Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source code (Computer science)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Design and implementation of a 150 GHz single-channel millimeter wave interferometer on Joint TEXT tokamak

A simple, single-channel millimeter-wave interferometer system has been designed, fabricated, and installed on the J-TEXT tokamak. For the plasma density anticipated on J-TEXT, a solid-state source operating at 150 GHz has been chosen to minimize errors due to both vibration along the beam path and refraction in the plasma. The new aspect of the interferometer design is to use a subharmonic mixer for detection with a frequency doubled 150 GHz source. It employs a single source which is bias-tuned and modulated with a sawtooth wave form up to 100 kHz in order to generate the intermediate frequency. The 12.5 GHz voltage-controlled oscillator is multiplied to 75 GHz before a final doubler raises it to 150 GHz. A portion of the 75 GHZ power is used for the local oscillator (LO) and is directly connected to the LO input of the subharmonic mixer. The phase is evaluated by a digital phase comparator using a software-based algorithm. Detection noise limits the minimum resolvable phase change with the interferometer to {+-}0.05 fringe, which corresponds to an averaged electron density change along the chord of {+-}1.1 Multiplication-Sign 10{sup 17} m{sup -2}. The maximum measurable electron density is expected to be {approx}9 Multiplication-Sign 10{sup 19} m{sup -3}. A comparison of preliminary results from the millimeter wave interferometer with that from the far-infrared hydrogen cyanide laser (wavelength of 337 {mu}m) interferometer shows good agreement during the pulse flat-top period. The millimeter wave interferometer system will be used as a part of the density feedback control system in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Treatment planning of a skin-sparing conical breast brachytherapy applicator using conventional brachytherapy software

Purpose: AccuBoost is a noninvasive image-guided technique for the delivery of partial breast irradiation to the tumor bed and currently serves as an alternate to conventional electron beam boost. To irradiate the target volume while providing dose sparing to the skin, the round applicator design was augmented through the addition of an internally truncated conical shield and the reduction of the source to skin distance. Methods: Brachytherapy dose distributions for two types of conical applicators were simulated and estimated using Monte Carlo (MC) methods for radiation transport and a conventional treatment planning system (TPS). MC-derived and TPS-generated dose volume histograms (DVHs) and dose distribution data were compared for both the conical and round applicators for benchmarking purposes. Results: Agreement using the gamma-index test was {>=}99.95% for distance to agreement and dose accuracy criteria of 2 mm and 2%, respectively. After observing good agreement, TPS DVHs and dose distributions for the conical and round applicators were obtained and compared. Brachytherapy dose distributions generated using Pinnacle{sup 3} for ten CT data sets showed that the parallel-opposed beams of the conical applicators provided similar PTV coverage to the round applicators and reduced the maximum dose to skin, chest wall, and lung by up to 27%, 42%, and 43%, respectively. Conclusions: Brachytherapy dose distributions for the conical applicators have been generated using MC methods and entered into the Pinnacle{sup 3} TPS via the Tufts technique. Treatment planning metrics for the conical AccuBoost applicators were significantly improved in comparison to those for conventional electron beam breast boost.

60 APPLIED LIFE SCIENCES↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials (Second Annual Progress Report)

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Thermal tomography (TT) provides a capability for non-destructive evaluation of sub-surface defects in arbitrary size structures. Thermal tomography is a computational method for heat diffusion-based imaging of solids, which provides 3D visualization of data from flash thermography measurements. We investigate thermal tomography imaging and nondestructive evaluation of stainless steel and nickel super alloy metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing (AM) process. Metallic structures produced with LPBF contain defects, and there are limited capabilities to evaluate these structures non-destructively. Thermal tomography reconstruction of 3D apparent spatial effusivity provides information about AM structure geometry and internal material flaws. We study performance of thermal tomography in imaging of metallic structures through COMSOL computer simulations of transient heat transfer, and through reconstruction of data obtained from experimental measurements. Reconstruction of internal defects is investigated using a stainless steel 316L specimen with flat bottom hole (FBH) indentations, and Inconel 718 plate produced with laser powder bed fusion (LPBF) method, which contains imprinted hemispherical shape low density regions containing non-sintered metallic powder. The FBH’s have the same sizes as the imprinted defects in the LPBF specimens, but offer better imaging contrast. Thermal tomography reconstructions provide visualizations of internal defects, and allow for estimation of their sizes and locations. Detection sensitivity of TT is limited by noises. We investigate separation of signal from noise in thermography images using several machine learning (ML) methods, including new spatio-temporal blind source separation (STBSS) and spatio-temporal sparse dictionary learning (STSDL) methods. Performance of the ML methods is benchmarked using thermography data obtained from imaging stainless steel 316L and Inconel 718 specimens produced LPBF method with imprinted calibrated porosity defects. The ML methods are ranked by F-score and execution runtime. Finally, we investigate TT of AM stainless steel 316L specimen with imprinted internal porosity defects using relatively low-cost, small form factor infrared (IR) camera based on uncooled micro bolometer detector. Sparse coding related K-means singular value decomposition (SVD) machine learning, image processing algorithms are developed to improve quality of TT images through removal of Additive white Gaussian noise without blurring the images. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact TT can also be used for in-service nondestructive evaluation (NDE). With capability to perform in-service NDE of the AM component lifecycle, TT data can be used for development of a component digital twin.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-I-10: Automatic Monitoring of Accumulated Dose Indices From DICOM RDSR to Improve Radiation Safety in X-Ray Angiography

Purpose: To investigate the potential benefits of automatic monitoring of accumulated patient and staff dose indicators, i.e., CAK and KAP, from DICOM Radiation Dose Structured Reports (RDSR) in x-ray angiography (XA). Methods: Recently RDSR has enabled the convenient aggregation of dose indices and technique parameters for XA procedures. The information contained in RDSR objects for three XA systems, dedicated to different types of clinical procedures, has been collected and aggregated in a database for over one year using a system developed with open-source software at the Karolinska University Hospital. Patient weight was complemented to the RDSR data via an interface with the Hospital Information System (HIS). Results: The linearly approximated trend in KAP over a time period of a year for cerebrovascular, pelvic/peripheral vascular, and cardiovascular procedures showed a decrease of 12%, 20%, and 14%, respectively. The decrease was mainly due to hardware/software upgrades and new low-dose imaging protocols, and partially due to ongoing systematic radiation safety education of the clinical staff. The CAK was in excess of 3 Gy for 15 procedures, and exceeded 5 Gy for 3 procedures. The dose indices have also shown a significant dependence on patient weight for cardiovascular and pelvic/peripheral vascular procedures; a 10 kg shift in mean patient weight can result in a dose index increase of 25%. Conclusion: Automatic monitoring of accumulated dose indices can be utilized to notify the clinical staff and medical physicists when the dose index has exceeded a predetermined action level. This allows for convenient and systematic follow-up of patients in risk of developing deterministic skin injuries. Furthermore, trend analyses of dose indices over time is a valuable resource for the identification of potential positive or negative effects (dose increase/decrease) from changes in hardware, software, and clinical work habits.

60 APPLIED LIFE SCIENCES↗

WE-G-204-09: Medical Physics 2.0 in Practice: Automated QC Assessment of Clinical Chest Images

Purpose: To determine whether a proposed suite of objective image quality metrics for digital chest radiographs is useful for monitoring image quality in our clinical operation. Methods: Seventeen gridless AP Chest radiographs from a GE Optima portable digital radiography (DR) unit (Group 1), seventeen (routine) PA Chest radiographs from a GE Discovery DR unit (Group 2), and sixteen gridless (non-routine) PA Chest radiographs from the same Discovery DR unit (Group 3) were chosen for analysis. Groups were selected to represent “sub-standard” (Group 1), “standard-of-care” (Group 2), and images with a gross technical error (Group 3). Group 1 images were acquired with lower kVp (90 vs. 125), shorter source-to-image distance (127cm vs 183cm) and were expected to have lower quality than images in Group 2. Group 3 was expected to have degraded contrast versus Group 2.This evaluation was approved by the institutional Quality Improvement Assurance Board (QIAB). Images were anonymized and securely transferred to the Duke University Clinical Imaging Physics Group for analysis using software previously described{sup 1} and validated{sup 2}. Image quality for individual images was reported in terms of lung grey level(Lgl); lung noise(Ln); rib-lung contrast(RLc); rib sharpness(Rs); mediastinum detail(Md), noise(Mn), and alignment(Ma); subdiaphragm-lung contrast(SLc); and subdiaphragm area(Sa). Metrics were compared across groups. Results: Metrics agreed with published Quality Consistency Ranges with three exceptions: higher Lgl, lower RLc, and SDc. Higher bit depth (16 vs 12) accounted for higher Lgl values in our images. Values were most internally consistent for Group 2. The most sensitive metric for distinguishing between groups was Mn followed closely by Ln. The least sensitive metrics were Md and RLc. Conclusion: The software appears promising for objectively and automatically identifying substandard images in our operation. The results can be used to establish local quality consistency ranges and action limits per facility preferences.

60 APPLIED LIFE SCIENCES↗

Comparison of ADVANTG Simulations to Simple Shielding Measurements - Paper 36

Monte Carlo (MC) radiation transport simulations, like those performed using Monte Carlo N-Particle (MCNP), can be highly accurate but require time to reduce the statistical uncertainties in the calculated detector response(s). Many different 'variance reduction' techniques devised over the years increase the efficiency of MC calculations, but these methods can be more art than science. Many of these methods are problem specific or require careful tuning of parameters for good performance. One of the best variance reduction methods, in terms of both reliable performance increases and ease of use, is the use of weight windows. Weight windows are derived from an importance map in space and energy that allows the transport code to focus more simulation time on particles that have a higher likelihood of being important to the final detector response. Less time is spent simulating particles that have little chance of making a contribution to the detector response. MCNP already includes the abilities to generate and use weight windows. Unfortunately, generating weight windows can take a very long time, perhaps longer than the original problem. Oak Ridge National Laboratory has led the development of hybrid methods using a discrete ordinates adjoint calculation to quickly develop an importance map (weight windows) for use in a Monte Carlo code. The Consistent Adjoint Driven Importance Sampling (CADIS) method uses an adjoint calculation to develop both an importance map and a biased source distribution that work together. This method is reasonably automatic, is easy to use, and has been implemented in the Automated Variance reduction Generator (ADVANTG) package that works with MCNP5. ADVANTG reads an MCNP input file and a small amount of extra user information and then runs an adjoint deterministic calculation using Denovo. The importance map and biased source distribution derived from the CADIS method can then be incorporated back into the original MCNP input file to enhance the figure-of-merit (FOM) of the calculation. The FOM is a measure of the efficiency of the calculation using the amount of run time and corresponding level of statistical uncertainty in the detector result. ADVANTG-enhanced MCNP input files have been shown to increase the FOM of many types of problems, obtaining the same level of statistical uncertainty in a shorter time compared to standard MCNP. ADVANTG can also generate variance reduction parameters (importance map and biased source) using the Forward-Weighted CADIS (FW-CADIS) method for optimizing mesh tallies. The CADIS method creates variance reduction parameters that optimize a tally's total quantity (flux, dose rate, interaction rate, etc.) and will not generally increase performance for all parts of a segmented tally. To optimize a segmented tally, the FW-CADIS method uses two discrete ordinates calculations to make variance reduction parameters that help compute a segmented tally with uniform relative uncertainties in each bin. This report will demonstrate that using ADVANTG for neutron and photon radiation shielding problems will (1) preserve the standard MCNP results and (2) obtain those results either with less statistical uncertainty or in shorter times than the standard MCNP calculation. The four demonstration problems in this report are based on simple neutron or photon transmission measurements through different materials. All of the problems here used the CADIS method and still saw improvement across the flux tallies segmented by particle energy. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Large Scale Laser Two-Photon Polymerization Structuring for Fabrication of Artificial Polymeric Scaffolds for Regenerative Medicine

We present a femtosecond Laser Two-Photon Polymerization (LTPP) system of large scale three-dimensional structuring for applications in tissue engineering. The direct laser writing system enables fabrication of artificial polymeric scaffolds over a large area (up to cm in lateral size) with sub-micrometer resolution which could find practical applications in biomedicine and surgery. Yb:KGW femtosecond laser oscillator (Pharos, Light Conversion. Co. Ltd.) is used as an irradiation source (75 fs, 515 nm (frequency doubled), 80 MHz). The sample is mounted on wide range linear motor driven stages having 10 nm sample positioning resolution (XY--ALS130-100, Z--ALS130-50, Aerotech, Inc.). These stages guarantee an overall travelling range of 100 mm into X and Y directions and 50 mm in Z direction and support the linear scanning speed up to 300 mm/s. By moving the sample three-dimensionally the position of laser focus in the photopolymer is changed and one is able to write complex 3D (three-dimensional) structures. An illumination system and CMOS camera enables online process monitoring. Control of all equipment is automated via custom made computer software ''3D-Poli'' specially designed for LTPP applications. Structures can be imported from computer aided design STereoLihography (stl) files or programmed directly. It can be used for rapid LTPP structuring in various photopolymers (SZ2080, AKRE19, PEG-DA-258) which are known to be suitable for bio-applications. Microstructured scaffolds can be produced on different substrates like glass, plastic and metal. In this paper, we present microfabricated polymeric scaffolds over a large area and growing of adult rabbit myogenic stem cells on them. Obtained results show the polymeric scaffolds to be applicable for cell growth practice. It exhibit potential to use it for artificial pericardium in the experimental model in the future.

36 MATERIALS SCIENCE↗

SU-E-T-65: Characterization of a 2D Array for QA and Pretreatment Plan Verification

Purpose: The OCTAVIUS detector729 is a 2D array of 729 air vented cubic plane parallel ion chambers used for pretreatment verification and QA. In this study we investigated dosimetric characteristics of this system for clinical photon beam dosimetry. Methods: Detector performance evaluation included determination of the location of the effective point of measurement (EPM), sensitivity, linearity, and reproducibility of detector response, as well as output factor, dose rate, and source to surface distance (SSD) dependence. Finally, assessment of wedge modulated fields was carried out. All the evaluations were performed five times for low and high photon energies. For reference measurements, a 0.6 cc ionization chamber was used. Data analysis and comparison of the OCTAVIUS detector with reference ion chamber data was performed using the VeriSoft patient plan verification software. Results: The reproducibility and stability of the measurements are excellent, the detector showed same signal with a maximum deviation of less than 0.5% in short and long term. Results of sensitivity test showed same signal with a maximum deviation of approximately 0.1%. As the detector 729 response is linear with dose and dose rate, it can be used for the measurement at regions of high dose gradient effectively. The detector agrees with the ionization chamber measurement to within 1% for SSD range of 75 to 125 cm. Also, its measured wedge modulated profiles matched very well with ion chamber dose profiles acquired in a water tank. Conclusions: As the response of the detector 729 is linear with dose and dose rate, it can be used for the measurements in the areas of dose gradients effectively. Based on the measurements and comparisons performed, this system is a reliable and accurate dosimeter for QA and pretreatment plan verification in radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-302: Implementation of the RadCalc Image Analysis Tool for IMRT QA

Purpose: To assess RadCalc as a means for analyzing fluence maps of IMRT QA patient plans. Eclipse generated fluence maps were compared to RadCalc fluence maps generated from both Eclipse parameters and from dynalog trajectory files. Methods: Six IMRT plans consisting of fifty individual fields were compared both field-by-field and as composite plans. These plans were exported from Eclipse to RadCalc. Each plan was then delivered in QA mode on a Varian Clinac iX, while recording and saving the dynalog trajectory files. These files were then imported into RadCalc, providing three sources of generating fluence maps: Eclipse, RadCalc, and dynalog files. Using the image analysis tool in RadCalc, a gamma analysis was then performed as a point-by-point comparison for each IMRT field. The Eclipse fluence map was used as the baseline for each comparison. Results: Based on the manufacturer’s recommendations, all fields were normalized to the maximum pixel value within each Eclipse field. All data was analyzed using a gamma index of 3mm/3% with passing criteria of 90%. For both dynalog analysis and RadCalc fluence analysis, 48/50 created fluence maps passed at greater than 90% when compared with the Eclipse baseline. In analyzing the composite of each of the six patients’ plans, all plans passed over 90%. Conclusion: Using the dynalog trajectory files in combination with RadCalc Version 6.3 image analysis is a promising metric for verifying IMRT QA passing rates. Notably, if a field failed, it did so for both dynalog and RadCalc compared to Eclipse. This suggests RadCalc can accurately simulate fluence maps, with similar results to dynalog comparisons. Limitations within the RadCalc software were discovered in the analytical process such as pixel resolution and the inability to set minimum threshold values. Comparisons could be extended to include dose map and distance to agreement analysis by expanding software capabilities.

60 APPLIED LIFE SCIENCES↗

Novel Deployment of Elpasolites as a Dual Neutron/Gamma-Ray Directional Detector

At a time when upholding national security has never been more important, there exists a need for the advancement of radiation detection technologies. Neutron and photon detectors are essential to fulfilling mission areas including detection and localization of missing, stolen or smuggled radiological or nuclear materials, quantification of the effects of a radiological or nuclear event, and supporting nonproliferation efforts. The aim of this study was to evaluate a new radiation detector based on the scintillation elpasolite compound Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous measurements of neutron and photon flux and the localization of radiation sources. Previous studies performed on the CLYC scintillator indicate its potential for thermal neutron and gamma-ray measurements. This study is dedicated to the novel application of the CLYC as a dual neutron / photon detector and as part of a directional detection system. Both computational modeling and an experimental study were carried out within this research project. As part of the computational study, the response of a CLYC scintillator detector to gamma rays induced by thermal neutron interaction with Cl and 7 Li nuclei was investigated using the MCNP6 code. In addition, arrays of three and four CLYC detectors were modeled in order to evaluate the directional detection of both a thermal neutron source and a gamma-ray source. It was shown that little or no quality of source direction determination would be lost when three detectors were used in the array compared to four detectors. In the experimental study, the photon spectroscopy capabilities of the CLYC detectors were evaluated. A gamma-ray energy resolution of 4.9% was measured for the 662-keV peak of 137 Cs and 3.6% for the 1.33-MeV peak of 60 Co. Using a thermal neutron source, the pulse shape discrimination analysis was successfully performed for the CLYC detector signal waveforms. Thermal neutrons and gamma rays were separated with an exceptional figure of merit (FOM) of 2.3. An array of three CLYC detectors was assembled for the purpose of directional neutron / gamma-ray detection. The intrinsic peak efficiency of CLYC detectors was evaluated. The three-CLYC detector array was deployed for directional measurements with a single gamma-ray 137 Cs source, two gamma-ray sources of 137 Cs and 60 Co isotopes and a thermal neutron source designed using a 239PuBe neutron source supplied with a polyethylene moderator. Measurements were carried out using sources located in the longitude and latitude planes over the angles from 0° to 360°. The measured data were processed through a maximum likelihood estimation algorithm providing a possible direction for which the radioactive source in each case was positioned. The estimated directions were close if not exact matches for the actual directions to the radioactive source. The largest discrepancy in direction produced by the algorithm was approximately 11%. However, it was hypothesized that this percent error can be decreased by homogenizing the directional detection system to consist of scintillators of the same size and quality, identical photomultiplier tubes and identical aluminum housings. The feasibility of this hypothesis to decrease the percent error was confirmed by the zero percent error achieved in the directional measurements produced in the computational study utilizing a homogenous directional detection system. The results of computational and experimental studies completed within this research project provide means to propose the array of three CLYC scintillators as an efficient dual neutron / gamma-ray directional detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ADVANTG Results for a Proposed NDA System for Detecting Pin Diversion from SNF - Paper 120

This summary describes the results of applying the ADVANTG variance reduction parameter generator to accelerate continuous-energy Monte Carlo simulations of the {sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection system proposed by Hu et al. for detecting the diversion of fuel elements from spent nuclear fuel (SNF) assemblies. In previous work, ADVANTG was applied to a suite of nine radiation detection, special nuclear material (SNM) movement detection, and safeguards test cases. That effort demonstrated that ADVANTG was able to provide large increases in tally figures of merit (FOMs) in nearly all of the cases without introducing bias into the Monte Carlo results. The objective of the work described here is to further evaluate ADVANTG, and also to identify gaps in capability with regard to nuclear safeguards applications, by applying the code to a challenging problem that is of a different nature from the ones previously studied. The CIPN nondestructive assay (NDA) system consists of three fission chambers embedded in a C-shaped block of polyethylene and a polyethylene-moderated {sup 252}Cf source that are placed on opposite sides of a subject SNF assembly. The idea of the detection system is to measure the difference between the background neutron count rate, due to spontaneous fission in the fuel material, and the count rate observed once the source is introduced, which is dominated by multiplication within the assembly. Based on the difference between these count rates, the fissile content of the assembly can be inferred, and this information can be used to determine if some fraction of the original fuel pins have been replaced with depleted uranium substitutes. The authors report that the system can detect the replacement of at least eight pins (3% of total mass). The ADVANTG code generates space- and energy-dependent weight-window bounds and biased source distributions based on approximate transport solutions that are efficiently generated by the Denovo 3-D discrete ordinates package. ADVANTG implements the Consistent Adjoint Driven Importance Sampling (CADIS) method for accelerating individual tallies and the Forward-Weighted CADIS (FW-CADIS) method for obtaining relatively uniform uncertainties across tallies over multiple regions and/or energy bins. The variance reduction parameters are generated in a format directly usable by standard versions of MCNP5 and MCNPX. In this work, the ADVANTG variance reduction parameter generator was applied to accelerate continuous energy MCNPX simulations of the {sup 252}Cf Interrogation with Prompt Neutron detection system for detecting the diversion of fuel elements from SNF assemblies. Variance reduction parameters generated with the existing version of ADVANTG actually slowed down tally convergence in all cases. The cause of the poor performance was found to be the lack of an induced fission source treatment in the fixed-source discrete ordinates calculations employed by ADVANTG. Because fission was treated as capture and not as a source, the importance maps generated by ADVANTG significantly underestimated the importance of thermal neutrons in and around the fuel elements. In order to obtain improved results, we developed an experimental implementation of a fission source outer iteration for the adjoint calculations. We used this prototype capability to generate new variance reduction parameters and found that the mean fission rates agreed well with those predicted by the conventional MCNPX simulations, as was expected. With these new parameters, speedup factors of 59 to 80 were obtained for the case with the background source, and factors of 17 to 24 were obtained for the cases with the interrogating source. These results demonstrate that a fission source treatment is needed to improve the effectiveness of ADVANTG in problems where the effects of induced fission are important. This includes many types of NDA problems that are relevant to safeguards applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transport Test Problems for Radiation Detection Scenarios

Modeling forms an important component of radiation detection development, allowing for testing of new detector designs, evaluation of existing equipment against a wide variety of potential threat sources, and assessing operation performance of radiation detection systems. This can, however, result in large and complex scenarios which are time consuming to model. A variety of approaches to radiation transport modeling exist with complementary strengths and weaknesses for different problems. This variety of approaches, and the development of promising new tools (such as ORNL’s ADVANTG) which combine benefits of multiple approaches, illustrates the need for a means of evaluating or comparing different techniques for radiation detection problems. This report presents a set of 9 test problems for comparing different types of radiation transport calculations, identifying appropriate tools for classes of problems, and testing and guiding the development of new methods. Cases are drawn primarily from existing or previous calculations with a preference for cases which include experimental data, or otherwise have results with a high level of confidence, are non-sensitive, and represent problem sets of interest to NA-22. From a technical perspective, cases are chosen to span a range of difficulty and to include gamma transport, neutron transport, or both and represent different important physical processes and a range of sensitivity to angular or energy fidelity. Following test case identification, existing information about geometry, measurements, and previous calculations were assembled. Monte Carlo results (MCNP decks) were reviewed or created and re-run in order to attain accurate computational times and to verify agreement with experimental data, when present. Test case information was then conveyed to ORNL in order to guide testing and development of hybrid calculations. The results of those ADVANTG calculations were then sent to PNNL for compilation. This is a report describing the details of the selected test cases and results from available transport codes. Additional results from other transport codes will be added during the next year, along with additional cases if needed for software testing. Future work will extend the test problems to include more extensive cross-code comparisons as well as more refined metrics for evaluating the tradeoffs between operator time, computational time, and solution accuracy, to assemble a formalized benchmark set.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Epp: A C++ EGSnrc user code for x-ray imaging and scattering simulations

Purpose: Easy particle propagation (Epp) is a user code for the EGSnrc code package based on the C++ class library egspp. A main feature of egspp (and Epp) is the ability to use analytical objects to construct simulation geometries. The authors developed Epp to facilitate the simulation of x-ray imaging geometries, especially in the case of scatter studies. While direct use of egspp requires knowledge of C++, Epp requires no programming experience. Methods: Epp's features include calculation of dose deposited in a voxelized phantom and photon propagation to a user-defined imaging plane. Projection images of primary, single Rayleigh scattered, single Compton scattered, and multiple scattered photons may be generated. Epp input files can be nested, allowing for the construction of complex simulation geometries from more basic components. To demonstrate the imaging features of Epp, the authors simulate 38 keV x rays from a point source propagating through a water cylinder 12 cm in diameter, using both analytical and voxelized representations of the cylinder. The simulation generates projection images of primary and scattered photons at a user-defined imaging plane. The authors also simulate dose scoring in the voxelized version of the phantom in both Epp and DOSXYZnrc and examine the accuracy of Epp using the Kawrakow-Fippel test. Results: The results of the imaging simulations with Epp using voxelized and analytical descriptions of the water cylinder agree within 1%. The results of the Kawrakow-Fippel test suggest good agreement between Epp and DOSXYZnrc. Conclusions: Epp provides the user with useful features, including the ability to build complex geometries from simpler ones and the ability to generate images of scattered and primary photons. There is no inherent computational time saving arising from Epp, except for those arising from egspp's ability to use analytical representations of simulation geometries. Epp agrees with DOSXYZnrc in dose calculation, since they are both based on the well-validated standard EGSnrc radiation transport physics model.

60 APPLIED LIFE SCIENCES↗

Parametric Optimization of Undulators for NSLS-II Project Beamlines

General optimization procedure, computation methods used, and the obtained optimal parameters of undulators for the NSLS-II project beamlines are reported. The optimization starts with high-accuracy calculation of undulator magnetic fields, using Radia magnetostatics code, for a large set of periods and vertical gaps of a given undulator type, given magnetic materials and a scalable magnet geometry. From the resulting magnetic fields, a sub-set of undulator periods and the corresponding vertical gaps, providing the required low-energy cut-off values of spectral harmonics for each particular beamline, is determined. In parallel, from the same Radia undulator models, angular magnetic kick maps are calculated, and the insertion device effect on electron beam is simulated using Tracy-2 tracking code based on symplectic integrator. After these simulations, magnet parameters are fine-tuned and the maximal acceptable undulator lengths are determined for different straight sections, as functions of minimal gap and with due regard for the electron beam vertical ''stay clear'' constraint in the case of in-vacuum undulators. Finally, the optimal undulator period and length are determined as the values providing maximal spectral flux among the pre-selected undulator cases, already satisfying the requirements concerning the harmonic cut-off values and the effect on electron beam.

43 PARTICLE ACCELERATORS↗

Shock-Induced Solid-State Reactions in Powders: An Experimentally-Based Reassessment

We have performed a series of ten planar impact experiments on six different materials, including certain reactive powders and two inert materials, using Sandia's 89 - mm powder gun at the STAR facility. Time - resolved particle - velocity histories were determined during each of the experiments from one or more VISAR measurements. We have analyzed the results of these measurements 1) by using jump conditions to determine shock and first reshock states and 2) by comparing measured particle velocity histories to synthetic histories predicted by one - dimensional computational analyses using the CTH shock physics code with various models for inert and reactive materials . These comparisons are consistent with the conclusion for these particular reactive powders, that for the duration of shock loading either 1) there is insignificant reaction or 2) the products of any reaction are indistinguishable from the reactants under the experimental conditions. Shock and reshock states were extracted for shock pressures between 5 and 40 GPa. Densities were at or greater than the theoretical maximum zero - pressure density of the starting mixture. This result would be expected if there were no reaction or negligible reaction for the first two shock states. Two experiments were performed on one reactive powder in a "ring - down " geometry to look for evidence of vapor production on pressure release. In both cases, the measured velocity continued to increase slowly over a period of microseconds for the du ration of the experiment. This observation suggests that vapor is produced along the release path, but information about the mechanism for vapor production cannot be extracted from these data. While it is possible that vapor is produced by a shock - induced reaction involving more than one of the original constituents, a simpler interpretation is that the vapor is made up of products of shock - induced decomposition reactions and/or simple vaporization of the constituents as would be expected to take place under the conditions of these experiments. Other sources of vapor could be water adsorbed on grain surfaces and air originally in the voids. Thus it is not necessary to invoke significant recombination reactions to explain the data. However, in the absence of ring - down control experiments, the possibility remains open. These conclusions are different from those of previous workers, but reassessment of a subset of the earlier data yields results consistent with the present work, i.e., the shock compression data do not provide evidence for strong exothermic reactions.

36 MATERIALS SCIENCE↗

MOOSE-based Tritium Migration Analysis Program, Version 8 (TMAP8) for advanced open-source tritium transport and fuel cycle modeling

Tritium management is critical for the safety, sustainability, and economics of fusion energy systems, and advanced and reliable modeling tools help accelerate the development of tritium technologies. This paper presents the Tritium Migration Analysis Program, Version 8 (TMAP8), an open-source, MOOSE-based application developed to provide state-of-the-art tritium transport and fuel cycle modeling capabilities. TMAP8 aims to expand the capabilities of previous versions (i.e., TMAP4 and TMAP7) by leveraging modern computational techniques, ensuring high software quality assurance standards (key to building trust), and enabling multispecies, multiscale, and multiphysics simulations for integrated tritium transport modeling in complex geometries. This paper outlines TMAP8’s scope and rigorous development practices, emphasizing its transparency, accessibility, modularity, and reliability. We present the current suite of verification and validation cases based on those from TMAP4, demonstrating TMAP8’s accuracy and reliability against analytical solutions and experimental data. Additionally, the paper showcases TMAP8’s integrated fuel cycle modeling capabilities, highlighting its applicability at various scales and levels. The TMAP8 code and documentation are openly available, promoting collaborative development and widespread adoption within the fusion community. Future work will soon expand TMAP8’s verification and validation suite to include those from TMAP7 and other recent experimental studies for validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analyzing and Exploring Training Recipes for Large-Scale Transformer-Based Weather Prediction

Abstract The rapid rise of deep learning (DL) in numerical weather prediction (NWP) has led to a proliferation of models which forecast atmospheric variables with comparable or superior skill than traditional physics-based NWP. However, among these leading DL models, there is a wide variance in both the training settings and architecture used. Further, the lack of thorough ablation studies makes it hard to discern which components are most critical to success. In this work, we show that it is possible to attain high forecast skill even with relatively off-the-shelf architectures, simple training procedures, and moderate compute budgets. Specifically, we train a minimally modified Swin Transformer V2 (SwinV2) on ERA5 data and find that it attains superior skill in terms of mean-square errors of deterministic forecasts when compared against the European Centre for Medium-Range Weather Forecasts’ Integrated Forecasting System (IFS). Almost all DL–NWP systems share a core set of hyperparameters and design decisions. To aid and expedite future DL–NWP research, we present an in-depth, systematic exploration of different loss functions, model sizes and depths, patch sizes, and multistep training objectives. We also examine the model performance with metrics beyond the typical accuracy (ACC) and RMSE and investigate how the performance scales with model size. Through our open-source code, scoring pipelines, and models, we share our findings on key aspects of the training pipeline. These ablations reduce the necessity for expensive hyperparameter tuning and lower the barrier to entry for future DL–NWP research. Significance Statement This study investigates the potential of using large-scale transformer-based models for weather prediction, showing that it is possible to achieve high forecast accuracy with simpler, off-the-shelf architectures. By training a minimally modified SwinV2 transformer on ERA5 data, we show that the model achieves competitive forecast skill in terms of mean-square error for key variables, outperforming the European Centre for Medium-Range Weather Forecasts’ Integrated Forecasting System (IFS) at all lead times. Our findings suggest that effective training strategies, such as multistep fine-tuning and channel-weighted losses, significantly enhance the model’s performance. However, we also highlight that these improvements come with trade-offs in other areas, such as ensemble spread and high-frequency spatial detail. This work highlights the promise of deep learning in improving weather forecasts, which could lead to better preparedness and response to weather events, ultimately benefiting society by providing more reliable weather predictions.

Willard, Jared D. [Lawrence Berkeley National Labo↗

SU-F-18C-10: Clinical Implementation of Radiochromic Film Based CTDI Measurements

Purpose: To evaluate accuracy and reproducibility of a radiochromic film-based protocol to measure computer tomography dose index (CTDI) as a part of annual QA on CT scanners and kV CBCT systems attached to linear accelerators. Methods: Energy dependence of Gafchromic XR-QA2(R) film model was tested over imaging beam qualities (50 – 140 kVp). Film pieces were irradiated in air to known values of air kerma in air (up to 10 cGy). Change in film reflectance was determined with an in-house written code using images produced by a flatbed document scanner. Calibration curves for each beam quality were created, and film responses for same air-kerma values were compared.Sets of film strips were placed into holes of a CTDI phantom and irradiated for several clinical scanning protocols on CT-simulators and CBCT systems. Film reflectance change was converted into dose to water and used to calculate CTDIvol values. Measured CTDIvol values were compared to tabulated CTDIvol values. Results: Average variations of ±5.2% in the mean film reflectance change were observed in the energy range of 80 to 140 keV, and 11.1% between 50 and 140 keV. The averaged measured CTDI values presented a mean variation for the same machine and protocol of 2.6%. However, measured CTDI values were in average 10% lower than tabulated CTDI values for CT-simulators, and 44% higher for CBCT systems. Conclusion: We found that in relatively broad range of beam qualities used in diagnostic radiology variation of film response is within ±5% resulting in ±15% systematic error in dose estimates if a single calibration curve is used. Relatively large discrepancy between measured and tabulated CTDI values for different protocols and imaging systems used within radiotherapy department strongly support the trend towards replacing CTDI value with equilibrium dose measurement in the center of cylindrical phantom as suggested by TG-111. This work was supported by the Natural Sciences and Engineering Research Council of Canada, Contract No. 386009; Partial support by CREATE, Medical Physics Research Training Network grant of the Natural Science and Engineering Research Council, Contract No. 432290.

07 ISOTOPE AND RADIATION SOURCES↗