Search NASA⌕ Search

SEARCH · Search NASA

Results for “accurate quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Targeted Quantification of Protein Phosphorylation and Its Contributions towards Mathematical Modeling of Signaling Pathways

Post-translational modifications (PTMs) are key regulatory mechanisms that can control protein function. Of these, phosphorylation is the most common and widely studied. Because of its importance in regulating cell signaling, precise and accurate measurements of protein phosphorylation across wide dynamic ranges are crucial to understanding how signaling pathways function. Although immunological assays are commonly used to detect phosphoproteins, their lack of sensitivity, specificity, and selectivity often make them unreliable for quantitative measurements of complex biological samples. Recent advances in Mass Spectrometry (MS)-based targeted proteomics have made it a more useful approach than immunoassays for studying the dynamics of protein phosphorylation. Selected reaction monitoring (SRM)—also known as multiple reaction monitoring (MRM)—and parallel reaction monitoring (PRM) can quantify relative and absolute abundances of protein phosphorylation in multiplexed fashions targeting specific pathways. In addition, the refinement of these tools by enrichment and fractionation strategies has improved measurement of phosphorylation of low-abundance proteins. The quantitative data generated are particularly useful for building and parameterizing mathematical models of complex phospho-signaling pathways. Potentially, these models can provide a framework for linking analytical measurements of clinical samples to better diagnosis and treatment of disease.

mathematical modeling↗

A Decision-Relevant Factor-Fixing Framework: Application to Uncertainty Analysis of a High-Dimensional Water Quality Model

Factor Fixing (FF) is a common method for reducing the number of model parameters to lower computational cost. FF typically starts with distinguishing the insensitive parameters from the sensitive and pursues uncertainty quantification (UQ) on the resulting reduced-order model, fixing each insensitive parameter at a fixed value. There is a need, however, to expand such a common approach to consider the effects of decision choices in the FF-UQ procedure on metrics of interest. Therefore, to guide the use of FF and increase confidence in the resulting dimension-reduced model, we propose a new adaptive framework consisting of four principles: (a) re-parameterize the model first to reduce obvious non-identifiable parameter combinations, (b) focus on decision relevance especially with respect to errors in quantities of interest (QoI), (c) conduct adaptive evaluation and robustness assessment of errors in the QoI across FF choices as sample size increases, and (d) reconsider whether fixing is warranted. The framework is demonstrated on a spatially-distributed water quality model. The error in estimates of QoI caused by FF can be estimated using a Polynomial Chaos Expansion (PCE) surrogate model. Built with 70 model runs, the surrogate is computationally inexpensive to evaluate and can provide global sensitivity indices for free. For the selected catchment, just two factors may provide an acceptably accurate estimate of model uncertainty in the average annual load of Total Suspended Solids (TSS), suggesting that reducing the uncertainty in these two parameters is a priority for future work before undertaking further formal uncertainty quantification.

54 ENVIRONMENTAL SCIENCES↗

Low background screening capability in the UK

Low background rare event searches in underground laboratories seeking observation of direct dark matter interactions or neutrino-less double beta decay have the potential to profoundly advance our understanding of the physical universe. Successful results from these experiments depend critically on construction from extremely radiologically clean materials and accurate knowledge of subsequent low levels of expected background. The experiments must conduct comprehensive screening campaigns to reduce radioactivity from detector components, and these measurements also inform detailed characterisation and quantification of background sources and their impact, necessary to assign statistical significance to any potential discovery. To provide requisite sensitivity for material screening and characterisation in the UK to support our rare event search activities, we have re-developed our infrastructure to add ultra-low background capability across a range of complementary techniques that collectively allow complete radioactivity measurements. Ultra-low background HPGe and BEGe detectors have been installed at the Boulby Underground Laboratory, itself undergoing substantial facility re-furbishment, to provide high sensitivity gamma spectroscopy in particular for measuring the uranium and thorium decay series products. Dedicated low-activity mass spectrometry instrumentation has been developed at UCL for part per trillion level contaminant identification to complement underground screening with direct U and Th measurements, and meet throughput demands. Finally, radon emanation screening at UCL measures radon background inaccessible to gamma or mass spectrometry techniques. With this new capability the UK is delivering half of the radioactivity screening for the LZ dark matter search experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Postmortem validation of breast density using dual-energy mammography

Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.

60 APPLIED LIFE SCIENCES↗

DEPRECATED AI-Batt-OS (Autonomous Identification of Battery Life Models - Open Source) [SWR 21-17]

DEPRECATED. This repository was archived by the owner on Jun 30, 2026. It is now read-only. Open source implementation of some of the methods utilized by AI-Batt, a battery lifetime modeling and analysis toolkit provided by the National Laboratory of the Rockies (NLR). This software demonstrates the use of bi-level optimization and symbolic regression techniques to semi-autonomously identify algebraic models predicting the capacity fade of lithium-ion batteries during calendar aging. Modeling the degradation of batteries is a complex task, due to the difficulty in separating the time-dependent and time-independent factors impacting cell level degradation, across multiple data series with different numbers of measurements and/or data quality. Bi-level optimization enables model parameters to be optimized to either the entire data set or to individual data series, allowing statistical disambiguation of global behaviors (data series independent) and local behaviors (data series dependent). Symbolic regression is used to automatically search for optimal low-dimesional models predicting the variation of locally optimized parameters versus time-independent experimental variables from millions of possible models, resulting in a more accurate and repeatable model identification process than is possible by a manual search. The provided tools also implement cross-validation and bootstrap resampling schemes, empowering statistical model comparison/selection and quantification of model uncertainties. An example script replicates the results from the manuscript "Challenging Practices of Algebraic Battery Life Models through Statistical Validation and Model Identification via Machine-Learning", submitted to ECS. All code is written in MATLAB. Requires the Statistics and Machine Learning Toolbox. Contact Dr. Paul Gasper at Paul.Gasper@nlr.gov for any questions.

Gasper, Paul↗

Machine Learning for Turbulence Modeling

This work was conducted as part of a Harry S. Truman Fellowship Laboratory Directed Research and Development project. The goal was to use machine learning methods to provide uncertainty quantification and model improvements for Reynolds Averaged Navier Stokes (RANS) turbulence models. For applications of interest in energy, safety, and security, it is critical to be able to model turbulence accurately. Current RANS models are unreliable for many flows of engineering relevance. Machine learning provides an avenue for developing improved models based on the data generated by high fidelity simulations. In this project, machine learning methods were used to predict when current RANS models would fail. They were also used to develop improved RANS closure models. A key aim was developing a tight feedback loop between scientific domain knowledge and data driven methods. To this end, a methodology for incorporating known invariance constraints into the machine learning models was proposed and evaluated. This work demonstrated that incorporating known constraints into the data driven models provided improved performance and reduced computational cost. This research represents one of the first applications of deep learning to turbulence modeling.

42 ENGINEERING↗

A D-term Modeling Code (DMC) for Simultaneous Calibration and Full-Stokes Imaging of Very Long Baseline Interferometric Data

In this paper we present DMC, a model and associated tool for polarimetric imaging of very long baseline interferometry data sets that simultaneously reconstructs the full-Stokes emission structure along with the station-based gain and leakage calibration terms. DMC formulates the imaging problem in terms of posterior exploration, which is achieved using Hamiltonian Monte Carlo sampling. The resulting posterior distribution provides a natural quantification of uncertainty in both the image structure and the data calibration. We run DMC on both synthetic and real data sets, the results of which demonstrate its ability to accurately recover both the image structure and calibration quantities, as well as to assess their corresponding uncertainties. The framework underpinning DMC is flexible, and its specific implementation is under continued development.

47 OTHER INSTRUMENTATION↗

Bio-project “derisking” through development of systematic methodologies and frameworks for risk assessment

One of the primary hindrances to producing a viable, sustainable domestic biomass industry for renewable biofuels, bio-products and bio-power is the lack of understanding and quantification of the risks associated with both the biomass supply chain and preprocessing and conversion technologies. Currently a consistent method for assessing, comparing, and quantifying risks in biomass supply chains does not exist, creating a major investment barrier to bioenergy projects in the U.S. The lack of a standardized approach has resulted in bioenergy stakeholders independently using inconsistent approaches and evaluation criteria, leading to unreliable and incomparable assessments of risks and financing barriers to bio-project development. Along with the challenges of inconsistent risk assessment for supply chain risk, technology specific risks based on variability in biomass properties are not fully understood and can pose significant unforeseen challenges for bioenergy projects. In many cases these properties have not yet been identified and the impacts on the proposed technology and products unquantified. This is particularly challenging for emerging preprocessing and conversion technologies. Without a firm understanding of the preprocessing/conversion technology-specific critical properties, the risk of a proposed bio-project cannot be fully evaluated. To address inconsistent risk evaluation in the biomass supply chain supporting project financing, a Biomass Supply Chain Risk Standards (BSCRS) framework was developed. The BSCRS framework includes a comprehensive list of known and perceived risks (Risk Indicators) to the supply chain developed through 100’s of interviews with bioenergy industry experts spanning from feedstock growers and suppliers to representatives from the financial sector. These risks have been organized into a manageable hierarchy of Risk Categories and Risk Factors that can be practically assessed. This BSCRS framework also provides mitigation strategies for multiple Risk Indicators from best available industry practices and research findings. Additionally, a risk quantification methodology for each Risk Factor, Risk Category, and the bio-project as a whole was developed to enable capital markets to assess feedstock risk more efficiently and more accurately. Multiple case studies representing existing bio-projects have been used to evaluate and verify the BSCRS framework and scoring methodology. To address technological risk along with the supply chain risk captured in the developed BSCRS framework, this work also focuses on development of a systematic criticality assessment tool using well-accepted, quantitative risk analysis methods to evaluate bioenergy feedstock critical properties impacting system unit operations. The proposed Failure Mode and Effect Analysis (FMEA) approach uses a team of subject area experts (SAEs) for each targeted unit operation within a system. Collectively, the team will develop and use a quantitative scoring system to assess the material attributes, process parameters, and quality attributes for key unit operations that have already been identified. The FMEA process generates Risk Priority Numbers (RPNs) for the various failures and predominant causes for each material/process unit/product combination resulting in a semi-quantitative, standardized methodology for assessing technological risk and biomass properties contributing to that risk.

09 BIOMASS FUELS↗

Multimodel ensemble predictions of precipitation using bayesian neural networks

Multimodel ensembling improves predictions and considers model uncertainties. In this study, we present a Bayesian Neural Network (BNN) ensemble approach for large-scale precipitation predictions based on a set of climate models. BNN infers spatiotemporally varying model weights and biases through the calibration against observations. This ensemble scheme of BNN sufficiently leverages individual model skill for accurate predictions as well as provides interpretability about which models contribute more to the ensemble prediction at which locations and times to inform model development. Additionally, BNN accurately quantifies epistemic uncertainty to avoid overconfident projections. We demonstrate BNN’s superior prediction performance to three state-of-the-art ensemble approaches and discuss its interpretability and uncertainty quantification.

Fan, Patrick↗

Multimodel Ensemble Predictions of Precipitation using Bayesian Neural Networks

Multimodel ensembling improves predictions and considers model uncertainties. In this study, we present a Bayesian Neural Network (BNN) ensemble approach for large-scale precipitation predictions based on a set of climate models. BNN infers spatiotemporally varying model weights and biases through the calibration against observations. This ensemble scheme of BNN sufficiently leverages individual model skill for accurate predictions as well as provides interpretability about which models contribute more to the ensemble prediction at which locations and times to inform model development. Additionally, BNN accurately quantifies epistemic uncertainty to avoid overconfident projections. We demonstrate BNN’s superior prediction performance to three state-of-the-art ensemble approaches and discuss its interpretability and uncertainty quantification.

Fan, Patrick↗

Towards precise and accurate calculations of neutrinoless double-beta decay

We present the results of a National Science Foundation Project Scoping Workshop, the purpose of which was to assess the current status of calculations for the nuclear matrix elements governing neutrinoless double-beta decay and determine if more work on them is required. After reviewing important recent progress in the application of effective field theory, lattice quantum chromodynamics, and ab initio nuclear-structure theory to double-beta decay, we discuss the state of the art in nuclear-physics uncertainty quantification and then construct a roadmap for work in all these areas to fully complement the increasingly sensitive experiments in operation and under development. The roadmap includes specific projects in theoretical and computational physics as well as the use of Bayesian methods to quantify both intra- and inter-model uncertainties. Here, the goal of this ambitious program is a set of accurate and precise matrix elements, in all nuclei of interest to experimentalists, delivered together with carefully assessed uncertainties. Such calculations will allow crisp conclusions from the observation or non-observation of neutrinoless double-beta decay, no matter what new physics is at play.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantification of the Information Limit of Transmission Electron Microscopes

The resolving power of high-resolution transmission electron microscopes is characterized by the information limit, which reflects the size of the smallest object detail observable with a particular instrument. We introduce a highly accurate measurement method for the information limit, which is suitable for modern aberration-corrected electron microscopes. An experimental comparison with the traditionally applied Young's fringe method yields severe discrepancies and confirms theoretical considerations according to which the Young's fringe method does not reveal the information limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Antibody-free, targeted mass-spectrometric approach for quantification of proteins at low picogram per milliliter levels in human plasma/serum

The detection and quantification of proteins at sub-ng/mL concentrations in plasma/serum is of critical importance for candidate biomarker verification. Sensitive detection of serum proteins has typically been achieved by immunoassays; however, de novo development of antibodies is associated with high cost and long lead time. To address this challenge, we developed an antibody-free strategy, termed high-pressure high-resolution separations with intelligent selection and multiplexing (PRISM), for achieving accurate detection of proteins at ~50 pg/mL level in plasma/serum using selected reaction monitoring (SRM). This strategy is based on high resolution reversed phase liquid chromatographic separations for analyte enrichment along with intelligent selection of target fractions via on-line SRM monitoring of internal standards and fraction multiplexing prior to SRM quantification. Our work represents a major technological advance for achieving pg/mL level of serum protein quantification without specific affinity reagents and holds great promise for broad applications in biomarker verification and systems biology studies.

biomarker verification↗

Illuminating Albedo: Using MOSAiC Data to Assess the CERES Cloud Radiative Swath (CRS) Albedo Quantification Process

Increasing surface and lower tropospheric air temperatures as a result of rising greenhouse gases are expected to be most pronounced over the Arctic. Such rapid changes alter the surface climate of the region, and impacts can be observed atmospherically, oceanographically, and biogeophysically. Accurately quantifying the impact of decreasing surface albedo on the surface energy budget with satellite observations alone is complicated by a lack of shortwave radiation during winter and seasonal/spatial heterogeneity of surface type and associated spectral albedo. NASA’s Clouds and the Earth’s Radiant Energy System (CERES) project features the Cloud Radiative Swath (CRS) product, which builds upon the Single Scanner Footprint (SSF) product by using the NASA Langley Fu-Liou radiative transfer model to calculate a robust and high-quality array of surface and atmospheric radiative fluxes on an instantaneous, footprint-level scale. This study aims to use MOSAiC and CRS data to illuminate potential uncertainties in the CERES albedo production process, with goals of determining 1) spectral albedo under clear sky conditions when stratified by ice concentration, 2) the uncertainty associated with CERES surface albedo “history maps” when compared against observations captured during MOSAiC, and 3) the magnitude of variation between meteorological inputs compared to those from MOSAiC.

Emily Monroe↗

BBMap: A Fast, Accurate, Splice-Aware Aligner

Alignment of reads is one of the primary computational tasks in bioinformatics. Of paramount importance to resequencing, alignment is also crucial to other areas - quality control, scaffolding, string-graph assembly, homology detection, assembly evaluation, error-correction, expression quantification, and even as a tool to evaluate other tools. An optimal aligner would greatly improve virtually any sequencing process, but optimal alignment is prohibitively expensive for gigabases of data. Here, we will present BBMap [1], a fast splice-aware aligner for short and long reads. We will demonstrate that BBMap has superior speed, sensitivity, and specificity to alternative high-throughput aligners bowtie2 [2], bwa [3], smalt, [4] GSNAP [5], and BLASR [6].

09 BIOMASS FUELS↗

Uncertainty Quantification of Calculated Temperatures for the AGR-1 Experiment

This report documents an effort to quantify the uncertainty of the calculated temperature data for the first Advanced Gas Reactor (AGR-1) fuel irradiation experiment conducted in the INL's Advanced Test Reactor (ATR) in support of the Next Generation Nuclear Plant (NGNP) R&D program. Recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, the results of the numerical simulations can be used in combination with the statistical analysis methods to improve qualification of measured data. Additionally, the temperature simulation data for AGR tests can be used for validation of the fuel transport and fuel performance simulation models. The crucial roles of the calculated fuel temperatures in ensuring achievement of the AGR experimental program objectives require accurate determination of the model temperature uncertainties. The report is organized into three chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program and provides overviews of AGR-1 measured data, AGR-1 test configuration and test procedure, and thermal simulation. Chapters 2 describes the uncertainty quantification procedure for temperature simulation data of the AGR-1 experiment, namely, (i) identify and quantify uncertainty sources; (ii) perform sensitivity analysis for several thermal test conditions; (iii) use uncertainty propagation to quantify overall response temperature uncertainty. A set of issues associated with modeling uncertainties resulting from the expert assessments are identified. This also includes the experimental design to estimate the main effects and interactions of the important thermal model parameters. Chapter 3 presents the overall uncertainty results for the six AGR-1 capsules. This includes uncertainties for the daily volume-average and peak fuel temperatures, daily average temperatures at TC locations, and time-average volume-average and time-average peak fuel temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uncertainty Quantification of Calculated Temperatures for the AGR-1 Experiment

This report documents an effort to quantify the uncertainty of the calculated temperature data for the first Advanced Gas Reactor (AGR-1) fuel irradiation experiment conducted in the INL’s Advanced Test Reactor (ATR) in support of the Next Generation Nuclear Plant (NGNP) R&D program. Recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, the results of the numerical simulations can be used in combination with the statistical analysis methods to improve qualification of measured data. Additionally, the temperature simulation data for AGR tests can be used for validation of the fuel transport and fuel performance simulation models. The crucial roles of the calculated fuel temperatures in ensuring achievement of the AGR experimental program objectives require accurate determination of the model temperature uncertainties. The report is organized into three chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program and provides overviews of AGR-1 measured data, AGR-1 test configuration and test procedure, and thermal simulation. Chapters 2 describes the uncertainty quantification procedure for temperature simulation data of the AGR-1 experiment, namely, (i) identify and quantify uncertainty sources; (ii) perform sensitivity analysis for several thermal test conditions; (iii) use uncertainty propagation to quantify overall response temperature uncertainty. A set of issues associated with modeling uncertainties resulting from the expert assessments are identified. This also includes the experimental design to estimate the main effects and interactions of the important thermal model parameters. Chapter 3 presents the overall uncertainty results for the six AGR-1 capsules. This includes uncertainties for the daily volume-average and peak fuel temperatures, daily average temperatures at TC locations, and time-average volume-average and time-average peak fuel temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Anticoincidence analysis for radioxenon detection

A number of beta-gamma coincidence detectors have been deployed for monitoring nuclear explosions. When 133Xe is present in a sample it causes interference in the calculation of the metastable isotopes. Therefore, an alternative method for activity quantification is to analyze the anticoincidence spectrum of the plastic detector to decrease interference from 133Xe. Simulated and experimental measurements were tested. The results show that the anticoincidence analysis produces more accurate results when quantifying the activity of 131mXe but is sometimes limited by the background increasing the minimum detectable activity.

Sivels, Ciara B.↗