Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

Historical and Future Learning for the New Era of Multi-Terawatt Photovoltaics

Solar photovoltaics (PV) is entering a new era of multi-terawatt deployment, with 2 TW already in service and more than 75 TW predicted in many scenarios by 2050. This next era has been enabled by over five decades of cumulative advances in PV module cost reduction, performance and reliability. The current scale of deployment also introduces new needs, opportunities and challenges. In this Perspective we frame a path forwards based on learning, broadly defined as a combination of expansion of knowledge and advances through research and development, experience and collaboration. We discuss historical topics where learning has driven PV deployment until now, and emerging areas that are required to sustain high levels of future deployment. We expect progress to continue in terms of module price, performance and reliability, driven by advances in PV cell and module design, the emergence of tandem devices and increased focus on extending module lifetimes. Large-scale deployment also means large-scale sustainability and responsibility. We therefore posit that additional metrics, such as the impact on global CO2 emissions, resource consumption and design for reuse and recycling, will become increasingly important to the PV industry and provide opportunities for further learning.

14 SOLAR ENERGY↗

Performance of Hybrid Renewable Energy Power System for a Residential Building

Using fossil fuels as the primary way to generate electricity causes a significant effect on the environment. In 2019, more than 64% of the electricity in the United States of America was generated using fossil-fuel resources, while renewable energy (RE) resources contributed to only 17% of the U.S. electricity generation for the same year. Additionally, due to the complex terrain distribution of many states in the U.S., a massive opportunity of utilizing RE resources in rural and remote areas can reduce the cost of electrical grid installation for such areas. In this study, a typical residential building with an average energy utilization of 30.25 kWh/day with a demand peak of 5.34 kW was considered a case study in each state to optimize a hybrid RE system and find the best alternative electrical grid system. This study presents the best configuration between solar and wind energy with different types of energy storage. It was discovered the photovoltaic (PV) solar panels—diesel generators with battery best services in all states. The daily radiation and diesel prices substantially affect the levelized cost of energy (COE) values in each state.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV module spectral response measurements - Data and Resources

"This dataset includes spectral response curves for 12 commercial silicon module types that are deployed at SNL in Albuquerque. The modules chosen for evaluation were originally purchased by SNL for the PV Lifetime project (renamed to Systems Long-Term Evaluation [SLTE]). The majority of those modules are deployed outdoors for long-term evaluation, but several modules of each type were placed in storage for future comparison purposes. One stored module of each type was sent to NREL for the spectral response measurements. NREL used the recently developed Module Quantum Efficiency (QE) test bed. What makes this system unique is that it scans the entire module automatically, taking one or more measurements on each cell. Using the mean of these measurements at each wavelength leads to improvements in spectral mismatch correction and module power measurements but having the individual measurements also makes it possible to identify outlier cells, which could be useful for investigating underperforming modules. All measurements were performed nominally at 25°C"

14 SOLAR ENERGY↗

EMOS (Energy Management Optimization System) [SWR-21-46]

EMOS software performs a real-time hierarchal optimal control for energy systems like multi-port electric vehicles charging site with distributed energy resources (DERs) and energy storage systems (ESSs). It gathers information in real-time from electric vehicles, power grid, and DERs, solves a multi-objective energy management optimization problem, and output setpoint for chargers, ESS converters, DERs converters, and grid converters. The software incorporates a novel integration of two control tasks: a) An Energy Management Optimization (EMO), which is the brain of EMOS controller that gathers information in real-time from EVs [e.g., battery size, state-of-charge (SOC), desired SOC, and charge acceptance curve], grid (e.g., electricity price, allowed feeder capacity, ramp rate limit, and reactive power), and DERs (e.g., prediction for solar generation for PV systems). It solves a control optimization problem in real-time to find optimal setpoint for ESSs power dispatch, EVs charging rate, and grid inverters. The objectives are to (1) minimize the charging cost considering grid energy, demand charges, and battery energy, (2) minimize charging time to meet fast charging criterion, (3) keep high energy level on ESSs at the end of an operating period, while satisfying constraints related to grid, EVs, and power converters. b) Real-Time Energy Management System (RT-EMS) is a rule-based algorithm that has faster response than EMO. It receives optimal setpoint from EMO and actual measurements from the system and modify the setpoint to compensate for any fast disturbance in the system, until a new optimum solution is received. Fast disturbances may include vehicle connect/disconnect, unpredicted variation in DERs profiles, variation in grid voltage, errors in PV generation prediction, and others. In addition, RT-EMS regulates voltage at point of common coupling (PCC) by managing reactive power of grid converters.

Mohamed, Ahmed↗

Space Station Power Generation in Support of the Beta Gimbal Anomaly Resolution

The International Space Station (ISS) is the largest and most complex spacecraft ever assembled and operated in orbit. The first U.S. photovoltaic (PV) module, containing two solar arrays, was launched, installed, and activated in early December 2000. After the first week of continuously rotating the U.S. solar arrays, engineering personnel in the ISS Mission Evaluation Room (MER) observed higher than expected electrical currents on the drive motor in one of the Beta Gimbal Assemblies (BGA), the mechanism used to maneuver a U.S. solar array. The magnitude of the motor currents continued to increase over time on both BGA's, creating concerns about the ability of the gimbals to continue pointing the solar arrays towards the sun, a function critical for continued assembly of the ISS. A number of engineering disciplines convened in May 2001 to address this on-orbit hardware anomaly. This paper reviews the ISS electrical power system (EPS) analyses performed to develop viable operational workarounds that would minimize BGA use while maintaining sufficient solar array power to continue assembly of the ISS. Additionally, EPS analyses performed in support of on-orbit BGA troubleshooting exercises is reviewed. EPS capability analyses were performed using SPACE, a computer code developed by NASA Glenn Research Center (GRC) for the ISS program office.

Delleur, Ann M.↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

A 150-kW 99% Efficient All-Silicon-Carbide Triple-Active-Bridge Converter for Solar-Plus-Storage Systems

Solar-plus-storage systems could effectively mitigate the uncertainties of the photovoltaic (PV) generation and improve system reliability by adding an integrated battery energy storage system. As a three-port bidirectional isolated dc–dc converter with soft-switching capability, the triple-active-bridge (TAB) converter inherently matches the requirements of the solar-plus-storage system. However, challenges still remain in the TAB converter design to further improve system efficiency. In this article, the detailed design, implementation, and demonstration for a silicon carbide (SiC) 150-kW TAB converter are presented. Starting from a brief review of the TAB converter, the modulation scheme, power characteristics, and soft-switching region are analyzed. Then, the detailed design of the H-bridge converter building block is given. Here, to improve the system efficiency, a comprehensive characterization of the SiC gate driver with various external gate resistances is performed to address tradeoffs between switching loss and voltage overshoot during transients, as well as the thermal performance of the H-bridge building block. In addition, the design and characterization of the 20-kHz three-port transformer are also given. Comprehensive experimental studies are conducted on a full-power prototype to verify the proposed design. With a measured 99.1% peak efficiency, the proposed TAB converter can fulfill the requirements for solar-plus-storage applications.

14 SOLAR ENERGY↗

Enabling Fairness in Distributed PV Curtailment for Voltage Regulation: A Comparative Analysis

The growing adoption of photovoltaic systems in power distribution networks has yielded numerous advantages, but it has also introduced challenges, particularly in managing overvoltage issues. Uncoordinated photovoltaic integration can lead to voltage rise beyond acceptable levels. Curtailing active power is an effective method for addressing overvoltage issues in power distribution systems. Nevertheless, it is essential to distribute the curtailment fairly among the resources to maintain fairness and achieve a well-balanced utilization of renewable energy. This paper presents a comparative study of different fairness schemes for active power curtailment in photovoltaic integration systems. Three different curtailment methods are selected for demonstration: i) proportional, ii) egalitarian, and iii) financial. The study involves evaluating the curtailment schemes based on their ability to distribute the curtailed power among the photovoltaic systems in a justifiable manner, focusing on their formulation and distributed solution. A detailed performance comparison is carried out to highlight the cost of catering for fairness schemes in photovoltaic curtailment using relevant metrics, where simulations are carried out using a modified IEEE 123-bus test case.

Mukherjee, Monish↗

Real-time Simulation Framework for Hardware-in-the-Loop Testing of Multi-port Autonomous Reconfigurable Solar Power Plant (MARS)

Multiport autonomous reconfigurable solar power plant (MARS) has been proposed for integrated development of photovoltaic (PV) and energy storage system (ESS) that can connect to high-voltage direct current (HVdc) and alternating current (ac) transmission grid. To de-risk the development of this complex integrated system that consists of hundreds to thousands of power electronics modules, a controller hardware-in-the-loop (cHIL) test setup will be extremely beneficial. The cHIL testing can be used for evaluation of modules as well as the hierarchical control system in MARS. With the unique configuration of power electronics modules in MARS, it becomes necessary to develop custom-designed real-time simulation models in the cHIL setup in absence of off-the-shelf models. In this paper, high-fidelity dynamic model of MARS, control algorithms at the lower level, and required communication algorithms are developed and optimized for real-time performance in the cHIL setup. Real-time experimental results from the cHIL are provided.

Dong, Zerui↗

Optimizing Repowering and Lifecycle Decisions with PV ICE and SAM

Should you repower or extend the life of your PV system? Are high-efficiency modules, durable modules, or recyclable modules the best option for your site and goals? Evaluating the trade-offs in design and lifecycle strategies can be complex. The PV in Circular Economy (PV ICE) tool is an open-source model designed to help developers, modelers, and decision-makers assess material flows, energy return on investment (EROI), and financial viability of PV systems. Now integrated with the System Advisor Model (SAM), PV ICE enables site-specific comparisons of lifecycle strategies - such as repowering benefits, module selection for reliability and recyclability, among others. This interactive tutorial will provide hands-on experience with PV ICE using Google Collab, exploring scenario-based analyses on these topics.

36 MATERIALS SCIENCE↗

Extended Accelerated Stress Testing of Lamination-Free Edge-Sealed Photovoltaic Minimodules

Lamination-free minimodules are constructed with silicon solar cells between glass sheets and an edge seal of polyisobutylene and silicone. These samples are stressed using a repeated sequential testing sequence including ultraviolet-containing simulated solar spectrum light exposure at elevated temperature, damp heat, humidity freeze, and thermal cycling adapted from the International Electrotechnical Commission (IEC) TS 63209-2:2022. The minimodule performance throughout the stressing is characterized by flash testing and electroluminescence imaging. Results are compared to conventional laminated minimodules using the same type of solar cells. The lamination-free minimodules experience up to 8% power loss compared to roughly 3% for the laminated versions. However, those losses, dominated by current and fill factor, are caused by glass soiling and busbar ribbon separation on the cells. When glass is replaced and the stressed cells are contacted with probes bypassing the delaminated ribbons, the initial performance is recovered, and overall losses of the lamination-free samples become negligible.

14 SOLAR ENERGY↗

Estimating the impact of tariff-driven behind-the-meter storage operation on distribution grid investments

Increasing growth of distributed solar photovoltaics (PV) and electric vehicles (EV) can strain local distribution networks and require costly upgrades. Distributed battery storage, often deployed alongside PV, can be used to mitigate those costs, depending on how batteries are operated. This study evaluates the potential deferral value of distributed battery storage across a range of tariff structures, focusing on the rate structures most commonly available to residential customers today and related variants. Deferrals are evaluated with a least-cost distribution grid expansion optimization model to identify requirements on line reconductoring, transformer upgrades, and voltage regulator installations under each tariff. Results show that TOU rates and net billing tariffs can yield meaningful deferral value, depending on specific tariff structure features. Under the best performing tariff structure tested, storage produced a median annualized deferral value of $7.18 per kW of storage capacity ( kW S ) across all feeders in the sample, though deferral values were considerably larger for feeders with peak loads that coincide with utility system peak, i.e., timing of TOU peak period. In contrast, under an unrestricted TOU design with no restrictions on grid charging or discharging, the median deferral value was $0/ kW S illustrating the critical importance of tariff structure details.

Rodriguez-Garcia, Luis↗

Synchronverter-based Control of Multi-Port Autonomous Reconfigurable Solar Plants (MARS)

Control of integrated photovoltaic (PV) plants with energy storage systems (ESSs) has become an important research and development topic in recent times. In this context, a Multi-port Autonomous Reconfigurable Solar (MARS) plant that integrates PV and ESS to alternating current transmission grid and high-voltage direct current (HVdc) link is studied in this paper. With penetration of power electronic based resources in the grid, the grid’s capability to recover from frequency or voltage disturbances are reduced. Therefore, one of the vital objectives of any new grid integrated power electronic resource is to provide advanced control functions like voltage and frequency support to the grid during disturbances. In this research work, a detailed implementation of a synchronverter-based control algorithm of MARS is presented. The proposed control algorithm and the MARS control architecture are evaluated through simulations on PSCAD/EMTDC simulation platform to showcase the performance in different operating conditions. In addition, they are evaluated in Opal-RT offline simulation models which can also be used to perform control-hardware-in-the-loop (cHIL) tests.

Marthi, Phani Ratna Vanamali↗

Network Models of Active Degradation Mechanisms and Pathways for Service Life Prediction of Indoor and Outdoor PV Modules

ct: PV service lifetime prediction (SLP) enables accurate calculation of levelized cost of energy (LCOE), which is crucial to rationalizing PV investment and installation. However, SLP is challeging since PV reliability in the field is affected by many combined factors, including various environmental stresses and module quality. In order to map out the active degradation mechanisms and pathways that best resemble real world conditions, we introduce the framework of a study protocol and use network models fitted to data, to enable analysis and SLP of complex PV systems with multiple active degradation mechanisms. The study protocol is the experimental design, including module variants and different exposure conditions, selection of evaluation methods, time-series data acquisition and training of network models to these data. We present SLP of minimodules in the lab and PV systems in the field. For lab SLP, minimodules with 8 variants based on manufacturer, architecture, and encapsulation were prepared and aged in modified damp heat with or without full spectrum light exposure. Stepwise I-V and Suns-Voc data acquisition tracks changes in electrical properties including Rs,IV, Isc,IV, Vmp,PIV providing insights into power loss of minimodules. Network structural equation modeling (netSEM) was utilized to construct degradation pathway models that identify active degradation mechanisms and predict power loss over time. For field SLP, datastreams of Pmp values and I-V curve datastreams of two types of modules installed in three distinctly different Köppen-Geiger climate zones for 9 years were acquired. With power loss modes corresponding to uniform current loss (ΔPIsc), recombination (ΔPVoc), series resistance (ΔPRs), and current mismatch (ΔPImis) determined, the performance loss rates (PLR) were determined using PVplr. We show how to establish a study protocol framework to ensure appropriate parametric variations and valid data collection from the variants of your complex systems. Then the data-driven netSEM model fitting provides a comprehensive mapping of multiple active degradation mechanisms, and accurate service life prediction.

network model, degradation, photovoltaic, solar↗

Dronebase Photovoltaic (PV) Fleet Imagery Quantitative Evaluation (CRADA CRD-22-22941 Final Report)

Combine the Dronebase aerial imagery with corresponding sites in the NLR Photovoltaic (PV) Fleets database. By combining these two data sources in an aggregated, anonymized fashion, we can perform the following analyses: quantifying power loss due to outages caused by stuck trackers, string outages, and shading/snow, validate site metadata, including tilt and azimuth, and correlate.

14 SOLAR ENERGY↗

Valuable Data Provided by PASP Plus Flight Experiment After 1 Year in Orbit

Successfully launched on August 3, 1994, the Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) flight experiment is a joint Air Force Phillips Laboratory/NASA Lewis Research Center program designed to test a variety of new and existing photovoltaic (PV) cell and array technologies within the space environment. The experiment consists of 12 different experimental photovoltaic modules, along with numerous diagnostic instruments that measure the space environment and interactions between the experimental modules and that environment. Power Technology Division personnel at Lewis, who had the primary responsibility for integrating the individual photovoltaic module experiments, continue to analyze and interpret the current-voltage characteristics and environmental effects data received back from the spacecraft. The major goals of the experiment included determining the long-term performance of the photovoltaic modules within a high-radiation environment (PASP Plus was launched into an elliptical, high-radiation orbit) and measuring the interactions between the experimental modules and the space plasma when the modules were biased at high positive and negative voltages. Understanding array interactions within the space plasma is critical to spacecraft power system operations and important to providing higher bus voltage designs in the future.

Source record↗

Role of the social factors in success of solar photovoltaic reuse and recycle programmes

By 2050, the cumulative mass of end-of-life photovoltaic (PV) modules may reach 80 Mt globally. The impacts could be mitigated by module recycling, repair and reuse; however, previous studies of PV circularity omit the consideration of critical social factors. Here we used an agent-based model to integrate social aspects with techno-economic factors, which provides a more realistic assessment of the circularity potential for previously studied interventions that assesses additional interventions that cannot be analysed using techno-economic analysis alone. We also performed a global sensitivity analysis using a machine-learning metamodel. We show that to exclude social factors underestimates the effect of lower recycling prices on PV material circularity, which highlights the relevance of considering social factors in future studies. Interventions aimed at changing customer attitudes about used PV boost the reuse of modules, although used modules can only satisfy one-third of the US demand during 2020–2050, which suggests that reuse should be complemented by recycling.