Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position Sensitive Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Prototype reactor-antineutrino detector based on 6 Li-doped pulse-shape-discriminating plastic scintillator

An aboveground 60-kg reactor-antineutrino detector prototype, comprising a two-dimensional array of 36 6 ⁢Li-doped pulse-shape-sensitive plastic scintillator bars, is described. Each bar is 50 cm long with a square cross section of 5.5 cm. Doped with 6 ⁢Li at 0.1% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-𝛽-decay (IDB) reaction. Each bar is wrapped with a specular reflector that directs photons toward photomultiplier tubes mounted at both ends of the bar. Here, this paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as pulse-shape discrimination, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.

Physics↗

Testing and Performance Validation of a Shielded Waste Segregation and Clearance Monitor Designed for the Measurement of Low Level Waste-13043

This paper describes the development, testing and validation of a shielded waste segregation and clearance monitor designed for the measurement of low-density low-level waste (LLW). The monitor is made of a measurement chamber surrounded by detectors and a shielded outer frame. The shielded chamber consists of a steel frame, which contains typically 1.5 inches (3.81 cm) of lead and 0.5 inches (1.27 cm) of steel shielding. Inside the shielding are plastic scintillator panels, which serve as gross gamma ray detectors. The detector panels, with embedded photomultipliers, completely surround the internal measurement chamber on all 6 sides. Care has been taken to distribute the plastic scintillator detectors in order to optimise both the efficiency for gamma ray detection and at the same time achieve a volumetric sensitivity, which is as uniform as possible. A common high voltage power supply provides the bias voltage for each of the six photomultipliers. The voltage signals arising from the detectors and photomultipliers are amplified by six sensitive amplifiers. Each amplifier incorporates a single channel analyser with both upper and lower thresholds and the digitised counts from each detector are recorded on six scalars. Operation of the device is by means of a microprocessor from which the scalars are controlled. An internal load cell linked to the microprocessor determines the weight of the waste object, and this information is used to calculate the specific activity of the waste. The monitor makes background measurements when the shielded door is closed and a sample, usually a bag of low-density waste, is not present in the measurement chamber. Measurements of the minimum detectable activity (MDA) of an earlier large volume prototype instrument are reported as part of the development of the Waste Segregation and Clearance Monitor (WSCM) described in the paper. For the optimised WSCM a detection efficiency of greater than 32% was measured using a small Cs-137 source placed in the centre of the measurement chamber. Small sources have also been used to determine the spatial variation of the detection efficiency for various positions within the measurement chamber. The data have been used to establish sentencing limits and different 'fingerprints' for specific waste streams including waste streams containing fission products and others based on other radionuclides including Am-241. Some of the test data that are presented have been used to validate the instrument performance. The monitor is currently in routine use at a nuclear facility for the measurement and sentencing of low-density low activity radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Infrared (IR) photon-sensitive spectromicroscopy in a cryogenic environment

A system designed to suppress thermal radiation background and to allow IR single-photon sensitive spectromicroscopy of small samples by using both absorption, reflection, and emission/luminescence measurements. The system in one embodiment includes: a light source; a plurality of cold mirrors configured to direct light along a beam path; a cold or warm sample holder in the beam path; windows of sample holder (or whole sample holder) are transparent in a spectral region of interest, so they do not emit thermal radiation in the same spectral region of interest; a cold monochromator or other cold spectral device configured to direct a selected fraction of light onto a cold detector; a system of cold apertures and shields positioned along the beam path to prevent unwanted thermal radiation from arriving at the cold monochromator and/or the detector; a plurality of optical, IR and microwave filters positioned along the beam path and configured to adjust a spectral composition of light incident upon the sample under investigation and/or on the detector; a refrigerator configured to maintain the detector at a temperature below 1.0K; and an enclosure configured to: thermally insulate the light source, the plurality of mirrors, the sample holder, the cold monochromator and the refrigerator.

47 OTHER INSTRUMENTATION↗

Inferring Selected Cloud Properties from Satellite Lightning Data

The recent advent of satellite lightning detection programs has introduced a new potential for obtaining global information about other (hard to measure) cloud properties. We have made use of observations together with numerical model studies to show that positive correlations exist between: (1) lightning flashrate (F) and vertical velocity (w); and (2) flashrate (F) and the amount of condensate (water and ice) lofted through the -10 C isotherm (C(sub u)). The lightning flashrate appears to be very sensitive to the magnitude of the updraft velocity, with F increasing rapidly with w above a threshold of w approx. = 5-10 m/s. By contrast, we have found that the flashrate/condensate relationship appears to be approximately linear. We are currently refining the F-updraft and F-condensate relationships with further model studies before applying them to lightning data from the Optical Transient Detector (OTD) and the Lightning Imaging Sensor (LIS). We hope, with this method, to provide estimates of the large scale vertical water transport by continental convective systems over seasonal timescales.

Schroeder, Vicki↗

Probing individual single atom electrocatalyst sites by advanced analytical scanning transmission electron microscopy

Single atom electrocatalysts (SAEs) are promising next-generation materials for promoting a variety of important reactions, such as the oxygen reduction, nitrogen reduction, and CO 2 reduction reactions. While bulk characterization techniques such as X-ray absorption spectroscopy and Mössbauer spectroscopy have significantly enhanced our understanding of these catalysts, direct probing of individual single metal atom sites at the atomic scale is necessary to understand local variations in the properties of these sites and accelerate design and synthesis of improved SAEs. Aberration-corrected scanning transmission electron microscopy (STEM) has become a powerful tool for providing this type of atomic-scale information about SAE metal sites. These sites are typically unstable under the electron beam, however, which, in combination with conventional acquisition methods and detectors, has limited the type and quantity of information obtainable by spectroscopic STEM techniques. Here, we map multiple individual SAE metal sites in a nitrogen-doped carbon containing atomically dispersed Fe and Re (FeReNC) at the atomic scale by direct electron detection electron energy-loss spectroscopy (EELS). Direct electron detection provides an improved signal-to-noise ratio over conventional scintillator-based detectors and enables detection and real space localization of weak signals. In addition, we demonstrate an automated method for identification of metal atom positions, placement of the probe on these sites, and simultaneous EELS and energy dispersive X-ray spectroscopic (EDS) signal acquisition. This simultaneous acquisition of EELS and EDS provides access to the composition and bonding of a wide range of SAE metal sites. In this study, focusing the probe directly on the metal sites also increases the relevant data acquisition rate by more than an order of magnitude over two-dimensional mapping, enabling improved statistical measurements of site properties. The versatility, sensitivity, and speed that these techniques provide enhances our ability to probe the local elemental and chemical environment of a large number of individual SAE metal site structures at the atomic scale, enabling an improved understanding of the variations in the local properties of these electrocatalysts to be gained. As a result, significantly increased information about individual metal sites will be available to future electrochemical studies through these techniques, accelerating the development of advanced SAEs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

Taking three-dimensional x-ray diffraction (3DXRD) from the synchrotron to the laboratory scale

Three-dimensional x-ray diffraction (3DXRD), a rotating x-ray diffraction technique, is a powerful tool for studying the micromechanical behavior of polycrystalline materials, capable of measuring the volume, position, orientation, and strain of thousands of grains simultaneously. However, its application has been historically limited to synchrotron facilities. Here, we present the first demonstration of laboratory-scale 3DXRD (Lab-3DXRD) using a liquid-metal-jet source. Lab-3DXRD achieves accuracy comparable to synchrotron-based 3DXRD, as validated against laboratory diffraction contrast tomography (LabDCT) and synchrotron-3DXRD. Over 96% of the grains detected with Lab-3DXRD are cross-validated, particularly for coarse grains (> ~60 μm), while the results suggest that finer grains should be accessible by taking advantage of high-efficiency detectors. We further demonstrate that its sensitivity to finer grains is enhanced by incorporating pre-characterization into the analysis. This study establishes Lab-3DXRD as a practical alternative to synchrotron techniques, making 3DXRD accessible to a wider range of academic and industrial researchers.

characterization and analytical techniques↗

The Athena Mars Rover Science Payload

The Mars Surveyor missions that will be launched in April of 2001 will include a highly capable rover that is a successor to the Mars Pathfinder mission's Sojourner rover. The design goals for this rover are a total traverse distance of at least 10 km and a total lifetime of at least one Earth year. The rover's job will be to explore a site in Mars' ancient terrain, searching for materials likely to preserve a record of ancient martian water, climate, and possibly biology. The rover will collect rock and soil samples, and will store them for return to Earth by a subsequent Mars Surveyor mission in 2005. The Athena Mars rover science payload is the suite of scientific instruments and sample collection tools that will be used to perform this job. The specific science objectives that NASA has identified for the '01 rover payload are to: (1) Provide color stereo imaging of martian surface environments, and remotely-sensed point discrimination of mineralogical composition. (2) Determine the elemental and mineralogical composition of martian surface materials. (3) Determine the fine-scale textural properties of these materials. (4) Collect and store samples. The Athena payload has been designed to meet these objectives. The focus of the design is on field operations: making sure the rover can locate, characterize, and collect scientifically important samples in a dusty, dirty, real-world environment. The topography, morphology, and mineralogy of the scene around the rover will be revealed by Pancam/Mini-TES, an integrated imager and IR spectrometer. Pancam views the surface around the rover in stereo and color. It uses two high-resolution cameras that are identical in most respects to the rover's navigation cameras. The detectors are low-power, low-mass active pixel sensors with on-chip 12-bit analog-to-digital conversion. Filters provide 8-12 color spectral bandpasses over the spectral region from 0.4 to 1.1 micron Narrow-angle optics provide an angular resolution of 0.28 mrad/pixel, nearly a factor of four higher than that of the Mars Pathfinder and Mars Surveyor '98 cameras. Image compression will be performed using a wavelet compression algorithm. The Mini-Thermal Emission Spectrometer (Mini-TES) is a point spectrometer operating in -the thermal IR. It produces high spectral resolution (5 /cm) image cubes with a wavelength range of 5-40 gm, a nominal signal/noise ratio of 500:1, and a maximum angular resolution of 7 mrad (7 cm at a distance of 10 in). The wavelength region over which it operates samples the diagnostic fundamental absorption features of rockforming minerals, and also provides some capability to see through dust coatings that could tend to obscure spectral features. The mineralogical information that Mini-TES provides will be used to select from a distance the rocks and soils that will be investigated in more detail and ultimately sampled. Mini-TES is derived from the MO/MGS TES instrument, but is significantly smaller and simpler. The instrument uses an 8-cm Cassegrain telescope, a Michelson interferometer, and uncooled pyroelectric detectors. Along with its mineralogical capabilities, Mini-TES can provide information on the thermophysical properties of rocks and soils. Viewing upward, it can also provide temperature profiles through the martian atmospheric boundary layer. Elemental and Mineralogical Composition: Once promising samples have been identified from a distance using Pancam/Mini-TES, they will be studied in detail using up to three compositional sensors that can be placed directly against them by an Instrument Arm. The two compositional sensors, presently on the payload are an Alpha-Proton-X-Ray Spectrometer (APXS), and a Mossbauer Spectrometer. The APXS is derived closely from the instrument that flew on Mars Pathfinder. Radioactive alpha sources and three detection modes (alpha, proton, and x-ray) provide elemental abundances of rocks and soils to complement and constrain mineralogical data. The Athena APXS will have a revised mechanical design that will cut down significantly on backscattering of alpha particles from martian atmospheric carbon. It will also include a target of known elemental composition that will be used for calibration purposes. The Athena Mossbauer Spectrometer is a diagnostic instrument for the mineralogy and oxidation state of Fe-bearing phases, which are particularly important on Mars. The instrument measures the resonant absorption of gamma rays produced by a Co-57 source to determine splitting of nuclear energy levels in Fe atoms that is related to the electronic environment surrounding them. It has been under development for space flight for many years at the Technical University of Darmstadt. The Mossbauer Spectrometer (and the other arm instruments) will be able to view a small permanent magnet array that will attract magnetic particles in the martian soil. The payload may also include a Raman Spectrometer. If included, the Raman Spectrometer will provide precise identification of major and minor mineral phases. It requires no sample preparation, and is also sensitive to organics. Fine-Scale Texture: The Instrument Arm a also carries a Microscopic Imager that will obtain high-resolution monochromatic images of the same materials for which compositional data will be obtained. Its spatial resolution is 20 micron/pixel over a 1 cm depth of field, and 40 micron/pixel over a 1-cm depth of field. Like Pancam, it uses the same active pixel sensor detectors and electronics as the rover's navigation cameras. The Instrument Arm is a three degree-of-freedom arm that uses designs and components from the Mars Pathfinder and Mars Surveyor '98 projects. Its primary function is instrument positioning. Along with the instruments noted above, it also carries a brush that can be used to remove dust and other loose coatings from rocks. Sample Collection and Storage: Martian rock and soil samples will be collected using a low-power rotary coring drill called the Mini-Corer. An important characteristic of this device is that it can obtain intact samples of rock from up to 5 cm within strong boulders and bedrock, Nominal core dimensions are 8xl7 mm. The Mini-Corer drills a core to the commanded depth in a rock, shears it off, retains it, and extracts it. It can also acquire samples of loose soil, using soil sample cups that are pressed downward into loose material. The Mini-Corer can drill at angles from vertical to 45' off vertical. It has six interchangeable bits for long life. Mechanical damage to the sample during drilling is minimal, and heating is negligible. After acquisition, the sample may be viewed by the arm instruments, and/or placed in one of 104 compartments in the Sample Container. A subset of the acquired samples may be replaced with other samples obtained later if desired. The Sample Container has no moving parts, and is mounted external to the rover for easy removal by the Mars Surveyor 2005 flight system. Operation of the rover will make extensive use of automated onboard navigation and hazard avoidance capabilities. Otherwise, use of onboard autonomy is minimal. Data downlink capability is about 40 Mbit/sol, and the use of the Mars Surveyor '01 orbiter for data relay imposes a limit of at most two command cycles per sol. Because of the significant amount of time available between command cycles, all payload elements will be operated sequentially, rather than in parallel.; this approach also significantly simplifies operations and minimizes peak power usage. The landing site for the '01 rover has not been selected yet. Site selection will make as full use as possible of Mars Global Surveyor data, and will involve substantial input from the broad Mars science community. Summary: The following table describes the mass, power, providers, and key scientific objectives of all the major elements of the Athena payload. Additional Athena payload information may be found at: http://astrosun.tn.cornell.edu/athena/index.html. Additional information contained in the original.

Squyes, S. W.↗

Wide-Range Temperature Sensors with High-Level Pulse Train Output

Two types of temperature sensors have been developed for wide-range temperature applications. The two sensors measure temperature in the range of -190 to +200 C and utilize a thin-film platinum RTD (resistance temperature detector) as the temperature-sensing element. Other parts used in the fabrication of these sensors include NPO (negative-positive- zero) type ceramic capacitors for timing, thermally-stable film or wirewound resistors, and high-temperature circuit boards and solder. The first type of temperature sensor is a relaxation oscillator circuit using an SOI (silicon-on-insulator) operational amplifier as a comparator. The output is a pulse train with a period that is roughly proportional to the temperature being measured. The voltage level of the pulse train is high-level, for example 10 V. The high-level output makes the sensor less sensitive to noise or electromagnetic interference. The output can be read by a frequency or period meter and then converted into a temperature reading. The second type of temperature sensor is made up of various types of multivibrator circuits using an SOI type 555 timer and the passive components mentioned above. Three configurations have been developed that were based on the technique of charging and discharging a capacitor through a resistive element to create a train of pulses governed by the capacitor-resistor time constant. Both types of sensors, which operated successfully over the wide temperature range, have potential use in extreme temperature environments including jet engines and space exploration missions.

Hammoud, Ahmad↗

A space qualified thermal imaging system using a Pt Si detector array

EDO Corporation, Barnes Engineering Division designed and constructed a high resolution thermal imaging system on contract to Lockheed for use in the SDI Star Lab. This employs a Pt Si CCD array which is sensitive in the spectral range of 3 to 5 microns. Star Lab will be flown in the Shuttle bay and consists basically of a large, reflecting, tracking telescope with associated sensors and electronics. The thermal imaging system is designed to operate in the focal plane of this telescope. The configuration of the system is illustrated. The telescope provides a collimated beam output which is focussed onto the detector array by a silicon objective lens. The detector array subtends a field of view of 1.6 degrees x 1.22 degrees. A beam switching mirror permits bypassing the large telescope to give a field of 4 degrees x 3 degrees. Two 8 position filter wheels are provided, and background radiation is minimized by Narcissus mirrors. The detector is cooled with a Joule-Thompson cryostat fed from a high pressure supply tank. This was selected instead of a more convenient closed-cycle system because of concern with vibration. The latter may couple into the extremely critical Starlab tracking telescope. The electronics produce a digitized video signal for recording. Offset and responsivity correction factors are stored for all pixels and these corrections are made to the digitized output in real time.

Astheimer, Robert W.↗

Perspectives for Measuring Neutrino Cross-Sections at Short Baseline Detectors (ICARUS and DUNE-PRISM-like Detector) and Their Implications for Precision Physics

Neutrino physics is rapidly advancing with current and future experiments promising high-statistics data, enabling unprecedented accuracy in measuring Standard Model (SM) parameters and providing crucial insights into neutrino-nucleus interactions. The ICARUS experiment, utilizing LAr TPC technology, is pivotal in this growth. As the far detector of the SBN program at Fermilab, ICARUS is set to investigate the neutrino anomalies observed in LSND and MiniBooNE and prepare for future long-baseline experiments like DUNE. Positioned along the BNB and 5.75°off-axis from the NuMI beamline, ICARUS benefits from numerous neutrino interactions, allowing for precise neutrino-argon nucleus cross-section measurements, which will benchmark future DUNE measurements. This work presents the prospects and progress in measuring the cross-section of the NuMI νµ CC inclusive channel in the ICARUS experiment. High-statistics data will also enable precise determinations of fundamental parameters like the weak mixing angle and the neutrino charge radius (NCR), crucial for testing the SM and exploring potential new physics. This work includes studies of future near detectors, such as DUNE-PRISM, which are sensitive to radiative corrections in neutrino-electron scattering. The DUNE-PRISM configuration allows for the analysis of different neutrino energy spectra, promising accurate NCR measurements with controlled systematic uncertainties.

Moreno-Granados, Guadalupe↗

SURVEY SIMULATIONS OF A NEW NEAR-EARTH ASTEROID DETECTION SYSTEM

We have carried out simulations to predict the performance of a new space-based telescopic survey operating at thermal infrared wavelengths that seeks to discover and characterize a large fraction of the potentially hazardous near-Earth asteroid (NEA) population. Two potential architectures for the survey were considered: one located at the Earth–Sun L1 Lagrange point, and one in a Venus-trailing orbit. A sample cadence was formulated and tested, allowing for the self-follow-up necessary for objects discovered in the daytime sky on Earth. Synthetic populations of NEAs with sizes as small as 140 m in effective spherical diameter were simulated using recent determinations of their physical and orbital properties. Estimates of the instrumental sensitivity, integration times, and slew speeds were included for both architectures assuming the properties of newly developed large-format 10 μm HgCdTe detector arrays capable of operating at ∼35 K. Our simulation included the creation of a preliminary version of a moving object processing pipeline suitable for operating on the trial cadence. We tested this pipeline on a simulated sky populated with astrophysical sources such as stars and galaxies extrapolated from Spitzer Space Telescope and Wide-field Infrared Explorer data, the catalog of known minor planets (including Main Belt asteroids, comets, Jovian Trojans, planets, etc.), and the synthetic NEA model. Trial orbits were computed for simulated position-time pairs extracted from the synthetic surveys to verify that the tested cadence would result in orbits suitable for recovering objects at a later time. Our results indicate that the Earth–Sun L1 and Venus-trailing surveys achieve similar levels of integral completeness for potentially hazardous asteroids larger than 140 m; placing the telescope in an interior orbit does not yield an improvement in discovery rates. This work serves as a necessary first step for the detailed planning of a next-generation NEA survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Diffuse Reflection of Laser Light From Clouds

Laser light reflected from an aqueous suspension of particles or "cloud" with known thickness and particle size distribution defines the "cloud radiative Green's function", G. G is sensitive to cloud thickness, allowing retrieval of that important quantity. We describe a laboratory simulation of G, useful in design of an offbeam Lidar instrument for remote sensing of cloud thickness. Clouds of polystyrene microspheres suspended in water are analogous to real clouds of water droplets suspended in air. The size distribution extends from 0.5 microns to 25 microns, roughly lognormal, similar to real clouds. Density of suspended spheres is adjusted so photon mean-free-path is about 10 cm, 1000 times smaller than in real clouds. The light source is a Nd:YAG laser at 530 nm. Detectors are flux and photon-counting PMTs, with a glass probe for precise positioning. A Labview 5 VI controls position and data acquisition, via an NI Motion Control board connected to a stepper motor driving an Edmund linear slider,and a 16-channel 16-bit NI-DAQ board. The stepper motor is accurate to 10 microns. Step size is selectable. Far from the beam, the rate of exponential increase in the beam direction scales as expected from diffusion theory, linearly with cloud thickness, and inversely as the square root of the reduced optical thickness, independent of particle size. Nearer the beam the signal increases faster than exponential and depends on particle size. Results verify 3D Monte Carlo simulations that demonstrate detectability of remotely sensed offbeam returns, without filters at night, with narrow bandpass filter in day.

Cahalan, R. F.↗

Performance of the CMS RPC upgrade using 2D fast timing readout system

Here, we present a new generation of Resistive Plate Chambers (RPC) that are able to withstand high particle fluxes (up to 2 kHz cm -2 ). These chambers will be instrumented with a precise timing readout electronics and they are proposed to equip two of the four high eta stations of the CMS muon system.Two-gap RPC detectors, with each gap made of two 1.4 mm High Pressure Laminate (HPL) electrodes and separated by a gas gap of the same thickness, are proposed. The new scheme reduces the amount of the avalanche charge produced by the passage of a charged particle through the detector. This improves the RPC rate capability by reducing the needed time to absorb this charge. To keep the RPC efficiency high a sensitive, low-noise and high time resolution Front-End Electronics Board (FEB) is needed to cope with the low charge signal. An ASIC called PETIROC that has all these characteristics is proposed to read out the new chambers. A thin (0.6 mm) Printed Circuit Board (PCB), 165 cm long, equipped with pickup strips of average pitch of 0.75 cm is inserted between the two RPC gaps. The strips are read out from both ends and the arrival time difference of the two signals is used to determine the particle position along the strip ( η position). The absolute time measurement will also be used to reduce the data ambiguity due to the expected high pileup at the High-Luminosity phase of the Large Hadron Collider (HL-LHC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A micron resolution optical scanner for characterization of silicon detectors

The emergence of high position resolution (∼10 μm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 μm at 1 − σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 μm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron beam characterization via quantum coherent electric field imaging

We demonstrate an all-optical, minimally invasive electron beam (𝑒−beam) characterization using Rydberg electrometry. An 𝑒-beam passes through a localized detector volume containing thermal Rb atoms that are optically excited in a quantum superposition of ground and Rydberg states. The 𝑒-beam's electric field perturbs atomic coherence and modifies resonance fluorescence in a narrow spectral region near the two-photon optical transition. Imaging Rb fluorescence provides a map of the electric field from the 𝑒-beam via Rydberg state Stark shifts and allows us to reconstruct the 𝑒-beam width, centroid position, and current. For an 𝑒-beam of 20 keV and electron currents of 20–40 µ⁢A, we measured the centroid position with an accuracy of ≤ 8 µ⁢m and width to within 100 µ⁢m, limited by the experimental sensitivity of electric field reconstruction of ∼0.02 V/cm. This method is suitable for a wide range of electron energies and currents, and can be adopted for nuclear and high-energy experiments for minimally invasive real-time diagnostics and profiling of charged particle beams.

Behary, Rob [College of William and Mary, Williams↗

WE-D-BRF-02: Acoustic Signal From the Bragg Peak for Range Verification in Proton Therapy

Purpose: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams. Aim of this work is to study the feasibility of determining the ion range with sub-mm accuracy by use of high frequency ultrasonic (US) transducers and to image the Bragg peak by tomography. Methods: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity, length and repetition rate. The acoustic signal of single proton pulses was measured by different PZT-based US detectors (3.5 MHz and 10 MHz central frequencies). For tomography a 64 channel US detector array was used and moved along the ion track by a remotely controlled motor stage. Results: A clear signal of the Bragg peak was visible for an energy deposition as low as 10{sup 12} eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Range measurements were reproducible within +/− 20 micrometer and agreed well with Geant4 simulations. The tomographic reconstruction does not only allow to measure the ion range but also the beam spot size at the Bragg peak position. Conclusion: Range verification by acoustic means is a promising new technique for treatment modalities where the tumor can be localized by US imaging. Further improvement of sensitivity is required to account for higher attenuation of the US signal in tissue, as well as lower energy density in the Bragg peak in realistic treatment cases due to higher particle energy and larger spot sizes. Nevertheless, the acoustic range verification approach could offer the possibility of combining anatomical US imaging with Bragg Peak imaging in the near future. The work was funded by the DFG cluster of excellence Munich Centre for Advanced Photonics (MAP)

60 APPLIED LIFE SCIENCES↗