Search NASA⌕ Search

SEARCH · Search NASA

Results for “Profiling optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Controlling magnetism and transport at perovskite cobaltite interfaces via strain-tuned oxygen vacancy ordering

Complex oxides such as perovskite cobaltites exhibit rich phenomena at interfaces due to the complex interplay between their structural, defect, electronic, and magnetic degrees of freedom. Here, we study this interplay here in the ferromagnetic metallic cobaltite La 1−𝑥 ⁢Sr 𝑥⁢ CoO 3−𝛿 , using specific substrates to vary both the heteroepitaxial strain (compressive vs tensile) and growth orientation ((001) vs (110)). Transmission electron microscopy, electron energy-loss spectroscopy, high-resolution X-ray diffraction, magnetometry, polarized neutron reflectometry, and electronic magnetotransport measurements are applied. Lattice mismatch and growth orientation are found to enable the precise control of interfacial oxygen vacancy ordering in La 1−𝑥⁢ Sr 𝑥 ⁢CoO 3−𝛿 , thus dictating strain relaxation and oxygen vacancy depth profiles, in turn controlling thickness-dependent magnetic and electronic properties. In particular, compressive strain and (110) orientations minimize deleterious magnetic/electronic dead layer effects, leading to the optimization of interfacial magnetism and transport. Strain and orientation tuning of oxygen vacancy ordering are thus established as powerful means to control physical properties at cobaltite-based interfaces, relevant to several fields.

36 MATERIALS SCIENCE↗

Coordinative Voltage Control Strategy with Multiple Resources for Distribution Systems of High PV Penetration

This paper presents an optimal voltage control methodology with coordination among different voltage-regulating resources, including controllable loads, distributed energy resources such as energy storage and photovoltaics (PV), and utility voltage-regulating devices such as voltage regulators and capacitors. The proposed methodology could effectively tackle the overvoltage and voltage regulation device distortion problems brought by high penetrations of PV to improve grid operation reliability. A voltage-load sensitivity matrix and voltage-regulator sensitivity matrix are used to deploy the resources along the feeder to achieve the control objectives. Mixed-integer nonlinear programming is used to solve the formulated optimization control problem. The methodology has been tested on the IEEE 123-feeder test system, and the results demonstrate that the proposed approach could improve the voltage profile of distribution system operation.

14 SOLAR ENERGY↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Search for signatures of sterile neutrinos with Double Chooz

We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e. comparing the data to the model prediction of disappearance in a data-to-data comparison of the two respective detectors. The analysis is optimized for a model of three active and one sterile neutrino. It is sensitive in the typical mass range ${5 \times 10^{-3}}\,\mathrm{eV}^2 \lesssim \varDelta m^2_{41} \lesssim {3 \times 10^{-1}}\,\mathrm{eV}^2$ for mixing angles down to $\sin ^2 2\theta _{14} \gtrsim {0.02}$. No significant disappearance additionally to the conventional disappearance related to $\theta _{13}$ is observed and correspondingly exclusion bounds on the sterile mixing parameter $\theta _{14}$ as a function of $\varDelta m^2_{41}$ are obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of a Bluff Body on a Pressurized Oxy-fuel Flame

Designing an effective burner is vital for the development of pressurized oxy-fuel combustion technologies. In the present work, turbulent jet diffusion burners are adopted for a pressurized oxy-combustor, with a bluff-body employed to create a recirculation zone, thereby stabilizing the flame in such a combustor. The objective of this numerical study is to perform a systematic analysis of the characteristics of such a pressurized non-premixed flame. Specifically, a 15-bar pressurized oxy-fuel combustor of power 100 kWth is modeled by means of the Ansys FLUENT commercial platform, using the Reynolds-averaged Navier-Stokes (RANS) approach. The present work focuses on identifying the aerothermodynamic features of the pressurized oxy-fuel burner with a disk-shape bluff-body. It is shown that the fuel-to-oxidizer stream momentum ratio has a great impact on the temperature profile of the down-fired, co-axial, pressurized oxy-coal, diffusion flame. A parametric study of the blockage ratio of the burner identifies an optimal range for this pressurized burner.

Li, Lei↗

Optimum Injector Parameters for Thermoacoustic Stability in a Multi-Nozzle Can Combustion System

Abstract High-frequency transverse instabilities are an important concern in can combustor configurations. In these configurations which are typically operated with multiple injectors around a central injector, each injector is subjected to different parts of the acoustic mode shape and thus respond differently for the same instability mode. Recent work by the author has modeled the response of premixed flames to excitation by natural high-frequency transverse modes in a can combustor both in the center and outer nozzles. The stability of these acoustically non-compact flames was assessed using the Rayleigh criterion (Rayleigh Integral denoted as RI) and not the overall unsteady heat release as is the case for compact flames. Several key control parameters were studied, namely — flame angle, swirling strength, nozzle location. For non-axisymmetric modes such as the commonly occurring 1-T mode, both radial and azimuthal offsets of the nozzle location affected stability. The framework was applied to an optimization study to identify the optimal combination of parameters that minimizes RI for the different nozzles in the multi-nozzle system. In this study, a N-around-1 configuration was studied, and the results indicated that the different nozzles needed to be operated at different flame angles and swirl numbers to result in an overall minimum RI. However, the specific response of the different injectors was not considered. The helical mode distribution at each injector varies as we azimuthally go around the combustor’s injector distribution and thus the most amplified mode and the resulting flame response would be different. To minimize RI, it is important to determine the injector configurations that result in a hydrodynamic profile that minimizes the individual RI for each nozzle. The resulting relationship between the injector’s flow and local hydrodynamics can then be used in a hydrodynamics study of an individual injector so that the most optimal injector is chosen depending on its location in the combustor dump plane.

Acharya, Vishal↗

Development of Multiresolution Capabilities for the Holistic Energy Resource Optimization Network (HERON) tool A progress update

INL researchers work on technoeconomic analyses for integrated energy systems (IES) using the Framework for Optimization of ResourCes and Economics (FORCE). Within FORCE, researchers use the Holistic Energy Resource Optimization Network (HERON) tool to conduct optimization of grid portfolios under uncertain market conditions. These optimizations determine optimal capacities for all IES components and strategies for resource dispatch which maximize some economic metric (e.g., net present value). Resource dispatch occurs on finer timescales (typically hours) and thus are asked to respond to a given time series (e.g. hourly load demand profiles for a grid, or pre-determined electricity prices). Volatile and complex bidding dynamics as well as poorly forecasted weather events within deregulated markets add uncertainty to the time series; FORCE can address this uncertainty by training a reduced order model on historical time series and generate unique synthetic time series which represent individual scenarios or realizations of the market. The IES configuration can be simulated under these different sampled realizations and a stochastic optimization is conducted which optimizes the expected value of the desired economic metric. The training of a synthetic time series generator is limited by the chosen time resolution; dynamics can occur on different time scales. Seasonal demand trends can dominate faster dynamical events (such as power outages from certain sectors or severe weather events) which might not get captured correctly by the trained model. In this report, we investigate different ways of addressing the training and generation of time series on multiple time scales using three main algorithms: wavelet decomposition, dynamic mode decomposition, and generative adversarial networks for time series. We demonstrate a time series analysis that yields information on not just the frequency space but also temporal space: where a fast Fourier transform can provide what frequencies dominate, the new algorithms can provide when the frequencies dominate as well. These analyses can help improve IES optimization by allowing researchers to couple simulations at different timescales when it is most needed - seasonal, day-ahead, and real time optimization - with greater computational efficiency. Future work will include implementation of a subset of the proposed algorithms into the FORCE toolset and application of these analyses into multiple timescale optimization.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Fast Spectrum Test Loop at the Advanced Test Reactor

The United States currently has no infrastructure to provide a fast neutron flux for research purposes. With the increased interest in Sodium Fast Reactor (SFR) technology, this type of infrastructure is necessary for further development of key components such as Versatile Test Reactor. The purpose of this research is to characterize the thermal hydraulics of a test loop capable of providing SFR like operating conditions. This includes showcasing feasibility in mechanical design, reaching a high fast to thermal neutron flux ratio ideally near 15, an inlet temperature of 600 K, a temperature increase of 50 K from inlet to outlet, and test chamber radial temperature profiles similar to SFR fuel rods. Existing infrastructure must be used to provide the neutron flux for the test loop, and it was decided that the Advanced Test Reactor (ATR) was the optimal choice due to its availability and previous work conducted similar to this project. To achieve the goals of this project, several mechanical designs were put forward with the most feasible design being chosen. The neutronics and thermal hydraulics analysis were conducted in tandem, with an iterative process used to maximize efficiency of both systems. Analysis of the neutronics system was done using Attila and MCNP while the thermal hydraulic analysis was done using RELAP5. This document outlines the thermal hydraulic analysis, though it includes the results from the mechanical design and neutronics analysis. The loop design includes a primary system with molten sodium, a set of “booster fuel plates” to increase the fast flux within the test section, a water system to cool the booster fuel plates, a helium system to separate the sodium and water systems, and a thermal neutron shield to decrease the thermal flux. Each of these systems is modeled in the neutronics and thermal hydraulic analyses. The RELAP5 model showcased the feasibility of the design proposed by this report. For all designs tested, the desired 50 K temperature increase from inlet to outlet was reached. The fuel rod radial temperature profile was lower than was expected, likely due to a lower rod thermal power than expected. A parametric study was also conducted to characterize the system with three fuel pins. This study showed the effect of thermal power, fluid pressure, fluid velocity, and inlet temperature on the system. ©Copyright by Anton Higgins December 11, 2019 All Rights Reserved

99 GENERAL AND MISCELLANEOUS↗

Optimizing Deep Geothermal Drilling for Energy Sustainability in the Appalachian Basin

This study investigates the geological and geomechanical characteristics of the MIP 1S geothermal well in the Appalachian Basin to optimize drilling and address the wellbore stability issues encountered. Data from well logs, sidewall core analysis, and injection tests were used to derive elastic and rock strength properties, as well as stress and pore pressure profiles. A robust 1D-geomechanical model was developed and validated, correlating strongly with wellbore instability observations. This revealed significant wellbore breakout, widening the diameter from 12 ¼ inches to over 16 inches. Advanced technologies like Cerebro Force™ In-Bit Sensing were used to monitor drilling performance with high accuracy. This technology tracks critical metrics such as bit acceleration, vibration in the x, y, and z directions, Gyro RPM, stick-slip indicators, and bending on the bit. Cerebro Force™ readings identified hole drag caused by poor hole conditions, including friction between the drill string and wellbore walls and the presence of cuttings or debris. This led to higher torque and weight on bit (WOB) readings at the surface compared to downhole measurements, affecting drilling efficiency and wellbore stability. Optimal drilling parameters for future deep geothermal wells were determined based on these findings.

Environmental Sciences & Ecology↗

Soft Actor Critic Based Volt-VAR Co-optimization in Active Distribution Grids

Modern distribution networks are undergoing several technical challenges, such as voltage fluctuations, because of high penetration of distributed energy resources (DERs). This paper proposes a deep reinforcement learning (DRL)-based Volt VAR co-optimization technique for reducing voltage fluctuations as well as power loss under high penetration of DERs. In addition, the proposed approach minimizes the operational cost of the grid. A stochastic policy optimization based soft actor critic (SAC) agent is proposed to configure the optimal set-points of the reactive power outputs of the inverters. The performance of the proposed model is verified on the modified IEEE 34- and 123-bus systems and compared with a base case scenario with no reactive supply by inverters, and a local droop control approach. The results demonstrate that the proposed framework outperforms the conventional droop control method in improving the voltage profile, minimizing the network power loss, and reducing grid operational cost.

—Distribution grids, deep reinforcement learning, ↗

Dynamic real‐time optimization for a CO 2 capture process

Growing awareness of climate change has led to increased focus on new energy processes that mitigate generation of CO 2 , or provide for its efficient capture. To enable the development of these processes, advanced modeling and optimization platforms have been created. New capabilities among platforms include efficient solution strategies for online optimization problems. For real time, dynamic optimization of CO 2 capture processes, we demonstrate the application of the Python‐based Pyomo platform to facilitate realization of Moving Horizon Estimation and Nonlinear Model Predictive Control, through novel nonlinear optimization and sensitivity strategies. This capability allows large scale, first principle models to be applied for online optimization. Here, we introduce the Control and Adaptation with Predictive Sensitivity Enhancements (CAPRESE) framework to demonstrate this framework for advanced energy processes. Moreover, we present two case studies: profile tracking with detailed tray‐by‐tray distillation models and Bubbling Fluidized Bed reactors for CO 2 capture. © 2018 American Institute of Chemical Engineers AIChE J , 65: e16511 2019

Thierry, David↗

EReinit: Scalable and efficient fault-tolerance for bulk-synchronous MPI applications

Scientists from many different fields have been developing Bulk-Synchronous MPI applications to simulate and study a wide variety of scientific phenomena. Since failure rates are expected to increase in larger-scale future HPC systems, providing efficient fault-tolerance mechanisms for this class of applications is paramount. The global-restart model has been proposed to decrease the time of failure recovery in Bulk-Synchronous applications by allowing a fast reinitialization of MPI. However, the current implementations of this model have several drawbacks: they lack efficiency; their scalability have not been shown; and they require the use of the MPI profiling interface, which precludes the use of tools. Here, we present EReinit, an implementation of the global-restart model that addresses these problems. Our key idea and optimization is the co-design of basic fault-tolerance mechanisms such as failure detection, notification, and recovery between MPI and the resource manager in contrast to current approaches on which these mechanisms are implemented in MPI only. We demonstrate EReinit in three HPC programs and show that it is up to four times more efficient than existing solutions at 4,096 processes.

97 MATHEMATICS AND COMPUTING↗

Renewable electricity capacity planning with uncertainty at multiple scales

Abstract We formulate and compare optimization models of investment in renewable generation using a suite of social planning models that compute optimal generation capacity investments for a hydro-dominated electricity system where inflow uncertainty results in a risk of energy shortage. The models optimize the expected cost of capacity expansion and operation allowing for investments in hydro, geothermal, solar, wind, and thermal plant, as well as battery storage for smoothing load profiles. A novel feature is the integration of uncertain seasonal hydroelectric energy supply and short-term variability in renewable supply in a two-stage stochastic programming framework. The models are applied to data from the New Zealand electricity system and used to estimate the costs of moving to a 100% renewable electricity system by 2035. We also explore the outcomes obtained when applying different forms of CO 2 constraint that limit respectively non-renewable capacity, non-renewable generation, and CO 2 emissions on average, almost surely, or in a chance-constrained setting, and show how our models can be used to investigate the merits of a proposed pumped-hydro scheme in New Zealand’s South Island.

Ferris, Michael C.↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

Estimating the performance of lithium beam measurements of current density and electron density in an H-mode pedestal

The lithium beam is an effective diagnostic tool for investigation of stability and particle transport in the pedestal. It was used successfully to measure edge current density on DIII-D, achieving qualitative agreement with neoclassical models. Electron density profiles were also measured. Proposed upgrades will continue these measurements with higher reliability as well as explore edge current measurements using spectroscopy. The optics will be redesigned to optimize throughput and aperture broadening and to replace the photomultiplier tubes with avalanche photodiodes. Here, the new system will yield detailed measurements of the pedestal, complementing existing diagnostics for investigating pedestal stability, edge localized mode cycle, and particle transport through the pedestal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing foreground mitigation for CMB lensing with combined multifrequency and geometric methods

Here, a key challenge for current and upcoming cosmic microwave background lensing measurements is their sensitivity to biases from extragalactic foregrounds, such as Sunyaev-Zel'dovich signals or cosmic infrared background emission. Several methods have been developed to mitigate these lensing foreground biases, dividing broadly into multifrequency cleaning approaches and modifications to the estimator geometry, but how to optimally combine these methods has not yet been explored in detail. In this paper, we examine which combination of lensing foreground mitigation strategies is best able to reduce the impact of foreground contamination for a Simons Observatory-like experiment while preserving maximal signal-to-noise. Although the optimal combination obtained depends on whether bias reduction or variance reduction is prioritized and on whether polarization data is used, generally, we find that combinations involving both geometric (profile hardening, source hardening, or shear) and multifrequency (symmetric cleaning) methods perform best. For lensing power spectrum measurements from temperature (polarization and temperature), our combined estimator methods are able to reduce the bias below σ/4 or 0.3% (0.1%), a factor of 16 (30) lower than the standard quadratic estimator bias, at a modest signal-to-noise cost of only 18% (12%). In contrast, single-method foreground-mitigation approaches struggle to reduce the bias to a negligible level below σ/2 without incurring a large noise penalty. For upcoming and current experiments, our combined methods therefore represent a promising approach for making lensing measurements with negligible foreground bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Nuclear data covariances are critical input to determine upper sub-critical limits and to design experiments to increase it [Slides]

This presentation discusses how Upper Subcritical Limits (USL) are key parameters to determine operational limits in nuclear criticality safety evaluations. It also discusses an example of plutonium casting operation using tantalum at LANL PF-4. The Whisper tool at Los Alamos relies on many inputs, including covariance data, leading the presentation to ask if an existing benchmark data be used in Whisper to adjust nuclear data and covariances to justify a higher USL. If not, Whisper can be used to help design an optimal new benchmark experiment. The presentation also seeks to determine what the possible impacts are on USL and operational limits for plutonium casting. In conclusion, nuclear data covariances are used for by Whisper for: GSSL adjustment of nuclear data and covariances, identification of most similar existing benchmark experiments to application, simulation of Upper Subcritical Limit of application, and input to optimization techniques for designing most appropriate new benchmark experiment(s) to meet requirements. This requires a complete set of nuclear data covariances, benchmarks and k-effective sensitivity profiles (for both benchmarks and applications). The presentation concludes by asking if end users should trust results that depend on current covariance data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis

The First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis (aka the STEP 1 Project or the Project) aimed to (1) developed a brand-new web tool that could provide decision support through free, rapid techno-economic analysis of behind-the-meter solar+storage systems for industrial process heat and (2) conduct high-level analyses of the cost-competitiveness of the same systems across the US in key sectors. The STEP 1 web tool collects key location, land availability, thermal load profile, proccess heat temperature and media, and other key parameters through an easy-to-use user interface (UI). The UI was designed to meet the user at their level of understanding by minimizing the number of required inputs as much as possible while including options for more nuanced inputs if the user desires. STEP 1 advises users on which solar thermal tehcnologies that could fit their needs based on the inputs provided (namely process media and temperature). The tool can model a wide range of solar thermal technologies including flat plate collectors, evacuated tubes, parabolic troughs, linear Fresnel, and molten salt towers all with corresponding thermal energy storage (TES) - solar PV with resistive heating and TES is also included. Once the parameters are collected, a nominal thermal energy production profile for the facility's location is generated using NREL's System Advisory Model (SAM) and then passed to a modified version of NREL's REopt platform to optimize the size (capacity) and dispatch of the solar+storage system to minimize lifecycle costs subject to energy balance, fuel and electricity rates, emission reductions goals, and other constraints. This entire process takes less than 20 minutes, is completely free, requires zero coding skills, and provides the user with a high-level assessment on the techno-economic feasability of deploying solar+storage systems for their energy needs. In addition to the development of the STEP 1 web tool, the project completed two complementary analyses focused on leveraging the backend code of STEP 1, public industrial facility locations and fuel consumption data, and key sector information to assess the economic opportunity of reducing fuel costs at various levels of capacity factor around the US. Both analyses found that there are key markets, locations, industrial sectors (namely food and beverage), and degrees of offset where solar thermal technologies could be cost-effectively deployed, highlighting a key market entry point for these technologies, and assessing deployment potential. In summary, the STEP 1 project improved the opportunities for solar+storage systems to expand into the industrial process heat market through breaking down barriers to assessing these technologies.

14 SOLAR ENERGY↗