Microphonics Studies at STC in Fermilab

The spoke test cryostat is used to qualify the 325 MHz single spoke resonators at Fermilab (FNAL). During these tests a large detuning on the cavity was observed. The data acquisition for continuous captures were based on measurements from the piezoelectric actuators. A com-parison of the cavity vibrations measured with RF signal from the cavity and piezoelectric actuator signals are shown. The effects of microphonics on the cavity are discussed.

43 PARTICLE ACCELERATORS↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

IDENTIFICATION OF POTENTIAL SUPERCONDUCTOR QUENCH PRECURSORS USING FREQUENCY DOMAIN FEATURE ANALYSIS

Superconducting magnets are important pieces of technology in the world of particle accelerators, allowing researchers to study atomic and subatomic phenomena, among other things. In some instances, superconductors can lose this non-resistive property in a phenomenon known as quenching, which can cause damage to the magnets. This potential danger prompts the introduction of systems to predict when a quench is imminent; one such implementation is through the use of acoustic sensors that detect vibrations within the magnet. Within these acoustic sensor signals, significantly above-noise disturbances (referred to as ”events”) can be identified. Our research applies the statistical framework of a permutation test to features calculated from the power spectral density (PSD) to distinguish between events far from the quench at the end of the signal to events at the start of the signal. We found that dividing the PSD into frequency bands produced a feature capable of distinguishing between events early in the signal and late in the signal leading up the quench, providing a promising starting place for future quench prediction systems.

Roehrig, Benjamin [Northern Illinois U.]↗

Status Report: Design and Fabricate Installation-Ready Test Capsule for the In-Situ Measurement of Elastic Properties Using an Optical Fiber-Based Measurement Technique

Microstructure evolution due to irradiation in a nuclear reactor can have a dramatic effect on material properties. A better understanding of this evolution is necessary for developing improved nuclear fuels and materials. The ability to measure such changes in real time is extremely limited due to the harsh conditions, high radiation fields, and limited access of the reactor environment. Through carefully designed experiments, measurement of elastic properties can be tied directly to microstructure. We present the methodology, design, and deployment plan for an instrument that has been developed to monitor grain microstructural changes during irradiation. Our measurement approach involves exciting and measuring the resonant frequency of a thin cantilever beam. Excitation and detection of the flexural vibrations of the beam are accomplished using optical methods that require only an optical fiber connection between the instrumentation and the sample. This technique has been demonstrated in a laboratory setting to monitor the recrystallization of highly textured copper during high temperature annealing. A test capsule incorporating this technique has been developed for in reactor testing. The capsule has been designed to be compatible with a reusable test module that allows simplified insertion in the TREAT reactor at INL. An exact replica of the instrument described in this Status Report, constructed from Quality Level 3 materials, is slated to be inserted into the TREAT reactor in FY19.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Vibration of a cryomodule’s coupler during road transportation: Multibody analysis and experimental validation

The road transportation of critical components for cryogenic cryomodules is a challenging task. Indeed, the shipping and the handling of fundamental sub-assemblies can expose these components to harmful dynamic loads that can jeopardize their structural integrity. This article has the purpose of developing a finite element multibody model capable of assessing the acceleration on a test coupler for a cavity of the Single Spoke Resonator 1 subjected to a typical road transportation trip. A multibody model consisting of rigid bodies and finite element–imported flexible bodies has been created allowing a comparison of the simulated and experimental acceleration. Afterwards, an experimental on-road test, whose set-up is described in this article, has been carried out at Fermilab with instrumented components. Being able to effectively simulate and validate the dynamic effects on such sub-assemblies makes it possible, for the future, to simulate more complex structures subject to dynamic loadings, such as the entire cryomodules during shipping. Furthermore, the results from the simulations can be used to guide the design of new suspension systems suitable for the reduction mitigation of structural vibration during the road transportation of cryomodules.

42 ENGINEERING↗

Hydrodynamic and Structural Response Modeling of a Prototype Floating Membrane Reservoir System for Pumped Storage Hydropower

Hydrodynamic, computational fluid dynamics, and finite-element modeling were performed for a novel floating membrane reservoir system design for closed-loop pumped storage hydropower application. The conceptual design, which is now protected under an invention disclosure with a patent pending, offers a potential low-cost, low-impact solution to address the high costs, long investment return periods, and environmental disruptions encountered with traditional pumped storage development while offering modularity to enable replication at many locations. Prior to physical tests on a prototype, this paper documents the response analysis and modeling completed to simulate hydraulic and structural performance under different reservoir deployment and alignment arrangements, evaluate system stability, and refine the conceptual design. The results indicate that the excitation frequency from vortex shedding is at least an order of magnitude lower than the water sloshing frequencies in the reservoir, the structural natural frequency of the entire reservoir, and the vibrational frequencies of the side membranes, although excitation frequencies from other sources could cause mechanical resonance under certain conditions. To control destabilizing effects and prevent rocking motion and vibration, the authors conclude that the design could be improved by including a support structure around the floating reservoir, which could also provide floating-membrane containment, improve safety, and facilitate vertical reservoir movement. These conclusions, based on hydrodynamic and structural response modeling, help define specifications for upcoming full-scale prototype construction, deployment, and testing. This study demonstrates standard modeling technique application to an innovative design for which similar applications have not been previously evaluated. As a result, the refined design is capable of improving the scalability and feasibility of pumped storage hydropower in the United States and will be considered for commercialization following prototype testing.

13 HYDRO ENERGY↗

Mechanical design and vibro-acoustic testing of ultrathin carbon foils for a spacecraft instrument

IBEX-Hi is an electrostatic analyzer spacecraft instrument designed to measure the energy and flux distribution of energetic neutral atoms (ENAs) emanating from the interaction zone between the Earth's solar system and the Milky Way galaxy. A key element to this electro-optic instrument is an array of fourteen carbon foils that are used to ionize the ENAs. The foils are comprised of an ultrathin (50-100 {angstrom} thick) layer of carbon suspended across the surface of an electroformed Nickel wire screen, which in turn is held taught by a metal frame holder. The electro formed orthogonal screen has square wire elements, 12.7 {micro}m thick, with a pitch of 131.1 wires/cm. Each foil holder has an open aperture approximately 5 cm by 2.5 cm. Designing and implementing foil holders with such a large surface area has not been attempted for spaceflight in the past and has proven to be extremely challenging. The delicate carbon foils are subject to fatigue failure from the large acoustic and vibration loads that they will be exposed to during launch of the spacecraft. This paper describes the evolution of the foil holder design from previous space instrument applications to a flight-like IBEX-Hi prototype. Vibro-acoustic qualification tests of the IBEX-Hi prototype instrument and the resulting failure of several foils are summarized. This is followed by a discussion of iterative foil holder design modifications and laser vibrometer modal testing to support future fatigue failure analyses, along with additional acoustic testing of the IBEX-Hi prototype instrument. The results of these design and testing activities are merged and the resulting flight-like foil holder assembly is proposed.

47 OTHER INSTRUMENTATION↗

Influence of neutron irradiation on Al-6061 alloy produced via ultrasonic additive manufacturing

Samples of aluminum alloy 6061 produced via ultrasonic additive manufacturing (UAM) were irradiated in the High Flux Isotope Reactor (HFIR) up to 17.3 dpa at ~70°C while in contact with water using perforated rabbit capsules. The irradiation campaign included as-received (AR) material, specimens subjected to various post-weld heat treatments (PWHTs, including hot isostatic pressing [HIP]), and reference (wrought) alloy samples. Mechanical tensile tests, accompanied by digital image correlation (DIC) analysis, fractography, and metallography, were performed as a part of the post-irradiation evaluation. The X- and Y-specimens (i.e., oriented in the sonotrode moving and vibration directions, respectively) showed pronounced radiation hardening and ductility decrease. Specific serration flow behavior and propagation of deformation bands were observed under various material conditions up to 3.5 dpa but disappeared at 17.3 dpa. In all cases, the fracture mechanism of X- and Y-specimens was ductile; ductile dimples dominated the fracture surface. Irradiated X- and Y-specimens showed good performance, regardless of material conditions (AR or PWHT). The performance of Z-specimens oriented in the build direction was strongly dependent on the PWHT. The AR and aged specimens showed fracture stress decrease with dose, and they experienced fracture under irradiation after 3.5 dpa; specimen cross section analysis revealed specific interface degradation that was likely related to corrosion. Recrystallization significantly improved in-reactor performance. Finally, HIP suppressed interface degradation due to recrystallization and pore removal, which led to good in-reactor performance for Z-specimens.

36 MATERIALS SCIENCE↗

Competitive Adsorption of Lubricant Base Oil and Ionic Liquid Additives at Air/Liquid and Solid/Liquid Interfaces

Oil-soluble ionic liquids (ILs) have been proved as effective additives in lubricant oils through tribological experiments and post-test analytical analyses. Here, surface structures of lubricant base oil, oil-soluble ILs, and their mixtures at the air/liquid and solid/liquid interfaces have been studied using sum frequency generation (SFG) vibrational spectroscopy. At the air/base oil and air/IL interfaces, the alkyl chains of the studied compounds were shown to be conformationally disordered and their terminal methyl groups point outward at the liquid surface. The base oil dominates the air/(base oil + IL) interface due to its higher surface excess propensity and larger bulk concentration. At the solid (silica) surface, ILs adopt a structure with their charged headgroups in contact with the silica surface, while their alkyl chains are more conformationally ordered or packed compared to the air/IL interface. At the interface between silica and (base oil + IL) mixtures, ILs also preferentially adsorb to the silica surface with their layer structures somewhat different from those of ILs alone. These results showed that ILs can adsorb onto the solid surface even before tribological contacts are made. The insights obtained from this SFG study provide a better understanding of the role of ionic liquids in lubrication.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vibronic-structure tracking: A shortcut for vibrationally resolved UV/Vis-spectra calculations

The vibrational coarse structure and the band shapes of electronic absorption spectra are often dominated by just a few molecular vibrations. By contrast, the simulation of the vibronic structure even in the simplest theoretical models usually requires the calculation of the entire set of normal modes of vibration. Here, we exploit the idea of the mode-tracking protocol [M. Reiher and J. Neugebauer, J. Chem. Phys. 118, 1634 (2003)] in order to directly target and selectively calculate those normal modes which have the largest effect on the vibronic band shape for a certain electronic excitation. This is achieved by defining a criterion for the importance of a normal mode to the vibrational progressions in the absorption band within the so-called “independent mode, displaced harmonic oscillator” (IMDHO) model. We use this approach for a vibronic-structure investigation for several small test molecules as well as for a comparison of the vibronic absorption spectra of a truncated chlorophyll a model and the full chlorophyll a molecule. We show that the method allows to go beyond the often-used strategy to simulate absorption spectra based on broadened vertical excitation peaks with just a minimum of computational effort, which in case of chlorophyll a corresponds to about 10% of the cost for a full simulation within the IMDHO approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving the precision of forces in real-space pseudopotential density functional theory

The high-order finite difference real-space pseudopotential density functional theory (DFT) approach is a valuable method for large-scale, massively parallel DFT calculations. A significant challenge in the approach is the oscillating “egg-box” error introduced by aliasing associated with a coarse grid spacing. To address this issue while minimizing computational cost, we developed a finite difference interpolation (FDI) scheme [Roller et al., J. Chem. Theory Comput. 19, 3889 (2023)] as a means of exploiting the high resolution of the pseudopotential to reduce egg-box effects systematically. Here, we show an implementation of this method in the PARSEC code and examine the practical utility of the combination of FDI with additional methods for improving force precision and/or reducing its computational cost, including orbital-based forces, compensating charges (namely, adding and subtracting a judiciously chosen charge density such that the total density is unaltered), and a modified spatial domain in which the real-space grid is defined. Using selected small molecules, as well as metallic Li, as test cases, we show that a combination of all four aspects leads to a significant reduction in computational cost while retaining a high level of precision that supports accurate structures and vibrational spectra, as well as stable and accurate molecular dynamics runs.

Chemistry↗

Application of accelerometers for sensing combustion phasing of an advanced combustion engine

This paper evaluates the ability of accelerometers to detect combustion phasing of a single-cylinder air-cooled internal combustion engine undergoing homogeneous charge compression ignition. Metrics derived from the measured surface acceleration waveform, surface velocity, and the surface-specific kinetic energy were compared to the 50 per cent energy release location (CA50) on a cyclic basis for three different experimental test cases. The peak surface velocity location showed a robust ability to detect CA50 on a cyclic basis for short combustion durations. Finally, using a simple single-degree-of-freedom vibration model, it is shown the impulsive nature of the combustion load and the natural frequency of the engine structure governs when the peak velocity location will indeed robustly detect CA50 on a on a per-engine cycle basis.

33 ADVANCED PROPULSION SYSTEMS↗

Design of a Transport System for the PIP-II HB650 Cryomodule

The PIP-II Project at FNAL requires the assembly of 3 high-beta 650MHz cryomodules at STFC Daresbury (DL) in the UK. These modules must be safely transported from DL to FNAL in the USA. Previous experience with cryomodule transport was leveraged at both labs to design a transport system to protect the cryomodules during transit. Requirements for the system included mitigation of shocks, drops, and vibrations, and acting as a lifting fixture. It is comprised of a tessellated steel frame which encompasses the module with a wire rope isolator arrangement which the module mounts to. The frame was designed to withstand the weight of the 12.5 tonne cryomodule in various load cases. Details of shock and vibration profiles were obtained from MIL-STD-810H and were used to guide the sizing of the isolators. The frame and the isolation system were analysed via FEA using the shock and vibration profiles as an input. The transport system was found to be suitable for the given isolation, frame stiffness, and lifting code requirements. The frame has been fabricated and successfully load tested at FNAL. It will now be road tested with a dummy cryomodule before undergoing a trial run to DL.

43 PARTICLE ACCELERATORS↗

ORNL Interim Progress Report on Static CIRFT Testing Curvature Data Update

Since the CIRFT tests reported in NUREG-7198 were generated, a number of factors that influence the recorded curvature measurement data were identified. In 2016, a data reanalysis task was undertaken to implement the lessons learned. This letter report provides the revised results of previous CIRFT tests, after implementing the following data reanalysis procedures: (A) experimental data smoothing and LVDT reset, (B) LVDT probe contact and sensor spacing correction for curvature data, and (C) LVDT probe dynamic vibration adjustment procedure development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extreme Radiation Hardness and Space Qualification of AlGaN Optoelectronic Devices

Unprecedented radiation hardness and environment robustness are required in the new generation of high energy density physics (HEDP) experiments and deep space exploration. National Ignition Facility (NIF) break-even shots will have a neutron yield of 1015 or higher. The Europa Jupiter System Mission (EJSM) mission instruments will be irradiated with a total fluence of 1012 protons/cm2 during the space journey. In addition, large temperature variations and mechanical shocks are expected in these applications under extreme conditions. Hefty radiation and thermal shields are required for Si and GaAs based electronics and optoelectronics devices. However, for direct illumination and imaging applications, shielding is not a viable option. It is an urgent task to search for new semiconductor technologies and to develop radiation hard and environmentally robust optoelectronic devices. We will report on our latest systematic experimental studies on radiation hardness and space qualifications of AlGaN optoelectronic devices: Deep UV Light Emitting Diodes (DUV LEDs) and solarblind UV Photodiodes (PDs). For custom designed AlGaN DUV LEDs with a central emission wavelength of 255 nm, we have demonstrated its extreme radiation hardness up to 2x1012 protons/cm2 with 63.9 MeV proton beams. We have demonstrated an operation lifetime of over 26,000 hours in a nitrogen rich environment, and 23,000 hours of operation in vacuum without significant power drop and spectral shift. The DUV LEDs with multiple packaging styles have passed stringent space qualifications with 14 g random vibrations, and 21 cycles of 100K temperature cycles. The driving voltage, current, emission spectra and optical power (V-I-P) operation characteristics exhibited no significant changes after the space environmental tests. The DUV LEDs will be used for photoelectric charge management in space flights. For custom designed AlGaN UV photodiodes with a central response wavelength of 255 nm, we have demonstrated its extreme radiation hardness using a 65 MeV proton beam line. The solar-blind AlGaN photodiodes retained ~50% responsivity up to 3x1012 protons/cm2 fluence. The Stanford-NSTec-SETI team will continue to develop radiation hard optoelectronic devices for applications under extreme conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Missile Captive Carry Monitoring and Helicopter Identification Using a Capacitive Microelectromechanical Systems Accelerometer

Military missiles are exposed to many sources of mechanical vibration that can affect system reliability, safety, and mission effectiveness. The U. S. Army Aviation and Missile Research Development and Engineering Center (AMRDEC) has been developing missile health monitoring systems to assess and improve reliability, reduce life cycle costs, and increase system readiness. One of the most significant exposures to vibration occurs when the missile is being carried by a helicopter or other aviation platform, which is a condition known as captive carry. Recording the duration of captive carry exposure during the missile’s service life can enable the implementation of predictive maintenance and resource management programs. Since the vibration imparted by each class of helicopter varies in frequency and amplitude, tracking the vibration exposure from each helicopter separately can help quantify the severity and harmonic content of the exposure. Under the direction of AMRDEC staff, engineers at the Pacific Northwest National Laboratory have developed a Captive Carry Health Monitor (CCHM) for the Hellfire II missile. The CCHM is an embedded usage monitoring device installed on the outer skin of the Hellfire II missile to record the cumulative hours the host missile has been in captive carry mode. To classify the vibration by class of helicopter, the CCHM analyzes the amplitude and frequency content of the vibration with the Goertzel algorithm to detect the presence of distinctive rotor harmonics. Cumulative usage data are accessible in theater from an external display; monthly usage histograms are accessible through an internal download connector. This paper provides an overview of the CCHM electrical and package design, describes field testing and data analysis techniques used to monitor captive carry identify and the class of helicopter, and discusses the potential application of missile health and usage data for real-time reliability analysis and fleet management.

Goertzel, HUMS↗

Hypersharp Resonant Capture of Neutrinos as a Laboratory Probe of the Planck Length

The 18.6 keV antineutrino ({nu}-tilde{sub e}) line from the two-body decay of {sup 3}H in crystals can be emitted with a natural width because of motional averaging by lattice vibrations despite the very long lifetime of {sup 3}H and contrary to commonly held views of linewidths in such a case. It can be resonantly captured in {sup 3}He with geometrical cross section {sigma}{approx}10{sup -17} cm{sup 2}. Using its hypersharp sensitivity {delta}E/E{approx}10{sup -29} and the method of 'time-filtered' resonance, the basic energy width {approx}10{sup -24} eV expected of the {sup 3}H state can be measured to test if ultimate nuclear widths are limited by the Planck length rather than time-energy uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress Report on Reverse Bending Fatigue Testing of Zry-4 Surrogate Rod

Testing high-burnup spent nuclear fuel (SNF) presents many challenges in areas such as specimen preparation, specimen installation, mechanical loading, load control, measurements, data acquisition, and specimen disposal because these tasks are complicated by the radioactivity of the test specimens. Unique features of the test and testing specimens demand that the test plan address these issues from the very beginning.

Fuel Transportation↗