Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Overview of Materials International Space Station Experiment 7B

Materials International Space Station Experiment 7B (MISSE 7B) is the most recent in a series of experiments flown on the exterior of International Space Station for the purpose of determining the durability of materials and components in the space environment. A collaborative effort among the Department of Defense, the National Aeronautics and Space Administration, industry, and academia, MISSE 7B will be flying a number of NASA experiments designed to gain knowledge in the area of space environmental effects to mitigate risk for exploration missions. Consisting of trays called Passive Experiment Containers, the suitcase sized payload opens on hinges and allows active and passive experiments contained within to be exposed to the ram and wake or zenith and nadir directions in low Earth orbit, in essence, providing a test bed for atomic oxygen exposure, ultraviolet radiation exposure, charged particle radiation exposure, and thermal cycling. New for MISSE 7B is the ability to monitor experiments actively, with data sent back to Earth via International Space Station communications. NASA?s active and passive experiments cover a range of interest for the Agency. Materials relevant to the Constellation Program include: solar array materials, seal materials, and thermal protection system materials. Materials relevant to the Exploration Technology Development Program include: fabrics for spacesuits, materials for lunar dust mitigation, and new thermal control coatings. Sensors and components on MISSE 7B include: atomic oxygen fluence monitors, ultraviolet radiation sensors, and electro-optical components. In addition, fundamental space environmental durability science experiments are being flown to gather atomic oxygen erosion data and thin film polymer mechanical and optical property data relevant to lunar lander insulation and the James Web Space Telescope. This paper will present an overview of the NASA experiments to be flown on MISSE 7B, along with a summary of the thermal environment to be expected during the 1 yr mission scheduled for launch in 2009.

Jaworske, Donald A.↗

UAVs for Radiological Monitoring: Determining Ideal Operational Parameters From GEANT4 Simulations - 18025

Owing in no small part to the enormous advances in radiation detector technology (size, sensitivity and spectral-resolution), there has been an increased drive and requirement to accurately map both the spatial extent and magnitude of radiological contamination at the greatest possible spatial resolutions. To undertake this, a range of different methods have been devised and include the use of cars and human, but also planes (and more recently) unmanned aerial vehicles (UAVs). However, critical to the remote sensing using such UAVs in contrast to ground-based sensing, is (i) the selection of the ideal operational parameters to attain the best on-ground resolution in addition to, (ii) understanding the correct normalisation procedures and other influences on results that surveys at these reduced altitudes might present. Resulting from earlier works, through employing combined modelling and experimental data, the optimal height for a UAV survey using the more realistic 'area' radioactive source term (opposed to an infinitely-small 'point-source') is determined to be approximately 5 m - suitably maximizing cross detector counts. At greater altitudes than this, the influence of variations in neighboring topology / topography and nearby structures are observed to be negligible. However, at this and further-reduced altitudes (where optimal count-rates exists), small height-related variations are observed to result, and impact considerably on the complexity of the data normalisation. Whilst not occurring as a tool to entirely replace ground-based surveys, UAV systems are able to perform in challenging or dangerous environments, inadvisable or problematic to send humans. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of a GM tube based environmental dose rate monitor operating in the Time-To-Count mode

The events at the Fukushima Daiichi power plant in the aftermath of a natural disaster underline the importance of a large array of networked environmental monitors to cover areas around nuclear power plants. These monitors should meet a few basic criteria: have a uniform response over a wide range of gamma energies, have a uniform response over a wide range of incident angles, and have a large dynamic range. Many of these criteria are met if the probe is qualified to the international standard IEC 60532 (Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV), which specifically deals with energy response, angle of incidence, dynamic range, response time, and a number of environmental characteristics. EcoGamma is a dual GM tube environmental gamma radiation monitor designed specifically to meet the requirements of IEC 60532 and operate in the most extreme conditions. EcoGamma utilizes two energy compensated GM tubes operating with a Time-To-Count (TTC) collection algorithm. The TTC algorithm extends the lifetime and range of a GM tube significantly and allows the dual GM tube probe to achieve linearity over approximately 10 decades of gamma dose rate (from the Sv/hr range to 100 Sv/hr). In the TTC mode of operation, the GM tube is not maintained in a biased condition continuously. This is different from a traditional counting system where the GM tube is held at a constant bias continuously and the total number of strikes that the tube registers are counted. The traditional approach allows for good sensitivity, but does not lend itself to a long lifetime of the tube and is susceptible to linearity issues at high count rates. TTC on the other hand only biases the tube for short periods of time and in effect measures the time between events, which is statistically representative of the total strike rate. Since the tube is not continually biased, the life of the tube is extended and the linearity is greatly improved. Testing has been performed at Pacific Northwest National Laboratory (PNNL) in the USA and confirms compliance to IEC 60532 as well as linearity (± 10%) up to 100 Sv/hr. Furthermore, a network of EcoGamma probes may be linked through available supervisory software to provide a dose rate map of an area. This allows for real time monitoring of dose rates from one (or multiple) remote locations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a phoswich detector system for radioxenon monitoring

Abstract Measurement of radioactive xenon in the atmosphere is one of several techniques to detect nuclear weapons testing. For high sensitivity, some existing systems use beta/gamma coincidence detection to suppress background, which is very effective, but increases complexity due to separate beta and gamma detectors that require careful calibration and gain matching. In this paper, we will describe the development and evaluation of a simpler detector system, named PhosWatch, consisting of a CsI(Tl)/ BC-404 phoswich well detector, digital readout electronics, and pulse shape analysis algorithms implemented in a digital signal processor on the electronics, and compare its performance to existing multi-detector systems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Occupational Exposure to Natural Sources of Ionising Radiation in Ireland

The Radiological Protection Institute of Ireland (RPII) has recently completed a detailed evaluation of all radiation exposure pathways from sources of both natural and artificial radiation in the Irish environment. This paper presents a compilation of the occupational doses received by Irish workers exposed to natural sources of ionising radiation.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-614: Plan Averaging for Multi-Criteria Navigation of Step-And-Shoot IMRT

Purpose: Step-and-shoot IMRT is fundamentally discrete in nature, while multi-criteria optimization (MCO) is fundamentally continuous: the MCO planning consists of continuous sliding across the Pareto surface (the set of plans which represent the tradeoffs between organ-at-risk doses and target doses). In order to achieve close to real-time dose display during this sliding, it is desired that averaged plans share many of the same apertures as the pre-computed plans, since dose computation for apertures generated on-the-fly would be expensive. We propose a method to ensure that neighboring plans on a Pareto surface share many apertures. Methods: Our baseline step-and-shoot sequencing method is that of K. Engel (a method which minimizes the number of segments while guaranteeing the minimum number of monitor units), which we customize to sequence a set of Pareto optimal plans simultaneously. We also add an error tolerance to study the relationship between the number of shared apertures, the total number of apertures needed, and the quality of the fluence map re-creation. Results: We run tests for a 2D Pareto surface trading off rectum and bladder dose versus target coverage for a clinical prostate case. We find that if we enforce exact fluence map recreation, we are not able to achieve much sharing of apertures across plans. The total number of apertures for all seven beams and 4 plans without sharing is 217. With sharing and a 2% error tolerance, this number is reduced to 158 (73%). Conclusion: With the proposed method, total number of apertures can be decreased by 42% (averaging) with no increment of total MU, when an error tolerance of 5% is allowed. With this large amount of sharing, dose computations for averaged plans which occur during Pareto navigation will be much faster, leading to a real-time what-you-see-is-what-you-get Pareto navigation experience. Minghao Guo and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Background Radiation Observations Procedure

This procedure will provide guidance concerning the collection of preliminary background radiation data for the Second Line of Defense (SLD) Program. Making preliminary background radiation observations is important during initial visits where radiation portal monitors (RPMs) are being considered for installation to highlight clear problem areas of high radiation that could impact RPM performance. The information collected during initial site surveys is used to document clear problem areas and guide design discussions with the stakeholders during the visit. This information also helps to guide the conceptual design of proposed locations for RPM and secondary inspection sites. This procedure groups the processes of the preliminary background radiation observations into the following steps: 1. previsit preparations and logistics, 2. procedures, and 3. use of data.

Instrumentation Related to Nuclear Science & Techn↗

Tonopah Test Range Air Monitoring: CY2015 Meteorological, Radiological, and Airborne Particulate Observations

In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). The operation resulted in radionuclide-contaminated soils at the Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III, and at the TTR Sandia National Laboratories (SNL) Range Operations Control (ROC) center. The primary objective of the monitoring effort is to determine if winds blowing across the Clean Slate sites are transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites. Radionuclide assessment of airborne particulates in 2015 found the gross alpha and gross beta values of dust collected from the filters at the monitoring stations are consistent with background conditions. The meteorological and particle monitoring indicate that conditions for wind-borne contaminant movement exist at the Clean Slate sites and that, although the transport of radionuclide-contaminated soil by suspension has not been detected, movement by saltation is occurring.

54 ENVIRONMENTAL SCIENCES↗

INTEGRATION OF THE H3D-M400 DETECTOR AND SPOT ROBOT FOR AUTOMATED AREA SURVEY MISSIONS

Office of Nuclear Smuggling Detection and Deterrence (NSDD) is charged to identify and develop technologies to detect, disrupt, and investigate smuggling of radiological and nuclear materials •Border protection involves primary inspections using Radiation Portal Monitors (RPM), complimented with secondary and area survey inspections, usually performed manually using portable radiation detectors (PRDs) -RPM rely on fast technologies which provide quick scans of passing cargo/vehicles -Secondary inspections rely on trained, field deployed staff responsible for additional interdiction of screened cargo/vehicle putting them in potentially hazardous environment -Area survey inspections rely on trained, field deployed staff responsible for scanning and identifying presence of radiation while patrolling through a facility or public space •This project explores the use of technology which could reduce risks to field inspectors and add efficiency •The work presented here is a proof of principle of detector-robot integration to perform area survey inspections

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Continuous Monitoring and On-line Analysis of Operational Dose Rates: Tools to Further Mitigate Radiation Risks

Along with passive and active engineering and administrative controls usually implemented in radiation protection programs at different facilities, continuous monitoring and on-line analysis of data measured by the radiation detectors at the workplace and in the environment can be considered as an additional tool used to further mitigate radiation risks. Many monitoring systems on the market today allow connecting radiation area monitors into a network, and reading and accumulating data continuously in a database. The point of this presentation is to bring attention to the fact that such accumulated information can be analyzed and used in many respects to improve reliability and functionality of the monitoring and control systems. A simple time history of background readings from a radiation detector can be used to evaluate the stability of the detector performance. Data recorded during normal facility operations may serve to establish a pattern of acceptable dose rates in such detector and allow to better detect off-normal and unstable modes of the facility operation before they reach hardware trip levels. Facility operators and users may utilize such monitoring systems to optimize operations and minimize their radiological impact. Implementation and examples of use of the RADMON radiation monitoring and data analysis system at Jefferson Lab is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BLAZARS IN THE FERMI ERA: THE OVRO 40 m TELESCOPE MONITORING PROGRAM

The Large Area Telescope (LAT) aboard the Fermi Gamma-ray Space Telescope provides an unprecedented opportunity to study gamma-ray blazars. To capitalize on this opportunity, beginning in late 2007, about a year before the start of LAT science operations, we began a large-scale, fast-cadence 15 GHz radio monitoring program with the 40 m telescope at the Owens Valley Radio Observatory. This program began with the 1158 northern ({delta} > -20{sup 0}) sources from the Candidate Gamma-ray Blazar Survey and now encompasses over 1500 sources, each observed twice per week with about 4 mJy (minimum) and 3% (typical) uncertainty. Here, we describe this monitoring program and our methods, and present radio light curves from the first two years (2008 and 2009). As a first application, we combine these data with a novel measure of light curve variability amplitude, the intrinsic modulation index, through a likelihood analysis to examine the variability properties of subpopulations of our sample. We demonstrate that, with high significance (6{sigma}), gamma-ray-loud blazars detected by the LAT during its first 11 months of operation vary with almost a factor of two greater amplitude than do the gamma-ray-quiet blazars in our sample. We also find a significant (3{sigma}) difference between variability amplitude in BL Lacertae objects and flat-spectrum radio quasars (FSRQs), with the former exhibiting larger variability amplitudes. Finally, low-redshift (z < 1) FSRQs are found to vary more strongly than high-redshift FSRQs, with 3{sigma} significance. These findings represent an important step toward understanding why some blazars emit gamma-rays while others, with apparently similar properties, remain silent.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-207-14: Low Contrast Detectability (LCD) at Different Diagnostic Reference Levels for Adult Abdominal CT Procedures

Purpose Using diagnostic reference levels (DRL) to optimize CT protocols has potential to reduce radiation dose and meet regulatory requirements. However, DRL’s tend to be misconstrued as dose limits, are typically designed for specific patient populations, and are assumed to have acceptable image quality (AIQ) associated with them. To determine the image quality that is associated with established DRL’s for adult abdominal CT studies, a LCD phantom study was employed. Methods: A CT phantom (CIRS) containing three columns of 7 spherical targets, ranging from 10mm to 2.4 mm, that are 5, 10, and 20 HU below the background (HUBB) matrix was scanned with a GE HD750 64 slice scanner. The phantom was scanned at the NEXT 2006 25th CTDIvol of 12 mGy, the NCRP 172 achievable dose (AD) CTDIvol of 17 mGy and 75th CTDIvol of 25 mGy and at the ACR recommended CTDIvol of 25 mGy. It was also scanned at a CTDIvol 20% greater than the AD at 20 mGy and the ACR maximum threshold of 30 mGy. Results: At the NEXT 2006 25th percentile CTDIvol of 12 mGy, a 6.3 mm low contrast lesion was detectable in the 20 HUBB; 6.3 mm in the 10 HUBB and 10 mm in the 5 HUBB column. Increasing the CTDIvol to the NCRP 172 AD of 17 mGy, an additional 4.8 mm lesion was visualized in the 20 HUBB column. At 20 mGy, an additional 4.8 mm lesion was detectable in the 10 HUBB column. No further lesions were visible between 20 and 30 mGy. However, conspicuity of all lesions increased with each additional step up in CTDI. Conclusion: Optimizing radiation dose to achieve AIQ is a critical aspect of any dose optimization committee. Hence, judicious monitoring of radiation exposure to patients has to be balanced with diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

Global Technogenic Day- and Nightglows Detected onboard the Vernov Satellite in the Ultraviolet and Infrared Optical Spectral Ranges

The generation of transient and other optical phenomena in the Earth’s upper atmosphere under the action of electron fluxes and high- and low-frequency electromagnetic waves resulting from electromagnetic fields [1] has been studied onboard the small Vernov spacecraft (solar synchronous orbit, 98° inclination, altitude 640–830 km). On the night side at middle latitudes, the technogenic glow is shown to be observed along the preferential meridians whose distribution corresponds to the longitudes of the most powerful low-frequency radio stations [2]. The geographic distribution of this glow changes abruptly at the boundary between the day and night sides of the satellite orbit; on the day side, such meridians are not identified, while their geographic distribution in longitude is uniform. The boundaries of the geographic distribution of technogenic glow regions on the day side are unstable in latitude, their northern and southern boundaries are shifted at all latitudes from the North Pole to the South Pole. At middle and low latitudes, zones with random geographic coordinates, where the technogenic glow is completely absent, are observed in the distributions of signals along the meridians. When studying the flashes caused by discharges in the atmosphere, we showed that lightning flashes and transient luminous events at nighttime are observed mainly in equatorial regions, which coincide with zones of high thunderstorm activity. At daytime, flashes of light are recorded much more rarely, have a short duration, are observed most often in the Earth’s polar regions, including the winter periods, the power of their emission exceeds considerably the power of similar (in duration) short flashes observed at night.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Detection of Reactor Antineutrinos for Reactor Core Monitoring: an Overview

There have been new developments in the field of applied neutrino physics during the last decade. The International Atomic Energy Agency (IAEA) has expressed interest in the potentialities of antineutrino detection as a new tool for reactor monitoring and has created an ad hoc Working Group in late 2010 to follow the associated research and development. Several research projects are ongoing around the world to build antineutrino detectors dedicated to reactor monitoring, to search for and develop innovative detection techniques, or to simulate and study the characteristics of the antineutrino emission of actual and innovative nuclear reactor designs. We give, in these proceedings, an overview of the relevant properties of antineutrinos, the possibilities of and limitations on their detection, and the status of the development of a variety of compact antineutrino detectors for reactor monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MO-D-213-01: Workflow Monitoring for a High Volume Radiation Oncology Center

Purpose: Implement a center wide communication system that increases interdepartmental transparency and accountability while decreasing redundant work and treatment delays by actively monitoring treatment planning workflow. Methods: Intake Management System (IMS), a program developed by ProCure Treatment Centers Inc., is a multi-function database that stores treatment planning process information. It was devised to work with the oncology information system (Mosaiq) to streamline interdepartmental workflow.Each step in the treatment planning process is visually represented and timelines for completion of individual tasks are established within the software. The currently active step of each patient’s planning process is highlighted either red or green according to whether the initially allocated amount of time has passed for the given process. This information is displayed as a Treatment Planning Process Monitor (TPPM), which is shown on screens in the relevant departments throughout the center. This display also includes the individuals who are responsible for each task.IMS is driven by Mosaiq’s quality checklist (QCL) functionality. Each step in the workflow is initiated by a Mosaiq user sending the responsible party a QCL assignment. IMS is connected to Mosaiq and the sending or completing of a QCL updates the associated field in the TPPM to the appropriate status. Results: Approximately one patient a week is identified during the workflow process as needing to have his/her treatment start date modified or resources re-allocated to address the most urgent cases. Being able to identify a realistic timeline for planning each patient and having multiple departments communicate their limitations and time constraints allows for quality plans to be developed and implemented without overburdening any one department. Conclusion: Monitoring the progression of the treatment planning process has increased transparency between departments, which enables efficient communication. Having built-in timelines allows easy prioritization of tasks and resources and facilitates effective time management.

60 APPLIED LIFE SCIENCES↗

Management of the baseline shift using a new and simple method for respiratory-gated radiation therapy: Detectability and effectiveness of a flexible monitoring system

Purpose: In respiratory-gated radiation therapy, a baseline shift decreases the accuracy of target coverage and organs at risk (OAR) sparing. The effectiveness of audio-feedback and audio-visual feedback in correcting the baseline shift in the breathing pattern of the patient has been demonstrated previously. However, the baseline shift derived from the intrafraction motion of the patient's body cannot be corrected by these methods. In the present study, the authors designed and developed a simple and flexible system. Methods: The system consisted of a web camera and a computer running our in-house software. The in-house software was adapted to template matching and also to no preimage processing. The system was capable of monitoring the baseline shift in the intrafraction motion of the patient's body. Another marker box was used to monitor the baseline shift due to the flexible setups required of a marker box for gated signals. The system accuracy was evaluated by employing a respiratory motion phantom and was found to be within AAPM Task Group 142 tolerance (positional accuracy <2 mm and temporal accuracy <100 ms) for respiratory-gated radiation therapy. Additionally, the effectiveness of this flexible and independent system in gated treatment was investigated in healthy volunteers, in terms of the results from the differences in the baseline shift detectable between the marker positions, which the authors evaluated statistically. Results: The movement of the marker on the sternum [1.599 {+-} 0.622 mm (1 SD)] was substantially decreased as compared with the abdomen [6.547 {+-} 0.962 mm (1 SD)]. Additionally, in all of the volunteers, the baseline shifts for the sternum [-0.136 {+-} 0.868 (2 SD)] were in better agreement with the nominal baseline shifts than was the case for the abdomen [-0.722 {+-} 1.56 mm (2 SD)]. The baseline shifts could be accurately measured and detected using the monitoring system, which could acquire the movement of the marker on the sternum. The baseline shift-monitoring system with the displacement-based methods for highly accurate respiratory-gated treatments should be used to make most of the displacement-based gating methods. Conclusions: The advent of intensity modulated radiation therapy and volumetric modulated radiation therapy facilitates margin reduction for the planning target volumes and the OARs, but highly accurate irradiation is needed to achieve target coverage and OAR sparing with a small margin. The baseline shifts can affect treatment not only with the respiratory gating system but also without the system. Our system can manage the baseline shift and also enables treatment irradiation to be undertaken with high accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association Between Pulmonary Uptake of Fluorodeoxyglucose Detected by Positron Emission Tomography Scanning After Radiation Therapy for Non-Small-Cell Lung Cancer and Radiation Pneumonitis

Purpose: To study the relationship between fluorodeoxyglucose (FDG) uptake in pulmonary tissue after radical radiation therapy (RT) and the presence and severity of radiation pneumonitis. Methods and Materials: In 88 consecutive patients, {sup 18}F-FDG-positron emission tomography was performed at a median of 70 days after completion of RT. Patients received 60 Gy in 30 fractions, and all but 15 had concurrent platinum-based chemotherapy. RT-induced pulmonary inflammatory changes occurring within the radiation treatment volume were scored, using a visual (0 to 3) radiotoxicity grading scale, by an observer blinded to the presence or absence of clinical radiation pneumonitis. Radiation pneumonitis was retrospectively graded using the Radiation Therapy Oncology Group (RTOG) scale by an observer blinded to the PET radiotoxicity score. Results: There was a significant association between the worst RTOG pneumonitis grade occurring at any time after RT and the positron emission tomograph (PET) radiotoxicity grade (one-sided p = 0.033). The worst RTOG pneumonitis grade occurring after the PET scan was also associated with the PET radiotoxicity grade (one-sided p = 0.035). For every one-level increase in the PET toxicity scale, the risk of a higher RTOG radiation pneumonitis score increased by approximately 40%. The PET radiotoxicity score showed no significant correlation with the duration of radiation pneumonitis. Conclusions: The intensity of FDG uptake in pulmonary tissue after RT determined using a simple visual scoring system showed significant correlation with the presence and severity of radiation pneumonitis. {sup 18}F-FDG-PET may be useful in the prediction, diagnosis and therapeutic monitoring of radiation pneumonitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗