Search NASA⌕ Search

SEARCH · Search NASA

Results for “VALVES - OVERLAP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Space Shuttle Main Propulsion System Gaseous Hydrogen Flow Control Valve Poppet Failure

The presentation provides background information pertinent to the MPS GH2 Flow Control Valve Poppet failure which occurred on the Space Shuttle Endeavour during STS-126 flight. The presentation provides general MPS system operating information which is pertinent to understanding the failure causes and affects. The presentation provides additional background information on the operating environment in which the FCV functions and basic design history of the flow control valve. The presentation provides an overview of the possible flight failure modes and a brief summary of the flight rationale which was developed for this failure event. This presentation is an introductory presentation to 3 other speakers at the conference who will be speaking on M&P aspects of the investigation, non destructive inspection techniques development, and particle impact testing.

Zeitler, Rick↗

Lessons Learned from the Space Shuttle Engine Hydrogen Flow Control Valve Poppet Breakage

The Main Propulsion System (MPS) uses three Flow Control Valves (FCV) to modulate the flow of pressurant hydrogen gas from the Space Shuttle Main Engines (SSME) to the hydrogen External Tank (ET). This maintains pressure in the ullage volume as the liquid level drops, preserving ET structural integrity and assuring the engines receive a sufficient amount of head pressure. On Space Transportation System (STS)-126 (2009), with only a handful of International Space Station (ISS) assembly flights from the end of the Shuttle program, a portion of a single FCV?s poppet head broke off at about a minute and a half after liftoff. The risk of the poppet head failure is that the increased flow area through the FCV could result in excessive gaseous hydrogen flow back to the external tank, which could result in overboard venting of hydrogen ullage pressure. If the hydrogen venting were to occur in first stage (i.e., lower atmosphere), a flammability hazard exists that could lead to catastrophic loss of crew and vehicle. Other failure risks included particle impact damage to MPS downstream hardware. Although the FCV design had been plagued by contamination-related sluggish valve response problems prior to a redesign at STS-80 (1996), contamination was ruled out as the cause of the STS-126 failure. Employing a combination of enhanced hardware inspection and a better understanding of the consequences of a poppet failure, safe flight rationale for subsequent flights (STS-119 and later) was achieved. This paper deals with the technical lessons learned during the investigation and mitigation of this problem at a time when assembly flights were each in the critical path to Space Station success.

Martinez, Hugo E.↗

Rapid-Chill Cryogenic Coaxial Direct-Acting Solenoid Valve

A commercially available cryogenic direct- acting solenoid valve has been modified to incorporate a rapid-chill feature. The net effect of the modifications is to divert some of the cryogenic liquid to the task of cooling the remainder of the cryogenic liquid that flows to the outlet. Among the modifications are the addition of several holes and a gallery into a valve-seat retainer and the addition of a narrow vent passage from the gallery to the atmosphere.

Richard, James↗

Stemless ball valve

A stemless ball valve comprising two flanges and a ball with a channel, two axis pins and two travel pins. One end of each axis and travel pin is fixedly attached to the ball, and the other end of each axis pin is lodged into a notch in the first or second flange such that the axis pin is allowed to rotate in the notch. The guide sleeve comprises two channels, and one end of each travel pin is situated within one of the two channels in the guide sleeve. An outer magnetic cartridge causes the inner magnetic cartridge and guide sleeve to rotate, and when the guide sleeve rotates, the travel pins move up and down within the channels in the guide sleeve. The movement of the travel pins within the channels in the guide sleeve causes the ball to rotate, thereby opening and closing the ball valve.

Burgess, Kevin↗

Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link

Future lunar landers and rovers will require variable thermal links that allow for heat rejection during the lunar daytime and passively prevent heat rejection during the lunar night. During the lunar day, the thermal management system must reject the waste heat from the electronics and batteries to maintain them below the maximum acceptable temperature. During the lunar night, the heat rejection system must either be shut down or significant amounts of guard heat must be added to keep the electronics and batteries above the minimum acceptable temperature. Since guard heater power is unfavorable because it adds to system size and complexity, a variable thermal link is preferred to limit heat removal from the electronics and batteries during the long lunar night. Conventional loop heat pipes (LHPs) can provide the required variable thermal conductance, but they still consume electrical power to shut down the heat transfer. This innovation adds a thermal control valve (TCV) and a bypass line to a conventional LHP that proportionally allows vapor to flow back into the compensation chamber of the LHP. The addition of this valve can achieve completely passive thermal control of the LHP, eliminating the need for guard heaters and complex controls.

Hartenstine, John↗

Dynamic Mechanical Analysis (DMA) to Help Characterize Vespel SP-211 Polyimide Material for Use as a 750 F Valve Seal on the Ares I Upper Stage J-2X Engine

DuPont (TM) Vespel (R) SP-211 polyimide was selected as the top candidate seal material for use in the Oxidizer Turbine Bypass Valve (OTBV) on NASA's Ares I Upper Stage J-2X engine. In the OTBV, the seal material would get exposed to temperatures up to 750degF for approx 10 minutes at a time. Although the J-2X engine is not reusable, the valve material could be exposed to multiple temperature cycles up to 750 F during engine operation. The Constellation Program that included the Ares I rocket was eventually cancelled, but the J-2X engine was chosen for continued use for development of NASA's Space Launch System (SLS). The SLS is a heavy-lift launch vehicle that will have capability of taking astronauts and hardware to the Moon, Mars and asteroids. Dynamic mechanical analysis (DMA) was one of several test techniques used to characterize Vespel SP-211 to help prove its worthiness for use on the OTBV of the J-2X engine.

Wingard, Doug↗

Dynamic Mechanical Analysis (DMA) to Help Characterize Vespel SP-211 Polyimide Material for Use as a 750 F Valve Seal on the Ares I Upper Stage J-2X Engine

DuPont(tm) Vespel(R) SP-211 polyimide was selected as the top candidate seal material for use in the Oxidizer Turbine Bypass Valve (OTBV) on NASA's Ares I Upper Stage J-2X engine. In the OTBV, the seal material would get exposed to temperatures up to 750degF for approx 10 minutes at a time. Although the J-2X engine is not reusable, the valve material could be exposed to multiple temperature cycles up to 750degF during engine operation. The Constellation Program that included the Ares I rocket was eventually cancelled, but the J-2X engine was chosen for continued use for development of NASA's Space Launch System (SLS). The SLS is a heavy-lift launch vehicle that will have capability of taking astronauts and hardware to the Moon, Mars and asteroids. Dynamic mechanical analysis (DMA) was one of several test techniques used to characterize Vespel SP-211 to help prove its worthiness for use on the OTBV of the J-2X engine.

Wingard, Doug↗

Magnetically Retained Relief Valve

A pressure relief valve includes a housing having a fluid inlet and at least one fluid outlet. A first structure mounted in the housing and fixed in relation thereto is in magnetic attraction with a second structure coupled to a piston disposed in a portion of the housing. The piston defines a chamber disposed adjacent to the fluid outlet(s) throughout the piston's stroke. The piston includes a sealing element providing a sealing force to prevent flow through the valve. The sealing force is independent of the magnetic attraction force between the first and second structures.

Johnson, Wesley L.↗

Sliding pressure control valve for pneumatic hammer drill

A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.

42 ENGINEERING↗

Piezoelectric valve

A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

42 ENGINEERING↗

System for detecting operating errors in a variable valve timing engine using pressure sensors

A method and control module includes a pressure sensor data comparison module that compares measured pressure volume signal segments to ideal pressure volume segments. A valve actuation hardware remedy module performs a hardware remedy in response to comparing the measured pressure volume signal segments to the ideal pressure volume segments when a valve actuation hardware failure is detected.

47 OTHER INSTRUMENTATION↗

Phase-change valves and related methods

Valves may include an opening sized and shaped to permit a subject fluid to flow through the opening when the opening is unobstructed. A heat exchange element may be located proximate to the opening, the heat exchange element positioned and configured to induce a localized phase change in the subject fluid to form and unform a solid plug from the subject fluid around at least a portion of the heat exchange element. A heat transfer rate of the heat exchange element may be variable to control a rate of flow of the subject fluid through the valve by controlling a size of the solid plug from the subject fluid.

Sabharwall, Piyush↗

Enhanced Component Performance Study: Air-Operated Valves 1998–2013

This report presents a performance evaluation of air-operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2013 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The AOV failure modes considered are failure-to-open/close, failure to operate or control, and spurious operation. The component reliability estimates and the reliability data are trended for the most recent 10-year period, while yearly estimates for reliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the AOV failure data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dual-time-point FDG PET/CT imaging in prosthetic heart valve endocarditis

Purpose: FDG PET/CT has been of increasing interest in the diagnostic workup of prosthetic heart valve endocarditis (PVE). Some reports advocate later imaging time points to improve the diagnostic accuracy for PVE. In this study, we compared standard and late FDG PET/CT images in patients with a clinical suspicion of PVE. Materials and Methods: Fourteen scans in 13 patients referred for FDG PET/CT for suspicion of PVE performed at standard (60 min post injection) and late (150 min post injection) time points were scored based on visual interpretation and semi-quantitatively with SUVmax and target-to-background ratio (TBR, defined as [SUVmax valve/SUVmean blood pool]). Final diagnosis was based on surgical findings in all cases of infection (n = 6) and unremarkable follow-up in all others (n = 8). Results: Late images were more prone to false positive interpretation for both visual and semi-quantitative analyses. Visual analysis of the standard images yielded 1 false negative and 1 false positive result. On the late images, no scans were false negative but 5 scans were false positive. Conclusion: Late FDG PET/CT imaging for PVE seems prone to false positive results. Therefore, late imaging should be interpreted with caution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reliable statistics-based detection and investigation of anomalies in a SMART valve system

Reliable anomaly detection and diagnosis are critical for the safe operation of complex engineered systems. This study presents a unified framework that integrates statistical, model-based, and data-driven techniques for anomaly detection and investigation, demonstrated on SMART valve systems in hybrid energy applications. Four detection methods—mean deviation, seasonal extreme studentized deviate, ARIMA forecasting, and matrix profiling—were implemented and compared. Matrix profiling was particularly effective in revealing subtle deviations and hidden relationships among variables. Anomaly investigation was performed by analyzing variable-level and grouped signal profiles, with system topology incorporated to distinguish primary faults from propagated effects. Grouping signals by type enhanced interpretability, enabling accurate localization of anomalies across multi-dimensional datasets. Experimental results confirmed the framework's capability to consistently detect and isolate anomalies while providing actionable insights into system interdependencies. The proposed methodology offers a robust, interpretable, and scalable solution for condition monitoring, with potential applications in safety-critical domains such as nuclear energy, aerospace, and process industries.

ARIMA models↗