Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sorbent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Ionic liquids for carbon capture

This article covers cutting-edge research in ionic liquid-based materials and their impact on carbon capture. Ionic liquids boast high thermal stability, low vapor pressure, and great tunability. They can be deployed as either sorbents or supported liquid membranes for carbon capture and other gas separations. Absorption of CO 2 in ionic liquids can be achieved via physisorption or chemisorption, depending on the strength of the interaction. For physisorption, both CO 2 -anion and cation–anion interactions are important factors in dictating CO 2 solubility. For chemisorption, the reactivity with CO 2 can be tuned by the basicity of the anion while the stability of the ionic liquid can be enhanced by controlling the cation. Marrying ionicity of ionic liquids with porosity leads to novel porous ionic liquids that feature unique properties for facilitating gas transport, while interfacing ionic liquids with microporous membranes allow the ions to gate the pores for selective gas transport. Further, composite materials of ionic liquids with crystalline materials such as metal–organic frameworks offer scalable heterogeneous interfaces to promote selectivity. Future opportunities include controlling the interaction with CO 2 and its transport at the charged or electrified interface with the ionic-liquid electric double layer, as well as combining CO 2 capture and conversion with ionic liquids.

36 MATERIALS SCIENCE↗

Intensified Flue Gas Desulfurization Water Treatment for Reuse, Solidification, and Discharge

The goal of this final project report is to summarize the work conducted on project DE-FE0031555. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UK CAER) (Recipient) developed a hybrid electrochemical-membrane technology for treating wet flue gas desulfurization (WFGD) blowdown from coal-fired power generation plants that (1) removes government-regulated species and total suspended solids (TSS) via electrocoagulation with solid/liquid separation to avoid further treatments by a biological method specifically for selenium, and (2) reduces total dissolved solids (TDS) in a nanofiltration unit to promote water recycle and reduce freshwater intake. Additional technological configurations were pursued, including (1) nanofiltration combined with zeolite dewatering for a near-zero liquid discharge (ZLD) scenario, and (2) polishing discharge from zeolite dewatering using capacitive deionization (CDI) with 90+% salt rejection to produce water with less than 100ppm TDS for more beneficial use. Project results verified that UK CAER’s hybrid approach addressed the complexities of WFGD blowdown with simplified unit operation at relatively low capital investment by demonstrating: (1) an effective in-situ generated solid sorbent material, green-rust (GR), that specifically removes regulated dissolved species in WFGD blowdown, including selenium, arsenic, and nitrates; (2) a low-cost, high flux nanofiltration treatment that removes both monovalent and divalent species at >80% rejection to adequately provide water recycle and extend the life of FGD equipment by mitigating chloride aided pitting corrosion mechanisms; and (3) a solidification and stabilization process using pozzolanic agents that retain regulated species and satisfy the Resource Conservation and Recovery Act (RCRA) leachate requirements. UK CAER proved electrocoagulation with GR to be an intensified solution for effluent limit guidelines (ELG), and based on preliminary techno-economic analysis (TEA), in comparison to DOE’s Case 1 for Biological Wastewater Treatment that had a purchased equipment cost (PEC) of $\$$5.26 million and a Total plant cost (TPC) of $\$$30.0 million, the EC process had a PEC of $\$$2.67 million and the TPC of $\$$17.0 million. While the electricity consumption for Case 1 was 53 kW, it was 110 kW for the EC process due to dissolving iron for a three-stage reaction design. However, electricity consumption for the EC process could be significantly reduced by adopting a counter-current reactor design for at least a 6-stage chemical reaction operation.

01 COAL, LIGNITE, AND PEAT↗

Effect of NO x and Water Variations on Iodine Loading of AgZ

Reprocessing of used nuclear fuel will result in the release of several volatile radionuclides that need to be removed from facility off-gas streams before their release to the environment. Iodine, one of these radionuclides, is expected to be primarily released in the dissolver off-gas stream as iodine (I 2 ) or methyl iodide (CH 3 I). Sorbents that target I 2 and CH 3 I removal from the DOG stream will need to adsorb iodine under elevated temperatures and in the presence of water vapor and nitrogen oxides (NO x ). Previous studies examining the adsorption of CH 3 I and I 2 in the presence of NO x gases by silver-exchanged mordenite (AgZ), a zeolite mineral considered for use in this application, have resulted in slightly inconsistent conclusions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Metal-Organic Framework Glasses as Rad Contaminant Sequesters and Nuclear Waste Forms

Remediation of Tc remains an unresolved problem at SRS and other DOE sites. The objective of this project was to develop novel metal organic framework (MOF) glasses for radioactive contaminant sequestration and stabilization from aqueous media. During FY20, we synthesized, characterized and evaluated additional cetyltrimethylcimmonium bromide (CTAB)-functionalized and F - , Cl - , I - , CF 3 SO 3 - exchanged MIL-101-Cr samples. MIL-10l-Cr-NO 3 -CTAB was demonstrated to have high ReO 4 - removed capacity (139 mg/g sorbent) from artificial groundwater (AGW). Re chemical specicition and binding mechanism on MIL-101-CTAB were also studied by synchrotron X-ray absorption spectroscopy. ReO 4 - was demonstrated as being in the pore structure with slightly larger Re-O bond distances than those in NciReO 4 and binding with the positively charged sites of CTAB. In addition, a new Ni-TIPA MOF was demonstrated to be very stable, selective and effective for TcO 4 - removed from the SRS tank waste stream (~90% removed). The Ni-TIPA MOF sample containing ReO 4 - was prepared and shipped/planned for vitrification studies by a high-pressure technique. This research may provide a highly applicable platform for solving critical DOE and industrial problems related to nuclear environmental stewardship and nuclear power production.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Biomass Combustion in a Circulating Fluidized Bed Combustor

Interest in circulating fluidized bed (CFB) boilers as a power generation technology has skyrocketed in recent years because of several advantages this technology offers over conventional boilers, such as increased gas-solid mixing resulting in higher combustion efficiency and the ability to use lower quality fuels. CFB combustors are operated at lower temperatures than conventional thermal power generation combustors, thus reducing NO x emissions. SO 2 emissions are conveniently controlled through the addition of Ca-based sulphur sorbents within the combustor. This report summarizes the current modeling effort on a 50 kW th CFB combustor with a diameter of 10 cm and a height of 5 m; designed, built, and operated at CanmetENERGY in Ottawa, Canada employing the multiphase particle-in-cell (PIC) approach in the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite. The MFiX-PIC model parameters for the simulation are tuned against cold-flow experiments from CanmetENERGY using 9 kg of olivine sand as the inert bed material. It is shown that for the relatively coarse fluid meshes and large parcel sizes necessitated by the scale of the simulation, filter size dependent corrections to the drag law must be incorporated to ensure accuracy of the simulation results. The validated cold flow model is extended to simulate reacting flow with torrefied hardwood as the feedstock and to validate the combustion reaction scheme. The species concentrations at the riser outlet are compared against CanmetENERGY’s experiments and show satisfactory agreement. The simulations demonstrate the ability of MFiX-PIC to accurately capture the physics and chemistry of a circulating fluidized bed combustor at bench scales, which can be further extended to pilot- and industrial-scale systems.

20 FOSSIL-FUELED POWER PLANTS↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Mercury speciation using microcolumns with a direct mercury analyzer (DMA). Development of analytical method for the Savannah River Site liquid system

Mercury in the Savannah River Site (SRS) Liquid Waste System (LWS) exists in various forms, including: a) ionic inorganic mercury, organomercury (e.g., methyl Hg), and other less abundant species dissolved in LWS fluids, b) mercury solids such as oxides, hydroxides, amalgams, sulfides, and sorbed mercury, c) accumulations of dense liquid elemental mercury, and d) vapor phase elemental and organomercury mercury in tank headspace gas and in evaporators. Strategic and proactive management of the estimated 60,000 Kg mercury in the LWS requires deployment of efficient and effective paradigms for sampling and analysis of the total quantity of mercury in the various physical-chemical forms. Scoping tests of selective gas-phase sorbents for mercury speciation were performed to support LWS objectives. This research specifically focused on developing and testing streamlined methods to obtain high-quality analytical results for gaseous mercury species. The proposed methods are straightforward, using small columns (microcolumns) filled with materials that selectively sorb one or more target forms of mercury. Simple differentiation of mercury species and quantification is then achieved using an efficient thermal-desorption-based total mercury analyzer as the final step. Benefits associated with transitioning from multistep procedures such as EPA Methods 245.1, 1630 and 1631to streamlined microcolumn approaches include reduced analysis time, labor, and waste generation. Such transitioning would maximize the value of the current deployment of direct mercury analysis (EPA Method 7473) at SRS. This work has two target end uses: 1) simplifying the analysis steps and reducing costs for liquid samples (e.g., developing a total organic mercury (TOM) method), and 2) providing options for high-quality onsite analysis and rapid turnaround for gas samples in support of SRS LWS industrial hygiene (IH) objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fluorinated Covalent Organic Frameworks: A Novel Pathway to Enhance Hydrogen Sorption and Control Isosteric Heats of Adsorption; HyMARC Seed Project Final Report

Organic framework materials, as a unique sub-class of carbon-based sorbents, have gained increasing attention for promising attributes toward gas storage. Calculations of the hydrogen capacity of optimized frameworks show potential to achieve greater than 60 g/L storage of hydrogen, placing metal-organic frameworks (MOFs) and COFs near the top of the class of porous materials. However, at the ensemble level, poor stacking creates a quasi-amorphous material with low structural integrity and low effective surface area. The chemical versatility of COFs allows for additional methods for producing long-range order that specifically target the inter-layer interactions in COFs but that leave key pore-accessible linker sites open. These modifications (either during synthesis or post-synthetic) enable a host of strategies to both improve crystalline order for more stable and higher surface, as well as add metals with open coordination for enhanced H 2 binding enthalpy.

08 HYDROGEN↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct Air Capture of CO2 (DAC) [Tech Snapshot]

Researchers at Los Alamos have extensive capabilities in design, testing and optimization of: (1) new capture materials based on membrane separation, amine and other solvent and sorbent separation, and porous materials; (2) biological capture methods, particularly algae and plants; (3) full-scale systems using science-based virtual learning; and (4) system performance under specific meteorological conditions, impacts of CO2 capture via atmospheric data and simulations, and availability of energy and storage capacity. The goal for Los Alamos is advancing our physical technologies and engineered systems approaches from the development phase to a minimal viable product in the energy sector for commercial purposes. Los Alamos is seeking strategic commercialization partners to work with us in advancing these capabilities and technologies for commercial viability.

54 ENVIRONMENTAL SCIENCES↗

Full-Loop Simulation of the Combustion of Biomass in a Circulating Fluidized Bed Combustor

Interest in circulating fluidized bed (CFB) boilers as a power generation technology has skyrocketed in recent years because of several advantages this technology offers over conventional boilers, such as increased gas-solid mixing, which results in higher combustion efficiency, and the ability to use lower rank fuels. CFB combustors are operated at lower temperatures than conventional thermal power generation combustors, thus reducing NO x emissions, while SO 2 emissions can be conveniently controlled through the addition of Ca-based sulfur sorbents within the combustor. This report summarizes the development of a comprehensive computational fluid dynamics (CFD) model for biomass combustion in a 50 kW th CFB combustor employing the multiphase particle-in-cell (PIC) approach in the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite at the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL). The experimental combustor was designed, built, and operated at CanmetENERGY, Natural Resources Canada in Ottawa, Canada. This work is the culmination of a multi-year collaboration between NETL and CanmetENERGY. The hydrodynamics in the full loop are validated against cold-flow experiments conducted at CanmetENERGY. To mimic the dense packing in the standpipe in the absence of a collisional model in the MFiX-PIC approach, the ram valve in the return leg is partially closed to obstruct the flow. A combustion reaction scheme was developed that considers the volatiles released by the fuel as a lumped species that fully converts to CO 2 and H 2 O. The so-called enhanced simplified combustion scheme produces an excellent match with experimental data in terms of the species concentrations of CO 2 and O 2 at the outlet and the freeboard, demonstrating the utility of the comprehensive model for a range of flow conditions and operating temperatures. Furthermore, the model can be readily adapted to simulate combustion of a variety of biomass fuels as well as co-fired systems under air and oxy-fuel conditions.

09 BIOMASS FUELS↗

Final Report on Aerosol Pretreatment Technology Performance and Benchmarking

Solvent-based post-combustion CO 2 capture (PCC) technology remains one of the leading methods to combat global CO 2 emissions produced from large-scale coal-fired power production. Advanced solventbased PCC technology has made significant improvements in design and performance that reduce capital and operating costs to enable its commercial use. Key to low cost, manageable logistics, and environmentally safe operation of solvent-based PCC technology are minimal solvent losses from the process through the treated gas stream exiting PCC plant absorbers. High flue gas aerosol particle concentrations (>10 5 particles/cm 3 ) for particles in the range of 70-200 nm have been shown to cause significant amine solvent losses for solvent-based PCC processes through several mechanisms including absorption of solvent and water into growing aerosol particles. Flue gas aerosol pretreatment technology is the only realistic and economically attractive method to reduce very high aerosol particle concentrations (>10 7 particles/cm 3 ) to enable solvent-based PCC for existing power plants lacking sufficient particle removal systems, such as baghouses. The overall goal of this project was to design, construct, independently test, and evaluate three flue gas aerosol pretreatment technologies identified to significantly reduce high aerosol particle concentrations (>10 7 particles/cm 3 ) in the 70-200 nm particle size range: (1) a novel, high-velocity water injection spray concept developed by RWE and tested by Linde, (2) an innovative electrostatic precipitator (ESP) device with optimized operating conditions developed by Washington University in St. Louis (WUSTL), and (3) a non-regenerative sorbent-based filter technology developed by InnoSepra for SO x and NO x removal from coal-fired power plant flue gas. Each technology has been validated with tests on 500-1000 scfm of actual coal-fired flue gas and evaluated in terms of particle removal efficiency (%), cost competitiveness, and environmental impact. Aerosol measurements were performed upstream and downstream of each aerosol reduction unit during independent testing of each technology using advanced instrumentation and analytical methods provided by WUSTL. To perform aerosol measurements, isokinetic probes were inserted into flanged pipes attached to the flue gas piping, and a small suction pump was used to sample gas containing aerosol particles. Aerosol particle number concentrations (# particles/cm 3 ) and size distributions were then measured using a scanning mobility particle sizer (SMPS, TSI Inc.) for very fine particles (<1,000 nm) and a particle counter manufactured by GRIMM for particles larger than 1,000 nm. This report summarizes the aerosol removal performance results from pilot scale testing of each technology. Performance results have been benchmarked against pre-defined targets and other flue gas aerosol pretreatment technologies with documented performance. Linde Gas North America LLC has been the prime contractor to DOE responsible for overall project management and provided the design for the high-velocity water spray-based aerosol removal technology based on a design concept developed by the German utility company RWE.

20 FOSSIL-FUELED POWER PLANTS↗

Metal Organic Frameworks for Noble Gas Management in the Liquid Fluoride Thorium Reactor (LFTR) (CRADA 459)

The purpose of this project is to demonstrate the novel class of materials known as metal organic frameworks (MOFs) to capture Xe selectively from simulated LFTR off gas. This will establish the viability of designing a dramatically improved approach to noble gas management as compared to activated carbon. However, there are significant data gaps that need to be addressed in order to deploy this technology for LFTRs that include i) converting MOF powders into engineered forms to produce mechanically robust particles, ii) the radiation stability and associated mechanism of degradation (if any) upon irradiation of these sorbent materials and iii) demonstration and comparison to activated carbon of the noble gas separation from simulated LFTR gas stream.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Combined Water and CO2 Direct Air Capture System (CRADA 521)

The primary objective of this project is to demonstrate the outstanding technical and economic performance of a transformational Hybrid DAC (HDAC) technology that simultaneously captures CO2 and water from the air. Air is passed over a CO2 selective sorbent to remove ≥85% of the CO2 from the air stream. The atmospheric water extraction (AWE) section of the unit utilizes a novel isothermal pressure swing regeneration cycle with desiccant beds thermally coupled by heat pipes that provide a passive heat transfer mechanism to “cancel” the heat of water vapor adsorption. By proving system performance through this demonstration project, our initial technoeconomic analysis (TEA) will be validated, showing that HDAC technology: 1) is deployable in many more locations with limited water resources, 2) improves the financial returns, and 3) reduces risks from volatility in the price of CO2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

University of Minnesota, Twin Cities Final Scientific/Technical Report Small Scale Ammonia Synthesis Using Stranded Wind Energy

Ammonia absorber columns offer an alternative separation unit to replace condensation in the Haber-Bosch synthesis loop. Metal halide salts can selectively separate ammonia from the reactor outlet gas mixture and incorporate it into their crystal lattice with remarkably high thermodynamic capacity. While the salts’ working capacity can be limited and unstable when they are in their pure form, the capacity is stable and can be high when using a porous ceramic support. In this project, we found optimal conditions for sorbent fabrication, we demonstrated benchmark levels of uptake and release of ammonia, and we fabricated and demonstrated a prototype at a scale of 1 kg/day ammonia. This task allowed us to assess improvement in the techno-economic prospects for this new separation approach, making viable more distributed production of green ammonia from geographically dispersed renewable energy sources.

08 HYDROGEN↗

Formation Mechanisms, Crystal Structure, and Interfacial Reactivity of (Mixed) Metal Sulfide Nanoparticles Produced via Biological versus Abiotic Systems

The primary goals of this project were to understand the formation mechanisms and reactivity of mix-metal sulfide nanophases (Cu-Fe, Ni-Fe, Co-Fe sulfides) produced via biological and abiotic pathways that are relevant to low-temperature aqueous environments. These mix-metal sulfide nanophases have been identified in a range of natural and anthropogenic systems and are considered to play key roles in the biogeochemical cycling of elements, biomineralization, environmental remediation, resource recovery, eco-toxicity, and the origin and evolution of life. Using a comparative approach, we aimed to elucidate: (i) if these mix-metal sulfides tend to form nanoscale phases regardless of their formation pathways; (ii) what mechanisms are involved in the biological and abiotic crystallization processes; (iii) what phases form that have been otherwise expected; and (iv) if we can combine the experimental results with what we see and surmise from field studies to facilitate a more comprehensive understanding regarding the origin and biogeochemical roles of these mix-metal sulfides. Along a related pathway of electron transfer in nano-systems, in this case dealing with Fe-oxides instead of Fe-sulfides, we have continued to explore the reactions and solid products of heterogeneous catalytic oxidation of aqueous Mn(II) by dissolved oxygen in the presence of iron oxides (hematite) nanoparticles. The nano-Mn-oxides produced are known to be efficient sorbents of transition metal elements, including Cu, Ni, and Co studied in our sulfide work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Abstract for Umbrella CRADA between NETL and Susteon, Inc. (AGMT-0983)

NETL and Susteon will develop new technologies involving catalysts, sorbents, and membrane materials. These materials will be incorporated into chemical processes, scaled up, and evaluated for commercialization potential. Areas of interest include technologies for shale and natural gas processing and utilization; hydrogen production and processing; coal and syngas processing; and CO 2 capture and utilization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗