Search NASA⌕ Search

SEARCH · Search NASA

Results for “VOLTAGE AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Automated Cryocooler Monitor and Control System

A system was designed to automate cryogenically cooled low-noise amplifier systems used in the NASA Deep Space Network. It automates the entire operation of the system including cool-down, warm-up, and performance monitoring. The system is based on a single-board computer with custom software and hardware to monitor and control the cryogenic operation of the system. The system provides local display and control, and can be operated remotely via a Web interface. The system controller is based on a commercial single-board computer with onboard data acquisition capability. The commercial hardware includes a microprocessor, an LCD (liquid crystal display), seven LED (light emitting diode) displays, a seven-key keypad, an Ethernet interface, 40 digital I/O (input/output) ports, 11 A/D (analog to digital) inputs, four D/A (digital to analog) outputs, and an external relay board to control the high-current devices. The temperature sensors used are commercial silicon diode devices that provide a non-linear voltage output proportional to temperature. The devices are excited with a 10-microamp bias current. The system is capable of monitoring and displaying three temperatures. The vacuum sensors are commercial thermistor devices. The output of the sensors is a non-linear voltage proportional to vacuum pressure in the 1-Torr to 1-millitorr range. Two sensors are used. One measures the vacuum pressure in the cryocooler and the other the pressure at the input to the vacuum pump. The helium pressure sensor is a commercial device that provides a linear voltage output from 1 to 5 volts, corresponding to a gas pressure from 0 to 3.5 MPa (approx. = 500 psig). Control of the vacuum process is accomplished with a commercial electrically operated solenoid valve. A commercial motor starter is used to control the input power of the compressor. The warm-up heaters are commercial power resistors sized to provide the appropriate power for the thermal mass of the particular system, and typically provide 50 watts of heat. There are four basic operating modes. "Cool " mode commands the system to cool to normal operating temperature. "Heat " mode is used to warm the device to a set temperature near room temperature. "Pump " mode is a maintenance function that allows the vacuum system to be operated alone to remove accumulated contaminants from the vacuum area. In "Off " mode, no power is applied to the system.

Britcliffe, Michael J.↗

Electromagnetic calorimeter for the Heavy Photon Search Experiment at Jefferson Lab

The Heavy Photon Search Experiment (HPS) seeks to detect a hypothesised hidden sector boson, the A', predicted to be produced in dark matter decay or annihilation. Theories suggest that the A' couples weakly to electric charge through kinetic mixing, allowing it, as a result, to decay to Standard Matter (SM) lepton pair, which may explain the electron and positron excess recently observed in cosmic rays. Measuring the lepton pair decay of the A' could lead to indirect detection of dark matter. The HPS experiment is a fixed target experiment that will utilize the electron beam produced at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The detector set-up includes a silicon vertex tracker (SVT) and an Electromagnetic Calorimeter (ECal). The ECal will provide the trigger and detect e+e- pairs and its construction and testing forms the focus of this thesis. The ECal consists of 442 PbWO 4 - tapered crystals with a length 16cm and a 1.6x1.6cm 2 cross-section, stacked into a rectangular array and are coupled to Large Area APDs and corresponding pre-amplifiers. Supplementary to the ECal is a Light Monitoring System (LMS) consisting of bi-coloured LEDs that will monitor changes in APD gain and crystal transparency due to radiation damage. Before construction of the ECal each of the components were required to be individually tested to determine a number of different characteristics. Irradiation tests were performed on PbWO 4 ECal crystals and, as a comparison, one grown by a different manufacturer to determine their radiation hardness. A technique for annealing the radiation damage by optical bleaching, which involves injecting light of various wavelengths into the crystal, was tested using the blue LED from the LMS as a potential candidate. The light yield dependence on temperature was also measured for one of the PbWO 4 crystal types. Each APD was individually tested to determine if they functioned correctly and within the requirements of the experiment, then arranged into groups of similar gain at chosen applied voltages, for connection to High Voltage (HV) supplies. Each bi-coloured LED was also tested to determine if they functioned within the specifications of the experiment; including their signal quality at high frequency and their radiation hardness. The HPS crystals were recycled from a previous Jefferson Lab detector, the Inner Calorimeter from CLAS, which needed to be dismantled and reconditioned using various removal and cleaning techniques. The HPS ECal was then constructed in a new formation using a combination of different gluing and construction techniques, and initial functionality tests were performed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron Transport by a Transverse Acoustoelectric Stoneley Wave

The effect of acoustoelectric charge transport is associated with the possibility of amplifying acoustoelectric waves using an external electric field and has been studied in detail for body and surface waves. Electron transport by a transverse acoustoelectric wave (e.g., a Stoneley wave propagating along the heterojunction of two piezoelectric semiconductor layers) is considered in this work for the first time. Analytical expressions for the acoustic conductivity tensor components are derived that depend on the wave phase velocity and electron drift velocity in an external electric field. It is shown that the alternating acoustoelectric current is a sum of two surface currents: the drift current, which depends linearly on the external electric field, and the current that depends nonlinearly on this field. An expression for the acoustoelectric electron mobility is derived. It is found that the acoustoelectric current induced by an electron density wave grows infinitely when the electron drift velocity becomes equal to the wave phase velocity. The analytical expressions obtained for the mobility and current density can be used in calculating current–voltage characteristics of Stoneley wave acoustoelectric field-effect transistors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NASA Tech Briefs, September 2009

opics covered include: Filtering Water by Use of Ultrasonically Vibrated Nanotubes; Computer Code for Nanostructure Simulation; Functionalizing CNTs for Making Epoxy/CNT Composites; Improvements in Production of Single-Walled Carbon Nanotubes; Progress Toward Sequestering Carbon Nanotubes in PmPV; Two-Stage Variable Sample-Rate Conversion System; Estimating Transmitted-Signal Phase Variations for Uplink Array Antennas; Board Saver for Use with Developmental FPGAs; Circuit for Driving Piezoelectric Transducers; Digital Synchronizer without Metastability; Compact, Low-Overhead, MIL-STD-1553B Controller; Parallel-Processing CMOS Circuitry for M-QAM and 8PSK TCM; Differential InP HEMT MMIC Amplifiers Embedded in Waveguides; Improved Aerogel Vacuum Thermal Insulation; Fluoroester Co-Solvents for Low-Temperature Li+ Cells; Using Volcanic Ash to Remove Dissolved Uranium and Lead; High-Efficiency Artificial Photosynthesis Using a Novel Alkaline Membrane Cell; Silicon Wafer-Scale Substrate for Microshutters and Detector Arrays; Micro-Horn Arrays for Ultrasonic Impedance Matching; Improved Controller for a Three-Axis Piezoelectric Stage; Nano-Pervaporation Membrane with Heat Exchanger Generates Medical-Grade Water; Micro-Organ Devices; Nonlinear Thermal Compensators for WGM Resonators; Dynamic Self-Locking of an OEO Containing a VCSEL; Internal Water Vapor Photoacoustic Calibration; Mid-Infrared Reflectance Imaging of Thermal-Barrier Coatings; Improving the Visible and Infrared Contrast Ratio of Microshutter Arrays; Improved Scanners for Microscopic Hyperspectral Imaging; Rate-Compatible LDPC Codes with Linear Minimum Distance; PrimeSupplier Cross-Program Impact Analysis and Supplier Stability Indicator Simulation Model; Integrated Planning for Telepresence With Time Delays; Minimizing Input-to-Output Latency in Virtual Environment; Battery Cell Voltage Sensing and Balancing Using Addressable Transformers; Gaussian and Lognormal Models of Hurricane Gust Factors; Simulation of Attitude and Trajectory Dynamics and Control of Multiple Spacecraft; Integrated Modeling of Spacecraft Touch-and-Go Sampling; Spacecraft Station-Keeping Trajectory and Mission Design Tools; Efficient Model-Based Diagnosis Engine; and DSN Simulator.

Source record↗

Novel Electron-Bubble Tracking Detectors

Our Columbia group, in collaboration with Brookhaven and SMU, has been carrying out R&D on tracking detectors in cryogenic liquids, including neon and helium. A cryostat purchased by this Grant capable of working temperatures down to 1 K and pressures above the critical point of neon and helium has been operated with a variety of noble fluids. Gaseous Electron Multipliers (GEM) with hydrogen additives have been operated with tracks of radioactive sources read out both by electrical charge detecting electronics, and an optical camera purchased by this Grant, measuring mobility, charge yield, transitions through phase boundaries, gain limitations, and other properties. The goal is very high resolution in large volumes. The scope of the project is the provision of a high performance camera and its installation in a cryogenic facility providing pressure up to 40 atmospheres and a temperature from ambient down to about 1 K. In this section we will address the goals and results having to do with this project and particularly the performance of the camera, and provide a summary of the status of the detector project. The technical development of digital cameras has been dominated for the last forty years by the Charge-Coupled Device technology (CCD). This allows photon recording on very small pixels on silicon planes that provide high quantum efficiency in the visible spectrum, recording the charge generated by a single photon stored on one pixel with an area of order ten microns square. The area can be up to several centimeters squared, containing a million pixels or more. The stores charge is usually read out by manipulating voltage biases to shift the charge in each pixel over to the next, and eventually out of the array and sent to an external processor and memory. Mass production has brought the cost per channel down to very small values and allowed cameras to be integrated to many consumer products. Thermal noise becomes larger than one photon on a single pixel at good temperature, and demand night vision and other demanding applications has led to intense R&D over the years, and small coolers that maintain the CCD at temperatures of more than 100K below ambient are integrated into the camera package. These systems are sold in quantity to amateur astronomers with the same silicon devices used in professional systems, provided long exposure times with less than one electron noise per pixel. In our particle readout, we are imaging a three-dimensional track drifting into the readout plane over time, and we need to read out one plane after another, and we need a high rate of pixel processing. For many years, the noise in the electronic amplifier matching the CCD to the external electronics led to noise levels of many electrons, much higher than in the CCD itself. A break-through was made by providing signal gain inside the CCD, connecting to the external line, by a Electron Multiplier CCD, using a number of electron avalanche stages, each with a small, stable gain. This device was brought out just before out application for the present Grant, provided the last link in the development chain, which allowed out optical readout concept to be implemented at reason fact. In fact, we profited from the falling cost by delaying our order for about a year, which, together with the university discount, allowed us to proceed within our budget. The camera we purchase from the firm ANDOR, which introduced the technique, comes with an extensive suite of software that allows the fast readout with different integration times, and makes a very convenient use in our application. We have been able to make images of the light signals coming from out GEM electron avalanche detectors under many conditions, with tracks of different particle types. We have reconfigured the system a number of times, using the results from the camera to learn how to change the TPC drift geometry and the GEM charge amplifier to improve performance, a process that is still going on. The camera purchase with this Grant has performed reliably and just as specified by the manufacturer and has been a trouble-free element of our larger product. The ability of being able to vary the pressure and temperature over a wide range is very important for several reasons: (1) we are able to choose a fluid density to make the best compromise between a range of low energy tracks long enough to measure, and higher density to minimize the detector size for a given rate; (2) we can identify the density the allows the avalanche rate that provides sufficient signal to noise for the low-energy tracks we need to measure in a given application; and (3) we can operate at the optimum density and hydrogen admixture for light production. A special cryostat was required to operate down to 1 K with pressures up to 40 Bar, well above the critical point of Neon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Real-time Modulation Control System on the JT-60U ECRF System

A real-time modulation control system was developed for studying the effectiveness of modulated Electron Cyclotron Current Drive (ECCD) on the stabilization of Neoclassical Tearing Modes (NTMs). The phase and duty cycle tracking was enabled with high accuracy even if the NTM frequency varied during ECCD. A characteristic of an anode voltage modulation for modulating the gyrotron oscillation that caused the time variation of the phase and duty cycle was also taking into account. It was shown that the phase and duty cycle could be kept the target values within 50 ms even if the frequency varied by 1 kHz/s or higher at a frequency of around 5 kHz. Then, NTM stabilization experiments with modulated ECCD for m/n = 2/1 NTM was successfully performed in JT-60U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetron injection gun for a broadband gyrotron backward-wave oscillator

The magnetron injection gun is capable of generating relativistic electron beam with high velocity ratio and low velocity spread for a gyrotron backward-wave oscillator (gyro-BWO). However, the velocity ratio ({alpha}) varies drastically against both the magnetic field and the beam voltage, which significantly limits the tuning bandwidth of a gyro-BWO. This study remedies this drawback by adding a variable trim field to adjust the magnetic compression ratio when changing the operating conditions. Theoretical results obtained by employing a two-dimensional electron gun code (EGUN) demonstrate a constant velocity ratio of 1.5 with a low axial velocity spread of 6% from 3.4-4.8 Tesla. These results are compared with a three-dimensional particle-tracing code (computer simulation technology, CST). The underlying physics for constant {alpha} will be discussed in depth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vapor-Phase-Gating-Induced Ultrasensitive Ion Detection in Graphene and Single-Walled Carbon Nanotube Networks

Designing ultrasensitive detectors often requires complex architectures, high-voltage operations, and sophisticated low-noise measurements. Here, it is shown that simple low-bias two-terminal DC-conductance values of graphene and single-walled carbon nanotubes are extremely sensitive to ionized gas molecules. Incident ions form an electrode-free, dielectric- or electrolyte-free, bias-free vapor-phase top-gate that can efficiently modulate carrier densities up to ≈0.6 × 10 13 cm -2 . Surprisingly, the resulting current changes are several orders of magnitude larger than that expected from conventional electrostatic gating, suggesting the possible role of a current-gain inducing mechanism similar to those seen in photodetectors. These miniature detectors demonstrate charge–current amplification factor values exceeding 10 8 A C -1 in vacuum with undiminished responses in open air, and clearly distinguish between positive and negative ions sources. At extremely low rates of ion incidence, detector currents show stepwise changes with time, and calculations suggest that these stepwise changes can result from arrival of individual ions. Lastly, these sensitive ion detectors are used to demonstrate a proof-of-concept low-cost, amplifier-free, light-emitting-diode-based low-power ion-indicator.

36 MATERIALS SCIENCE↗

Digital Twin User Guide for Chelan County Public Utility District

This user manual offers a comprehensive guide for developing a Digital twin (DT) of a Kaplan turbine at Chelan County Public Utility District (Chelan PUD) using neural networks. As variable renewable generation expands, hydropower units must operate with optimal efficiency and stability. For Kaplan machines, this flexibility is achieved through coordinated control of guide vane (wicket gates) opening and runner blade pitch, which amplifies the plant’s inherent nonlinear behavior and challenges traditional physics-only modeling. The efficiency of the Kaplan turbine varies with different combinations of the guide vans (wicket gate) opening and the blade angle. Each guide van opening and blade angle has a corresponding highest efficiency point, forming a cam relationship that represents the optimal combination.The discharge of a hydraulic turbine is controlled by the opening angle of the guide vans. Therefore, for each value of head, there is a certain guide van opening and blade angle that corresponds to the highest efficiency. For a given head, different combinations of the guide van opening and blade angle have different efficiencies. Therefore, coordinate cam curves are used to describe the relationship between the wicket gate opening and blade angle with different water head. To address these challenges, the manual details a data-driven modeling and learning workflow centered on structured neural networks. The approach is designed to forecast critical operational variables—discharge flow, net head, penstock (or scroll-case) pressure, and generator electrical outputs—by leveraging real-time inputs such as the generator power control setpoint, exciter field current and field voltage, together with hydromechanical commands (e.g., gate position and, when available, runner blade-pitch angle). The neural models are trained and validated on operational data from a Kaplan unit operated by Chelan PUD, demonstrating that the structured NN architecture can learn the coupled gate–blade–electrical dynamics. The result is a robust DT that improves situational awareness and supports data-informed decision-making for Chelan PUD’s Kaplan turbine operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Diaphragm Pump With Resonant Piezoelectric Drive

A diaphragm pump driven by a piezoelectric actuator is undergoing development. This pump is intended to be a prototype of lightweight, highly reliable pumps for circulating cooling liquids in protective garments and high-power electronic circuits, and perhaps for some medical applications. The pump would be highly reliable because it would contain no sliding seals or bearings that could wear, the only parts subject to wear would be two check valves, and the diaphragm and other flexing parts could be designed, by use of proven methods, for extremely long life. Because the pump would be capable of a large volumetric flow rate and would have only a small dead volume, its operation would not be disrupted by ingestion of gas, and it could be started reliably under all conditions. The prior art includes a number piezoelectrically actuated diaphragm pumps. Because of the smallness of the motions of piezoelectric actuators (typical maximum strains only about 0.001), the volumetric flow rates of those pumps are much too small for typical cooling applications. In the pump now undergoing development, mechanical resonance would be utilized to amplify the motion generated by the piezoelectric actuator and thereby multiply the volumetric flow rate. The prime mover in this pump would be a stack of piezoelectric ceramic actuators, one end of which would be connected to a spring that would be part of a spring-and-mass resonator structure. The mass part of the resonator structure would include the pump diaphragm (see Figure 1). Contraction of the spring would draw the diaphragm to the left, causing the volume of the fluid chamber to increase and thereby causing fluid to flow into the chamber. Subsequent expansion of the spring would push the diaphragm to the right, causing the volume of the fluid chamber to decrease, and thereby expelling fluid from the chamber. The fluid would enter and leave the chamber through check valves. The piezoelectric stack would be driven electrically to make it oscillate at the resonance frequency of the spring and- mass structure. This frequency could be made high enough (of the order of 400 Hz) that the masses of all components could be made conveniently small. The resonance would amplify the relatively small motion of the piezoelectric stack (a stroke of the order of 10 m) to a diaphragm stroke of the order of 0.5 mm. The exact amplification factor would depend on the rate of damping of oscillations; this, in turn, would depend on details of design and operation, including (but not limited to) the desired pressure rise and volumetric flow rate. In order to obtain resonance with large displacement, the damping rate must be low enough that the energy imparted to the pumped fluid on each stroke is much less than the kinetic and potential energy exchanged between the mass and spring during each cycle of oscillation. To minimize the power demand of the pump, a highly efficient drive circuit would be used to excite the piezoelectric stack. This circuit (see Figure 2) would amount to a special-purpose regenerative, switching power supply that would operate in a power-source mode during the part of an oscillation cycle when the excitation waveform was positive and in a power-recovery mode during the part of the cycle when the excitation waveform was negative. The circuit would include a voltage-boosting dc-to-dc converter that would convert between a supply potential of 24 Vdc and the high voltage needed to drive the piezoelectric stack. Because of the power-recovery feature, the circuit would consume little power. It should be possible to build the circuit as a compact unit, using readily available components.

Izenson, Michael G.↗

Graphene Electric Field Sensor Enables Single Shot Label-Free Imaging of Bioelectric Potentials

The measurement of electrical activity across systems of excitable cells underlies current progress in neuroscience, cardiac pharmacology, and neurotechnology. However, bioelectricity spans orders of magnitude in intensity, space, and time, posing substantial technological challenges. The development of methods permitting network-scale recordings with high spatial resolution remains key to studies of electrogenic cells, emergent networks, and bioelectric computation. Here, for this work, we demonstrate single-shot and label-free imaging of extracellular potentials with high resolution across a wide field-of-view. The critically coupled waveguide-amplified graphene electric field (CAGE) sensor leverages the field-sensitive optical transitions in graphene to convert electric potentials into the optical regime. As a proof-of-concept, we use the CAGE sensor to detect native electrical activity from cardiac action potentials with tens-of-microns resolution, simultaneously map the propagation of these potentials at tissue-scale, and monitor their modification by pharmacological agents. This platform is robust, scalable, and compatible with existing microscopy techniques for multimodal correlative imaging.

47 OTHER INSTRUMENTATION↗

High-resolution radiation detection using Ni/SiO 2 /n-4H-SiC vertical metal-oxide-semiconductor capacitor

In this article, we demonstrate the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on 20 μm thick n-4H-SiC epitaxial layers with the highest energy resolution ever reported. The 100 nm SiO2 layer was achieved on the Si face of n-4H-SiC epilayers using dry oxidation in air. The Ni/SiO2/n-4H-SiC MOS detectors not only demonstrated an excellent energy resolution of 0.42% (ΔE/E 100) for 5.48 MeV alpha particles but also caused a lower enhancement in the electronic noise components of the spectrometer compared with that observed for the best high-resolution Schottky barrier detectors. The MOS detectors also exhibited a high charge collection efficiency (CCE) of 96% at the optimized operating bias despite the presence of the oxide layer. A drift-diffusion model applied to the CCE vs gate bias voltage data revealed a minority (hole) carrier diffusion length of 24 μm. Capacitance mode deep level transient spectroscopy (C-DLTS) scans in the temperature range 84–800 K were carried out to identify the resolution limiting electrically active defects. Interestingly, the C-DLTS spectra revealed both positive and negative peaks, indicating the simultaneous presence of electron (majority) and hole (minority) trap centers. It has been inferred that at the steady-state bias for the C-DLTS measurement, the MOS detector operates in the inversion mode at certain device temperatures, causing holes to populate the minority trap centers and, hence, manifests minority carrier peaks as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Response Variability in Commercial MOSFET SEE Qualification

Single-event effects (SEE) evaluation of five different part types of next generation, commercial trench MOSFETs indicates large part-to-part variation in determining a safe operating area (SOA) for drain-source voltage (V DS ) following a test campaign that exposed >50 samples per part type to heavy ions. These results suggest a determination of a SOA using small sample sizes may fail to capture the full extent of the part-to-part variability. An example method is discussed for establishing a Safe Operating Area using a one-sided statistical tolerance limit based on the number of test samples. Finally, burn-in is shown to be a critical factor in reducing part-to-part variation in part response. Implications for radiation qualification requirements are also explored.

43 PARTICLE ACCELERATORS↗

Competition between modes with different axial structures in gyrotrons

This study was motivated by some experiments in which it was found that during the voltage rise, instead of expected excitation of a high-frequency parasitic mode, the excitation of a lower-frequency parasitic mode takes place in a certain range of voltages. For explaining this fact, the dependence of start currents of possible competing modes on the beam voltage was carried out in the cold-cavity approximation and by using the self-consistent approach. It was found that in the case of cavities, which consist of the combination of a section of constant radius waveguide and a slightly uptapered waveguide, these two approaches yield completely different results. Thus, experimentally observed excitation of the low-frequency parasitic mode can be explained by the self-consistent modification of the axial profile of the excited field, which has strong influence on the diffractive quality factor of competing modes. This modification is especially pronounced in the case of excitation of modes with many axial variations which can be excited in the region of beam interaction with the backward-wave component of such modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

IXO-XMS LVSID Anti-Coincidence Detector

This document describes a high-TRL backup implementation of the anti-coincidence detector for the IXO/XMS instrument. The backup detector, hereafter referred to as the low-voltage silicon ionization detector (LVSID), has been successfully flown on Astro-E2 (Suzaku)/XRS and is currently being implemented, without significant changes, on the Astro-H/SXS instrument. The LVSID anti-coincidence detector on Astro-E2/XRS operated successfully for almost 2 years, and was not affected by the loss of liquid helium in that instrument. The LVSID continues to operate after almost 5 years on-orbit (LEO, 550 km) but with slightly increased noise following the expected depletion of solid Neon after 22 months. The noise of the device is increased after the loss of sNe due to thermally induced bias and readout noise. No radiation damage, or off-nominal affects have been observed with the LVSID on-orbit during the Astro-E2/XRS program. A detector die from the same fabrication run will be used on the Astro-H/SXS mission. The LVSID technology and cryogenic JFET readout system is thus TRL 9. The technology is described in detail in section 2. The IXO/XMS "backup-up" anti-coincidence detector is a small array of LVSID detectors that are almost identical to those employed for Astro -E2/XRS as described in this document. The readout system is identical and, infact would use the same design as the Astro -E2/XRS JFET amplifier module (19 channels) essentially without changes except for its mechanical mount. The changes required for the IXO/XMS LVSID array are limited to the mounting of the LVSID detectors, and the mechanical mounting of the JFET amplifier sub-assembly. There is no technical development needed for the IXO/XMS implementation and the technology is ready for detailed design-work leading to PDR. The TRL level is thus at least 6, and possibly higher. Characteristics of an IXO/XMS LVSID anti-co detector are given in Table 1 and described in detail in section 3.

Porter, Scott F.↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The MIDNA application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Here, sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

1/f noise↗

The Direct Digital Modulation of Traveling Wave Tubes

Traveling wave tube (TWT) technology, first described by Rudolf Kompfner in the early 1940s, has been a key component of space missions from the earliest communication satellites in the 1960s to the Cassini probe today. TWTs are essentially signal amplifiers that have the special capability of operating at microwave frequencies. The microwave frequency range, which spans from approximately 500 MHz to 300 GHz, is shared by many technologies including cellular phones, satellite television, space communication, and radar. TWT devices are superior in reliability, weight, and efficiency to solid-state amplifiers at the high power and frequency levels required for most space missions. TWTs have three main components -an electron gun, slow wave structure, and collector. The electron gun generates an electron beam that moves along the length of the tube axis, inside of the slow wave circuit. At the same time, the inputted signal is slowed by its travel through the coils of the helical slow wave circuit. The interaction of the electron beam and this slowed signal produces a transfer of kinetic energy to the signal, and in turn, amplification. At the end of its travel, the spent electron beam moves into the collector where its remaining energy is dissipated as heat or harnessed for reuse. TWTs can easily produce gains in the tens of decibels, numbers that are suitable for space missions. To date, however, TWTs have typically operated at fixed levels of gain. This gain is determined by various, unchanging, physical factors of the tube. Traditionally, to achieve varying gain, an input signal s amplitude has had to first be modulated by a separate device before being fed into the TWT. This is not always desirable, as significant distortion can occur in certain situations. My mentor, Mr. Dale Force, has proposed an innovative solution to this problem called direct digital modulation . The testing and implementation of this solution is the focus of my summer internship. The direct digital modulation of a TWT removes the need for a separate amplitude modulation device. Instead, different levels of gain are achieved by varying the electron beam current. The lower the current, the less kinetic energy is available to be transferred to the signal. To vary the current, a grid is placed in-between the electron gun and the slow wave circuit. By changing the voltage across the grid, the electron beam current can be controlled. Grid technology has mostly been used in pulse applications such as radar, where only two voltage states are necessary. For direct digital modulation, however, a continuous range of voltages is required.

Radhamohan, Ranjan S.↗

Eigenmode analysis of the ITER ICRF antenna plug and electrical solution to the grounding of the antenna

The excitation of resonant modes in the gap between the ITER ICRH antenna plug and the vessel can considerably increase the level of RF currents and voltages on the ITER plug and disturb the radiation characteristic of the array. We report on a study of these modes and a solution to avoid them in the ITER ion cyclotron range of frequencies. From a transmission line approach we show that resonances can be avoided if the distance between the mouth of the line and an added short-circuit is sufficiently small. We therefore propose to position short-circuits at about lm from the antenna mouth, constituted by rows of closely spaced contacts all around the plug. These conclusions are further validated with Microwave Studio simulations. A simplified model of the ITER ICRF array is used for comparing various grounding solutions and it is proved that the solution already inferred from transmission line approximation suppresses the resonances from the frequency domain relevant for ICRH in ITER. The MWS calculations predict that the proposed solution also avoids large RF currents in the blanket modules and in their connectors. Their amplitude barely exceeds 5% of the strap RF currents. This solution avoids perturbation of the antenna array impedance matrix by the coaxial gap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗