Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Radiation and Fault Tolerance for Neuromorphic Computing

• The solar wind emanating from the sun is a stream of energetic electrons and protons and ions that are the primary ionizing radiation contributions. • The Earth’s magnetosphere significantly reduces radiation exposure and mutes the effects of solar flares out to 65K Km orbital altitude. • The radiation environment is highly dependent upon mission profile: for example geosynchronous orbits can see 50 times the radiation dose of a polar orbit due to reduction of atmospheric/magnetospheric shielding. • In LEO, the magnetosphere shields the Earth by creating trapped Van Allen radiation belts consisting of electrons and protons, which create a challenging radiation environment confined to specific regions. • Even for LEO, radiation dose can vary by a factor of 30 or more from a quiet sun to a solar flare. • Galactic Cosmic Rays (GCRs) are also present at very high energy, but at low rates. • Radiation effects on semiconductors are highly dependent upon particles species, energy and flux. • Therefore, radiation tolerance requirements will vary with mission profile and duration.

Space Radiation↗

Chelation Model Validation: Modeling of a Plutonium-238 Inhalation Incident Treated with DTPA at Los Alamos National Laboratory

Accidental inhalation of plutonium at the workplace is a non-negligible risk, even when rigorous safety standards are in place. The intake and retention of plutonium in the human body may be a source of concern. Thus, if there is a suspicion of a significant intake of plutonium, medical countermeasures such as chelation treatment may be administered to the worker. The present work aimed to interpret the bioassay data of a worker involved in an inhalation incident due to a glovebox breach at Los Alamos National Laboratory’s plutonium facility. The worker was treated with intravenous injections of calcium salts of diethylenetriaminepentaacetic acid (DTPA) in an attempt to reduce the amount of plutonium from the body and therefore reduce the internal radiation dose. It is well known in the internal dosimetry field that the administration of chelation treatment poses additional challenges to the dose assessment. Hence, a recently developed chelation model was used for the modeling of the bioassay data. The objectives of this work are to describe the incident, model the chelation-affected and non-affected bioassay data, estimate the plutonium intake, and assess the internal radiation dose.

238Pu↗

NMR-based Metabolomics Analysis of Liver from C57BL/6 Mouse Exposed to Ionizing Radiation

The health effects of exposing to ionizing radiation are attracting great interest in the space exploration community and patients considering radiotherapy. However, the impact to metabolism after exposure to high dose radiation has not yet been clearly defined in livers. In the present study, 1H nuclear magnetic resonance (NMR) based metabolomics combined with multivariate data analysis are applied to study the changes of metabolism in the liver of C57BL/6 mouse after whole body exposure to either gamma (3.0 and 7.8 Gy) or proton (3.0 Gy) radiation. Principal component analysis (PCA) and orthogonal projection to latent structures analysis (OPLS) are employed for classification and identification of potential biomarkers associated with gamma and proton irradiation. The results show that the radiation exposed groups can be well separated from the control group. At the same radiation dosage, the group exposed to proton radiation is well separated from the group exposed to gamma radiation, indicating different radiation sources induce different alterations based on metabolic profiling. Common to both gamma and proton radiation at the high radiation doses studied in this work, compared with the control groups the concentrations of choline, O-phosphocholine and trimethylamine N-oxide are decreased statistically, while those of glutamine, glutathione, malate, creatinine, phosphate, betaine and 4-hydroxyphenylacetate are statistically and significantly elevated after exposure to radiation. Since these altered metabolites are associated with multiple biological pathways, the changes suggest that the exposure to radiation induce abnormality in multiple biological pathways. In particular, metabolites such as 4-hydroxyphenylacetate, betaine, glutamine, choline and trimethylamine N-oxide may be good candidates of pre-diagnose biomarkers for ionizing radiation in liver.

Xiao, Xiongjie↗

Broadly Applicable Dose Model for Radiotherapy Beams from 6-25 MV

The goal of modern external beam radiotherapy is to deliver a highly targeted radiation dose to a specified treatment volume while sparing the healthy surrounding tissue as much as possible. However, some healthy tissue radiation exposure is unavoidable. Healthy tissue in the margin of the treatment field will receive absorbed doses on the order of the prescribed dose, and tissue far out of field will receive stray dose from scattered and leakage radiation. These doses can lead to late effects such as secondary cancers both near the treatment field and far out of field in tissues only receiving stray radiation dose. Many researchers have investigated algorithms to model absorbed dose from external beam photon radiation therapy; however, none of these works have fully addressed the stray dose far from the treatment field. The AAPM Task Group Report No. 36 described three main sources of stray radiation from external beam radiation therapy delivered with electron linear accelerators. Radiation scattered from the treatment head, known as head scatter, is primarily important within about 10 cm from the field edge. Patient scatter is an important source up to around 30 cm from the field edge. Finally, leakage radiation emanates from the treatment enclosure and predominates the stray radiation dose beyond about 30 cm. Monte Carlo simulations have been a useful research tool for modeling stray dose, but these methods have not found use in clinical settings due to their complexity and long computational times. The feasibility of analytical models to predict stray dose from radiation therapy has been supported by several works, but few attempts have been made at developing models accurate for both in-field and out-of-field doses. Jagetic and Newhauser reported on one such model that predicts absorbed dose from therapeutic, scatter, and leakage radiation with promising results. This model was validated at 6 MV for Conformal Radiation Therapy (CRT) beams from an Elekta linac. Intensity Modulated Radiation Therapy (IMRT) was not considered, and the model has not been tested at beam energies greater than 6 MV. Additionally, this model relies on proprietary, machine specific parameters, and so adapting the model for use on treatment units from other manufacturers is not straightforward. In this study we aim to test whether a physics-based analytical modeling approach is broadly applicable and if sufficient accuracy can be achieved without the need for proprietary, machine specific parameters. In order to accomplish this, a new analytical model was developed that does not rely on machine specific parameters, so that it can easily be trained on measurements from whatever treatment machine is available at a given clinic. This model was tested using measured data from a variety of treatment machines and techniques in the 6 MV to 25 MV energy interval. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

The effects of chronic, low doses of Ra-226 on cultured fish and human cells

Purpose: To determine the chronic low-dose radiation effects caused by α-particle radiation from {sup 226}Ra over multiple cell generations in CHSE/F fish cells and HaCaT human cells. Methods: CHSE/F cells and HaCaT cells were cultured in medium containing {sup 226}Ra to deliver the chronic low-dose α-particle radiation. Clonogenic assay was used to test the clonogenic survival fractions of cells with or without being exposed to radiation from {sup 226}Ra. Results: The chronic low-dose radiation from {sup 226}Ra does have effects on the clonogenic survival of CHSE/F cells and HaCaT cells. When CHSE/F cells were cultured in {sup 226}Ra-medium over 9 passages for about 134 days, the clonogenic surviving fractions for cells irradiated at dose rates ranging from 0.00066 to 0.66 mGy/d were significantly lower than that of cells sham irradiated. For HaCaT cells grown in medium containing the same range of {sup 226}Ra activity, the clonogenic surviving fraction decreased at first and reached the lowest value at about 42 days (8 passages). After that, the clonogenic survival began to increase, and was significantly higher than that of control cells by the end of the experimental period. Conclusion: The chronic, low-dose high LET radiation from {sup 226}Ra can influence the clonogenic survival of irradiated cells. CHSE/F cells were sensitized by the radiation, and HaCaT cells were initially sensitized but later appeared to be adapted. The results could have implications for determining risk from chronic versus acute exposures to radium. - Highlights: • Cells were exposed to chronic low-dose α-radiation from {sup 226}Ra in medium with {sup 226}Ra. • The clonogenic survival of CHSE/F cells decreased when exposed to {sup 226}Ra for 134 days. • The clonogenic survival of HaCaT cells decreased at first and then increased. • The doubling time of both cells were not affected by this kind of radiation.

54 ENVIRONMENTAL SCIENCES↗

Early-life atomic-bomb irradiation accelerates immunological aging and elevates immune-related intracellular reactive oxygen species

Reactive oxygen species (ROS) play an important role in immune responses; however, their excessive production and accumulation increases the risk of inflammation-related diseases. Although irradiation is known to accelerate immunological aging, the underlying mechanism is still unclear. To determine the possible involvement of ROS in this mechanism, we examined 10,023 samples obtained from 3752 atomic-bomb survivors in Hiroshima and Nagasaki, who participated in repeated biennial examinations from 2008 to 2016, for the effects of aging and radiation exposure on intracellular ROS (H 2 O 2 and O 2 •- ) levels, percentages of T-cell subsets, and the effects of radiation exposure on the relationship between cell percentages and intracellular ROS levels in T-cell subsets. The cell percentages and intracellular ROS levels in T-cell subsets were measured using flow cytometry, with both fluorescently labeled antibodies and the fluorescent reagents, carboxy-DCFDA and hydroethidine. The percentages of naïve CD4 + and CD8 + T cells decreased with increasing age and radiation dose, while the intracellular O 2 •- levels in central and effector memory CD8 + T cells increased. Additionally, when divided into three groups based on the percentages of naïve CD4 + T cells, intracellular O 2 •- levels of central and effector memory CD8 + T cells were significantly elevated with the lowest radiation dose group in the naïve CD4 + T cells. Thus, the radiation exposure-induced decrease in the naïve CD4 + T cell pool size may reflect decreased immune function, resulting in increased intracellular ROS levels in central and effector memory CD8 + T cells, and increased intracellular oxidative stress.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

MO-C-18C-01: Radiation Risks at Level of Few CT Scans: How Real?- Science to Practice

There are controversies surrounding radiation effects in human population in the range of radiation doses encountered by patients resulting from one to several CT scans. While it is understandable why the effects from low levels of diagnostic radiation are controversial, the situation is complicated by the media which may distort the known facts. There is need to understand the state of science regarding low-level radiation effects and also to understand how to communicate the potential risk with patients, the public and media. This session will seek to come to a consensus in order to speak with one voice to the media and the public. This session will review radiation effects known so far from a variety of exposed groups since the nuclear holocaust, provide clarification where effects are certain and where they are not, at what level extrapolation is the only way and at what level there is weak but agreeable acceptance. We will depict where and why there is agreement among organizations responsible for studying radiation effects, and how to deal with situations where effects are uncertain. Specific focus on radiation effects in children will be provided.Finally, the session will attempt to bridge the communication gap from the science to how to be an effective communicator with patients, parents, and media about ionizing radiation. Learning Objectives: To have a clear understanding about certainties and uncertainties of radiation effects at the level of a few CT scans To understand the results and limitations from 3 major pediatric CT scientific studies on childhood exposures published recently. To understand successful strategies used in risk communication.

60 APPLIED LIFE SCIENCES↗

Epidermal Homeostasis and Radiation Responses in a Multiscale Tissue Modeling Framework

The surface of skin is lined with several thin layers of epithelial cells that are maintained throughout life time by a small population of stem cells. High dose radiation exposures could injure and deplete the underlying proliferative cells and induce cutaneous radiation syndrome. In this work we propose a multiscale computational model for skin epidermal dynamics that links phenomena occurring at the subcellular, cellular, and tissue levels of organization, to simulate the experimental data of the radiation response of swine epidermis, which is closely similar to human epidermis. Incorporating experimentally measured histological and cell kinetic parameters, we obtain results of population kinetics and proliferation indexes comparable to observations in unirradiated and acutely irradiated swine experiments. At the sub-cellular level, several recently published Wnt signaling controlled cell-cycle models are applied and the roles of key components and parameters are analyzed. Based on our simulation results, we demonstrate that a moderate increase of proliferation rate for the survival proliferative cells is sufficient to fully repopulate the area denuded by high dose radiation, as long as the integrity of underlying basement membrane is maintained. Our work highlights the importance of considering proliferation kinetics as well as the spatial organization of tissues when conducting in vivo investigations of radiation responses. This integrated model allow us to test the validity of several basic biological rules at the cellular level and sub-cellular mechanisms by qualitatively comparing simulation results with published research, and enhance our understanding of the pathophysiological effects of ionizing radiation on skin.

Hu, Shaowen↗

X-ray photoelectron and mass spectroscopic study of electron irradiation and thermal stability of polytetrafluoroethylene

Polytetrafluoroethylene (PTFE) was subjected to 3 keV electron bombardment and then heated in vacuum to 300 C. The behavior of the material as a function of radiation dose and temperature was studied by X-ray photoelectron spectroscopy (XPS) of the surface and mass spectroscopy of the species evolved. A quantitative comparison of the radiation dose rate with that in other reported studies showed that, for a given total dose, the damage observed by XPS is greater for higher dose rates. Lightly damaged material heated to 300 C evolved saturated fluorocarbon species, whereas unsaturated fluorocarbon species evolved from heavily damaged material. After heating the heavily damaged material, those features in the XPS that were associated with damage diminished, giving the appearance that the radiation damage annealed. The apparent annealing of the radiation damage was found to be due to the covering of the network by saturated fragments that easily diffused through the decomposed material to the surface region upon heating.

Wheeler, Donald R.↗

Influence of tumor location on the intensity-modulated radiation therapy plan of helical tomotherapy

Given the design of the Helical TomoTherapy device, the patient's central axis is routinely aligned with the machine's rotational axis to prevent the patient's body from colliding with the machine walls. However, for treatment of tumors located away from the patient's central axis, this position may not be optimal as the adequate radiation dose may not reach the affected site. Our study aimed to investigate the influence of tumor location on dose quality and delivery efficiency of tomotherapy plans. A phantom and 15 patients were selected for this study. Two plans, A and B, were implemented for each case. In plan A, the patient's central axis was aligned with the machine's rotational axis, whereas in plan B, the center of the planning target volume (PTV) was aligned with the machine's rotational axis. Both plans were optimized with the same planning parameters, and the dose quality of the plans was evaluated using dosimetrics. The delivery efficiency was determined from delivery time and monitor units (MUs). A paired t-test or nonparametric Wilcoxon signed-rank test was performed for statistical comparison. In the phantom study, the median delivery times were 358 and 336 seconds for plans A and B, respectively, and this difference was significant (p = 0.005). In the patient study, the median delivery times were 348 and 317 seconds for plans A and B, respectively, and this difference was also significant (p = 0.001). The dose qualities of both plans for each patient were nearly identical. No significant differences were found in the conformal index, heterogeneity index, and mean dose delivered to normal tissue between the plans. Both phantom and patient studies showed that for normal-sized patients, the delivery time reduced as the distance between the PTV and the patient's central axis increased when the PTV center was aligned with the machine axis. In conclusion, aligning the PTV center with the machine's rotational axis by shifting the patient during tomotherapy reduces the delivery time without compromising the dose quality of intensity-modulated radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical Performance and Mesostructure Analysis of Proton-Irradiated Fused Filament Fabrication Acrylonitrile Butadiene Styrene Material

The use of fused filament fabrication (FFF) acrylonitrile butadiene styrene (ABS) and other thermoplastics in radiation environments is beginning to be studied as possible replacements for traditionally manufactured parts and tools. Interlayer adhesion within the mesostructure has been shown in published literature to be an integral component in the strength of FFF ABS. Research of irradiated 3D printed polymers has primarily focused on the influence of gamma irradiation on the mechanical properties of FFF ABS samples, without evaluating its impact on the mesostructure of the samples. The purpose of this paper is to understand the mechanical damage caused by proton radiation on FFF ABS samples through the evaluation of the mesostructure of the ABS samples. To achieve this objective, proton radiation at 40 MeV was applied to FFF ABS samples at radiation doses up to 1.0 MGy at a dose rate of 1 MGy/hr. Following the irradiation, tensile testing was performed on the samples. Here, the fractured surfaces of the tested samples were subsequently observed using a scanning electron microscope. The mechanical test results show an increase in the ultimate tensile strength (UTS) and a decrease in the ductility of the irradiated samples. Statistical analysis on the results shows that there is a statistically significant difference in the UTS and the ductility of unirradiated and 1.0 MGy irradiated samples and between irradiated samples and 1.0 MGy samples. In addition, the percentage elongation at break has statistically significant differences in the means between irradiated samples and 1.0 MGy samples. The UTS has statistically significant differences in the means between 0.1 MGy and 1.0 MGy. The difference in the means between the unirradiated and the 1.0 MGy samples is the most significant for both the UTS and elongation at break. The scanning electron microscopy (SEM) results indicated that interlayer adhesion improved as a function of radiation dose corresponding to the increase in tensile strength. The SEM results also showed that crazing and plastic deformation were reduced; aligning with the loss in ductility observed in the tensile tests results. The proton radiation is causing these mechanical and physical changes through two mechanisms: (1) dose rate effects on ionizing radiation-induced oxidative degradation; and (2) radiation heating effects of high energy (>1 MeV) charged particles.

electron microscopy↗

Interplanetary Radiation and Internal Charging Environment Models for Solar Sails

A Solar Sail Radiation Environment (SSRE) model has been developed for characterizing the radiation dose and internal charging environments in the solar wind. The SSRE model defines the 0.01 keV to 1 MeV charged particle environment for use in testing the radiation dose vulnerability of candidate solar sail materials and for use in evaluating the internal charging effects in the interplanetary environment. Solar wind and energetic particle instruments aboard the Ulysses spacecraft provide the particle data used to derive the environments for the high inclination 0.5 AU Solar Polar Imager mission and the 1.0 AU L1 solar sail missions. Ulysses is the only spacecraft to sample high latitude solar wind environments far from the ecliptic plane and is therefore uniquely capable of providing the information necessary for defining radiation environments for the Solar Polar Imager spacecraft. Cold plasma moments are used to derive differential flux spectra based on Kappa distribution functions. Energetic particle flux measurements are used to constrain the high energy, non-thermal tails of the distribution functions providing a comprehensive electron, proton, and helium spectra from less than 0.01 keV to a few MeV.

Minow, Joseph I.↗

Plutonium in Manhattan Project workers: Using autopsy data to evaluate organ content and dose estimates based on urine bioassay with implications for radiation epidemiology

Purpose Radiation dose estimates in epidemiology typically rely on intake predictions based on urine bioassay measurements. The purpose of this article is to compare the conventional dosimetric estimates for radiation epidemiology with the estimates based on additional post-mortem tissue radiochemical analysis results. Methods The comparison was performed on a unique group of 11 former Manhattan Project nuclear workers, who worked with plutonium in the 1940s, and voluntarily donated their bodies to the United States Transuranium and Uranium Registries. Results Post-mortem organ activities were predicted using different sets of urine data and compared to measured activities. Use of urinalysis data collected during the exposure periods overestimated the systemic (liver+skeleton) deposition of 239 Pu by 155±134%, while the average bias from using post-exposure urinalyses was –4±50%. Committed effective doses estimated using early urine data differed from the best estimate by, on average, 196±193%; inclusion of follow-up urine measurements in analyses decreased the mean bias to 0.6±36.3%. Cumulative absorbed doses for the liver, red marrow, bone surface, and brain were calculated for the actual commitment period. Conclusion On average, post-exposure urine bioassay results were in good agreement with post-mortem tissue analyses and were more reliable than results of urine bioassays collected during the exposure.

60 APPLIED LIFE SCIENCES↗

Radiation Limits for CBETA Halbach Magnets (CBETA machine note #036)

The radiation damage calculation proceeds via several stages to get from energy lost by the beam to the field degradation from radiation damage: • Beam energy lost → Specific radiation dose. This just divides the absorbed energy by the mass it was deposited in to convert from J to Gy=J/kg, or rad=0.01Gy. • Specific radiation dose → Magnetisation loss. This depends on the permanent magnet material grade as well as the magnetisation geometry (the “H” field). Magnetisation loss rates have been studied in the literature and this note will follow the formula. • Magnetisation loss → Field change in beam aperture. For uniform magnetisation loss, this is simply proportional (1% less magnetisation = 1% less field). For nonuniform demagnetisation, nonlinear fields errors are also introduced. As the magnetic material has mu_r ~= 1, in this note the H and M fields will be scaled by mu_0 to put them in units of Tesla, which allows easy comparison with B fields and the residual field Br.

43 PARTICLE ACCELERATORS↗

Design, Construction, and Commissioning of the RH LLW Disposal Facility at INL - 19445

The newly-commissioned Remote-Handled Low-Level Waste (RH LLW) Disposal Facility at Idaho National Laboratory (INL) provides permanent disposal capability critical for continuing INL nuclear research and Naval Reactors missions at the Idaho site. The facility mission need [critical decision (CD)- 0] was approved in 2009. Alternative selection (CD-1) was finalized in 2011. The project performance baseline (CD-2/3) was approved and design was initiated in 2014 and construction began in 2015. Construction was completed and transitioned to Materials and Fuels Complex (MFC) Operations in 2017. The facility successfully achieved readiness with authorization to begin operations (CD-4) in 2018. The $77 M line-item capital-acquisition project was completed six months ahead of the congressional commitment date and significantly under budget. This paper presents highlights of the RH LLW Disposal Facility project delivery and a summary of facility features and critical characteristics. Highlights include: - As a hazard category II nuclear facility, the project complied with United States Department of Energy (DOE) requirements for incorporation of nuclear safety into facility design and construction as identified in DOE-STD-1189 as well as 10 CFR 835 Subpart K requirements for incorporation of ALARA principles in facility design. - From an environmental compliance perspective, the facility was subject to National Environmental Policy Act requirements resulting in a Finding of No Significant Impact as determined by an Environmental Assessment. An operating disposal authorization statement from the Low-Level Waste Disposal Facility Federal Review Group (LFRG) authorizing waste disposal operations in accordance with DOE Order 435.1 was obtained. - The project was delivered using a design-build delivery method with a firm-fixed price with incentive fee contracting mechanism. The project was executed as a line-item capital-acquisition project, in full compliance with DOE Order 413.3B under INL's certified Earned Value Management System (EVMS) program. - The facility supports twenty years of waste disposal operations with five disposal vault configurations in four vault arrays supporting six different cask/canister system configurations. Three of the six cask/canister systems currently exist and three will be developed to support future operations. There are a total of 446 waste disposal vaults that will accommodate disposal of a total of 939 stainless steel radioactive waste canisters. The facility is designed to accommodate canisters with contact radiation dose rates as high as 600 Sievert/hour (60,000 Rem/hour). - The facility underwent a rigorous readiness review process in accordance with DOE Order 425.1D. Readiness activities included rigorous facility testing and shakedown activities, a management-self assessment, a contractor operational readiness review, and a DOE operational readiness review. Readiness was demonstrated for an existing cask/canister system (the MFC HFEF-5 cask). Separate readiness activities will be conducted for each cask/canister system as they are brought online for facility operations. INL's successful delivery of the project has provided waste disposal capability to ensure long-term viability of planned and current facilities and missions associated with both INL and the Naval Reactors Facility. Successful execution of the project has proven to be strategically important to future capital investments in capabilities necessary to advance INL's mission. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WE-G-BRE-03: Dose Painting by Numbers Using Targeted Gold Nanoparticles

Purpose: Homogeneous dose enhancement in tumor cells of lung cancer patients treated with conventional dose of 60–66 Gy in five fractions is limited due to increased risk of toxicity to normal structures. Dose painting by numbers (DPBN) is the prescription of a non-uniform radiation dose distribution in the tumor for each voxel based on the intensity level of that voxel obtained from the tumor image. The purpose of this study is to show that DPBN using targeted gold nanoparticles (GNPs) could enhance conventional doses in the more resistant tumor areas. Methods: Cone beam computed tomography (CBCT) images of GNPs after intratumoral injection into human tumor were taken at 0, 48, 144 and 160 hours. The dose enhancement in the tumor voxels by secondary electrons from the GNPs was calculated based on analytical microdosimetry methods. The dose enhancement factor (DEF) is the ratio of the doses to the tumor with and without the presence of GNPs. The DEF was calculated for each voxel of the images based on the GNP concentration in the tumor sub-volumes using 6-MV photon spectra obtained using Monte Carlo simulations at 5 cm depth (10×10 cm2 field). Results: The results revealed DEF values of 1.05–2.38 for GNPs concentrations of 1–30 mg/g which corresponds to 12.60 – 28.56 Gy per fraction for delivering 12 Gy per fraction homogenously to lung tumor region. Conclusion: Our preliminary results verify that DPBN could be achieved using GNPs to enhance conventional doses to high risk tumor sub-volumes. In practice, DPBN using GNPs could be achieved due to diffusion of targeted GNPs sustainably released in-situ from radiotherapy biomaterials (e.g. fiducials) coated with polymer film containing the GNPs.

60 APPLIED LIFE SCIENCES↗

Investigation of P(VDF-TrFE)/ZrO{sub 2}-MMA polymer composites applied to radiation shielding

Exposure to high radiation dose in medical diagnostic imaging procedures can lead patients to suffer tissue damaging. However, there are several studies that identify significant dose reduction with the use of radiation protective attenuators, minimizing the delivered dose in the region that covers the main beam, while preserving the diagnostic quality of the generated image. Most radiation attenuator materials are produced from shielding metal containing composites, whose efficiency is the goal of investigations around the world. In this context, polymeric materials were chosen for this investigation in order to provide light-weighted and flexible protective composites, a must in personal protective shielding. Therefore, this work is concerned to the investigation of poly(vinylidene fluoride - try-fluor-ethylene) [P(VDF-TrFE)] copolymers mixed with zirconia nanoparticles. The resulting polymer composites, prepared with 1, 2, 3, 5 and 10 at.% of ZrO{sub 2} nanoparticles, were investigated for application as protective shielding in some interventional radiology procedures. Two variety of composites were produced, one using pure ZrO{sub 2} nanoparticles and the other using sol-gel route with zirconium butoxide as the precursor for zirconium oxide nano-clusters. The P(VDFTrFE)/ ZrO2-MMA polymer composites produced by sol-gel route have provided a much better dispersion of the pure ZrO{sub 2} material into the P(VDF-TrFE) host matrix. UV-Vis and FTIR spectrometry and differential scanning calorimetry (DSC) were used to characterize the composite samples. FTIR data reveal a possible link between the MMA monomers with the P(VDF-TrFE) chain through shared C=O bonds. The radiation shielding characterization was conducted by using a 70 kV x-rays beam which is applicable, for instances, in catheter angiography. The results demonstrate that composites with 10% of ZrO{sub 2}, and only 1.0 mm thick, can attenuate 60% of the x-rays beam. The composite density was evaluated to be 2.20 g/cm{sup 3}. The results indicate that P(VDF-TrFE)/ZrO{sub 2}-MMA polymer composites have potential to be investigated as light-weighted and flexible protective shielding for application in some radiological procedures that uses low kilovoltage x-ray beams. (authors)

36 MATERIALS SCIENCE↗

Preliminary Thermal Design of Cryogenic Radiation Shielding

Cryogenic Hydrogen Radiation Shielding (CHRS) is the most mass efficient material radiation shielding strategy for human spaceflight beyond low Earth orbit (LEO). Future human space flight, mission beyond LEO could exceed one year in duration. Previous radiation studies showed that in order to protect the astronauts from space radiation with an annual allowable radiation dose less than 500 mSv, 140 kgm2 of polyethylene is necessary. For a typical crew module that is 4 meter in diameter and 8 meter in length. The mass of polyethylene radiation shielding required would be more than 17,500 kg. The same radiation study found that the required hydrogen shielding for the same allowable radiation dose is 40 kgm2, and the mass of hydrogen required would be 5, 000 kg. Cryogenic hydrogen has higher densities and can be stored in relatively small containment vessels. However, the CHRS system needs a sophisticated thermal system which prevents the cryogenic hydrogen from evaporating during the mission. This study designed a cryogenic thermal system that protects the CHRS from hydrogen evaporation for one to up to three year mission. The design also includes a ground based cooling system that can subcool and freeze liquid hydrogen. The final results show that the CHRS with its required thermal protection system is nearly half of the mass of polyethylene radiation shielding.

radiation↗