Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

SU-F-T-539: Dosimetric Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy for Whole Brain Hippocampal Sparing Radiation Therapy Treatments

Purpose: To compare the treatment plan quality and dose gradient near the hippocampus between VMAT (RapidArc) and IMRT delivery techniques for whole brain radiation therapy. Methods: Fifteen patients were evaluated in this retrospective study. All treatments were planned on Varian Eclipse TPS, using 3-Arc VMAT and 9-Field IMRT, following NRG Oncology protocol NRG-CC001 guidelines evaluated by a single radiation oncologist. Prescribed doses in all plans were 30 Gy delivered over 10 fractions normalized to a minimum of 100% of the dose covering 95% of the target volume. Identical contour sets and dose-volume constraints following protocol guidelines were also applied in all plans. A paired t-test analysis was used to compare VMAT and IMRT plans. Results: NRG-CC001 protocol dose-volume constraints were met for all VMAT and IMRT plans. For the planning target volume (PTV), the average values for D2% and D98% were 6% lower and 4% higher in VMAT than in IMRT, respectively. The average mean and maximum hippocampus doses in Gy for VMAT vs IMRT plans were (11.85±0.81 vs. 12.24±0.56, p=0.10) and (16.27±0.78 vs. 16.59±0.71, p=0.24), respectively. In VMAT, the average mean and maximum chiasm doses were 3% and 1% higher than in IMRT plans, respectively. For the left optic nerve, the average mean and maximum doses were 10% and 5% higher in VMAT than in IMRT plans, respectively. These values were 12% and 3% for the right optic nerve. The average percentage of dose gradient around the hippocampus in the 0–5mm and 5–10mm abutted regions for VMAT vs. IMRT were (4.42%±2.22% /mm vs. 3.95%±2.61% /mm, p=0.43) and (4.54%±1.50% /mm vs. 4.39%±1.28% /mm, p=0.73), respectively. Conclusion: VMAT plans can achieve higher hippocampus sparing with a faster dose fall-off than IMRT plans. Though statistically insignificant, VMAT offers better PTV coverage with slightly higher doses to OARs.

60 APPLIED LIFE SCIENCES↗

Multigroup Radiation-Hydrodynamics with a High-Order, Low-Order Method

Recent efforts at Los Alamos National Laboratory to develop a moment-based, scale-bridging [or high-order (HO)–low-order (LO)] algorithm for solving large varieties of the transport (kinetic) systems have shown promising results. A part of our ongoing effort is incorporating this methodology into the framework of the Eulerian Applications Project to achieve algorithmic acceleration of radiationhydrodynamics simulations in production software. By starting from the thermal radiative transfer equations with a simple material-motion correction, we derive a discretely consistent energy balance equation (LO equation). We demonstrate that the corresponding LO system for the Monte Carlo HO solver is closely related to the original LO system without material-motion corrections. We test the implementation on a radiative shock problem and show consistency between the energy densities and temperatures in the HO and LO solutions as well as agreement with the semianalytic solution. We also test the approach on a more challenging two-dimensional problem and demonstrate accuracy enhancements and algorithmic speedups. This paper extends a recent conference paper by including multigroup effects.

42 ENGINEERING↗

Atomic-scale design of radiation-tolerant nanocomposites

Recent work indicates that materials with nanoscale architectures, such as nanolayered Cu-Nb composites and nanoscale oxide dispersion-strengthened steels, are both thermally stable and offer improved performance under irradiation. Current understanding of the atomic-level response of such materials to radiation yields insights into how controlling composition, morphology, and interface-defect interactions may further enable atomic-scale design of radiation-tolerant nanostructured composite materials. With greater understanding of irradiation-assisted degradation mechanisms, this bottom-up design approach may pave the way for creating the extreme environment—tolerant structural materials needed to meet the world's clean energy demand by expanding use of advanced fission and future fusion power.

36 MATERIALS SCIENCE↗

Radiation Dose-Volume Effects in Radiation-Induced Rectal Injury

The available dose/volume/outcome data for rectal injury were reviewed. The volume of rectum receiving >=60Gy is consistently associated with the risk of Grade >=2 rectal toxicity or rectal bleeding. Parameters for the Lyman-Kutcher-Burman normal tissue complication probability model from four clinical series are remarkably consistent, suggesting that high doses are predominant in determining the risk of toxicity. The best overall estimates (95% confidence interval) of the Lyman-Kutcher-Burman model parameters are n = 0.09 (0.04-0.14); m = 0.13 (0.10-0.17); and TD{sub 50} = 76.9 (73.7-80.1) Gy. Most of the models of late radiation toxicity come from three-dimensional conformal radiotherapy dose-escalation studies of early-stage prostate cancer. It is possible that intensity-modulated radiotherapy or proton beam dose distributions require modification of these models because of the inherent differences in low and intermediate dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of chlorination on the TlBr band edges for improved room temperature radiation detectors: Effect of chlorination on the TlBr band edges for radiation detectors

Thallium bromide (TlBr) crystals subjected to hydrochloric acid (HCl) chemical treatments have been shown to advantageously affect device performance and longevity in TlBr-based room temperature radiation detectors, yet the exact mechanisms of the improvements remain poorly understood. Here in this paper, we investigate the influence of several HCl chemical treatments on device-grade TlBr and describe the changes in the composition and electronic structure of the surface. Composition analysis and depth profiles obtained from secondary ion mass spectrometry (SIMS) identify the extent to which each HCl etch condition affects the detector surface region and forms of a graded TlBr/TlBr 1-x CL x surface heterojunction. Using a combination of X-ray photoemission spectroscopy (XPS) and hybrid density functional calculations, we are able to determine the valence band offsets, band gaps, and conduction band offsets as a function of Cl content over the entire composition range of TIBr 1-x C1 X . This study establishes a strong correlation between device process conditions, surface chemistry, and electronic structure with the goal of further optimizing the long-term stability and radiation response of TlBr-based detectors.

36 MATERIALS SCIENCE↗

Improvements in the Method of Radiation Anomaly Detection by Spectral Comparison Ratios

Algorithms for detecting illicit gamma radiation sources must respond to a wide variety of threat signatures and ignore a wider variety of clutter. Previously, we described the Nuisance-rejection Spectral Comparison Ratio Anomaly Detection (N-SCRAD) method for indicating the presence of threat sources during mobile search operations. Our method relies on the formulation of radiation alarm test statistics applied to detector counts in numerous spectral regions of interest and our test statistics are standardized by local estimates of background variability. In this work we present a new automated procedure for selecting test statistics and specifying the regions of interest based on minimizing detectable count rates of prototype threat spectra at a specified false positive rate using simulated annealing. The new procedure can be applied to configuring the detection algorithm when the prototype threats are many and diverse without significantly compromising the detection sensitivity to any one of them. N-SCRAD makes use of estimates of background variability obtained during a search from prior measurements of background. In applications such estimates made purely from past measurements sometimes do not extrapolate well to current conditions. In this work we present a new method for correcting those estimates to current conditions of the total count rate. We demonstrate that the correction lowers detection thresholds for a specified false positive rate, enabling greater sensitivity to targets. The two proposed improvements to N-SCRAD maximize detection power for the expected variety of possible threats while reducing or maintaining the false positive rate.

Anomaly detection, Gamma-ray spectroscopy, Radiati↗

Does Hormone Therapy Reduce Disease Recurrence in Prostate Cancer Patients Receiving Dose-Escalated Radiation Therapy? An Analysis of Radiation Therapy Oncology Group 94-06

Purpose: The purpose of this study was to evaluate the effect on freedom from biochemical failure (bNED) or disease-free survival (DFS) by adding hormone therapy (HT) to dose-escalated radiation therapy (HDRT). Methods and Materials: We used 883 analyzable prostate cancer patients who enrolled on Radiation Therapy Oncology Group (RTOG) 94-06, a Phase I/II dose escalation trial, and whose mean planning target volume dose exceeded 73.8 Gy (mean, 78.5 Gy; maximum, 84.3 Gy). We defined biochemical failure according to the Phoenix definition. Results: A total of 259 men started HT 2 to 3 months before HDRT, but not longer than 6 months, and 66 men with high-risk prostate cancer received HT for a longer duration. At 5 years, the biochemical failure rates after HDRT alone were 12%, 18%, and 29% for low-, intermediate-, and high-risk patients, respectively (p < 0.0001). Cox proportional hazards regression analysis adjusted for covariates revealed that pretreatment PSA level was a significant factor, whereas risk group, Gleason score, T-stage, and age were not. When the patients were stratified by risk groups, the Cox proportion hazards regression model (after adjusting for pretreatment PSA, biopsy Gleason score, and T stage) did not reveal a significant effect on bNED or DFS by adding HT to HDRT Conclusion: The addition of HT did not significantly improve bNED survival or DFS in all prostate cancer patients receiving HDRT, but did approach significance in high-risk patient subgroup. The result of this study is hypothesis generating and requires testing in a prospective randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Improved Model for Predicting Radiation Pneumonitis Incorporating Clinical and Dosimetric Variables;Lung cancer; Radiation pneumonitis; Dose-volume histogram; Angiotensin converting enzyme inhibitor

Purpose: Single dose-volume metrics are of limited value for the prediction of radiation pneumonitis (RP) in day-to-day clinical practice. We investigated whether multiparametric models that incorporate clinical and physiologic factors might have improved accuracy. Methods and Materials: The records of 160 patients who received radiation therapy for non-small-cell lung cancer were reviewed. All patients were treated to the same dose and with an identical technique. Dosimetric, pulmonary function, and clinical parameters were analyzed to determine their ability to predict for the subsequent development of RP. Results: Twenty-seven patients (17%) developed RP. On univariate analysis, the following factors were significantly correlated with the risk of pneumonitis: fractional volume of lung receiving >5-20 Gy, absolute volume of lung spared from receiving >5-15 Gy, mean lung dose, craniocaudal position of the isocenter, transfer coefficient for carbon monoxide (KCOc), total lung capacity, coadministration of angiotensin converting enzyme inhibitors, and coadministration of angiotensin receptor antagonists. By combining the absolute volume of lung spared from receiving >5 Gy with the KCOc, we defined a new parameter termed Transfer Factor Spared from receiving >5 Gy (TFS{sub 5}). The area under the receiver operator characteristic curve for TFS{sub 5} was 0.778, increasing to 0.846 if patients receiving modulators of the renin-angiotensin system were excluded from the analysis. Patients with a TFS{sub 5} <2.17 mmol/min/kPa had a risk of RP of 30% compared with 5% for the group with a TFS{sub 5} {>=}2.17. Conclusions: TFS{sub 5} represents a simple parameter that can be used in routine clinical practice to more accurately segregate patients into high- and low-risk groups for developing RP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of the Radiation Boost on Outcomes After Breast-Conserving Surgery and Radiation

Purpose: We examined the impact of radiation tumor bed boost parameters in early-stage breast cancer on local control and cosmetic outcomes. Methods and Materials: A total of 3,186 women underwent postlumpectomy whole-breast radiation with a tumor bed boost for Tis to T2 breast cancer from 1970 to 2008. Boost parameters analyzed included size, energy, dose, and technique. Endpoints were local control, cosmesis, and fibrosis. The Kaplan-Meier method was used to estimate actuarial incidence, and a Cox proportional hazard model was used to determine independent predictors of outcomes on multivariate analysis (MVA). The median follow-up was 78 months (range, 1-305 months). Results: The crude cosmetic results were excellent in 54%, good in 41%, and fair/poor in 5% of patients. The 10-year estimate of an excellent cosmesis was 66%. On MVA, independent predictors for excellent cosmesis were use of electron boost, lower electron energy, adjuvant systemic therapy, and whole-breast IMRT. Fibrosis was reported in 8.4% of patients. The actuarial incidence of fibrosis was 11% at 5 years and 17% at 10 years. On MVA, independent predictors of fibrosis were larger cup size and higher boost energy. The 10-year actuarial local failure was 6.3%. There was no significant difference in local control by boost method, cut-out size, dose, or energy. Conclusions: Likelihood of excellent cosmesis or fibrosis are associated with boost technique, electron energy, and cup size. However, because of high local control and rare incidence of fair/poor cosmesis with a boost, the anatomy of the patient and tumor cavity should ultimately determine the necessary boost parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Out-of-Field Dose and Its Constituent Components for Intensity-Modulated Radiation Therapy Versus Conformal Radiation Therapy: Implications for Carcinogenesis

Purpose: To investigate differences in scatter and leakage between 6-MV intensity-modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3DCRT); to describe the relative contributions of internal patient scatter, collimator scatter, and head leakage; and to discuss implications for second cancer induction. Methods and Materials: Dose was measured at increasing distances from the field edge in a water bath with a sloping wall (1) under full scatter conditions, (2) with the field edge abutting but outside the bath to prevent internal (water) scatter, and (3) with the beam aperture plugged to reflect leakage only. Results: Internal patient scatter from IMRT is 11% lower than 3DCRT, but collimator scatter and head leakage are five and three times higher, respectively. Ultimately, total scattered dose is 80% higher with IMRT; however this difference is small in absolute terms, being 0.14% of prescribed dose. Secondary dose from 3DCRT is mostly due to internal patient scatter, which contributes 70% of the total and predominates until 25 cm from the field edge. For IMRT, however, machine scatter/leakage is the dominant source, contributing 65% of the secondary dose. Internal scatter predominates for just the first 10 cm from field edge, collimator scatter for the next 10 cm, and head leakage thereafter. Conclusions: Out-of-field dose is 80% higher with IMRT, but differences are tiny in absolute terms. Reductions in internal patient scatter with IMRT are outweighed by increased machine scatter and leakage, at least for small fields. Reductions from IMRT in dose to tissues within the portals and in internal scatter, which predominates close to the field edge, means that calculations based solely on dose to distant tissues may overestimate carcinogenic risks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Therapy Oncology Group Protocol 02-29: A Phase II Trial of Neoadjuvant Therapy With Concurrent Chemotherapy and Full-Dose Radiation Therapy Followed by Surgical Resection and Consolidative Therapy for Locally Advanced Non-small Cell Carcinoma of the Lung

Purpose: To evaluate mediastinal nodal clearance (MNC) rates after induction chemotherapy and concurrent, full-dose radiation therapy (RT) in a phase II trimodality trial (Radiation Therapy Oncology Group protocol 0229). Patients and Methods: Patients (n=57) with stage III non-small cell lung cancer (pathologically proven N2 or N3) were eligible. Induction chemotherapy consisted of weekly carboplatin (AUC = 2.0) and paclitaxel 50 mg/m{sup 2}. Concurrent RT was prescribed, with 50.4 Gy to the mediastinum and primary tumor and a boost of 10.8 Gy to all gross disease. The mediastinum was pathologically reassessed after completion of chemoradiation. The primary endpoint of the study was MNC, with secondary endpoints of 2-year overall survival and postoperative morbidity/mortality. Results: The grade 3/4 toxicities included hematologic 35%, gastrointestinal 14%, and pulmonary 23%. Forty-three patients (75%) were evaluable for the primary endpoint. Twenty-seven patients achieved the primary endpoint of MNC (63%). Thirty-seven patients underwent resection. There was a 14% incidence of grade 3 postoperative pulmonary complications and 1 30-day, postoperative grade 5 toxicity (3%). With a median follow-up of 24 months for all patients, the 2-year overall survival rate was 54%, and the 2-year progression-free survival rate was 33%. The 2-year overall survival rate was 75% for those who achieved nodal clearance, 52% for those with residual nodal disease, and 23% for those who were not evaluable for the primary endpoint (P=.0002). Conclusions: This multi-institutional trial confirms the ability of neoadjuvant concurrent chemoradiation with full-dose RT to sterilize known mediastinal nodal disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗