Search NASA⌕ Search

SEARCH · Search NASA

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Direct Simulation Monte Carlo Studies of the Gas Sampling for the VATMOS-SR Mission Concept

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small spacecraft mission concept which would return a gas sample from the upper atmosphere of Venus to Earth for scientific analysis. This could be the first sample return mission for an extra-terrestrial atmosphere, and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and acquire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen. This presentation will discuss hypervelocity sampling in the upper atmosphere of Venus, with respect to the VATMOS-SR mission concept. VATMOS-SR would enable critical atmospheric measurements to form a full picture of how, why, and when Venus evolved to be so different from Earth and Mars. The abundances and isotopic compositions of volatile elements (such as N, C, S, O and the noble gases) in planetary atmospheres record volatile delivery during accretion, outgassing from planetary interiors, and atmospheric loss to space. Precise and accurate determinations of atmospheric volatile signatures are the key to understanding the origins and geodynamical evolution of Venus compared to the other terrestrial planets. Hypersonic sampling poses unique technical and scientific challenges. To ensure it is possible to relate the composition of the sampled gases to the free stream atmospheric composition, large-scale numerical simulations are employed to model the flow through the VATMOS-SR sampling system. In particular, an emphasis is placed on quantifying noble gas isotopic fractionation that occurs during the sample acquisition and transfer process in order to determine how measured isotopic ratios of noble gases in the sample compare to actual isotopic ratios in the Venusian atmosphere. The Direct Simulation Monte Carlo (DSMC) code SPARTA, an open source software package developed by Sandia National Laboratories, is used in this work. SPARTA, based on Bird’s DSMC method, is a molecular-level gas-kinetic technique. As SPARTA is able to model hypervelocity reacting flows in strong chemical and thermal non-equilibrium, this software package is well suited to determine relevant flow properties for the VATMOS-SR mission concept, and to numerically quantify the expected level of elemental and/or isotopic fractionation in the sample acquired by VATMOS-SR. This presentation will show results from 3D simulations correlating the noble gas isotopic fractionation in the gas acquired at hypervelocity speeds to its ambient atmosphere value. In particular, emphasis will be placed at Xenon isotopes of masses 128 and 130, as precise measurements of that ratio would yield a comparison to Earth’s atmosphere. Additionally, sensitivity studies that quantify the uncertainties due to the freestream parameters as well as the modeling parameters will be performed.

direct simulation Monte Carlo↗

The VATMOS-SR Mission Concept: DSMC Studies of the Gas Sampling

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small spacecraft mission concept that would return a gas sample from the upper atmosphere of Venus to Earth for scientific analysis. This could be the first sample return mission for an extra-terrestrial atmosphere and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and acquire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen. This presentation will discuss hypervelocity sampling in the upper atmosphere of Venus with respect to the VATMOS-SR mission concept. VATMOS-SR would enable critical atmospheric measurements to form a complete picture of how, why, and when Venus evolved to be so different from Earth and Mars. The abundances and isotopic compositions of volatile elements (such as N, C, S, O, and the noble gases) in planetary atmospheres record volatile delivery during accretion, outgassing from planetary interiors, and atmospheric loss to space. Precise and accurate determinations of volatile atmospheric signatures are the key to understanding the origins and geodynamical evolution of Venus compared to the other terrestrial planets. Hypersonic sampling poses unique technical and scientific challenges. To ensure it is possible to relate the composition of the sampled gases to the free stream atmospheric composition, large-scale numerical simulations are employed to model the flow through the VATMOS-SR sampling system. In particular, an emphasis is placed on quantifying noble gas isotopic fractionation that occurs during the sample acquisition and transfer process to determine how measured isotopic ratios of noble gases in the sample compared to actual isotopic ratios in the Venusian atmosphere. The Direct Simulation Monte Carlo (DSMC) code SPARTA, an open-source software package developed by Sandia National Laboratories, is used in this work. SPARTA, based on Bird’s DSMC method, is a molecular-level gas-kinetic technique. As SPARTA is able to model hypervelocity reacting flows in strong chemical and thermal non-equilibrium, this software package is well suited to determine relevant flow properties for the VATMOS-SR mission concept and to numerically quantify the expected level of elemental and/or isotopic fractionation in the sample acquired by VATMOS-SR. This presentation will show results from 3D simulations correlating the noble gas isotopic fractionation in the gas acquired at hypervelocity speeds to its ambient atmosphere value. In particular, emphasis will be placed on Xenon isotopes of masses 128 and 130, as precise measurements of that ratio would yield comparison to Earth’s atmosphere. Additionally, sensitivity studies that quantify the uncertainties due to the freestream parameters, as well as the modeling parameters, will be performed.

direct simulation Monte Carlo↗

Sensing and Sampling of Trace Contaminations by a Dexterous Hexrotor UAV at Nuclear Facilities - 18600

Safe and efficient cleanups are a priority for decontamination and decommissioning of nuclear facilities. The contaminations of byproducts and wastes in such nuclear facilities pose a serious problems while decommissioning, to both the operators and public. Sensing these contaminations and cleaning them is an essential part of the safety procedures. The contaminations might range from low-energy to high-energy byproducts. Sensing these byproducts would require contact based or non-contact based sensing, based on its energy levels. Byproducts such as americium, are low-energy which makes it difficult to sense and sample without contact. Therefore, the workers need to physically swab the surfaces to collect the samples of these contaminations. These tasks pose a great danger for the safety of the human workers which includes the risk to reach greater heights, exposure to the radiation and sampling the entire building. A robotic solution is much more desirable in these cases, where the worker can safely handle the contaminations from a safe area. Use of robotic technologies inside these hazardous environments ensures the safety and enhances the performance. The more suitable robotic solution for reaching great heights and covering large areas of nuclear facilities, are aerial vehicles. Multi-rotor unmanned aerial vehicle (UAV) are chosen for their ability to hover at a position and also fly around in confined spaces. Quadrotors are a common choice of multi-rotor UAVs both research and industry because of its ease to fly and commercial availability. For the applications during the cleanups we need the UAV to not only hover and fly in confined spaces, but also interact with the physical world. Despite of quadrotor's advantages, they are not a best suit as they can't interact with the physical world. The tasks involving physical interactions would require the UAV to apply arbitrary forces and torques in all six degrees of freedom (DOF). As quadrotors are under-actuated and non-holonomic in motion, they cannot exert all the required forces. At Collaborative Robotics Lab, Purdue University, we developed a novel multi-rotor UAV solution, Dexterous Hexrotor, which can exert arbitrary forces and torques in all six DOF, independently and instantaneously. This enables the UAV platform to quickly respond to the external disturbances and precisely hold its position during the mission. The Dexterous Hexrotor serves as a robotic tool for the workers to perform sensing and sampling during the cleanups. Workers can operate Dexterous Hexrotor manually and/or semi-autonomously with human intervention. Manual control requires the worker to fly the Dexterous Hexrotor using a remote control. So the workers should possess knowledge on flying the UAV and to perform physical interaction. A semiautonomous Dexterous Hexrotor requires human input to some extent and requires very less knowledge of flying. The autonomy is designed to operate in flight mode and sampling mode. In flight mode, Dexterous Hexrotor takes off from a 'safe' area, reaches the desired altitude, and fly autonomously towards a sampling point. This sampling point is the target position specified on the 2D reference map. This mode also includes navigation towards the sampling point, avoiding the obstacles in the constrained environment. After reaching a stopping point, Dexterous Hexrotor waits for the human input for a target location to swab and collect samples. The Dexterous Hexrotor is now in sampling mode and waits for the human input. The human operator selects the swabbing location through the live streaming video from onboard camera. Through visual servoing, aided by the map, the UAV will move closer towards the target position. It then transitions to the impact control scheme to perform physical interaction with the wall and collects samples. Once the sample is collected, it autonomously returns back to the takeoff position in 'safe' area for the analysis by mass spectrometry. In this paper, we majorly focus on the physical interaction strategy and the required components which enables the autonomy. Decommissioning of nuclear facilities requires decontamination inside the entire buildings. Decontamination of nuclear facilities involves sensing and sampling the huge buildings, long shafts, etc. Sampling the entire facility is not possible due to the limitation in Dexterous Hexrotor's flight time. But this can be achieved by using a swarm of Dexterous Hexrotors to cover larger areas. The onboard robotic arm can be designed based on the applications such as cleaning, applying sealants, etc. The modularity of the design allows us to switch components as per the requirements of the task. These kind of robotic solutions functioning as tools for the workers, aims to make the work environment safer and playful. (authors)

42 ENGINEERING↗

Sampling and Analysis Plan for Investigation of Undeclared Nuclear Activities - 20104

The nuclear-centered energy policy in South Korea is moving towards a nuclear-free era. It also facilitates an action or progress on the denuclearization of the Korean peninsula. The Nuclear Safety and Security Commission (NSSC) launched a new R and D project which attempts to verify nuclear activities via analyzing environmental samples. Environmental samples possibly contain significant radiological information relevant to past undeclared activities. In order to precisely verify them, it is essential to provide 1) the concrete information of target facilities, 2) appropriate methodologies and procedures, and 3) well-suited instrumentation and equipment corresponding to sample signatures. It is also important to provide scientific reliability or validity in any process such as sample collection, handling, transportation and laboratory analysis. Therefore, the information of nuclear facilities (fuel fabrication plant, graphite moderated reactor, reprocessing plant) in North Korea are reviewed in order to determine parameters for appropriate sampling methods representing a facility's characteristics. Secondly, a sampling procedure for radioactive elements is being developed based on international and domestic standards such as ASTM (American Society for Testing and Materials), KS (Korean industrial Standards), and International Atomic Energy Agency (IAEA) manuals. The procedure contains some specific information including sampling process, sampling tools, amount of sample, sample identification, and other related information. Developing the qualified national guidelines is most important since sampling and analyzing results can be used as evidences of nuclear activities. The guideline developed through this work will clearly define various methodologies such as document verification, sampling procedures, collection methods, sample storage criteria, chain of custody, and transportation conditions. The final objective of this work is to establish the infrastructure and regulatory framework for assessment of nuclear activities, and provide a national guideline for sampling and analysis. This will bring confidence in the results and play a critical role in complete denuclearization progress in South Korea. (authors)

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Applications of Hyporheic Zone Sampling for Assessing VOC Plume Engineered Remediation and Natural Attenuation Effectiveness - 20414

Determining the efficacy of engineered remedial actions and/or natural attenuation as an acceptable EPA Record of Decision (ROD) must address long-term temporal and spatial variability. Since final plume downslope destinations are aquifers and related surface streams and rivers, hyporheic zone sampling is essential. Comprehensive hyporheic sampling documents plume groundwater remediation prior to upwelling into stream benthic strata and natural attenuation within this dynamic zone itself. Our intensive sampling of the Savannah River Site (SRS) Chemical, Metals, and Pesticides (CMP) Pits VOC plume-fringe from 2005 to 2018 documented PCE natural attenuation and effectiveness of In Situ Thermal Treatment (ISTT). Most plume hyporheic upwelling was delimited to a 20 m inflow reach along Pen Branch. Our study utilized corroborative sampling methodologies: ambient hole-water grab samples: passive diffusion bags (PDB); and hole-core sediment samples to confirm station to station spatial and temporal trends. VOC hot spot detections were confirmed from both groundwater and soil core samples. VOC pathways through the Pen Branch hyporheic zone were assessed at hole-installation using sequential soil samples from augered cores and grab-samples of hole-bottom water. Longer term, composite water samples were collected from PDBs deployed for a minimum two-week equilibration period. Soil samples were collected from the 15 and 65 cm core levels in December 2017 and June 2018 at six stations. Additional core depths of 40 and 85 cm were sampled in June 2018 at the highest VOC station (5DB80). All samples were analyzed in an EPA certified lab by purge and trap GC-MS. Effectiveness of previous ISTT and soil vapor extraction (SVE) for this CMP Pits PCE plume, was clearly documented by significant downward trends in VOC at hyporheic zone stations prior to December 2015. Achieving final stage conversions of PCE daughter products to ethene and CO{sub 2} may be limited depending upon suitable interactions between hyporheic zone sediment morphology, hydrology, and redox conditions. Because declines in VOC daughter products at our hyporheic stations may also be caused by physical actions of dilution and dispersion rather than true biochemical dechlorination, full quantification of natural attenuation requires the use of compound-specific isotope ratio analysis (CSIA) and microbial 16S rRNA with qPCR. To assist these next-phase efforts, a natural attenuation index (NAI) was used to help produce quicker, more cost-effective decision making for locating CSIA and microbial sampling efforts. The NAI used natural logarithm transformed GC-MS results for station VOC degradation compounds versus VOC parent compounds. Wide differences were observed between stations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultrathin aluminum sample cans for single crystal inelastic neutron scattering

Single crystal inelastic neutron scattering measurements are often performed using a sample environment for controlling sample temperature. One difficulty associated with this is establishing appropriate thermal coupling from the sample to the temperature controlled portion of the sample environment. This is usually accomplished via a sample can which thermally couples the sample environment to the sample can and the sample can to the sample via an exchange gas. Unfortunately, this can will contribute additional background signal to ones measurement. We present here the design of an ultrathin aluminum sample can based upon established technology for producing aluminum beverage cans. This design minimizes parasitic sample can scattering. Neutron scattering measurements comparing a machined sample can to our beverage can design clearly indicate a large reduction in scattering intensity and texture when using the ultrathin sample can design. We also examine the possibility of using standard commercial beverage cans as sample cans.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Examination of Hydrate Formation Methods: Trying to Create Representative Samples

Forming representative gas hydrate-bearing laboratory samples is important so that the properties of these materials may be measured, while controlling the composition and other variables. Natural samples are rare, and have often experienced pressure and temperature changes that may affect the property to be measured. Forming methane hydrate samples in the laboratory has been done a number of ways, each having advantages and disadvantages. The ice-to-hydrate method, contacts melting ice with methane at the appropriate pressure to form hydrate. The hydrate can then be crushed and mixed with mineral grains under controlled conditions, and then compacted to create laboratory samples of methane hydrate in a mineral medium. The hydrate in these samples will be part of the load-bearing frame of the medium. In the excess gas method, water is distributed throughout a mineral medium (e.g. packed moist sand, drained sand, moistened silica gel, other porous media) and the mixture is brought to hydrate-stable conditions (chilled and pressurized with gas), allowing hydrate to form. This method typically produces grain-cementing hydrate from pendular water in sand. In the dissolved gas method, water with sufficient dissolved guest molecules is brought to hydrate-stable conditions where hydrate forms. In the laboratory, this is can be done by pre-dissolving the gas of interest in water and then introducing it to the sample under the appropriate conditions. With this method, it is easier to form hydrate from more soluble gases such as carbon dioxide. It is thought that this method more closely simulates the way most natural gas hydrate has formed. Laboratory implementation, however, is difficult, and sample formation is prohibitively time consuming. In another version of this technique, a specified quantity of gas is placed in a sample, then the sample is flooded with water and cooled. We have performed a number of tests in which hydrate was formed and the uniformity of the hydrate formation was examined. These tests have primarily used a variety of modifications of the excess gas method to make the hydrate, although we have also used a version of the excess water technique. Early on, we found difficulties in creating uniform samples with a particular sand/ initial water saturation combination (F-110 Sand, ~ 35% initial water saturation). In many of our tests we selected this combination intentionally to determine whether we could use a method to make the samples uniform. The following methods were examined: • Excess gas, • Freeze/thaw/form, • Freeze/pressurize/thaw, • Excess gas followed by water saturation, • Excess water, • Sand and kaolinite, • Use of a nucleation enhancer (SnoMax), and • Use of salt in the water. Below, each method, the underlying hypothesis, and our results are briefly presented, followed by a brief conclusion. Many of the hypotheses investigated are not our own, but were presented to us. Much of the data presented is from x-ray CT scanning our samples. The x-ray CT scanner provides a three-dimensional density map of our samples. From this map and the physics that is occurring in our samples, we are able to gain an understanding of the spatial nature of the processes that occur, and attribute them to the locations where they occur.

03 NATURAL GAS↗

Analysis of the Tank 6F Final Characterization Samples-2012 (U)

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 6F final characterization samples to determine the residual tank inventory prior to grouting. Fourteen residual Tank 6F solid samples from three areas on the floor of the tank were collected and delivered to SRNL between May and August 2011. These Tank 6F samples were homogenized and combined into three composite samples based on a proportion compositing scheme and the resulting composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 6F composite samples include bulk density and water leaching of the solids to account for water soluble components. The composite Tank 6F samples were analyzed and the data reported in triplicate. Sufficient quality assurance standards and blanks were utilized to demonstrate adequate characterization of the Tank 6F samples. The main evaluation criteria were target detection limits specified in the technical task request document. While many of the target detection limits were met for the species characterized for Tank 6F some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The isotopes whose detection limits were not met in all cases included Sn-126, Sb-126, Sb-126m, Eu-152, Cm-243 and Cf-249. SRNL, in conjunction with the customer, reviewed all of these cases and determined that the impacts of not meeting the target detection limits were acceptable. Based on the analyses of variance (ANOVA) for the inorganic constituents of Tank 6F, all the inorganic constituents displayed heterogeneity. The inorganic results demonstrated consistent differences across the composite samples: lowest concentrations for Composite Sample 1, intermediate-valued concentrations for Composite Sample 2, and highest concentrations for Composite Sample 3. The Hg and Mo results suggest possible measurement outliers. However, the magnitudes of the differences between the Hg 95% upper confidence limit (UCL95) results with and without the outlier and the magnitudes of the differences between the Mo UCL95 results with and without the outlier do not appear to have practical significance. It is recommended to remove the potential measurement outliers. Doing so is conservative in the sense of producing a higher UCL95 for Hg and Mo than if the potential outliers were included in the calculations. In contrast to the inorganic results, most of the radionuclides did not demonstrate heterogeneity among the three Tank 6F composite sample characterization results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the Tank 6F Final Characterization Samples-2012

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 6F final characterization samples to determine the residual tank inventory prior to grouting. Fourteen residual Tank 6F solid samples from three areas on the floor of the tank were collected and delivered to SRNL between May and August 2011. These Tank 6F samples were homogenized and combined into three composite samples based on a proportion compositing scheme and the resulting composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 6F composite samples include bulk density and water leaching of the solids to account for water soluble components. The composite Tank 6F samples were analyzed and the data reported in triplicate. Sufficient quality assurance standards and blanks were utilized to demonstrate adequate characterization of the Tank 6F samples. The main evaluation criteria were target detection limits specified in the technical task request document. While many of the target detection limits were met for the species characterized for Tank 6F some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The isotopes whose detection limits were not met in all cases included Sn-126, Sb-126, Sb-126m, Eu-152, Cm- 243 and Cf-249. SRNL, in conjunction with the customer, reviewed all of these cases and determined that the impacts of not meeting the target detection limits were acceptable. Based on the analyses of variance (ANOVA) for the inorganic constituents of Tank 6F, all the inorganic constituents displayed heterogeneity. The inorganic results demonstrated consistent differences across the composite samples: lowest concentrations for Composite Sample 1, intermediate-valued concentrations for Composite Sample 2, and highest concentrations for Composite Sample 3. The Hg and Mo results suggest possible measurement outliers. However, the magnitudes of the differences between the Hg 95% upper confidence limit (UCL95) results with and without the outlier and the magnitudes of the differences between the Mo UCL95 results with and without the outlier do not appear to have practical significance. It is recommended to remove the potential measurement outliers. Doing so is conservative in the sense of producing a higher UCL95 for Hg and Mo than if the potential outliers were included in the calculations. In contrast to the inorganic results, most of the radionuclides did not demonstrate heterogeneity among the three Tank 6F composite sample characterization results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Handbook: Collecting Groundwater Samples from Monitoring Wells in Frenchman Flat, CAU 98

Frenchman Flat basin on the Nevada National Security Site (NNSS) contains Corrective Action Unit (CAU) 98, which is comprised of ten underground nuclear test locations. Environmental management of these test locations is part of the Underground Test Area (UGTA) Activity conducted by the U.S. Department of Energy (DOE) under the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended) with the U.S. Department of Defense (DOD) and the State of Nevada. A Corrective Action Decision Document (CADD)/Corrective Action Plan (CAP) has been approved for CAU 98 (DOE, 2011). The CADD/CAP reports on the Corrective Action Investigation that was conducted for the CAU, which included characterization and modeling. It also presents the recommended corrective actions to address the objective of protecting human health and the environment. The recommended corrective action alternative is “Closure in Place with Modeling, Monitoring, and Institutional Controls.” The role of monitoring is to verify that Contaminants of Concern (COCs) have not exceeded the Safe Drinking Water Act (SDWA) limits (Code of Federal Regulations, 2014) at the regulatory boundary, to ensure that institutional controls are adequate, and to monitor for changed conditions that could affect the closure conditions. The long-term closure monitoring program will be planned and implemented as part of the Closure Report stage after activities specified in the CADD/CAP are complete. Groundwater at the NNSS has been monitored for decades through a variety of programs. Current activities were recently consolidated in an NNSS Integrated Sampling Plan (DOE, 2014). Although monitoring directed by the plan is not intended to meet the FFACO long-term monitoring requirements for a CAU (which will be defined in the Closure Report), the objective to ensure public health protection is similar. It is expected that data collected in accordance with the plan will support the transition to long-term monitoring at each CAU. The sampling plan is designed to ensure that monitoring activities occur in compliance with the UGTA Quality Assurance Plan (DOE, 2012). The sampling plan should be referenced for Quality Assurance (QA) elements and procedures governing sampling activities. The NNSS Integrated Sampling Plan specifies the groundwater monitoring that will occur in CAU 98 until the long-term monitoring program is approved in the Closure Report. The plan specifies the wells that must be monitored and categorizes them by their sampling objective with the associated analytical requirements and frequency. Possible sample collection methods and required standard operating procedures are also presented. The intent of this handbook is to augment the NNSS Integrated Sampling Plan by providing well-specific details for the sampling professional implementing the Sampling Plan in CAU 98, Frenchman Flat. This handbook includes each CAU 98 well designated for sampling in the NNSS Integrated Sampling Plan. The following information is provided in the individual well sections: 1. The purpose of sampling. 2. A physical description of the well. 3. The chemical characteristics of the formation water. 4. Recommended protocols for purging and sampling. The well-specific information has been gathered from numerous historical and current sources cited in each section, but two particularly valuable resources merit special mention. These are the USGS NNSS website (http://nevada.usgs.gov/doe_nv/ntsarea5.cfm) and the UGTA Field Operations website (https://ugta.nv.doe.gov/sites/Field%20Operations/default.aspx). 2 Land surface elevation and measuring point for water level measurements in Frenchman Flat were a focus during CAU investigations (see Appendix B, Attachment 1 in Navarro-Intera, 2014). Both websites listed above provide information on the accepted datum for each well. A summary is found on the home page for the well on the USGS website. Additional information is available through a link in the “Available Data” section to an “MP diagram” with a photo annotated with the datum information. On the UGTA Field Operations well page, the same information is in the “Wellhead Diagram” link. Well RNM-2s does not have an annotated photo at this time. All of the CAU 98 monitoring wells are located within Area 5 of Frenchman Flat, with the exception of ER-11-2 in Area 11 (Figure 1). The wells are clustered in two areas: the northern area (Figure 2) and the central area (Figure 3). Each well is discussed below in geographic order from north to south as follows: ER-11-2, ER-5-3 shallow piezometer, ER-5-3-2, ER-5-5, RNM-1, RNM-2s, and UE-5n.

(1996↗

Analysis of the 2H-evaporator scale samples (HTF-17-56, -57)

Savannah River National Laboratory analyzed scale samples from both the wall and cone sections of the 242-16H Evaporator prior to chemical cleaning. The samples were analyzed for uranium and plutonium isotopes required for a Nuclear Criticality Safety Assessment of the scale removal process. The analysis of the scale samples found the material to contain crystalline nitrated cancrinite and clarkeite. Samples from both the wall and cone contain depleted uranium. Uranium concentrations of 16.8 wt% 4.76 wt% were measured in the wall and cone samples, respectively. The ratio of plutonium isotopes in both samples is ~85% Pu-239 and ~15% Pu-238 by mass and shows approximately the same 3.5 times higher concentration in the wall sample versus the cone sample as observed in the uranium concentrations. The mercury concentrations measured in the scale samples were higher than previously reported values. The wall sample contains 19.4 wt% mercury and the cone scale sample 11.4 wt% mercury. The results from the current scales samples show reasonable agreement with previous 242-16H Evaporator scale sample analysis; however, the uranium concentration in the current wall sample is substantially higher than previous measurements.

2H evaporator system↗

Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO 2 F 2 and UO 2 (NO 3 ) 2 , U 3 O 8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO 2 F 2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Optimal spatial sampling techniques for ground truth data in microwave remote sensing of soil moisture

The paper examines optimal sampling techniques for obtaining accurate spatial averages of soil moisture, at various depths and for cell sizes in the range 2.5-40 acres, with a minimum number of samples. Both simple random sampling and stratified sampling procedures are used to reach a set of recommended sample sizes for each depth and for each cell size. Major conclusions from statistical sampling test results are that (1) the number of samples required decreases with increasing depth; (2) when the total number of samples cannot be prespecified or the moisture in only one single layer is of interest, then a simple random sample procedure should be used which is based on the observed mean and SD for data from a single field; (3) when the total number of samples can be prespecified and the objective is to measure the soil moisture profile with depth, then stratified random sampling based on optimal allocation should be used; and (4) decreasing the sensor resolution cell size leads to fairly large decreases in samples sizes with stratified sampling procedures, whereas only a moderate decrease is obtained in simple random sampling procedures.

Rao, R. G. S.↗

Horizons and Opportunities in Lunar Sample Science

The Moon is the cornerstone of planetary science. Lunar sample studies were fundamental in developing an understanding of the early evolution and continued development of planetary bodies, and have led to major revisions in understanding of processes for the accumulation of planetesimals and the formation of planets. Studies of lunar samples have increased an understanding of impact cratering, meteoroid and micrometeoroid fluxes, the interaction of planetary surfaces with radiations and particles, and even the history of the Sun. The lunar sample research program was especially productive, but by no means have all the important answers been determined; continued study of lunar samples will further illuminate the shadows of our knowledge about the solar system. Further, the treasures returned through the Apollo program provide information that is required for a return to the Moon, beginning with new exploration (Lunar Geoscience Observer (LGO)), followed by intensive study (new sample return missions), and eventually culminating in a lunar base and lunar resource utilization. The few years during and following Apollo were a hectic time for lunar science. Since then, considerable maturation of the science and distinct changes in the mode of operation have developed. Funding (and hence the number of investigators) has naturally declined. Studies have become far more problem-oriented than descriptive. Many sample investigators have shifted their sights away from planetary evolution, for which the Moon holds considerable information, toward processes and materials in the pre-planetary solar nebula, for which the Moon has no direct evidence. Nonetheless, unique scientific opportunities are still supplied by the samples returned from the Apollo and Luna missions and by lunar meteorites. These 382 kg of samples constitute a priceless resource that still has enormous scientific potential. Continued interaction between NASA and the scientific community, especially through the advice of groups such as the Lunar and Planetary Sample Team (LAPST), is essential in maintaining the current level of excellence of the program. LAPST has reviewed its role, the role of the sample research community, and the perceived role of future researchers over the next decade in ensuring the effective use of lunar sample studies in space exploration and exploitation. The review encompasses: (I) lunar sample science; (2) lunar materials applications; (3) lunar sample studies and their relation to future space missions; and (4) lunar sample curation. Plans in all four areas are summarized in this document.

Source record↗

Mission Design Overview for Mars 2003/2005 Sample Return Mission

In May 2003, a new and exciting chapter in Mars exploration will begin with the launch of the first of three spacecraft that will collectively contribute toward the goal of delivering samples from the Red Planet to Earth. This mission is called Mars Sample Return (MSR) and will utilize both the 2003 and 2005 launch opportunities with an expected sample return in October 2008. NASA and CNES are major partners in this mission. The baseline mission mode selected for MSR is Mars orbit rendezvous (MOR), analogous in concept to the lunar orbit rendezvous (LOR) mode used for Apollo in the 1960s. Specifically, MSR will employ two NASA-provided landers of nearly identical design and one CNES-provided orbiter carrying a NASA payload of rendezvous sensors, orbital capture mechanisms, and an Earth entry vehicle (EEV). The high-level concept is that the landers will launch surface samples into Mars orbit, and the orbiter will retrieve the samples in orbit and then carry them back to Earth. The first element to depart for Mars will be one of the two landers. Currently, it is proposed that an intermediate class launch vehicle, such as the Boeing Delta 3 or Lockheed Martin Atlas 3A, will launch this 1800-kg lander from Cape Canaveral during the May 2003 opportunity. The lander will utilize a Type-1 transfer trajectory with an arrival at Mars in mid-December 2003. Landing will be aided by precision approach navigation and a guided hypersonic entry to achieve a touchdown accuracy of 10 km or better. Although the exact landing site has not yet been determined, it is estimated that lander resource constraints will limit the site to between 15 degrees north and south latitudes. Following touchdown, the lander will deploy a six-wheeled, 60-kg rover carrying an extensive suite of instruments designed to aid in the analysis of the local terrain and collection of core samples from selected rocks. The surface mission is currently designed around a concept called the surface traverse. Each traverse will involve the rover exploring a selected area of terrain up to 100 meters from the lander, the collection of rock core samples, and the delivery of the samples from the traverse back to a sample canister on the lander. Planning estimates indicate that up to three traverses may be possible during the expected 90-sol lifetime of the lander. The canister that will receive the samples from the rover will be attached to the top stage of a small solid-fueled rocket mounted to the deck of the lander. This rocket is called the Mars Ascent Vehicle (MAV) and consists of three stages weighing a total of about 140 kg. After the conclusion of the surface mission, the MAV will lift-off and insert the sample canister into a near-circular orbit with an altitude of about 600 km and inclination of 45 degrees. The sample canister will wait in this orbit until it is retrieved by the orbiter sometime in early 2007. In August 2005, the second lander and a CNES-provided orbiter weighing 2700 kg will depart for Mars. Currently, it is proposed that a single Ariane 5 provided by CNES will launch both of these two elements onto a Type-2 transfer trajectory. Although the orbiter and lander will be launched together, they will separate shortly after injection and will fly to Mars as two independent spacecraft. However, both spacecraft will perform a maneuver between 10 and 15 days after launch so that their arrival times at Mars differ by between 12 and 24 hours. This scheme will reduce the operational complexity at the encounter date. A set of four 60-kg surface probes will ride piggyback on the orbiter to Mars. These CNES-provided probes are called Netlanders and will serve as surface stations for scientific investigations independent of the Mars Sample Return goals. Starting approximately one month prior to arrival at Mars, the orbiter will begin to release the Netlanders one at a time. Each release cycle will take several days, and will include time for precision navigation to execute one or two maneuvers that will target the Netlanders to their proper landing site. All four deployment cycles will be completed prior to 10 days before arrival. Both the orbiter and lander will arrive in late-July 2006. Upon arrival, the lander will perform a precision landing and surface mission similar in concept to the one that was executed during the 2003 opportunity. Although the landing site for the 2005 opportunity has not been selected, it is expected to be different from the 2003 site to enhance the diversity of the collected samples. The orbiter's arrival at Mars will be highlighted by the first use of aerocapture to insert a spacecraft into a capture orbit around another planet. The choice of aerocapture, as opposed to a propulsive orbit insertion, was considered mission enabling due to a reduction of over 2000 m/s in mission AV. Aerocapture will be targeted to produce a 250 km x 1400 km capture orbit with an inclination of 45 degrees. Current analysis indicates that achieving this goal will require approximately six minutes of flight deep in the atmosphere with a targeted periapsis of approach of about 43 km. After factoring into account the penalty for carrying a heat shield to survive aerocapture, the net savings compared to a propulsive orbital insertion amounts to several hundred kilograms.

Lee, Wayne J.↗

NEA Multi-Chamber Sample Return Container with Hermetic Sealing

A sample return container is being developed by Honeybee Robotics to receive samples from a derivative of the Champollion/ST4 Sample Acquisition and Transfer Mechanism or other samplers such as the 'Touch and Go' Surface Sampler (TGSS), and then hermetically seal the samples for a sample return mission. The container is enclosed in a phase change material (PCM) chamber to prevent phase change during return and re-entry to earth. This container is designed to operate passively with no motors and actuators. Using the rotation axis of the TGSS sampler for interfacing, transferring and sealing samples, the container consumes no electrical power and therefore minimizes sample temperature change. The circular container houses multiple isolated canisters, which will be sealed individually for samples acquired from different sites or depths. The TGSS based sampler indexes each canister to the sample transfer position, below the index interface for sample transfer. After sample transfer is completed, the sampler indexes a seal carrier, which lines up seals with the openings of the canisters. The sampler moves to the sealing interface and seals the sample canisters one by one. The sealing interface can be designed to work with C-seals, knife edge seals and cup seals. This sample return container is being developed by Honeybee Robotics in collaboration with the JPL Exploration Technology program. A breadboard system of the sample return container has been recently completed and tested. Additional information is contained in the original extended abstract.

Rafeek, Shaheed↗

A Sample Return Container with Hermetic Seal

A sample return container is being developed by Honeybee Robotics to receive samples from a derivative of the Champollion/ST4 Sample Acquisition and Transfer Mechanism or other samplers and then hermetically seal samples for a sample return mission. The container is enclosed in a phase change material (PCM) chamber to prevent phase change during return and re-entry to earth. This container is designed to operate passively with no motors and actuators. Using the sampler's featured drill tip for interfacing, transfer-ring and sealing samples, the container consumes no electrical power and therefore minimizes sample temperature change. The circular container houses a few isolated canisters, which will be sealed individually for samples acquired from different sites or depths. The drill based sampler indexes each canister to the sample transfer position, below the index interface for sample transfer. After sample transfer is completed, the sampler indexes a seal carrier, which lines up seals with the openings of the canisters. The sampler moves to the sealing interface and seals the sample canisters one by one. The sealing interface can be designed to work with C-seals, knife edge seals and cup seals. Again, the sampler provides all sealing actuation. This sample return container and co-engineered sample acquisition system are being developed by Honeybee Robotics in collaboration with the JPL Exploration Technology program.

Kin Yuen Kong↗

Device Acquires and Retains Rock or Ice Samples

The Rock Baller is a sample acquisition tool that improves sample retention. The basic elements of the Rock Baller are the tool rotation axis, the hub, the two jaws, and the cutting blades, which are located on each of the jaws. The entire device rotates about the tool rotation axis, which is aligned parallel to the nominal normal direction of the parent rock surface. Both jaws also rotate about the jaw axis, which is perpendicular to the tool rotation axis, at a rate much slower than the rotation about the tool rotation axis. This movement gradually closes the jaws into a nearly continuous hemispherical shell that encloses the sample as it is cut from the parent rock. When required the jaws are opened to release the sample. The hemispherical cutting method eliminates the sample retention problems associated with existing sample acquisition methods that employ conventional cylindrical cutting. The resulting samples are hemispherical, or nearly hemispherical, and as a result the aspect ratio (sample depth relative to sample radius) is essentially fixed. This fixed sample aspect ratio may be considered a drawback of the Rock Baller method, as samples with a higher aspect ratio (more depth, less width) may be considered more scientifically valuable because such samples would allow for a broader inspection of the geological record. This aspect ratio issue can be ameliorated if the Rock Baller is paired with a device similar to the Rock Abrasion Tool (RAT) used on the Mars Exploration Rovers. The RAT could be used to first grind into the surface of the parent rock, after which the Rock Baller would extract a sample from a depth inside the rock that would not have been possible without first using the RAT. Other potential applications for this technology include medical applications such as the removal of tissue samples or tumors from the body, particularly during endoscopic, laparoscopic, or thoracoscopic surgeries.

Giersch, Louis R.↗