Search NASA⌕ Search

SEARCH · Search NASA

Results for “Normalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Pitfalls in Prediction Modeling for Normal Tissue Toxicity in Radiation Therapy: An Illustration With the Individual Radiation Sensitivity and Mammary Carcinoma Risk Factor Investigation Cohorts

Purpose: To identify the main causes underlying the failure of prediction models for radiation therapy toxicity to replicate. Methods and Materials: Data were used from two German cohorts, Individual Radiation Sensitivity (ISE) (n=418) and Mammary Carcinoma Risk Factor Investigation (MARIE) (n=409), of breast cancer patients with similar characteristics and radiation therapy treatments. The toxicity endpoint chosen was telangiectasia. The LASSO (least absolute shrinkage and selection operator) logistic regression method was used to build a predictive model for a dichotomized endpoint (Radiation Therapy Oncology Group/European Organization for the Research and Treatment of Cancer score 0, 1, or ≥2). Internal areas under the receiver operating characteristic curve (inAUCs) were calculated by a naïve approach whereby the training data (ISE) were also used for calculating the AUC. Cross-validation was also applied to calculate the AUC within the same cohort, a second type of inAUC. Internal AUCs from cross-validation were calculated within ISE and MARIE separately. Models trained on one dataset (ISE) were applied to a test dataset (MARIE) and AUCs calculated (exAUCs). Results: Internal AUCs from the naïve approach were generally larger than inAUCs from cross-validation owing to overfitting the training data. Internal AUCs from cross-validation were also generally larger than the exAUCs, reflecting heterogeneity in the predictors between cohorts. The best models with largest inAUCs from cross-validation within both cohorts had a number of common predictors: hypertension, normalized total boost, and presence of estrogen receptors. Surprisingly, the effect (coefficient in the prediction model) of hypertension on telangiectasia incidence was positive in ISE and negative in MARIE. Other predictors were also not common between the 2 cohorts, illustrating that overcoming overfitting does not solve the problem of replication failure of prediction models completely. Conclusions: Overfitting and cohort heterogeneity are the 2 main causes of replication failure of prediction models across cohorts. Cross-validation and similar techniques (eg, bootstrapping) cope with overfitting, but the development of validated predictive models for radiation therapy toxicity requires strategies that deal with cohort heterogeneity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods for Reducing Normal Tissue Complication Probabilities in Oropharyngeal Cancer: Dose Reduction or Planning Target Volume Elimination

Purpose: Strategies to reduce the toxicities of head and neck radiation (ie, dysphagia [difficulty swallowing] and xerostomia [dry mouth]) are currently underway. However, the predicted benefit of dose and planning target volume (PTV) reduction strategies is unknown. The purpose of the present study was to compare the normal tissue complication probabilities (NTCP) for swallowing and salivary structures in standard plans (70 Gy [P70]), dose-reduced plans (60 Gy [P60]), and plans eliminating the PTV margin. Methods and Materials: A total of 38 oropharyngeal cancer (OPC) plans were analyzed. Standard organ-sparing volumetric modulated arc therapy plans (P70) were created and then modified by eliminating the PTVs and treating the clinical tumor volumes (CTVs) only (C70) or maintaining the PTV but reducing the dose to 60 Gy (P60). NTCP dose models for the pharyngeal constrictors, glottis/supraglottic larynx, parotid glands (PGs), and submandibular glands (SMGs) were analyzed. The minimal clinically important benefit was defined as a mean change in NTCP of >5%. The P70 NTCP thresholds and overlap percentages of the organs at risk with the PTVs (56-59 Gy, vPTV{sub 56}) were evaluated to identify the predictors for NTCP improvement. Results: With the P60 plans, only the ipsilateral PG (iPG) benefited (23.9% vs 16.2%; P<.01). With the C70 plans, only the iPG (23.9% vs 17.5%; P<.01) and contralateral SMG (cSMG) (NTCP 32.1% vs 22.9%; P<.01) benefited. An iPG NTCP threshold of 20% and 30% predicted NTCP benefits for the P60 and C70 plans, respectively (P<.001). A cSMG NTCP threshold of 30% predicted for an NTCP benefit with the C70 plans (P<.001). Furthermore, for the iPG, a vPTV{sub 56} >13% predicted benefit with P60 (P<.001) and C70 (P=.002). For the cSMG, a vPTV{sub 56} >22% predicted benefit with C70 (P<.01). Conclusions: PTV elimination and dose-reduction lowered the NTCP of the iPG, and PTV elimination lowered the NTCP of the cSMG. NTCP thresholds and the percentage of overlap of the PTV with organs at risk can predict which patients will benefit and inform future clinical trial design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Normal Tissue Response of Combined Temporal and Spatial Fractionation in Proton Minibeam Radiation Therapy

Proton minibeam radiation therapy, a spatial fractionation concept, widens the therapeutic window. By reducing normal tissue toxicities, it allows a temporally fractionated regime with high daily doses. However, an array shift between daily fractions can affect the tissue-sparing effect by decreasing the total peak-to-valley dose ratio. Therefore, combining temporal fractions with spatial fractionation raises questions about the impact of daily applied dose modulations, reirradiation accuracies, and total dose modulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultra-high-dose-rate FLASH and Conventional-Dose-Rate Irradiation Differentially Affect Human Acute Lymphoblastic Leukemia and Normal Hematopoiesis

Ultra-high-dose-rate FLASH radiation therapy has been shown to minimize side effects of irradiation in various organs while keeping antitumor efficacy. This property, called the FLASH effect, has caused enthusiasm in the radiation oncology community because it opens opportunities for safe dose escalation and improved radiation therapy outcome. Here, we investigated the impact of ultra-high-dose-rate FLASH versus conventional-dose-rate (CONV) total body irradiation (TBI) on humanized models of T-cell acute lymphoblastic leukemia (T-ALL) and normal human hematopoiesis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasound-Mediated Gemcitabine Delivery Reduces the Normal-Tissue Toxicity of Chemoradiation Therapy in a Muscle-Invasive Bladder Cancer Model

Chemoradiation therapy is the standard of care in muscle-invasive bladder cancer (MIBC). Although agents such as gemcitabine can enhance tumor radiosensitivity, their side effects can limit patient eligibility and treatment efficacy. This study investigates ultrasound and microbubbles for targeting gemcitabine delivery to reduce normal-tissue toxicity in a murine orthotopic MIBC model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Salivary and Dental Complications in Childhood Cancer Survivors Treated With Radiation Therapy to the Head and Neck: A Pediatric Normal Tissue Effects in the Clinic (PENTEC) Comprehensive Review

Radiation therapy (RT) to the head and neck (H&N) region is critical in the management of various pediatric malignancies; however, it may result in late toxicity. This comprehensive review from the Pediatric Normal Tissue Effects in the Clinic (PENTEC) initiative focused on salivary dysfunction and dental abnormalities in survivors who received RT to the H&N region as children.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Normal Tissue Complication Probability (NTCP) Prediction Model for Osteoradionecrosis of the Mandible in Patients With Head and Neck Cancer After Radiation Therapy: Large-Scale Observational Cohort

Osteoradionecrosis (ORN) of the mandible represents a severe, debilitating complication of radiation therapy (RT) for head and neck cancer (HNC). At present, no normal tissue complication probability (NTCP) models for risk of ORN exist. The aim of this study was to develop a multivariable clinical/dose-based NTCP model for the prediction of ORN any grade (ORN{sub I-IV}) and grade IV (ORN{sub IV}) after RT (±chemotherapy) in patients with HNC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irradiation at Ultra-High (FLASH) Dose Rates Reduces Acute Normal Tissue Toxicity in the Mouse Gastrointestinal System

Preclinical studies using ultra-high dose rate (FLASH) irradiation have demonstrated reduced normal tissue toxicity compared with conventional dose rate (CONV) irradiation, although this finding is not universal. We investigated the effect of temporal pulse structure and average dose rate of FLASH compared with CONV irradiation on acute intestinal toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How to normalize Maxwell-Boltzmann electrons in transient plasma models

Proper normalization of a Maxwell-Boltzmann electron distribution in transient plasma models requires the self-consistent calculation of a reference density from a global electron conservation equation. This calculation tends to produce numerical oscillations in the time evolution of the plasma, in particular during the formation of the plasma sheath. The present paper proposes a simple numerical scheme to prevent these oscillations by artificial critical damping, which makes it possible to simulate transient plasma phenomena without electron-related time step conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonhuman biota dose rate estimation from liquid effluent releases during normal operations of light water reactors using the LADTAP II computer code

Here, the LADTAP II computer code was used to estimate the dose rates to seven nonhuman biota (fish, algae, invertebrate, muskrat, raccoon, heron, and duck) from liquid effluent releases during the normal operations of new light water reactor facilities in the United States. The estimated dose rates to nonhuman biota depended on the nuclear power plant design but were orders of magnitude less than the ‘derived consideration reference levels’ (DCRL) in International Commission on Radiological Protection (ICRP) Publication 108. The estimated dose rates were at least three orders of magnitude lower than the guideline values identified by the International Atomic Energy Agency (IAEA) and the National Council on Radiation Protection and Measurements to cause observable changes in populations of biota. Radionuclides that contributed most of the dose rates for seven nonhuman biota depended on the nuclear power plant design. The differences in the estimated dose rates to seven nonhuman biota calculated from the default bioaccumulation factors used in the LADTAP II computer code and the dose rates calculated from the concentration ratios of radionuclides in the IAEA Technical Report Series (TRS) wildlife handbook were less than one order of magnitude for most default biota in LADTAP. The concentration ratios for some radionuclides in liquid effluent releases from nuclear power plant designs that contributed more than 5% of the internal dose rates for invertebrates (P, and Ru) and algae (La and Pr) were not available in the IAEA TRS wildlife handbook.

54 ENVIRONMENTAL SCIENCES↗

Performance of U 3 Si 2 in an LWR following a cladding breach during normal operation

High-density fuels have been proposed as a possible replacement for uranium-dioxide as a fuel for light water reactors (LWRs) due to their increased loading of fissionable material. The objectives of this proposal are (1) to increase reactor cycle length and reactor power, and (2) to offset any neutronic penalty associated with advanced cladding systems. Of the high-density fuels under consideration, there is particular interest in triuranium disilicide (U 3 Si 2 ) due to its increased metal density and favorable thermal properties as compared to UO 2 . However, there are concerns regarding the chemical compatibility of U 3 Si 2 with water and steam as used for LWR coolant.This paper summarizes research on fuel-coolant chemical compatibility for UO 2 LWR fuel during a cladding breach and highlights that generally, because of its chemical inertness, UO 2 -coolant reactions are of little consequence to reactor operation. However, the volumetric expansion associated with the reaction of UO 2 and oxygen is a concern for possible conditions encountered during air ingress of dry storage. These same concerns arise for U 3 Si 2 , which exhibits greater volumetric expansion than UO 2 when exposed to water or steam. These reactions ultimately result in increased fuel volume that the cladding must accommodate, as well as additional heat generated as the fuel reacts.The BISON fuel performance code was used to perform a comparative analysis on the behavior of UO 2 and U 3 Si 2 under normal operation. Silicide fuel simulations were then extended to demonstrate how varying thermodynamic and chemical kinetics influence fuel expansion and subsequent cladding performance during a cladding breach. These simulations were further extended to a 3D subsection of a fuel rod to demonstrate the characteristics of the resulting cladding crack.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Locating the normal to relaxor phase boundary in Ba(Ti{sub 1-x}Hf{sub x})O{sub 3} ceramics

In this article, we report our studies on the relaxor behavior of Ba(Ti{sub 1-x}Hf{sub x})O{sub 3} ceramics, made with close compositions between 0.20 {<=} x {<=} 0.30, to locate the hafnium concentration boundary for the normal to relaxor crossover. X-ray diffraction followed by Rietveld refinement shows the occurrence of single-phase cubic structure for the synthesized Ba(Ti{sub 1-x}Hf{sub x})O{sub 3} ceramics. Temperature and frequency dependence of the real ({epsilon}') and imaginary ({epsilon}'') parts of the dielectric permittivity has been studied in the temperature range of 90-350 K at frequencies of 0.1, 1, 10, and 100 kHz. A diffuse phase transition accompanying frequency dispersion is observed in the permittivity versus temperature plots revealing the occurrence of relaxor ferroelectric behavior. The T{sub m} verses Hf concentration plot shows a discontinuous jump and change in the slope at x = 0.23. Quantitative characterization based on phenomenological models has also been presented. The plausible mechanism of the relaxor behavior has been discussed. Substitution of Hf{sup 4+} for Ti{sup 4+} in BaTiO{sub 3} reduces the long-range polar ordering yielding a diffuse ferroelectric phase transition.

36 MATERIALS SCIENCE↗

Simulation of Dose to Surrounding Normal Structures in Tangential Breast Radiotherapy Due to Setup Error

Setup error plays a significant role in the final treatment outcome in radiotherapy. The effect of setup error on the planning target volume (PTV) and surrounding critical structures has been studied and the maximum allowed tolerance in setup error with minimal complications to the surrounding critical structure and acceptable tumor control probability is determined. Twelve patients were selected for this study after breast conservation surgery, wherein 8 patients were right-sided and 4 were left-sided breast. Tangential fields were placed on the 3-dimensional-computed tomography (3D-CT) dataset by isocentric technique and the dose to the PTV, ipsilateral lung (IL), contralateral lung (CLL), contralateral breast (CLB), heart, and liver were then computed from dose-volume histograms (DVHs). The planning isocenter was shifted for 3 and 10 mm in all 3 directions (X, Y, Z) to simulate the setup error encountered during treatment. Dosimetric studies were performed for each patient for PTV according to ICRU 50 guidelines: mean doses to PTV, IL, CLL, heart, CLB, liver, and percentage of lung volume that received a dose of 20 Gy or more (V20); percentage of heart volume that received a dose of 30 Gy or more (V30); and volume of liver that received a dose of 50 Gy or more (V50) were calculated for all of the above-mentioned isocenter shifts and compared to the results with zero isocenter shift. Simulation of different isocenter shifts in all 3 directions showed that the isocentric shifts along the posterior direction had a very significant effect on the dose to the heart, IL, CLL, and CLB, which was followed by the lateral direction. The setup error in isocenter should be strictly kept below 3 mm. The study shows that isocenter verification in the case of tangential fields should be performed to reduce future complications to adjacent normal tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Obtaining Normal Tissue Constraints Using Intensity Modulated Radiotherapy (IMRT) in Patients with Oral Cavity, Oropharnygeal, and Laryngeal Carcinoma

The purpose of this study was to evaluate normal tissue dose constraints while maintaining planning target volume (PTV) prescription without reducing PTV margins. Sixteen patients with oral cavity carcinoma (group I), 27 patients with oropharyngeal carcinoma (group II), and 28 patients with laryngeal carcinoma (group III) were reviewed. Parotid constraints were a mean dose to either parotid < 26 Gy (PP1), 50% of either parotid < 30 Gy (PP2), or 20 cc of total parotid < 20 Gy (PP3). Treatment was intensity modulated radiation therapy (IMRT) with simultaneous integrated boost (SIB). All patients met constraints for cord and brain stem. The mandibular constraints were met in 66%, 29%, and 57% of patients with oral, oropharyngeal, and laryngeal cancers, respectively. Mean dose of 26 Gy (PP1) was achieved in 44%, 41%, and 38% of oral, oropharyngeal, and laryngeal patients. PP2 (parotid constraint of 30 Gy to less than 50% of one parotid) was the easiest to achieve (group I, II, and III: 82%, 76%, and 78%, respectively). PP3 (20 cc of total parotid < 20 Gy) was difficult, and was achieved in 25%, 17%, and 35% of oral, oropharyngeal, and laryngeal patients, respectively. Mean parotid dose of 26 Gy was met 40% of the time. However, a combination of constraints allowed for sparing of the parotid based on different criteria and was met in high numbers. This was accomplished without reducing PTV-parotid overlap. What dose constraint best correlates with subjective and objective functional outcomes remains a focus for future study.

61 RADIATION PROTECTION AND DOSIMETRY↗