SEARCH · Search NASA
Results for “Water Recovery”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Detritiation and Recovery of Heavy Water Moderator for Commercial Use
Historical Inventory Savannah River Site hosted five tritium production reactors from the 1950s through 1990s • Pressurized heavy water reactor • D2O moderator • Approximately 1900 m3 of legacy moderator water is in storage • Ranges from 1% D2O to 99.8% D2O • Varying amounts of tritium, relatively low amounts of other radioactive elements • Due to shortage in D2O production, US Department of Energy is investigating detritiating the heavy water for commercial uses
A feasibility study for the recovery of potable water from body wastes Final report
Explore the source record for details and available documents.
Recovery of potable water from human wastes in below-G conditions Patent
Potable water reclamation from human wastes in zero-G environment
Recovery of atmospheric water vapor total column abundance from imaging spectrometer data around 940 nm - Sensitivity analysis and application to Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data
Two simple techniques (Continuum Interpolated Band Ratio, CIBR, and Narrow/Wide ratio, N/W) to retrieve path precipitable water from AVIRIS high spectral resolution radiance data using the 940 nm water absorption band are compared. A sensitivity analysis was performed using the radiative transfer code LOWTRAN 7 to determine which one of these two approaches will provide a better estimate over land and water areas. The CIBR proved to be the technique less sensitive to perturbing effects, except for errors in visibility estimate. Both techniques were applied to AVIRIS radiance data acquired over Salton Sea, California. Resulting images confirmed that the use of a constant gray reflectance in the model led to a higher overestimation of the amount of water retrieved for N/W over vegetated areas. Validation was performed through comparison between an independent estimate of water vapor from concurrent Reagan sunphotometer measurements and AVIRIS estimates. Amounts retrieved using the N/W approach match more closely in situ measurements, even after adjusting model parameters for background reflectance, viewing geometry, and type of aerosol at the site.
Recovery of Atmospheric Water Vapor Total Column Abundance from Imaging Spectrometer Data Around 940 nm - Sensitivity Analysis and Application to Airborne Visible/Infrared Imaging Spectrometer (AVIRI
Twosimple techniques to retrieve path precipitable water fromthe Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) high spectral resolution radiance data (Continuum Interpolated Band Ratio, CIBR, and Narrow/Wide Ratio, N/W), using the 940 nm water absorption band, are compared.
Supporting the Deep Water Horizon Accident Recovery Efforts: Experiences and Learnings.
Abstract not provided.
Low-Cost Environment-Friendly Critical Materials Recovery from Produced Water, US DOE SBIR Phase I Final Report, DOE_DE-SC0022939_I_Final_OSTI
Explore the source record for details and available documents.
Effect of Rotary Evaporator Water Bath Temperature on Recovery Rate of Phthalate Esters
To clarify the influence of water bath temperature on the decompression and concentration efficiency of a rotary evaporator, accurate control of the water bath temperature is required. Therefore, the water bath temperature control system of a rotary evaporator was studied using the recovery rate of phthalate esters (PAEs) as the indicator. The results showed that when the temperature of the rotary evaporator was set at 40°C, the actual temperature range of the concentrated liquid would change from 26–41 to 39–41°C. By modifying the water bath temperature control system, the recovery rate of PAEs could be increased from 72.4% to 85.6% to 93.2%–98.5%. This test indicates that temperature has a great influence on vacuum concentration, and the recovery rate of PAEs can be improved by modifying the water bath temperature control system used in the rotary evaporator.
Hydrogen isotope recovery using a cathode water vapor feed PEM electrolyzer
A critical component of tritium glovebox operations is the recovery of high value tritium from the water vapor in the glove box atmosphere. One proposed method to improve existing tritium recovery systems is to replace the disposable hot magnesium beds used to separate the hydrogen and oxygen in water with continuous use Proton Exchange Membrane Electrolyzers (PEMEs). This study examines radiation exposure to the membrane of a PEME and examines the sizing difference that would be needed if the electrolyzer were operated with a cathode water vapor feed instead of an anode liquid water feed. (authors)
Uranium Resource Recovery from Desalination Plant Feed and Reject Water Using Amidoxime Functionalized Adsorbent
With global demand for nuclear power expected to rise, new nuclear fuel resources must be explored to ensure the viability and sustainability of nuclear power. Uranium recovery from seawater is one potential source, though the low concentration of uranium in seawater is a significant obstacle. As a concentrate of seawater, desalination brine reject would have a significantly higher uranyl concentration. In this work, the adsorption of uranium and competing ions in brine reject is investigated. Adsorption experiments were performed over 84 days in 5-gallon batch tanks with amidoxime adsorbents and samples taken from the feed seawater and reverse osmosis brine reject of the Tampa Bay Desalination Plant. The aqueous concentration and adsorbed mass of uranium, zinc, copper, iron, vanadium, calcium, and magnesium were determined through inductively coupled plasma mass spectroscopy. Aqueous adsorption modeling was used to simulate speciation and adsorption of these ions under the experimental conditions. The adsorbed mass of uranium in seawater was 6.22 mg/g adsorbent which declined to 3.95 mg/g in brine. This is a result of increased competition from iron and vanadium whose adsorbed masses increased from 1.06 to 3.00 mg/g and 1.05 to 2.67 mg/g, respectively. Good agreement between experimental and predicted results was obtained for all ions in seawater. Uranium adsorption was overpredicted in brine which may be attributed to the presence of other competing ions and the system not being at equilibrium. Furthermore, results demonstrate that the influence of competing ions, such as those of iron and vanadium, on uranium adsorption would need to be reduced for brine reject to become a significant uranium resource.
Co-treating flue gas desulfurized effluent and produced water enables novel waste management and recovery of critical minerals
Herein this study reports a novel approach of resource recovery from co-managing two geographically co-located and chemically complementary wastewaters using a pilot-scale treatment process. Designed to treat flue gas desulfurized (FGD) effluent from combustion powerplants and produced water (PW) from energy industries, the process consists of soda-ash softening, nanofiltration (NF), and reverse osmosis (RO). Recovered products are barite, calcite, and low-salinity water. Using field-collected waters, the results show that softening at pH 8.5 produces calcite (yield: 30 kg/m 3 treated water), a chemical used as SO ₂(g) scrubbers. NF treatment under an applied pressure of 3.5 MPa yields a permeate stream laden with monovalent ions (water recovery 60%) and a concentrate stream with a sulfate concentration 1.8 times of the feedwater concentration. Mixing the NF concentrate and PW at a volumetric ratio of 1.0 precipitates a high-density barite material (4.1 g/cm 3 , yield: ~7.5 kg/m 3 mixture) – a critical mineral commonly used as a weighting agent in drilling. The RO treatment recovers >64% water as the permeate, which can be readily used as cooling make-up water at the powerplants. The RO concentrate stream can be further processed in a thermal evaporative system for additional water recovery and brine production.
Reuse of Produced Water from CO 2 Enhanced Oil Recovery, Coal-Bed Methane, and Mine Pool Water by Coal-Based Power Plants
Power generation in the Illinois Basin is expected to increase by as much as 30% by the year 2030, and this would increase the cooling water consumption in the region by approximately 40%. This project investigated the potential use of produced water from CO 2 enhanced oil recovery (CO 2 -EOR) operations; coal-bed methane (CBM) recovery; and active and abandoned underground coal mines for power plant cooling in the Illinois Basin. Specific objectives of this project were: (1) to characterize the quantity, quality, and geographic distribution of produced water in the Illinois Basin; (2) to evaluate treatment options so that produced water may be used beneficially at power plants; and (3) to perform a techno-economic analysis of the treatment and transportation of produced water to thermoelectric power plants in the Illinois Basin. Current produced water availability within the basin is not large, but potential flow rates up to 257 million liters per day (68 million gallons per day (MGD)) are possible if CO 2 -enhanced oil recovery and coal bed methane recovery are implemented on a large scale. Produced water samples taken during the project tend to have dissolved solids concentrations between 10 and 100 g/L, and water from coal beds tends to have lower TDS values than water from oil fields. Current pretreatment and desalination technologies including filtration, adsorption, reverse osmosis (RO), and distillation can be used to treat produced water to a high quality level, with estimated costs ranging from $2.6 to $10.5 per cubic meter ($10 to $40 per 1000 gallons). Because of the distances between produced water sources and power plants, transportation costs tend to be greater than treatment costs. An optimization algorithm was developed to determine the lowest cost pipe network connecting sources and sinks. Total water costs increased with flow rate up to 26 million liters per day (7 MGD), and the range was from $4 to $16 per cubic meter ($15 to $60 per 1000 gallons), with treatment costs accounting for 13-23% of the overall cost. Results from this project suggest that produced water is a potential large source of cooling water, but treatment and transportation costs for this water are large.
A Computational Framework for Evaluating and Optimizing Critical Mineral Recovery Opportunities in Produced Water Networks
In this presentation, we show a quadratically constrained optimization model to assess how operational decisions in a produced water network can meet minimum Lithium recovery concentration requirements while minimizing operating costs. We also discuss the need for global optimization algorithmic tools and how we look to address such challenges.
A Framework for Evaluating and Optimizing Critical Mineral Recovery Opportunities in Produced Water Networks
Demonstrate how to use project PARETO framework for screening different produced water networks and identify critical minerals recovery opportunities.
Evaluating ecosystem water use efficiency and recovery dynamics during flash droughts: insights from observations and model simulations
Flash droughts (FD), rapidly emerging in a warming future, disrupt ecosystems, agriculture, and water security. Ecosystem water use efficiency (WUE), the ratio of gross primary production (GPP) to actual evapotranspiration (AET), balances carbon assimilation and water loss. FD rapidly disrupts this balance, making WUE critical for assessing plant stress and recovery. Here, this study investigates the dynamics of landscape-scale WUE, and the components of GPP and AET under FD utilizing both observed data from the Missouri Ozark AmeriFlux site (US-MOz) and version 2 of the U.S. Department of Energy’s Earth, Energy, Exascale System Model (E3SM) Land Model (ELMv2). Observations and simulations reveal GPP as dominant for WUE during earlier FD events (2005, 2007, 2012), shifting to AET in recent events (2014, 2018). This agreement indicates that the ELM can capture the shifting dynamics of GPP and AET in regulating WUE under FD conditions. However, the ELM systematically underestimates both GPP and AET and does so in a manner that does not preserve their ratio. As a result, WUE is also underestimated, suggesting that GPP is more strongly underestimated than AET. Furthermore, the ELM also underestimates the speed of GPP recovery, producing an artificially prolonged GPP recovery time following FD events. Observed environmental drivers such as vapor pressure deficit (VPD), soil moisture (SM), and predawn leaf water potential (PLWP) effectively predict WUE, but ELM primarily highlights SM, underestimating VPD’s role. This study demonstrates that relying solely on soil moisture fails to capture the rapid hydraulic recovery observed in PLWP, underscoring the necessity of integrating plant hydraulics into land surface models to improve flash drought predictability.
Radiance-ratio algorithm wavelengths for remote oceanic chlorophyll determination
Two-band radiance-ratio in-water algorithms in the visible spectrum have been evaluated for remote oceanic chlorophyll determination. Airborne active-passive (laser-solar) data from coastal, shelf-slope, and blue-water regions were used to generate two-dimensional chlorophyll-fluorescence and radiance-ratio statistical correlation matrices containing all possible two-band ratio combinations from the thirty-two available contiguous 11.25-nm passive bands. The principal finding was that closely spaced radiance-ratio bands yield chlorophyll estimates which are highly correlated with laser-induced chlorophyll fluorescence within several distinct regions of the ocean color spectrum. Band combinations in the yellow, orange-red, spectral regions showed considerable promise for satisfactory chlorophyll pigment estimation in near-coastal Case II waters. Pigment recovery in Case I waters was best accomplished using blue-green radiance ratios in the 490/500-nm region.
Supercritical Water Oxidation and a Preliminary Concept for Lunar Application
Abstract: Water is a critical resource for crewed space exploration missions and reclamation of aqueous waste streams presents the only long-term viable option. Although early Artemis missions are considering water as part of the payload manifest, it would be extremely advantageous if follow-on missions were supplied—either in total or in part—by a reclamation technology that would operate autonomously between missions. An attractive technology is currently under ongoing research at NASA Glenn Research Center (GRC) that employs a Supercritical Water Oxidation (SCWO) process to destroy all hydrocarbons in the waste stream. Testing of an aqueous waste stream simulant, typical of what is generated on the International Space Station (ISS), has shown reductions in Total Organic Carbon (TOC) of greater than 99% with reactor residence times less than 30 s. Recent effort has been directed toward developing a conceptual design based on the current tubular reactor used in the evaluation of the conversion of SCWO. This conceptual design along with the results of recent SCWO conversion experiments will be presented. Recent design enhancements to achieve shorter residence times along with “production simulation” tests will be presented. The diagnostics used in assessing the extent of the waste conversion include a total organic carbon (TOC) analysis, Raman analyses, and measurements of pH, turbidity, and conductivity. Results obtained from the modified reactor configuration will also be compared to those of the Phase I configuration presented in earlier work.