Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source code (Computer science)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

SU-E-J-249: Correlation of Mean Lung Ventilation Value with Ratio of Total Lung Volumes

Purpose: Lung ventilation function measured from 4D-CT and from breathing correlated CT images is a novel concept to incorporate the lung physiologic function into treatment planning of radiotherapy. The calculated ventilation functions may vary from different breathing patterns, affecting evaluation of the treatment plans. The purpose of this study is to correlate the mean lung ventilation value with the ratio of the total lung volumes obtained from the relevant CTs. Methods: A ventilation map was calculated from the variations of voxel-to-voxel CT densities from two breathing phases from either 4D-CT or breathing correlated CTs. An open source image registration tool of Plastimatch was used to deform the inhale phase images to the exhale phase images. To calculate the ventilation map inside lung, the whole lung was delineated and the tissue outside the lung was masked out. With a software tool developed in house, the 3D ventilation map was then converted in the DICOM format associated with the planning CT images. The ventilation map was analyzed on a clinical workstation. To correlate ventilation map thus calculated with lung volume change, the total lung volume change was compared the mean ventilation from our method. Results: Twenty two patients who underwent stereotactic body irradiation for lung cancer was selected for this retrospective study. For this group of patients, the ratio of lung volumes for the inhale (Vin ) and exhale phase (Vex ) was shown to be linearly related to the mean of the local ventilation (Vent), Vin/Vex=1.+0.49*Vent (R2=0.93, p<0.01). Conclusion: The total lung volume change is highly correlated with the mean of local ventilation. The mean of local ventilation may be useful to assess the patient's lung capacity.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-06: Feasibility of External Beam Treatment Field Verification Using Cherenkov Imaging

Purpose: Cherenkov light emission has been shown to correlate with ionizing radiation (IR) dose delivery in solid tissue. In order to properly correlate Cherenkov light images with real time dose delivery in a patient, we must account for geometric and intensity distortions arising from observation angle, as well as the effect of monitor units (MU) and field size on Cherenkov light emission. To test the feasibility of treatment field verification, we first focused on Cherenkov light emission efficiency based on MU and known field size (FS). Methods: Cherenkov light emission was captured using a PI-MAX4 intensified charge coupled device(ICCD) system (Princeton Instruments), positioned at a fixed angle of 40° relative to the beam central axis. A Varian TrueBeam linear accelerator (linac) was operated at 6MV and 600MU/min to deliver an Anterior-Posterior beam to a 5cm thick block phantom positioned at 100cm Source-to-Surface-Distance(SSD). FS of 10×10, 5×5, and 2×2cm{sup 2} were used. Before beam delivery projected light field images were acquired, ensuring that geometric distortions were consistent when measuring Cherenkov field discrepancies. Cherenkov image acquisition was triggered by linac target current. 500 frames were acquired for each FS. Composite images were created through summation of frames and background subtraction. MU per image was calculated based on linac pulse delay of 2.8ms. Cherenkov and projected light FS were evaluated using ImageJ software. Results: Mean Cherenkov FS discrepancies compared to light field were <0.5cm for 5.6, 2.8, and 8.6 MU for 10×10, 5×5, and 2×2cm{sup 2} FS, respectably. Discrepancies were reduced with increasing field size and MU. We predict a minimum of 100 frames is needed for reliable confirmation of delivered FS. Conclusion: Current discrepancies in Cherenkov field sizes are within a usable range to confirm treatment delivery in standard and respiratory gated clinical scenarios at MU levels appropriate to standard MLC position segments.

60 APPLIED LIFE SCIENCES↗

Simulation of Intense Beams and Targets for Heavy-Ion-Fusion Science (HEDLP / Inertial Fusion Energy)

Our principal goals, and activities in support of those goals, over the next five years are as follows: (1) Optimize the properties of the NDCX-II beam for each class of target experiments; achieve quantitative agreement with measurements; develop improved machine configurations and operating points. To accomplish these goals, we plan to use Warp to simulate NDCX-II from source to target, in full kinetic detail, including first-principles modeling of beam neutralization by plasma. The output from an ensemble of Warp runs (representing shot-to-shot variations) will be used as input to target simulations using ALE-AMR on NERSC, and other codes. (2) Develop enhanced versions of NDCX-II (the machine is designed to be extensible and reconfigurable), and carry out studies to define a next-step ion beam facility. To accomplish these goals, much of the work will involve iterative optimization employing Warp runs that assume ideal beam neutralization downstream of the accelerator. (3) Carry out detailed target simulations in the Warm Dense Matter regime using the ALE-AMR code, including surface tension effects, liquid-vapor coexistence, and accurate models of both the driving beam and the target geometry. For this we will need to make multiple runs (to capture shot-to-shot variations), and to both develop and employ synthetic diagnostics (to enable comparison with experiments). The new science that will be revealed is the physics of the transition from the liquid to vapor state of a volumetrically superheated material, wherein droplets are formed, and wherein phase transitions, surface tension and hydrodynamics all play significant roles in the dynamics. These simulations will enable calculations of equation of state and other material properties, and will also be of interest for their illumination of the science of droplet formation.

43 PARTICLE ACCELERATORS↗

SU-F-T-53: Treatment Planning with Inhomogeneity Correction for Intraoperative Radiotherapy Using KV X-Ray Beams

Purpose: The current standard in dose calculation for intraoperative radiotherapy (IORT) using the ZEISS Intrabeam 50 kV x-ray system is based on depth dose measurements in water and no heterogeneous tissue effect has been taken into account. We propose an algorithm for pre-treatment planning including inhomogeneity correction based on data of depth dose measurements in various tissue phantoms for kV x-rays. Methods: Direct depth dose measurements were made in air, water, inner bone and cortical bone phantoms for the Intrabeam 50 kV x-rays with a needle applicator. The data were modelled by a function of power law combining exponential with different parameters. Those phantom slabs used in the measurements were scanned to obtain CT numbers. The x-ray beam initiated from the source isocenter is ray-traced through tissues. The corresponding doses will be deposited/assigned at different depths. On the boundary of tissue/organ changes, the x-ray beam will be re-traced in new tissue/organ starting at an equivalent depth with the same dose. In principle, a volumetric dose distribution can be generated if enough directional beams are traced. In practice, a several typical rays traced may be adequate in providing estimates of maximum dose to the organ at risk and minimum dose in the target volume. Results: Depth dose measurements and modeling are shown in Figure 1. The dose versus CT number is shown in Figure 2. A computer program has been written for Kypho-IORT planning using those data. A direct measurement through 2 mm solid water, 2 mm inner bone, and 1 mm solid water yields a dose rate of 7.7 Gy/min. Our calculation shows 8.1±0.4 Gy/min, consistent with the measurement within 5%. Conclusion: The proposed method can be used to more accurately calculate the dose by taking into account the heterogeneous effect. The further validation includes comparison with Monte Carlo simulation.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-01: Automated Dose Deformation for Re-Irradiation

Purpose: An objective of retreatment planning is to minimize dose to previously irradiated tissues. Conventional retreatment planning is based largely on best-guess superposition of the previous treatment’s isodose lines. In this study, we report a rigorous, automated retreatment planning process to minimize dose to previously irradiated organs at risk (OAR). Methods: Data for representative patients previously treated using helical tomotherapy and later retreated in the vicinity of the original disease site were retrospectively analyzed in an automated fashion using a prototype treatment planning system equipped with a retreatment planning module (Accuray, Inc.). The initial plan’s CT, structures, and planned dose were input along with the retreatment CT and structure set. Using a deformable registration algorithm implemented in the module, the initially planned dose and structures were warped onto the retreatment CT. An integrated third-party sourced software (MIM, Inc.) was used to evaluate registration quality and to contour overlapping regions between isodose lines and OARs, providing additional constraints during retreatment planning. The resulting plan and the conventionally generated retreatment plan were compared. Results: Jacobian maps showed good quality registration between the initial plan and retreatment CTs. For a right orbit case, the dose deformation facilitated delineating the regions of the eyes and optic chiasm originally receiving 13 to 42 Gy. Using these regions as dose constraints, the new retreatment plan resulted in V50 reduction of 28% for the right eye and 8% for the optic chiasm, relative to the conventional plan. Meanwhile, differences in the PTV dose coverage were clinically insignificant. Conclusion: Automated retreatment planning with dose deformation and definition of previously-irradiated regions allowed for additional planning constraints to be defined to minimize re-irradiation of OARs. For serial organs that do not recover from radiation damage, this method provides a more precise and quantitative means to limit cumulative dose. This research is partially supported by Accuray, Inc.

60 APPLIED LIFE SCIENCES↗

InSAR Scientific Computing Environment

This computing environment is the next generation of geodetic image processing technology for repeat-pass Interferometric Synthetic Aperture (InSAR) sensors, identified by the community as a needed capability to provide flexibility and extensibility in reducing measurements from radar satellites and aircraft to new geophysical products. This software allows users of interferometric radar data the flexibility to process from Level 0 to Level 4 products using a variety of algorithms and for a range of available sensors. There are many radar satellites in orbit today delivering to the science community data of unprecedented quantity and quality, making possible large-scale studies in climate research, natural hazards, and the Earth's ecosystem. The proposed DESDynI mission, now under consideration by NASA for launch later in this decade, would provide time series and multiimage measurements that permit 4D models of Earth surface processes so that, for example, climate-induced changes over time would become apparent and quantifiable. This advanced data processing technology, applied to a global data set such as from the proposed DESDynI mission, enables a new class of analyses at time and spatial scales unavailable using current approaches. This software implements an accurate, extensible, and modular processing system designed to realize the full potential of InSAR data from future missions such as the proposed DESDynI, existing radar satellite data, as well as data from the NASA UAVSAR (Uninhabited Aerial Vehicle Synthetic Aperture Radar), and other airborne platforms. The processing approach has been re-thought in order to enable multi-scene analysis by adding new algorithms and data interfaces, to permit user-reconfigurable operation and extensibility, and to capitalize on codes already developed by NASA and the science community. The framework incorporates modern programming methods based on recent research, including object-oriented scripts controlling legacy and new codes, abstraction and generalization of the data model for efficient manipulation of objects among modules, and well-designed module interfaces suitable for command- line execution or GUI-programming. The framework is designed to allow users contributions to promote maximum utility and sophistication of the code, creating an open-source community that could extend the framework into the indefinite future.

Rosen, Paul A.↗

LUXSim: A component-centric approach to low-background simulations

Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpoint, there is no single source or beam, but rather a collection of sources with potentially complicated spatial extent. LUXSim is a simulation framework used by the LUX collaboration that takes a component-centric approach to event generation and recording. A new set of classes allows for multiple radioactive sources to be set within any number of components at run time, with the entire collection of sources handled within a single simulation run. Various levels of information can also be recorded from the individual components, with these record levels also being set at runtime. This flexibility in both source generation and information recording is possible without the need to recompile, reducing the complexity of code management and the proliferation of versions. Within the code itself, casting geometry objects within this new set of classes rather than as the default Geant4 classes automatically extends this flexibility to every individual component. No additional work is required on the part of the developer, reducing development time and increasing confidence in the results. Here, we describe the guiding principles behind LUXSim, detail some of its unique classes and methods, and give examples of usage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-137: Dosimetric Validation for Pinnacle, Acuros, AAA, and Brainlab Algorithms with Induced Inhomogenieties

Purpose: To compare the dosimetric accuracy of the Eclipse 11.0 Acuros XB and Anisotropic Analytical Algorithm (AAA), Pinnacle-3 9.2 Collapsed Cone Convolution, and the iPlan 4.1 Monte Carlo (MC) and Pencil Beam (PB) algorithms using measurement as the gold standard. Methods: Ion chamber and diode measurements were taken for 6, 10, and 18 MV beams in a phantom made up of slab densities corresponding to solid water, lung, and bone. The phantom was setup at source-to-surface distance of 100 cm, and the field sizes were 3.0 × 3.0, 5.0 × 5.0, and 10.0 × 10.0 cm2. Data from the planning systems were computed along the central axis of the beam. The measurements were taken using a pinpoint chamber and edge diode for interface regions. Results: The best agreement between data from the algorithms and our measurements occurs away from the slab interfaces. For the 6 MV beam, iPlan 4.1 MC software performs the best with 1.7% absolute average percent difference from measurement. For the 10 MV beam, iPlan 4.1 PB performs the best with 2.7% absolute average percent difference from measurement. For the 18 MV beam, Acuros performs the best with 2.0% absolute average percent difference from measurement. It is interesting to note that the steepest drop in dose occurred the at lung heterogeneity-solid water interface of the18 MV, 3.0 × 3.0 cm2 field size setup. In this situation, Acuros and AAA performed best with an average percent difference within −1.1% of measurement, followed by iPlan 4.1 MC, which was within 4.9%. Conclusion: This study shows that all of the algorithms perform reasonably well in computing dose in a heterogeneous slab phantom. Moreover, Acuros and AAA perform particularly well at the lung-solid water interfaces for higher energy beams and small field sizes.

60 APPLIED LIFE SCIENCES↗

miss-SNF: a multimodal patient similarity network integration approach to handle completely missing data sources

Abstract Motivation Precision medicine leverages patient-specific multimodal data to improve prevention, diagnosis, prognosis, and treatment of diseases. Advancing precision medicine requires the non-trivial integration of complex, heterogeneous, and potentially high-dimensional data sources, such as multi-omics and clinical data. In the literature, several approaches have been proposed to manage missing data, but are usually limited to the recovery of subsets of features for a subset of patients. A largely overlooked problem is the integration of multiple sources of data when one or more of them are completely missing for a subset of patients, a relatively common condition in clinical practice. Results We propose miss-Similarity Network Fusion (miss-SNF), a novel general-purpose data integration approach designed to manage completely missing data in the context of patient similarity networks. miss-SNF integrates incomplete unimodal patient similarity networks by leveraging a non-linear message-passing strategy borrowed from the SNF algorithm. miss-SNF is able to recover missing patient similarities and is “task agnostic”, in the sense that can integrate partial data for both unsupervised and supervised prediction tasks. Experimental analyses on nine cancer datasets from The Cancer Genome Atlas (TCGA) demonstrate that miss-SNF achieves state-of-the-art results in recovering similarities and in identifying patients subgroups enriched in clinically relevant variables and having differential survival. Moreover, amputation experiments show that miss-SNF supervised prediction of cancer clinical outcomes and Alzheimer’s disease diagnosis with completely missing data achieves results comparable to those obtained when all the data are available. Availability and implementation miss-SNF code, implemented in R, is available at https://github.com/AnacletoLAB/missSNF.

Biochemistry & Molecular Biology↗

SU-E-J-144: Low Activity Studies of Carbon 11 Activation Via GATE Monte Carlo

Purpose: To investigate the behavior of a Monte Carlo simulation code with low levels of activity (∼1,000Bq). Such activity levels are expected from phantoms and patients activated via a proton therapy beam. Methods: Three different ranges for a therapeutic proton radiation beam were examined in a Monte Carlo simulation code: 13.5, 17.0 and 21.0cm. For each range, the decay of an equivalent length{sup 11}C source and additional sources of length plus or minus one cm was studied in a benchmark PET simulation for activities of 1000, 2000 and 3000Bq. The ranges were chosen to coincide with a previous activation study, and the activities were chosen to coincide with the approximate level of isotope creation expected in a phantom or patient irradiated by a therapeutic proton beam. The GATE 7.0 simulation was completed on a cluster node, running Scientific Linux Carbon 6 (Red Hat©). The resulting Monte Carlo data were investigated with the ROOT (CERN) analysis tool. The half-life of{sup 11}C was extracted via a histogram fit to the number of simulated PET events vs. time. Results: The average slope of the deviation of the extracted carbon half life from the expected/nominal value vs. activity showed a generally positive value. This was unexpected, as the deviation should, in principal, decrease with increased activity and lower statistical uncertainty. Conclusion: For activity levels on the order of 1,000Bq, the behavior of a benchmark PET test was somewhat unexpected. It is important to be aware of the limitations of low activity PET images, and low activity Monte Carlo simulations. This work was funded in part by the Philips corporation.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-02: Accuracy Evaluation of GPU-Based OpenCL Carbon Monte Carlo Package (goCMC) in Biological Dose and Microdosimetry in Comparison to FLUKA Simulations

Purpose: One of the most accurate methods for radiation transport is Monte Carlo (MC) simulation. Long computation time prevents its wide applications in clinic. We have recently developed a fast MC code for carbon ion therapy called GPU-based OpenCL Carbon Monte Carlo (goCMC) and its accuracy in physical dose has been established. Since radiobiology is an indispensible aspect of carbon ion therapy, this study evaluates accuracy of goCMC in biological dose and microdosimetry by benchmarking it with FLUKA. Methods: We performed simulations of a carbon pencil beam with 150, 300 and 450 MeV/u in a homogeneous water phantom using goCMC and FLUKA. Dose and energy spectra for primary and secondary ions on the central beam axis were recorded. Repair-misrepair-fixation model was employed to calculate Relative Biological Effectiveness (RBE). Monte Carlo Damage Simulation (MCDS) tool was used to calculate microdosimetry parameters. Results: Physical dose differences on the central axis were <1.6% of the maximum value. Before the Bragg peak, differences in RBE and RBE-weighted dose were <2% and <1%. At the Bragg peak, the differences were 12.5% caused by small range discrepancy and sensitivity of RBE to beam spectra. Consequently, RBE-weighted dose difference was 11%. Beyond the peak, RBE differences were <20% and primarily caused by differences in the Helium-4 spectrum. However, the RBE-weighted dose agreed within 1% due to the low physical dose. Differences in microdosimetric quantities were small except at the Bragg peak. The simulation time per source particle with FLUKA was 0.08 sec, while goCMC was approximately 1000 times faster. Conclusion: Physical doses computed by FLUKA and goCMC were in good agreement. Although relatively large RBE differences were observed at and beyond the Bragg peak, the RBE-weighted dose differences were considered to be acceptable.

60 APPLIED LIFE SCIENCES↗

Improving the performance of medical imaging applications using SYCL

As opposed to the Open Computing Language (OpenCL) programming model, in which host and device codes are generally written in different programming languages, SYCL can combine host and device codes for an application in a type-safe way to improve development productivity and performance portability. Hence, this report shows the experimental results of applying the SYCL programming model to medical imaging applications for a study on performance portability and programming productivity between OpenCL and SYCL. Rodinia is a widely used open-source benchmark suite for heterogeneous computing. We choose two medical imaging applications (Heart Wall and Particle Filter) in the benchmark suite, migrate the OpenCL implementations of the applications to the SYCL implementations, and evaluate their performance and productivity on Intel® microprocessors that contain a central processing unit (CPU) and an integrated graphics processing unit (GPU). The maturing SYCL compilers, which are based on a conformant implementation of the SYCL 1.2.1 Khronos specification, have been actively optimized for Intel® computing platforms. The experimental results are promising in terms of the raw performance and productivity. Although the SYCL implementation of the Heart Wall application does not execute successfully on a CPU, the SYCL implementations of the application can achieve comparable or better performance than the OpenCL implementation on Intel® integrated GPUs. For the Particle Filter application, the performance difference between the SYCL and OpenCL implementations is comparable on the GPUs for most cases, but the SYCL implementations are on average 4X faster than the OpenCL implementations on Intel® Xeon® CPUs. For programming productivity, we arguably use lines of code as a way to measure programming productivity in software. The SYCL programs reduce the lines of code of the OpenCL programs by 52% and 38% for the Heart Wall and Particle Filter, respectively. The results indicate that SYCL is a promising programming model for heterogeneous computing with the maturing compilers. We organize the remainder of the report as follows. Section II introduces the SYCL programming model, compares the major differences between an OpenCL program and a SYCL program, and describes the characteristics of the two applications. Section III describes the SYCL programming model in more details, and shows the SYCL implementation of a kernel function in the Particle Filter application as an example. In Section IV, we evaluate the performance of the applications on the CPUs and GPUs. Section V concludes the report.

59 BASIC BIOLOGICAL SCIENCES↗

Benchmark of the KGMf with a coupled Boltzmann equation solver

The Kinetic Global Model framework (KGMf) is an open-source general-purpose global model (spatially averaged) simulation code developed to explore the reaction kinetics and pathways in plasma discharge systems. It contains species continuity and electron energy balance equations, with a time-dependent evaluated electron energy distribution function (EEDF) for electron impact reactions. The EEDF is utilized to determine the rate coefficients for electron impact reactions, which can have profound impact on the temporal evolutions of plasma parameters. Previously, the EEDF was commonly assumed as Maxwellian or an analytical function of the effective electron temperature. In this work, the KGMf is coupled with a Boltzmann equation (BE) solver to self-consistently compute the EEDF. The EEDF evolution frequency is determined based on relative changes of the reduced electric field. The KGMf is benchmarked with the ZDPlasKin code based on high-pressure low-temperature argon plasma discharge cases. Additionally, the temporal evolutions of reduced electric field, electron temperature, EEDF, reaction rates, and species densities, are obtained and compared under different discharge conditions, showing good agreement between the KGMf and the ZDPlasKin simulations. The application of the KGMf for predicting breakdown times in high power microwave discharges is also presented, which shows qualitative agreement with particle-in-cell simulations. The KGMf can be further applied for more complicated plasma discharge systems, where the reaction kinetics are more intricate (e.g., plasma-assisted combustion systems).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mesoscale Numerical Characterization of Kevlar and Carbon–Kevlar Hybrid Plain-Woven Fabric Compression Behavior

A mesoscale finite element model (FEM) of the plain-woven fabric representative elementary volume (REV/unit cell) is developed. The developed FEM is used to predict the nonlinear compaction behavior of monolithic and intraply hybrid fabric made of high-strength carbon and Kevlar fibers. For geometrical modeling of the fabric REV, TexGen, an open-source geometrical modeling software (developed at Nottingham University), is utilized, and for mechanical characterization, FE simulation tool Abaqus{sup ®} is used. Geometrical nonlinearity of the fabric, including periodic boundary conditions and yarn interactions, is incorporated in the REV FE model. Material nonlinearity caused by transversely isotropic behavior of fibrous yarns is implemented through the user material subroutine form in FE simulation along with local orientation assigned to each yarn in the REV. Material properties of fibers are extracted from the literature and supplier data. The compression behavior of monolithic Kevlar and hybrid carbon–Kevlar (carbon warp and Kevlar weft yarns, C–K) fabric is predicted using the proposed FE model. FEM-predicted results were found to have good agreement with the experimentally obtained ones. Results depict that C–K hybrid fabrics have improved compression strength. Hybridization effect is governed by yarns mutual interaction, yarn area at crossovers, and transverse in-plane properties of the interyarn hybridized fabric. The proposed FE model can be used to predict the mechanical behavior of woven fabrics with different weaving patterns, unit cell geometry, material properties, and loading conditions.

36 MATERIALS SCIENCE↗

Numerical coupling of aerosol emissions, dry removal, and turbulent mixing in the E3SM Atmosphere Model version 1 (EAMv1) – Part 1: Dust budget analyses and the impacts of a revised coupling scheme

Abstract. An earlier study evaluating dust life cycle in the Energy Exascale Earth System Model (E3SM) Atmosphere Model version 1 (EAMv1) has revealed that the simulated global mean dust lifetime is substantially shorter when higher vertical resolution is used, primarily due to significant strengthening of dust dry removal in source regions. This paper demonstrates that the sequential splitting of aerosol emissions, dry removal, and turbulent mixing in the model's time integration loop, especially the calculation of dry removal after surface emissions and before turbulent mixing, is the primary reason for the vertical resolution sensitivity reported in that earlier study. Based on this reasoning, we propose a revised numerical process coupling scheme that requires the least amount of code changes, in which the surface emissions are applied before turbulent mixing instead of before dry removal. The revised scheme allows newly emitted particles to be transported aloft by turbulence before being removed from the atmosphere, and hence better resembles the dust life cycle in the real world. Sensitivity experiments show that the revised process coupling substantially weakens dry removal and strengthens vertical mixing in dust source regions. It also strengthens the large-scale transport from source to non-source regions, strengthens dry removal outside the source regions, and strengthens wet removal and activation globally. In transient simulations of the years 2000–2009 conducted using 1∘ horizontal grid spacing, 72 vertical layers, and unchanged tuning parameters of emission strength, the revised process coupling leads to a 40 % increase in the global total dust burden and an increase of dust lifetime from 1.8 to 2.5 d in terms of 10-year averages. Weakened dry removal and increased mixing ratios are also seen for other aerosol species that have substantial surface emissions, although the changes in mixing ratio are considerably smaller for the submicron species than for dust and sea salt. Numerical experiments confirm that the revised coupling scheme significantly reduces the strong and non-physical sensitivities of model results to vertical resolution in the original EAMv1. This provides a motivation for adopting the revised scheme in EAM as well as for further improvements on the simple revision presented in this paper.

54 ENVIRONMENTAL SCIENCES↗

Machine Learning assisted optimization and parameter space exploration dataset of spin ice Hamiltonian

This repository contains both simulated and experimental structure factor data for the data challenge involving the inverse scattering problem. The simulated data were generated during a machine-learning-assisted optimization routine described in ref[1]. The experimental structure factor was measured on a rare-earth oxide, Dy2Ti2O7 using diffuse neutron scattering from time-of-flight techniques on the CORELLI instrument at the Spallation Neutron Source, Oak Ridge National Laboratory. A Metropolis Monte Carlo code implemented to run in a High-performance computing setting was used to calculated simulated structure factors for the spin-ice Hamiltonian at 680 mK, which is the same temperature as for the experimental data. The total size of all the files in this repository is 5.12 GB. A detailed description of the files is given below. ExperimentalData_630mK.dat – A linearized version of 3-dimensional experimental data of size 61×81×21. This data was processed to remove an estimation of non-magnetic background, including nuclear scattering signal and instrumentation background. Parameters.dat – 6700 samples were evaluated over the 4-dimensional parameter space (J_1, J_2, J_3 and J_(3^' )). There is an additional parameter, D in the spin Hamiltonian to mimic the dipolar interaction between magnetic ions. However, this parameter, D was fixed to a value determined by prior work. This file contains five columns for the parameters J_1, J_2, J_3, J_(3^' ) and D respectively. 3D_Simulation_Data.dat – The simulated structure factor, S(Q) data are included in this file. Each raw contains a linearized array of 3D volumes of S(Q) calculated for the parameter set given in the corresponding row of the file Parameters.dat. The size of the volume data was matched to the experimental data. Qx(h,-h,0).dat, Qy(k,k,-2k).dat, Qz(l,l,l).dat – These files contain the h, k, and l values along with the reciprocal vectors [h,-h,0], [k,k,-2k] and [l,l,l] respectively.

36 MATERIALS SCIENCE↗

SU-E-J-10: A Moving-Blocker-Based Strategy for Simultaneous Megavoltage and Kilovoltage Scatter Correction in Cone-Beam Computed Tomography Image Acquired During Volumetric Modulated Arc Therapy

Purpose: To evaluate a moving-blocker-based approach in estimating and correcting megavoltage (MV) and kilovoltage (kV) scatter contamination in kV cone-beam computed tomography (CBCT) acquired during volumetric modulated arc therapy (VMAT). Methods: XML code was generated to enable concurrent CBCT acquisition and VMAT delivery in Varian TrueBeam developer mode. A physical attenuator (i.e., “blocker”) consisting of equal spaced lead strips (3.2mm strip width and 3.2mm gap in between) was mounted between the x-ray source and patient at a source to blocker distance of 232mm. The blocker was simulated to be moving back and forth along the gantry rotation axis during the CBCT acquisition. Both MV and kV scatter signal were estimated simultaneously from the blocked regions of the imaging panel, and interpolated into the un-blocked regions. Scatter corrected CBCT was then reconstructed from un-blocked projections after scatter subtraction using an iterative image reconstruction algorithm based on constraint optimization. Experimental studies were performed on a Catphan 600 phantom and an anthropomorphic pelvis phantom to demonstrate the feasibility of using moving blocker for MV-kV scatter correction. Results: MV scatter greatly degrades the CBCT image quality by increasing the CT number inaccuracy and decreasing the image contrast, in addition to the shading artifacts caused by kV scatter. The artifacts were substantially reduced in the moving blocker corrected CBCT images in both Catphan and pelvis phantoms. Quantitatively, CT number error in selected regions of interest reduced from 377 in the kV-MV contaminated CBCT image to 38 for the Catphan phantom. Conclusions: The moving-blockerbased strategy can successfully correct MV and kV scatter simultaneously in CBCT projection data acquired with concurrent VMAT delivery. This work was supported in part by a grant from the Cancer Prevention and Research Institute of Texas (RP130109) and a grant from the American Cancer Society (RSG-13-326-01-CCE)

60 APPLIED LIFE SCIENCES↗

Critical Issues on Materials for Gen-IV Reactors

Within the LDRD on 'Critical Issues on Materials for Gen-IV Reactors' basic thermodynamics of the Fe-Cr alloy and accurate atomistic modeling were used to help develop the capability to predict hardening, swelling and embrittlement using the paradigm of Multiscale Materials Modeling. Approaches at atomistic and mesoscale levels were linked to build-up the first steps in an integrated modeling platform that seeks to relate in a near-term effort dislocation dynamics to polycrystal plasticity. The requirements originated in the reactor systems under consideration today for future sources of nuclear energy. These requirements are beyond the present day performance of nuclear materials and calls for the development of new, high temperature, radiation resistant materials. Fe-Cr alloys with 9-12% Cr content are the base matrix of advanced ferritic/martensitic (FM) steels envisaged as fuel cladding and structural components of Gen-IV reactors. Predictive tools are needed to calculate structural and mechanical properties of these steels. This project represents a contribution in that direction. The synergy between the continuous progress of parallel computing and the spectacular advances in the theoretical framework that describes materials have lead to a significant advance in our comprehension of materials properties and their mechanical behavior. We took this progress to our advantage and within this LDRD were able to provide a detailed physical understanding of iron-chromium alloys microstructural behavior. By combining ab-initio simulations, many-body interatomic potential development, and mesoscale dislocation dynamics we were able to describe their microstructure evolution. For the first time in the case of Fe-Cr alloys, atomistic and mesoscale were merged and the first steps taken towards incorporating ordering and precipitation effects into dislocation dynamics (DD) simulations. Molecular dynamics (MD) studies of the transport of self-interstitial, vacancy and point defect clusters in concentrated Fe-Cr alloys were performed for future diffusion data calculations. A recently developed parallel MC code with displacement allowed us to predict the evolution of the defect microstructures, local chemistry changes, grain boundary segregation and precipitation resulting from radiation enhanced diffusion. We showed that grain boundaries, dislocations and free surfaces are not preferential for alpha-prime precipitation, and explained experimental observations of short-range order (SRO) in Fe-rich FeCr alloys. Our atomistic studies of dislocation hardening allowed us to obtain dislocation mobility functions for BCC pure iron and Fe-Cr and determine for FCC metals the dislocation interaction with precipitates with a description to be used in Dislocation Dynamic (DD) codes. A Synchronous parallel Kinetic Monte Carlo code was developed and tested which promises to expand the range of applicability of kMC simulations. This LDRD furthered the limits of the available science on the thermodynamic and mechanic behavior of metallic alloys and extended the application of physically-based multiscale materials modeling to cases of severe temperature and neutron fluence conditions in advanced future nuclear reactors. The report is organized as follows: after a brief introduction, we present the research activities, and results obtained. We give recommendations on future LLNL activities that may contribute to the progress in this area, together with examples of possible research lines to be supported.

36 MATERIALS SCIENCE↗