Search NASA⌕ Search

SEARCH · Search NASA

Results for “SOLID STATE DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

604 records · Page 34

Optical Sensors for Biomolecules Using Nanoporous Sol-Gel Materials

An important consideration for space missions to Mars is the ability to detect biosignatures. Solid-state sensing elements for optical detection of biological entities are possible using sol-gel based biologically active materials. We have used these materials as optical sensing elements in a variety of bioassays, including immunoassays and enzyme assays. By immobilizing an appropriate biomolecule in the sol-gel sensing element, we have successfully detected analytes such as amino acids and hormones. In the case of the amino acid glutamate, the enzyme glutamate dehydrogenase was the immobilized molecule, whereas in the case of the hormone cortisol, an anti-cortisol antibody was immobilized in the sensing element. In this previous work with immobilized enzymes and antibodies, excellent sensitivity and specificity were demonstrated in a variety of formats including bulk materials, thin films and fibers. We believe that the sol-gel approach is an attractive platform for bioastronautics sensing applications because of the ability to detect a wide range of entities such as amino acids, fatty acids, hopanes, porphyrins, etc. The sol-gel approach produces an optically transparent 3D silica matrix that forms around the biomolecule of interest, thus stabilizing its structure and functionality while allowing for optical detection. This encapsulation process protects the biomolecule and leads to a more "rugged" sensor. The nanoporous structure of the sol-gel matrix allows diffusion of small target molecules but keeps larger, biomolecules immobilized in the pores. We are currently developing these biologically active sol-gel materials into small portable devices for on-orbit cortisol detection

Fang, Jonathan↗

Miniaturization of Planar Horn Motors

There is a great need for compact, efficient motors for driving various mechanisms including robots or mobility platforms. A study is currently underway to develop a new type of piezoelectric actuators with significantly more strength, low mass, small footprint, and efficiency. The actuators/motors utilize piezoelectric actuated horns which have a very high power density and high electromechanical conversion efficiency. The horns are fabricated using our recently developed novel pre-stress flexures that make them thermally stable and increases their coupling efficiency. The monolithic design and integrated flexures that pre-stresses the piezoelectric stack eliminates the use of stress bolt. This design allows embedding solid-state motors and actuators in any structure so that the only macroscopically moving parts are the rotor or the linear translator. The developed actuator uses a stack/horn actuation and has a Barth motor configuration, which potentially generates very large torque and speeds that do not require gearing. Finite element modeling and design tools were investigated to determine the requirements and operation parameters and the results were used to design and fabricate a motor. This new design offers a highly promising actuation mechanism that can potentially be miniaturized and integrated into systems and structures. It can be configured in many shapes to operate as multi-degrees of freedom and multi-dimensional motors/actuators including unidirectional, bidirectional, 2D and 3D. In this manuscript, we are reporting the experimental measurements from a bench top design and the results from the efforts to miniaturize the design using 2x2x2 mm piezoelectric stacks integrated into thin plates that are of the order of3 x 3x 0.2 cm.

horn actuation↗

Supercritical Water Oxidation (SCWO) Trade Study and 2021 Final Report

SCWO is a promising technology whose main benefits is that it is capable of completely mineralizing organic compounds in wastewater and separating inorganic salts. This means that SCWO can theoretically function as a single step water treatment system. It performs the functions of both the primary treatment system and the secondary brine drying function to achieve near 100% water recovery. It can also handle solids so no pretreatment of the feed is required. A preliminary trade study indicates that SCWO could be competitive with the ISS state of the art if its power consumption could be reduced. Thermal and mechanical energy recovery system exist that could reduce SCWO energy consumption to a level that is competitive with the state of the art. In addition, increasing the feed wastewaters organic content by including other wastes, such as feces, could produce a reactor that is thermally self-sustaining. There are 5 different types of SCWO reactors. They are; tubular, tank, impingement, transpiring wall reactors (TWR) and super critical water mixing (SCWM) reactors. Of these the best suited for NASA missions are the impingement and SCWM reactors. The impingement reactor is best suited for near term missions because it can treat the low organic content wastewaters such as are expected for initial Lunar and Mars missions and has the ability to remove precipitated inorganic solids. The SCWM reactor is best suited for longer duration CELSS type missions where high organic content wastewater is available and will resolve solids fouling and corrosion issues. In addition, these two reactors have a long NASA heritage and have been developed specifically for space flight application. Tubular reactors suffer from plugging issues which is a safety concern. Tank reactors will increase in size inversely with gravity, which will trade poorly in Lunar and Mars environments where gravity is reduced. TWR reactors require high organic content wastewater feed and the SCWM reactor is an optimized version of the TWR for NASA applications. It is recommended that in FY 2022 NASA continue to fully evaluate the ability of SCWO to produce potable water and remove inorganics as a solid byproduct. This should be done using the impingement reactor for near term missions and SCWM for longer duration missions. NASA should also develop optimized recuperative heat exchangers and pressure recovery devices to reduce power consumption and investigate inclusion of feces and other organic wastes into the wastewater model to increase its organic content and further reduce thermal energy requirements.

Supercritical Water Oxidation↗

Pulse Shaped 8-PSK Bandwidth Efficiency and Spectral Spike Elimination

The most bandwidth-efficient communication methods are imperative to cope with the congested frequency bands. Pulse shaping methods have excellent effects on narrowing bandwidth and increasing band utilization. The position of the baseband filters for the pulse shaping is crucial. Post-modulation pulse shaping (a low pass filter is located after the modulator) can change signals from constant envelope to non-constant envelope, and non-constant envelope signals through non-linear device (a SSPA or TWT) can further spread the power spectra. Pre-modulation pulse shaping (a filter is located before the modulator) will have constant envelope. These two pulse shaping methods have different effects on narrowing the bandwidth and producing bit errors. This report studied the effect of various pre-modulation pulse shaping filters with respect to bandwidth, spectral spikes and bit error rate. A pre-modulation pulse shaped 8-ary Phase Shift Keying (8PSK) modulation was used throughout the simulations. In addition to traditional pulse shaping filters, such as Bessel, Butterworth and Square Root Raised Cosine (SRRC), other kinds of filters or pulse waveforms were also studied in the pre-modulation pulse shaping method. Simulations were conducted by using the Signal Processing Worksystem (SPW) software package on HP workstations which simulated the power spectral density of pulse shaped 8-PSK signals, end to end system performance and bit error rates (BERS) as a function of Eb/No using pulse shaping in an AWGN channel. These results are compared with the post-modulation pulse shaped 8-PSK results. The simulations indicate traditional pulse shaping filters used in pre-modulation pulse shaping may produce narrower bandwidth, but with worse BER than those in post-modulation pulse shaping. Theory and simulations show pre- modulation pulse shaping could also produce discrete line power spectra (spikes) at regular frequency intervals. These spikes may cause interference with adjacent channel and reduce power efficiency. Some particular pulses (filters), such as trapezoid and pulses with different transits (such as weighted raised cosine transit) were found to reduce bandwidth and not generate spectral spikes. Although a solid state power amplifier (SSPA) was simulated in the non-linear (saturation) region, output power spectra did not spread due to the constant envelope 8-PSK signals.

Tao, Jian-Ping↗

TPSAS-NF1676L-32920-DND

In June 2019, a full-scale crash test of a Fokker F28 Fellowship aircraft will be conducted at NASA Langley Research Center?s Landing and Impact Research (LandIR) Facility. The F28 is a high-performance twin-turbo fan narrow-body aircraft with seating in a 3+2 configuration. The MK4000 variant, used in this test, is capable of carrying up to 85 passengers on medium range routes. The F28 was first type certified by the Federal Aviation Administration (FAA) in 1969 and now the majority of the F28 fleet has retired from service in the United States. In 2016, the FAA and NASA Langley Research Center (LaRC) signed an interagency agreement for conducting a research program to obtain test data that will support the development of airframe level crash requirements for transport category airplanes [1]. The objectives of the full-scale crash test can be divided into six categories: (1) To compare and contrast responses in identical aircraft undergoing vertical only to combined vertical and horizontal loading conditions, (2) To examine the effects of horizontal loading on aircraft structure during a crash event, (3) To generate data for the use in calibration of computer modelling efforts, (4) To generate data from onboard Anthropomorphic Test Devices (ATDs) for the evaluation of injury, (5) To obtain data from experimental seats, and (6) To obtain data from new and novel ATD designs including Warrior Injury Assessment MANikin (WIAMan) [2], Test device for Human Occupant Response (THOR), and other newly developed child ATDs. The focus of this presentation will be to document finite element model development of the full-scale F28 aircraft and to present preliminary test-analysis predictions. NASA obtained the full-scale F28 aircraft, plus three fuselage sections and two sets of wings with funding through the NASA Aviation Safety Program in 1998. In addition to the hardware, NASA purchased a full NASTRAN model of the airframe that had been developed by the Dutch manufacturer, Fokker. Beginning in 2016, the NASTRAN model was converted to LS-DYNA? [4, 5] format and modified by combining parts, adding missing parts of internal structure, and including ballast for loading weights, etc. It contains: 89,223 nodes; 24,065 beam elements; 55,404 shell elements; 29,044 solid elements; 740 parts; 80 material definitions; and, 46 Constrained Nodal Rigid Bodies (CNRBs). The aircraft model will be executed in LSDYNA to simulate the test article impact onto a 2-ft.-high bed of soil under combined velocity conditions of 70-ft/s forward and 30-ft/s vertical velocity. Pre-test simulation predictions will be generated and correlated with test data.

Karen E Jackson↗

Development of a Cold-Walled Molten Regolith Electrolysis Reactor for Lunar Oxygen Production

On the lunar surface, production of commodi-ties to support human presence, such as water, food and oxygen, and sustain the growth of a per-manent outpostwill likely require the use oflocal resources. The moon is covered almost entirely withfragmented oxide minerals known as regolithhundreds of meter thick.As a resource, it is rich in oxygen (> 42 wt.%) bound in a solid state with a variety of metals. The molten regolith electrolysis (MRE)reactor is a promising technology for the production of gaseous oxygen from the lunar reg-olithin a simple, single-stepreaction that requires minimalconsumable materials, produces oxygen and metals with high electrical efficiency and high yields from any regolithcomposition.This process involvesmelting regolith to~1600°C then electro-lyzing the molten pool to separate metal and oxy-gen ions that are then collected as liquid metal and gaseous oxygen at the respective electrodes. Lab-scale demonstrations of the MRE technology have previously reliedon external heating sources to bring the entirety of the reactor up to the operating temperaturewhich creates corrosive interfaces be-tween the molten regolith and the containment ma-terial in the reactor, limiting the overall lifespan of a reactor[1]. The Gaseous Lunar Oxygen from Regolith Electrolysis (GaLORE) project is focused on the development of a “cold-walled” or “Joule-heated” reactor design in which an internal heating source is used to selectively melt a pool of regolith between the electrodes of the reactor, leaving a shell of solidified regolith between the molten pool and the containment vessel of the reactor. This next generation reactor concept has been under development as molten oxide electrolysis (MOE) by MIT and Boston Metal for the production of iron from pure ores for terrestrial application [2]. The GaLORE project in engaged in early development of the technology for use with varying lunar regolith compositionsin the lunar environment. Thermal modelling of a proposed cold-walledreac-tor design were used as a scaffold to develop pa-rameters for a feasible reactor shape and size as well as target energy consumption[3]. The current development effort for the cold-walled reactor de-sign will be presented as a trade study of the most promising techniques for melting regolithwithin the constraints imposed by the lunar environment.Heater devices are designed to accommodate lim-ited electrical power availabilityon the moon, a wide range of regolith compositions that may be seen on the moon, limited metals available for re-placing consumed parts,and the low thermal con-ductivity of granular regolith in vacuum.Heater de-vices will be down-selectedbased on performance measurements within the above operationalcon-straints,and selected devices will be integrated into a reactor with electrodes to begin producing oxygen. [1]Sibille,L.,Sadoway, D.R.,Sirk, A., Tripathy,P.,Melendez, O., Standish, E., Dominguez, J. A., Stefanescu, D.M.,Curreri, P.A., Poizeau,S.,2009. “Recent Advancesin Scale-up Development of Molten Regolith Electrolysis for Oxygen Production in support of a Lunar Base.”AIAA 2009-659, 47th AIAA Aerospace Sciences Meeting, 5 -8 January 2009, Orlando, FL. [2] Boston Metal, https://www.boston-metal.com/moe-technology/#moe-process[3]Schreiner, S.S.,Sibille, L., Dominguez, J.A., Hoffman, J.A., 2016. "A parametric sizing model for Molten Regolith Electrolysis reactors to pro-duce oxygen on the Moon." Advances in Space Research 57.,7,1585-1603.

K D Grossman↗

Li-Ion Cells Employing Electrolytes With Methyl Propionate and Ethyl Butyrate Co-Solvents

Future NASA missions aimed at exploring Mars and the outer planets require rechargeable batteries that can operate at low temperatures to satisfy the requirements of such applications as landers, rovers, and penetrators. A number of terrestrial applications, such as hybrid electric vehicles (HEVs) and electric vehicles (EVs) also require energy storage devices that can operate over a wide temperature range (i.e., -40 to +70 C), while still providing high power capability and long life. Currently, the state-of-the-art lithium-ion system has been demonstrated to operate over a wide range of temperatures (-30 to +40 C); however, the rate capability at the lower temperatures is very poor. These limitations at very low temperatures are due to poor electrolyte conductivity, poor lithium intercalation kinetics over the electrode surface layers, and poor ionic diffusion in the electrode bulk. Two wide-operating-temperature-range electrolytes have been developed based on advances involving lithium hexafluorophosphate-based solutions in carbonate and carbonate + ester solvent blends, which have been further optimized in the context of the technology and targeted applications. The approaches employed include further optimization of electrolytes containing methyl propionate (MP) and ethyl butyrate (EB), which are effective co-solvents, to widen the operating temperature range beyond the baseline systems. Attention was focused on further optimizing ester-based electrolyte formulations that have exhibited the best performance at temperatures ranging from -60 to +60 C, with an emphasis upon improving the rate capability at -20 to -40 C. This was accomplished by increasing electrolyte salt concentration to 1.20M and increasing the ester content to 60 percent by volume to increase the ionic conductivity at low temperatures. Two JPL-developed electrolytes 1.20M LiPF6 in EC+EMC+MP (20:20:60 v/v %) and 1.20M LiPF6 in EC+EMC+EB (20:20:60 v/v %) operate effectively over a wide temperature range in MCMB-LiNiCoAlO2 and Li4Ti5O12-LiNi-CoAlO2 prototype cells. These electrolytes have enabled high rate performance at low temperature (i.e., up to 2.0C rates at -50 C and 5.0C rates at -40 C), and good cycling performance over a wide temperature range (i.e., from -40 to +70 C). Current efforts are focused upon improving the high temperature resilience of the methyl propionatebased system through the use of electrolyte additives, which are envisioned to improve the nature of the solid electrolyte interphase (SEI) layers.

Smart, Marshall C.↗

Variable Depth Bragg Peak Method for Single Event Effects Testing

Traditionally, accelerator SEE testing is accomplished by removing the tops of packages so that the IC chips are accessible to heavy ions. However, ICs in some advanced packages cannot be de-lidded so a different approach is used that involves grinding and/or chemically etching away part of the package and the chip from the back side. The parts are then tested from the back side with ions having sufficient range to reach the sensitive volume. More recently, the entire silicon substrate in an SOI/SRAM was removed, making it possible to use low-energy ions with shorter ranges. Where removal of part of the package is not possible, facilities at Michigan State, NASA Space Radiation Laboratory, GANIL (France) and GSI (Germany) offer high-energy heavy ions with long ranges so that the ions can reach the devices' sensitive volumes without much change in the LET. Unfortunately, a run will typically involve only one ion species having a single energy and LET due to the long time it takes to tune a new energy. The Variable Depth Bragg Peak (VDBP) method is similar to the above method in that it involves the use of high-energy heavy ions that are able to pass through the packaging material and reach the device, obviating the need to remove the package. However, the method provides a broad range of LETs from a single ion by inserting degraders in the beam that modify the ion energy and, therefore, the LET. The crux of the method involves establishing a fiduciary point for degrader thickness, i.e., where the Bragg peak is located precisely at the sensitive volume in the device, for which the measured SEU cross-section and the ion LET are both also maxima and can be calculated using a Monte-Carlo program, TRIM. Once the fiduciary point has been established, calibrated high density polyethylene (HDPE) degraders are inserted into or removed from the beam to vary the ion LET at the device in a known manner. After each change of degrader thickness, the SEU cross-section is measured and the corresponding LET calculated from the change in degrader thickness. That information is used to generate a plot of cross-section as a function of ion LET. The advantages of this approach are that the part does not have to be de-lidded and a broad range of LETs is available from a single heavy ion without having to go to non-normal angles of incidence to change the "effective" LET. As we will show, it is possible to obtain an entire curve of cross-section versus LET using just two or three ions. Fig. 1 shows curves of cross-section vs LET for a Freescale 4 Mbit SOI/SRAM measured at the 88" Cyclotron at Berkeley and at NSRL. The open symbols are the data obtained from Berkeley for top-side and back-side irradiation. The solid data points are for the data obtained at NSRL using a device for which the package was intact. The data are for Iron and Gold and cover a range of LETs from 4 MeV.cm2/mg to 84 MeV.cm2/mg. The agreement between the data obtained from Berkeley and from NSRL is excellent, demonstrating that the VDBP method is capable of providing accurate values of cross-section versus LET, at least for the 4 Mbit SRAM. Details of the technique will be included in the final presentation.

Buchner, S.↗

Rational Design of Nanoplasmonic Array Geometries for Biosensing

Background: Molecular diagnostics provide early and accurate diagnosis, which is essential for the prevention and treatment of infectious as well as chronic diseases. These tests are designed to detect disease-specific bioanalytes such as nucleic acid (DNA or RNA) or protein (antigens, antibodies) biomarkers. In the context of infectious disease diagnosis, nucleic acid-based detection methods are known to provide more specific and sensitive results. Here, the presence of a unique sequence belonging to the pathogenic genomic material is targeted to identify species, organism, genera and/or antimicrobial resistant gene markers. The majority of the common nucleic acid based diagnostic techniques require amplification (polymerase chain reaction, isothermal amplification etc.) of the pathogenic genetic material prior to detection impacting diagnostic speed, complexity, and cost thereby limiting ease of use. Thus, the development of simplified nucleic acid-based diagnostics that can be even used in resource-poor settings may hugely benefit patients across the globe. Nanopath is a molecular diagnostics company utilizing a solid-state nanosensor to enable sequence-specific detection of target nucleic acids without the need of amplification. These nanostructures enable ultra-sensitive biomarker detection using geometric, feature-dependent properties highly dependent on the local dielectric environment, allowing them to be sensitive to low concentration binding events. This paper describes an application of this approach to provide highly relevant clinical information within a single doctor’s office visit. Intro: The Nanopath team is in collaboration with NASA (National Aeronautics and Space Administration) and NIST (National Institute of Standards and Technology) to push the bounds of the fundamental physics associated with their biosensing platform. The ability of metals to support electromagnetic surface waves gives rise to surface plasmons when optically illuminated. This property, and its strong sensitivity to changes in the local refractive index, allows for the use of metal nanoparticles as ultra-sensitive transducers. In prior work by members of this team, ensembles of randomly oriented nanoparticles (i.e., colloidal nanorods dispersed on chip) were employed for sequence-specific nucleic acid sensing (1-3). While these particle sensors have the advantage of rapid fabrication, they suffer from low sensitivity and quality factor due to the random particle dispersity. In contrast, in this study we employ ordered array nanoparticle ensembles which can be used to improve sensor sensitivity and figure-of-merit. Study Methods Overview: In this talk, we detail the results of sensing experiments and computational simulations to outline a rational design of the structure of these plasmonic nanoparticle arrays for biomolecular sensing. Through simulation and experiment, we iteratively tailor nanostructure dimension to provide high quality signal and large resonance shifts upon modeled nucleic acid binding. In particular, full-wave electromagnetic simulations were conducted using Lumerical photonic simulation software in which periodic boundary conditions were applied in the x- and y- dimensions for each of the nanoplasmonic sensor geometries. To simulate the resonance response to changes in the bulk solution in contact with the sensor surface, the refractive index of the surrounding media was changed appropriately. Nucleic acid hybridization events were modeled using either using spherical structures approximating the relevant radius of genomic material as estimated by polymer models, or as conformal layers with the known refractive indices for nucleic acids. On the basis of initial simulations, nanosensors were fabricated using traditional electron-beam lithography protocols at NIST. To evaluate consensus between simulations and experiments, bulk sensing experiments were carried out in which the resonance peaks were obtained by submerging the sensors in refractive index standards. Key nanosensor characteristics including resonance peak locations, resonance peak shifts as a function of refractive index, and figure of merit (FOM) of extinction curves were examined between the experimental and simulation results prior to proceeding with simulations on additional geometries and more complex solution conditions, and further device fabrication. This iterative process is repeated toward a rational design of nanoplasmonic array geometries for biosensing optimizing response for targeted disease detection. In summary, this study puts forth a methodology for rational design and characterization of regularly spaced nanoparticle arrays for optics-based biosensing. The results of this study will allow for more informed design of nanostructure geometries towards sequence-specific nucleic acid detection. These improved designs have the potential to improve clinical sensitivity and limit-of-detection across disease indication.

sensor↗

Hardware in the Loop Testing of an Iodine-Fed Hall Thruster

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload,1 providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm cu and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high delta v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ρIsp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature ( less than100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp -6) torr at -75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. In the present paper, we describe testing performed using an iodine-fed 200 W Hall thruster mounted to a thrust stand and operated in conjunction with MSFCs Small Projects Rapid Integration and Test Environment (SPRITE) Portable Hardware In the Loop (PHIL) hardware. This work is performed in support of the iodine satellite (iSAT) project, which aims to fly a 200-W iodine-fed thruster on a 12-U CubeSat. The SPRITE PHIL hardware allows a given vehicle to do a checkout of its avionics algorithm by allowing it to monitor and feed data to simulated sensors and effectors in a digital environment. These data are then used to determine the attitude of the vehicle and a separate computer is used to interpret the data set and visualize it using a 3D graphical interface. The PHIL hardware allows the testing of the vehicles bus by providing 'real' hardware interfaces (in the case of this test a real RS422 bus) and specific components can be modeled to show their interactions with the avionics algorithm (e.g. a thruster model). For the iSAT project the PHIL is used to visualize the operating cycle of the thruster and the subsequent effect this thrusting has on the attitude of the satellite over a given period of time. The test is controlled using software running on an Andrews Space Cortex 160 flight computer. This computer is the current baseline for a full iSAT mission. While the test could be conducted with a lab computer and software, the team chose to exercise the propulsion system with a representative CubeSat-class computer. For purposes of this test, the "flight" software monitored the propulsion and PPU systems, controlled operation of the thruster, and provided thruster state data to the PHIL simulation. Commands to operate the thruster were initiated from an operator's workstation outside the vacuum chamber and passed through the Cortex 160 to exercise portions of the flight avionics. Two custom-designed pieces of electronics hardware have been designed to operate the propellant feed system. One piece of hardware is an auxiliary board that controls a latch valve, proportional flow control valves (PFCVs) and valve heaters as well as measuring pressures, temperatures and PFCV feedback voltage. An onboard FPGA provides a serial link for issuing commands and manages all lower level input-output functions. The other piece of hardware is a power distribution board, which accepts a standard bus voltage input and converts this voltage into all the different current-voltage types required to operate the auxiliary board. These electronics boards are located in the vacuum chamber near the thruster, exposing this hardware to both the vacuum and plasma environments they would encounter during a mission, with these components communicating to the flight computer through an RS-422 interface. The auxiliary board FPGA provides a 28V MOSFET switch circuit with a 20ms pulse to open or close the iodine propellant feed system latch valve. The FPGA provides a pulse width modulation (PWM) signal to a DC/DC boost converter to produce the 12-120V needed for control of the proportional flow control valve. There are eight MOSFET-switched heating circuits in the system. Heaters are 28V and located in the latch valve, PFCV, propellant tank and propellant feed lines. Both the latch valve and PFCV have thermistors built into them for temperature monitoring. There are also seven resistance temperature device (RTD) circuits on the auxiliary board that can be used to measure the propellant tank and feedline temperatures. The signals are conditioned and sent to an analog to digital converter (ADC), which is directly commanded and controlled by the FPGA.

Polzin, Kurt A.↗