Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Minimum-Time and Vibration Avoidance Attitude Maneuver for Spacecraft with Torque and Momentum Limit Constraints in Redundant Reaction Wheel Configuration

In this paper, we present an optimal open-loop slew trajectory algorithm developed at GSFC for the so-called "Yardstick design" of the James Webb Space Telescope (JWST). JWST is an orbiting infrared observatory featuring a lightweight, segmented primary mirror approximately 6 meters in diameter and a sunshield approximately the size of a tennis court. This large, flexible structure will have significant number of lightly damped, dominant flexible modes. With very stringent requirements on pointing accuracy and image quality, it is important that slewing be done within the required time constraint and with minimal induced vibration in order to maximize observing efficiency. With reaction wheels as control actuators, initial wheel speeds as well as individual wheel torque and momentum limits become dominant constraints in slew performance. These constraints must be taken into account when performing slews to ensure that unexpected reaction wheel saturation does not occur, since such saturation leads to control failure in accurately tracking commanded motion and produces high frequency torque components capable of exciting structural modes. A minimum-time constraint is also included and coupled with reaction wheel limit constraints in the optimization to minimize both the effect of the control torque on the flexible body motion and the maneuver time. The optimization is on slew command parameters, such as maximum slew velocity and acceleration, for a given redundant reaction wheel configuration and is based on the dynamic interaction between the spacecraft and reaction wheel motion. Analytical development of the slew algorithm to generate desired slew position, rate, and acceleration profiles to command a feedback/feed forward control system is described. High-fidelity simulation and experimental results are presented to show that the developed slew law achieves the objectives.

Ha, Kong Q.↗

ATLAST-9.2: A Deployable Large Aperture UVOIR Space Telescope

We present the results of a study of a deployable version of the Advanced Technology Large Aperture Space Telescope (ATLAST) that could be launched on an Evolved Expendable Launch Vehicle (EELV). ATLAST is a concept for a next-generation UVOIR observatory to follow HST and JWST. The observatory retains significant heritage from JWST, thereby taking advantage of technologies and engineering already developed for that mission. At the same time, we have identified several design changes to the JWST architecture, some of which are required due to the demanding wavefront error requirements at visible wavelengths. The optical telescope assembly has a segmented 9.2-meter aperture and consists of 36 hexagonal glass mirrors, each of which is I.3l5m in size (flat-to-flat). The telescope can be folded to fit in the 6.5m fairing on the planned upgrade to the Delta-IV heavy launch vehicle. Near-real time wavefront sensing and control is performed on-board the telescope using stars in the field of view to deliver diffraction limited imaging performance at 500nm wavelength. The optical design of the telescope provides an 8x20 arcmin FOV in which 4-5 instruments can be accommodated, plus fine guidance and wavefront sensors. Unlike JWST, the OTA sits at the end of a multi-gimbaled arm, allowing pitch and roll motion, and is isolated from the sunshield and spacecraft bus by an active isolation system. Our design permits servicing in order to extend the life of the observatory.

Oegerle, William R.↗

The Kinematic and Microphysical Control of Storm Integrated Lightning Flash Extent

The objective of this preliminary study is to investigate the kinematic and microphysical control of lightning properties, particularly those that may govern the production of nitrogen oxides (NOx) in thunderstorms, such as flash rate, type and extent. The mixed-phase region is where the noninductive charging (NIC) process is thought to generate most storm electrification during rebounding collisions between ice particles in the presence of supercooled water. As a result, prior radar-based studies have demonstrated that lightning flash rate is well correlated to kinematic and microphysical properties in the mixed-phase region of thunderstorms such as updraft volume, graupel mass, or ice mass flux. There is also some evidence that lightning type is associated with the convective state. Intracloud (IC) lightning tends to dominate during the updraft accumulation of precipitation ice mass while cloud-to-ground (CG) lightning is more numerous during the downdraft-driven descent of radar echo associated with graupel and hail. More study is required to generalize these relationships, especially regarding lightning type, in a wide variety of storm modes and meteorological conditions. Less is known about the co-evolving relationship between storm kinematics, microphysics, morphology and three-dimensional flash extent, despite its importance for lightning NOx production. To address this conceptual gap, the NASA MSFC Lightning Nitrogen Oxides Model (LNOM) is applied to North Alabama Lightning Mapping Array (NALMA) and Vaisala National Lightning Detection NetworkTM (NLDN) observations following ordinary convective cells through their lifecycle. LNOM provides estimates of flash type, channel length distributions, lightning segment altitude distributions (SADs) and lightning NOx production profiles. For this study, LNOM is applied in a Lagrangian sense to well isolated convective cells on 3 April 2007 (single cell and multi-cell hailstorm, non-severe multicell) and 6 July 2007 (non-severe multi-cell) over Northern Alabama. The LNOM lightning characteristics are compared to the evolution of updraft and precipitation properties inferred from dual-Doppler and polarimetric radar analyses applied to observations from a nearby Doppler radar network, including the UA Huntsville Advanced Radar for Meteorological and Operational Research (ARMOR, C-band, polarimetric). The LNOM estimated SAD and lightning NOx production profiles are placed in the context of radar derived profiles of vertical motion, precipitation types and amounts. Finally, these analyses are used to determine if storm integrated flash channel extent is as well correlated to volumetric updraft and precipitation ice characteristics in the mixed phase region as flash rate for these individual convective cells.

Carey, Lawrence↗

Novel Radiometry for In-Pipe Robotic Inspection of Holdup Deposits in Gaseous Diffusion Piping - 19503

This paper details the first complete, DOE approved, deployed and operational radiometry for robotic nondestructive assay (NDA) of holdup deposits in gaseous diffusion piping. Some features, like peak-finding, Compton correction, detector efficiency, and material properties are characteristic of typical manual methods. Most features are specific to in-pipe robotic deployment. These include in-motion radiometry, self-determined location, geometric modeling of thick deposits, bounding of self-attenuation thickness and auto-checking of replicate measurements. Significant are the means for determining all the properties, equations, and constants for automatically computing and displaying all the quantities, uncertainties and information needed for NDA reporting, analysis, and review. Earlier work by this team demonstrated rudimentary but convincing robotic in-pipe NDA of holdup deposits in pipes. Cold testing with high-enrichment mat sources and hot tests with low U-235 loadings together succeeded to exhibit convincing proof-of-principle. This research-grade radiometry implementation lacked accurate odometry, efficiency calibration, high-fidelity detector modeling, attenuation modeling, forward geometric modeling, auto-segmenting, uncertainty modeling, replicate checking, deconvolution and much more. This work explains the technical basis behind robotic in-pipe NDA. It includes discussion of a new method for modeling of self-attenuation using in-pipe deposit geometry information, detail of the method's total measurement uncertainty, and explanation of calibration methods and results. Beyond development of automation-specific radiometric elements, the paper highlights analyses, testing, and technical bases specific to and supportive of the methodology. Examples include collimation characterization, detector efficiency determination, auto-calibration methodology, and odometric replicate-checking. Results of this methodology are formalized in a DOE EM Technical Basis Document, implemented in software, formally verified in review and acceptance testing and proceduralized as a means for D and D NDA at the Portsmouth enrichment facility. Measurement of U-235 quantity is a well-known cost and schedule driver in D and D of every defunct gaseous diffusion enrichment facility in the world. The radiometry methodologies and results detailed in this paper were the high hurdles. Having established the technical basis for this automated NDA, the opportunity is to apply this to many sizes and robot forms for addressing holdup deposit NDA throughout the D and D community. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Magnetic Measurements of Arc Instabilities in Segmented Arc Heater Column

The Aerodynamic Heating Facility (AHF) at NASA Ames Research Center (ARC) generates high enthalpy, supersonic flow environments for ground testing of NASAheat shield materials. This arc jet heater operates by passing a DC arc (<3200A,<2500V) through a gas column (~10cm diameter, 2m length) and ejecting the heatedgas through a supersonic nozzle into a test chamber. The arc plasma is a partially ionized air mixture at low temperature (< 2eV) but needs to be stable for long test times (up to 30min) at high power (< 20MW). Currently, the operational envelope of the facility is limited by arc instabilities including the kink instability. Consequently, it is of interest to characterize these instabilities to better understand facility limits and inform methods to extend stable operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) diagnostics must be non-invasive. This work will cover the development of two sets of magnetic sensors: differential B-dot sensors and tri-axial magnetic hall sensors and will describe initial measurements of arc motion usingthese sensors.

Kink instability↗

OCCAMS: Optically Controlled and Corrected Active Meta-Material Space Structures

Telescopes require sub-wavelength figure (shape) error in order to achieve acceptable Strehl ratios. Traditional methods of achieving this require rigid and therefore heavy mirrors and reaction structures as well as proportionally heavy and expensive spacecraft busses and launch vehicles. This effectively limits the diameter and therefore resolution and collecting area of space optics. Large diameter telescopes must either be heavy or actively controlled. Space telescopes of the size proposed for missions such as TPF (Terrestrial Planet Finder), TPI (Terrestrial Planet Imager), etc. will likely require large active primaries and structures and corrective optics to implement downstream wavefront control. We propose a novel viable enabling technology. High resolution space imaging requires the production of lightweight large aperture optics subject to design tradespace constraints based on nanometer physical tolerances, low system aerial density, high control authority, suitable thermal and mechanical properties, deployment capability, launch vehicle volume constraints, as well as production cost and schedule risk mitigation. Segmented systems impose additional requirements on segment alignment, wavefront phasing, and telescope mass with increased edge diffraction. Photons weigh nothing. Why must even small space telescopes "weigh" tons? Our team is working to demonstrate that they do not, by leveraging 15 years of effort and a novel advanced concept.The ultimate research goal is to refine technology to produce a mission capable ultra-lightweight membrane optic whose shape can be remotely controlled using a laser beam. Using our novel optically-controlled molecular actuators allows substitution of optically-induced control for rigidity and mirror mass. In analogy with noise-canceling headphones, this technique also potentially provides a way to excite vibratory modes to couple with and damp out normal modes of oscillation induced by slewing, other motion and thermal changes, thus allowing a robust response to repointing of a large aperture.

Astronomy↗

Dataset_for_Molecular_Motion_Below_the_Glass_Transition_A_Solid-State_NMR_Study_of_Siloxane_Polymer_Dynamics Study

This dataset contains solid-state 1H and 13C NMR relaxometry data, differential scanning calorimetry (DSC) data, and size exclusion chromatography (SEC/GPC) data supporting the study of sub-glass-transition (sub-Tg) molecular dynamics in a composition- and sequence-controlled series of diphenyl-substituted polysiloxanes (PDMS, 14Ph, 33Ph, 50Ph, 67Ph, and 100Ph; 0–100% diphenylsiloxane content by mole).All solid-state NMR data were acquired on a 200 MHz Bruker Avance III HD spectrometer using a static 7 mm HX probe or a 4 mm HX probe under 4 kHz magic-angle spinning. Raw Bruker TopSpin experiment folders are included for: (1) variable-temperature 1H lineshape measurements used to determine linewidth (FWHM) as a function of temperature across the glass transition; (2) 1H T1 (saturation recovery with solid-echo detection), probing nanosecond-scale dynamics near the 1H Larmor frequency; (3) 1H T1rho (direct spin-lock, 62.5 kHz), probing microsecond-scale segmental dynamics; (4) 13C-detected Lee–Goldburg cross-polarization 1H T1rho (LGCPH T1rho) for 33Ph and 50Ph, resolving aromatic and aliphatic proton environments; and (5) 13C T1 relaxation for 33Ph and 50Ph. Differential scanning calorimetry data (TA Instruments DSC 25, −150 to +120 °C, up to +300 °C for 100Ph, 10 °C/min) are included for all six compositions and support the glass-transition temperatures in Table 1 and Figure 1. Size exclusion chromatography data (Agilent 1200 Series, PL-Gel 300 mixed-C column, THF mobile phase, polystyrene calibration standards) are included for the three synthesized copolymers (33Ph, 50Ph, 67Ph) and support the number-average molecular weights in Table 1. Processed data include per-composition relaxation-time summaries (Excel), curve-fitting and Bloembergen-Purcell-Pound (BPP) model analysis notebooks (Jupyter/Python), and Igor Pro (.pxp) master files used to generate the manuscript's figures.

Bloembergen-Purcell-Pound theory↗

SU-E-T-613: Dosimetric Consequences of Systematic MLC Leaf Positioning Errors

Purpose: The purpose of this study is to determine the dosimetric consequences of systematic MLC leaf positioning errors for clinical IMRT patient plans so as to establish detection tolerances for quality assurance programs. Materials and Methods: Dosimetric consequences were simulated by extracting mlc delivery instructions from the TPS, altering the file by the specified error, reloading the delivery instructions into the TPS, recomputing dose, and extracting dose-volume metrics for one head-andneck and one prostate patient. Machine error was simulated by offsetting MLC leaves in Pinnacle in a systematic way. Three different algorithms were followed for these systematic offsets, and are as follows: a systematic sequential one-leaf offset (one leaf offset in one segment per beam), a systematic uniform one-leaf offset (same one leaf offset per segment per beam) and a systematic offset of a given number of leaves picked uniformly at random from a given number of segments (5 out of 10 total). Dose to the PTV and normal tissue was simulated. Results: A systematic 5 mm offset of 1 leaf for all delivery segments of all beams resulted in a maximum PTV D98 deviation of 1%. Results showed very low dose error in all reasonably possible machine configurations, rare or otherwise, which could be simulated. Very low error in dose to PTV and OARs was shown in all possible cases of one leaf per beam per segment being offset (<1%), or that of only one leaf per beam being offset (<.2%). The errors resulting from a high number of adjacent leaves (maximum of 5 out of 60 total leaf-pairs) being simultaneously offset in many (5) of the control points (total 10–18 in all beams) per beam, in both the PTV and the OARs analyzed, were similarly low (<2–3%). Conclusions: The above results show that patient shifts and anatomical changes are the main source of errors in dose delivered, not machine delivery. These two sources of error are “visually complementary” and uncorrelated (albeit not additive in the final error) and one can easily incorporate error resulting from machine delivery in an error model based purely on tumor motion.

60 APPLIED LIFE SCIENCES↗

Water-Landing Characteristics of a Reentry Capsule

Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.

John R McGehee↗

Water Landing Characteristics of a Reentry Capsule

Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.

John R McGehee↗

Development of a Wide Range Segmented Gamma Scanner for Measuring Radioactive Wastes Arising in the Chinese Nuclear Industry - 16261

There is a requirement to measure a variety of challenging radioactive waste forms generated by the Chinese nuclear industry. These range from low activity waste to high activity waste with a high content of Cs-137 and waste in high density 200 litre drums. This paper describes the design, development and testing of an updated and automated Wide Range Segmented Gamma Scanner (WR-SGS) specifically configured for Chinese nuclear industry radioactive waste measuring requirements. The instrument retains the capabilities of the original SGS developed by Parker and Martin at the Los Alamos National Laboratory and now widely used for radioactive waste assay. It also incorporates additional features to improve measurement efficiency and reduce cost. These features include continuous helical scanning of the waste drum, and separate lifting pillars to lift the detector and the transmission source. In place of a transmission source shutter mechanism, the source is placed in a shielded safe when not in use. The design also incorporates a variable aperture collimator, and tungsten filters that can be deployed for the measurement of high activity, high dose-rate drums. Updated motion control electronics, based on the use of a programed logic controller have been incorporated to address potential future obsolescence. The WR-SGS employs a 40% high purity Germanium detector with electro-mechanical cooling and state of the art digital spectroscopy counting electronics for gamma ray spectrum data acquisition. Testing of the unit has been performed with both point sources and rod sources, which are traceable to international standards. Typical test drums, each with six distributed re-entrant tubes and with different density matrices, have been employed with the rod sources to validate both the calibration and the measurement performance of the WR-SGS for drums of different density. The measurement results have been compared with the reference decay corrected activity values and very good agreement is achieved, confirming the measurement performance of the instrument. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography

BACKGROUND: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. METHODS AND RESULTS: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5-3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. CONCLUSION: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.

Non-NASA Center↗

Magnetic Measurements of Arc Instabilities in Segmented Arc Heater Column

The Aerodynamic Heating Facility (AHF) at NASA Ames Research Center (ARC) generates high enthalpy, supersonic flow environments for ground testing of NASAheat shield materials. This arc jet heater operates by passing a DC arc (<3200 A,<2500 V) through a gas column (~6 cm diameter, 2 m length) and ejecting the heated gas through a supersonic nozzle into a test chamber. The arc plasma is a partially ionized air mixture at low temperature (< 2 eV) but needs to be stable for long test times (up to 30 min) at high power (< 20 MW). Currently, the operational envelope of the facility is limited by arc instabilities including the kink instability. Consequently, it is of interest to characterize these instabilities to better understand facility limits and inform methods to extend stable operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) diagnostics must be non-invasive. This work will cover the development of two sets of magnetic sensors: differential B-dot sensors and tri-axial magnetic hall sensors and will describe initial measurements of arc motion using these sensors.

Kink instability↗

Local variability in the orbit of Saturn's F ring

We present an analysis of the orbit of Saturn's F ring using images recorded by the Imaging Science Subsystem of the Cassini spacecraft. A total of 9805 observations have been made from 10 image sequences obtained between 2006 November 23 and 2009 July 28. Each sequence of up to 240 images spans a single orbit of the F ring, allowing 10 independent high-precision estimates of the ring orbit to be made over this ∼3 year period. The ring has been modeled as an inclined uniformly precessing ellipse. The results show a variability in the orbital elements with, for example, the semi-major axis scattered between 140211.2 ± 0.1 km and 140232.9 ± 0.4 km and the fitted periapses locked to the value obtained from a combined fit using the entire three-year span of observations. We show that the observed scatter between the individual estimates of the ring orbit reflect the differing past histories of the particular segments of ring being fitted and that the values are scattered within the limits expected from a single gravitational encounter with the nearby moon, Prometheus. In the combined fit, the scatter averages out to reveal a small systematic bias with respect to the results of Bosh et al. and Albers et al. We believe this is a consequence of the proximity of Prometheus to the ring in the image sequences chosen for this analysis. Finally, we note a close empirical commensurability between the apsidal precession rate, ϖ-dot , of the F ring and the synodic period between Prometheus and the F ring, such that n {sub Prom} – n {sub Fring} ≈ 2 ϖ-dot {sub Fring}, where n {sub Prom} and n {sub Fring} are the mean motions, and discuss its implications.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-303-08: Direct Lung Tumor Tracking Using Short Imaging Arcs

Purpose: Most current tumor tracking technologies rely on implanted markers, which suffer from potential toxicity of marker placement and mis-targeting due to marker migration. Several markerless tracking methods have been proposed: these are either indirect methods or have difficulties tracking lung tumors in most clinical cases due to overlapping anatomies in 2D projection images. We propose a direct lung tumor tracking algorithm robust to overlapping anatomies using short imaging arcs. Methods: The proposed algorithm tracks the tumor based on kV projections acquired within the latest six-degree imaging arc. To account for respiratory motion, an external motion surrogate is used to select projections of the same phase within the latest arc. For each arc, the pre-treatment 4D cone-beam CT (CBCT) with tumor contours are used to estimate and remove the contribution to the integral attenuation from surrounding anatomies. The position of the tumor model extracted from 4D CBCT of the same phase is then optimized to match the processed projections using the conjugate gradient method. The algorithm was retrospectively validated on two kV scans of a lung cancer patient with implanted fiducial markers. This patient was selected as the tumor is attached to the mediastinum, representing a challenging case for markerless tracking methods. The tracking results were converted to expected marker positions and compared with marker trajectories obtained via direct marker segmentation (ground truth). Results: The root-mean-squared-errors of tracking were 0.8 mm and 0.9 mm in the superior-inferior direction for the two scans. Tracking error was found to be below 2 and 3 mm for 90% and 98% of the time, respectively. Conclusions: A direct lung tumor tracking algorithm robust to overlapping anatomies was proposed and validated on two scans of a lung cancer patient. Sub-millimeter tracking accuracy was observed, indicating the potential of this algorithm for real-time guidance applications.

60 APPLIED LIFE SCIENCES↗

Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring

Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved tumor delineation, and to assess the tumor response in follow-up investigations after or even during the course of fractionated therapy. Moreover, active research is being pursued on new tracers capable of providing different insights into tumor function, in order to identify areas of the planning volume which may require additional dosage for improved probability of tumor control. In this respect, major progresses in the next years will likely concern the development and clinical investigation of novel tracers and image processing techniques for reliable thresholding and segmentation, of treatment planning and beam delivery approaches integrating the PET imaging information, as well as improved multimodal clinical instrumentation such as PET/MR. But especially in the rapidly emerging case of ion beam therapy, the usage of PET is not only limited to the imaging of external tracers injected to the patient. In fact, a minor amount of positron emitters is formed in nuclear fragmentation reactions between the impinging ions and the tissue, bearing useful information for confirmation of the delivered treatment during or after therapeutic irradiation. Different implementations of unconventional PET imaging for therapy monitoring are currently being investigated clinically, and major ongoing research aims at new dedicated detector technologies and at challenging applications such as real-time imaging and time-resolved in vivo verification of motion compensated beam delivery. This paper provides an overview of the different areas of application of PET in radiation oncology and discusses the most promising perspectives in the years to come for radiation therapy planning, delivery, and monitoring.

60 APPLIED LIFE SCIENCES↗

A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min{sup −1}. The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An electromagnetically navigated bronchoscopy system was constructed with accurate registration of an electromagnetic tracker and the CT volume on the basis of an improved marker-free registration approach that uses the bronchial centerlines and bronchoscope tip center information. The fiducial and target registration errors of our electromagnetic navigation system were about 6.6 and 4.5 mm in dynamic bronchial phantom validation.

60 APPLIED LIFE SCIENCES↗

Quantum model of electron accumulation at charged boundaries of heavily doped semiconductor films

A new quantum model of electron accumulation at positively charged boundaries of semiconductor films has been developed. It is based on the well-known concepts of quantum confinement of transverse electron motion in a uniform electric field, the role of which is played by the effective field of attraction to positive surface donor centers. Electrons with a surface density equal to the donor concentration occupy the corresponding quasi-discrete states according to the Fermi statistics. At reasonable concentrations all the electrons of the accumulation layer are mainly concentrated at the first quantum-confinement level. Ultra-high built-in fields on the order of the atomic level (10{sup 8} V/cm) correspond to the onset of filling the third level. The potential profile, which describes the interaction of the accumulation-layer electrons with other charged particles (including holes) is calculated by double integration of the Poisson equation with the electron density in the form of squares of the corresponding segments of the Airy function. Its boundary value-the surface potential-describes the effect of the electron-accumulation layer on the external electric circuit. The obtained dependence of the surface potential on the resulting boundary electric field (including that induced by the built-in charge) is easily transformed into the corresponding capacitance-voltage characteristics.

36 MATERIALS SCIENCE↗