Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERMANENT MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Co-existence of diamagnetism and ferromagnetism and possible superconductivity in Y{sub 8}Ba{sub 5}Zn{sub 4}O{sub 21}

In the present study, we investigate structural and magnetic properties of the Y{sub 8}Ba{sub 5}Zn{sub 4}O{sub 21} structure, which was recently included in the catalog of the International Centre for Diffraction Data (ICDD) as a prototype structure. It was found that the Y{sub 8}Ba{sub 5}Zn{sub 4}O{sub 21} bulk sample seems to be electrically insulating at temperatures of liquid nitrogen and the room temperature. On the other hand, it has quite interesting magnetic properties. Diamagnetic phase transition was observed at {approx} 90 K, which resembles that of the superconducting materials. The studied composition repels permanent magnets at the liquid nitrogen temperature. Ferromagnetism also co-exists with diamagnetism in the temperature range between 50 K and 90 K. Possible reasons for these behaviors are discussed. - Research Highlights: {yields}Y{sub 8}Ba{sub 5}Zn{sub 4}O{sub 21} possesses both ferromagnetic and diamagnetic properties. {yields}A superconducting-like diamagnetic transition takes place at {approx} 90 K. {yields}Ferromagnetism and diamagnetism coexist between temperatures of 50 K and 90 K. {yields}At 10 K, only ferromagnetism exists and no traces of diamagnetism are detected. {yields}The studied samples repel permanent magnets in liquid nitrogen.

36 MATERIALS SCIENCE↗

Cluster Synthesis and Direct Ordering of Rare-Earth Transition-Metal Nanomagnets

Rare-earth transition-metal (R-TM) alloys show superior permanent magnetic properties in the bulk, but the synthesis and application of R-TM nanoparticles remains a challenge due to the requirement of high-temperature annealing above about 800 degrees C for alloy formation and subsequent crystalline ordering. Here we report a single-step method to produce highly ordered R-TM nanoparticles such as YCo(5) and Y(2)Co(17), without high-temperature thermal annealing, by employing a cluster-deposition system and investigate their structural and magnetic properties. The direct ordering is highly desirable to create and assemble R-TM nanoparticle building blocks for future permanent-magnet and other significant applications.

Balasubramanian, B↗

Controlling beam trajectory and transport in a tapered helical undulator

In this paper we present a detailed discussion of the helical undulator system developed for high extraction efficiency experiments in the tapered-enhanced stimulated superradiant amplification regime. The design is based on permanent magnet technology and comprises two Halbach arrays orthogonally oriented and shifted by 90° with respect to each other. When used in low energy beamlines for THz generation, the electron beam trajectory and transport are particularly sensitive to the undulator off-axis fields so that it becomes important to complement on-axis field measurements with analysis and tuning of the higher-order field components. Here we describe how the pulsed wire measurement technique can be effectively used to retrieve on- and off-axis magnetic field characteristics of the undulator. A simple two-dipole model is developed to guide the final adjustments to the permanent magnet positions along the array to tune the quadrupole and sextupole components of the field.

free-electron lasers↗

Preparation of highly pure α-MnBi phase via melt-spinning

High concentration of the magnetically hard α phase in the Mn-Bi alloys is important for the development of these alloys as rare-earth-free permanent magnets. Among several explored manufacturing methods, melt-spinning followed by annealing is known to be suitable of producing the most pure α structure. In this work, a series of melt-spun Mn 100-x Bi x alloys was prepared with x = 43 – 51 at a wheel speed of 67 m/s by ejecting the alloys through orifices 0.17 mm and 0.27 mm in diameter. The smaller orifice diameter favored formation of an amorphous phase in the as-spun alloys as well as a higher saturation magnetization M s in the alloys subsequently annealed at 300 °C. Although the most pure, 98 vol.%, α phase was obtained for the off-stoichiometric Mn 55 Bi 45 composition, the M s of this material was lowered, possibly because the excess Mn atoms induced antiferromagnetic coupling in the α phase. The highest M s of 78 emu/g was obtained for a composition closer to the Mn 50 Bi 50 stoichiometry, despite the slightly lower purity of α phase. Furthermore, evolution of the room-temperature coercivity with the formation of the α phase in the melt-spun alloys was studied for the Mn 55 Bi 45 ribbons compacted at 275 °C; the coercivity values of around 1 kOe obtained through this simple procedure are not sufficient for permanent magnet applications.

36 MATERIALS SCIENCE↗

Further Progress on a Design for a Super-B Interaction Region

We present an improved design for a SuperB interaction region. The new design minimizes local bending of the two colliding beams by separating all beam magnetic elements near the Interaction Point (IP). The total crossing angle at the IP is increased from 48 mrad to 60 mrad. The first magnetic element is a six slice Permanent Magnet (PM) quadrupole with an elliptical aperture allowing us to increase the vertical space for the beam. This magnet starts 36 cm from the Interaction Point (IP). This magnet is only seen by the Low-Energy Beam (LEB), the High-Energy Beam (HEB) has a drift space at this location. This allows the preliminary focusing of the LEB which has a smaller beta y* at the IP than the HEB. The rest of the final focusing for both beams is achieved by two super-conducting side-by-side quadrupoles (QD0 and QF1). These sets of magnets are enclosed in a warm bore cryostat located behind the PM quadrupole for the LEB. We describe this design for the interaction region.

43 PARTICLE ACCELERATORS↗

ERL with non-scaling fixed field alternating gradient lattice for eRHIC

The proposed eRHIC electron-hadron collider uses a "non-scaling FFAG" (NS-FFAG) lattice to recirculate 16 turns of different energy through just two beam lines located in the RHIC tunnel. This paper presents lattices for these two FFAGs that are optimized for low magnet field and to minimize total synchrotron radiation across the energy range. The higher number of recirculations in the FFAG allows a shorter linac (1.322GeV) to be used, drastically reducing cost, while still achieving a 21.2 GeV maximum energy to collide with one of the existing RHIC hadron rings at up to 250GeV. eRHIC uses many cost-saving measures in addition to the FFAG: the linac operates in energy recovery mode, so the beams also decelerate via the same FFAG loops and energy is recovered from the interacted beam. All magnets will be constructed from NdFeB permanent magnet material, meaning chillers and large magnet power supplies are not needed. This paper also describes a small prototype ERL-FFAG accelerator that will test all of these technologies in combination to reduce technical risk for eRHIC.

43 PARTICLE ACCELERATORS↗

A conceptual design of an electron spectrometer for ELI-NP

We present the geometry and field parameters of an Electron Spectrometer (ES) with two dipole magnets, considered for electron energy measurements at the High Fields QED experimental area at ELI-NP. The first magnet is a 2 meter long permanent magnet, placed inside the Interaction Chamber (IC). The second magnet is a 1.5 meters long electromagnet, placed outside IC. The pulsed electron beam will be produced by the 10 PW pulsed Laser, ‘pump-beam’, focused into one meter long capillary low density plasma cell. A second 10 PW pulsed Laser, ‘probe-beam’, will interact with the relativistic electron bunch providing the strong electromagnetic field. The ES will measure the subtle changes in the electron energy spectrum as a result of the electron beam interaction with the probe-beam field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnifying lens for 800 MeV proton radiography

This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact ECR ion source for various ion production

There is a desire that a carbon-ion radiotherapy facility will produce various ion species for fundamental research. Although the present Kei2-type ion sources are dedicated for the carbon-ion production, a future ion source is expected that could provide: (1) carbon-ion production for medical use, (2) various ions with a charge-to-mass ratio of 1/3 for the existing Linac injector, and (3) low cost for modification. A prototype compact electron cyclotron resonance (ECR) ion source, named Kei3, based on the Kei series has been developed to correspond to the Kei2 type and to produce these various ions at the National Institute of Radiological Sciences (NIRS). The Kei3 has an outer diameter of 280 mm and a length of 1120 mm. The magnetic field is formed by the same permanent magnet as Kei2. The movable extraction electrode has been installed in order to optimize the beam extraction with various current densities. The gas-injection side of the vacuum chamber has enough space for an oven system. We measured dependence of microwave frequency, extraction voltage, and puller position. Charge state distributions of helium, carbon, nitrogen, oxygen, and neon were also measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the Insulating Magnetic Field in an Accelerating Ion Diode

The results of examination of the insulating magnetic field in an accelerating ion diode are presented. This field is produced in order to suppress the electron current and thus enhance the neutron yield of the D(d, n){sup 3}He nuclear reaction. The following two designs are discussed: a gas-filled diode with inertial electrostatic confinement of ions and a vacuum diode with a laser-plasma ion source and pulsed magnetic insulation. Although the insulating field of permanent magnets is highly nonuniform, it made it possible to extend the range of accelerating voltages to U = 200 kV and raise the neutron yield to Q = 10{sup 7} in the first design. The nonuniform field structure is less prominent in the device with pulsed magnetic insulation, which demonstrated efficient deuteron acceleration with currents up to 1 kA at U = 400 kV. The predicted neutron yield is as high as 109 neutrons/pulse.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A high resolution, broad energy acceptance spectrometer for laser wakefield acceleration experiments

Laser wakefield experiments present a unique challenge in measuring the resulting electron energy properties due to the large energy range of interest, typically several 100 MeV, and the large electron beam divergence and pointing jitter >1 mrad. In many experiments the energy resolution and accuracy are limited by the convolved transverse spot size and pointing jitter of the beam. In this paper we present an electron energy spectrometer consisting of two magnets designed specifically for laser wakefield experiments. In the primary magnet the field is produced by permanent magnets. A second optional electromagnet can be used to obtain better resolution for electron energies above 75 MeV. The spectrometer has an acceptance of 2.5-400 MeV (E{sub max}/E{sub min}>100) with a resolution of better than 1% rms for electron energies above 25 MeV. This high resolution is achieved by refocusing electrons in the energy plane and without any postprocessing image deconvolution. Finally, the spectrometer employs two complimentary detection mechanisms: (1) absolutely calibrated scintillation screens imaged by cameras outside the vacuum chamber and (2) an array of scintillating fibers coupled to a low-noise charge-coupled device.

43 PARTICLE ACCELERATORS↗

Magnetic nanostructuring and overcoming Brown's paradox to realize extraordinary high-temperature energy products

Nanoscience has been one of the outstanding driving forces in technology recently, arguably more so in magnetism than in any other branch of science and technology. Due to nanoscale bit size, a single computer hard disk is now able to store the text of 3,000,000 average-size books, and today’s high-performance permanent magnets—found in hybrid cars, wind turbines, and disk drives—are nanostructured to a large degree. The nanostructures ideally are designed from Co- and Fe-rich building blocks without critical rare-earth elements, and often are required to exhibit high coercivity and magnetization at elevated temperatures of typically up to 180 6C for many important permanent-magnet applications. Here we achieve this goal in exchange-coupled hard-soft composite films by effective nanostructuring of high-anisotropy HfCo7 nanoparticles with a high-magnetization Fe65Co35 phase. An analysis based on a model structure shows that the soft-phase addition improves the performance of the hard-magnetic material by mitigating Brown’s paradox in magnetism, a substantial reduction of coercivity from the anisotropy field. The nanostructures exhibit a high room-temperature energy product of about 20.3 MGOe (161.5 kJ/m3 ), which is a record for a rare earth- or Pt-free magnetic material and retain values as high as 17.1 MGOe (136.1 kJ/m3 ) at 1806C.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of a pepper pot emittance probe and its application for ECR ion beam studies.

A pepper pot-scintillator screen system has been developed and used to measure the emittance of DC ion beams extracted from a high-intensity permanent magnet ECR ion source. The system includes a fast beam shutter with a minimum dwell time of 18 ms to reduce the degradation of the CsI(Tl) scintillator by DC ion beam irradiation and a CCD camera with a variable shutter speed in the range of 1 {micro}s-65 s. On-line emittance measurements are performed by an application code developed on a LabVIEW platform. The sensitivity of the device is sufficient to measure the emittance of DC ion beams with current densities down to about 100 nA/cm{sup 2}. The emittance of all ion species extracted from the ECR ion source and post-accelerated to an energy of 75-90 keV/charge have been measured downstream of the LEBT. As the mass-to-charge ratio of ion species increases, the normalized RMS emittances in both transverse phase planes decrease from 0.5-1.0 {pi} mm mrad for light ions to 0.05-0.09 {pi} mm mrad for highly charged {sup 209}Bi ions. The dependence of the emittance on ion's mass-to-charge ratio follows very well the dependence expected from beam rotation induced by decreasing ECR axial magnetic field. The measured emittance values cannot be explained by only ion beam rotation for all ion species and the contribution to emittance of ion temperature in plasma, non-linear electric fields and non-linear space charge is comparable or even higher than the contribution of ion beam rotation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Progress on a Superconducting Planar Undulator in the UK

Superconducting (SC) undulators can potentially reach a higher field, for short period devices, than permanent magnet devices. The latest design work on a proposed superconducting planar undulator being designed in the UK by the STFC is presented. The initial layout of the undulator, including superconducting fill factor and the cryogenic system is presented. Calculations of the wakefield heating effects due to different vacuum vessels and electron beam configurations are also presented. Another important issue for superconducting planar undulators is the effect of engineering tolerances of the pole pieces: the computer simulated effects, for different size pole errors, on the electron beam trajectory and phase error through the device are also shown.

43 PARTICLE ACCELERATORS↗

A Novel $In-Situ$ Radiation Damage Diagnostic System for Undulators

Radiation damage has been a known problem at many synchrotron radiations and free-electron lasers facilities, especially those that use hybrid or pure permanent magnet undulators to produce high brightness light. Field strength loss due to demagnetization makes it necessary to remove the insertion device from the tunnel for inspection and repair, which brings several inconveniences. We aimed to develop an in situ radiation damage detection system for undulators capable of diagnosing relative field changes of 10 -4 (100 ppm) or smaller. The system measures the flux change in a flexible printed circuit board coil attached to the undulator magnet array by periodically measuring the integral flux change during the opening and closing of the undulator gap. If the magnet block damage occurs, the signal from the coil will decrease proportionally to the damage. First tests performed on variable gap hybrid undulators for the Linac Coherent Light Source II (LCLS-II) at SLAC National Accelerator Laboratory showed that the system is capable of measuring flux changes with a relative precision of approximately 0.7 × 10 -4 over several days. Relative field changes smaller than 10 -4 were detected in short-term measurements. Here, the novel system that we propose here opens the possibility of detecting radiation damage in undulators during operation.

47 OTHER INSTRUMENTATION↗

Optimizing the Configuration of the Magnetic Deflection System of an Electron Spectrometer

The results of examination of the magnetic field produced in an electron spectrometer with permanent magnets are presented. The potential to optimize the configuration of the deflection system of this spectrometer using low-coercivity screens is demonstrated. These screens balance out the edge effects at the analyzer input and make the field in the gap more uniform.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Novel In-situ Radiation Damage Diagnostic System for Undulators

Radiation damage has been a known problem at many synchrotron radiation and free-electron lasers facilities, especially those that use hybrid or pure permanent magnet undulators to produce high brightness light. Field strength loss due to demagnetization makes it necessary to remove the insertion device from the tunnel for inspection and repair, which brings several inconveniences. Here, we aimed to develop an in-situ radiation damage detection system for undulators capable of diagnosing relative field changes of 10 -4 (100 ppm) or smaller.

47 OTHER INSTRUMENTATION↗