Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPALLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Mechanical Reliability and Life Prediction of Coated Metallic Interconnects within Solid Oxide Fuel Cells

Metallic cell interconnects (IC) made of ferritic stainless steels, i.e., iron-based alloys, have been increasingly favored in the recent development of planar solid oxide fuel cells (SOFCs) because of their advantages in excellent imperviousness, low electrical resistance, ease in fabrication, and cost effectiveness [1]. Typical SOFC operating conditions inevitably lead to the formation of oxide scales on the surface of ferritic stainless steel, which could cause delamination, buckling, and spallation resulting from the mismatch of the coefficient of thermal expansion and eventually reduce the lifetime of the interconnect components. Various protective coating techniques have been applied to alleviate these drawbacks [2]. In the present work, a fracture-mechanics-based quantitative modeling framework has been established to predict the mechanical reliability and lifetime of the spinel-coated, surface-modified specimens under an isothermal cooling cycle. Analytical solutions have been formulated to evaluate the scale/substrate interfacial strength and determine the critical oxide thickness in terms of a variety of design factors, such as coating thickness, material properties, and uncertainties. The findings then are correlated with the experimentally measured oxide scale growth kinetics to quantify the predicted lifetime of the metallic interconnects.

Solid oxide fuel cell (SOFC), Ferritic stainless s↗

Laser lift-off scribing of the CZTSe thin-film solar cells at different pulse durations

Here, the transition to fully sized solar modules requires additional three-step laser structuring processes to preserve small-scale cell efficiencies over the large areas. The adjacent cell isolation (the P3 scribe) was found to be the most sensitive process in the case of laser induced damage. The laser induced layer lift-off mechanism seems to be a very attractive process for the P3 patterning, since almost all the laser affected material is removed by mechanical spallation. However, a laser induced layer spallation behavior together with scribe electrical validation under the different laser pulse durations was not investigated extensively in the past. Therefore, we report our novel results on the P2 and P3 laser lift-off processing of the Cu 2 ZnSn(S, Se 4 ) (CZTSe) thin-film solar cells covering the pulse duration range from 300 fs to 60 ps. Shorter sub-ps pulses enabled us to process smaller P2 and P3 craters, although the lift-off threshold fluences were higher compared to the longer ps pulses. In the case of the layer lift-off, the laser radiation had to penetrate through the layer stack down to the CZTSe/Mo interface. At shorter sub-ps pulses, the nonlinear effects triggered absorption of the laser radiation in the bulk of the material, resulting in increased damage of the CZTSe layer. The Raman measurements confirmed the CZTSe surface stoichiometry changes for shorter pulses. Furthermore, shorter pulses induced higher electrical conductivity of a scribe, resulting in lower photo-electrical efficiency during the mini-module simulation. In the case of the P3 lift-off scribing, the 10 ps pulses were more favorable than shorter femtosecond pulses.

14 SOLAR ENERGY↗

Early-stage uranium-hydrogen corrosion kinetics and mechanism

Research into the early-stage uranium-hydrogen degradation mechanism lacks unified interpretation and understanding due to inadequate temporal and spatial characterization resolution required to unify reaction observations. In this study, white-light interferometry was adapted to characterize the uranium-hydrogen reaction at a temperature of 50 °C and hydrogen pressure of 13.8 kPa. The uranium surface remained unchanged for 62 min during the hydride induction period before the first hydride blister appeared. This blister was monitored from induction through critical spallation and UH₃ powder release during rapid surface hydriding. The critical spallation dimensions measured for height, diameter, area, and perimeter of the first blister were 1.79 µm, 17.58 µm, 187.7 µm 2 and 59.79 µm. Hydriding growth kinetics were assessed by tracking the first hydride site over the reaction time. Analysis shows that the spall-front velocity of the hydride was changing at a rate of 0.91 µm/min which compares favorably with legacy Sievert’s experiments in literature. Total percentage of the surface area hydrided after 242 min was 42.7%, and post-characterization of the UH 3 powders shows both α-UH 3 and β-UH 3 . This work highlights the strength of characterizing the early-stage uranium-hydrogen reaction using white-light interferometry, but more importantly, unifying the understanding and mechanism of the uranium-hydrogen reaction kinetics.

Materials science↗

Sample changers for direct geometry neutron chopper spectrometers

The advent of higher flux neutron sources has made the use of sample changers appropriate across the instrument suites at neutron scattering facilities. We examine the efficiency, design, and operation of two sample changers used at the thermal chopper spectrometers at the Spallation Neutron Source. We also present case studies of sample holders designed to accommodate multiple single crystal or powder samples for the Cold Neutron Chopper Spectrometer at the Spallation Neutron Source. [This manuscript has been authored by UT-Battelle, LLC under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan).]

Stone, Matthew B. [Oak Ridge National Laboratory (↗

Extracting source parameters from beam monitors on a chopper spectrometer

The intensity distributions of beam monitors in direct-geometry time-of-flight neutron spectrometers provide important information about the instrument resolution. For short-pulse spallation neutron sources in particular, the asymmetry of the source pulse may be extracted and compared to Monte Carlo source simulations. An explicit formula using a Gaussian-convolved Ikeda-Carpenter distribution is given and compared to data from the ARCS instrument at the Spallation Neutron Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNS Proton Beam Window Disposal

In order to support the disposal of the proton beam window assembly of the Spallation Neutron Source beamline to the target station, waste classification analyses are performed. The window has a limited life-time due to radiation-induced material damage. Here, analyses include calculation of the radionuclide inventory and shielding analyses for the transport package/container to ensure that the container is compliant with the transportation and waste management regulations. In order to automate this procedure and minimize manual work a script in Perl language was written.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IBIS: An inverse geometry Brillouin inelastic neutron spectrometer for the SNS

The high power target station at the Spallation Neutron Source (SNS) currently has about 20 completed neutron scattering instruments. With a broad coverage of the momentum transfer (Q)-energy (E) space, these instruments serve an extensive user community. In an effort to further expand the scientific capabilities of the SNS instrument suites, we propose a low background, inverse geometry Brillouin inelastic spectrometer for the SNS which will expand the Q-E coverage of the current instrument suite and facilitate the study of inelastic and quasi-elastic scatterings at low Q values. The possible location for the proposed instrument is either beamline 8 which views the decoupled water moderator, or beamline 14A, which views a cold, coupled super critical hydrogen moderator. The instrument parameters, optimizations, and performances at these two beamline locations are discussed.

43 PARTICLE ACCELERATORS↗

FRIB cryogenic distribution system

The Michigan State University Facility for Rare Isotope Beams (MSU-FRIB) helium distribution system has been revised to include bayonet/warm valve type disconnects between each cryomodule and the transfer line distribution system, similar to the Thomas Jefferson National Accelerator Facility (JLab) and the Spallation Neutron Source (SNS) cryogenic distribution systems. The heat loads at various temperature levels and some of the features in the design of the distribution system are outlined. The present status, the plans for fabrication, and the procurement approach for the helium distribution system are also included.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Very low electron temperature in warm dense matter formed by focused picosecond soft x-ray laser pulses

We investigated the optical emission from the ablating surfaces induced by the irradiations of soft x-ray laser (SXRL) pulses with the aim of estimation of the maximum electron temperature. No emission signal in the spectral range of 400–800 nm could be observed despite the formation of damage structures on the target surfaces. Hence, we estimated an upper limit for the electron temperature of 0.4–0.7 eV for the process duration of 100–1000 ps. Our results imply that the ablation and/or surface modification by the SXRL is not accompanied by plasma formation but is induced by thermo-mechanical pressure, which is so called a spallative ablation. This spallative ablation process occurs in the low electron temperature region of a non-equilibrium state of warm dense matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Requirements and sensitivity analysis for temporally- and spatially-resolved thermometry using neutron resonance spectroscopy

Neutron resonance spectroscopy (NRS) has been used extensively to make temperature measurements that are accurate, absolute, and nonperturbative within the interior of material samples under extreme conditions applied quasistatically. Yet NRS has seldom been used in dynamic experiments. There is a compelling incentive to do so because of the significant shortcomings of alternative techniques. An important barrier to adopting dynamic NRS thermometry is the difficulty in fielding it with conventional spallation neutron sources. To enable time-dependent and spatially resolved temperature measurements in dynamic environments, more compact neutron sources that can be used at user facilities in conjunction with other diagnostic probes (such as x-ray light sources) are required. Such sources may be available using ultrafast high-intensity optical lasers. We evaluate such possibilities by determining the sensitivities of the temperature estimate on neutron-beam and diagnostic parameters. Based on that evaluation, requirements are set on a pulsed neutron-source and diagnostics to make a meaningful dynamic temperature measurement. Dynamic thermometry measurements are examined in this context when driven by two alternative fast-neutron sources: the Los Alamos Neutron Scattering Center (LANSCE) proton accelerator driving isotropic spallation neutrons as a baseline and a laser-plasma ion accelerator driving a neutron beam from deuterium breakup. Strategies to close the gap between the required and demonstrated performance of laser-based fast-neutron sources are presented. A short-pulse high-intensity laser with state-of-the-art pulse contrast and an energy of a few hundred Joules would drive a compact neutron source suitable for NRS thermometry that could transform the dynamic study of materials.

47 OTHER INSTRUMENTATION↗

Next-generation diamond cell and applications to single-crystal neutron diffraction

In this paper, a diamond cell optimized for single-crystal neutron diffraction is described. It is adapted for work at several of the single-crystal diffractometers of the Spallation Neutron Source and the High Flux Isotope Reactor at the Oak Ridge National Laboratory (ORNL). A simple spring design improves portability across the facilities and affords load maintenance from offline pressurization and during temperature cycling. Compared to earlier prototypes, pressure stability of polycrystalline diamond (Versimax®) has been increased through double-conical designs and ease of use has been improved through changes to seat and piston setups. These anvils allow ~30%-40% taller samples than possible with comparable single-crystal anvils. Hydrostaticity and the important absence of shear pressure gradients have been established with the use of glycerin as a pressure medium. Large single-crystal synthetic diamonds have also been used for the first time with such a clamp-diamond anvil cell for pressures close to 20 GPa. The cell is made from a copper beryllium alloy and sized to fit into ORNL’s magnets for future ultra-low temperature and high-field studies. Finally, we show examples from the Spallation Neutron Source’s SNAP and CORELLI beamlines and the High Flux Isotope Reactor’s HB-3A and IMAGINE beamlines.

36 MATERIALS SCIENCE↗

3D-printed B 4 C collimation for neutron pressure cells

A design for an incident-beam collimator for the Paris–Edinburgh pressure cell is described here. This design can be fabricated from reaction-bonded B 4 C but also through fast turnaround, inexpensive 3D-printing. 3D-printing thereby also offers the opportunity of composite collimators whereby the tip closest to the sample can exhibit even better neutronic characteristics. Here, we characterize four such collimators: one from reaction-bonded B 4 C, one 3D-printed and fully infiltrated with cyanoacrylate, a glue, one with a glue-free tip, and one with a tip made from enriched 10 B 4 C. The collimators are evaluated on the Spallation Neutrons and Pressure Diffractometer of the Spallation Neutron Source and the Wide-Angle Neutron Diffractometer at the High Flux Isotope Reactor, both at Oak Ridge National Laboratory. This work clearly shows that 3D-printed collimators perform well and also that composite collimators improve performance even further. Beyond use in the Paris–Edinburgh cell, these findings also open new avenues for collimator designs as clearly more complex shapes are possible through 3D printing. An example of such is shown here with a collimator made for single-crystal samples measured inside a diamond anvil cell. These developments are expected to be highly advantageous for future experimentation in high pressure and other extreme environments and even for the design and deployment of new neutron scattering instruments.

47 OTHER INSTRUMENTATION↗

H- ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced by spallation of liquid Hg due to bombardment of short (~1µs), intense (~35 A) pulses of protons delivered at 60 Hz from a storage ring which is fed by a high-intensity, 1 GeV H- LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50-60 mA of H- ions with a duty-factor of 6% for maintenance-free runs of ~120 days with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting these achievements: this report provides some historical highlights of this effort, describes our current ion source testing facilities, discusses the goals of the program and finally provides a snapshot of some of our ongoing R&D activities. In particular, we have recently simplified and improved the reliability of the plasma ignition gun for the external antenna ion source which is discussed in detail.

Welton, Robert F.↗

Methods for neutron diffraction studies on hydride superconductors and other metal hydrides

High-pressure neutron diffraction is an extremely useful technique in the quest for making and understanding novel hydride superconductors. Neutron diffraction can be used to directly determine elemental stoichiometries and atomic positions of many light elements such as hydrogen or deuterium, even in the presence of heavy elements such as rare-earth metals. In this work, we report on the current status and ongoing developments on high-pressure neutron diffraction for hydride superconductors and other metal hydrides with a special focus on current advancements at the Spallation Neutrons and Pressure (SNAP) beamline of the Spallation Neutron Source at Oak Ridge National Laboratory. For broader context, an overview of high-pressure neutron diffractometers and pressure cells is included together with insight into critical sample considerations. There, attention is given to the requirements for powdered hydride samples and the need for deuterium rather than hydrogen. Additionally, the advantages of angular access and data representation as possible at SNAP are described. We demonstrate the current capability for high-pressure neutron diffraction on two different samples created via hydrogen gas loading, specifically pure deuterium and nickel-deuteride. The deuterium example highlights the usefulness of adding sample materials that facilitate the formation of a good powder while the nickel-deuteride example demonstrates that atomic deuterium positions and stoichiometry can be directly determined. Both examples highlight the importance of large scattering apertures. These enable investigation of the data resolved by scattering angle that is needed to identify parasitic peaks and background features. Finally, future directions beyond current high-pressure neutron powder diffraction are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗

Analysis of Second Target Station Target Removal Dose Rates

The Second Target Station (STS) project at Oak Ridge National Laboratory’s spallation neutron source is a crucial initiative for maintaining U.S. leadership in neutron sciences. The STS aims to create the world’s brightest pulsed cold neutron source, enabling cutting-edge research across various scientific disciplines. To ensure safe and efficient maintenance operations, understanding the effects of shutdown dose rates from activated components within the STS target systems is essential. This study establishes a computational framework for calculating decay gamma sources and subsequent shutdown dose rates utilizing advanced methods to account for all activation channels, including high-energy interactions down to thermal neutron capture. This study describes a novel integration of multiple tools and provides an effective means of analyzing activation and shutdown dose rates at spallation neutron facilities. A custom-developed script automates the decay gamma source generation process, ensuring proper sampling during the variance reduction phase, which is critical for accurate predictions of shutdown dose rates.

Transmutation↗

Diffusive propagation of cosmic rays from supernova remnants in the Galaxy. I: spectrum and chemical composition

In this paper we investigate the effect of stochasticity in the spatial and temporal distribution of supernova remnants on the spectrum and chemical composition of cosmic rays observed at Earth. The calculations are carried out for different choices of the diffusion coefficient D(E) experienced by cosmic rays during propagation in the Galaxy. In particular, at high energies we assume that D(E)∝E{sup δ}, with δ = 1/3 and δ = 0.6 being the reference scenarios. The large scale distribution of supernova remnants in the Galaxy is modeled following the distribution of pulsars, with and without accounting for the spiral structure of the Galaxy. We find that the stochastic fluctuations induced by the spatial and temporal distribution of supernovae, together with the effect of spallation of nuclei, lead to mild but sensible violations of the simple, leaky-box-inspired rule that the spectrum observed at Earth is N(E)∝E{sup −α} with α = γ+δ, where γ is the slope of the cosmic ray injection spectrum at the sources. Spallation of nuclei, even with the small rates appropriate for He, may account for small differences in spectral slopes between different nuclei, possibly providing an explanation for the recent CREAM observations. For δ = 1/3 we find that the slope of the proton and helium spectra are ∼ 2.67 and ∼ 2.6 respectively (with fluctuations depending on the realization of source distribution) at energies around ∼ 1 TeV (to be compared with the measured values of 2.66±0.02 and 2.58±0.02). For δ = 0.6 the hardening of the He spectra is not observed. The stochastic effects discussed above cannot be found in ordinary propagation calculations, such as GALPROP, where these effects and the point like nature of the sources are not taken into account. We also comment on the effect of time dependence of the escape of cosmic rays from supernova remnants, and of a possible clustering of the sources in superbubbles. In a second paper we will discuss the implications of these different scenarios for the anisotropy of cosmic rays.

79 ASTRONOMY AND ASTROPHYSICS↗

Raman Spectroscopy as an ortho-para diagnostic of liquid hydrogen moderators

The intense radiation environment of a neutron moderator provides a mechanism for significant up-conversion of parahydrogen to orthohydrogen inside the moderator, as well as intrinsically catalyzing relaxation of orthohydrogen to parahydrogen. It is plausible that the steady-state orthohydrogen fraction of a moderator in a radiation environment such as at the Spallation Neutron Source (SNS) or the European Spallation Source (ESS) is as high as 30 % without supplemental catalysis. Direct measurement of the orthohydrogen fraction in the liquid hydrogen flow itself is essential to predict and monitor moderator performance, especially for thick or flat moderator concepts such as the ones that have been proposed for the ESS and for upgrades to the SNS. Raman spectroscopy provides a well-known method for directly measuring the hydrogen make-up in an unambiguous way. We describe our tests of Raman spectroscopy for application to the measurement of the orthohydrogen fraction of the hydrogen moderators at SNS and at the ESS. As part of this work, we have additionally developed a sample holder that has been used to perform simultaneous Raman and neutron vibrational spectroscopy on the VISION spectrometer at SNS. We discuss our plans to incorporate such a system as a diagnostic for liquid hydrogen moderators at SNS and at the ESS.

Gillis, Robert Chad↗