Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Fusion alpha-particle losses in a high-beta rippled tokamak

In tokamak plasmas, the confinement of energetic ions depends on the magnetic field structure. If the plasma pressure is finite, the equilibrium current (i.e., the Pfirsch-Schlüter current and diamagnetic current) flows in the plasma to maintain the magnetohydrodynamic (MHD) equilibrium. These plasma currents generate poloidal and toroidal magnetic field and alter the field structure. Moreover, if we consider the non-axisymmetry of magnetic field structures such as toroidal field (TF) ripples, the non-axisymmetric component of the equilibrium current can alter TF ripples themselves. When the plasma beta becomes high, the changes in the field structure due to the equilibrium current might affect the confinement of energetic ions significantly. We intend to clarify how these currents alter the field structure and affect the confinement of alpha particles in high-beta plasma. The MHD equilibrium is calculated using VMEC and the orbits of fusion alpha particles are followed by using the fully three-dimensional magnetic field orbit-following Monte Carlo code. In relatively low-beta plasma (e.g., the volume-averaged beta value <β>≤2%), the changes in the magnetic field component due to the plasma current negligibly affect the confinement of alpha particles except for the Shafranov shift effect. However, for <β>≥3%, the diamagnetic effect reduces the magnetic field strength and significantly increases alpha-particle losses. In these high-beta cases, the non-axisymmetric field component generated by the equilibrium current also increases these losses, but not as effectively as compared to the diamagnetic effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fission matrix capability for MCNP, Part II - Applications

This paper describes the initial experience and results from implementing a fission matrix capability into the MCNP Monte Carlo code. The fission matrix is obtained at essentially no cost during the normal simulation for criticality calculations. It can be used to provide estimates of the fundamental mode power distribution, the reactor dominance ratio, the eigenvalue spectrum, and higher mode spatial eigenfunctions. It can also be used to accelerate the convergence of the power method iterations. Past difficulties and limitations of the fission matrix approach are overcome with a new sparse representation of the matrix, permitting much larger and more accurate fission matrix representations. Numerous examples are presented. A companion paper (Part I - Theory) describes the theoretical basis for the fission matrix method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multigroup cross section generation capability in GRIFFIN

GRIFFIN is an advanced reactor multiphysics application built on the object-oriented simulation environment (MOOSE) and is jointly developed by Idaho National Laboratory and Argonne National Laboratory. The cross section application programming interface, originally developed for the PROTEUS code, has been integrated into GRIFFIN to prepare cross sections for thermal reactor applications with heterogeneous geometries. Additional improvements have been made by implementing an on-the-fly slowing down method, a double heterogeneity treatment capability, and updating the procedure to generate the fine multigroup library. The cross section preparation capability in GRIFFIN was verified for graphite-moderated TRISO fuel-based reactor benchmark problems: unit-cell problems of VHTR and EMPIRE micro reactor and HTTR assembly problems. Eigenvalues and multigroup cross sections of GRIFFIN agreed very well with those of the continuous-energy Monte Carlo code Serpent2 within 200 pcm in eigenvalue and 2% in cross sections. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SPECTROPOLARIMETRY OF SUPERLUMINOUS SUPERNOVAE: INSIGHT INTO THEIR GEOMETRY

We present the first spectropolarimetric observations of a hydrogen-free superluminous supernova (SLSN) at z = 0.1136, namely SN 2015bn. The transient shows significant polarization at both of the observed epochs: one 24 days before maximum light in the rest-frame, and the other at 27 days after peak luminosity. Analysis of the Q – U plane suggests the presence of a dominant axis and no physical departure from the main axis at either epoch. The polarization spectrum along the dominant axis is characterized by a strong wavelength dependence and an increase in the signal from the first to the second epoch. We use a Monte Carlo code to demonstrate that these properties are consistent with a simple toy model that adopts an axisymmetric ellipsoidal configuration for the ejecta. We find that the wavelength dependence of the polarization is possibly due to a strong wavelength dependence in the line opacity, while the higher level of polarization at the second epoch is a consequence of the increase in the asphericity of the inner layers of the ejecta or the fact that the photosphere recedes into less spherical layers. The geometry of the SLSN is similar to that of stripped-envelope core-collapse SNe connected to GRB, while the overall evolution of the ejecta shape could be consistent with a central engine.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrons scattered inside small dust grains of various materials

The dust grain charge in an electron beam is given by a difference in numbers of electrons that fall onto the grain and those leaving it. Electrons with energies exceeding 1 keV can penetrate through submicron-sized dust grains. If the grain is small enough, a yield of these electrons reaches unity but they leave a part of their energy inside the grain and this energy excites secondary electrons. The paper presents a hybrid Monte Carlo code that simulates paths of the primary electrons inside a spherical grain and provides the yield of scattered electrons and their energy spectrum as a function of the grain size and material. This code is based on the Richterovaet al. [Phys. Rev. B 74, 235430 (2006)] model but it includes several corrections important for light materials like carbon or ice. The model was verified using experimental results obtained on large planar samples. For spherical samples, we have found that the yield of scattered electrons reaches unity for 50 nm Au grains illuminated by 5 keV electrons, whereas the same effect can be observed on approx =1000 nm carbon grains.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-H-BRA-08: A Monte Carlo Cell Nucleus Model for Assessing Cell Survival Probability Based On Particle Track Structure Analysis

Purpose: To correlate the damage produced by particles of different types and qualities to cell survival on the basis of nanodosimetric analysis and advanced DNA structures in the cell nucleus. Methods: A Monte Carlo code was developed to simulate subnuclear DNA chromatin fibers (CFs) of 30nm utilizing a mean-free-path approach common to radiation transport. The cell nucleus was modeled as a spherical region containing 6000 chromatin-dense domains (CDs) of 400nm diameter, with additional CFs modeled in a sparser interchromatin region. The Geant4-DNA code was utilized to produce a particle track database representing various particles at different energies and dose quantities. These tracks were used to stochastically position the DNA structures based on their mean free path to interaction with CFs. Excitation and ionization events intersecting CFs were analyzed using the DBSCAN clustering algorithm for assessment of the likelihood of producing DSBs. Simulated DSBs were then assessed based on their proximity to one another for a probability of inducing cell death. Results: Variations in energy deposition to chromatin fibers match expectations based on differences in particle track structure. The quality of damage to CFs based on different particle types indicate more severe damage by high-LET radiation than low-LET radiation of identical particles. In addition, the model indicates more severe damage by protons than of alpha particles of same LET, which is consistent with differences in their track structure. Cell survival curves have been produced showing the L-Q behavior of sparsely ionizing radiation. Conclusion: Initial results indicate the feasibility of producing cell survival curves based on the Monte Carlo cell nucleus method. Accurate correlation between simulated DNA damage to cell survival on the basis of nanodosimetric analysis can provide insight into the biological responses to various radiation types. Current efforts are directed at producing cell survival curves for high-LET radiation.

60 APPLIED LIFE SCIENCES↗

Modeling multiple scattering transient of an ultrashort laser pulse by spherical particles

The multiple scattering of an ultrashort laser pulse by a turbid dispersive medium (namely a cloud of bubbles in water) is investigated by means of Monte Carlo simulations. The theory of Gouesbet and Gréhan (2000) is used to derive an energetic model of the scattering transient. It is shown that the spreading and extinction of the pulse can be decoupled from the transient of scattering, which allows to describe each phenomenon individually. The transient of scattering is modeled with the Lorenz-Mie Theory and thus is also valid for a relative refractive index lower than one, contrary to the Debye series expansion which does not converge close to the critical angle. This is made possible after the introduction of a new physical object, the Scattering Impulse Response Function (SIRF) which allows to detect the different modes of scattering transient, in time and direction. Here the present approach is more generic, as it enables to simulate clouds of air bubbles in water, which was not possible previously. Two different approaches are proposed within the Monte Carlo framework. The first is a pure Monte Carlo approach where the delay due to the scattering is randomly drawn at each event, while the second is based on the transport of the whole scattering signal. They are both embedded in the Monte Carlo code Scatter3D. Both models produce equivalent trends and are validated against published numerical results. They are then applied to the multiple scattering of ultra short pulse by a cloud of bubble in water in the forward direction. The pulse spread due to the propagation in water is computed for a wide range of traveled distances and pulse durations, and the optimal pulse duration is given to minimize the pulse spread at a given distance. The main result is that the scattered photons exit the turbid medium earlier than the ballistic photons and produce a double peak related to the refraction in the bubble. This demonstrates the possibility to develop new diagnostics to characterize dynamic bubbly flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterisation of a MeV Bremsstrahlung x-ray source produced from a high intensity laser for high areal density object radiography

Results of an experiment to characterise a MeV Bremsstrahlung x-ray emission created by a short (<10 ps) pulse, high intensity (1.4 × 10{sup 19} W/cm{sup 2}) laser are presented. X-ray emission is characterized using several diagnostics; nuclear activation measurements, a calibrated hard x-ray spectrometer, and dosimeters. Results from the reconstructed x-ray energy spectra are consistent with numerical simulations using the PIC and Monte Carlo codes between 0.3 and 30 MeV. The intense Bremsstrahlung x-ray source is used to radiograph an image quality indicator (IQI) heavily filtered with thick tungsten absorbers. Observations suggest that internal features of the IQI can be resolved up to an external areal density of 85 g/cm{sup 2}. The x-ray source size, inferred by the radiography of a thick resolution grid, is estimated to be approximately 400 μm (full width half maximum of the x-ray source Point Spread Function)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of the data acquisition chain of scintillation detectors

The good performance of a detector can be strongly affected by the instrumentation used to acquire the data. The possibility of anticipating how the acquisition chain will affect the signal can help in finding the best solution among different set-ups. In this work we developed a Monte Carlo code that aims to simulate the effect of the various components of a digital Data Acquisition system (DAQ) applied to scintillation detectors. The components included in the model are: the scintillator, the photomultiplier tube (PMT), the signal cable and the digitizer. We benchmarked the code against real data acquired with a NE213 scintillator, comparing simulated and real signal pulses induced by gamma-ray interaction. Then we studied the dependence of the energy resolution of a pulse height spectrum (PHS) on the sampling frequency and the bit resolution of the digitizer. We found that exceeding some values of the sampling frequency and the bit resolution improves only marginally the performance of the system. The method can be applied for the study of various detector systems relevant for nuclear techniques, such as in fusion diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-C-17A-12: Towards a Passively Optimized Phase-Space Monte Carlo (POPMC) Treatment Planning Method: A Proof of Principle

Purpose: The advent of on-line/off-line adaptive, and biologically-conformal radiation therapy has led to a need for treatment planning solutions that utilize voxel-specific penalties, requiring optimization over a large solution space that is performed quickly, and the dose in each voxel calculated accurately. This work proposes a “passive” optimization framework, which is executed concurrently during Monte Carlo dose calculation, evaluating the cost/benefit of each history during transport, and creates a passively optimized fluence map. Methods: The Monte Carlo code Geant4 v9.6 was used for this study. The standard voxel geometry implementation was modified to support the passive optimization framework, with voxel-specific optimization parameters. Dose-benefit functions, which will increase a particle history’s weight upon dose deposition, were defined in a central collection of voxels to effectively create target structures. Histories that deposit energy to voxels are reweighted based on a voxel’s dose multiplied by its cost/benefit value. Upon full termination of each history, the dose contributions of that history are reweighted to reflect a contribution proportional to the history’s final weight. A parallel-planar 1.25 MeV photon fluence is transported through the geometry, and re-weighted at each dose deposition step. The resulting weight is tallied with the incident spatial and directional coordinates in a phase-space distribution. Results: A uniform incident fluence was reweighted during MC dose calculations to create an optimized fluence map which would generate dose profiles in target volumes that exhibit the same dose characteristics as the prescribed optimization parameters. An optimized dose profile, calculated concurrently with the phase-space, reflects the resulting dose distribution. Conclusion: This study demonstrated the feasibility of passively optimizing an incident fluence map during Monte Carlo dose calculations. The flexibility of the voxel-specific optimization framework allows a variety and combination of optimization parameters to be calculated for each voxel at every transportation step. This work is partially supported by Varian. This work is partially supported by the NIH.

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo simulation for excessive Balmer line broadening generated by transport of fast H Atoms in an abnormal glow discharge

Monte Carlo code for fast hydrogen atom transport and generating of excessively Doppler broadened profiles based on the collision model is presented. Results for the initial monoenergetic atom beam and for a more realistic energy distribution of H atoms are reported. Line profiles obtained from the simulation are compared to our experimentally obtained data. Initial energy distribution for atoms is approximately calculated from the measured line profiles while the initial angle distribution was taken to be cosine. Balmer alpha intensity was found to exponentially decay in the negative glow region, which concurs with the experimental results. These agreements between the simulation and experiment support the collision model for excessive line broadening.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-602: Beryllium Seeds Implant for Photo-Neutron Yield Using External Beam Therapy

Purpose: To evaluate the Neutron yield obtained during prostate external beam irradiation. Methods: Neutrons, that are commonly a radiation safety concern for photon beams with energy above 10 MV, are induced inside a PTV from Beryllium implemented seeds. A high megavoltage photon beam delivered to a prostate will yield neutrons via the reaction Be-9(γ,n)2?. Beryllium was chosen for its low gamma,n reaction cross-section threshold (1.67 MeV) to be combined with a high feasible 25 MV photon beam. This beam spectra has a most probable photon energy of 2.5 to 3.0 MeV and an average photon energy of about 5.8 MeV. For this feasibility study we simulated a Beryllium-made common seed dimension (0.1 cm diameter and 0.5 cm height) without taking into account encapsulation. We created a 0.5 cm grid loading pattern excluding the Urethra, using Variseed (Varian inc.) A total of 156 seeds were exported to a 4cm diameter prostate sphere, created in Fluka, a particle transport Monte Carlo Code. Two opposed 25 MV beams were simulated. The evaluation of the neutron dose was done by adjusting the simulated photon dose to a common prostate delivery (e.g. 7560 cGy in 42 fractions) and finding the corresponding neutron dose yield from the simulation. A variance reduction technique was conducted for the neutrons yield and transported. Results: An effective dose of 3.65 cGy due to neutrons was found in the prostate volume. The dose to central areas of the prostate was found to be about 10 cGy. Conclusion: The neutron dose yielded does not justify a clinical implant of Beryllium seeds. Nevertheless, one should investigate the Neutron dose obtained when a larger Beryllium loading is combined with commercially available 40 MeV Linacs.

07 ISOTOPE AND RADIATION SOURCES↗

TH-CD-209-06: LET-Based Adjustment of IMPT Plans Using Prioritized Optimization

Purpose: In-vitro experiments suggest an increase in proton relative biological effectiveness (RBE) towards the end of range. However, proton treatment planning and dose reporting for clinical outcome assessment has been based on physical dose and constant RBE. Therefore, treatment planning for intensity-modulated proton therapy (IMPT) is unlikely to transition radically to pure RBE-based planning. We suggest a hybrid approach where treatment plans are initially created based on physical dose constraints and prescriptions, and are subsequently altered to avoid high linear energy transfer (LET) in critical structures while limiting the degradation of the physical dose distribution. Methods: To allow fast optimization based on dose and LET we extended a GPU-based Monte-Carlo code towards providing dose-averaged LET in addition to dose for all pencil beams. After optimizing an initial IMPT plan based on physical dose, a prioritized optimization scheme is used to modify the LET distribution while constraining the physical dose objectives to values close to the initial plan. The LET optimization step is performed based on objective functions evaluated for the product of physical dose and LET (LETxD). To first approximation, LETxD represents a measure of the additional biological dose that is caused by high LET. Regarding optimization techniques, LETxD has the advantage of being a linear function of the pencil beam intensities. Results: The method is applicable to treatments where serial critical structures with maximum dose constraint are located in or near the target. We studied intra-cranial tumors (high-grade meningiomas, base-of-skull chordomas) where the target (CTV) overlaps with the brainstem and optic structures. Often, high LETxD in critical structures can be avoided while minimally compromising physical dose planning objectives. Conclusion: LET-based re-optimization of IMPT plans represents a pragmatic approach to bridge the gap between purely physical dose-based and RBE-based planning. It can be realized with fast GPU-based Monte-Carlo dose calculation. The project was in part supported by NIH grants U19 CA 021239-36 and C06 CA 059267.

60 APPLIED LIFE SCIENCES↗

Evaluation for 4S core nuclear design method through integration of benchmark data

The 4S is a sodium-cooled small fast reactor which is reflector-controlled for operation through core lifetime about 30 years. The nuclear design method has been selected to treat neutron leakage with high accuracy. It consists of a continuous-energy Monte Carlo code, discrete ordinate transport codes and JENDL-3.3. These two types of neutronic analysis codes are used for the design in a complementary manner. The accuracy of the codes has been evaluated by analysis of benchmark critical experiments and the experimental reactor data. The measured data used for the evaluation is critical experimental data of the FCA XXIII as a physics mockup assembly of the 4S core, FCA XVI, FCA XIX, ZPR, and data of experimental reactor JOYO MK-1. Evaluated characteristics are criticality, reflector reactivity worth, power distribution, absorber reactivity worth, and sodium void worth. A multi-component bias method was applied, especially to improve the accuracy of sodium void reactivity worth. As the result, it has been confirmed that the 4S core nuclear design method provides good accuracy, and typical bias factors and their uncertainties are determined. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MC21 analysis of the nuclear energy agency Monte Carlo performance benchmark problem

Due to the steadily decreasing cost and wider availability of large scale computing platforms, there is growing interest in the prospects for the use of Monte Carlo for reactor design calculations that are currently performed using few-group diffusion theory or other low-order methods. To facilitate the monitoring of the progress being made toward the goal of practical full-core reactor design calculations using Monte Carlo, a performance benchmark has been developed and made available through the Nuclear Energy Agency. A first analysis of this benchmark using the MC21 Monte Carlo code was reported on in 2010, and several practical difficulties were highlighted. In this paper, a newer version of MC21 that addresses some of these difficulties has been applied to the benchmark. In particular, the confidence-interval-determination method has been improved to eliminate source correlation bias, and a fission-source-weighting method has been implemented to provide a more uniform distribution of statistical uncertainties. In addition, the Forward-Weighted, Consistent-Adjoint-Driven Importance Sampling methodology has been applied to the benchmark problem. Results of several analyses using these methods are presented, as well as results from a very large calculation with statistical uncertainties that approach what is needed for design applications. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TOWARD UNDERSTANDING THE ENVIRONMENT OF R MONOCEROTIS FROM HIGH-RESOLUTION NEAR-INFRARED POLARIMETRIC OBSERVATIONS

High-resolution H-band imaging polarimetric observations of R Mon obtained at the Canada-France-Hawaii telescope are presented. These data show a centrosymmetric pattern with elongated intensity contours mostly due to the presence of the companion R Mon B. We also consider published R-band data, which show an extended right-angle conical reflection nebula with an offset in the optical peak. We study the circumstellar environment of R Mon with a radiative transfer Monte Carlo code. The best-fitting model obtained succeeds in reproducing the characteristics seen in the data in the two bands simultaneously. The model indicates the presence of relatively small astronomical silicate grains ranging from 0.04 {mu}m to 0.15 {mu}m distributed into three structures: a small disk, an inner envelope, and an outer envelope. The cavity is modeled by a conical structure with a constant low density and we include a 'throat' to produce the offset of the optical peak. Our model predicts a polarization reversal by 90{sup 0} between the R and H bands. Observations show that position angles parallel, perpendicular, and also at other angles to the disk can occur over time in the near-infrared.

79 ASTRONOMY AND ASTROPHYSICS↗

Interpolations of nuclide-specific scattering kernels generated with Serpent

The neutron group-to-group scattering cross section is an essential input parameter for any multi-energy group physics model. However, if the analyst prefers to use Monte Carlo transport to generate group constants this data is difficult to obtain for a single species of a material. Here, the Monte Carlo code Serpent was modified to return the group transfer probabilities on a per-nuclide basis. This ability is demonstrated in conjunction with an essential physics reactor model where cross section perturbations are used to dynamically generate reactor state dependent group constants via interpolation from pre-computed libraries. The modified version of Serpent was therefore verified with three interpolation cases designed to test the resilience of the interpolation scheme to changes in intra-group fluxes. For most species, interpolation resulted in errors of less than 5% of transport-computed values. For important scatterers, such as {sup 1}H, errors less than 2% were observed. For nuclides with high errors ( > 10%), the scattering channel typically only had a small probability of occurring. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advances in Performance of Microchannel Plate Detectors for HEDP Diagnostics

In recent years, a team from NSTec and SNL has built a unique capability to develop microchannel plate (MCP)?based framing x-ray cameras for HEDP diagnostics. At the SNL Z facility, multistrip MCP detectors to record up to eight channels are employed in 2-D, sub-nanosecond time-resolved imaging and time- and space-resolved spectroscopy diagnostics. Progressively more stringent technical temporal resolution and response uniformity requirements have necessitated a systematic design approach based on iterative modeling of the MCP using inputs from electrical circuit characterization. An inherently large exponential dependence in MCP gain, V{sup 11.5}, has mandated a firm understanding of the applied voltage pulse shape propagating across the strip. We pioneered direct measurements of the propagating waveform using a Picoprobe{reg_sign} and developed a Monte Carlo code to simulate MCP response to compare against test measurements. This scheme is shown in Figure 1. The simulation detailed a physical model of the cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Using this design approach, we began to characterize the newly developed second-generation detector (H-CA-65) by using a Manson x-ray source to evaluate the following DC characteristics: MCP sensitivity as a function of bias voltage, flat-field uniformity and spatial resolution, and variation of spatial resolution and sensitivity as a function of phosphor bias voltage. Dynamic performance and temporal response were obtained by using an NSTec short-pulse laser to measure optical gate profiles, saturation, and dynamic range. These data were processed and combined to obtain the gain variation and gate profiles for any position along an MCP strip. Typical position-sensitive gate profiles of the detector are shown in Figure 2. The measured gate profiles for the latest design have shown excellent agreement with Monte Carlo simulations. This modeling success provides us with a powerful tool for designing and optimizing MCP detectors that will meet specified requirements. For example, the pulse-forming network (PFN) pulse width can be chosen based on Monte Carlo simulation to achieve the shortest gate profiles without loss of significant gain. In Figure 2, a 150-ps FWHM gate profile was determined to be the inherent response time of our detector, This is close to the transit time of the electrons inside the MCP. The difference between design and measured performance of the H-CA-65 is within experimental errors. The most exciting outcome from the characterize/model process is that MCP gain uniformity can be achieved by adjusting output circuit impedance and judiciously selecting an appropriately wide voltage pulse waveform to drive the MCP strip. The combination of impedance, reflection ratio, and pulse shape/width can be optimized to provide a uniform pulse to propagate across a strip. Figure 3 shows the sensitivity measured across an MCP strip for an old-style SNL detector and the H-CA-65. The H-CA-65's uniformity is 30% or better for a strip driven by a 300-ps FWHM PFN (yielding a 150-ps FWHM optical gate profile), compared to a factor of five or less for the old detector. For the time-resolved spectroscopy diagnostic at Z, gain uniformity across the strip is a much more critical criterion than a narrow optical gate. A gain uniformity of 10% along the MCP strip was achieved when driven by a 700-ps FWHM PFN (yielding a 250-ps FWHM optical gate), a two order of magnitude improvement. The developments that produced the H-CA-65, which are now part of our MCP design process, have reduced product cost and the time it takes to develop and characterize the new MCP detectors.