highlights: Black-Right-Pointing-Pointer New TEM method for grain size measurements combines TEM resolution with obtainability of statistically significant data sets. Black-Right-Pointing-Pointer We use precession illumination to produce time precession illumination hollow cone diffraction patterns PI-HCDP. Black-Right-Pointing-Pointer Contrast in dark field images (PI-HCDF) formed from PI-HCDP is easy to interpret as dynamical effects are reduced. Black-Right-Pointing-Pointer PI-HCDFs use several time-averaged g-rings simultaneously and contain more information than conventional DF-images. Black-Right-Pointing-Pointer Easy contrast interpretation and less dark field images required, allows fast, robust and reliable grain size determination.

36 MATERIALS SCIENCE↗