Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test Article”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Calibration of the Verification Engineering Test Article-I (VETA-I) for AXAF using the VETA-I X-ray Detection System

Advanced X-ray Astrophysics Facility (AXAF) X-ray optics testing is conducted by VETA-I, which consists of six nested Wolter type I grazing-incidence mirrors; VETA's X-ray Detection System (VXDS) in turn measures the imaging properties of VETA-I, yielding FWHM and encircled energy of the X-ray image obtained, as well as its effective area. VXDS contains a high resolution microchannel plate imaging X-ray detector and a pinhole scanning system in front of proportional-counter detectors. VETA-I's X-ray optics departs from the AXAF flight configuration in that it uses a temporary holding fixture; its mirror elements are not cut to final length, and are not coated with the metal film used to maximize high-energy reflection.

Kellogg, E.↗

The X-37 Hot Structure Control Surface Testing

Thermal-structural testing of three hot structure control surface subcomponent test articles (STA) designed for the X-37 (Boeing Phantom Works, Huntington Beach, California) Orbital Vehicle (OV) has been completed. The test articles were subcomponents of the X-37 OV bodyflap and flaperon control surfaces.

Hudson, Larry D.↗

Freezable Radiator Coupon Testing and Full Scale Radiator Design

Freezable radiators offer an attractive solution to the issue of thermal control system scalability. As thermal environments change, a freezable radiator will effectively scale the total heat rejection it is capable of as a function of the thermal environment and flow rate through the radiator. Scalable thermal control systems are a critical technology for spacecraft that will endure missions with widely varying thermal requirements. These changing requirements are a result of the space craft s surroundings and because of different thermal loads during different mission phases. However, freezing and thawing (recovering) a radiator is a process that has historically proven very difficult to predict through modeling, resulting in highly inaccurate predictions of recovery time. This paper summarizes tests on three test articles that were performed to further empirically quantify the behavior of a simple freezable radiator, and the culmination of those tests into a full scale design. Each test article explored the bounds of freezing and recovery behavior, as well as providing thermo-physical data of the working fluid, a 50-50 mixture of DowFrost HD and water. These results were then used as a tool for developing correlated thermal model in Thermal Desktop which could be used for modeling the behavior of a full scale thermal control system for a lunar mission. The final design of a thermal control system for a lunar mission is also documented in this paper.

Lillibridge, Sean T.↗

TPSAS-NF1676L-12829-DND

Collaborative research between NASA and U.S. rotorcraft companies through the Vertical Lift Consortium, to design, test, and analyze representative validation test articles. - Representative problems and designs developed with partners - Validation articles and characterization specimens manufactured by partners - Develop analytical models to predict delamination behavior using commercial codes, characterization data, and test article data - NASA Space Act Agreement (SAA1-818) with CRI, August 2007 August 2012; funded through Subsonic Rotary Wing program

Gretchen B Murri↗

Design and Execution of the Hypersonic Inflatable Aerodynamic Decelerator Large-Article Wind Tunnel Experiment

The testing of 3- and 6-meter diameter Hypersonic Inflatable Aerodynamic Decelerator (HIAD) test articles was completed in the National Full-Scale Aerodynamics Complex 40 ft x 80 ft Wind Tunnel test section. Both models were stacked tori, constructed as 60 degree half-angle sphere cones. The 3-meter HIAD was tested in two configurations. The first 3-meter configuration utilized an instrumented flexible aerodynamic skin covering the inflatable aeroshell surface, while the second configuration employed a flight-like flexible thermal protection system. The 6-meter HIAD was tested in two structural configurations (with and without an aft-mounted stiffening torus near the shoulder), both utilizing an instrumented aerodynamic skin.

Cassell, Alan M.↗

Cavitation Effects on the Structural Dynamics of Turbomachinery Components

The structural integrity of inducer and impeller blades in rocket engine turbomachinery must be evaluated in the face of complex excitation mechanisms including fluctuating pressures due to cavitation. Cavitation occurs when the local fluid pressure drops below the vapor pressure, causing the formation of vapor-filled bubbles. Cavitation can exist to various extents within the typical operating range of rocket engine turbopumps. Despite recent progress towards reducing uncertainties in structural dynamic models of turbomachinery components, the extent to which pump cavitation affects the structural dynamic properties (i.e., natural frequencies, damping, and mode shapes) of inducer and impeller blades remains largely unknown. To study the structural dynamic effects of cavitating flows, experiments are conducted in a high-speed water tunnel. The test article is a low aspect ratio cantilevered plate, thus mimicing a single inducer blade that is unwrapped from its hub. The test article is oriented at zero angle of attack and has a triangular trip at its leading edge to induce cavitation. To change the extent of cavitation, the static pressure of the water tunnel is controlled. A high-speed camera is used to quantify the coverage of the cavitation sheet.

Fluid-Structure Interaction↗

Cavitation Effects on the Structural Dynamics of Turbomachinery Components

The structural integrity of inducer and impeller blades in rocket engine turbo machinery must be evaluated in the face of complex excitation mechanisms including fluctuating pressures due to cavitation. Cavitation occurs when the local fluid pressure drops below the vapor pressure, causing the formation of vapor-filled bubbles. Cavitation can exist to various extents within the typical operating range of rocket engine turbo pumps. Despite recent progress towards reducing uncertainties in structural dynamic models of turbo machinery components, the extent to which pump cavitation affects the structural dynamic properties (i.e., natural frequencies, damping, and mode shapes) of inducer and impeller blades remains largely unknown. To study the structural dynamic effects of cavitating flows, experiments are conducted in a high-speed water tunnel. The test article is a low aspect ratio cantilevered plate, thus mimicing a single inducer blade that is unwrapped from its hub. The test article is oriented at zero angle of attack and has a triangular trip at its leading edge to induce cavitation. To change the extent of cavitation, the static pressure of the water tunnel is controlled. A high-speed camera is used to quantify the coverage of the cavitation sheet.

Structural Dynamics↗

Test and Analysis of Full-Scale 27.5-Foot-Diameter Stiffened Metallic Launch Vehicle Cylinders

The Shell Buckling Knockdown Factor Project (SBKF) was established with the goal of developing improved (i.e., less-conservative, more robust) shell buckling knockdown factors (KDFs) for modern launch-vehicle structures. To this end, SBKF has engaged in several activities to support the development, validation, and implementation of the new design factors, including subscale and full-scale structural testing. Tests on eight different subscale, 8-foot-diameter, integrally stiffened aluminum-lithium 2195 (Al-Li 2195) cylinders were conducted in order to obtain the majority of the required validation data. In addition, two full-scale, 27.5-foot-diameter, Al-Li 2195, integrally stiffened cylinders were tested to provide additional validation data and to determine structural scaling trends. Presented herein are the details of a recent analysis model development and test and analysis correlation effort on the full-scale test articles. The effects of selected modeling assumptions and approaches are discussed, and results from a modeling sensitivity study are presented. It was found that simplified finite element models, that assume nominal test article geometry and material properties, can predict the overall response characteristics well. However, several discrepancies in the test and analysis results were observed. A sensitivity study was performed to determine the effects of several modeling assumptions and address the observed discrepancies. The results from the study indicated that the evolution of local skin pocket buckling and the presence of residual stresses due to the manufacturing process can have a significant influence on the predicted buckling response of the cylinders considered.

Lovejoy, Andrew E.↗

Evaluation of Acoustic Channel Capacity for Complex Piping Topology

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through physical barriers, such as the containment building wall. In addition, this approach provides physical cybersecurity since the pipe becomes an analog communication channel which is difficult to eavesdrop on and difficult to sever. In prior work, a laboratory bench-scale system consisting of a six foot-long straight section of nuclear grade stainless steel pipe and high-temperature ultrasonic LiNbO 3 transducers was assembled. The lab systems was used for communication protocol development and preliminary data transmission demonstration. Next phase of project development involves deployment of the ultrasonic communication system in a representative environment. Mechanisms Engineering Test Loop (METL) facility at ANL was chosen as a viable candidate for communication system demonstration. Analysis of piping manifolds at METL has shown that in a typical scenario, ultrasonic signals have to be transmitted over straight and bent piping sections. This report describes preliminary studies on transmission of information with ultrasonic shear waves across bent piping sections. A test article consisting of a stainless steel pipe bent at 90° was developed for laboratory analysis of ultrasonic signal transmission. The bent piping test article developed by welding two straight pipes to an elbow. For consistency, the diameter and wall thickness of the bent pipe is the same as that of the straight pipe utilized in prior studies. COMSOL computer simulations were performed to study ultrasonic refracted shear wave coupling and transmission across bent piping. Preliminary evaluations of ultrasonic shear wave transmission were conducted with piezoelectric (PZT) and LiNbO 3 transducers, with the signals recorded with previously developed LabView interface. Preliminary results have shown significant dispersion of transmitted signals, most likely due to reflections and scattering by piping welds. Signal distortion compensation algorithm based on time reversal modulation (TRM) was initially investigated for transmission through solids, and demonstrated for signals transmitted over the bent pipe. Using TRM, it was shown that communication bitrates of 100Kbps were achievable, in principle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final Report for Transmission of Information by Acoustic Communication along Metal Pathways in Nuclear Facilities

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively. Preliminary communication system development was performed using paintbrush PZT transducers capable of continuous operation at temperatures up to 80°C. Next, high-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150°C. Final phase of project development involved investigating strategies for deployment of the ultrasonic communication system in a representative environment. Mechanisms Engineering Test Loop (METL) facility at ANL was chosen as a viable candidate for communication system demonstration. Analysis of piping manifolds at METL has shown that in a typical scenario, ultrasonic signals have to be transmitted over straight and bent piping sections. This report describes preliminary studies on transmission of information with ultrasonic shear waves across bent piping sections. A test article consisting of a stainless steel pipe bent at 90° was developed for laboratory analysis of ultrasonic signal transmission. The bent piping test article developed by welding two straight pipes to an elbow. For consistency, the diameter and wall thickness of the bent pipe is the same as that of the straight pipe utilized in prior studies. COMSOL computer simulations were performed to study ultrasonic refracted shear wave coupling and transmission across bent piping. Preliminary evaluations of ultrasonic shear wave transmission were conducted with piezoelectric (PZT) and LiNbO 3 transducers, with the signals recorded with previously developed LabView interface. Preliminary results have shown significant dispersion of transmitted signals, most likely due to reflections and scattering by piping welds. Signal distortion compensation algorithm based on time reversal modulation (TRM) was initially investigated for transmission through solids, and demonstrated for signals transmitted over the bent pipe. Using TRM, it was shown that communication bitrates of 100Kbps were achievable, in principle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Test and Analysis of Buckling-Critical Stiffened Metallic Launch Vehicle Cylinders

A summary of a NASA design analysis and test program on the buckling of large-scale, integrally-stiffened metallic cylinders is presented. The test article designs were developed based on proposed NASA launch vehicle cylinder designs and span a significant portion of the design space. Various loading conditions were applied to the cylinders and include different combinations of axial compression, bending, and internal pressure loads that simulate typical launch vehicle loading scenarios. The data gathered from this test program is being used to develop and validate new analysis-based knockdown factors and design guidelines for these stiffened metallic cylinders. In this paper, the test article designs and fabrication methods are described along with the test facilities and instrumentation. Selected test and finite element analysis results are presented and compared and are used to illustrate the typical response characteristics of the stiffened metallic cylinders considered. Overall, good qualitative agreement is found, however, several discrepancies in the results were identified across several of the tests. The discrepancies were investigated thoroughly and can be attributed to variations in the as-built skin and stiffener geometry, variations in the measured geometric imperfection, and modeling assumptions associated with the boundary conditions, and loading imperfections. Based on these findings, several refinements were made to the finite element models which significantly improved the correlation between the test and analysis results. These modeling refinements are described and the updated analysis results are presented.

Hilburger, Mark W.↗

Conceptual Design and Dynamics Testing and Modeling of a Mars Tumbleweed Rover

The NASA Langley Research Center has been developing a novel concept for a Mars planetary rover called the Mars Tumbleweed. This concept utilizes the wind to propel the rover along the Mars surface, bringing it the potential to cover vast distances not possible with current Mars rover technology. This vehicle, in its deployed configuration, must be large and lightweight to provide the ratio of drag force to rolling resistance necessary to initiate motion from rest on the Mars surface. One Tumbleweed design concept that satisfies these considerations is called the Eggbeater-Dandelion. This paper describes the basic design considerations and a proposed dynamics model of the concept for use in simulation studies. It includes a summary of rolling/bouncing dynamics tests that used videogrammetry to better understand, characterize, and validate the dynamics model assumptions, especially the effective rolling resistance in bouncing/rolling dynamic conditions. The dynamics test used cameras to capture the motion of 32 targets affixed to a test article s outer structure. Proper placement of the cameras and alignment of their respective fields of view provided adequate image resolution of multiple targets along the trajectory as the test article proceeded down the ramp. Image processing of the frames from multiple cameras was used to determine the target positions. Position data from a set of these test runs was compared with results of a three dimensional, flexible dynamics model. Model input parameters were adjusted to match the test data for runs conducted. This process presented herein provided the means to characterize the dynamics and validate the simulation of the Eggbeater-Dandelion concept. The simulation model was used to demonstrate full scale Tumbleweed motion from a stationary condition on a flat-sloped terrain using representative Mars environment parameters.

Calhoun Philip C.↗

Visual Scanning Hartmann Optical Tester (VSHOT) Uncertainty Analysis (Milestone Report)

In 1997, an uncertainty analysis was conducted of the Video Scanning Hartmann Optical Tester (VSHOT). In 2010, we have completed a new analysis, based primarily on the geometric optics of the system, and it shows sensitivities to various design and operational parameters. We discuss sources of error with measuring devices, instrument calibrations, and operator measurements for a parabolic troughmirror panel test. These help to guide the operator in proper setup, and help end-users to understand the data they are provided. We include both the systematic (bias) and random (precision) errors for VSHOT testing and their contributions to the uncertainty. The contributing factors we considered in this study are: target tilt; target face to laser output distance; instrument vertical offset;laser output angle; distance between the tool and the test piece; camera calibration; and laser scanner. These contributing factors were applied to the calculated slope error, focal length, and test article tilt that are generated by the VSHOT data processing. Results show the estimated 2-sigma uncertainty in slope error for a parabolic trough line scan test to be +/-0.2 milliradians;uncertainty in the focal length is +/- 0.1 mm, and the uncertainty in test article tilt is +/- 0.04 milliradians.

14 SOLAR ENERGY↗

Impedance‐matching model‐in‐the‐loop simulation

Abstract Impedance matching is a novel approach to executing model‐in‐the‐loop (MIL) simulations. The concept, key features, and sample applications of this approach have been described in a series of publications. This paper advances theory and implementation for impedance‐matching MIL by: (1) developing a feedback linearization technique for implementing MIL for nonlinear virtual systems, (2) systematically characterizing MIL performance‐stability tradeoffs using three design‐oriented criteria—performance: defined as closeness of the controlled‐actuator impedance to the virtual‐boundary impedance;control effort: low controller response at high frequencies to reduce sensitivity to measurement noise and uncertainties in the actuator model; andstability: pursued using passivity of the controlled actuator system, and (3) assessing, through experimentation, the robustness of two ways to estimate feedback reaction force from the test article. These fundamental advancements to MIL are described using a one‐dimensional configuration consisting of a fluid‐filled cylindrical vessel as the physical test article and a uniaxial hydraulic shake table controlled to imitate different seismic isolation systems at the base of the vessel.

Engineering↗

Strain gauge for testing microreactor hexagonal core blocks in the Single Primary Heat Extraction and Removal Emulator

To support the development and deployment of microreactor technologies, experiments that help verify and validate reactor systems and components are performed at non-nuclear test facilities. The Single Primary Heat Extraction Removal Emulator at Idaho National Laboratory is one of these test facilities and was used to monitor a test article that has a prototypic geometry of a heat-pipe cooled microreactor core block. To collect crucial temperature and strain data during testing, temperature and strain sensing fiber optics were embedded to the surface of the test article using an ultrasonic additive manufacturing technique. To support and provide benchmark strain data for the embedded sensors, a commercial resistive strain gauge was attached. This report will discuss the results from the deployment of the commercial strain gauge which includes the setup/attachment strategies, data acquisition, and analysis of the strain data.

36 MATERIALS SCIENCE↗

Impact of Damping Uncertainty on SEA Model Response Variance

Statistical Energy Analysis (SEA) is commonly used to predict high-frequency vibroacoustic levels. This statistical approach provides the mean response over an ensemble of random subsystems that share the same gross system properties such as density, size, and damping. Recently, techniques have been developed to predict the ensemble variance as well as the mean response. However these techniques do not account for uncertainties in the system properties. In the present paper uncertainty in the damping loss factor is propagated through SEA to obtain more realistic prediction bounds that account for both ensemble and damping variance. The analysis is performed on a floor-equipped cylindrical test article that resembles an aircraft fuselage. Realistic bounds on the damping loss factor are determined from measurements acquired on the sidewall of the test article. The analysis demonstrates that uncertainties in damping have the potential to significantly impact the mean and variance of the predicted response.

Schiller, Noah↗

Contact Thermocouple Methodology and Evaluation for Temperature Measurement in the Laboratory

Laboratory testing of advanced aerospace components very often requires highly accurate temperature measurement and control devices, as well as methods to precisely analyze and predict the performance of such components. Analysis of test articles depends on accurate measurements of temperature across the specimen. Where possible, this task is accomplished using many thermocouples welded directly to the test specimen, which can produce results with great precision. However, it is known that thermocouple spot welds can initiate deleterious cracks in some materials, prohibiting the use of welded thermocouples. Such is the case for the nickel-based superalloy MarM-247, which is used in the high temperature, high pressure heater heads for the Advanced Stirling Converter component of the Advanced Stirling Radioisotope Generator space power system. To overcome this limitation, a method was developed that uses small diameter contact thermocouples to measure the temperature of heater head test articles with the same level of accuracy as welded thermocouples. This paper includes a brief introduction and a background describing the circumstances that compelled the development of the contact thermocouple measurement method. Next, the paper describes studies performed on contact thermocouple readings to determine the accuracy of results. It continues on to describe in detail the developed measurement method and the evaluation of results produced. A further study that evaluates the performance of different measurement output devices is also described. Finally, a brief conclusion and summary of results is provided.

thermocouple↗