Measurement-Based Approach for Inertia-Trend Analysis of the US Western Interconnection

Rising deployment of inverter-based resources (IBRs), characterized by a lack of rotating mass, is decreasing the total inertia of the system. This can lead to an increased Rate of Change of Frequency (RoCoF) during the disturbance and false activation of protective devices. There is a need to assess the inertia over the past decade amidst the evolving landscape of renewable energy sources to develop strategies for integrating energy storage, enhancing resilience measures, and ensuring the stable and reliable operation of the grid. Therefore, a realistic assessment of the inertia trend using a measurement-based approach that addresses the limitations of existing models is proposed. An inertia study of the Western Interconnection in the United States is performed utilizing the data from 2013 to 2022, obtained from FNET/ GridEye network. The three-second RoCoF time window is chosen for the study as it showed an optimum balance between a strong correlation with the power imbalance (ΔP) and minimum inclusion of primary response from governor. The obtained inertia trend result shows a small percentage declination of inertia over the decade. By examining the result alongside a generation mix graph, insights are gained into the dynamic interplay between shifting energy landscape and system inertia.

Dulal, Saurav↗

Fault Detection via Occupation Kernel Principal Component Analysis

Reliable operation of automatic systems is heavily dependent on the ability to detect faults in the underlying dynamics. While traditional model-based methods have been widely used for fault detection, data-driven approaches have garnered increasing attention due to their ease of deployment and minimal need for expert knowledge. In this letter, we present a novel principal component analysis (PCA) method that uses occupation kernels. Occupation kernels result in feature maps that are tailored to the measured data, have inherent noise-robustness due to the use of integration, and can utilize irregularly sampled system trajectories of variable lengths for PCA. The occupation kernel PCA method is used to develop a reconstruction error approach to fault detection and its efficacy is validated using numerical simulations.

42 ENGINEERING↗

A Game Changer: Electrifying Remote Communities by Using Isolated Microgrids

Microgrids, as self-contained entities, are of increasing interest in modern electric grids. Microgrids provide a sustainable solution to aggregate distributed energy resources (DERs) [e.g., photovoltaics (PVs), wind turbines], energy storage, and loads in a localized manner, especially in distribution systems. As a controllable unit, a microgrid can manage and balance the source and load power inside it to ensure stable and reliable operation. Moreover, through coordination with upper-level control systems, it can be dispatched and respond to the control commands issued by the central controller in the distribution system-in other words, a system that is effectively a distribution management system (DMS).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flexibility from Energy Systems Integration: Supporting Synergies Among Sectors

Energy systems integration, or sector coupling, has several drivers that span climate impact mitigation and economics to social and regulatory considerations. A key question is what is sector coupling, and how does it impact the flexibility of the energy system? Here, the energy system includes several sectors - electricity, gas, heat, and transportation - that have been independent for decades in most countries except for their coupling via combined heat and power (CHP) units. In energy systems integration, some sectors may provide flexibility to other sectors, while other sectors will require flexibility when interlinking. To support these synergies among sectors, it is important to explore and quantify mutual interactions as well as seek examples of how these integrations can provide flexibility and other benefits. From the perspective of the electricity sector, it is important to ensure that there is enough flexibility in the interconnected systems to support decarbonization goals, such as those set in the Paris Agreement, while ensuring operational reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiple Linear Regression Based Disturbance Magnitude Estimations for Bulk Power Systems

Sudden trips of generation or large system load threaten bulk power systems (BPSs) secure and reliable operations. With the increasing deployment of Phasor Measurements Units (PMUs), system operators are thrilled to receive instant notifications of sudden disturbances and be aware of where, when, and what type of disturbances the system is experiencing. The amount of power imbalance is one of the fundamental information of the interests of both system operators and academic researchers. The PMU-based applications estimate the magnitude by interpreting the dynamic frequency responses immediately after a disturbance occurrence. However, the accuracy of the traditional method is unsatisfying because it oversimplifies the relation between the imbalance magnitude and the frequency response. This paper proposes to estimate the magnitudes of power imbalances based on multiple linear regression. It considers several other system and environmental factors and identifies those factors strongly associated with the disturbance magnitude. The approach is applied to actual generation trip events happened in two of the main power grids in North America. Compared with the traditional method, the proposed approach demonstrates improved accuracy.

Wu, Ling↗

Hardware-in-the-Loop (HIL) Simulations for Smart Grid Impact Studies

Hardware-in-the-loop (HIL) simulations are increasingly employed in power engineering as more inverter-based generation and smart appliances are connected to the electric grid. HIL techniques allow for the co-simulation of analytical models with actual devices whose complex behavior is computationally inefficient or difficult to model. They also allow for testing the behavior of these devices under adverse conditions that rarely occur in the field but are important to evaluate. This paper provides an overview of how HIL simulations have been used to date and proposes that HIL simulations should play an important role in evaluating new control strategies, especially at the distribution level, that are being proposed to allow for continued affordable and reliable operation of the electric grid. We present a new capability that was developed to evaluate the interactions between residential loads and the smart grid: smart home hardware-in-the-loop. The paper includes results from an HIL experiment that incorporates multiple technologies and controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Synchrophasors to Improve Bulk Power System Reliability in North America

Maintaining reliable operation of the bulk power system is a fundamental aspect of grid operation, and focuses on ensuring the system can withstand sudden disturbances or unanticipated failures of system elements such that instability, uncontrolled separation, or cascading failures will not occur. Phasor measurement units (PMUs) provide the capability for enhanced real-time monitoring and control room solutions as well as improved power system analysis in the planning horizon. With over 1,700 PMUs deployed in the North American grid, numerous PMU-based applications have been developed. This paper summarizes synchrophasor-based applications and presents utility synchrophasor experience.

PMU, oscillation monitoring, Power Plant Model Val↗

Dynamic Parameter Estimation with Physics-based Neural Ordinary Differential Equations

Accurate estimation of dynamic parameters of gen-erators is crucial to building a reliable model for dynamical studies and reliable operation of the power system. This paper develops a physics-based neural ordinary differential equations (ODE) approach to learn the parameters of generator dynamic model using phasor measurement units (PMU) data. We design a physics-based neural network to represent the swing equations of the power system dynamics. A loss function is defined as the difference between dynamic simulation results from the physics-based neural networks and pseudo PMU measurements. The parameters of generator dynamic model are iteratively updated using the neural ODEs and the adjoint method. By exploiting the mini-batch scheme in neural ODE training, the parameter estimation performance is significantly improved. Numerical study results on a 3-machine 9-bus system show that the proposed algorithm outperforms state-of-the-art baseline method in both computation time and dynamic parameter estimation accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

Characterization of a Low-Cost Multi-Parameter Sensor for Solar Resource Applications

Low-cost multi-parameter sensing and measurement devices enable cost-effective monitoringof the functional, operational reliability, efficiency, and resiliency of the electrical grid.The National Renewable Research Laboratory (NREL) Solar Radiation Research Laboratory (SRRL), in collaboration with Arable Labs Inc., deployed Arable Lab's Mark multi-parameter sensor system. The unique suite of system sensors measures the downwelling and upwelling shortwave solar resource and longwave radiation, humidity, air temperature, and ground temperature. This studydescribes the shortwave calibration, characterization, and validation of measurement accuracy of this instrument by comparison with existing instruments that are part of NREL-SRRL's Baseline Measurement System.

14 SOLAR ENERGY↗

Testbed-based Performance Evaluation of Attack Resilient Control for AGC

The modern electric power grid is a complex cyber-physical system whose reliable operation is enabled by a wide-area monitoring and control infrastructure. This infrastructure, supported by an extensive communication backbone, enables several control applications functioning at multiple time scales to ensure the grid is maintained within stable operating limits. Recent events have shown that vulnerabilities in this infrastructure may be exploited to manipulate the data being exchanged. Such a scenario could cause the associated control application to mis-operate, potentially causing system-wide instabilities. There is a growing emphasis on looking beyond traditional cybersecurity solutions to mitigate such threats. In this paper we perform a testbed-based validation of one such solution - Attack Resilient Control (ARC) - on Iowa State University's \textit{PowerCyber} testbed. ARC is a cyber-physical security solution that combines domain-specific anomaly detection and model-based mitigation to detect stealthy attacks on Automatic Generation Control (AGC). In this paper, we first describe the implementation architecture of the experiment on the testbed. Next, we demonstrate the capability of stealthy attack templates to cause forced under-frequency load shedding in a 3-area test system. We then validate the performance of ARC by measuring its ability to detect and mitigate these attacks. Our results reveal that ARC is efficient in detecting stealthy attacks and enables AGC to maintain system operating frequency close to its nominal value during an attack. Our studies also highlight the importance of testbed-based experimentation for evaluating the performance of cyber-physical security and control applications.

attack resilience↗

A Comprehensive Model for Analyzing the Effects of Power Outages on Customers

Power outages can cause significant inconveniences to critical services and substantial economic losses. Therefore, it is crucial to systematically analyze the impact on customers during power outages caused by various factors, such as severe thunderstorms, floods, vegetation, or mechanical problems, and to plan for reliable operation and control under such events. Power outages in different locations may exhibit varying characteristics regarding customer impact. In this paper, we present a mathematical model that captures the essential characteristics of customer impact during power outages. The parameters of our model include impact duration, recovery duration, maximum impact level, increase curve parameter, and decrease curve parameter. We demonstrate how historical power outage data can be fitted to our model, enabling a systematic comparison of outages caused by different factors in various locations.

Lee, Sangkeun (Matt) [ORNL] (ORCID:000000021317511↗

Design, Fabrication, and Testing of a 1.9 m Long, 16.5 mm Period NbTi Superconducting Undulator for the Advanced Photon Source Upgrade

Superconducting undulator (SCU) technology has been in use at the Advanced Photon Source since 2013. Due to the successful and reliable operation of the existing SCUs, the Advanced Photon Source upgrade project has decided to expand the use of NbTi-based SCUs. The first new magnets to be designed and fabricated are 1.9 m long with a period length of 16.5 mm. NbTi superconductor is used for coil winding and there are four separate coils wound on the mandrel to produce the main undulator field along with end compensation and distributed dipole compensation. The magnetic design, fabrication details, assembly, and testing are described in detail.

NbTi.↗

Trust Model Measurements for the Energy Grid of Things

Information security is essential for the reliable operation of an Energy Grid of Things (EGoT). In addition to basic information security protocols as defined by published standards, there is a need for a monitoring function that measures the trustworthiness of the various actors participating in an EGoT. We describe in this paper the implementation and evaluation of a Distributed Trust Model that was developed specifically for monitoring communication within an EGoT. We then show how the model parameters are set using statistical measures for hypothesis testing.

Energy Grid of Things, EGoT, Smart Grid Security, ↗

Equity in Transactive Energy Systems

Transactive energy (TE) research primarily focuses on efficient and reliable operation of the electricity grid by using economic or market-based constructs to incorporate significant amounts of responsive, demand-side assets. This research examines the literature to evaluate if the design of TE demonstrations incorporates microeconomic principles of equity and fairness. We also consider the extent to which the design and implementation of TE affects energy inequities, and how these inequities could be addressed in future research with specific equity valuation metrics. The design of TE systems can impact energy equity across several dimensions and we provide recommendations for incorporating microeconomic principles of equity and fairness in TE system architecture as well as metrics for improving equitable outcomes in TE system design, implementation, and performance.

Energy, Transactive Energy, Economics↗

Testing of a Line Driver With Configurable Pre-Emphasis on Lossy Transmission Lines

Rare-event physics experiments such as the Deep Underground Neutrino Experiment (DUNE) or the next Enriched Xenon Observatory (nEXO) experiment search for rare, low-energy events, detected by sensitive detectors immersed in a cryogenic noble liquid (e.g., liquid argon or xenon). Readout electronics used within such detectors must consume minimal power while operating reliably in cryogenic environments. Furthermore, in the case of nEXO, maximizing the radiopurity of the environment is vital to minimize background noise, thus placing strict limits on the volume of dielectric materials, leading to high-loss data cables spanning distances up to 12 m. Such cables cause high attenuation and intersymbol interference (ISI), resulting in a high bit-error rate (BER). These issues were addressed by developing an integrated line driver with configurable pre-emphasis in a 65-nm CMOS process. The pre-emphasis parameters can be programmed to minimize BER for specific cables and data rates under power constraints. Here, the driver was tested at both room and cryogenic temperatures. In both cases, the output BER was found to be strongly correlated with the pre-emphasis settings. Furthermore, analysis and simulation showed that adapting the pre-emphasis settings based on the incoming bit sequence can further improve performance with minimal changes to the current solution.

47 OTHER INSTRUMENTATION↗

Flux Balancing Control of Ungapped Nanocrystalline Core-Based Transformer in Dual Active Bridge Converters

Transformer flux dc bias is a critical issue, impacting the reliable operation of dual active bridge (DAB) converters especially when ungapped high permeability nanocrystalline core is used. Steady state current dc bias can easily saturate ungapped nanocrystalline transformers, and it is even more dangerous in transient conditions. A dc bias model is proposed to analyze steady state dc bias in different load conditions. The magnetizing current detection is necessary for closed-loop control of dc bias; conductors' position is shown to impact sensor noise, and it is analyzed in detail. To deal with both steady state and transient dc bias, a unified flux balancing control (UFBC) is proposed introducing a predictive bias suppression (PBS) method with closed-loop flux balancing control (CFBC). With the proposed PBS, both primary/secondary current balance and flux balance can be achieved within one switching cycle using UFBC. Power characteristics and interaction between power control and flux balancing control of DAB converters are analyzed, and the CFBC needs to work in a low bandwidth due to sensor bandwidth limitation and interaction between power control and flux balancing control. Lastly, the UFBC is verified on a 300-kW cascaded DAB converter prototype.

42 ENGINEERING↗