Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single point correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Simple Laser Communications Terminal for Downlink from Earth Orbit at Rates Exceeding 10 Gb/s

A compact, low-cost laser communications transceiver was prototyped for downlinking data at 10 Gb/s from Earth-orbiting spacecraft. The design can be implemented using flight-grade parts. With emphasis on simplicity, compactness, and light weight of the flight transceiver, the reduced-complexity design and development approach involves: 1. A high-bandwidth coarse wavelength division multiplexed (CWDM) (4 2.5 or 10-Gb/s data-rate) downlink transmitter. To simplify the system, emphasis is on the downlink. Optical uplink data rate is modest (due to existing and adequate RF uplink capability). 2. Highly simplified and compact 5-cm diameter clear aperture optics assembly is configured to single transmit and receive aperture laser signals. About 2 W of 4-channel multiplexed (1,540 to 1,555 nm) optically amplified laser power is coupled to the optical assembly through a fiber optic cable. It contains a highly compact, precision-pointing capability two-axis gimbal assembly to coarse point the optics assembly. A fast steering mirror, built into the optical path of the optical assembly, is used to remove residual pointing disturbances from the gimbal. Acquisition, pointing, and tracking are assisted by a beacon laser transmitted from the ground and received by the optical assembly, which will allow transmission of a laser beam. 3. Shifting the link burden to the ground by relying on direct detection optical receivers retrofitted to 1-m-diameter ground telescopes. 4. Favored mass and volume reduction over power-consumption reduction. The two major variables that are available include laser transmit power at either end of the link, and telescope aperture diameter at each end of the link. Increased laser power is traded for smaller-aperture diameters. 5. Use of commercially available spacequalified or qualifiable components with traceability to flight qualification (i.e., a flight-qualified version is commercially available). An example is use of Telecordia-qualified fiber optic communication components including active components (lasers, amplifiers, photodetectors) that, except for vacuum and radiation, meet most of the qualifications required for space. 6. Use of CWDM technique at the flight transmitter for operation at four channels (each at 2.5 Gb/s or a total of 10 Gb/s data rate). Applying this technique allows utilization of larger active area photodetectors at the ground station. This minimizes atmospheric scintillation/turbulence induced losses on the received beam at the ground terminal. 7. Use of forward-error-correction and deep-interleaver codes to minimize atmospheric turbulence effects on the downlink beam. Target mass and power consumption for the flight data transmitter system is less than 10 kg and approximately 60 W for the 400-km orbit (900-km slant range), and 12 kg and 120 W for the 2,000-km orbit (6,000-km slant range). The higher mass and power for the latter are the result of employing a higher-power laser only.

Kovalik, Joseph M.↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear-level effective theory of 𝜇→𝑒 conversion: Formalism and applications

Over the next decade new 𝜇→𝑒 conversion searches at Fermilab (Mu2e) and J-PARC (COMET, DeeMe) are expected to advance limits on charged lepton flavor violation (CLFV) by more than four orders of magnitude. Here, by considering the consequence of 𝑃 and 𝐶⁢𝑃 on elastic 𝜇→𝑒 conversion and the structure of possible charge and current densities, we show that rates are governed by six nuclear responses and a single scale, 𝑞/𝑚 𝑁 , where 𝑞 ≈ 𝑚 𝜇 is the momentum transferred from the leptons to the nucleus. To relate this result to microscopic formulations of CLFV, we construct in nonrelativistic effective theory (NRET) the CLFV nucleon-level interaction, pointing out the relevance of the dimensionless scales 𝑦=($^{𝑞⁢𝑏}_2$) 2 ⁢ > |$\overrightarrow{𝑣}_N$⁢|>|$\overrightarrow{𝑣}_μ$⁢|>|$\overrightarrow{𝑣}_T$| , where 𝑏 is the nuclear size, $\overrightarrow{𝑣}_N$ and $\overrightarrow{𝑣}_μ$ are the nucleon and muon intrinsic velocities, and $\overrightarrow{𝑣}_T$ is the target recoil velocity. We discuss previous work, noting the lack of a systematic treatment of the various small parameters. Because the parameter 𝑦 is not small, a proper calculation of 𝜇→𝑒 conversion requires a full multipole expansion of the nuclear response functions, an apparently daunting task with Coulomb-distorted electron partial waves. We demonstrate that the multipole expansion can be carried out to high precision by introducing a simplifying local momentum 𝑞 eff for the electron. Previous work has been limited to simple charge or spin interactions, thereby treating the nucleus effectively as a point particle. We show that such formulations are not compatible with the general form of the 𝜇→𝑒 conversion rate, failing to generate three of the six allowed nuclear response functions. The inclusion of the nucleon velocity $\overrightarrow{𝑣}_N$ yields an NRET with 16 operators and a rate of the general form. Consequently, in the current discovery era for CLFV, it provides the most sensible starting point for experimental analysis, defining what can and cannot be determined about CLFV from the highly exclusive process of 𝜇→𝑒 conversion. Finally, we expand the NRET operator basis to account for the effects of $\overrightarrow{𝑣}_μ$, associated with the muon's lower component, generating corrections to the CLFV coefficients of the point-nucleus response functions. Using advanced shell-model methods, we compute 𝜇→𝑒 conversion rates for a series of experimental targets, deriving bounds on the coefficients of the CLFV operators. These calculations are the first to include a general basis of CLFV operators, full evaluation of the associated nuclear response functions, and an accurate treatment of electron and muon Coulomb effects. We discuss target selection as an experimental “knob” that can be turned to probe the microscopic origins of CLFV. We describe two types of coherence that enhance certain CLFV operators and selection rules that blind elastic 𝜇→𝑒 conversion to others. We discuss the matching of the NRET onto higher level effective field theories, such as those constructed at the light quark level, noting opportunities to build on existing work in direct detection of dark matter. We discuss the relation of 𝜇→𝑒 conversion to 𝜇→𝑒+𝛾 and 𝜇→3⁢𝑒, showing how MEG II and Mu3e results will complement those of Mu2e and COMET. Finally we describe a accompanying script—in Mathematica and Python versions—that can be used to compute 𝜇→𝑒 conversion rates in various nuclear targets for the full set of NRET operators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques

Purpose: To commission a small-field biological irradiator, the XRad225Cx from Precision x-Ray, Inc., for research use. The system produces a 225 kVp x-ray beam and is equipped with collimating cones that produce both square and circular radiation fields ranging in size from 1 to 40 mm. This work incorporates point, 2D, and 3D measurements to determine output factors (OF), percent-depth-dose (PDD) and dose profiles at multiple depths. Methods: Three independent dosimetry systems were used: ion-chambers (a farmer chamber and a micro-ionisation chamber), 2D EBT2 radiochromic film, and a novel 3D dosimetry system (DLOS/PRESAGE registered ). Reference point dose rates and output factors were determined from in-air ionization chamber measurements for fields down to {approx}13 mm using the formalism of TG61. PDD, profiles, and output factors at three separate depths (0, 0.5, and 2 cm), were determined for all field sizes from EBT2 film measurements in solid water. Several film PDD curves required a scaling correction, reflecting the challenge of accurate film alignment in very small fields. PDDs, profiles, and output factors were also determined with the 3D DLOS/PRESAGE registered system which generated isotropic 0.2 mm data, in scan times of 20 min. Results: Surface output factors determined by ion-chamber were observed to gradually drop by {approx}9% when the field size was reduced from 40 to 13 mm. More dramatic drops were observed for the smallest fields as determined by EBT{approx}18% and {approx}42% for the 2.5 mm and 1 mm fields, respectively. PRESAGE registered and film output factors agreed well for fields <20 mm (where 3D data were available) with mean deviation of 2.2% (range 1%-4%). PDD values at 2 cm depth varied from {approx}72% for the 40 mm field, down to {approx}55% for the 1 mm field. EBT and PRESAGE registered PDDs agreed within {approx}3% in the typical therapy region (1-4 cm). At deeper depths the EBT curves were slightly steeper (2.5% at 5 cm). These results indicate good overall consistency between ion-chamber, EBT2 and PRESAGE registered measured OFs, PDDs, and profiles. Conclusions: The combination of independent 2D and 3D measurements was found to be valuable to ensure accurate and comprehensive commissioning. Film measurements were time consuming and challenging due to the difficulty of film alignment in small fields. PRESAGE registered 3D measurements were comprehensive and efficient, because alignment errors are negligible, and all parameters for multiple fields could be obtained from a single dosimeter and scan. However, achieving accurate superficial data (within 4 mm) is not yet feasible due to optical surface artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

Fluid Management of and Flame Spread Across Liquid Pools

The goal of our research on flame spread across pools of liquid fuel remains the quantitative identification of the mechanisms that control the rate and nature of flame spread when the initial temperature of the liquid pool is below the fuel's flash point temperature. As described in, four microgravity (mu-g) sounding rocket flights examined the effect of forced opposed airflow over a 2.5 cm deep x 2 cm wide x 30 cm long pool of 1-butanol. Among many unexpected findings, it was observed that the flame spread is much slower and steadier than in 1g where flame spread has a pulsating character. Our numerical model, restricted to two dimensions, had predicted faster, pulsating flame spread in mu-g. In a test designed to achieve a more 2-D experiment, our investigation of a shallow, wide pool (2 mm deep x 78 mm wide x 30 cm long) was unsuccessful in mu-g, due to an unexpectedly long time required to fill the tray. As such, the most recent Spread Across Liquids (SAL) sounding rocket experiment had two principal objectives: 1) determine if pulsating flame spread in deep fuel trays would occur under the conditions that a state-of-the-art computational combustion code and short-duration drop tower tests predict; and 2) determine if a long, rectangular, shallow fuel tray could achieve a visibly flat liquid surface across the whole tray without spillage in the mu-g time allotted. If the second objective was met, the shallow tray was to be ignited to determine the nature of flame spread in mu-g for this geometry. For the first time in the experiment series, two fuel trays - one deep (30 cm long x 2 cm wide x 25 mm deep) and one shallow (same length and width, but 2 mm deep)-- were flown. By doing two independent experiments in a single flight, a significant cost savings was realized. In parallel, the computational objective was to modify the code to improve agreement with earlier results. This last objective was achieved by modifying the fuel mass diffusivity and adding a parameter to correct for radiative and lateral heat loss.

Ross, H. D.↗

Effective point of measurement of thimble ion chambers in megavoltage photon beams

Purpose: Determine the effective point of measurement (EPOM) of 12 thimble ion chambers, including miniature chambers and three models widely used for clinical reference dosimetry. The EPOM is the point at which the measured dose would arise in the measurement medium in the absence of the probe: For cylindrical chambers, it is shifted upstream relative to the central axis of the chamber. Although current dosimetry protocols prescribe a blanket upstream EPOM shift of 0.6r, with r as the chamber cavity radius, it has been shown in recent years that the EPOM does, in fact, depend on every detail of the chamber design and on the beam characteristics. In the wake of this finding, the authors undertake a comprehensive study of the EPOM for a series of chambers in water. Methods: This work relies on EGSnrc Monte Carlo calculations for the central axis depth dose in a water phantom and in ion chambers. They use a full Elekta Precise linac treatment head simulation to generate realistic photon beams with nominal energies of 6 and 25 MV and fields sizes of 10x10 and 40x40 cm{sup 2}. The correct EPOM shift for the 12 ion chambers, modeled in realistic detail, is taken as the one minimizing the deviation of the ratio between the dose to water and the dose to the gas of the chamber cavity, according to a method proposed and validated in previous work. Results: The analysis reveals that the actual EPOM shift is significantly smaller than the recommended value in current dosimetry protocols, by up to 25% for reference-class chambers and 80% for miniature chambers. The location of the EPOM also depends on the characteristics of the incident beam and varies in a well-defined way with the cavity length, the central electrode radius, and the thimble wall thickness. Conclusions: The authors confirm that an upstream EPOM shift of 0.6r is too large for thimble ion chambers in high energy photon beams. Proper values for the EPOM shift could be tabulated per beam and per chamber, but they envisage that a single shift for all practical beams may prove sufficient. Moreover, the systematic dependence on chamber characteristics provides evidence that a universal parametrization in terms of a few design parameters is conceivable and has implication for the calculation of chamber correction factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Health Management and Prognostics for Electric Aircraft Powertrain

W and c Any air borne vehicle needs incorporating safety as key parameter of measure, and inclusion of autonomy raises the critical need for safety under autonomous operations. Management of faults and component degradation is key as complexity in autonomous operations grow over the period of time. Therefore, in addition to basic operational requirements, an autonomous electric vehicle should be able to make accurate estimates of its current system health and take the correct decisions to complete its mission successfully. Real-time safety and state-awareness tools are therefore essential for the vehicle to be able to reach its destination in a safe and successful manner. The need for safety assurance and health management capabilities is particularly relevant for aircraft electric propulsion systems, which are relatively new and with limited historical to learn. They are critical systems requiring high power density along with reliability, resilience, efficient management of weight, and operational costs. A model- based fault diagnosis and prognostics approach of complex critical systems can successfully accomplish the safety and state awareness goal for such electric propulsion systems, enabling autonomous decision making capability for safe and efficient operation. To identify critical components in the system a Qualitative Bayesian approach using FMECA is implemented. This requires the assessment of some quantities representing the state of the electric unmanned aerial systems (e-UAS), as well as look-ahead forecasts of such states during the entire flight, presented in form of safety metrics (SM). In-service data and performance data gathered from degraded components sup- ports diagnostic and prognostic methods for these systems, but this data can be difficult to obtain as weight and packaging restrictions reduce redundancy and instrumentation on-board the vehicle. Therefore, an model-based framework should be capable or operating with limited data. In addition to data scarcity, the variability of such complex critical systems re- quires the model-based framework to reason in the presence of uncertainty, such as sensor noise, and modeling imperfections. Quantification of errors and uncertainties in the measured states and quantities is therefore a fundamental step for a precise estimation of such SMs; un-modeled uncertainty may result in erroneous state assessment and un- reliable predictions of future states of e-UAVs. Typical, centralized model-based schemes suffer from inherent disadvantages such as computational complexity, single point of failure, and scalability issues, and therefore may fail in such a complex scenario. This paper presents a methodology for developing a system level diagnostics and prognostics approach using a Qualitative Bayesian FMECA approach along with a formal uncertainty management framework for an e-UAS. In this work we demonstrate the efficacy of the framework to predict effects of sub-system level degradation on vehicle operation incorporating uncertainty management to predict future behavior under different operating conditions.

Kulkarni, Chetan↗

Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images

Purpose: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry. Methods: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5°/voxels, keeping ≤5% difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed. Results: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (−15.50 ± 5.59)% to (−2.12 ± 1.05)% and (−7.28 ± 2.30)% to (−0.23 ± 0.71)% for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79% to 22.70% for liver and 26.00% to 39.70% for spleen with different segmentation methods. Conclusions: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.

60 APPLIED LIFE SCIENCES↗

An Automated Microfluidic Assay for Photonic Crystal Enhanced Detection and Analysis of an Antiviral Antibody Cancer Biomarker in Serum

Here, we report on the implementation of an automated platform for detecting the presence of an antibody biomarker for human papillomavirus-associated oropharyngeal cancer from a single droplet of serum, in which a nanostructured photonic crystal surface is used to amplify the output of a fluorescence-linked immunosorbent assay. The platform is comprised of a microfluidic cartridge with integrated photonic crystal chips that interfaces with an assay instrument that automates the introduction of reagents, wash steps, and surface drying. Upon assay completion, the cartridge interfaces with a custom laser-scanning instrument that couples light into the photonic crystal at the optimal resonance condition for fluorescence enhancement. The instrument is used to measure the fluorescence intensity values of microarray spots corresponding to the biomarkers of interest, in addition to several experimental controls that verify correct functioning of the assay protocol. In this work, we report both dose-response characterization of the system using anti-E7 antibody introduced at known concentrations into serum and characterization of a set of clinical samples from which results were compared with a conventional enzyme-linked immunosorbent assay (ELISA) performed in microplate format. Finally, the demonstrated capability represents a simple, rapid, automated, and high-sensitivity method for multiplexed detection of protein biomarkers from a low-volume test sample.

59 BASIC BIOLOGICAL SCIENCES↗

DOE-RCT-0003641 Final Technical Report

This program studied novel concepts for an Axial Flux Reluctance Machine to capture energy from marine hydrokinetic sources and compared their attributes to a Radial Flux Reluctance Machine which was designed under a prior Department of Energy program for the same application. Detailed electromagnetic and mechanical analyses were performed to determine the validity of the concept and to provide a direct comparison with the existing conventional Radial Flux Switched Reluctance Machine designed during the Advanced Wave Energy Conversion Project, DE-EE0003641. The alternate design changed the machine topology so that the flux that is switched flows axially rather than radially and the poles themselves are long radially, as opposed to the radial flux machine that has pole pieces that are long axially. It appeared possible to build an axial flux machine that should be considerably more compact than the radial machine. In an “apples to apples” comparison, the same rules with regard to generating magnetic force and the fundamental limitations of flux density hold, so that at the heart of the machine the same torque equations hold. The differences are in the mechanical configuration that limits or enhances the change of permeance with rotor position, in the amount of permeable iron required to channel the flux via the pole pieces to the air-gaps, and in the sizing and complexity of the electrical winding. Accordingly it was anticipated that the magnetic component weight would be similar but that better use of space would result in a shorter machine with accompanying reduction in housing and support structure. For the comparison the pole count was kept the same at 28 though it was also expected that the radial tapering of the slots between pole pieces would permit a higher pole count machine, enabling the generation of greater power at a given speed in some future design. The baseline Radial Flux Machine design was established during the previous DOE program. Its characteristics were tabulated for use in comparing to the Axial Flux Machine. Three basic conceptual designs for the Axial Flux Machine were considered: (1) a machine with a single coil at the inner diameter of the machine, (2) a machine with a single coil at the outside diameter of the machine, and (3) a machine with a coil around each tooth. Slight variations of these basic configurations were considered during the study. Analysis was performed on these configurations to determine the best candidate design to advance to preliminary design, based on size, weight, performance, cost and manufacturability. The configuration selected as the most promising was the multi-pole machine with a coil around each tooth. This configuration provided the least complexity with respect to the mechanical configuration and manufacturing, which would yield the highest reliability and lowest cost machine of the three options. A preliminary design was performed on this selected configuration. For this first ever axial design of the multi rotor configuration the 'apples to apples' comparison was based on using the same length of rotor pole as the axial length of rotor pole in the radial machine and making the mean radius of the rotor in the axial machine the same as the air gap radius in the radial machine. The tooth to slot ratio at the mean radius of the axial machine was the same as the tooth to slot ratio of the radial machine. The comparison between the original radial flux machine and the new axial flux machine indicates that for the same torque, the axial flux machine diameter will be 27% greater, but it will have 30% of the length, and 76% of the weight. Based on these results, it is concluded that an axial flux reluctance machine presents a viable option for large generators to be used for the capture of wave energy. In the analysis of Task 4, below, it is pointed out that our selection of dimensional similarity for the 'apples to apples' comparison did not produce an optimum axial flux design. There is torque capability to spare, implying we could reduce the magnetic structure, but the winding area, constrained by the pole separation at the inner pole radius has a higher resistance than desirable, implying we need more room for copper. The recommendation is to proceed via one cycle of optimization and review to correct this unbalance and then proceed to a detailed design phase to produce manufacturing drawings, followed by the construction of a prototype to test the performance of the machine against predicted results.

16 TIDAL AND WAVE POWER↗

Discovery of ferromagnetism with large magnetic anisotropy in ZrMnP and HfMnP

ZrMnP and HfMnP single crystals are grown by a self-flux growth technique, and structural as well as temperature dependent magnetic and transport properties are studied. Both compounds have an orthorhombic crystal structure. ZrMnP and HfMnP are ferromagnetic with Curie temperatures around 370 K and 320 K, respectively. The spontaneous magnetizations of ZrMnP and HfMnP are determined to be 1.9 μ{sub B}/f.u. and 2.1 μ{sub B}/f.u., respectively, at 50 K. The magnetocaloric effect of ZrMnP in terms of entropy change (ΔS) is estimated to be −6.7 kJ m{sup −3} K{sup −1} around 369 K. The easy axis of magnetization is [100] for both compounds, with a small anisotropy relative to the [010] axis. At 50 K, the anisotropy field along the [001] axis is ∼4.6 T for ZrMnP and ∼10 T for HfMnP. Such large magnetic anisotropy is remarkable considering the absence of rare-earth elements in these compounds. The first principle calculation correctly predicts the magnetization and hard axis orientation for both compounds, and predicts the experimental HfMnP anisotropy field within 25%. More importantly, our calculations suggest that the large magnetic anisotropy comes primarily from the Mn atoms, suggesting that similarly large anisotropies may be found in other 3d transition metal compounds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Operating Small Sat Swarms as a Single Entity: Introducing SODA

Swarm concepts are a growing topic of interest in the small satellite community. Compared to a small satellite constellation, a swarm has the distinction of being multiple spacecraft in close proximity, in approximately the same orbit. Furthermore, we envision swarms to have capabilities for cross-link communication and station-keeping. Of particular interest is a means to maintain operator-specified geometry, alignment, and/or separation.From NASA's decadal survey, it is clear that simultaneous measurements from a 3D volume of space are desired for a variety of Earth scientific studies. As this mission concept is ultimately extended to deep space, some degree of local control for the swarm to self-correct its configuration is required. We claim that the practicality of ground commanding each individual satellite in the swarm is simply not a feasible concept of operations. In other words, the current state-of-practice does not scale to very large swarms (e.g. 100 spacecraft or more) without becoming cost prohibitive. To contain the operations costs and complexity, a new approach is required: the swarm must be operated as a unit, responding to high-level specifications for relative position and velocity.The Mission Design Division at NASA Ames Research Center is looking to the near future for opportunities to develop satellite swarm technology. As part of this effort, we are developing SODA (Swarm Orbital Dynamics Advisor), a tool that provides the orbital maneuvers required to achieve a desired type of relative swarm motion. The purpose of SODA is two-fold. First, it encompasses the algorithms and orbital dynamics model to enable the desired relative motion of the swarm satellites. The process starts with the user specifying the properties of a swarm configuration. This could be as simple as varying in-track spacing of the swarm in one orbit, or as complex as maintaining a specified 3D geometrical orientation. We presume that science objectives will drive this choice. Given these inputs, the tool provides the most efficient maneuver(s) to achieve the objective.Second, SODA provides a variety of visualization tools. We acknowledge that the relationship between a desired relative motion amongst the swarm, and the corresponding orbital parameters for each individual satellite may not be immediately apparent for ground controllers and mission planners. The purpose of SODA's visualization tools is to illustrate this concept clearly with a variety of graphics and animations. After computing the optimal orbital maneuvers to modify the swarm, these results are simulated to demonstrate successful swarm control.Our emphasis in this paper is on the importance of relating the desired motion of the swarm satellites relative to one another with the required orbital element changes. One cannot joystick a drifting swarm satellite back into position; the underlying orbital mechanics dictate the most efficient recovery maneuvers. To illustrate this point, results from several case study simulations are presented. We conclude with our forward work for ongoing SODA development and potential science applications.

small satellites↗

Leveraging VIPER Geotechnical and Mobility Insights for Endurance Rover and Traverse Development

A new generation of lunar surface rover exploration is rapidly approaching. This is evidenced by the rise of commercially developed rovers from private companies (e.g., Lunar Outpost’s MAPP) and government agencies, like NASA’s Volatiles Investigating Polar Exploration Rover (VIPER), the Lunar Terrain Vehicle (LTV), and the Endurance/Intrepid rover concepts, and the INSPIRE mission concept. The drive distance requirements for off-world vehicles are also rapidly increasing. For example, LTV driving requirements dictate a 20 km range on a single battery charge, with an overall lifetime requirement of 13,000 km over a minimum 10-year service life. Similarly, NASA's Endurance-A mission concept requires a 2000 km vehicle traverse distance, which is nearly 50 times further than the USSR's Lunokhod 2, the longest lunar rover mission to date. Previous planetary surface missions on the Moon and Mars have revealed harsh mobility conditions: aggressive rocky terrains on Mars severely damaged the Curiosity rover’s wheels, soft lunar regolith caused the Lunokhod 2 rover to sink and NASA’s Apollo 15 LRV (Lunar Roving Vehicle) spun out due to poor traction, which required manual correction. This demonstrates that mobility challenges like wheel degradation and soft soil driving performance must be accounted for in a mission’s design phase to meet increasingly aggressive mission durations and mobility goals. The success of these long duration missions requires highly reliable and durable mobility platforms in conjunction with a more developed understanding of the geotechnical properties of the lunar surface. The VIPER mission is uniquely posed to inform future missions about mobility performance, wheel durability, and lunar surface soil mechanics of sunlit and shadowed regions through use of data streams that already exist for other mission purposes. VIPER’s mission to the lunar south pole will provide a new perspective into off-world mobility challenges including traversal into permanently shadowed regions. Mobility data from VIPER’s mission will represent a first glimpse into the surface mobility challenges of the lunar South Pole. Utilization of VIPER’s existing capabilities including cameras, inertial measurement unit (IMU) data, motor currents/torque, drill data, and the rover’s suspension state and kinematics provide the opportunity to determine potentially useful information for future rover and traverse designs, as well as on-Earth testing practices. Data products collected during VIPER’s mission could inform design considerations for the Endurance rover much earlier than NASA’s standard “lessons learned” approach as VIPER has a highly tactical mission operations structure. This work outlines the specific links between possible data products from the VIPER mission and their potential impact on the Endurance/Intrepid mission concepts in their early design phases. From VIPER, we will also gain insights for future development of onboard mobility software as VIPER is a way-point driven rover which requires more constant human operation on Earth than some other rover missions (non-lunar surface). Primary VIPER data products and insights of interest include wheel sinkage, wheel slip, wheel degradation, surface soil shear strength, and terrain slope estimation. VIPER data products will be made available via the Planetary Data System’s Geosciences and Cartography and Imaging Sciences nodes, conforming to the PDS4 standard.

mobility↗

Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance

To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatment sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ionospheric calibration for single frequency altimeter measurements

This study is a preliminary analysis of the effectiveness (in terms of altimeter calibration accuracy) of various ionosphere models and the Global Positioning System (GPS) to calibrate single frequency altimeter height measurements for ionospheric path delay. In particular, the research focused on ingesting GPS Total Electron Content (TEC) data into the physical Parameterized Real-Time Ionospheric Specification Model (PRISM), which estimates the composition of the ionosphere using independent empirical and physical models and has the capability of adjusting to additional ionospheric measurements. Two types of GPS data were used to adjust the PRISM model: GPS receiver station data mapped from line-of-sight observations to the vertical at the point of interest and a grid map (generated at the Jet Propulsion Laboratory) of GPS derived TEC in a sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by the International Reference Ionosphere (IRI-90), a climatological (monthly mean) model of the ionosphere, were compared to TOPEX dual-frequency TEC measurements (considered as truth) for a number of TOPEX sub-satellite tracks. For a 13.6 GHz altimeter, a Total Electron Content (TEC) of 1 TECU 10(exp 16) electrons/sq m corresponds to approximately 0.218 centimeters of range delay. A maximum expected TEC (at solar maximum or during solar storms) of 10(exp 18) electrons/sq m will create 22 centimeters of range delay. Compared with the TOPEX data, the PRISM predictions were generally accurate within the TECU when the sub-satellite track of interest passed within 300 to 400 km of the GPS TEC data or when the track passed through a night-time ionosphere. If neither was the case, in particular if the track passed through a local noon ionosphere, the PRISM values differed by more than 10 TECU and by as much as 40 TECU. The IRI-90 model, with no current ability to unseat GPS data, predicted TEC to a slightly higher error of 12 TECU. The performance of PRISM is very promising for predicting TEC and will prove useful for calibrating single frequency altimeter height measurements for ionospheric path delay. When adjusted to the GPS line-of-sight data the PRISM URSI empirical model predicted TEC over a day's period to within a global error of 8.60 TECU rms during a nighttime ionosphere and 9.74 TECU rms during the day. When adjusted to the GPS derived TEC grid, the PRISM parametrized model predicted TEC to within an error of 8.47 TECU rms for a nighttime ionosphere and 12.83 TECU rms during the day. However, the grid cannot be considered globally due to the lack of sufficient numbers of GPS stations and large latitude gaps in GPS data. It is the opinion of the authors that using the PRISM model and adjusting to the global sun-fixed TEC grid regenerated with a localized weighted interpolation offers the best possibility of meeting the 10 TECU global rms (or 2 cm at 13.6 GHz) ionosphere range correction accuracy requirement of TOPEX/Poseidon and should be the subject of further study. However, it is clear that the anticipated requirement of 34 TECU global rms for TOPEX/Poseidon Follow-On (corresponding to the TOPEX/Poseidon performance) can not be met with any realizable combination of existing models and data assimilation schemes.

Schreiner, William S.↗

Testing Nesting DXTRAN Spheres for Neutron Transport in Air

The deterministic transport sphere (DXTRAN sphere) is a technology that can be utilized in MCNP for improving sampling in the vicinity of a particular geometry, when the solid angle, between the source and particular geometry, is small. At a collision event, a DXTRAN particle is created and deterministically transported to the DXTRAN sphere, while the colliding particle (NONDXTRAN particle) continues transporting as if no DXTRAN event had occurred. Weight is balanced by killing the NONDXTRAN particle when traversing the DXTRAN sphere. If set up correctly, the DXTRAN particle placed on the DXTRAN sphere has a high probability of interacting with the geometry within the DXTRAN sphere. The Central Limit Theorem (CLT) states that the estimated mean approaches a normal distribution with known variance as the number of random samples grows sufficiently large. In reality the variance is seldom known and therefore must be estimated. In a Monte Carlo calculation, one must determine when the number of random samples is sufficiently large for the CLT to be satisfied. For the CLT to be satisfied, the first two moments (mean and variance) must exist. The second moment, the variance of a normal distribution is estimated. The slope test, which uses the largest 201 history scores of each tally fluctuation chart (TFC) bin fit to a Pareto function, is used to determine if the largest history scores decrease faster than 1/x{sup 3}. If the slope is less than 3, then enough histories have not yet been sampled such to meet the second moment existence requirement of the CLT. Usually, a slope of less than 3 indicates that the effects of high weight scores have not been satisfactorily sampled; such a consequence can also be manifested in examining trends in the 4. moment, the variance of the variance (VOV). For example, when examining the TFC, if the VOV is monotonically decreasing for a few sets of histories and then drastically increases for the next set of histories, chances are a rare high weight score, significantly greater than the average score, was encountered. As a result of the 1/R{sup 2} term, a point detector can achieve an extremely high weight, much greater than the average, as the distance from collision to point detector approaches zero. To remedy this difficulty, a 'radius of exclusion' is applied, where within the radius of exclusion 'the point detector estimate is assumed to be the average flux uniformly distributed'. A DXTRAN sphere can suffer from the same weight fluctuation as collisions in the vicinity of the DXTRAN sphere produce much larger weights than collisions happening far from the DXTRAN sphere. If the rare large weight put on the DXTRAN sphere then scores in a tally, there will be a significant increase in the VOV and the slope may drop below 3. To compliment that analysis, here we utilize an air composition and density that varies as a function of altitude, detailing the trials and tribulations of attempting to pass the 10 statistical checks for a variety of single and nested DXTRAN sphere approaches. The objective here is to illuminate important considerations for radiation transport problems with small solid angles in a scatter medium of few mean free paths (MFPs)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗