At least 613 records · Page 34

New Soft X-ray Beamline (BL10) at the SAGA Light Source

A new soft X-ray beamline (BL10) at the SAGA Light Source (SAGA-LS) was constructed at the end of 2008. Commissioning of this new beamline started at the beginning of 2009. Synchrotron radiation from a variably polarizing undulator (APPLE-II) can be used in this beamline. The obtained light is monochromatized by a varied-line-spacing plane grating monochromator with the variable included angle mechanism. Its designed resolving power and photon flux are 3,000-10,000 and 10{sup 12}-10{sup 9} photons/s at 300 mA, respectively. The performance test results were generally satisfactory. An overview of the optical design of the beamline and the current status of commissioning are reported.

43 PARTICLE ACCELERATORS↗

Ionization Cooling using Parametric Resonances

Ionization Cooling using Parametric Resonances was an SBIR project begun in July 2004 and ended in January 2008 with Muons, Inc., (Dr. Rolland Johnson, PI), and Thomas Jefferson National Accelerator Facility (JLab) (Dr. Yaroslav Derbenev, Subcontract PI). The project was to develop the theory and simulations of Parametric-resonance Ionization Cooling (PIC) so that it could be used to provide the extra transverse cooling needed for muon colliders in order to relax the requirements on the proton driver, reduce the site boundary radiation, and provide a better environment for experiments. During the course of the project, the theoretical understanding of PIC was developed and a final exposition is ready for publication. Workshops were sponsored by Muons, Inc. in May and September of 2007 that were devoted to the PIC technique. One outcome of the workshops was the interesting and somewhat unexpected realization that the beam emittances using the PIC technique can get small enough that space charge forces can be important. A parallel effort to develop our G4beamline simulation program to include space charge effects was initiated to address this problem. A method of compensating for chromatic aberrations by employing synchrotron motion was developed and simulated. A method of compensating for spherical aberrations using beamline symmetry was also developed and simulated. Different optics designs have been developed using the OptiM program in preparation for applying our G4beamline simulation program, which contains all the power of the Geant4 toolkit. However, no PIC channel design that has been developed has had the desired cooling performance when subjected to the complete G4beamline simulation program. This is believed to be the consequence of the difficulties of correcting the aberrations associated with the naturally large beam angles and beam sizes of the PIC method that are exacerbated by the fringe fields of the rather complicated channel designs that have been attempted. That is, while the designs developed and tested using the matrix program OptiM can work well, a real simulation with lumped dipoles, quadrupoles, and solenoids and their associated fringe fields has not succeeded. As a consequence of this realization, a new approach is being attempted that is based on the use of a helical solenoid (HS) channel that is made of simple coils that provide a much more homogeneous magnetic field. However, in order to use the HS a new approach was required to generate a variable dispersion that is needed according to the PIC theory described above. This approach and its first implementation will be described at EPAC08 in June, 2008.

43 PARTICLE ACCELERATORS↗

Design considerations for AIRES, an airborne infrared echelle spectrometer for SOFIA

The airborne infrared echelle spectrometer (AIRES) was proposed as a facility instrument for the stratospheric observatory for infrared astronomy (SOFIA) project. The preliminary AIRES design uses multiple two dimensional detector arrays and a 1.2 m long, 76 deg blaze angle echelle to combine high spectral resolution with diffraction limited imaging in the cross-dispersion direction. A preliminary optical design and the mechanical architecture are presented together with the analysis and prototyping of lightweight aluminum echelles. Instrument efficiencies are calculated and compared for different gratings, and the associated mechanical design tradeoffs are discussed.

Haas, Michael R.↗

The Primordial Inflation Explorer (PIXIE)

The Primordial Inflation Explorer is an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. PIXIE uses an innovative optical design to achieve background-limited sensitivity in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded non-imaging optics feed a polarizing Fourier Transform Spectrometer to produce a set of interference fringes, proportional to the difference spectrum between orthogonal linear polarizations from the two input beams. Multiple levels of symmetry and signal modulation combine to reduce the instrumental signature and confusion from unpolarized sources to negligible levels. PIXIE will map the full sky in Stokes I, Q, and U parameters with angular resolution 2.6 deg and sensitivity 0.2 μK per 1 deg square pixel. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r less than 10(exp −3) at 5 standard deviations. In addition, PIXIE will measure the absolute frequency spectrum to constrain physical processes ranging from inflation to the nature of the first stars to the physical conditions within the interstellar medium of the Galaxy. We describe the PIXIE instrument and mission architecture with an emphasis on the expected level of systematic error suppression.

Primordial Inflation Explorer is an Explorer-class↗

Achromat Design for Multi-Pulse Test Line

This note describes the design of a 90° achromatic bend on DARHT Axis 2 to support multi-pulse target studies. The achromatic bend consists of two 45° dipole magnets with a focusing quadrupole centered between the dipoles. The optical design of the achromat is described followed by a discussion of the sensitivity to space charge and variations in the beam energy. The preliminary design of the magnets is then described with a description of the electro-mechanical parameters.

42 ENGINEERING↗

Wideband comet camera lens design

A quarter-meter diameter, modified Ritchey-Chretien camera is described for spacecraft-based observation of Halley's Comet. The system will operate over an unusually broad spectral region, from 0.1216 micron (the hydrogen Lyman-alpha line) to 1.1 microns using reflective primary and secondary mirror optics and a thin UV-grade lithium fluoride refractive element as a field corrector near the image plane. The f/12, 3000 mm focal length camera has a 0.4 deg full field of view for operation with a 15 x 15 mm charge-coupled device detector array. The UV-enhanced silicon CCD detector is a 1000 x 1000 array of 15 micron pixels which establishes the system resolution requirement. The optical design and performance are discussed, with an emphasis on the image analysis with respect to pixel resolution elements used for viewing extended objects such as comets.

Huber, E. D.↗

Optical Alignment and Diffraction Analysis for AIRES: An Airborne Infrared Echelle Spectrometer

The optical design is presented for a long-slit grating spectrometer known as AIRES (Airborne InfraRed Echelle Spectrometer). The instrument employs two gratings in series: a small order sorter and a large steeply blazed echelle. The optical path includes four pupil and four field stops, including two narrow slits. A detailed diffraction analysis is performed using GLAD by Applied Optics Research to evaluate critical trade-offs between optical throughput, spectral resolution, and system weight and volume. The effects of slit width, slit length, oversizing the second slit relative to the first, on- vs off-axis throughput, and clipping at the pupil stops and other optical elements are discussed.

Haas, Michael R.↗

The Primordial Inflation Explorer (PIXIE)

The Primordial Inflation Explorer is an Explorer-class mission to open new windows on the early universe through measurements of the polarization and absolute frequency spectrum of the cosmic microwave background. PIXIE will measure the gravitational-wave signature of primordial inflation through its distinctive imprint in linear polarization, and characterize the thermal history of the universe through precision measurements of distortions in the blackbody spectrum. PIXIE uses an innovative optical design to achieve background-limited sensitivity in 400 spectral channels spanning over 7 octaves in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded non-imaging optics feed a polarizing Fourier Transform Spectrometer to produce a set of interference fringes, proportional to the difference spectrum between orthogonal linear polarizations from the two input beams. Multiple levels of symmetry and signal modulation combine to reduce systematic errors to negligible levels. PIXIE will map the full sky in Stokes I, Q, and U parameters with angular resolution 2.6 degrees and sensitivity 70 nK per 1degree square pixel. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r < 10(exp. -3) at 5 standard deviations. The PIXIE mission complements anticipated ground-based polarization measurements such as CMBS4, providing a cosmic-variance-limited determination of the large-scale E-mode signal to measure the optical depth, constrain models of reionization, and provide a firm detection of the neutrino mass (the last unknown parameter in the Standard Model of particle physics). In addition, PIXIE will measure the absolute frequency spectrum to characterize deviations from a blackbody with sensitivity 3 orders of magnitude beyond the seminal COBE/FIRAS limits. The sky cannot be black at this level; the expected results will constrain physical processes ranging from inflation to the nature of the first stars and the physical conditions within the interstellar medium of the Galaxy. We describe the PIXIE instrument and mission architecture required to measure the CMB to the limits imposed by astrophysical foregrounds.

Kogut, Alan↗

A Program to Detect and Characterize Extra-Solar Giant Planets

We initiated a significant hardware upgrade to the AFOE, to increase its efficiency for precise radial velocity studies to the level where we can continue to contribute usefully to extrasolar planet research on relatively bright stars. The AFOE, at a 1.5-m telescope, will of course not have the sensitivity of radial velocity instruments at larger telescopes, such as the HIRES on Keck or the Hectochelle on the MMT telescope (about to come on line). However, it has been possible to increase its efficiency for precise radial velocity studies by a factor of 4 to 5, which-combined with the large amount of telescope time available at the 1.5-m telescope-will permit us to do intensive follow-up observations of stars brighter than about 8 magnitude. The AFOE was originally designed primarily for asteroseismology using a ThAr reference. This provided useful wavelength stability over tens of minutes as required for asteroseismology, but we were unable to get a long-term (month-to-month) velocity precision better than about 15 m/s with that setup. Hence, we implemented an iodine cell as a wavelength reference for extrasolar planet studies. However, the optical design of the original AFOE did not completely span the wavelength range covered by the iodine absorption spectrum, and furthermore the optics suffered significant light loss through optical obscuration in the camera secondary. To remedy this, we replaced the AFOE grating with a new one that covered the entire iodine spectral range at somewhat lower spectral resolution, and replaced the camera with a transmitting lens. (The use of a lens was made possible by restricting the spectral range covered by the upgraded AFOE to only the iodine region.) These upgrades were successfully completed, and the instrument was tested for three nights in fall of 2002. The expected improvement in sensitivity by a factor of 4 to 5 was observed: that is, the same velocity precision as previously attained (of order 5 to 7 m/s) was now obtained on a stars that are about 4 to 5 times fainter. Unfortunately, just after installing the new AFOE optics, there was a catastrophic failure of the old Tektronix CCD. A careful investigation was made, and it was determined that the failure was probably due to too many thermal cyclings over the previous 8 years. The only solution was to purchase a new CCD. Internal funds of $16,000 were found for this purpose, and the new CCD (a thinned, back-illuminated Marconi 2K x 2K device with 13.5 micron pixels, and employing dual readout channels to keep the readout time as short as 20 seconds) was ordered, has now arrived, and is currently under test before 1 being installed in the AFOE liquid nitrogen dewar. At the same time, we expect to implement new CCD control electronics. This system should be better in many ways than the previous detector (including eliminating the need for UV flashing to maximize the quantum efficiency). We plan to install the detector on the telescope and begin operations again in April of this year.

Lindstrom, David↗

High efficiency noble gas electron impact ion source for isotope separation

An electron impact ion source has been designed for generation of noble gas ions in a compact isotope separator. The source utilizes a circular filament that surrounds an ionization chamber, enabling multiple passes of electrons through the ionization chamber. This report presents ion optical design and the results of efficiency and sensitivity measurements performed in an ion source test chamber and in the compact isotope separator. The cylindrical design produced xenon ions at an efficiency of 0.37% with a sensitivity of ~24 µA /Pa at 300 µA of electron current.

07 ISOTOPE AND RADIATION SOURCES↗

Design Studies for a Far Infrared Absolute Spectrometer for the Cosmic Background Explorer

Unrelenting symmetry of design is required to assure the thermal balance of a cryogenically cooled, rapid scan interferometer spectrometer to be mounted in vacuum with the Cosmic Background Explorer liquid helium dewar. The instrument receives inputs from Winston cone optical flux collectors, one open to space and a second coupled to a black body reference source. A differential instrument, the spectrometer produces outputs corresponding to the Fourier transform of the spectral radiance difference between the two inputs. The two outputs are sensed by four detectors, two optimized for shorter wavelength response, and two optimized for longer wavelengths. The optical design, detector and signal channel, system sensitivity, mechanics, thermal control and cryogenics, electronics and power systems, command and control, calibration, system test requirements, and the instrument interface are discussed. Recommendations for continued work are indicated for the superconducting reflective horns, the motor bearing and drive, and design detail.

Johnson, N. J. E.↗

The intermediate energy X-ray beamline at the APS

In this work, we report the optical design of the Intermediate Energy X-ray (IEX) beamline at the APS, which has been optimized to study emergent phenomena via angle-resolved photoemission spectroscopy (ARPES) and resonant soft X-ray scattering (RSXS). Driven by the scientific requirements of these two techniques the beamline consists of two separate branchlines sharing the same source, heat absorbing optics and monochromator, but each having its own refocusing optics. The ARPES branch is optimized for a very high “resolving power” and a small spot at the sample; whereas, the RSXS branch is designed for high flux and a low beam divergence at the sample. The very high “resolving power” in the ARPES branch is achieved by using a monochromator which consists of a plane mirror and a variable line spacing grating that focuses the beam at all photon energies. A flux higher than 10 10 photons/s at a “resolving power” better than 5×10 4 will be available at the sample position of the ARPES beamline on a spot size (FWHM) smaller than 21×4 μm 2 (hor.×ver.) for photon energies between 250 and 1660 eV. A second grating will increase the flux by more than a factor of 10 at a “resolving power” of 10 4 . The flux expected at the RSXS branch for energies between 250 eV and 1900 eV is higher than 4×10 12 photons/s at “resolving power” around 2.5×10 3 . The expected spot in this branch is sub-millimeter and the beam divergence is less than 0.3 mrad (FWHM).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microfield exposure tool enables advances in EUV lithography development

With demonstrated resist resolution of 20 nm half pitch, the SEMATECH Berkeley BUV microfield exposure tool continues to push crucial advances in the areas of BUY resists and masks. The ever progressing shrink in computer chip feature sizes has been fueled over the years by a continual reduction in the wavelength of light used to pattern the chips. Recently, this trend has been threatened by unavailability of lens materials suitable for wavelengths shorter than 193 nm. To circumvent this roadblock, a reflective technology utilizing a significantly shorter extreme ultraviolet (EUV) wavelength (13.5 nm) has been under development for the past decade. The dramatic wavelength shrink was required to compensate for optical design limitations intrinsic in mirror-based systems compared to refractive lens systems. With this significant reduction in wavelength comes a variety of new challenges including developing sources of adequate power, photoresists with suitable resolution, sensitivity, and line-edge roughness characteristics, as well as the fabrication of reflection masks with zero defects. While source development can proceed in the absence of available exposure tools, in order for progress to be made in the areas of resists and masks it is crucial to have access to advanced exposure tools with resolutions equal to or better than that expected from initial production tools. These advanced development tools, however, need not be full field tools. Also, implementing such tools at synchrotron facilities allows them to be developed independent of the availability of reliable stand-alone BUY sources. One such tool is the SEMATECH Berkeley microfield exposure tool (MET). The most unique attribute of the SEMA TECH Berkeley MET is its use of a custom-coherence illuminator made possible by its implementation on a synchrotron beamline. With only conventional illumination and conventional binary masks, the resolution limit of the 0.3-NA optic is approximately 25 nm, however, with EUV not expected in production before the 22-nm half pitch node even finer resolution capabilities are now required from development tools. The SEMATECH Berkeley MET's custom-coherence illuminator allows it to be used with aggressive modified illumination enabling kJ factors as low as 0.25. Noting that the lithographic resolution of an exposure tool is defined as k{sub 1}{lambda}/NA, yielding an ultimate resolution limit of 11 nm. To achieve sub-20-nm aerial-image resolution while avoiding forbidden pitches on Manhattan-geometry features with the centrally-obscured MET optic, a 45-degree oriented dipole pupil fill is used. Figure 1 shows the computed aerial-image contrast as a function of half pitch for a dipole pupil fill optimized to print down to the 19-nm half pitch level. This is achieved with relatively uniform performance at larger dimensions. Using this illumination, printing down to the 20-nm half pitch level has been demonstrated in chemically amplified resists as shown in Fig. 2. The SEMATECH Berkeley MET tool plays a crucial role in the advancement of EUV resists. The unique programmable coherence properties of this tool enable it to achieve higher resolution than other EUV projection tools. As presented here, over the past year the tool has been used to demonstrate resist resolutions of 20 half pitch. Although not discussed here, because the Berkeley MET tool is a true projection lithography tool, it also plays a crucial role in advanced EUV mask research. Examples of the work done in this area include defect printability, mask architecture, and phase shift masks.

36 MATERIALS SCIENCE↗

Telescope technology for the Far Ultraviolet Spectroscopic Explorer (FUSE)

Preliminary engineering studies are in progress to define a telescope for FUSE. General science objectives include high resolution spectroscopy in the 900-1200 A spectral region, low or moderate resolution spectroscopy in the 100-900 A range, and long slit imaging over a 1-arcmin field at a spatial resolution of 1 arcsec. Telescope design studies indicate that a 1-m-diameter Wolter-Schwarzschild type II glancing-incidence telescope with an effective collecting area of 3000 sq cm is required to meet the primary science objectives. A baseline optical design has been completed, and initial alignment sensitivities derived to begin the process of error allocation for the entire system.

Osantowski, J. F.↗

A Second Generation Multi-Angle Imaging SpectroRadiometer (MISR-2)

The Multi-angle Imaging SpectroRadiometer (MISR) has been in Earth orbit since December 1999 on NASA's Terra spacecraft. This instrument provides new ways of looking at the Earth's atmosphere, clouds, and surface for the purpose of understanding the Earth's ecology, environment, and climate. To facilitate the potential future continuation of MISR's multi-angle observations, a study was undertaken in 1999 and 2000 under the Instrument Incubator Program (IIP) of NASA Code Y's Earth Science Technology Office (ESTO) to investigate and demonstrate the feasibility of a successor to MISR that will have greatly reduced size and mass. The kernel of the program was the design, construction, and testing of a highly miniaturized camera, one of the nine that would probably be used on a future space borne MISR-like instrument. This demonstrated that the size and mass reduction of the optical system and camera electronics are possible and that filters can be assembled to meet the miniaturized packaging requirements. An innovative, reflective optics design was used, enabling the wavelength range to be extended into the shortwave infrared. This was the smallest all-reflective camera ever produced by the contractor. A study was undertaken to determine the feasibility of implementing nine (multi-angle) cameras within a single structure. This resulted in several possible configurations. It would also be possible to incorporate one of the cameras into an airborne instrument.

spectroradiometers↗

A comprehensive line spread function error for the Off-plane Grating Rocket Experiment

The Off-plane Grating Rocket Experiment (OGRE) is a soft X-ray grating spectrometer to be flown on a suborbital rocket. The payload is designed to obtain the highest-resolution soft X-ray spectrum of Capella to date with a resolution goal of R(lambda/delta lambda) > 2000 at select wavelengths in its 10 - 55 A bandpass of interest. The optical design of the spectrometer realizes a maximum resolution of R 5000 with all components performing optimally, in perfect alignment, and not considering in-flight pointing errors; however, performance errors, misalignments, and in-flight pointing errors work to degrade this performance. A comprehensive line spread function (LSF) error budget has been constructed for the spectrometer to identify errors contributing to the LSF, to determine how each affects the LSF, and to inform performance requirements and alignment tolerances for the spectrometer. In this document, the comprehensive LSF error budget for the OGRE spectrometer is presented and its implications are discussed.

Benjamin D Donovan↗

Emission spectroscopy with coded apertures for enhanced dimensionality

A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.

42 ENGINEERING↗

Ultra-sensitive high-density Rb-87 radio-frequency magnetometer

Radio-frequency (RF) atomic magnetometers (AMs) can be used in many applications, such as magnetic resonance imaging and nuclear quadrupole resonance. High-density AMs provide both superior sensitivity and large bandwidth. Previously, high-density potassium AMs were demonstrated, but these magnetometers have various disadvantages, such as high-temperature of operation and bulky design. We demonstrate a rubidium-87 RF AM with 5 fT/Hz{sup 1/2} sensitivity (3 fT Hz{sup 1/2} probe noise), which is comparable to that of the best potassium magnetometers. Our magnetometer also features a simple fiber-optic design, providing maximum flexibility for magnetic-field measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗