Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Projection Chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Searches for decays of new particles in the DUNE Multi-Purpose near Detector

One proposed component of the upcoming Deep Underground Neutrino Experiment (DUNE) near detector complex is a multi-purpose, magnetized, gaseous argon time projection chamber: the Multi-Purpose Detector (MPD). We explore the new-physics potential of the MPD, focusing on scenarios in which the MPD is significantly more sensitive to new physics than a liquid argon detector, specifically searches for semi-long-lived particles that are produced in/near the beam target and decay in the MPD. The specific physics possibilities studied are searches for dark vector bosons mixing kinetically with the Standard Model hypercharge group, leptophilic vector bosons, dark scalars mixing with the Standard Model Higgs boson, and heavy neutral leptons that mix with the Standard Model neutrinos. We demonstrate that the MPD can extend existing bounds in most of these scenarios. We illustrate how the ability of the MPD to measure the momentum and charge of the final state particles leads to these bounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NuGraph2 with context-aware inputs: physics-inspired improvements in semantic segmentation

Graph neural networks have recently shown strong promise for event reconstruction tasks in Liquid Argon Time Projection Chambers, yet their performance remains limited for underrepresented classes of particles, such as Michel electrons. In this work, we investigate physics-informed strategies to improve semantic segmentation within the NuGraph2 architecture. We explore three complementary approaches: (i) enriching the input representation with context-aware features derived from detector geometry and track continuity, (ii) introducing auxiliary decoders to capture class-level correlations, and (iii) incorporating energy-based regularization terms motivated by Michel electron energy distributions. Experiments on MicroBooNE public datasets show that physics-inspired feature augmentation yields the largest gains, particularly boosting Michel electron precision and recall by disentangling overlapping latent space regions. In contrast, auxiliary decoders and energy-regularization terms provided limited improvements, partly due to the hit-level nature of NuGraph2, which lacks explicit particle- or event-level representations. Our findings highlight that embedding physics context directly into node-level inputs is more effective than imposing task-specific auxiliary losses, and suggest that future hierarchical architectures such as NuGraph3, with explicit particle- and event-level reasoning, will provide a more natural setting for advanced decoders and physics-based regularization. The code for this work is publicly available on Github at https://github.com/vitorgrizzi/nugraph_phys/tree/main_phys.

Other Experiments↗

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffusion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the scintillation region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of NEXT-100 to neutrinoless double beta decay

NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta (0νββ) decay of $^{136}$Xe. The detector possesses two features of great value for 0νββ searches: energy resolution better than 1% FWHM at the Q value of $^{136}$Xe and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most 4 × 10$^{–4}$ counts keV$^{–1}$ kg$^{–1}$ yr$^{–1}$. Furthermore, the detector will reach a sensitivity to the 0νββ-decay half-life of 2.8 × 10$^{25}$ years (90% CL) for an exposure of 100 kg·year, or 6.0 × 10$^{25}$ years after a run of 3 effective years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DUNE atmospheric neutrinos: Earth tomography

In this paper we show that the DUNE experiment can measure the Earth’s density profile by analyzing atmospheric neutrino oscillations. The crucial feature that enables such measurement is the detailed event reconstruction capability of liquid argon time projection chambers. This allows for studying the sub-GeV atmospheric neutrino component, which bears a rich oscillation phenomenology, strongly dependent on the matter potential sourced by the Earth. We provide a pedagogical discussion of the MSW and parametric resonances and their role in measuring the core and mantle densities. By performing a detailed simulation, accounting for particle reconstruction at DUNE, nuclear physics effects relevant to neutrino-argon interactions and several uncertainties on the atmospheric neutrino flux, we manage to obtain a robust estimate of DUNE’s sensitivity to the Earth matter profile. We find that DUNE can measure the total mass of the Earth at 9.3% precision with an exposure of 400 kton-year. By accounting for previous measurements of the total mass and moment of inertia of the Earth, the core, lower mantle and upper mantle densities can be determined with 9%, 14% and 22% precision, respectively, for the same exposure. Finally, for a low exposure run of 60 kton-year, which would correspond to two far detectors running for three years, we have found that the core density could be measured by DUNE at ∼ 30% precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of energy resolution with the NEXT-White silicon photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}$Kr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 ± 0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the 0νββ decay using a high-pressure $^{136}$Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal $^{222}$Rn activity is found to be (0.95±0.04(stat)±0.09(sys)) Bq/m$^{3}$, while no traces of $^{220}$Rn have been observed. Most of the $^{222}$Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced $^{214}$Bi of (0.97±0.05(stat)±0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0νββ region of interest is evaluated as (7.3±1.5(stat)±0.8(sys))×10$^{−4}$ counts/(keV·kg·yr) after selection of the fully contained events. This background index is reduced to ∼4×10$^{−5}$ counts/(keV·kg·yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.[graphic not available: see fulltext]

Cortes-Parra, C. [Valencia U., IFIC] (ORCID:000000↗

Measurement of radon-induced backgrounds in the NEXT double beta decay experiment

Here, the measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by $^{222}$Rn and its alpha-emitting progeny. The specific activity is measured to be $(38.1\pm 2.2~\mathrm{(stat.)}\pm 5.9~\mathrm{(syst.)})$~mBq/m$^3$. Radon-induced electrons have also been characterized from the decay of the $^{214}$Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.1~counts/yr in the neutrinoless double beta decay sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing energetic light dark matter with multi-particle tracks signatures at DUNE

The search for relativistic scattering signals of cosmogenic light dark matter at terrestrial detectors has received increasing attention as an alternative approach to probe dark-sector physics. Large-volume neutrino experiments are well motivated for searches of dark matter that interacts very weakly with Standard Model particles and/or that exhibits a small incoming flux. We perform a dedicated signal sensitivity study for a detector similar to the one proposed by the DUNE Collaboration for cosmogenic dark-matter signals resulting from a non-minimal multi-particle dark-sector scenario. The liquid argon time projection chamber technology adopted for the DUNE detectors is particularly suited for searching for complicated signatures owing to good measurement resolution and particle identification, as well as dE/dx measurements to recognize merged tracks. Taking inelastic boosted dark matter as our benchmark scenario that allows for multiple visible particles in the final state, we demonstrate that the DUNE far detectors have a great potential for probing scattering signals induced by relativistic light dark matter. Detector effects and backgrounds have been estimated and taken into account. Model-dependent and model-independent expected sensitivity limits for a DUNE-like detector are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calorimetric classification of track-like signatures in liquid argon TPCs using MicroBooNE data

The MicroBooNE liquid argon time projection chamber located at Fermilab is a neutrino experiment dedicated to the study of short-baseline oscillations, the measurements of neutrino cross sections in liquid argon, and to the research and development of this novel detector technology. Accurate and precise measurements of calorimetry are essential to the event reconstruction and are achieved by leveraging the TPC to measure deposited energy per unit length along the particle trajectory, with mm resolution. We describe the non-uniform calorimetric reconstruction performance in the detector, showing dependence on the angle of the particle trajectory. Such non-uniform reconstruction directly affects the performance of the particle identification algorithms which infer particle type from calorimetric measurements. This work presents a new particle identification method which accounts for and effectively addresses such non-uniformity. The newly developed method shows improved performance compared to previous algorithms, illustrated by a 93.7% proton selection efficiency and a 10% muon mis-identification rate, with a fairly loose selection of tracks performed on beam data. The performance is further demonstrated by identifying exclusive final states in ν μ CC interactions. While developed using MicroBooNE data and simulation, this method is easily applicable to future LArTPC experiments, such as SBND, ICARUS, and DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of ACTS into sPHENIX Track Reconstruction

Abstract sPHENIX is a high energy nuclear physics experiment under construction at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory (BNL). The primary physics goals of sPHENIX are to study the quark-gluon-plasma, as well as the partonic structure of protons and nuclei, by measuring jets, their substructure, and heavy flavor hadrons in $$p$$ p $$+$$ + $$p$$ p , p + Au, and Au + Au collisions. sPHENIX will collect approximately 300 PB of data over three run periods, to be analyzed using available computing resources at BNL; thus, performing track reconstruction in a timely manner is a challenge due to the high occupancy of heavy ion collision events. The sPHENIX experiment has recently implemented the A Common Tracking Software (ACTS) track reconstruction toolkit with the goal of reconstructing tracks with high efficiency and within a computational budget of 5 s per minimum bias event. This paper reports the performance status of ACTS as the default track fitting tool within sPHENIX, including discussion of the first implementation of a time projection chamber geometry within ACTS.

97 MATHEMATICS AND COMPUTING↗

Dual MeV gamma-ray and dark matter observatory - GRAMS Project

GRAMS (Gamma-Ray and AntiMatter Survey) is a new project that can simultaneously target both astrophysical observations with MeV gamma rays and an indirect dark matter search with antimatter. The GRAMS instrument is designed with a cost-effective, large-scale LArTPC (Liquid Argon Time Projection Chamber) detector surrounded by plastic scintillators. The astrophysical observations at MeV energies have not yet been investigated (the so-called “MeV-gap”) and GRAMS can improve the sensitivity by more than an order of magnitude compared to previous experiments. While primarily focusing on MeV gamma-ray observations, GRAMS is also optimized for cosmic ray antimatter surveys to indirectly search for dark matter. In particular, low-energy antideuterons will provide an essentially background-free dark matter signature. GRAMS will be a next generation experiment beyond the current GAPS (General AntiParticle Spectrometer) project for antimatter survey.

79 ASTRONOMY AND ASTROPHYSICS↗

TRANSLATE - a Monte Carlo simulation of electron transport in liquid argon

Here, the microphysics of electron and photon propagation in liquid argon is a key component of detector design and calibrations needed to construct and perform measurements within a wide range of particle physics experiments. As experiments grow in scale and complexity, and as the precision of their intended measurements increases, the development of tools to investigate important microphysics effects impacting such detectors becomes necessary. In this paper we present a new time-domain Monte Carlo simulation of electron transport in liquid argon. The simulation models the TRANSport in Liquid Argon of near-Thermal Electrons (TRANSLATE) with the aim of providing a multi-purpose software package for the study and optimization of detector environments, with a particular focus on ongoing and next generation liquid argon neutrino experiments utilizing the time projection chamber technology. TRANSLATE builds on previous work of Wojcik and Tachiya, amongst others, introducing additional processes, including ionization, thus modeling the full range of drift electron scattering interactions. The simulation is validated by benchmarking its performance with swarm parameters from data collected in experimental setups operating in gas and liquid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An RF-only ion-funnel for extraction from high-pressure gases

An RF ion-funnel technique has been developed to extract ions from a high-pressure (10 bar) noble-gas environment into a vacuum (10 -6 mbar). Detailed simulations have been performed and a prototype has been developed for the purpose of extracting 136 Ba ions from Xe gas with high efficiency. With this prototype, ions have been extracted for the first time from high-pressure xenon gas and argon gas. Systematic studies have been carried out and compared to simulations. This demonstration of extraction of ions, with mass comparable to that of the gas generating the high-pressure, has applications to Ba tagging from a Xe-gas time-projection chamber for double-beta decay, as well as to the general problem of recovering trace amounts of an ionized element in a heavy (m > 40 u) carrier gas.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stopping Force Analysis of 235 U Elemental Fission Product Yields for $E_n$ = 0.11–92.4 MeV

We report most evaluated elemental fission product yield distributions are not experimentally measured. Instead, the majority of evaluated distributions are based on analytic expressions of the Zp-model for relevant cumulative yields. Here we report independent elemental fission product yield distributions of a 235 U target for incident neutron energies ranging from 0.11 MeV through 92.4 MeV. Atomic numbers are calculated by an approach that combines a 2E analysis with a stopping force analysis method, developed within this paper. These analyses are applied to more than 6.1 × 10 6 fission fragment ionization tracks captured within the NIFFTE (Neutron Induced Fission Fragment Tracking Experiment) collaboration fission time projection chamber (fissionTPC). A 3-Z resolution was obtained with the fissionTPC spatial and energy resolutions. Tabulated results are presented for the atomic yield and experimentally derived Zp values as a function of pre-neutron-emission fragment masses for the complete range of incident neutron energies. The stopping-force-derived Zp values tend to support the unchanged charge distribution theory within uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The LUX prototype detector: Heat exchanger development

The LUX (large underground xenon) detector is a two-phase xenon time projection chamber (TPC) designed to search for WIMP–nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large (> 1 ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for achieving robust discrimination of signal from background events. Here, we describe the development of a novel purification system deployed in a prototype detector. The results from the operation of this prototype indicated heat exchange with an efficiency above 94% up to a flow rate of 42 slpm, allowing for an electron drift length greater than 1 m to be achieved in approximately 2 days and sustained for the duration of the testing period.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A low-noise CMOS pixel direct charge sensor, Topmetal-II -

In this paper, we report the design and characterization of a CMOS pixel direct charge sensor, Topmetal-II-, fabricated in a standard 0.35 μm CMOS Integrated Circuit process. The sensor utilizes exposed metal patches on top of each pixel to directly collect charge. Each pixel contains a low-noise charge-sensitive preamplifier to establish the analog signal and a discriminator with tunable threshold to generate hits. The analog signal from each pixel is accessible through time-shared multiplexing over the entire array. Hits are read out digitally through a column-based priority logic structure. Tests show that the sensor achieved a <15e - analog noise and a 200e - minimum threshold for digital readout per pixel. The sensor is capable of detecting both electrons and ions drifting in gas. Lastly, these characteristics enable its use as the charge readout device in future Time Projection Chambers without gaseous gain mechanism, which has unique advantages in low background and low rate-density experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of wire tension measurement system for MWPCs used in the STAR iTPC upgrade

The STAR experiment at RHIC is planning to upgrade the Time Projection Chamber which lies at the heart of the detector. We have designed an instrument to measure the tension of the wires in the multi-wire proportional chambers (MWPCs) which will be used in the TPC upgrade. The wire tension measurement system causes the wires to vibrate and then it measures the fundamental frequency of the oscillation via a laser based optical platform. The platform can scan the entire wire plane, automatically, in a single run and obtain the wire tension on each wire with high precision. In this paper, the details about the measurement method and the system setup will be described. In addition, the test results for a prototype MWPC to be used in the STAR-iTPC upgrade will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗