Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

BEYONDPLANCK IV. On end-to-end simulations in CMB analysis — Bayesian versus frequentist statistics

End-to-end simulations play a key role in the analysis of any high-sensitivity cosmic microwave background (CMB) experiment, providing high-fidelity systematic error propagation capabilities that are unmatched by any other means. In this paper, we address an important issue regarding such simulations, namely, how to define the inputs in terms of sky model and instrument parameters. These may either be taken as a constrained realization derived from the data or as a random realization independent from the data. We refer to these as posterior and prior simulations, respectively. We show that the two options lead to significantly different correlation structures, as prior simulations (contrary to posterior simulations) effectively include cosmic variance, but they exclude realization-specific correlations from non-linear degeneracies. Consequently, they quantify fundamentally different types of uncertainties. We argue that as a result, they also have different and complementary scientific uses, even if this dichotomy is not absolute. In particular, posterior simulations are in general more convenient for parameter estimation studies, while prior simulations are generally more convenient for model testing. Before BEYONDPLANCK, most pipelines used a mix of constrained and random inputs and applied the same hybrid simulations for all applications, even though the statistical justification for this is not always evident. BEYONDPLANCK represents the first end-to-end CMB simulation framework that is able to generate both types of simulations and these new capabilities have brought this topic to the forefront. The BEYONDPLANCK posterior simulations and their uses are described extensively in a suite of companion papers. In this work, we consider one important applications of the corresponding prior simulations, namely, code validation. Specifically, we generated a set of one-year LFI 30 GHz prior simulations with known inputs and we used these to validate the core low-level BEYONDPLANCK algorithms dealing with gain estimation, correlated noise estimation, and mapmaking.

79 ASTRONOMY AND ASTROPHYSICS↗

Early Results from the Q{sub weak} Experiment

A subset of results from the recently completed Jefferson Lab Q{sub weak} experiment are reported. This experiment, sensitive to physics beyond the Standard Model, exploits the small parity-violating asymmetry in elastic {vector e}p scattering to provide the first determination of the protons weak charge Q{sub w}{sup p}. The experiment employed a 180 {micro}A longitudinally polarized 1.16 GeV electron beam on a 35 cm long liquid hydrogen target. Scattered electrons corresponding to Q{sup 2} of 0.025 GeV{sup 2} were detected in eight Cerenkov detectors arrayed symmetrically around the beam axis. The goals of the experiment were to provide a measure of Q{sub w}{sup p} to 4.2 percent (combined statistical and systematic error), which implies a measure of sin2(thetaw) at the level of 0.3 percent, and to help constrain the vector weak quark charges C{sub 1u} and C{sub 1d}. The experimental method is described, with particular focus on the challenges associated with the worlds highest power LH{sub 2} target. The new constraints on C{sub 1u} and C{sub 1d} provided by the subset of the experiments data analyzed to date will also be shown, together with the extracted weak charge of the neutron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis and calibration of absorptive images of Bose-Einstein condensate at nonzero temperatures

We describe the method allowing quantitative interpretation of absorptive images of mixtures of Bose-Einstein condensate and thermal atoms which reduces possible systematic errors associated with evaluation of the contribution of each fraction and eliminates arbitrariness of most of the previous approaches. By using known temperature dependence of the BEC fraction, the analysis allows precise calibration of the fitting results. The developed method is verified in two different measurements and compares well with theoretical calculations and with measurements performed by another group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deconvolution-based correction of alkali beam emission spectroscopy density profile measurements

A deconvolution-based correction method of the beam emission spectroscopy (BES) density profile measurement is demonstrated by its application to simulated measurements of the COMPASS and TEXTOR tokamaks. If the line of sight is far from tangential to the flux surfaces, and the beam width is comparable to the scale length on which the light profile varies, the observation may cause an undesired smoothing of the light profile, resulting in a non-negligible underestimation of the calculated density profile. This effect can be reduced significantly by the emission reconstruction method, which gives an estimate of the emissivity along the beam axis from the measured light profile, taking the finite beam width and the properties of the measurement into account in terms of the transfer function of the observation. Characteristics and magnitude of the mentioned systematic error and its reduction by the introduced method are studied by means of the comprehensive alkali BES simulation code RENATE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Q{sub weak}{sup p} Experiment A Test for Physics Beyond the Standard Model via a Precision Measurement of the Proton Weak Charge

The Qweak collaboration is currently preparing a measurement of the proton's weak charge Q{sub w}{sup p} = (1-4 sin{sup 2} {theta}{sub w}) at the Thomas Jefferson National Accelerator Facility (TJNAF). The experiment has been designed to produce a 4.1% measurement of the weak charge, via a 2.5% measurement of the parity violating asymmetry in the number of elastically scattered 1 GeV electrons from protons, at forward angles. At the proposed precision, the experiment would produce a 0.3% measurement of the weak mixing angle at a momentum transfer of {approx_equal}0.16 GeV, making it the most precise stand alone measurement of the weak mixing angle at low momentum transfer. In combination with other parity measurements, Qweak will also provide a high precision determination of the weak charges of the up and down quarks. Our proposed measurement of Q{sub w}{sup 2} will be performed with significantly smaller statistical and systematic errors than existing low Q{sup 2} data. Any significant deviation from the Standard Model prediction at low momentum transfer (Q{sup 2}) would be a signal of new physics, whereas agreement would place new and significant constraints on possible Standard Model extensions. The experiment is currently being prepared for installation, beginning in late 2009, and data taking beginning in mid 2010.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards High Precision Deuteron Polarimetry

A finite electric dipole moment (EDM) in any fundamental system would constitute a signal for new physics. The deuteron presents itself as an optimal candidate both experimentally and theoretically. A new storage ring technique is being developed for which a small change in the vertical polarization would be a signal of a non-zero EDM. A novel polarimeter concept is under investigation. Besides being highly efficient, this polarimeter should continuously monitor the beam polarization, guaranteeing optimal sensitivity. Detailed studies on systematic error control, in addition to the measurement of cross sections and analyzing powers, were carried out at KVI-Groningen in The Netherlands. Measurements were conducted at COSY-Juelich in Germany yielding high efficiencies. The (statistics limited) ability to track changes in polarization at the level of a few hundred parts-per-million has been demonstrated. Further studies and developments to meet the final goal of sub-part-per-million sensitivity are in progress.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a pepper-pot device to determine the emittance of an ion beam generated by electron cyclotron resonance ion sources

This paper describes the recent development and commissioning of a pepper-pot emittance meter at the Lawrence Berkeley National Laboratory (LBNL). It is based on a potassium bromide (KBr) scintillator screen in combination with a charged coupled device camera. Pepper-pot scanners record the full four-dimensional transverse phase space emittances which are particularly interesting for electron cyclotron resonance ion sources. The strengths and limitations of evaluating emittances using optical pepper-pot scanners are described and systematic errors induced by the optical data acquisition system will be presented. Light yield tests of KBr exposed to different ion species and first emittance measurement data using ion beams extracted from the 6.4 GHz LBNL electron cyclotron resonance ion source are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of quasi-elastic muon (anti)neutrino scattering in he NOMAD experiment

We have studied the muon neutrino and antineutrino quasi-elastic (QEL) scattering reactions (v{sub {mu}}n{yields}{mu}{sup -}p and v-bar{sub {mu}}p{yields}{mu}{sup +}n using a set of experimental data collected by the NOMAD collaboration. We have performed measurements of the cross-section of these processes on a nuclear target (mainly Carbon) normalizing it to the total v{sub {mu}} (v-bar{sub {mu}}) charged current cross-section. The results for the flux averaged QEL cross-sections in the (anti)neutrino energy interval 3-100 GeV are <{sigma}{sub qel}>v{sub {mu}} = (0.92{+-}0.02(stat){+-}0.06(syst))x10{sup -38} cm{sup 2} and <{sigma}{sub qel}>v-bar{sub {mu}} = (0.81{+-}0.05(stat){+-}0.09(syst))x10{sup -38} cm{sup 2} for neutrino and antineutrino, respectively. The axial mass parameter MA was extracted from the measured quasi-elastic neutrino cross-section. The corresponding result is M{sub A} = 1.05{+-}0.02(stat){+-}0.06(syst) GeV. It is consistent with the axial mass values recalculated from the antineutrino cross-section and extracted from the pure Q{sup 2} shape analysis of the high purity sample of v{sub {mu}} quasi-elastic 2-track events, but has smaller systematic error and should be quoted as the main result of this work. Our measured MA is found to be in good agreement with the world average value obtained in previous deuterium filled bubble chamber experiments. The NOMAD measurement of M{sub A} is lower than those recently published by K2K and MiniBooNE collaborations. However, within the large errors quoted by these experiments on M{sub A}, these results are compatible with the more precise NOMAD value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A precise new KLOE measurement of |F{sub {pi}}|{sup 2} with ISR events and determination of {pi}{pi} contribution to a{sub {mu}} for 0.592<M{sub {pi}}{sub {pi}}<0.975 GeV

The KLOE experiment at the DA{phi}NE {phi}-factory has performed a new precise measurement of the pion form factor using Initial State Radiation events, with photons emitted at small polar angle. Results based on an integrated luminosity of 240 pb{sup -1} and extraction of the {pi}{pi} contribution to a{sub {mu}} in the mass range 0.35<M{sub {pi}}{sub {pi}}{sup 2}<0.95 GeV{sup 2} are presented. The new value of a{sub {mu}}{sup {pi}}{sup {pi}} has smaller (30%) statistical and systematic error and is consistent with the KLOE published value (confirming the current disagreement between the standard model prediction for a{sub {mu}} and the measured value)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FREE SURFACE VELOCIMETRY CORRECTIONS FOR LOW PRESSURE SHOCKS

We consider how to interpret measured free surface velocities to estimate what a relatively weak shock (with an elastic-plastic two-wave structure, approx5-30 GPa) would have looked like in an infinite sample. Hysteresis and nonlinear wave interactions introduce effects (inexact velocity doubling and the delay, partial reflection, and reverberation of waves) whose magnitudes can be estimated with simple models. We argue, and demonstrate in a simulated test case, that these estimates can eliminate most of the systematic error introduced by the free surface during loading.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of Proton Structure and Parton Density Functions from HERA

A preliminary result is reported of the charged current and neutral current inclusive cross sections from e{sup +}p and e{sup -}p scattering obtained from a combination of published measurements from H1 and ZEUS. Taking into account the systematic error correlations in a coherent approach, a reduction of experimental uncertainties for combined results is achieved compared to the separate results of the H1 and ZEUS experiments. The combined results are used as input for a next-to-leading order (NLO) QCD parton distribution determination.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-precision measurements of the equation of state of hydrocarbons at 1-10 Mbar using laser-driven shock waves

The equation of state (EOS) of polystyrene and polypropylene were measured using laser-driven shock waves with pressures from 1 to 10 Mbar. Precision data resulting from the use of alpha-quartz as an impedance-matching (IM) standard tightly constrains the EOS of these hydrocarbons, even with the inclusion of systematic errors inherent to IM. The temperature at these high pressures was measured, which, combined with kinematic measurements, provide a complete shock EOS. Both hydrocarbons were observed to reach similar compressions and temperatures as a function of pressure. The materials were observed to transition from transparent insulators to reflecting conductors at pressures of 1 to 2 Mbar.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hadro-Production Measurements to Characterize the T2K Neutrino Flux with the NA61 Experiment at the CERN SPS

As the intensity of neutrino beams produced at accelerators increases, the systematic errors due to the poor characterization of the neutrino flux become a limiting factor for high precision neutrino oscillation experiments like T2K. This limitation comes mainly from the poor knowledge of production cross sections for pions and kaons at the same energy and over the same phase-space yielding these neutrino beams. Therefore new hadro-production measurements are mandatory. The NA61/SHINE is a large acceptance hadron spectrometer at the CERN-SPS designed for the study of the hadronic final states produced in interactions of various beam particles (protons, pi's, and heavy ions) with a variety of fixed targets at the SPS energies. Ongoing measurements with the NA61 detector for characterizing the neutrino beam of the T2K experiment at J-PARC are introduced. These measurements are performed using a 30 GeV proton beam impinging on carbon targets of different lengths, including a replica of the T2K target. The performance of the NA61 detector and preliminary NA61 measurements from the 2007 run are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DoubleChooz: Experiment Status

The Double Chooz experiment will use electron antineutrinos produced by the Chooz nuclear power station to search for a non-vanishing value of the theta{sub 13} neutrino mixing angle. Double Chooz will be the first in a series of new generation reactor neutrino experiments using identical detectors at different distances from the neutrino source to reduce the systematic error due to uncertainties of the neutrino flux and the detector acceptance. The far detector is expected to be operative by the beginning of 2010. Installation of the near detector will follow and is expected to be completed by the beginning of 2011.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Performance of LHCf Detector

In cosmic ray physics, the uncertainty of the hadron interaction model causes systematic errors of air shower simulations in high-energy region. To solve the problem, the LHCf experiment measures energies and transverse momenta of neutral particles emitted in the forward region of 14 TeV p-p collision at CERN LHC. Two LHCf detectors, consisting of sampling and imaging calorimeters, are installed at zero degree collision angle at + 140 m from the interaction point 1 (IP1). The energy resolution is confirmed as to be <5% and the position resolution <0.2 mm for gamma-rays with energies from 100 GeV to 200 GeV by test beam results at the CERN SPS. Use of the Front Counter reduces the beam-gas background by a factor 50.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-point motional Stark effect diagnostic for Madison Symmetric Torus

A high-precision spectral motional Stark effect (MSE) diagnostic provides internal magnetic field measurements for Madison Symmetric Torus (MST) plasmas. Currently, MST uses two spatial views - on the magnetic axis and on the midminor (off-axis) radius, the latter added recently. A new analysis scheme has been developed to infer both the pitch angle and the magnitude of the magnetic field from MSE spectra. Systematic errors are reduced by using atomic data from atomic data and analysis structure in the fit. Reconstructed current density and safety factor profiles are more strongly and globally constrained with the addition of the off-axis radius measurement than with the on-axis one only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correcting hot-wire measurements of stream-wise turbulence intensity in boundary layers

The current experimental activity aimed at resolving the scaling of stream-wise turbulence intensity profiles uu{sup +}(y{sup +}) with Reynolds number in turbulent flat plate boundary layers has brought the largely unresolved issue of correcting systematic errors in hot-wire measurements of uu{sup +}(y{sup +}) into focus. Here, a heuristic scheme is proposed to generate unique uu{sup +}(y{sup +};Re{sub {delta}{sup *}}) profiles from data obtained with single hot wires of widely different length, aspect ratio and construction over a large Reynolds number range of 4000 < or approx. Re{sub {delta}{sup *}} < or approx. 50 000. A comparison with LDA data and other checks suggest that the present correction scheme produces uu{sup +}(y{sup +};Re{sub {delta}{sup *}}) profiles close to the (unknown) true profiles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗