Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Master Oscillator and Phase Reference Line Design for the PIP-II Linac

The phase averaging reference line system provides the RF phase reference, LO and clock signals to the LLRF and other accelerator sub-systems. The PIP-II linac has RF systems at three frequencies - 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase-noise oscillator is used as the master oscillator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each frequency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, A. [Fermilab]↗

Fermilab PIP-II Master Oscillator and Precision Reference Line Design and Construction

The phase averaging reference line system pro- vides the RF phase reference, LO and clock sig- nals to the LLRF and other accelerator sub- systems. The PIP-II linac has RF systems at three frequencies – 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase- noise oscillator is used as the master oscil- lator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each fre- quency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, Ahmed [Fermilab]↗

Thermal Studies of CMS High-Granularity Calorimeter (HGCAL) Cassettes for the HL-LHC Upgrade

The CMS High Granularity Calorimeter (HGCAL) is a key endcap upgrade for the High-Luminosity LHC, designed to operate in an environment of extreme radiation and high particle rates. Each HGCAL cassette integrates silicon and scintillator modules, front-end ASICs, and a copper cooling plate that provides both mechanical integrity and thermal coupling using two-phase CO₂ cooling. Stable and uniform temperature control is essential to ensure reliable performance of the front-end electronics and to limit radiation-induced leakage currents in the silicon sensors. We present results from thermal characterization studies of pre-series HGCAL cassettes assembled and tested at Fermilab. Embedded RTD/PT1000 temperature sensors were used to measure gradients across copper cooling plates, module layers, and cassette edges under powering conditions representative of operation. The measured thermal behavior demonstrates effective heat transport through the cassette stack and highlights small but systematic variations correlated with geometry and assembly tolerances. These results validate the cooling performance of HGCAL cassettes.

Wang, Jinglu [Northwestern U.]↗

Circulation system for flowing uranium hexafluoride cavity reactor experiments

Research related to determining the feasibility of producing continuous power from fissile fuel in the gaseous state is presented. The development of three laboratory-scale flow systems for handling gaseous UF6 at temperatures up to 500 K, pressure up to approximately 40 atm, and continuous flow rates up to approximately 50g/s is presented. A UF6 handling system fabricated for static critical tests currently being conducted is described. The system was designed to supply UF6 to a double-walled aluminum core canister assembly at temperatures between 300 K and 400 K and pressure up to 4 atm. A second UF6 handling system designed to provide a circulating flow of up to 50g/s of gaseous UF6 in a closed-loop through a double-walled aluminum core canister with controlled temperature and pressure is described. Data from flow tests using UF6 and UF6/He mixtures with this system at flow rates up to approximately 12g/s and pressure up to 4 atm are presented. A third UF6 handling system fabricated to provide a continuous flow of UF6 at flow rates up to 5g/s and at pressures up to 40 atm for use in rf-heated, uranium plasma confinement experiments is described.

Jaminet, J. F.↗

Large area sheet task: Advanced Dendritic Web Growth Development

A melt level control system was implemented to provide stepless silicon feed rates from zero to rates exactly matching the silicon consumed during web growth. Bench tests of the unit were successfully completed and the system mounted in a web furnace for operational verification. Tests of long term temperature drift correction techniques were made; web width monitoring seems most appropriate for feedback purposes. A system to program the initiation of the web growth cycle was successfully tested. A low cost temperature controller was tested which functions as well as units four times as expensive.

Duncan, C. S.↗

Effect of Random Thermal Spikes on Stirling Convertor Heater Head Reliability

Onboard radioisotope power systems being developed to support future NASA exploration missions require reliable design lifetimes of up to 14 yr and beyond. The structurally critical heater head of the high-efficiency developmental Stirling power convertor has undergone extensive computational analysis of operating temperatures (up to 650 C), stresses, and creep resistance of the thin-walled Inconel 718 bill of material. Additionally, assessment of the effect of uncertainties in the creep behavior of the thin-walled heater head, the variation in the manufactured thickness, variation in control temperature, and variation in pressure on the durability and reliability were performed. However, it is possible for the heater head to experience rare incidences of random temperature spikes (excursions) of short duration. These incidences could occur randomly with random magnitude and duration during the desired mission life. These rare incidences could affect the creep strain rate and therefore the life. The paper accounts for these uncertainties and includes the effect of such rare incidences, random in nature, on the reliability. The sensitivities of variables affecting the reliability are quantified and guidelines developed to improve the reliability are outlined. Furthermore, the quantified reliability is being verified with test data from the accelerated benchmark tests being conducted at the NASA Glenn Research Center.

Shah, Ashwin R.↗

Effect of Random Thermal Spikes on Stirling Convertor Heater Head Reliability

Onboard radioisotope power systems being developed to support future NASA exploration missions require reliable design lifetimes of up to 14 yr and beyond. The structurally critical heater head of the high-efficiency developmental Stirling power converter has undergone extensive computational analysis of operating temperatures (up to 650 C), stresses, and creep resistance of the thin-walled Inconel 718 bill of material. Additionally assessment of the effect of uncertainties in the creep behavior of the thin-walled heater head, the variation in the manufactured thickness, variation in control temperature, and variation in pressure on the durability and reliability were performed. However, it is possible for the heater head to experience rare incidences of random temperature spikes (excursions) of short duration. These incidences could occur randomly with random magnitude and duration during the desired mission life. These rare incidences could affect the creep strain rate and therefore the life. The paper accounts for these uncertainties and includes the effect of such rare incidences, random in nature, on the reliability. The sensitivities of variables affecting the reliability are quantified and guidelines developed to improve the reliability are outlined. Furthermore, the quantified reliability is being verified with test data from the accelerated benchmark tests being conducted at the NASA Glenn Research Center.

Shah, Ashwin R.↗

Remote Sensing of Salinity: The Dielectric Constant of Sea Water

Global monitoring of sea surface salinity from space requires an accurate model for the dielectric constant of sea water as a function of salinity and temperature to characterize the emissivity of the surface. Measurements are being made at 1.413 GHz, the center frequency of the Aquarius radiometers, using a resonant cavity and the perturbation method. The cavity is operated in a transmission mode and immersed in a liquid bath to control temperature. Multiple measurements are made at each temperature and salinity. Error budgets indicate a relative accuracy for both real and imaginary parts of the dielectric constant of about 1%.

LeVine, David M.↗

Ex-situ Heat Treatment of TEM Foils in a Custom Titanium Fixture: A Case Study on Ni-based Superalloy

The advancement of microstructural characterization at the nanoscale is critical to understanding the microstructural evolution and performance of engineering materials. Transmission electron microscopy (TEM) plays a vital role in such investigations, particularly when coupled with controlled ex- and in-situ experiments. In this study, we introduce a novel method for ex-situ heat treatment (HT) of TEM foils using a custom-designed fixture, made from pure titanium, and vacuum furnace to inhibit oxidation. This approach ensures precise temperature control and minimal sample contamination during HT, critical for substructural characterization and analysis of metallic materials. The fixture consists of a titanium base with three slits, for three sample foils, and a titanium cap for closure. The entire assembly is placed in a vacuum heat treatment furnace with high vacuum capability to prevent oxidation. To validate the effectiveness of the setup, precipitation behavior and microstructural changes were studied in an IN725 variant heat-treated at 500°C for 1 hour and 282 variant heat-treated at 700°C for 1 hour, as case studies.

electron microscopy↗

Optical Plasma Control During ARC Carbon Nanotube Growth

To improve nanotube production, we developed a novel optical control technique, based on the shape of the visible plasma zone created between the anode and the cathode in the direct current (DC) arc process. For a given inert gas, we adjust the anode to cathode distance (ACD) in order to obtain strong visible vortices around the cathode. This enhance anode vaporization, which improve nanotubes formation. In light of our experimental results, we focus our discussion on the relationship between plasma parameters and nanotube growth. Plasma temperature control during arc process is achieved using argon, helium, and their mixtures as a buffer gases. The variation of the gas mixture from pure argon to pure helium changes plasma temperature. As a consequence, the microscopic characteristics of nanotubes as diameter distribution is changed moving from smaller values for argon to higher diameters for helium. We also observe a dependence of the macroscopic characteristics of the final products as Brunauer-Emmett-Teller (BET) surface area.

Hinkov, I.↗

Detailed Velocity, Temperature, and Heat Flux Measurements on a Large Scale Film Cooling Model

To investigate the flow physics of turbine film cooling, detailed mean and fluctuating velocity and temperature surveys were made in the turbulent jet flow field behind a row of large scale film cooling holes. Additionally, surface heat transfer, film effectiveness, and turbulent heat flux values were determined. Measurements were made in the NASA Engine Research Building (ERB) SW-6 test facility, which consists of an 8.15-in2 open-inlet wind tunnel with a temperature-controlled secondary flow system. The film-cooling test plate fit into the wind tunnel such that the heat transfer surface formed the wind tunnel floor. This plate consisted of a three-hole array of film cooling holes that were fed from a plenum of different temperature.

Fluid Mechanics↗

Composite strengthening

The mechanical behavior of unidirectionally reinforced metals is examined, with particular attention to fabrication techniques for artificial composites and eutectic alloys and to principles of fiber reinforcement. The properties of artificial composites are discussed in terms of strength of fiber composites, strength of ribbon-reinforced composites, crack initiation, crack propagation, and creep behavior. The properties of eutectic composites are examined relative to tensile strength, compressive strength, fracture, high-temperature strength, and fatigue. In the case of artificial composites, parallelism of fibers, good bonding between fibers and matrix, and freedom of fibers from damage are all necessary to ensure superior performance. For many eutectic systems there are stringent boundary conditions relative to melt purity and superheat, atmosphere control, temperature gradient, and growth rate in order to provide near-perfect alignment of the reinforcements with a minimum of growth defects.

Stoloff, N. S.↗

Apparatus Makes Precisely Saturated Solutions

Simple laboratory apparatus establishes equilibrium conditions of temperature and concentration in solutions for use in precise measurements of saturation conditions. With equipment typical measurement of saturation concentration of protein in solution established and measured within about 24 hours. Precisely saturated solution made by passing solvent or solution slowly along column packed with solute at precisely controlled temperature. If necessary, flow stopped for experimentally determined interval to allow equilibrium to be established in column.

Pusey, Marc L.↗

Rate constants for the reactions of OH with HFC-134a (CF3CH2F) and HFC-134 (CHF2CHF2)

Measurements of rate constants for HFC-134 (CF2HCF2H) relative to CH3CCl3, HFC-125, and HFC-134a are reported. The measurements were made in a slow-flow, temperature controlled photochemical reactor, and were based on relative rates of disappearance of the parent compounds as measured by FTIR spectroscopy. Hydroxyl radicals were generated by 254-nm photolysis of O3 in the presence of water vapor. NASA/JPL rate constants for the reference compounds are used to derive temperature-dependent rate constants of both compounds. Rate constants obtained from the different reference compounds are in excellent agreement. The presently recommended rate constant for HFC-134a is about 25 percent too high.

Demore, W. B.↗

Thermal Performance of Capillary Pumped Loops Onboard Terra Spacecraft

The Terra spacecraft is the flagship of NASA's Earth Science Enterprise. It provides global data on the state of atmosphere, land and oceans, as well as their interactions with solar radiation and one another. Three Terra instruments utilize Capillary Pumped Heat Transport System (CPHTS) for temperature control: Each CPHTS, consisting of two capillary pumped loops (CPLs) and several heat pipes and electrical heaters, is designed for instrument heat loads ranging from 25W to 264W. The working fluid is ammonia. Since the launch of the Terra spacecraft, each CPHTS has been providing a stable interface temperature specified by the instrument under all modes of spacecraft and instrument operations. The ability to change the CPHTS operating temperature upon demand while in service has also extended the useful life of one instrument. This paper describes the design and on-orbit performance of the CPHTS thermal systems.

Ku, Jentung↗

Explainable discrepancy checker and diagnosis for digital Twin-based supervisory control system

By virtually representing a physical object and process, a digital twin (DT) enables optimal autonomous operations by combining classical and novel frameworks in sensors, state predictions, and multi-input/multi-output systems. A DT’s values depend on how well models estimate quantities of interest and on how uncertainty is handled. Moreover, DTs often combine physics-based and data-driven models with mixed fidelities, where classical uncertainty quantification (UQ) struggles with many sources of uncertainty and real-time constraints. Here, this work presents a UQ-based discrepancy checking and diagnosis tool for a DT-based supervisory control system. The tool is developed using metadata from an automated DT development process to learn correlations between sources of uncertainties and outcomes. During operation, it compares predictions with measurements, attributes discrepancies to dominant sources, and recommends parameter and configuration updates. We verify the workflow on a synthetic temperature-control problem and deploy it on a virtual Thermal Energy Delivery System, reducing mismatch and improving control robustness.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Monoball energy transfer: Test report

An aluminum platform serves as a storage shelf for experiments transported on the space shuttle. This platform is attached to the shuttle storage area through several supports, each consisting of an attachment fitting, a monoball bearing, a clevis pin and a support strut. The experiments must be temperature controlled during and after launch. Consequently, heat loss through the plate, attachment fitting, monoball bearing, and strut are important. The overall conductance of the monoball bearing was determined by an experimental method of heating the outer ring with a nichrome resistance wire and cooling the inner ball with propylene glycol. Temperature differences across the bearing were measured for various heat fluxes. The overall conductance is 0.42 Watts/C (0.80 BTU/hr F), This yields a 16 watt loss for a 38 C temperature difference across the bearing.

Wessling, F. C.↗

Cold Stowage Flight Systems

The International Space Station (ISS) provides a test bed for researchers to perform science experiments in a variety of fields, including human research, life sciences, and space medicine. Many of the experiments being conducted today require science samples to be stored and transported in a temperature controlled environment. NASA provides several systems which aid researchers in preserving their science. On orbit systems provided by NASA include the Minus Eighty Laboratory freezer for ISS (MELFI), Microgravity Experiment Research Locker Incubator (MERLIN), and Glacier. These freezers use different technologies to provide rapid cooling and cold stowage at different temperature levels on board ISS. Systems available to researchers during transportation to and from ISS are MERLIN, Glacier, and Coldbag. Coldbag is a passive cold stowage system that uses phase change materials to maintain temperature. Details of these current technologies are provided along with operational experience gained to date. This paper discusses the capability of the current cold stowage hardware and how it may continue to support NASA s mission on ISS and in future exploration missions.

Campana, Sharon E.↗