SEARCH · Search NASA
Results for “PV module”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
In-situ I-V measurement of a module in a PV array
In one respect, disclosed is an in-situ current-voltage (I-V) measurement device for photovoltaic modules in a photovoltaic array, comprising a variable load, wherein the variable load is configured to be connected in parallel with a module, wherein the module is connected in series with at least one other module in a string, such that the module supplies current simultaneously to the string and to the variable load, and wherein the variable load is controlled by a controller, and wherein the controller is configured to shift an I-V operating point of the module, based at least upon varying the variable load.
Space Station Freedom solar array panels plasma interaction test facility
The Space Station Freedom Power System will make extensive use of photovoltaic (PV) power generation. The phase 1 power system consists of two PV power modules each capable of delivering 37.5 KW of conditioned power to the user. Each PV module consists of two solar arrays. Each solar array is made up of two solar blankets. Each solar blanket contains 82 PV panels. The PV power modules provide a 160 V nominal operating voltage. Previous research has shown that there are electrical interactions between a plasma environment and a photovoltaic power source. The interactions take two forms: parasitic current loss (occurs when the currect produced by the PV panel leaves at a high potential point and travels through the plasma to a lower potential point, effectively shorting that portion of the PV panel); and arcing (occurs when the PV panel electrically discharges into the plasma). The PV solar array panel plasma interaction test was conceived to evaluate the effects of these interactions on the Space Station Freedom type PV panels as well as to conduct further research. The test article consists of two active solar array panels in series. Each panel consists of two hundred 8 cm x 8 cm silicon solar cells. The test requirements dictated specifications in the following areas: plasma environment/plasma sheath; outgassing; thermal requirements; solar simulation; and data collection requirements.
Industry Facing PV Degradation Prediction Tool and Database to Enable a 50-Year Life Module
The Photovoltaic (PV) industry constantly aims for lower costs, higher-efficiency cells, and improved module designs. These trends lead to using new materials, designs, and manufacturing processes, resulting in a continually changing technological landscape. These changes can potentially introduce new, unknown degradation mechanisms and failure modes that are difficult to diagnose, analyze, test, and model. This introduces uncertainty into the expected lifetime of PV modules of 25 years. Furthermore, research efforts aim for up to 50 years of service life while keeping performance degradation at a minimum for decades of outdoor weathering - putting additional pressure on improving the accuracy of long-term durability and reliability assessments. Here there is a need to organize the existing degradation data into an accessible format and to provide industry relevant tools for extrapolation from laboratory to field conditions. Because the core of this type of analysis involves calculations that are complicated but ubiquitous for many degradation processes, an enhanced predictive modeling framework will facilitate the analysis to help researchers keep up with the rapid pace of technological changes. In this work, we present an online tool that can be used to search for and analyze degradation information and extrapolate PV module performance and durability to field exposure. A graphical user interface will aid in the understanding of the results. The prediction tool will be built modular and published as open source, enabling users to expand on the existing framework. We use an integration pipeline approach that allows us to leverage weather data from the National Solar Radiation Database to perform geospatial degradation analysis in the US and worldwide. Our repository will contain various degradation models and material parameters suitable for the reliability and durability assessment of materials and components deployed outdoors. We hope to become a repository that can be used for weathering and degradation analysis for various applications beyond the PV industry.
Georgetown University Photovoltaic Higher Education National Exemplar Facility (PHENEF)
Several photographs of this facility using photovoltaic (PV) cells are shown. An outline is given of the systems requirements, system design and wiring topology, a simplified block design, module electrical characteristics, PV module and PV module matching.
Decay of Electrostatic Force of Dust Particles on Photovoltaic Modules
Photovoltaic (PV) energy yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. We have reported on direct measurements-using atomic force microscopy (AFM)-of strong electric-field-induced attraction and adhesion force (Fes) of dust particles onto solar panel that are 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, corroborated by observing the increase in system voltage-induced soiling rate. Here, we report another characteristic of Fes on soiling-long lasting or slow decay after turning off the high voltage applied to solar panels. The Fes decay time varies in a wide time range of 1 to 10 hours, depending on two factors: 1) either/both the cell or/and particle were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off-either connected through the power supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting Fes for hours can significantly affect the solar panel soiling after sunset, especially combined with water condensation.
City and County Solar PV Training Program, Module 1: Goal Setting and Clarification
This module will help attendees understand nuances between different types of renewable energy goals, the importance of terminology when setting and announcing goals, the value of formally clarifying priorities, and how priorities may impact procurement options. It is the first training in a series intended to help municipal staff procure solar PV for their land and buildings.
Launch packaging options for the photovoltaic power module cargo element
The National Aeronautics and Space Administration recently embarked on the Space Station Freedom program, which will utilize the Shuttle Orbiter for transportation to orbit. This task will be accomplished with a number of flights over several years. Each flight is unique in terms of the hardware that is manifested and the method by which it is integrated to form viable cargo elements. Work Package 4 is responsible for the electric power system for Space Station Freedom, and was delegated the authority to develop a photovoltaic (PV) power module cargo element. The PV power module consists of several unique assemblies. The first of these is the combined solar array/beta gimbal assembly. The remaining assemblies form the single combined integrated equipment assembly for each PV power module. These three combined assemblies are packaged into a launch cradle to form the PV power module cargo element, which is placed in the cargo bay of the Shuttle Orbiter for transportation to orbit. Various constraints determine the packaging options for the three PV power module combined assemblies. The size and shape of the combined assemblies in relation to the Shuttle Orbiter cargo bay dimensions and other manifested hardware are ultimately a factor in determining the acceptable packaging schemes for the PV power module cargo element. Several packaging options for the PV power module cargo element are presented. These options are discussed in terms of their impact on the overall flight hardware manifest as determined by the various constraints.
Long-lasting strong electrostatic attraction and adhesion forces of dust particles on photovoltaic modules
Photovoltaic (PV) energy-yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. The electrostatic attraction and adhesion force (F es ) of dust particles by the high voltages from solar panels have been reported to be 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, which has been corroborated by observing the increase in system voltage-induced soiling rate by setting up an outdoor test. Here, we report another characteristic of F es on soiling - long-lasting or slow decay after turning off the high voltage applied to solar panels. The F es decay time varies across a wide time range of 1 to 10 h, depending on two factors: 1) whether the cell, the particle, or both were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off - either connected through the power-supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting F es for hours can affect the solar panel soiling after sunset, and it can have an even greater effect when combined with water condensation at night.
Co-located Accelerated Testing of Module Level Power Electronics and Associated PV Panels.
Abstract not provided.
Adapting PV Tracking to Module Technology and Site Conditions
Explore the source record for details and available documents.
Space Station Freedom photovoltaic power module design status
Electric power generation for Space Station Freedom will be provided by four photovoltaic (PV) power modules using silicon solar cells during Phase 1 operation. Each PV power module requires two solar arrays with 32,800 solar cells generating 18.75 kW of dc power for a total of 75 kW. A portion of this power will be stored in nickel-hydrogen batteries for use during eclipse, and the balance will be processed and converted to 20 kHz ac power for distribution to end users through the power management and distribution system. The design incorporates an optimized thermal control system, pointing and tracking provision with the application of gimbals, and the use of orbital replacement units (ORU's) to achieve modularization. Design status of the PV power module, as derived from major trade studies, is discussed at hardware levels ranging from component to system. Details of the design are presented where appropriate.
Space Station Freedom photovoltaic power module design status
Electric power generation for the Space Station Freedom will be provided by four photovoltaic (PV) power modules using silicon solar cells during phase I operation. Each PV power module requires two solar arrays with 32,800 solar cells generating 18.75 kW of dc power for a total of 75 kW. A portion of this power will be stored in nickel-hydrogen batteries for use during eclipse, and the balance will be processed and converted to 20 kHz ac power for distribution to end users through the power management and distribution system. The design incorporates an optimized thermal control system, pointing and tracking provision with the application of gimbals, and the use of orbital replacement units to achieve modularization. The design status of the PV power module, as derived from major trade studies, is discussed at hardware levels ranging from component to system. Details of the design are presented where appropriate.
Q1-2025 Solar Photovoltaic System Cost Benchmarks
The U.S. Department of Energy’s solar office and its national laboratory partners analyze cost data for U.S. solar photovoltaic systems to develop cost benchmarks to measure progress toward goals and guide research and development programs. The cost data is available in an Excel spreadsheet model that can be downloaded here.
Historical Analysis of Champion Photovoltaic Module Efficiencies
Champion photovoltaic (PV) cell and module efficiencies have been reported in Progress in PV since 1993. Following the evolution of these efficiencies enables researchers to track the progress of various technologies. National Renewable Energy Laboratory has maintained a historical chart of the champion cell efficiencies, but has not published a similar chart of champion module efficiencies. Here, we analyze champion module efficiencies and compare them to champion cell efficiencies to better understand technology trends over the last three decades, highlighting that, in some cases, module efficiencies exceed 90% of cell efficiencies. Recommendations are provided on how to change the data collection and reporting for champion efficiencies to increase the value of these records.
Initial Results from the Floating Potential Measurement Unit aboard the International Space Station
The Floating Potential Measurement Unit (FPMU) is a multi-probe package designed to measure the floating potential of the 1nternational Space Station (ISS) as well as the density and temperature of the local ionospheric plasma environment. The role oj the FPMU is to provide direct measurements of ISS spacecraft charging as continuing construction leads to dramatic changes in ISS size and configuration. FPMU data are used for refinement and validation of the ISS spacecraft charging models used to evaluate the severity and frequency of occurrence of ISS charging hazards. The FPMU data and the models are also used to evaluate the effectiveness of proposed hazard controls. The FPMU consists of four probes: a floating potential probe, two Langmuir probes. and a plasma impedance probe. These probes measure the floating potential of the ISS, plasma density, and electron temperature. Redundant measurements using different probes support data validation by inter-probe comparisons. The FPMU was installed by ISS crewmembers, during an ExtraVehicular Activity, on the starboard (Sl) truss of the ISS in early August 2006, when the ISS incorporated only one 160V US photovoltaic (PV) array module. The first data campaign began a few hours after installation and continued for over five days. Additional data campaigns were completed in 2007 after a second 160V US PV array module was added to the ISS. This paper discusses the general performance characteristics of the FPMU as integrated on ISS, the functional performance of each probe, the charging behavior of the ISS before and after the addition of a second 160V US PV array module, and initial results from model comparisons.
Photovoltaic power modules for NASA's manned space station
The capability and the safety of manned spacecraft are largely dependent upon reliable electric power systems. Two similar space power systems able to survive the low Earth orbit environment, are being considered for NASA's Manned Space Station (SS), scheduled to begin operation in the mid 1990's. The Space Station Electric Power System (EPS) is composed of Photovoltaic (PV) Power Modules, Solar Dynamic (SD) Power Modules, and the Power Management and Distribution (PMAD) System. One EPS configuration will deliver 37.5 kW of PV based, utility grade, ac power to SS users. A second 75 kWe PV based EPS option is also being considered for SS deployment. The two EPS options utilize common modules and differ only in the total number of PV Power Modules used. Each PV Power Module supplies 18.75 kWe of ac power and incorporates its own energy storage and thermal control. The general requirements and the current preliminary design configuration of the Space Station PV Power Modules are examined.
Photovoltaic power modules for NASA's manned Space Station
The capability and the safety of manned spacecraft are largely dependent upon reliable electric power systems. Two similar space power systems able to survive the low earth orbit environment, are being considered for NASA's Manned Space Station (SS), scheduled to begin operation in the mid 1990's. The Space Station Electric Power System (EPS) is composed of Photovoltaic (PV) Power Modules, Solar Dynamic (SD) Power Modules, and the Power Management and Distribution (PMAD) System. One EPS configuration will deliver 37.5 kW of PV based, utility grade, ac power to SS users. A second 75 kWe PV based EPS option is also being considered for SS deployment. The two EPS options utilize common modules and differ only in the total number of PV Power Modules used. Each PV Power Module supplies 18.75 kWe of ac power and incorporates its own energy storage and thermal control. The general requirements and the current preliminary design configuration of the Space Station PV Power Modules are examined.