Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Quantitative elemental imaging in eukaryotic algae

Abstract All organisms, fundamentally, are made from the same raw material, namely the elements of the periodic table. Biochemical diversity is achieved by how these elements are utilized, for what purpose, and in which physical location. Determining elemental distributions, especially those of trace elements that facilitate metabolism as cofactors in the active centers of essential enzymes, can determine the state of metabolism, the nutritional status, or the developmental stage of an organism. Photosynthetic eukaryotes, especially algae, are excellent subjects for quantitative analysis of elemental distribution. These microbes utilize unique metabolic pathways that require various trace nutrients at their core to enable their operation. Photosynthetic microbes also have important environmental roles as primary producers in habitats with limited nutrient supplies or toxin contaminations. Accordingly, photosynthetic eukaryotes are of great interest for biotechnological exploitation, carbon sequestration, and bioremediation, with many of the applications involving various trace elements and consequently affecting their quota and intracellular distribution. A number of diverse applications were developed for elemental imaging, allowing subcellular resolution, with X-ray fluorescence microscopy (XFM, XRF) being at the forefront, enabling quantitative descriptions of intact cells in a non-destructive method. This Tutorial Review summarizes the workflow of a quantitative, single-cell elemental distribution analysis of a eukaryotic alga using XFM.

59 BASIC BIOLOGICAL SCIENCES↗

Comparative study of bulk and nano-structured mesoporous SnO 2 electrodes on the electrochemical performances for next generation Li rechargeable batteries

For next generation Li-ion batteries, advanced electrode materials with high energy densities are mightily important issue. Since the partial oxidation of Sn with Li 2 O to form SnO x was demonstrated upon delithiation in SnO 2 anode, the additional conversion reaction has contributed that the theoretical capacity of SnO 2 can be extended from 783 to 1494 mAh g -1 . Herein, with the design of additional conversion reaction, we discuss key factors for high electrochemical performances of the SnO 2 anodes through comparative analysis between nano-structured mesoporous SnO 2 and conventional bulk SnO 2 , based on synchrotron radiation-based techniques, quantitative analysis of extended X-ray absorption fine structure spectra, and bond strength calculation. In this way, we demonstrate that the mesoporous SnO 2 has a nano-engineering structure, inducing the facilitated electrochemical reaction and the weak Sn-O bond strength that would have an advantage in the additional conversion reaction as well as a void structure, relieving the severe volume changes during lithiation/delithiation. Consequently, excellent electrochemical performance is obtained in the mesoporous SnO 2 . Furthermore, insight from this research enables important advance in the development of metal oxide-based anode materials by making irreversible reaction reversible, providing a realizable strategy for the design and creation of high-energy storage devices.

25 ENERGY STORAGE↗

SU-E-T-771: Two Dimensional Raman Mapping of Carbon Bonds of Radiochromic Films: An Approach to Micro-Dosimetry

Purpose: To study a feasibility of micro-dosimetry with high dose-sensitivity and resolution using two-dimensional Raman mapping on the basis of carbon bonds concentration of radiochromic films Methods: Unlaminated EBT3 films with the purpose of maximal Raman data acquisition were irradiated by 6 MV beam from 5 MU to 1000 MU at the reference condition. Each film was irradiated with shielding material of lead blocking on the half of film as well as the jaw open in half for distinct dose contrast. Raman peaks of 2070 cm-1, 2095 cm-1, and 2115 cm-1 were major subjects to study, which are assumed to be the spectroscopy of carbon triple bonds of monomers, carbon double bonds of polymers, and carbon triple bonds of polymers, respectively. Laser exposure for Raman spectroscopy generated peak’s trend due to polymerization by laser output and this trend was utilized to find out basic peaks related to polymerization process. The relative dose contrast in each one film was detected by Raman spectroscopy with the aid of an auto-scanning stage, comparing the dose contrast between non-irradiated area and irradiated area. Raman spatial resolution was enhanced up to 20 micrometers, assuming the spatial uniformity of radio¬active rod-shaped LiPCDA crystals. An optical scanner with 9600 dpi was used to scan the red-channel intensity to read the dose contrast for 5 MU delivered film. Results: The peak intensity for Raman wavenumber of 2070 cm-1 was used for mapping since it reflected the different peak intensities based on polymerization degree by irradiation. Dose contrast from 1000MU to 5 MU was distinguished by Raman mapping analysis, whereas optical intensity of red-channel didn’t show any difference. Conclusion: In consideration of laser effect, the quantitative analysis based on raw data of Raman mapping could provide more statistically reliable dosimetry than point measurements.

60 APPLIED LIFE SCIENCES↗

The use of ultrasonic property measurements as the basis for finite element analysis of composite materials

In this work, the use of ultrasonic property measurements as the basis for finite element analysis of full scale composite components is presented. The approach utilizes multiple velocity measurements at oblique angles of incidence and quantitative analysis of radiographic images for the local determination of each of the nine orthotropic moduli in a woven carbon-carbon composite. These values were then used as input into a finite element code (NASTRAN) to analyze the response of the material to load: here, diametric compression. The predicted response was then compared with strain gage results at several locations to validate the approach.

Madaras, E. I.↗

Investigation of Carbon Fiber Architecture in Braided Composites Using X-Ray CT Inspection

During the fabrication of braided carbon fiber composite materials, process variations occur which affect the fiber architecture. Quantitative measurements of local and global fiber architecture variations are needed to determine the potential effect of process variations on mechanical properties of the cured composite. Although non-destructive inspection via X-ray CT imaging is a promising approach, difficulties in quantitative analysis of the data arise due to the similar densities of the material constituents. In an effort to gain more quantitative information about features related to fiber architecture, methods have been explored to improve the details that can be captured by X-ray CT imaging. Metal-coated fibers and thin veils are used as inserts to extract detailed information about fiber orientations and inter-ply behavior from X-ray CT images.

braided composites↗

Variation Principles and Applications in the Study of Cell Structure and Aging

In this report we have attempted to show that "some reality lies concealed in biological variation". This "reality" has its principles, laws, mechanisms, and rules, only a few of which we have sketched. A related idea we pursued was that important information may be lost in the process of ignoring frequency distributions of physiological variables (as is customary in experimental physiology and gerontology). We suggested that it may be advantageous to expand one's "statistical field of vision" beyond simple averages +/- standard deviations. Indeed, frequency distribution analysis may make visible some hidden information not evident from a simple qualitative analysis, particularly when the effect of some external factor or condition (e.g., aging, dietary chemicals) is being investigated. This was clearly illustrated by the application of distribution analysis in the study of variation in mouse liver cellular and fine structure, and may be true of fine structural studies in general. In living systems, structure and function interact in a dynamic way; they are "inseparable," unlike in technological systems or machines. Changes in fine structure therefore reflect changes in function. If such changes do not exceed a certain physiologic range, a quantitative analysis of structure will provide valuable information on quantitative changes in function that may not be possible or easy to measure directly. Because there is a large inherent variation in fine structure of cells in a given organ of an individual and among individuals, changes in fine structure can be analyzed only by studying frequency distribution curves of various structural characteristics (dimensions). Simple averages +/- S.D. do not in general reveal all information on the effect of a certain factor, because often this effect is not uniform; on the contrary, this will be apparent from distribution analysis because the form of the curves will be affected. We have also attempted to show in this chapter that similar general statistical principles and mechanisms may be operative in biological and technological systems. Despite the common belief that most biological and technological characteristics of interest have a symmetric bell-shaped (normal or Gaussian) distribution, we have shown that more often than not, distributions tend to be asymmetric and often resemble a so-called log-normal distribution. We saw that at least three general mechanisms may be operative, i.e., nonadditivity of influencing factors, competition among individuals for a common resource, and existence of an "optimum" value for a studied characteristic; more such mechanisms could exist.

Economos, Angelos C.↗

Solving disorder in (3D) real space: a comparative study of the three-dimensional difference pair distribution function and atomic resolution holography reconstructions

The quantitative analysis of local ordering principles in disordered crystalline systems has gained much attention over the past few years, as it is often considered crucial for optimizing material functionality. This development has been driven by significant advancements in computational and experimental methods, which have led to the establishment and widespread use of various analytical techniques. In this study, we perform model calculations to compare the effectiveness of atomic resolution holography and three-dimensional difference pair distribution function analysis (3D-ΔPDF). Using Cu 3 Au as a model system, we demonstrate an approach to derive local order parameters quantitatively and show that both techniques are well suited to quantifying chemical short-range order correlations and local bond-distance variations. By evaluating the strengths and limitations of both techniques, we advocate for their combined use to solve complex short-range order problems accurately.

3D-ΔPDF↗

Outline of a new approach to the analysis of complex systems and decision processes.

Development of a conceptual framework for dealing with systems which are too complex or too ill-defined to admit of precise quantitative analysis. The approach outlined is based on the premise that the key elements in human thinking are not numbers, but labels of fuzzy sets - i.e., classes of objects in which the transition from membership to nonmembership is gradual rather than abrupt. The approach in question has three main distinguishing features - namely, the use of so-called 'linguistic' variables in place of or in addition to numerical variables, the characterization of simple relations between variables by conditional fuzzy statements, and the characterization of complex relations by fuzzy algorithms.

Zadeh, L. A.↗

Assessment of drug-induced arrhythmic risk using limit cycle and autocorrelation analysis of human iPSC-cardiomyocyte contractility

Cardiac safety assays incorporating label-free detection of human stem-cell derived cardiomyocyte contractility provide human relevance and medium throughput screening to assess compound-induced cardiotoxicity. In an effort to provide quantitative analysis of the large kinetic datasets resulting from these real-time studies, we applied bioinformatic approaches based on nonlinear dynamical system analysis, including limit cycle analysis and autocorrelation function, to systematically assess beat irregularity. The algorithms were integrated into a software program to seamlessly generate results for 96-well impedance-based data. Our approach was validated by analyzing dose- and time-dependent changes in beat patterns induced by known proarrhythmic compounds and screening a cardiotoxicity library to rank order compounds based on their proarrhythmic potential. We demonstrate a strong correlation for dose-dependent beat irregularity monitored by electrical impedance and quantified by autocorrelation analysis to traditional manual patch clamp potency values for hERG blockers. In addition, our platform identifies non-hERG blockers known to cause clinical arrhythmia. Our method provides a novel suite of medium-throughput quantitative tools for assessing compound effects on cardiac contractility and predicting compounds with potential proarrhythmia and may be applied to in vitro paradigms for pre-clinical cardiac safety evaluation. - Highlights: • Impedance-based monitoring of human iPSC-derived cardiomyocyte contractility • Limit cycle analysis of impedance data identifies aberrant oscillation patterns. • Nonlinear autocorrelation function quantifies beat irregularity. • Identification of hERG and non-hERG inhibitors with known risk of arrhythmia • Automated software processes limit cycle and autocorrelation analyses of 96w data.

60 APPLIED LIFE SCIENCES↗

libwfa: Wavefunction analysis tools for excited and open‐shell electronic states

Abstract An open‐source software library for wavefunction analysis, libwfa, provides a comprehensive and flexible toolbox for post‐processing excited‐state calculations, featuring a hierarchy of interconnected visual and quantitative analysis methods. These tools afford compact graphical representations of various excited‐state processes, provide detailed insight into electronic structure, and are suitable for automated processing of large data sets. The analysis is based on reduced quantities, such as state and transition density matrices (DMs), and allows one to distill simple molecular orbital pictures of physical phenomena from intricate correlated wavefunctions. The implemented descriptors provide a rigorous link between many‐body wavefunctions and intuitive physical and chemical models, for example, exciton binding, double excitations, orbital relaxation, and polyradical character. A broad range of quantum‐chemical methods is interfaced with libwfa via a uniform interface layer in the form of DMs. This contribution reviews the structure of libwfa and highlights its capabilities by several representative use cases. This article is categorized under: Software > Quantum Chemistry Theoretical and Physical Chemistry > Spectroscopy

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Man-machine analysis of translation and work tasks of Skylab films

An objective approach to determine the concurrent validity of computer-graphic models is real time film analysis. This technique was illustrated through the procedures and results obtained in an evaluation of translation of Skylab mission astronauts. The quantitative analysis was facilitated by the use of an electronic film analyzer, minicomputer, and specifically supportive software. The uses of this technique for human factors research are: (1) validation of theoretical operator models; (2) biokinetic analysis; (3) objective data evaluation; (4) dynamic anthropometry; (5) empirical time-line analysis; and (6) consideration of human variability. Computer assisted techniques for interface design and evaluation have the potential for improving the capability for human factors engineering.

Hosler, W. W.↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

Economic Impacts of a Wide Area Release of Anthrax

This analysis explores economic impacts that might result from a wide-area release of anthrax. The intent is not to provide a quantitative analysis of such a disaster, but to: 1. Define the general categories of economic impacts that the region should be concerned about; and, 2. Explore what types of private sector businesses or industries, if any, may have the greatest impact on speeding the economic recovery of the region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Faster, Better, Cheaper Approach to Space Missions: An Engineering Management Assessment

This paper describes, in viewgraph form, the faster, better, cheaper approach to space missions. The topics include: 1) What drives "Faster, Better, Cheaper"? 2) Why Space Programs are Costly; 3) Background; 4) Aerospace Project Management (Old Culture); 5) Aerospace Project Management (New Culture); 6) Scope of Analysis Limited to Engineering Management Culture; 7) Qualitative Analysis; 8) Some Basic Principles of the New Culture; 9) Cause and Effect; 10) "New Ways of Doing Business" Survey Results; 11) Quantitative Analysis; 12) Recent Space System Cost Trends; 13) Spacecraft Dry Weight Trend; 14) Complexity Factor Trends; 15) Cost Normalization; 16) Cost Normalization Algorithm; 17) Unnormalized Cost vs. Normalized Cost; and 18) Concluding Observations.

Hamaker, Joe↗

Extraterrestrial Molecular Indicators of Life Investigation (EMILI)

Future missions to Enceladus, Europa, Mars, and beyond may seek the molecular signs of extraterrestrial life through chemical analysis of acquired samples. Particularly on ocean worlds such as Enceladus and Europa, samples may contain trace ocean-borne molecular biosignatures of extant life that may or may not share similarities to those of terrestrial life. In situ analyses must be prepared to detect and characterize a wide range of possible molecular species, structures, and patterns, typically with exquisite sensitivity and within a complex, poorly-characterized planetary environment. The Extraterrestrial Molecular Indicators of Life Investigation (EMILI) is designed to meet or exceed the requirements of such missions for organic molecular analysis through a powerful combination of dual chemical separation and both optical and mass spectrometry detection techniques, realized in an integrated, compact instrument package fully compatible with anticipated flight resources and conditions. The full EMILI instrument combines two sample analysis subsystems to provide wide-ranging and complementary detection of organic compounds and inorganic salts. The Gas Analysis Processing System (GAPS) uses a chemical derivatization protocol with gas chromatography (GC) separation prior to detection in an ion trap mass spectrometer (ITMS) to enable full characterization of lower-polarity, volatile and semi-volatile molecules such as fatty acids and hydrocarbons. The Organic Capillary Electrophoresis ANalysis System (OCEANS) uses a liquid-based extraction protocol with CE separation to enable precise analysis of more water-soluble/polar compounds. OCEANS features a laser-induced fluorescence detection mode to perform ultra-sensitive quantitative analysis of chiral amino acids. In EMILI, OCEANS is additionally coupled to the same ITMS through a novel electrospray ionization interface. The common ITMS allows EMILI to identify and cross-correlate molecular species and patterns, detected through either or both protocols, of molecular weights to over 1000 u, potentially even revealing complex biosignatures such as alien oligopeptides and informational polymers.

Europa↗

Method of assessing a lipid-related health risk based on ion mobility analysis of lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

Benner, W Henry↗

Aerosol preparation of intact lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

60 APPLIED LIFE SCIENCES↗

Determining the risk of cardiovascular disease using ion mobility of lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

59 BASIC BIOLOGICAL SCIENCES↗