Search NASA⌕ Search

SEARCH · Search NASA

Results for “Strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

SU-D-BRE-06: Modeling the Dosimetric Effects of Volumetric and Layer-Based Repainting Strategies in Spot Scanning Proton Treatment Plans

Purpose: To compare multiple repainting techniques as strategies for mitigating the interplay effect in free-breathing, spot scanning proton plans. Methods: An analytic routine modeled three-dimensional dose distributions of pencil-beam proton plans delivered to a moving target. The interplay effect was studied in subsequent calculations by modeling proton delivery from a clinical synchrotron based spot scanning system and respiratory target motion, patterned from surrogate breathing traces from clinical 4DCT scans and normalized to nominal 0.5 and 1 cm amplitudes. Two distinct repainting strategies were modeled. In idealized volumetric repainting, the plan is divided up and delivered multiple times successively, with each instance only delivering a fraction of the total MU. Maximum-MU repainting involves delivering a fixed number of MU per spot and repeating a given energy layer until the prescribed MU are reached. For each of 13 patient breathing traces, the dose was computed for up to four volumetric repaints and an array of maximum-MU values. Delivery strategies were inter-compared based on target coverage, dose homogeneity, and delivery time. Results: Increasing levels of repainting generally improved plan quality and reduced dosimetric variability at the expense of longer delivery time. Motion orthogonal to the scan direction yielded substantially greater dose deviations than motion parallel to the scan direction. For a fixed delivery time, maximum-MU repainting was most effective relative to idealized volumetric repainting at small maximum-MU values. For 1 cm amplitude motion orthogonal to the scan direction, the average homogeneity metric (D5 – D95)[%] of 23.4% was reduced to 7.6% with a 168 s delivery using volumetric repainting compared with 8.7% in 157.2 s for maximum-MU repainting. The associated static target homogeneity metric was 2.5%. Conclusion: Maximum-MU repainting can provide a reasonably effective alternative to volumetric repainting for systems without the capability to switch energies rapidly.

60 APPLIED LIFE SCIENCES↗

SU-E-T-500: Dose Escalation Strategy for Lung Cancer Patients Using a Biologically- Guided Target Definition

Purpose: Dose escalation strategy for lung cancer patients can lead to late symptoms such as pneumonitis and cardiac injury. We propose a strategy to increase radiation dose for improving local tumor control while simultaneously striving to minimize the injury of organs at risk (OAR). Our strategy is based on defining a small, biologically-guided target volume for receiving additional radiation dose. Methods: 106 patients with lung cancer treated with radiotherapy were selected for patients diagnosed with stage II and III disease. Previous research has shown that 50% of the maximum SUV threshold in FDG-PET imaging is appropriate for delineation of the most aggressive part of a tumor. After PET- and CT-derived targets were contoured, an IMRT treatment plan was designed to deliver 60 Gy to the GTV as delineated on a 4D CT (Plan 1). A second plan was designed with additional dose of 18 Gy to the PET-derived volume (Plan 2). A composite plan was generated by the addition of Plan 1 and Plan 2. Results: Plan 1 was compared to the composite plan and increases in OAR dose were assessed. For seven patients on average, lung V5 was increased by 1.4% and V20 by 4.2% for ipsilateral lung and by 13.5% and 7% for contralateral lung. For total lung, V5 and V20 were increased by 4.5% and 4.8% respectively. Mean lung dose was increased by 9.7% for the total lung. The maximum dose to the spinal cord increased by 16% on average. For the heart, V20 increased by 4.2% and V40 by 5.2%. Conclusion: It seems feasible that an additional 18 Gy of radiation dose can be delivered to FDG PET-derived subvolume of the CT-based GTV of the primary tumor without significant increase in total dose to the critical organs such as lungs, spinal cord and heart.

60 APPLIED LIFE SCIENCES↗

SU-F-BRF-07: Impact of Different Patient Setup Strategies in Adaptive Radiation Therapy with Simultaneous Integrated Volume-Adapted Boost of NSCLC

Purpose: To evaluate the potential impact of several setup error correction strategies on a proposed image-guided adaptive radiotherapy strategy for locally advanced lung cancer. Methods: Daily 4D cone-beam CT and weekly 4D fan-beam CT images were acquired from 9 lung cancer patients undergoing concurrent chemoradiation therapy. Initial planning CT was deformably registered to daily CBCT images to generate synthetic treatment courses. An adaptive radiation therapy course was simulated using the weekly CT images with replanning twice and a hypofractionated, simultaneous integrated boost to a total dose of 66 Gy to the original PTV and either a 66 Gy (no boost) or 82 Gy (boost) dose to the boost PTV (ITV + 3mm) in 33 fractions with IMRT or VMAT. Lymph nodes (LN) were not boosted (prescribed to 66 Gy in both plans). Synthetic images were rigidly, bony (BN) or tumor and carina (TC), registered to the corresponding plan CT, dose was computed on these from adaptive replans (PLAN) and deformably accumulated back to the original planning CT. Cumulative D98% of CTV of PT (ITV for 82Gy) and LN, and normal tissue dose changes were analyzed. Results: Two patients were removed from the study due to large registration errors. For the remaining 7 patients, D98% for CTV-PT (ITV-PT for 82 Gy) and CTV-LN was within 1 Gy of PLAN for both 66 Gy and 82 Gy plans with both setup techniques. Overall, TC based setup provided better results, especially for LN coverage (p = 0.1 for 66Gy plan and p = 0.2 for 82 Gy plan, comparison of BN and TC), though not significant. Normal tissue dose constraints violated for some patients if constraint was barely achieved in PLAN. Conclusion: The hypofractionated adaptive strategy appears to be deliverable with soft tissue alignment for the evaluated margins and planning parameters. Research was supported by NIH P01CA116602.

60 APPLIED LIFE SCIENCES↗

WE-G-BRF-09: Force- and Image-Adaptive Strategies for Robotised Placement of 4D Ultrasound Probes

Purpose: To allow continuous acquisition of high quality 4D ultrasound images for non-invasive live tracking of tumours for IGRT, image- and force-adaptive strategies for robotised placement of 4D ultrasound probes are developed and evaluated. Methods: The developed robotised ultrasound system is based on a 6-axes industrial robot (adept Viper s850) carrying a 4D ultrasound transducer with a mounted force-torque sensor. The force-adaptive placement strategies include probe position control using artificial potential fields and contact pressure regulation by a PD controller strategy. The basis for live target tracking is a continuous minimum contact pressure to ensure good image quality and high patient comfort. This contact pressure can be significantly disturbed by respiratory movements and has to be compensated. All measurements were performed on human subjects under realistic conditions. When performing cardiac ultrasound, rib- and lung shadows are a common source of interference and can disrupt the tracking. To ensure continuous tracking, these artefacts had to be detected to automatically realign the probe. The detection is realised by multiple algorithms based on entropy calculations as well as a determination of the image quality. Results: Through active contact pressure regulation it was possible to reduce the variance of the contact pressure by 89.79% despite respiratory motion of the chest. The results regarding the image processing clearly demonstrate the feasibility to detect image artefacts like rib shadows in real-time. Conclusion: In all cases, it was possible to stabilise the image quality by active contact pressure control and automatically detected image artefacts. This fact enables the possibility to compensate for such interferences by realigning the probe and thus continuously optimising the ultrasound images. This is a huge step towards fully automated transducer positioning and opens the possibility for stable target tracking in ultrasoundguided radiation therapy requiring contact pressure of 5–10 N. This work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

SU-E-I-39: Combining Conventional Tomographic Imaging Strategy and Interior Tomography for Low Dose Dual-Energy CT (DECT)

Purpose: Dual-energy CT (DECT) affords quantitative information of tissue density and provides a new dimension for disease diagnosis and treatment planning. The technique, however, increases the imaging dose because of the doubled scans, and thus hinders its widespread clinical applications. The purpose of this work is to develop a novel hybrid DECT image acquisition and reconstruction strategy, in which one of the energies is dealt by interior tomography while the other one is obtained using conventional tomography approach. Methods: In the proposed hybrid imaging strategy, the projection data of one of the energies (e.g., high-energy) were acquired and processed in an interior scanning model, whereas the other energy in the conventional tomographic approach. It known that, if the ROI is piecewise constant or polynomial, the interior ROI can be reconstructed with TV or HOT minimization. Here we extend the TV based interior reconstruction method into dual-energy situation. The ROI images so obtained were overlaid in the context of conventional CT of the companion energy. A material based composition in ROI was used in the proposed reconstruction framework. Results: In the simulation experiment with a diagnostic DECT geometry and energies, we were able to derive the densities of soft-tissues and bones in the ROI with high fidelity. In the experimental CBCT study, both kV and MV data were collected using the on-board kV and MV imaging system. The MV data were truncated only across the ROI. Using the interior tomography reconstruction above, we were able to obtain the ROI images as that obtained using un-truncated MV data with known tissue densities. Conclusion: The proposed DECT imaging strategy provides an effective way to extract tissue density information in the ROI and in the context of anatomical images of CT imaging, with much reduced imaging dose.

60 APPLIED LIFE SCIENCES↗

WE-AB-201-04: The Recommendations of MPPG #5 and Practical Implementation Strategies

Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar defects in the future. Finally, the Gamma test has become a popular metric for reporting TPS Commissioning and QA results. It simplifies complex testing into a numerical index, but noisy data and casual application can make it misleading. A brief review of the issues around the use of the Gamma test will be presented. TPS commissioning and QA: A process orientation and application of control charts (Michael Sharpe) A framework for commissioning a treatment planning system will be presented, focusing on preparations, practical aspects of configuration, priorities, specifications, and establishing performance. The complexity of the modern TPS make modular testing of features inadequate, and modern QA tools can provide “too much information” about the performance of techniques like IMRT and VMAT. We have adopted a process orientation and quality tools, like control charts, for ongoing TPS QA and assessment of patient-specific tests. The trending nature of these tools reveals the overall performance of the TPS system, and quantifies the variations that arise from individual plans, discrete calculations, and experimentation based on discrete measurements. Examples demonstrating application of these tools to TPS QA will be presented. TPS commissioning and QA: Incorporating the entire planning process (Sasa Mutic) The TPS and its features do not perform in isolation. Instead, the features and modules are key components in a complex process that begins with CT Simulation and extends to treatment delivery, along with image guidance and verification. Most importantly, the TPS is used by people working in a multi-disciplinary environment. It is very difficult to predict the outcomes of human interactions with software. Therefore, an interdisciplinary approach to training, commissioning and QA will be presented, along with an approach to the physics chart check and end-to-end testing as a tool for TPS QA. The role of standardization and automation in QA will also be discussed. The recommendations of MPPG #5 and practical implementation strategies (Jennifer Smilowitz) The recently published recommendations from Task Group No. 244, Medical Physics Practice Guideline on Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams will be presented. The recommendations focus on the validation of commissioning data and dose calculations. Tolerance values for non-IMRT beam configurations are summarized based on established criteria and data collected by the IROC. More stringent evaluation criteria for IMRT dose calculations are suggested to test the limitations of the TPS dose algorithms for advanced delivery conditions. The MPPG encourages users to create a suite of validation tests for dose calculation for various conditions for static photon beams, heterogeneities, IMRT/VMAT and electron beams. This test suite is intended to be used for subsequent testing, including TPS software upgrades. In the past, the recommendations of some reports have not been widely implemented due to practical limitations. Implementation strategies, tools and processes developed by multiple centers for efficient and “do-able” MPPG #5 testing will be presented, as well as a discussion on the overall validation experience. Learning Objectives: Identify some of the key documents relevant for TPS commissioning and QA Understand strategies for testing TPS software Gain a practical knowledge of the Gamma test criteria Increase familiarity with the process of commissioning a TPS Learn about the use of Control Charts for TPS QA Review the role of the TPS in the overall planning process Increase awareness of the link between TPS QA and chart checking Gain an increased appreciation for the importance of interdisciplinary communication Understand the new recommendations from MPPG #5 on TPS Dose Algorithm Commissioning and QC/QA Learn practical implementation processes and tools for MPPG #5 validation recommendations.

60 APPLIED LIFE SCIENCES↗

Secure biosystems design in Saccharomyces cerevisiae establishes effective biocontainment strategies and mechanisms of escape

The widespread application of recombinant DNA and synthetic biology approaches for microbial metabolic engineering pursuits has motivated the development of biocontainment strategies, targeting safe and secure deployment of genetically modified microorganisms (GMMs). However, the design rules and mechanistic drivers governing biocontainment efficacy, as well as impacts of biocontainment upon microbial fitness, remain to be comprehensively evaluated, hindering predictive design and application of these strategies. We have developed a platform for high-resolution analysis of a transactivated kill switch in laboratory and industrial strains of Saccharomyces cerevisiae to assess modes of biocontainment escape and establish design rules for development of kill switch systems in diverse microbes. A camphor-regulated, RelE toxin system was systematically deployed to assess the impacts of differential kill switch copy number and ploidy in laboratory vs industrial strains. CRISPR-mediated integration of the biocontainment system at various loci revealed rapid escape events driven, in part, by mutations to both the Cam-transactivator (cam-TA) and RelE toxin. Genetic engineering enabled recapitulation of escape phenotypes, confirming mechanisms of escape and establishing structure-function relationships in the cam-TA system. Interestingly, genomic resequencing of escape mutants also revealed a series of off-target mutations, implicating additional modes of kill switch escape. Multi-copy integration of the kill switch system mitigated these effects by orders of magnitude, without compromising the biosynthetic capacity of the microbes, but proved insufficient to establish sustained biocontainment. The resultant data define a series of key design rules for next-generation biocontainment strategies and add to a growing foundational knowledge base targeting establishment of secure biosystems designs.

59 BASIC BIOLOGICAL SCIENCES↗

Distinct Growth and Secretome Strategies for Two Taxonomically Divergent Brown Rot Fungi

Brown rot fungi are wood-degrading fungi that employ both oxidative and hydrolytic mechanisms to degrade wood. Hydroxyl radicals that facilitate the oxidative component are powerful nonselective oxidants and are incompatible with hydrolytic enzymes unless they are spatially segregated in wood. Differential gene expression has been implicated in the segregation of these reactions in Postia placenta , but it is unclear if this two-step mechanism varies in other brown rot fungi with different traits and life history strategies that occupy different niches in nature. We employed proteomics to analyze a progression of wood decay on thin wafers, using brown rot fungi with significant taxonomic and niche distances: Serpula lacrymans (Boletales; “dry rot” lumber decay) and Gloeophyllum trabeum (order Gloeophyllales; slash, downed wood). Both fungi produced greater oxidoreductase diversity upon wood colonization and greater glycoside hydrolase activity later, consistent with a two-step mechanism. The two fungi invested very differently, however, in terms of growth (infrastructure) versus protein secretion (resource capture), with the ergosterol/extracted protein ratio being 7-fold higher with S. lacrymans than with G. trabeum . In line with the native substrate associations of these fungi, hemicellulase-specific activities were dominated by mannanase in S. lacrymans and by xylanase in G. trabeum . Consistent with previous observations, S. lacrymans did not produce glycoside hydrolase 6 (GH6) cellobiohydrolases (CBHs) in this study, despite taxonomically belonging to the order Boletales, which is distinguished among brown rot fungi by having CBH genes. This work suggests that distantly related brown rot fungi employ staggered mechanisms to degrade wood, but the underlying strategies vary among taxa.Wood-degrading fungi are important in forest nutrient cycling and offer promise in biotechnological applications. Brown rot fungi are unique among these fungi in that they use a nonenzymatic oxidative pretreatment before enzymatic carbohydrate hydrolysis, enabling selective removal of carbohydrates from lignin. This capacity has independently evolved multiple times, but it is unclear if different mechanisms underpin similar outcomes. Here, we grew fungi directionally on wood wafers and we found similar two-step mechanisms in taxonomically divergent brown rot fungi. The results, however, revealed strikingly different growth strategies, with S. lacrymans investing more in biomass production than secretion of proteins and G. trabeum showing the opposite pattern, with a high diversity of uncharacterized proteins. The “simplified” S. lacrymans secretomic system could help narrow gene targets central to oxidative brown rot pretreatments, and a comparison of its distinctions with G. trabeum and other brown rot fungi (e.g., Postia placenta ) might offer similar traction in noncatabolic genes.

59 BASIC BIOLOGICAL SCIENCES↗

Partitioning and Communication Strategies for Sparse Non-negative Matrix Factorization

Non-negative matrix factorization (NMF), the problem of finding two non-negative low-rank factors whose product approximates an input matrix, is a useful tool for many data mining and scientific applications such as topic modeling in text mining and unmixing in microscopy. In this paper, we focus on scaling algorithms for NMF to very large sparse datasets and massively parallel machines by employing effective algorithms, communication patterns, and partitioning schemes that leverage the sparsity of the input matrix. We consider two previous works developed for related problems, one that uses a fine-grained partitioning strategy using a point-to-point communication pattern and one that uses a Cartesian, or checkerboard, partitioning strategy using a collective-based communication pattern. We show that a combination of the previous approaches balances the demands of the various computations within NMF algorithms and achieves high efficiency and scalability. From the experiments, we see that our proposed strategy runs up to 10x faster than the state of the art on real-world datasets.

Kaya, Oguz↗

Mitigative Strategies for Recovering From Large Language Model Trust Violations

In this study, we investigated strategies to address trust issues arising from errors in large language models (LLMs). The study examined the impact of confidence scores, system capability explanations, and user feedback on trust restoration post-error. 68 participants viewed the responses of an LLM to 20 general trivia questions, with an error introduced on the third trial. Each participant was presented with one mitigation strategy. Participants rated their overall trust in the model and the reliability of the answer. Results showed an immediate drop in trust after the error; however, there were no differences across the three strategies in trust recovery. All conditions had a logarithmic trend in trust recovery following error. Differences in overall trust were predicted by perceived reliability of the answer, suggesting that participants were evaluating results critically and using that to inform their trust in the model. Qualitative data supported this finding; participants expressed lasting distrust despite the LLM’s later accuracy. Results showcase the need to prioritize accuracy in LLM deployment, because early errors may irrevocably damage user trust calibration and later adoption.

97 MATHEMATICS AND COMPUTING↗

Crystallographic texture engineering through novel melt strategies via electron beam melting: Inconel 718

Preliminary research has demonstrated the ability to utilise novel scan strategies in the electron beam melting (EBM) process to establish control of crystallographic texture within Inconel 718 deposits. Conventional EBM scan strategies and process parameters yield coarse columnar grains aligned parallel to the build direction. Through varying process parameters such as beam power, beam velocity, beam focus and scan strategy, the behaviour of the electron beam can be manipulated from a line source to a point source. The net effect of these variations is that the resulting crystallographic texture is controlled in a manner to produce either epitaxial deposits or fully equiaxed deposits. Furthermore, this research demonstrates the ability to change the crystallographic texture on the macroscale indicating that EBM technology can be used to create complex geometric components with both site-specific microstructures and material properties.

36 MATERIALS SCIENCE↗

Data for Evaluation of Strategies to Narrow the Product Chain-Length Distribution of Microbially Synthesized Free Fatty Acids

The dominant strategy for tailoring the chain-length distribution of free fatty acids (FFA) synthesized by heterologous hosts is expression of a selective acyl-acyl carrier protein (ACP) thioesterase. However, few of these enzymes can generate a precise (greater than 90% of a desired chain-length) product distribution when expressed in a microbial or plant host. The presence of alternative chain-lengths can complicate purification in situations where blends of fatty acids are not desired. We report the assessment of several strategies for improving the dodecanoyl-ACP thioesterase from the California bay laurel to exhibit more selective production of medium-chain free fatty acids to near exclusivity. We demonstrated that matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) was an effective library screening technique for identification of thioesterase variants with favorable shifts in chain-length specificity. This strategy proved to be a more effective screening technique than several rational approaches discussed herein. With this data, we isolated four thioesterase variants which exhibited a more selective FFA distribution over wildtype when expressed in the fatty acid accumulating E. coli strain, RL08. We then combined mutations from the MALDI isolates to generate BTE-MMD19, a thioesterase variant capable of producing free fatty acids consisting of 90% of C12 products. Of the four mutations which conferred a specificity shift, we noted that three affected the shape of the binding pocket, while one occurred on the positively charged acyl carrier protein landing pad. Finally, we fused the maltose binding protein (MBP) from E. coli to the N – terminus of BTE-MMD19 to improve enzyme solubility and achieve a titer of 1.9 g per L of twelve-carbon fatty acids in a shake flask.

Conversion↗

Westinghouse advanced fuel management strategies leveraging high enrichment and high burnup fuel to optimize PWR economics

In the US, nuclear power plants have been focused on increasing electricity generation for over three decades via longer operating cycles, reduced number of outages and duration, and the implementation of power up-rates. The potential for zero-carbon emission credits and other carbon-reduction initiatives further makes nuclear power utilities to focus on increasing generation capability. Longer operating cycles provide increased energy generation and enable economic savings to nuclear utilities when the increase in fuel loading required to achieve the extended cycle energy target and resulting increase in total fuel cost is offset by the savings from outage avoidance and reduced replacement power costs. For the current licensed limits of 5 w/o {sup 235}U enrichment and 62 GWd/tU peak pin burnup, higher power density PWR plants, which are prevalent in the PWR fleet, require an excessively penalizing fraction of feed fuel assemblies to operate for the extended cycle duration, with inevitably poor fuel use and fuel cycle economics that cannot be counterbalanced by the savings on outage cost avoidance. To overcome this barrier, the nuclear industry is pursuing development of high enrichment/high burnup fuel technology ({sup 235}U enrichment up to 8 w/o and peak pin burnup up to 75 GWd/tU) which increases fuel energy generation capability and can enable high power density plants to achieve positive economics on 24-month cycle of operation. This paper presents advanced fuel management strategies developed by Westinghouse to enable transition of PWR reactors from 18-month to 24-month cycle of operation, with and without a core thermal power uprate, which are then used as basis to assess the economics of a direct transition from 18 to 24-month cycles with high enrichment/high burnup fuel. The results show that these fuel management strategies, especially if coupled with thermal power up-rates, present the opportunity for substantial economic benefits to utilities. The systematic review of fuel management strategies presented can provide an illustrative reference for decision makers as they consider how to maximize nuclear energy generation economically. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Physics Briefing Book: Input for the 2026 update of the European Strategy for Particle Physics

The European Strategy for Particle Physics (ESPP) reflects the vision and presents concrete plans of the European particle physics community for advancing human knowledge in fundamental physics. The ESPP is updated every five-to-six years through a community-driven process. It commences with the submission of specific proposals and other input from the community at large, outlining projects envisioned for the near-, mid-, and long-term future. All submitted contributions are evaluated by the Physics Preparatory Group (PPG), and a preliminary analysis is presented at a Symposium meant to foster a broad community discussion on the scientific value and feasibility of the various ideas proposed. The outcomes of the analysis and the deliberations at the Symposium are synthesized in the current Briefing Book, which provides an important input in the deliberations of the Strategy recommendations by the European Strategy Group (ESG).

de Blas, Jorge [Univ. of Granada (Spain); et al.]↗

Development of the ANL Plant Dynamics Code and Control Strategies for the Supercritical Carbon Dioxide Brayton Cycle and Code Validation with Data from the Sandia Small-Scale Supercritical Carbon Dioxide Brayton Cycle Test Loop

Significant progress has been made in the ongoing development of the Argonne National Laboratory (ANL) Plant Dynamics Code (PDC), the ongoing investigation and development of control strategies, and the analysis of system transient behavior for supercritical carbon dioxide (S-CO 2 ) Brayton cycles. Several code modifications have been introduced during FY2011 to extend the range of applicability of the PDC and to improve its calculational stability and speed. A new and innovative approach was developed to couple the Plant Dynamics Code for S-CO 2 cycle calculations with SAS4A/SASSYS-1 Liquid Metal Reactor Code System calculations for the transient system level behavior on the reactor side of a Sodium-Cooled Fast Reactor (SFR) or Lead-Cooled Fast Reactor (LFR). The new code system allows use of the full capabilities of both codes such that whole-plant transients can now be simulated without additional user interaction. Several other code modifications, including the introduction of compressor surge control, a new approach for determining the solution time step for efficient computational speed, an updated treatment of S-CO 2 cycle flow mergers and splits, a modified enthalpy equation to improve the treatment of negative flow, and a revised solution of the reactor heat exchanger (RHX) equations coupling the S-CO 2 cycle to the reactor, were introduced to the PDC in FY2011. All of these modifications have improved the code computational stability and computational speed, while not significantly affecting the results of transient calculations. The improved PDC was used to continue the investigation of S-CO 2 cycle control and transient behavior. The coupled PDC-SAS4A/SASSYS-1 code capability was used to study the dynamic characteristics of a S-CO 2 cycle coupled to a SFR plant. Cycle control was investigated in terms of the ability of the cycle to respond to a linear reduction in the electrical grid demand from 100% to 0% at a rate of 5%/minute. It was determined that utilization of turbine throttling control below 50% load improves the cycle efficiency significantly. Consequently, the cycle control strategy has been updated to include turbine throttle valve control. The new control strategy still relies on inventory control in the 50%-90% load range and turbine bypass for fine and fast generator output adjustments, but it now also includes turbine throttling control in the 0%-50% load range. In an attempt to investigate the feasibility of using the S-CO 2 cycle for normal decay heat removal from the reactor, the cycle control study was extended beyond the investigation of normal load following. It was shown that such operation is possible with the extension of the inventory and the turbine throttling controls. However, the cycle operation in this range is calculated to be so inefficient that energy would need to be supplied from the electrical grid assuming that the generator could be capable of being operated in a motoring mode with an input electrical energy from the grid having a magnitude of about 20% of the nominal plant output electrical power level in order to maintain circulation of the CO 2 in the cycle. The work on investigation of cycle operation at low power level will be continued in the future. In addition to the cycle control study, the coupled PDC-SAS4A/SASSYS-1 code system was also used to simulate thermal transients in the sodium-to-CO 2 heat exchanger. Several possible conditions with the potential to introduce significant changes to the heat exchanger temperatures were identified and simulated. The conditions range from reactor scram and primary sodium pump failure or intermediate sodium pump failure on the reactor side to pipe breaks and valve malfunctions on the S-CO 2 side. It was found that the maximum possible rate of the heat exchanger wall temperature change for the particular heat exchanger design assumed is limited to ±7 C/s for less than 10 seconds. Modeling in the Plant Dynamics Code has been compared with available data from the Sandia National Laboratories (SNL) small-scale S-CO 2 Brayton cycle demonstration that is being assembled in a phased approach currently at Barber-Nichols Inc. and at SNL in the future. The available data was obtained with an earlier configuration of the S-CO 2 loop involving only a single-turbo-alternator-compressor (TAC) instead of two TACs, a single low temperature recuperator (LTR) instead of both a LTR and a high temperature recuperator (HTR), and fewer than the later to be installed full set of electric heaters. Due to the absence of the full heating capability as well as the lack of a high temperature recuperator providing additional recuperation, the temperature conditions obtained with the loop are too low for the loop conditions to be prototypical of the S-CO 2 cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY12 Annual Report: PHEV Engine Control and Energy Management Strategy

The objectives are: (1) Investigate novel engine control strategies targeted at rapid engine/catalyst warming for the purpose of mitigating tailpipe emissions from plug-in hybrid electric vehicles (PHEV) exposed to multiple engine cold start events; (2) Optimize integration of engine control strategies with hybrid supervisory control strategies in order to reduce cold start emissions and fuel consumption of PHEVs; and (3) Ensure that development of new vehicle technologies complies with existing emission standards.

33 ADVANCED PROPULSION SYSTEMS↗

Strategy Guideline: Transitioning HVAC Companies to Whole House Performance Contractors

This Strategy Guideline describes the findings from research that the U.S. Department of Energy’s Building America team IBACOS conducted related to heating, ventilation, and air conditioning (HVAC) companies that have made the decision to transition to whole house performance contracting (WHPC). By utilizing a house-as-a-system approach, the WHPC contractor can evaluate the total energy performance of the entire house and make upgrades on a prioritized basis, according to the energy benefit. IBACOS believes that an HVAC contractor is well suited to take on the tasks of whole house energy upgrades and to advance large-scale energy efficiency in the residential market. Because the HVAC contractor already works on one of the most technically complex systems in the house, they have already overcome the barrier of training to the complex HVAC system and can reduce the time required to transition to delivering whole house energy upgrades on a wide scale. Providing contractors with new technical skills and a revised business approach is one way to achieve change on a large scale and to help the United States meet its goals regarding job creation and energy independence. However, HVAC companies need guidance on how to transition successfully from their traditional business approach to one that includes WHPC. Research for this Strategy Guideline included a literature search of periodicals, industry trade publications, and reports available to the general public on the topic of WHPC. IBACOS created an outline of a successfully integrated HVAC company with a WHPC business and presented the outline to a group of experts currently working in the industry. The feedback received from the experts was used to identify the key areas in which guidance would be most useful to WHPC contractors, and eight of these areas were expanded for guidance. The appendices included with this Strategy Guideline present information a transitioning contractor may find useful and were collected from published periodicals, along with short and concise Fact Sheets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Foundation Insulation Strategies for the 2012 International Energy Conservation Code in Cold Climate New Home Construction

Even though the International Energy Conservation Code 2012 (International Code Council 2012) is a model code now available for adoption by individual states, only two cold-climate states have adopted it as their new home energy code. Understanding the resistance to adoption is important in assisting more states to accept the code and engage in deep energy strategies nationwide. This three-part assessment by the NorthernSTAR Building America Partnership was focused on foundation insulation R-values for cold climates and the design, construction, and performance implications. In Section 1, a literature review and attendance at stakeholder meetings held in Minnesota were used to assess general stakeholder interest and concerns about proposed code changes. Section 2 includes drawings of robust foundation insulation systems that were presented at one Minnesota stakeholder meeting to address critical issues and concerns for adopting best practice strategies. In Section 3, a sampling of builders participated in a telephone interview to gain baseline knowledge on insulation systems used to meet the current energy code and how the same builders intend to meet the new proposed code. In general, most builders expressed interest in being able to deliver greater energy efficiency to their customers. Concerns were voiced, however, about the costs compared to the energy savings, constructability, and durability risk resulting from increased foundation insulation R-values. When solutions for building robust foundation wall systems were presented to stakeholders, they did express interest in learning the details of the strategies. There was, however, continued interest in proof of cost, payback, and hygrothermal performance. Builders who participated in the interview were more confident in being able to meet the new requirements. This might have been a result of these respondents already using more advanced techniques for foundation insulation. This insight gives Building America an opportunity to engage the industry with existing research and practice measures that can address constructability and durability concerns at the proposed code levels. It also indicates that builders are interested in more specific information on cost, energy savings, and overall hygrothermal performance. Filling these voids could yield the supportive data needed to enhance building industry confidence and engage more states in the adoption of 2012 International Energy Conservation Code for new homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗